1. Q agdia    Leading the way to healthy crops     USER GUIDE  Agdia ImmunoStrip   Test    KIT INFORMATION    Intended Use    The ImmunoStrip test is a rapid means of screening crops for the presence  of pathogens  ImmunoStrip tests require no equipment or expertise to run   Results are obtained in as little as a few minutes making them perfect for use    Agdia  Inc    30380 County Road 6   Elkhart  IN 46514   Phone  574 264 2615 or toll free 800 622 4342  Fax  574 206 9360   Web  www agdia com   Email  info agdia com    ImmunoStrip Kit  ISK  Includes     ImmunoStrips   e SEB1 sample extraction bags  e User guide    in the field or greenhouse  The ImmunoStrip must be used with SEB1 sample    extraction buffer for leaf  Do not use any other sample extract buffer     Storage of Kit    ImmunoStrips should be stored refrigerated  4  C  between uses and tightly    sealed in the desiccated container at all times     Kit contents should be warmed to room temperature prior to use     PERFORMING THE ASSAY   Special Attention Required     Prepare Sample    Collect a sample section that is approximately   1 inch square in size  It is recommended that  samples be taken from areas of the plant that  exhibit symptoms of disease     Note  It is recommended that you use a clean  cutting tool for each sample  If you must reuse  the cutting tool  first wipe off the cutting edge  and disinfect in a 10  bleach solution before  cutting into a new sample     Cut open the sample extraction bag along t
2. f pink   purple  this indicates a  positive   result     Positive  Negative    If no lines are present  the test is invalid   see troubleshooting         SAFETY    ImmunoStrips and sample extraction buffer are non hazardous     TROUBLESHOOTING    Control line did not develop     Test runs very slow or not at all     Test has a green or pigmented test line     Test and   or control line is weak     m175 1    This situation is generally caused by over submergence of the test strip in the sample extract   Results in this situation should be considered invalid and the test should be repeated     This can be caused by using too much tissue for extraction  Repeat the test using less tissue or by  diluting your sample extract 1 10 with SEB1     If the above is not the case  make sure the test components were warmed to room temperature  before use and are within their expiration date     This can be caused by using too much tissue for extraction  Repeat the test using less tissue or by  diluting your sample extract 1 10 with SEB1       In rare cases  the tissue type may cause a pigmented line  Green lines should not be considered  a positive result  Red  orange  or purple fruits may cause what appears to be a positive test line  It  is recommended that you contact Agdia before testing these types of samples     Make sure the test is within its expiration date     If kit contents were left open too long  the strips could have absorbed moisture  which can affect  test results  Be sure 
3. he  top of the label  Be careful not to spill the buffer      SEB1 Buffer is required to perform this assay  with leaf tissue     Insert the sample between the mesh linings near  the bottom of the sample extraction bag     Extract the sample by rubbing it gently between  the mesh linings with a blunt object such as a  pen or permanent marker        Depending on the sample type  the color of the  solution will turn a light brown or green color  once the sample is adequately extracted     m175 1    ImmunoStrips  STX  purchased separately do not include buffer  filled mesh bags     What   s required to perform the assay    e Scissors  knife or razor blade   e SEB1 sample extraction buffer   e Sample extraction device  Agdia sample extraction bags are  recommended    e Letter holder or other device to hold sample extraction  bags    Perform Assay    Insert the ImmunoStrip into the channel portion  no  mesh  of the buffer filled bag      Be sure to insert the    sample    end of the strip no  more than      or to the white line on the ImmunoStrip  label        Allow the ImmunoStrip test to remain in the sample  extract for 30 minutes  Positive results may be visible  in as little as 5 minutes  Lower titer samples may take  up to 30 minutes           T  Interpret Results    Remove test strip from extract and  interpret results  see illustration     If only the control line  C  is visible  this  indicates a negative result     If the test line  T  is also present at any  intensity o
4. to always keep the ImmunoStrip vial tightly sealed between uses     The test line may be weak due to low pathogen titer in the sample        
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
説明書 - 任天堂  一般産業・造船・建築設備用  MessageManager Firefox User Manual  取扱説明書 - 近畿電機    August - Silvaco  Severin HT6005 hair dryer  Lab User Manual - UW NNIN Washington Nanofabrication Facility  Star Micronics TSP650 TSP651L      Copyright © All rights reserved. 
   Failed to retrieve file