        USER MANUAL - PAP Heating Solutions
         Contents
1.                 4 events in 7 days       Pra  123458    Selection of type  only visible in type MCD2    Type MCD2 1999 UA has a built in temperature sensor and an externally temperature sensor  In this configuration the thermostat  controls the temperature within the room and use the externally temperature sensor as limit sensor   Type MCD2 can be changed into type MCC2 1991 UA with an external temperature sensor that normally is placed in the floor  construction  In this configuration the thermostat controls the temperature of the floor and not the temperature within the room  MCD2  can also be changed into type MCC2 1999 UA with a built in temperature sensor  In this configuration the thermostat controls the  temperature of the room  and the external temperature sensor should not be installed        oka MCD2 1999 UA With 2 sensors   built in room sensor and incl  floor sensor 3m             MCC2 1991 UA Incl  floor sensor 3m                MCC2 1999 UA With built in room sensor                Max and min allowed temperature range   The temperature setting range of  5   to 40   C can be limited to prevent a too high or too low temperature being selected under manual  or comfort mode  For MCD2 with limit sensor the max and min temperature range refer to the temperature of the limit sensor    For example  A wood floor covering should not be allowed to exceed a maximum of 27  C  Low limitation is used where the temperature  of the floor is required never to fall below the minim
2.             Time and temperature                   4  Advanced settings and read out                            Press both UP  A  and DOWN  V  buttons together for 3 seconds  INFO is displayed   Press UP A  button until you reach the desired sub menu  Select the sub menu with the OK   y   button     Monitoring of energy consumption  The thermostat calculates average time it has been switched on allowing you to monitor your energy consumption   In the thermostat you can read out   Total switch on time in percentage in the latest 2 days  30 days or 365 days   Calculation of operational costs per day   switch on time 100  x kW x kWh price x 24 h per day  Example  Read out  30   in the latest 365 days   Size of heating system  1 2 kW  ask the installer    Cost of power  0 2 USD  kWh   Calculation   30 100  x 1 2 kW x 0 2 USD   kWh x 24 h   1 7 USD per day          2 days          Press UP  A  or DOWN  V  button to show the different  30 days     readouts     365 days                      No changes can be made here  Use the OK   V   button to end              Software version          Actual sensor temperature    4 event sequence   The present event sequence flashes  Days 1 5  followed by days 6 7  To change  press the UP   A  button until you have days 1 6 and  then day 7 flashing  or all 7 days are flashing    Select the required sequence with the OK   y   button          4 events in 5 days      Pr a 2 events in 2 days                   4 events in 6 days    2 events in 1 day  
3. USER MANUAL  Type MCC2 MCD2       57583 08 06    BJ     Product program   This user manual covers following electronic thermostats   MCC2 1991 UA  Incl  floor sensor 3m   MCC2 1999 UA  With built in room sensor   MCD2 1999 UA  With 2 sensors  built in room sensor and incl  floor sensor 3m    Introduction   The thermostat is capable of switching on your heating system at pre determined times on different days of the week  It is possible to set 4 periods   called events each day with different temperatures  From factory a default schedule is programmed suitable for most installations  Unless you change these  settings the thermostat will operate to this default program     Working with lower temperatures during times that the room is unoccupied will lower your energy costs without reducing the comfort  The thermostat has an  adaptive function that automatically changes the start time of a heating period so that the desired temperature is reached at the time that you set  After 3  days the adaptive function has learned when the heating must be switched on     Type MCC2 1991 UA has an external temperature sensor that is normally placed in the floor construction  In this configuration the thermostat  controls the temperature of the floor and not the temperature within the room    Type MCC2 1999 UA has a built in temperature sensor  In this configuration the thermostat controls the temperature of the room    Type MCD2 1999 UA has a built in temperature sensor and an externally temp
4. election of type  will return to a  MCD2  Failure code E2 will be displayed if the external sensor has been removed        Factory settings           4 event time and temperature         ne       Time    es  55  C 5  C    06 00    08 00    16 00          08 00    23 00    Day 1 5  Day 6 7    Adaptive control ON    6  Failure codes        EO   Internal failure  replace thermostat  E1   Built in sensor short circuit or disconnected  replace thermostat  E2   External sensor short circuit or disconnected    OJ ELECTRONICS A S   Stenager 13B   DK 6400 S  nderborg   Tel   45 73 12 13 14  Fax  45 73 12 13 13  oj oj dk   www oj dk     gt  7583    
5. erature sensor  In this configuration the thermostat   controls the temperature within the room and use the externally temperature sensor as limit sensor avoiding to high or to low temperatures in the floor  construction     The thermostat has a pin button marked R  allowing you to reset the thermostat to factory settings  These are listed at the end of this manual with space for  you to record your own weekly schedule     The display is backlit when operating the buttons  The heating element is switched off when the light is on in the display    The heating system can be switched off on the built in interrupter  The Microprocessor taking care of the time will still be supplied with power whereby time  and day will be maintained  When the heating is required and the thermostat is switched on  it will continue the 4 event programme based on present time  and day     1  Getting started  Buttons Display symbols    BR929B05       Pin button   On off Reset to Adjustment Time and Day number  adjust of factory down j temperature  clock setting    OK   Adjustment   Display Heating on 4 event symbol  accept up Monitoring Xt Wake O   Out  of switch on    time C Night   Home       Setting the thermostat into operation    First time power is connected the clock and day will be flashing and must be set  If you need to  adjust the time of the thermostat at a later date  insert a pin into the hole    for setting of time  and day  Adjustment must be made for summer and winter time        Pre
6. ss the UP  A  or DOWN  V  buttons to  select the correct time and press OK button  vV             Then press the UP  A  or DOWN  V  button to  select the correct day and press OK   V   button           343  123450       Type  MCC2 MCD2    2  Daily use of the thermostat   4 event clock mode   The day has been split into 4 events describing a typical day  When the thermostat is in 4 event mode it will automatically adjust the temperature according  to the required temperature to the required time  As standard the thermostat has 5 days with 4 events  and 2 days with 2 events  Programming see 3        4 event clock mode     The clock function symbol        and one of the 4 event symbols   AOAC   will be indicated   Programming see 3           Comfort mode            X 5 Secs              Temporary override  To temporarily override the temperature in the 4 event schedule program  press the UP  4  or DOWN  V   button  once  to show the temperature  and press again to increase or decrease the temperature  The display will flash for    5 seconds  and will then revert to the time  The override will operate until the next programmed event when the  unit will resume the automatic programme        Cancel comfort mode  To cancel the override state  press the OK   Y   button twice           Manual mode     w  AV X 5 secs     Permanent override    During holidays  the scheduled 4 event program can be overridden    Press the OK   V   button  and then the UP  A  or DOWN  V  button until the o
7. um set temperature     Maximum allowed temperature setting  Use the UP  A  or  DOWN  V  button to increase or reduce  and OK   v   button to  accept     Next is displayed LoLi  Press OK   V   button to continue   Minimum allowed temperature setting  Use the UP  A  or    DOWN  A  button to increase or reduce and OK  V   button to  accept                          You can select either   C or F scale  and 12 or 24 hour clock as  follows              Press UP  A  or DOWN  V  button to change settings  Confirm    the required scale with the OK button   v   button        to be continued        4  Advanced settings and read out   continued    Adaptive function    This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set  time  With a start time of 07 00 therefore  the thermostat may switch ON as early as 06 00 so that the desired temperature of 25  C is  achieved by 07 00  Without this function set  the thermostat will start to heat at the time you set     Press the DOWN  V  button to switch between on and off        Press OK  V   button to confirm                 Press OK  V   button to end programming and to return to  scheduled programme              Press the pin button and the thermostat returns to factory settings  Time and day is also reset and must be set according to  Setting the  thermostat into operation      Note that a MCD2 that has been modified to a MCC2  see 4  Advanced settings and read out  s
8. verride temperature is set   The unit will now operate to this temperature permanently                 Cancel manual mode  To cancel the permanent override state press the OK   V   button once  and the unit will resume automatic function              3  Programming    Press OK   V   button for 3 secs  to begin programmin  4 event time and temperature  Vv  bu gin prog Ing    37    Time and temperature    For each event  the start time and required  temperature must be set           For example  in the morning you wish the heating to  start at 07 00 and the temperature to rise to 25  C   Press OK   Y   button for 3 seconds and the start time  is displayed  Change this to 07 00 with the   UP  A   or DOWN   V   button  Press OK  Y   to  confirm    The temperature is now displayed  Change this to  25  C with the UP  4   or DOWN   V   button    Press OK   v   button to confirm  This action can now  be repeated for the second event                       Time and temperature                 Time and temperature               Time and temperature    These settings will be valid with days 1 5 showing on  the display  To program the days 6 and 7  repeat the  above  Days 6 and 7 are usually Saturday and  Sunday  and only have two events                             The temperature can be set within the range of  5 to   40  C  It is also possible to select the heating OFF at  that event by reducing the setting to 5  C  and then  pressing the   V   once more     3    Time and temperature   
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
User Manual - glasnost.itcarlow.ie  Muvit MUEAF0142 mobile phone case      Guida dell'utente  Anschlüsse und Bedienelemente  DMX-512 LED CONTROLLER  Handheld Vacuum Sealer model VS  informativo de licitações e contratos tribubal de contas da união  一般競争入木L公告 (再度公告)    Copyright © All rights reserved. 