1. heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose of batteries in a fire as they may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hands Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of batteries Disconnect charging source prior to connecting or disconnecting batteries terminal 2 3 4 5 servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions should be taken Keep unauthorized personnel away from batteries When replacing batteries replace with the same number of the sealed lead acid batteries The socket outlet shall be installed near the equipment and easily accessible With the installation of the UPS it should be prevented that the sum of UPS and the connected load leakage current exceeds 3 5mA This pluggable tyoe A equipment with battery installed by the supplier is operator installable and may be operated by laymen Attention Hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage stil
2. BRAVER UPS Uninterruptible Power System User s Manual Safety CAUTION This UPS utilizes voltages that may be hazardous Do not attempt to disassemble the unit The unit contains no user replaceable parts Only authorized service personnel may perform repairs Internal battery voltage is 12V DC Sealed lead acid 6 cells battery Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock hazard as well as violate local electrical codes In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in location where there Is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space
3. ions occur that are not listed above please call service people immediately Specifications MODEL A Braver UPS CAPACITY 400VA 600VA 800 VA A Range 170 280V AC Frequency 40Hz above 230V AC Voltage Regulation NE Battery Mode RU OD OUTPUT Frequency 50Hz or 60Hz Frequency Regulation 1 Hz Battery Mode Output Waveform Modified Sinewave BATTERY Battery Type 12V 4 5Ah 12V 7Ah 12V 9Ah Recharge Time 8 hours to 90 after complete discharge TRANSFER TIME Typical 4 8ms as ran Backup Mode Orange light flashing Backup Mode Beeping every 10 seconds Beeping every second AUDIBLE ALARM Dimension PHYSICAL mm Dx W x H Saezek Net Weight 6 5kgs Operating 40 C 0 90 relative humidity ENVIRONMENT Environment non condensinc Less than 40dB INTERFACE Graz
4. l may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside of the UPS is necessary System Description Front Panel 1 Power Switch amp LED Indicator 2 LED Indicators AC Mode Green Lighting Battery Mode Yellow Flashing Fault Mode Red Lighting 1 Power switch 2 LCD display an eea e Ga Ek jm SZ O p A E E E gt eu d ed e E A gone ome bet b a J y Back Panel 1 Output receptacles 2 AC Input with AC fuse 3 Modem Phoneline Surge Protection 4 Communication Port Installation and Operation Installing the UPS is as easy as following the steps shown Be aware of the Power Switch must be kept in the ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure 1 Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping If any damage is discovered repack the unit and return it to the place of purchase 2 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive con
5. on the UPS 9 Green Power Function Braver UPS is equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on inverter mode Software Installation WinPower XP WinPower XP is a UPS monitoring software which provides user friendly interface to monitor and control your UPS de UPS monitoring software A E izi x System UPS Logs View Help Voltage Sa BYPASS o Voltage 220 0 Y Frequency Load 008 gt Max Volt On Battery Min hb 00 00 00 AC LINE pa Model i pi Yoltage 41 40 COM Port Standard 36 00 Y Temp Capacity 100 0 Trouble Shooting Possible Cause 1 Battery weak Re Ukerdi battery up to 8 hours battery 3 Power switch is not 3 Press the power switch again pressed Overload of the UPS Verify that the load matches the UPS capability specified in the SPECS 1 Overload of the UPS 1 Remove some non critical load failure backup el ee Se 2 Battery voltage is too low 2 Charge battery 8 hours or more temperature operation environment or eli 2 Cable is not properly 2 Check the RS 232 cable is firmly connected connected to COM1 COM2 of the computer and confirm the setting again 1 Fuse is blown 1 Replace the same type of fuse 2 Power cord is loose 2 Reconnect the power cord properly 3 Battery defect 3 Replace the same type of battery lf any abnormal situat
6. taminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from monitor at least 20cm to avoid interference 3 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours 8 hours 4 Computer Connection Connect one computer related device into each of the power receptacles supplied on the back of the UPS maximum of three devices 5 Modem Phone line Connection Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as shown incoming Internet line 6 Serial Cable Connection To allow for unattended system shutdown for your operating system connect the RS 232 serial cable as per diagram below 7 Turn On Off To turn on the UPS press power switch lightly To turn off the UPS please press power switch again 8 DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn

Download Pdf Manuals

image

Related Search

Related Contents

BCP 4300  Powerware PowerRite XT User Manual  Vac Pump RE3022C - Stuart Equipment  Daqstation DX1000/DX1000N/DX2000 PROFIBUS-DP  Page 1 Page 2 畳壁掛けパネル取り 付け面詳細図 (正面から見たと き  Pro-C - SunshowerOnline  owner`s manual manuel d`utilisateur manual del propietario  Introduzione al server Netra 440  Microlife FR 100 Navigation Manual  Jensen JWM-120 User's Manual  