Contents

1. Door Door Door Office A Office B Office C Office A Office B Office C Office A Office B Office C AREA 1 AREA 2 AREA 3 AREA 1 AREA 2 AREA 3 AREA 1 AREA 2 AREA 3 Common Area remains Disarmed Common Area remains Disarmed Common Area automatically Arms All Areas are Armed Area 2 Disarms Area 3 Disarms and so on Entrance Entrance KEYPAD Entrance KEYPAD COMMON AREA Entry COMMON AREA Entry COMMON AREA Entry Door Door Door Office C Office C 3 3 Common Area automatically The Common Area remains Disarmed Disarms until all Areas are again Armed 08 NESS D24 CONTROL PANEL USER MANUAL AREA CODES TO ARM YOUR AREA Most users of the panel should be assigned Area Codes An Area Code allows you to Arm and Disarm only the Area which has been assigned to that code This makes Area operation as simple as possible with the least number of keystrokes Press 6008 CE Three beeps will sound ddd and your AREA icon will turn ON apex anco Leave the Area within the Exit Delay Time At the end of Exit Delay Time 1 beep will sound 4 SHORTCUT ARMING IS ALLOWED FOR AREA CODE ARMING TO DISARM YOUR AREA To Disarm the Area assigned to your code simply enter your code follo
2. Disarm the panel during the Entry Delay Time to prevent unwanted Alarm on entry An error beep when attempting to Disarm may indicate Incorrect Code or the panel is already Disarmed or the panel is in Exclude mode See Page 12 for Disarming Areas NESS D24 CONTROL PANEL USER MANUAL 197 AREA OPERATION AREA OPERATION DEFINITION Area Operation allows the 24 zones to be split into three Areas The panel then effectively operates as three separate systems sharing only the siren outputs and dialler The three Areas can either share one keypad or operate from multiple keypads USER CODES OPERATION Areas can be operated by users holding Area Codes or Administrator Codes AREA CODES are User Codes which are programmed to operate one Area only ADMINISTRATOR CODES are User Codes which can operate any Area COMMON AREA OPERATION The Common Area refers to a zone or zones that have been assigned to more than one Area The Common Area is used in cases where the requirement is for a zone s to automatically Arm or Disarm depending on the state of the overlapping Areas The Common Area behaves as follows When Areas are Armed the Common Area automatically Arms When any Area has Disarmed the Common Area automatically Disarms EXAMPLE COMMON AREA OPERATION Area 1 is Armed Area 2 is Armed Area 3 is Armed Entrance KEYPAD Entrance KEYPAD Entrance KEYPAD COMMON AREA Entry COMMON AREA Entry COMMON AREA Entry
3. Press and hold for at least 1 second or C XD E If Two Button Keypad Operation is enabled DURESS ALARM A DURESS alarm can be triggered to alert the Central Monitoring Station that you are being forced to Disarm the panel against your will To Disarm and simultaneously send a DURESS alarm prefix your User Code with the Duress Digit when Disarming The factory default Duress Digit is 9 It can be any number from 0 9 Disarm by pressing Duress Digit CODE E By default DURESS alarms do not sound any audible alarms unless programmed to do so by your installer Duress alarm is number 5 in the s srt view The panel Disarms as normal and the Duress report is sent to the Central Monitoring Station IF DURESS ALARM IS USED AVOID USER CODES THAT BEGIN WITH THE SAME NUMBER AS A DURESS DIGIT DURESS ALARM CAN ONLY USED IF YOUR SYSTEM IS MONITORED BY A CENTRAL STATION us NESS D24 CONTROL PANEL USER MANUAL EMERGENCY ALARMS MEDICAL ALARM Your system may have been setup with a Medical Alarm This type of alarm can be used to summon assistance for the elderly or infirm who are living alone A Medical Alarm is most effective if the system is monitored by a Central Monitoring Station Medical Alarms can be used in two ways 1 INSTANT MEDICAL ALARM Immediately sound the sirens and send a Medical Alarm report to the Central Monitoring Station In this case the Medical Alarm Delay
4. ENTRY DELAY TIME Entry Delay Time applies to Delay Zones and gives you time to enter the premises and Disarm without causing an alarm When a Delay zone is triggered the panel will go into alarm state if it is not Disarmed within the Entry Delay time The Entry Delay Time can be programmed in the range of 1 to 99 seconds To Program Entry Delay Time P CD C2 CE tt 99 E Example Programming the Entry Delay Time to be 35 seconds 1 Press P Q 7 E 2 The existing Entry Delay Time is displayed 3 Press 3 5 E Enters the new time EXIT DELAY TIME On Arming the panel Exit Delay Time gives you time to leave the premises without causing an alarm Exit Delay Time applies to all zones except 24 hour zones The Exit Delay Time can be programmed in the range of 1 to 99 seconds To Program Exit Delay Time P C 8 CE 1 99 CE Example Programming the Exit Delay Time to be 90 seconds 1 Press P 1 2 The existing Exit Delay Time is displayed 3 Press 9 0 E Enters the new time E NESS D24 CONTROL PANEL USER MANUAL NESS ACCESSORIES NESS QUANTUM DETECTORS The Ness Quantum range of high tech motion detectors includes passive infrared detectors dual technology microwave and infrared as well as ceiling mounted 360 detectors All Ness detectors are designed and manufactured using the most modern technology and techniques to ensure superior reliabil
5. SIREN A Tone 2 SIREN B Tone 2 KEY INDICATOR OUTPUT 1 1 SIREN A Tone 1 2 2 SIREN B Tone 1 3 3 RESET internal screamer 4 4 STROBE 5 5 AUX 1 6 6 AUX 2 7 7 KEYPAD BEEPS 8 1 9 2 20 NESS D24 CONTROL PANEL USER MANUAL PROGRAM OPTIONS TABLE FACTORY OPTION OPTION No DEFAULT RANGE PROGRAMMED User Code 1 Master Code P1E 3 to 6 digi User Code 2 P2E 3 to 6 digi User Code 3 P3E 3 to 6 digi User Code 4 P4E 3 to 6 digi User Code 5 P5E 3 to 6 digi User Code 6 P6E 3 to 6 digi User Code 7 P7E 3 to 6 digi User Code 8 3 to 6 digi User Code 9 3 to 6 digi User Code 10 3 to 6 digi User Code 11 3 to 6 digi User Code 12 3 to 6 digi User Code 13 3 to 6 digi User Code 14 3 to 6 digi User Code 15 3 to 6 digi User Code 16 3 to 6 digi User Code 17 3 to 6 digi User Code 18 3 to 6 digi User Code 19 3 to 6 digi User Code 20 3 to 6 digi User Code 21 3 to 6 digi User Code 22 3 to 6 digi User Code 23 3 to 6 digi User Code 24 3 to 6 digi User Code 25 3 to 6 digi User Code 26 3 to 6 digi User Code 27 3 to 6 digi User Code 28 3 to 6 digi User Code 29 3 to 6 digi User Code 30 3 to 6 digi Entry Delay Time 20 seconds 1 to 99 sec Exit Delay Time 60 seconds 1 to 99 sec NESS D24 CONTROL PANEL USER MANUAL E PROGRAMMING PROGRAM MODE Various system options can be programmed by the user These options can only
6. and a number to indicate the type of alarm 2 In normal idle mode system is disarmed with the E icon displayed the memory history can be displayed in sequence To view the Memory History Press IEW ML E the umo icon will turn on Then press CVIEW2 Repeat presses At each step the keypad icons will display past events The Zone Tamper System and Power icons will indicate what type of events are being displayed Memory is displayed backwards from most recent event to the end of memory The past 50 events are stored Press Oro exit the Memory menu MEMORY MODE EVENTS INDICATED BY KEYPAD ICONS ICON EVENT M Events are from memory MEMORY Zone alarms zone and 1 24 flashing T Tamper alarms TAMPER and 1 5 and 1 8 System alarms power and 1 0 Power alarms A 88 and 1 24 flashing Fire Zone alarm Arm ARM Disarm ZONE 8 Monitor Mode montor Slow flash Area 1 Arm AREA1 2 Area 2 Arm AREA 2 Area 3 Arm AREA1 slow flash Area 1 Monitor Mode AREA2 Slow flash Area 2 Monitor Mode Also see Keypad Display Table page 6 NESS D24 CONTROL PANEL USER MANUAL MEMORY VIEWING EXAMPLES Examples of how to view Memory and the types of events that might be shown Panel is Disarmed All zones are sealed Most recent event Zone 2
7. alarm Excluded PROGRAM User Program Mode 7 TEST Normal Siren Test a NESS D24 CONTROL PANEL USER MANUAL VIEW MENU OPERATION TAMPER ALARMS To view 1 External Tamper TAMPER 2 Control Panel Tamper alarms 3 Zone input Tamper 2 5 Radio Interface Tamper SYSTEM ALARMS To view 1 Keyswitch Panic SYSTEM 2 Dialler line fault ate 3 Keypad connection fault 4 Control Panel fault 5 Duress alarm 6 Panic alarm 7 Medical alarm 8 User Code alarm 9 Access to Installer Program mode alarms 3 DC supply failed 4 Zone reference supply failed Cue D 9 Radio Device battery low 1 8 shows which device has low battery 0 Radio Key battery low 1 8 shows which device has low battery To view MEMORY MEMORY DISPLAY u MEMORY icon flashes to indicate that Memory contains new events Memory can be viewed at any time 1 Press Cuew E 2 M Memory icon turns on Keypad icons will display the POWER ALARMS To view 1 Mains power failure POWER 2 Backup Battery low most recent event as per the Keypad Display Table 3 Step through the Memory display by pressing the e gt button At each step the keypad icons display the history of Arming Disarming and alarm events Press E to cancel the Memory display at any time NESS D24 CONTROL PANEL USER MANUAL E OPERATION ARMING AND DISARMING The Ness D24 micro computer based 24 zone control panel is the hea
8. THE SYSTEM If the D24 has not been programmed for Area operation this method will Arm the entire system Press If Two Button Keypad Operation is disabled This is the factory default r E If Two Button Keypad Operation is enabled r CODE E if Shortcut Arming is disabled Three beeps will sound ad and the ARM icon will turn ON f Leave the premises within the Exit Delay Time At the end of Exit Delay Time 1 beep will sound J The control panel must be Armed prior to vacating the premises in order to detect intruders Ensure that the panel is not in Program Memory or Exclude modes Note If the panel is already in alarm you must first silence the alarm before you can Arm SIREN WARNING At the end of the exit time all zones should be Sealed If any are Unsealed the siren will sound for 2 seconds as a warning to indicate DISARMING THE SYSTEM that those zones have been automatically excluded For maximum security you should return Disarm check the premises and then Arm again Continual warnings could mean that a detector is faulty and may have to be manually excluded AUTO EXCLUDE If the auto exclude option is disabled the siren will sound for the duration of reset time if a zone is Unsealed at the end of exit time If the D24 has not been programmed for Area operation this method will Disarm the entire system CODE E Press Three beeps will sound ddd and the ARM icon will turn OFF
9. in areas where it is not possible to install wires Includes long life lithium battery The Ness R15PET Pet Aware model detects humans but is immune to household pets Allows you to protect your home with your pets inside RADIO SMOKE DETECTOR j The Ness Radio Smoke Detector provides a fully wireless smoke detection option which can trigger the panel s siren s and dialler if required or as programmed by your installer The Ness Radio Smoke Detector uses Photo electric smoke detection technology On board sounder and test button for the sounder and radio transmitter A single battery powers the smoke detector and the transmitter Includes 9V lithium battery NESS D24 CONTROL PANEL USER MANUAL INSTALLATION RECORD Date purchased Date installed D 24 Installation Company DIALER SECURITY ALARM PANEL Telephone NESS D24 mE ALARM CONTROL PANEL Monitoring Company Telephone ZONE LIST DEVICE TYPE DESCRIPTION Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 Zone 17 Zone 18 Zone 19 Zone 20 Zone 21 Zone 22 Zone 23 Zone 24 NOTES NESS D24 CONTROL PANEL USER MANUAL 27 OPERATION SUMMARY To ARM or Can E 0r 6008 E To DIS
10. is set at zero hours 2 INACTIVITY MEDICAL ALARM The Medical Alarm is reported if the Medical Alarm button is NOT pressed within the pre programmed Medical Alarm Delay In this case the Medical Alarm Delay is set between 1 and 24 hours INSTANT MEDICAL ALARM OPERATION 1 If the Medical Alarm Delay is not being used simply press the designated Medical Alarm button 2 If the Medical Alarm Delay is being used an instant Medical Alarm can be sent by pressing the button twice within 12 seconds On the first FIRE ALARM Your system may have smoke detectors connected to 24 hour Fire inputs If Fire inputs are enabled the alarm indication is by the Fire icon on the keypad FIRE press the keypad s will beep once per second during the 12 second period On the second press the keypad s will beep fast to indicate that the Medical Alarm has been reported INACTIVITY MEDICAL ALARM OPERATION The Inactivity Medical Alarm can be used to summon assistance if a person has become incapacitated and is not able to press their Medical Alarm button For example if the Medical Alarm Delay is set for 24 hours the Medical Alarm will be triggered if the button is not pressed every 24 hours Effectively it is an I m button When 20 minutes of the Medical Alarm Delay time remains and the Medical Alarm button has not been pressed the keypad s will beep for 10 Seconds as a reminder As a final warning that t
11. ANEZSZ 324 CORPORATION DIALLER SECURITY ALARM PANEL D 24 CONTROL PANEL AND DIALLER MADE AUSTRALIA uU USER S MANUAL Revision 2 tive Electronic Soluti wewneesomau Fw CORPORATION Ness Corporation Pty Ltd ABN 28 069 984 372 Private Bag 23 Seven Hills NSW 1730 Australia Ph 61 2 8825 9222 Fax 61 2 9838 8508 Email ness ness com au SYDNEY D24 USER MANUAL Ph 02 8825 9222 sales ness com au REVISION 2 MARCH 2012 MELBOURNE Document Part No 890 252 Ph 03 9875 6400 nessmelb ness com au For the product 100 660 D24 Control Panel BRISBANE Ph 07 3399 4910 nessbris ness com au PERTH Ph 08 9328 2511 nessper ness com au N55 MADE ADELAIDE VA C AUSTRALIA Ph 08 8152 0000 adelaide ness com au WARNINGS amp NOTICES Ness Corporation manufacturing processes are accredited to ISO9001 quality standards and all possible care and diligence has been applied during manufacture to ensure the reliable operation of this product However there are various external factors that may impede or restrict the operation of this product in accordance with the product s specification These factors include but are not limited to 1 Erratic or reduced radio range if radio accessories are installed Ness radio products are sophisticated low power devices however the presence of in band radio signals high power transmissions or interference caused by electrical appliances such as Mains Inverters Wireless R
12. ARM or reset alarms CODE E To Arm MONITOR mode o Gema E OF 6008 E To exit MONITOR mode CODE E To EXCLUDE zones CODE or die E then ZONE NUMBER E ZONE NUMBER E Up to 24 zones To exit EXCLUDE mode E PANIC alarm Press and hold for 1 second CX E VIEW menu VIEW Repeat presses Cycles viewing ot 1 menus ZONE TAMPER SYSTEM POWER MEMORY To exit VIEW mode Reverts to normal view 122 NESS D24 CONTROL PANEL USER MANUAL
13. DE POWER ALARMS Press 4 E e and Q will be on POWER NUMBER elc The selected Power numbers will turn on TO EXIT EXCLUDE MODE Press E will flash while Disarmed and Armed EXCLUDE NESS D24 CONTROL PANEL USER MANUAL 19 AUTOMATIC ZONE TEST TEST MODE This is an option that helps avoid the situation of azone sensor going faulty or being disconnected without it being noticed When Automatic Zone Test is enabled by your installer a count is kept of the number of times the panel is Armed and Disarmed Any zone which has failed to detect anything over the past 20 Armings is recorded and the indicator also lights up To find out which zones have been dormant Press EW 7 or 7 CE If Two Button Keypad Operation is enabled The zone indicators show which zones need to be checked To do this walk test the zones in question The zone indicators which were on should now be flashing Any which are still on and not flashing need to be checked by a service person To exit View test Press IEW E Test Mode allows the user to manually test all audible and visual outputs without alarming the panel Press CODE E The test icon will turn on Press the keys below to operate each output Press the same key to turn the output off Pressing any other key will test that output and cancel the current output Press E To exit Test Mode
14. NESS D24 CONTROL PANEL USER MANUAL 024 KEYPAD 7 8 15 16 23 24 A M MONITOR AREA AREA2 AREAS EXCLUDE PROGRAM TEST QD Lol 2 8 9 OE 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 16 19 20 21 22 23 24 OD BACKLIT ARM ZONE TAMPER SYSTEM POWER FRE MEMORY 2 LCD ICON win E RES rcu dir DISPLAY PANIC BUTTON Press amp Hold PROGRAM BUTTON ENTER BUTTON KEYPAD DISPLAY TEST Press and hold E button NESS D24 CONTROL PANEL USER MANUAL 1 24 ZONES KEYPAD DISPLAY TABLE OFF Zone sealed Zone unsealed Flashing FAST Zone Alarms present in Armed or Monitor Mode Flashing SLOW f ARM Panel is Disarmed Panel is Armed ZONE Displaying Zone Status T TAMPER Displaying individual Tamper Alarms Tamper Alarms present Displaying individual System Alarms System Alarms present Normal Displaying individual Power Alarms Power Alarms present Normal Fire warning If enabled Fire alarm If enabled MEMORY Memory Mode or View key pressed New alarm in Memory MONITOR Panel is in Monitor Mode 1 AREA 1 Area 1 Armed Area 1 Monitor 2 AREA 2 Area 2 Armed Area 2 Monitor 3 AREA 3 Area 3 Armed EXCLUDE Exclude Mode Zone or other
15. RM AREA1 AREA2 AREA3 22 NESS D24 CONTROL PANEL USER MANUAL PROGRAMMING CODES ADMINISTRATOR CODE An Administrator Code is able to Arm and Disarm all Areas of a Partitioned system but it is not allowed entry to Program Mode Programming is the same as an Ordinary Code To Program an Administrator Code P INN CE CODE CODE E 3 icons will be ON The ARM AREA1 AREA2 AREA3 AREA CODE An Area Code is a code which only has access to the Area assigned to that code The user does not need special instructions for Arming and Disarming ARM CODE E Arms only the assigned Area CODE E Disarms only the assigned Area See page 11 for details To Program an Area Code assigned to AREA1 PJINNI CE 1 CE CODE E CODE E The icon will be ON AREA 1 To Program an Area Code assigned to AREA2 P inn CE 2 CE CODE CE CODE E The 5 icon will be ON To Program an Area Code assigned to AREA3 P inn CE 3 E CODE E CODE E The icon will be ON MASTER CODE A Master Code is able to Arm and Disarm all Areas of a Partitioned system and is allowed entry to Program Mode User Code 1 is always a Master Code but all other codes can be programmed as Master Codes To Program a Master Code P inn CE 0 E CODE CODE icons will be FLASHING The ARM AREA1 AREA2 AREA3 NESS D24 CONTROL PANEL USER MANUAL a PROGRAMMING TIMERS
16. W ZONES ZONE Press EW 1 The zone indicators 1 24 will show the state of the 24 zones and possibly one or more other icons flashing to indicate other alarms TO VIEW TAMPERS TAMPER Press EW 2 Zone indicators will show the state the four Tamper inputs TAMPER 1 External Tamper TAMPER 2 Control Panel Tamper TAMPER 3 Zone Input Tamper TAMPER 5 Radio Interface Tamper VIEW SYSTEM SYSTEM Press EW 3 Zone indicators will show the state of the eight System inputs SYSTEM 1 Keyswitch Panic SYSTEM 2 Dialler line fault SYSTEM 3 Keypad connection fault SYSTEM 4 Control panel fault SYSTEM 5 Duress Alarm SYSTEM 6 Panic Alarm SYSTEM 7 Medical Alarm SYSTEM 8 User Code Alarm SYSTEM 9 Access to Installer Program mode D TO VIEW POWER POWER Press EW 4 Zone indicators will show the state of the six Power alarms POWER 1 Mains power failure POWER 2 Control panel backup battery is low POWER 3 DC supply failure POWER 4 Zone reference power failure POWER 9 Radio device battery low Zone indicators 1 8 will show which device POWER 0 Radio Key battery low Zone indicators 1 8 will show which Radio Key 16 NESS D24 CONTROL PANEL USER MANUAL VIEW MEMORY HOW TO VIEW MEMORY 1 When the icon is flashing to indicate there is anew alarm in memory pressing VIEW will display an icon for example Zone Tamper System etc
17. alarm M MEMORY Next most recent event Panel was Armed T M ARM MEMORY Next most recent event D Mains power failure MEMORY Press CVIEW2 EE tc Up to 50 events in memory Press E to exit Memory mode 18 NESS D24 CONTROL PANEL USER MANUAL EXCLUDE Zones and other inputs can be Excluded so Zone Exclude IS not permanent Excluded zones that it does not generate alarms EXCLUDE isa are automatically INCLUDED next time the panel method of temporarily disabling an input is Disarmed When zones have been Excluded the EXCLUDE Zones can be manually included by the same icon flashes continuously while the panel is method as Excluding In Exclude mode simply Disarmed and also when Armed use the NUMBER E sequence to turn OFF the zone lights to be Included Zones can only be Excluded when the panel is Disarmed TO ENTER EXCLUDE MODE Press cope E OF If Shortcut Exclude is enabled TO EXCLUDE ZONES uve and zone will be Press ZONE NUMBER ZONE NUMBER elc The selected Zone numbers will turn on TO EXCLUDE TAMPER ALARMS Press 2 E and ie will be on TAMPER NUMBER et The selected Tamper numbers will turn on TO EXCLUDE SYSTEM ALARMS Press 3 E and A will be on SYSTEM NUMBER etc The selected System numbers will turn on TO EXCLU
18. be accessed from User Program Mode User Codes 1 to 30 Entry Delay Time Exit Delay Time For all other programming changes talk to your installer The panel will automatically exit User Program Mode is no buttons are pressed within a one minute period TO ENTER PROGRAM MODE Press P tmaster CODE TO EXIT PROGRAM MODE Press P then E INN The Option Number of the code being programming PROGRAMMING USER CODES User codes are the PI N codes used to operate various panel functions especially Arming and Disarming There are 30 User Codes and each can be 3 to 6 digits long User Code 1 is always the MASTER CODE User Codes 2 to 30 can be programmed to any of these types ORDINARY DISABLED ADMINISTRATOR AREA When programming codes the User Code type is displayed by the icons xa amo am If User Code 1 was used to enter Program Mode the digits of any existing codes will be displayed when programming a User Code ORDINARY CODE An Ordinary Code is for systems configured without Areas Allows full access to the panel except for entry to Program Mode To Program an Ordinary Code P NN CE CODE CE CODE The ARM AREA1 AREA2 AREA3 icons will be ON DISABLED CODE Any Code except the Master Code can be taken out of service by programming its first digit to be zero To Disable a Code P Inn CE CO cove E 0 cove E 3 icons will be ON The A
19. eatures and specifications at any time without prior notification in the interest of ongoing product development and improvement 2012 Ness Corporation Pty Ltd ABN 28 069 984 372 CONTENTS iul C ei 4 Met Nut deed 5 Keypad DISplay Table rt ote 6 View Menu Operation centnm een teen 7 OPERATION tec 8 9 9 5 9 AREA Opera UON ar rettet ret tec rte a e 10 Arming Disarming 635 11 Administrator Code Monitor Modes tret rens Panic Alani 14 Duress Alani edi aa 14 Medical 15 EIFG AMAT 15 tte tecta 16 VIEW MEMOR ecce rt crt Pr entes 17 Excluding ZONES 19 uno 20 Sirem Te 21 PROGRAMMING Programming Options Table sse 21 Howto PRO ORAM e hne ees 22 User Code programming nnne 22 23 Entry Exit Timer programming nnene 24 WirelesS ACCBSSOTIBS ccrte teeth tet tet eet eerie 25 Installation ROC ONG cic ceme
20. ed to monitor perimeter zones doors and windows while you are at home Your system may be programmed to give the choice of Arming two different Monitor areas Dual Monitor mode otherwise there is one Monitor area Single Monitor mode ALARM TYPES IN MONITOR MODE Monitor mode alarms can be programmed to trigger a number of different combinations of siren strobe dialler and other alarms ARMING SINGLE MONITOR MODE or E or icone E Press ARMING DUAL MONITOR MODE Press 1 MONITOR 2 OF D E OF 2 E The most common configuration which is also the factory default triggers the keypad sonalert beeper as well as a siren burst ZONES MUST BE SEALED Make sure that all zones in the Monitor area are sealed before Arming Monitor mode EXIT DELAY The Exit Delay time applies to Monitor mode NESS D24 CONTROL PANEL USER MANUAL ie EMERGENCY ALARMS PANIC ALARM The keypad panic function may have been programmed to be either Audible Activates siren or buzzers or Silent If your system is monitored by a Central Station sends a Panic report by dialler If Panic reports have been enabled by your installer Press Panic cannot be used while the panel is in Program Memory or Exclude mode Note Your installer may have installed a separate panic button To activate the panic alarm simply press that button Keypad Panic alarm is number 6 in the 15 view
21. he Medical Alarm delay is due to expire the keypad s will beep continuously during the final 10 minutes MEDICAL ALARM BUTTON The Medical Alarm button can be setup to take the place of the keypad Panic button or it may be a separate button This must be determined by your installer Medical alarm is number 7 in the s sre view Fire inputs may be programmed to sound sirens or report alarms if your system is monitored by a Central Monitoring Station or other actions as setup by your installer NESS D24 CONTROL PANEL USER MANUAL 15 VIEW MENU The VIEW menu can be used at any time to display the status of Zone Tamper System and Power inputs The status of these inputs can be displayed live as it happens or as a previous event in Memory mode EW TO VIEW A CURRENT ALARM Tj i For example if the r icon is flashing indicating that a Tamper alarm is present Press the MEMORY and Tamper icons will be on and a number will indicate which TAMPER alarm is present TO VIEW THE STATUS OF ALL ALARMS Press Repeat presses Repeated presses of the VIEW button will cycle viewing of Zone Tamper System Power and Memory sub menus Or each sub menu can be directly viewed by pressing CVIEW 1 6 DEFAULT VIEW The display always shows the zone menu by default It will automatically revert back to the ZONE menu after eight seconds if left in any other view menu TO VIE
22. ity and performance amp SIRENS The range of warning devices includes horn speakers polytough siren covers internal screamers and satellite sirens with their own battery backup NESS CCTV PRODUCTS The wide range of Ness CCTV equipment allows your installer to design a professional state of the art system for your home office shop or factory For safety and security Ness CCTV provides solutions for all video surveillance needs with a wide range of quality DVRs cameras and accessories Ness IP based CCTV solutions integrate seamlessly into today s online lifestyle SWITCHES A variety of switches are available for protecting doors and windows The line up includes surface and flush mount reed switches emergency buttons roller door reed switches and the unique Nessensor vibration sensor for highly effective perimeter protection NESS D24 CONTROL PANEL USER MANUAL EJ NESS WIRELESS PRODUCTS OPTIONAL RADIO ACCESSORIES Ask your installer about the range of Ness radio devices for the optional extra convenience of wireless remote control and wireless detection Operating your Ness security system can be as convenient as opening your car door Ness Radio Keys provide the benefits of separate ON OFF and PANIC buttons as well as optional control of auxiliary outputs all in a slim waterproof remote control Ness radio products require a Ness Radio Interface 100 200 to be fitted to
23. outers Cordless Phones Computers TVs and other electronic devices may reduce radio range performance While such occurrences are unusual they are possible In this case it may be necessary to either increase the physical separation between the Ness receiver and other devices or if possible change the radio frequency or channel of the other devices 2 Unauthorised tampering physical damage electrical interruptions such as mains failure electrical spikes or lightning 3 Solar power inverters are a known source of electrical interference Please ensure that this product and all associated cabling is installed at least 3 metres away from a solar power inverter and its cabling WARNING Installation and maintenance to be performed only by qualified service personnel CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries in accordance with local regulations ADSL NOTICE ADSL broadband data can interfere with the operation of your alarm dialler It is recommended that a quality ADSL filter be installed as per the filter manufacturer s guidelines in premises with an alarm dialler installed COPYRIGHT NOTICE rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to f
24. re intrent rn alia tem Operation Summary NESS D24 FEATURES e Powerful multizone commercial secu e Outputs are separately fused with rity Automatic Reset Fuses e 24 fully programmable zones e Day Mode and Door Chime feature e Supports 8 Radio Devices Radio e 30 Event Memory PIRs Radio Reeds etc e inputs and outputs are heavily e Supports 8 Radio Keys protected against lightning and high voltage supply transients An earth e Contact ID Dialler Format terminal is provided for extra protec tion e Ness Audible Dialler Format e 30 User Codes e Separate 24 Hour Tamper input e Programmable Inputs to activate Single or Double Trigger Zones selectable Outputs Output Mapping Remote LCD Keypads Max 3 Manufactured with the latest SMD Technology e Fully programmable via the system Keypad Eliminates the need for e Ultra Modern and Impact resistant expensive programmers or Proms Housing Inbuilt Vibration Sensor Analyser e Forced Arming Feature e All programming data is perma nently stored in a non volatile EEprom memory e True Dynamic Battery Test every time the Panel is Armed Disarmed and every hour Area Partitionable 3 Areas Any Zone can be programmed to any area as well as common areas e Comes complete with an AC plug pack and supports a 12V 7Ah battery to maintain system security under all power supply conditions e Two separate Monitor Modes Home Mode 2
25. rt of your security system to which all your detection devices connect Each Zone of the panel can be connected to one or more detection devices to protect separate rooms of your premises Detection devices may be connected to the D24 control system directly by cabling or with optional wireless Radio devices The most common type of detection devices are Passive Infra Red Motion Detectors or 5 for short and Reed Switches for doors and windows OPERATING MODES The Ness D24 will operate in one of the following modes ARMED The system is On and ready to detect intrusion 24 Hour Zones if configured are still active Area Partitioning means the panel can be split into three separate Areas which can be Armed and Disarmed independently of each other DISARMED The system is Off This is the normal mode when the premises are occupied Day Zones and 24 Hour Zones if configured are still active DAY Mode The system is Disarmed and a zone or zones have been setup to create an alarm when activated Often used as a doorway alert in a shop MONITOR Mode Allows the system to be partially Armed For example in a house to allow all perimeter zones doors and windows to be Monitored armed at night 2488 Zones Zones that have been setup to be active in any mode Usually used for Tamper Switches and Panic buttons EN NESS D24 CONTROL PANEL USER MANUAL ARMING amp DISARMING ARMING
26. the control panel RK4 RK3 Radio Key Radio Key RADIO KEYS Fully waterproof ultra slim 3 or 4 button Radio Keys for remote control of the control panel With separate buttons for ON Arm OFF Disarm PANIC and AUX functions RK4 only Including long life lithium battery RADIO KEY PENDANT Fully waterproof pendant style transmitter can be used as a portable wireless Panic button Supplied with a neckchain as well as wristwatch straps Ideal for use as a medical alarm for the elderly or infirm Central Station Monitoring is especially recommended when used for medical alarm purposes Includes long life lithium battery RADIO REED SWITCH Ness Radio Reed Switch for wireless door and window protection Includes long life lithium battery Top RR2 Mini Radio Reed Switch Bottom RR3 Micro Radio Reed Switch RADIO KEYPAD A unique fully portable radio keypad The Ness Radio Keypad provides wu 2 2 totally wireless Arming Disarming of the control panel Also operates Home Mode and provides a Panic alarm The Ness Radio Keypad is suitable for use as a portable keypad or for adding an extra keypad in areas where it is not possible to install wires AUSTRALIA 1 es r R12 Radio PIR M R15 Radio PIR RADIO MOTION DETECTORS Ness R15 Radio PIR and Ness R12 Radio PIR for wireless motion detection Can be used in combination with Ness hardwired detectors
27. wed by E Press 6008 E Three beeps will sound JJJ and the respective AREA icon will turn OFF D 2 OF 65 NESS D24 CONTROL PANEL USER MANUAL EA ADMINISTRATOR CODES TO ARM AREAS USING AN ADMINISTRATOR CODE Using an Administrator Code to Arm selected Areas Press 20 E 6008 E to Arm multiple Areas at once D E D E aw O E Cara 006 E Three beeps will sound ddd and the selected AREA icon s will turn ON 81 OF 2 OF AREAS Leave the Area within the Exit Delay Time At the end of Exit Delay Time 1 beep will sound J SHORTCUT ARMING 5 ALLOWED FOR ADMINISTRATOR CODE ARMING When Shortcut Arming is enabled Two Button Keypad Operation is enabled CODE is not needed Two Button Keypad Operation is disabled CODE E is not needed TO DISARM AREAS USING AN ADMINISTRATOR CODE Using an Administrator Code to Disarm selected Areas Press E CODE E 0r to Disarm multiple Areas at once 1 and or 2 E and or 3 E CODE E Three beeps will sound and the selected AREA icon s will turn OFF or AREA 1 or AREA 2 AREA 3 Or a Shortcut to Disarm all Areas Press CODE E Three beeps will sound RN and all AREA icons will turn OFF or AREA 1 or AREA 2 AREA 3 15 NESS D24 CONTROL PANEL USER MANUAL MONITOR MODE ARMING MONITOR MODE Monitor mode allows you to Arm selected zones while others are ignored Typically us