Video + Power + Data (VPD) TRANSMITTER Integration - D-max
Contents
1. VIDEO TRANSMITTER amp RECEIVER with POWER CONTROL DATA Video Power Data VPD TRANSMITTER DMS 200CP DCT 107 DCT 407 Integration User s Guide D MAX Release Version 1 0 Coaxial cable connection When you want to extend or terminate coaxial cable connect the cable as below BNC M BNC JJ extension connector BNC M mm E Coaxial cable s terminate part Connect to receiver has to connect BNC F or F connector as above Please do not connect an RCA cable with Coaxial cable Connecting a 75Q BNC F connector at the Good terminal of coaxial cable Bid Twist coaxial cable or connect with a z cable by tapping 1 Introduction 1 1 Concept 1CH 4CH Power Data Video Transmitters were organized with PTZ Camera DMS 200CP and DCT 107 DCT 407 Power Data Video Transmitter has RS 485 interface A large output of Power and long distance transmission functions So it s possible to save the construction period and cost together 1 2 Feature Power Data Video on One cable transfer RS 485 Interface DCT 107 DCT 407 to PTZ CAM One Way Excellent Noise Reduction for High quality picture image Productivity of construction would be improved due to One cable wiring Safety Power transmission by Automatic Wire Checking function The Surge Protection function was included in the Transmitter for safety The Alarm In amp Out f
2. 7 Communication Status Marking LED GREEN OFF state gt Maintain Green Light Data transfer Alarm Input gt Flickering Green Light YELLOW LED Power On gt Light On Data Input gt Flickering Light 8 4P Terminal Block RS 485 Interface connect with Controller Please check RS 485 or RS 485 and then connect it with device ES Release Version 1 0 2 2 DCT 407 Front view 1 AC Main Power Switcher Before Installation Please Turn Off the power and then start to install 2 Data Indication LED GREEN LED OFF state gt Maintain Green Light Data Transfer Alarm Input gt Flickering Green Light RED LED OFF state gt Maintain Red Light Data Input gt Flickering Red Light 3 DIP Switcher Set up the BAUDRATE Switcher NO 9600 bps Default ON OFF OFF Set up the 4800 bps OFF ON OFF BAUDRATE 2400 bps OFF OFF ON Auto Test Mode OFF OFF OFF Auto Test Mode as it used for Quality Test on shipping is not recommended for common use Factory Default Value is 9600bps 4 Link Indication LED RED LED OFF state gt Maintain Red Light Normal LINK state gt Flickering Red Light Release Version 1 0 Rear view ALARM gt Do Not Use Not Circuit 1 BNC CABLE Co
3. as it used for Quality Test on shipping is not recommended for common use DIP Switcher 4 is a switch to select terminating resistance gt OFF To release terminating resistance Factory Default Value ON To set terminating resistance Factory Default Value is 9600bps How to set RS 485 terminating resistance When you use RS 485 data line of DVR or Controller with other equipments other than DCT 107 set as OFF On using only DCT 107 set as ON 2315 Release Version 1 0 If you connect many TX DCT 107 to one PTZ Controller connect as below picture Set TX 4 Switch looped through as OFF and set TX 4 Switch connected to final termination as ON TERMINATION OFF TERMINATION ON TERMINATION OFF RS 485 B RS 485 A PTZ Controller Xx On using many DCT 107 equipments how to connect and set terminating resistance 3 Link Status Marking LED RED LED On accepting power switch will be flickering on and off As normally linked the light will be on 4 2P T Block DC 48V IN Use the provided Power Supply 5 4P Terminal Block ALARM OUT Receiver CAMERA sends an Alarm signal to Transmitter DCT 107 Then Transmitter s Relay controls the Output Device of Contact Point Normal Open gt When an Alarm signal input the Output Device of Contact Point would be closed 6 BNC CABLE VIDEO OUT Connected to DVR or Monitor
4. C F BNC M Harness 60Cm Connect DATA RS 485 One Way T Block Port Alarm Output 1CH T Block Photo MOS Relay Capacity 60V 0 5A Normal Open type Operating Temp amp Humidity 10C 50 0 80 Material Weight Steel 3 5Kg Dimension 430 W X 44 H X 350 D mm Release Version 1 0 4 Configuration System Diagram Relay Out 5 Coaxial Vl Video Data Power Video Out s DC 48V 1 35A AC 100 240V 50 60Hz Junction 1 L n Camera 2 GN w Camera 3 GN j w Camera 4 Ni ce v Video Out X4 Control Keyboard Release Version 1 0 DCT 107 DCT 407 Front http www d max co kr
5. nnect to DVR or Monitor 2 BNC F Connect Coaxial Cable with CCTV Camera 3 4P Terminal Block ALARM OUT Receiver CAMERA sends an Alarm signal to Transmitter 407 Then Transmitter s Relay controls the Output Device of Contact Point Normal Open When an Alarm signal input the Output Device of Contact Point would be closed 3 4P Terminal Block RS 485 Interface RS 485 Interface Connected with the Controller Please Check RS 485 or RS 485 At First After That Connect it with Device 5 ACINLET AC Power Code Input 3 Specification Release Version 1 0 MODEL DCT 107 1CH Transmitter Video Output Signal CVBS 1 0Vp p 759 Power Consumption Input DC 48V 1 35 Working verify checking Tx Green Rx Yellow Transmission distance Automatic controlled RF In amp Output BNC F BNC M Harness 60Cm Connect DATA RS 485 One Way T Block Port Alarm Output 1CH T Block Photo MOS Relay Capacity 60V 0 5A Normal Open type Operating Temp amp Humidity 10C 50 C 0 80 Material Weight Aluminium 240g Dimension MODEL Video Output Signal 93 W x 92 H x 35 D mm DCT 407 4CH Transmitter CVBS 1 0Vp p 759 Power Consumption Input AC 100 240V 50 60Hz Working verify checking Tx Green Rx Red Transmission distance Automatic controlled RF In amp Output BN
6. unction supports Emergency Alarm Siren and Warning Light Release Version 1 0 1 3 Video signal Data signal and power transmission distance as coaxial cable type Inner conductor Operation distance m is Q jen Video DATA Video DATA POWER ECX 3C 2V 18 28 Annealed 0 5 560 340 ECX 5C 2V 8 48 Annealed 0 8 880 750 20 Bare 1 02 990 310 8 32 Annealed 1 2 1 100 750 7C HFBT 7 6 Bare 1 63 1 480 830 3 96 Annealed 1 8 1 480 1 390 RG 59 U 9 1 Annealed 0 81 790 690 RG 6 U 6 1 Annealed 1 01 990 990 RG 11 U 3 7 Annealed 1 63 1 400 1 400 RG 11A U 6 2 Bare 1 63 1 030 1 030 The operation distance could be changed according to installation condition or cable connection status 1 4 Product Configuration per each Model DCT 107 DCT 407 Release Version 1 0 2 Product Front View and Setting Up 2 1 DCT 107 Product Front View ALARM IN N C Not Circuit Coaxial Cable Link lE i VIDEO OUTPUT 1 BNC F Connect to camera with Coaxial cable 2 DIP Switcher Set up the BAUDRATE Switcher NO 2 3 9600 bps Default ON OFF OFF OFF Set up the 4800 bps OFF ON OFF OFF BAUDRATE 2400 bps OFF OFF ON OFF Auto Test Mode OFF OFF OFF OFF X Auto Test Mode