Home

USER MANUAL

image

Contents

1. 12 months from the date of purchase The additional 12 months is valid when the machine is registered within 6 months of purchase As a Medical Device it is essential your machine is re validated and re calibrated at least once a year to meet the cleaning performance subject to mandatorv compliance to AS2773 2 AS4187 HTM 10 05 and HTM2030 See http www soniclean com au contact us services We undertake to repair or exchange FREE OF CHARGE anv part found to be damaged due to a manufacturing fault This warrantv is not transferable and does not cover damage caused bv misuse neglect failure to observe operating instruction failure to keep the unit clean accident use of incorrect power supply or attempts to repair by unauthorised personnel The ultrasonic bath tank is not covered against chemical and or cavitation ultrasonic erosion Damage to the transducer caused by excess thermal shock or by other mechanical stresses or attempts to switch on the unit without water liquid is also not covered by this warranty The purchaser agrees to undertake the cost and responsibility of packing and dispatch for safe and timely transportation of the unit to the manufacturer via the premises of the distributor or authorised sales agent IMPORTANT Please retain purchase invoice or receipt for verification if required by the manufacturer Purchaser Contact Details Email Purchased from Date of Purchase Model Serial No Notes Personal
2. Software Version Setup Enable or disable audible key press Press Less key to silent operation using b OFF Press More key b On Load factory values The display shows F SEt Press More or Less key to toggle F On The factory values are Ultrasonic power 100 Clean Time 15 0 minutes Degas Time 5 0 minutes Issue date 190913 1 Heater Temperature 50 CC Dutv cvcle disabled Lid disabled Beep enabled User setup Use More or Less kev to toggle U On Lid interlock option Use More to enable lid interlock Use Less to disable lid interlock When lid interlock is enabled and the lid is open When the lid interlock is enabled and the lid is opened the ultrasonics will pause When lid is replaced press Start to continue Power set to enable or disable Duty cycle Default value is 50 of 5 sec period See status key for the Duty cycle set Enable Duty Cycle with More key factory default 50 power Disable Duty cycle with Less key and ultrasonic is set to continuous 100 duty set operation Clear Press Clear to Switch off heater Remove error message without starting up ultrasonics Restore user setting Reset factory setting Press Status key and scroll through to check status on user or factory setting During Setup or Status key presses use Clear to exit routines More Less Set Heater On from 0 C to 60 C First key press displays set temp
3. information submitted to us will be treated with the strictest confidence and in accordance to our privacy policy Issue date 190913 1 CONTACT INFORMATION SONICLEAN PTY LTD ACN 057 730 917 ABN 89 057 730 917 38 Anderson Street Thebarton South Australia AUSTRALIA PO Box 398 Stepney 5069 South Australia Australia Phone 61 8 8234 8398 Fax 61 8 8234 8391 Web www soniclean com au Email sales soniclean com au Your local Distributor contact information SO EASY SO FAST SO CLEAN SONICLEAN Issue date 190913 1
4. SO EASY SO FAST SO CLEAN FAN SONICLEAN O Adaptive Pulse Swent Power USER MANUAL FOR SONICLEAN DIGITAL BENCHTOP ULTRASONIC CLEANERS MODELS 80TD 120TD 160TD HD 250TD HD 500TD HD 800TD HD 1000TD HD 2000TD HD 3000TD HD amp 3800TD HD For further information visit Soniclean Helpdesk http helpdesk soniclean com au Issue date 190913 1 CONTENTS PRECAUTIONS SAFETV INSTRUCTIONS CONTROL PANEL OPERATING YOUR UNIT PREPARATION BASIC SETTINGS DEGAS FOR HEATER MODEL ULTRASONIC PERFORMANCE ADVANCED SETTINGS REFERENCE TABLE TROUBLE SHOOTING CUSTOMER WARRANTY RECORDS MANUFACTURER SUPPLIER WARRANTY RECORDS CONTACT INFORMATION Issue date 190913 1 PRECAUTION SAFETV INSTRUCTIONS PRECAUTIONS Membrane kevpad The touch sensitive kevpad is waterproof with easv wipe down surface Do not operate kevs with sharp objects If water enters under the fascia send the unit to an authorized Soniclean service center for repair Aerosols Do not switch on ultrasonic without the lid to prevent possible dangerous aerosols from the liquid Keep lid and tank edge drv to reduce aerosol Models with interlock lid must be enabled to prevent unit operating without the lid Ultrasound pressure It is recommended to cover the tank during the operation Do not position ears directly over bath Noise from ultrasonic is rated around or below 85dBA At high power the unit can generate very high fr
5. e changes add hot water to a cold tank or cold water to a hot tank use external or immersion heater or pour excessively hot or cold liquid into the tank This will damage your unit Note the temperature will rise slightly when the ultrasonics is switched on operate without adequate liquid allow cleaning solutions to become excessively contaminated use dangerous liquids Soniclean Pty Ltd does not accept responsibility for accidents arising from the use of toxic flammable corrosive liquids Issue date 190913 1 operate in normal room temperatures around 25C use adequately and correctly earthed mains electricitv supply with correct voltage to your ultrasonic cleaner Check with qualified electrician if in doubt fill at least 2 3 full or full on heated models use a basket trav rack to prevent contact between objects and the tank ensure all splash marks and spillages are cleaned off the unit immediatelv OPERATING YOUR UNIT CONTROL PANEL SO EASY SO FAST SO CLEAN SO NICLEA N e 555 dre l Clear Setup Status as wr y A Se iv Heater Power Start OnOff Level Less More Degas Stop PREPARATION 1 Set the unit on level surface to enable liquid to drain out completely 2 Check for the correct voltage See back label on the unit Plug in your ultrasonic cleaner and switch on at the power point 3 Close the drain valve and fill the tank with cold room temperature or tepid water to 2 3 full or full for hea
6. equency pitch which is harmful to sensitive ears Power supply Check that your mains supply is adequately earthed before plugging in to ensure that the voltage is correctly rated Do not attempt to open the unit powered to mains which can cause an electric shock Opening the unit will void the Warranty unless authorised by Soniclean Unit is sealed to International Protection Standard 1P66 67 Insulation tests Insulation resistance tests can not be performed at 500Vdc due to an internal 275Vdc surge arrestor Tests should be limited to 250Vdc Please refer to AS NZS 3551 2004 Technical management programs for medical devices section 5 3 4 Insulation resistance test specifications SAFETY INSTRUCTIONS The ultrasonic vibrations of these cleaners are transferred to the water by means of a ceramic transducer which is bonded to the underside of the tank These transducers are brittle and can easily be damaged through incorrect use However with proper care they can give many years of reliable service Following these directions will prolong the life of your unit and increase the effectiveness of the cleaner DO NOT subject unit to mechanical or thermal shocks immerse your unit drop or place heavy or sharp objects directly in tank place objects into tank while ultrasonic cleaning is in progress overload tank as this can damage parts and is less efficient in cleaning subject tank to thermal shock ie sudden temperatur
7. erature Set temperature with More and Less key Set Cleaning from 1 to 99 minutes Press Start to clean with countdown timer More or Less key changes timer to a new value The next Start will continue with the new set time Version S d 08 1 60 Set Degas 1 99 minutes More or Less key changes degas time The next Degas will continue with the new set time Version S d 08 1 60 Power Level Setup More or Less key toggles Enable or OFF states as displayed Preset Degas and Cleaning time using More or Less key Status More or Less key is used in most functions Also see Status key description Clear Not applicable Degas Not applicable Single press of More and Less key will increase or decrease number by 1 in most operations In the clean time holding longer duration changes XX ct values by 10 Issue date 190913 1 TROUBLE SHOOTING GUIDE Foil test Poor Check power level set should be set to High Sla Does the unit have recommended amount of detergent Is the detergent approved by SONICLEAN Has the unit degassed properly Whilst in the degas mode look for suspended bubbles in water There should not be any Is the water too hot If so remove some not all and replace with cold water Replenish the detergent to bring to the correct concentration Is the aluminum foil too thick should be 0 025mm thickness Is the water too dirty If so replace with fr
8. esh water Note water quality can vary from day to day and from place to place Degas again 7 Remove trays and instruments part during foil test Note Good foil test Very fine indentations and holes at shorter test duration Longer foil test causes perforations If the unit stops 1 Allow unit to cool down unplugging switch off at wall while 2 If bath water is hot empty out bath operating 3 Wait for at least half an hour before switching on the unit Cause could be again thermal cutout 4 If unit still does not work contact your supplier or SONICLEAN NOISE If unit makes a screeching noise switch Off and try letting screeching unit sit for a few minutes to degas again Error messages Water over temperature when unit is above max 70 C and the unit will cut out allow unit to cool down and press Start to continue Ultrasonic power overload or over current or electronics over temperature allow unit to cool down and press Start to continue When Lid is enabled and lid is open When the lid interlock is enabled and the lid is opened the ultrasonics will pause When lid is replaced press Start to continue Moisture detected inside the unit from by leakage or condensation the unit will cut out This error message may be reset with any key press Issue date 190913 1 CUSTOMER WARRANTV RECORDS WARRANTV Customer Records For goods purchased in Australia af
9. s Heater Off to switch off the heater 16 The LED displav blinks when the liquid reaches the set temperature 17 Ensure that minimum liquid level is maintained to prevent heater shut down 18 If the heater shuts down top up liquid press Heater On again ULTRASONIC PERFORMANCE 19 To ensure vour unit is working effectivelv a dailv aluminum foil test is recommended 20 Soniclean recommends 0 025mm thick aluminum foil Thicker foil will not work For consistent results use SONIC 1 ARTG No 141350 detergent dilution 0 5 3 0 and fluid temperatures from 22 C 40 C 21 Sonic 1 detergent has been specially formulated by Soniclean to give the best results for Soniclean machines Be aware that certain chemicals or excessive amounts of certain chemicals affect the performance or damage unit Check with your supplier if in doubt 22 Soniclean now provides an Ultrasonic Performance Meter UPM Model Sonic 200 250 which validates or takes the place of the foil test Refer to Australian Standard AS2773 2 23 Check Soniclean Web Site www soniclean com au for further information and updates for UPM and Foil Test Issue date 190913 1 Soniclean s Ultrasonic Performance Meter Soniclean s detergents ADVANCED SETTINGS 24 Check to ensure the features and functionalities correspond to software version number Press Status kev and scroll through to displav eg software version 25 Press Status key repeatedly to scroll through various
10. settings on the unit The Status kev displavs information such as tank temperature clean time degas time power level and software version 26 The Setup kevs have other functionalities At present these enable disable buzzer and lids 27 Ultrasonics over prolonged operation will increase above preset temperature Power dutv cvcle helps maintain preset temperature over prolonged ultrasonic operation Use Setup to scroll to power dutv cvcle P dc Factorv default power dutv cvcle is off Press More key to turn on showing dc On or press Less key to d OFF to restore to factory default 28 To save optimized settings when the unit is powered press Setup and scroll through display showing U SEt Press More or Less keys to U On confirm saved user setting 29 User setting can be changed by repeating steps 4 6 and automatically saved so long as the unit is powered on 30 To return to factory setting simply press Setup and scroll through display showing F SEt Press More or Less keys to F On to confirm factory setting REFERENCE TABLE 31 The table below is a quick reference to display key functions and error messages We encourage users to familiarize with the advanced functionalities of keys in blue text left of display Start Stop Power On for ultrasonic cleaning End of cleaning cycle Cleaning time in MM SS where MM in minutes and SS in seconds The cleaning time is preceded by degassing cycle Issue da
11. te 190913 1 Water temperature updated everv 5 sec XX 100 Power levels Degas Degas displavs everv 5 sec Cleaning time The displav isin MM SS where MM in minutes and SS in seconds Degas cycle is H 3 M 1 L 1 OFE1 SEC Power Level Press repeatedly to scroll through and select Power levels when unit is in standby or operating Heater On Off Heater On Key valid when heater is enabled The LED will blink when the set temperature is reached With out ultrasonics the H On display will flash after one minute to indicate that the heater is on Heater OFF Key valid when Heater is disabled Use More or Less to set temperature Max 60 C XX C LED lights up when heater is active Status XX C Water temperature updated every 5 seconds XX C Heater temperature set Dot before C indicates heater set temperature MM SS Cleaning time The display format is MM SS where MM is minutes and SS is seconds Total cleaning time includes degassing time 100 P 80 P 60 P Power level set Display 100 P 80 P 60 P XX ct Cleaning set time where XX is from 1 to 99 minutes XX dG Degas time set where XX is from 1 to 99 minutes XX dc Duty cycle factory default set is 50 showing 50 dc Use More or Less key to change the values When activated in Setup this functionality will be activated when the bath temperature is close to the set temperature
12. ter 1 Januarv 2012 Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure The benefits under our warranty described below are in addition to other rights and remedies under a law in relation to the goods Our Soniclean Ultrasonic Cleaner is guaranteed for 12 12 months from the date of purchase The additional 12 months is valid when the machine is registered online within 30 days of purchase date As a Medical Device it is essential your machine is validated and calibrated at least once a year to meet the cleaning performance subject to mandatorv compliance to AS2773 2 AS4187 HTM 01 05 and HTM2030 See http www soniclean com au contact us services We undertake to repair or exchange FREE OF CHARGE anv part found to be damaged due to a manufacturing fault This warrantv is not transferable and does not cover damage caused bv misuse neglect failure to observe operating instruction failure to keep the unit clean accident use of incorrect power supply or attempts to repair by unauthorised personnel The ultrasonic bath tank is not covered against chemical and or cavitation ultrasonic erosion Damage to the
13. ter models BASIC SETTINGS 4 Simply press Start or Degas keys to commence these cycles To cancel cycles press Stop key 5 To change the timing cycle press More or Less keys to increase or decrease cycle time Factory default is 15 minutes for clean and 5 minutes for degas 6 Once cycle times are optimized simply press Start or Degas and display shows the selected optimized time cycles during countdown DEGAS 7 Adda specified amount of recommended detergent to the ultrasonic tank For the best results first start the machine and then sprinkle the detergent along the insides of the tank 8 Press Degas to expel air bubbles from the water This takes 1 5 minutes depending on water quality Degassing is complete when cavitation surface ripples become evident 9 Adjust time using More or Less keys if necessary or press Start Issue date 190913 1 10 Adjust down Power Level if required Default is 10090 maximum power These optimized basic settings will be retained so long as the unit is powered on 11 Leave unit to complete the operation or press Stop to cancel 12 Operate with the lid on where possible 13 After cleaning rinse parts using clean running water FOR HEATER MODELS 14 Follow steps l 6 before switching on heater 15 Press Heater On to change heater temperature using More or Less kevs to increase or decrease temperatures Factorv default is 50 C Place lid on the unit to prevent heat loss and evaporation Pres
14. transducer caused bv excess thermal shock or bv other mechanical stresses or attempts to switch on the unit without water liquid is also not covered by this warranty The purchaser agrees to undertake the cost and responsibility of packing and dispatch for safe and timely transportation of the unit to the manufacturer via the premises of the distributor or authorised sales agent IMPORTANT Please retain purchase invoice or receipt for verification if required by the manufacturer Purchaser Contact Details Email Purchased from Date of Purchase Model Serial No Notes Personal information submitted to us will be treated with the strictest confidence and in accordance to our privacy policy Issue date 190913 1 MANUFACTURER WARRANTV RECORDS WARRANTV Manufacturer Records Return to Manufacturer For goods purchased in Australia after 1 Januarv 2012 Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure The benefits under our warranty described below are in addition to other rights and remedies under a law in relation to the goods Our Soniclean Ultrasonic Cleaner is guaranteed for 12