1. Measuring range exceeded Lower limit of analog digital transducer measuring range was exceeded Check if there are all necessary pan elements Unit weigh is too small Entered unit weigh is too small Unit weight is too small or entered number of pieces is too big If a remedy does not have any effect and the communicate is still displayed contact your dealer or service centre 1 A balance should be kept clean 2 Take care that no dirt gets between the casing and the pan If found any remove a pan lift it up remove the dirt and then replace a pan 3 In case of improper operation caused by a short lasting power supply decay unplug the balance from the mains and then plug it in again after few seconds 4 It is forbidden to make any repairs by unauthorised persons 5 To repair a balance please contact our nearest service centre 36 USER MANUAL Declaration of Conformity We AXIS Sp ka z 0 0 80 125 Gdansk ul Kartuska 375B Confirm with all responsibility that AG and AGZ series balances AG100 AG200 AG300 AG500 AG600 AG1000 AG2000 AG3000 AG4000 AGS AGZ100 AGZ200 AGZ300 AGZ500 and AGZ600 AGZ1000 AGZ2000 AGZ3000 AGZ4000 AGZ8 marked with CE mark comply with the following 1 EN 55022 standard Limits and methods of measurement of radio disturbance characteristics of information technology equipment and IEC 61000 4 3 Electromagnetic compatibility EMC P
2. All repairs and necessary regulations can be made by authorised personnel only e To avoid fire risk use a feeder of an appropriate type supplied with the balance Pay attention that supply voltage is compatible with specified technical data Do not use the balance when its cover is opened e Do not use the balance in explosive conditions Do not use the balance in high humidity If the balance seems not to operate properly unplug it from the mains and do not use until checked by authorised service USER MANUAL 7 Preparations working environment When choosing a location to set up the balance remember the following rules to ensure proper working conditions and user friendly operating setup the balance on an even flat surface leaving neccesary room for easy acces maintain proper working temperature avoid strong air drafts vibrations dust big temperature changes and humidity over 90 avoid locations with extreme heat radiation and electromagnetic or magnetic fields 10 USER MANUAL 6 Preparations the balance 1 Take the balance and supplied accessories a feeder pan elements out of the box 2 Place the balance on a stable ground not affected by mechanical vibrations and airflows 3 Level the balance with rotating rear legs 6 so that the air bubble in water level 7 at the back of the balance is in the middle 4 for
3. AG100 AG500 AG 1000 AG4000 AG8 USER MANUAL AG SERIES Plik ER AG 100 01 08 AGOM71 GB 2 USER MANUAL Contents t S General des ase n E D RE UU BO n 3 tees b a p our R NN E 3 d Balac description resnega A OAA 4 4 OVS GUC IndiCalo So Qus EE ttr DOR odore rt a 6 VUE T IUIUS ONG SRK 7 D nt ttti tutte tac tatu 6 7 Preparations working environment Woman 9 8 Preparations the Dalantce an basa ana 10 eset qu noe eoe NU 11 UN CI Ba 12 den 13 12 User functions na E PS EA e Ba 14 RE 15 12 2 PIECES counting function sooo fet ERR eri OU rl o Ee eO SEND 16 12 3 External calibration calibration options sse 18 12 4 RS 232C interface Salto c ati om EDI Ro URDU Pa tcn ici 21 125 Printout SOHO coa dst ge 22 12 6 Date and time Ella 25 IZ SEED SOUINGS o8 DA ces EM ui 26 12 8 Language setting option e seek ER RERO RD Fr Po bius 27 12 9 Weigh summing OO ewer op Sit BB 28 12 10 Maximal minimal value option Woman 29 12 11 Treshold signalization ODIO p ea Deae 3 30 13 Connecting the balance to computer or Printer 34 14
4. none Outputs mode none LI Buzzer stable OK Exit 100 000 s 10096 USER FUNCTION TRESHOLD SIGNAL Deactivate Zero threshold 5 MIN threshold 12 000 MAX threshold none Outputs mode none ke Buzzer lt stable OK gt Exit Buzzer option enables to select sound signal mode When Stable OK option is set sound signal occurs after weighing result stabilisation within OK range Other possible options sound signal occurs when threshold values MIN and MAX are exceeded no sound signal To start function choose Activate option and press ENTER key After each measurement the balance displays comparison result To leave the function press MENU key choose Treshold signalization function and then choose Deactivate option In balances equipped with THRESHOLD output comparison result may be used to control external optical indicator or other external devices Threshold comparison results appear on Thr J and Thr II output pins as a shortcircuit state Control output working modes are presented on the state charts below 32 USER MANUAL THRESHOLD output state charts increasing load 1 Indicator mode 2 Pulse mode 3 Level mode A Outputs P1 thr I t zero thri treshold P2 thr Il P3 zero thr Il A Outputs 2s thr I P2 thr II P3 zero Outputs P1 thr I P2 thr I
5. 2 3 4 5 6 T 8 9 Polish English German Russian Ukrainian Spanish French Czech Exit Press MENU key to enter the user function menu choose Language settings and press ENTER key Select desired language using and v keys and press ENTER key to accept 28 USER MANUAL 12 9 Weigh summing option This function allows separate weighing of several ingredients in one container with a possibility to control aggregated sum of all weighed components USER FUNCTIONS Autotaring PCS counting Weigh summing USER FUNCTIONS WEIGH SUMMING 1 Activate 2 Reset 3 Exit USER FUNCTIONS WEIGH SUMMING 1 Deactivate 2 Reset 3 Exit Ingredients weight 0 000g Number of ingredients 0 Press Menu key choose Weighs summing and press ENTER to accept Chose Activate option using V and keys and press ENTER The balance is now ready for successive ingredients weighing Before weighing each ingredient press gt T key to zero the indication During series weighing total weight and number of series n are shown at the left of the display For instant return to weighing mode and display total weight of all ingredients press 4 key To return to series summation press the key again To leave the function press Menu key chose Weigh summing function and then chose Deactivate option USER MANUAL 29 12 10 Maximal mi
6. FUNCTIONS Press Menu key to enter the user Autotaring function menu choose Counting with PCS counting the cursor and press ENTER key USER FUNCTIONS PIECES COUNTING 1 Activate 2 Sample quantity 3 Unit weight 4 Exit Chose Pieces quantity option and press ENTER key USER FUNCTIONS PIECES COUNTING 1 Activate 2 Sample quantity IA Using numeric keys enter the quantity ES weight of the sample and press ENTER key Exit The balance calculates unit weight basing on given number of pieces and reference sample weight and then shows number of pieces on the display Reference sample parameters may be used in series of weighing To recall previously used sample parameters start Counting function with Activate option To leave the function press Menu key choose Counting function and then choose Deactivate option Note To switch between weighing mode and pieces counting mode press 4 key USER MANUAL 17 2 Counting with unit weight USER FUNCTIONS Press Menu key to enter the user Autotaring function menu chose Counting and PCS counting press ENTER key USER FUNCTIONS PIECES COUNTING Chose Unit weight option and press 1 Activat ENTER key 2 Sample quantity 3 Unit weight 4 Exit USER FUNCTIONS PIECES COUNTING 1 Activate Enter unit weight value using numeric 2 Sample quantity keys and press ENTER to accept The 3 Unit weight uni
7. Troubleshooting and maintenance ocoooooooocooo Woman 35 IB Te s wise Seo osi mm 36 USER MANUAL 1 General description AG series balances are destined for high accuracy weighing in laboratory practice Balances are equipped with internal calibration system for proper accuracy control during operation The user should also own weight standard of OIML F2 or Fl class for periodical control of the balance weight value stated in Technical Data sheet available for extra fee All balances are metrologically tested calibration or legal verification certificate on demand Legal verification is required for balances used in some applications direct sale pharmaceutical prescriptions medical and pharmaceutical analysis goods packing and others Balances with legal verification are mark with the following protective seal placed on the casing mounting screw at the back of the balance calibration switch protective seal notified body stamps and green metrological marking placed on the balance name plate AGZ series balances are destined for purposes where verification is not required AGZ series balances do not have internal calibration system and also all functions connected with it are removed chapter 11 and 12 3 2 Completeness A standard set consist of 1 Balance 2 Pan elements AGS50 AG600 round pan a pan base and a pan AG1000 AG4000 AG8 rectangular pan gum nuts 4pcs and a pan 3 Fee
8. for direct sale use only numeric key data output print transmission numeric key internal calibration numeric key Menu numeric key special function enter an option leave an option navigation move a cursor up navigation move a cursor down result stabilisation tatal load indicator 0 100946 stand by mode metrologic parameters and accuracy class USER MANUAL 5 Technical data Type AC100 AG200 AG300 AG500 Capacity Max 500g Min load Min 0 02g Reading unit d 0 001g Verification unit e 001 Tare range 500g Accuracy class Working temperature 18 33 C Weighing time 8s Pan dimension 115mm Balance base dim 215 235 x345x90mm Balance weight 5kg Power 230V 50Hz 6VA 12V 300mA Calibration weight 100g 200g 200g 500g OIML F2 F2 F2 F1 Type AG600 AG1000 AG2000 AG3000 AG4000 AG8 Capacity Max 80009 Min load Min 50 Reading unit d Verification unit e Tare range Accuracy class Working temperature Weighing time Pan dimension Balance base dim Balance weight Power Calibration weight OIML 0 01g 0 01g 0 01g 0 01g 0 01g 0 1g 19 8000g II 18 33 C 55 165x165mm 215 235 x345x90mm 5kg 230V 50Hz 6VA 12V 300mA 500g 1000g 2000g 5000g F2 F2 F2 F2 8 USER MANUAL 6 Security rules To avoid electrical shock or damage of the balance or connected peripheral devices it is necessary to follow the security rules below
9. if balance RS232C interface transmission parameters are compliant with connected external device parameters To enter correct parameters values select desired parameter using V and A keys and press ENTER key Set correct parameter value using and gt keys and press ENTER to accept To leave the function press MENU key or use Exit option 22 USER MANUAL 12 5 Print out settings This function enables to select desired information which will be used on print outs numeration of succesive measurements date and time of each measurement custom information optional additional text entered with a computer keyboard USER FUNCTIONS Autotaring Press MENU key to enter the user PCS counting function menu choose Print settings and press ENTER key Print settings USER FUNCTIONS PRINT SETTINGS Select desired parameter using V and keys and press ENTER key to change setting Header Header the entrance to the printout header definition menu the checkbox sign indicates if at least one option in the header definition menu is marked Header definition menu USER FUNCTIONS PRINT SETTINGS Relevant element 15 Blank line marked unmarked if ENTER key is Mode name pressed The marked element will Date amp time appear in a printout header if the Balance type Header element in values definition Serial number
10. menu is marked ID1 ID2 ID3 Signature Exit USER MANUAL 23 An example of a full printout header WEIGHING Date 2000 04 25 Time Scale type AGNZ200 Serial number 123456 string ID2 string ID3 string Lure Signa lt blank line Saas lt mode name 22 32 lt date and time lt balance type lt serial number lt IDI lt ID2 lt ID3 lt signature Values the entrance to printout values definition menu the checkbox sign indicates if at least one option in values definition menu is marked Values definition menu USER FUNCTIONS PRINT SETTINGS Header Blank line ID1 ID2 ID3 Measur Number Tare Net Gross LCD result Exit Relevant element is marked unmarked if ENTER key is pressed The values Tare Net and Gross are always expressed in grams The value LCD result always indicates display state with an active unit An example of a full printout header without header string ID2 string ID3 string Measurement number 1 T 0 0000 g N 66 7425 g B 66 7425 g LCD 333 1125 Ct lt blank line lt IDI lt ID2 ID3 measurement number lt tare net gross lt LCD result 24 USER MANUAL Footer the entrance to the printout footer definition menu the checkbox
11. AGI00 AG600 Gently insert the mandrel of pan support 2 into pan socket through the pan ring 3 Put the decorative pan 1 on AG600 balances have decorative pan joined with pan support 5 for AG1000 AG8 Place supports 2 on mandrels visible in balance cover hole put pan 1 on supports USER MANUAL 11 6 Plug a feeder to the power socket at the back of the balance Moisture in the air may condense on the surface of the balance when transferred to the warmer environment In this case leave the balance for at least 4 hours unplugged from the mains for conditioning to avoid wrong operating or damage of the balance Leave the pan empty and plug the feeder to the mains At the end of self tests the balance displays zero indication and is now ready to work 9 Operation principles 1 To ensure proper weighing accuracy the balance is equipped with internal calibration system The system automatically calibrates the balance every 2 hours and with temperature changes more than 1 C without user ingerence Nevertheless it is advised to check balance accuracy with weight standard or other object with known weight before and after each series of measurements 2 Weighed sample should be placed in the centre of the pan 3 In direct sale use d e make sure that zero indicator is displayed If not press gt 0 lt key and wait until zero indication and zero indicator appears In other balances the key does not operate 4
12. I P3 zero zero treshold A zero thr treshold thr thr Il thr II USER MANUAL 33 THRESHOLD output is a open collector transoptor output with load capacity 100mA 24V Additional transmitters require separate 24V feeder transmitter input must be protected with diodes e g 1N4148 AXIS offers MS3K P electronic board consisting of RM96P transmitters with DC24V input voltage and AC250V 8A output sold separately PROGI output Single transmitter connection Transmitter Balance P1 thr 1 P2 thr 2 P3 zero thr groun shield 34 USER MANUAL 13 Connecting the balance to computer or printer The balance may send data to a computer or a printer via RS232C interface RS232C When cooperating with a computer the balance sends weighing result after initialising signal from a computer or after pressing 7 key When cooperating with the balance a computer should be equipped with a program that enables receiving and Case processing data from the balance RxD receiver TxD transmitter GND AXIS offers computer programs to cooperate with balances Demo versions and program descriptions are available on the website www axis pl RS 232C Test free serial port testing program ProCell residual program for cooperation with Microsoft EXCEL and other Microsoft Windows applications demo version Detailed information for programmers The
13. The balance is equipped with a tare equal to its range To tare the balance press T lt key Storing a tare value does not extend measuring range but only subtracts it from a load placed on a pan To make weight control easier and to avoid range overdrawing the balance is equipped with a load indicator graduated in percentages 5 Weighing result should be read when the indicator 2 lights which signalises stabilisation of a result 6 When the balance is not used but it is necessary to be ready to work immediately it can be switched off by pressing I O key The balance reading system is then switched off to standby mode signalled by the indicator OFF To switch the balance on press I O key The balance is immediately ready to operate maximum accuracy after self tests 12 USER MANUAL 7 The mechanism of the balance is a precise device sensitive to mechanical strokes and shocks Before transportation take off the pan move it slightly and lift it up Do not overload the balance more then 2096 of maximum load Max and the pan base and preserve from any damages Do not press a pan with a hand 8 The balance should not be used to weigh ferromagnetic materials due to accuracy decrease 9 When the balance is moved to another localisation remember to level the balance and proceed with internal calibration 10 Start up INICJALIZATION program version V Processor V EEPROM AUTOMATIC CALIBRATION In
14. art 4 3 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test harmonised with the Council Directive 89 336 EEC Additionally AG series balances with following marking on the name plate a sticker with two digit number of the year in which C the mark was affixed and the number of the Notified Body a green metrology sticker with M mark XX 1443 a protective seal affixed by the Notified Body comply with requirements stipulated on the Type Approval Certificate TCM 128 06 4428 and for verification to comply with 2 En 45501 Metrological aspects of non automatic weighing instruments harmonised with the Council Directive 90 384 EEC amended with 93 68 EEC Additional information Conformity evaluation for the Council Directive 89 336 EEC were carried out by Laboratorium Badawcze Oddzia u Instytutu Elektrotechniki w Gda sku Type Approval Certificate no TCM 128 06 4428 was issued by esky Metrologicky Institut Brno Notified Body no 1383 Gda sk 15 01 2007 Per pro Director of AXIS Ltd Production Manager Jan Ko czak ignature
15. balance sends data with a following method Computer Balance initiation signal S I CR LF 53h 49h 0Dh 04 1 Balance Computer weighing result in the following format 16Bytes LONG protocol 8bits Istop no parity 4800bps Bytes description 1 mark or space 2 space 3 4 digit or space 5 9 digit decimal point or space 10 digit 1l space 12 k l c p or space 13 g b t cor 14 space 15 CR 16 LF USER MANUAL 35 14 Troubleshooting and maintenance Display indication Possible cause Remedy Test Auto tests are being performed electronic unit damage wait for 1 minute The balance is during zeroing mechanical damage wait for 1 minute check if the balance is placed on stable ground not affected by vibrations Internal calibration To small zero load or overloading Check if there are all necessary load error of balance mechanism pan elements or if the balance is mechanical damage not loaded Tare range Tare key pressed during zero Balance indications must be exceeded indication different than zero Zeroing range Permissible zeroing range was Remove the load from the pan exceeded exceeded Weighing range Permissible weighing range Reduce the load exceeded Max 9e was exceeded Measuring range exceeded Upper limit of analog digital transducer measuring range was exceeded Remove the load from the pan
16. correct value Choose External calibration option and press ENTER to accept Wait until taring process is finished and load the pan with the calibration weight of correct value Take off the calibration weight Wait until external calibration is finished After external calibration the balance switches to the weighing mode USER MANUAL 21 12 4 RS 232C interface setting To enable cooperation with a printer or a computer transmission parameters must be equal in both devices This function enables the following transmission parameters send and receive speed 1 200 115 200bps number of bits 7 or 8 Bytes parity control none even odd protocole type default protocole LONG transmission mode after L gt PRINT key pressing with stable indication directly after L PRINT key pressing without stable indication automatically after stabilisation of each weighing result continuous transmission in 0 1s periods USER FUNCTIONS Autotaring PCS counting RS 232C settings USER FUNCTIONS RS232C SETTINGS 1 Baudrate 4800 2 Bits 8 bit 3 Parity brak 4 Protocol LONG 5 Sending mode buttontstab 6 Exit USER FUNCTIONS RS232C SETTINGS 1 Baudrate 4800 2 Bits 8 bit 3 Parity brak 4 Protocol LONG 5 Sending mode buttontstab 6 Exit Press MENU key to enter the user function menu choose RS232C settings and press ENTER key Check
17. der ZN12V 500mA 4 User manual 5 Guarantee Card 4 USER MANUAL 3 Balance description Front view AG100 AG600 pan 2 pan support 3 pan ring 4 LCD display 5 keys 6 rotating legs 7 water level 8 antiblast shield Note AG600 does not have the pan ring and the antiblast shield Front view AG1000 AG4000 AG8 pan 2 pan supports 4 LCD display 5 keys 6 rotating legs 7 water level USER MANUAL Rear view N Keyboard Feeder or computer 230V 50Hz seo 000 o oou Oe 4 N Adjustment RS232C Switch RxD receiver ON OFF TxD transmitter Feeder 12V 500mA Oo USER MANUAL 4 Keys and indicators 0 100 keys key key key key key key key key key key key key indicator indicator indicator PI Cd an imr Be gt T Vo ENTER 1 F1 5 85 6 50 1G 8 7 9 MENU 04 gt lt gt A linear OFF Max Min d e TD tare subtract package weight from weighed mass switch off standby confirm decimal point numeric functional keys numeric key zeroing balances
18. ee Calibration options For this purpose a printer or a computer with testing program is necessary The report printout example Date Time Calibration report Date of production Serial number Program version Factory external weight external weight value registered during factory calibration Factory internal weight internal weight value registered during factory calibration Current external weight external weight value registered during last calibration Current internal weight internal weight value registered during last external calibration Weight difference difference between internal weight values factory value current value USER MANUAL 19 Calibration options USER FUNCTIONS Autotaring PCS counting Calibration USER FUNCTIONS CALIBRATION 1 External calibration 2 External load 200g 3 Calibration of time 2h 4 Calibration of temp 1 0 C 5 Report printout 6 Exit USER FUNCTIONS CALIBRATION 1 External calibration 2 External load 200g 3 Calibration of time 2h 4 Calibration of temp 1 0 C 5 Report printout 6 Exit USER FUNCTIONS CALIBRATION 1 External calibration 2 External load 200g 3 Calibration of time 2h 4 Calibration of temp 1 0 C 5 Report printout 6 Exit If an access to adjustment switch is not protected with the mark with a thin screwdriver s
19. eration sequence USER FUNCTION Press MENU key choose Treshold Autotaring signalization option and press ENTER PCS counting to accept Treshold signalization USER FUNCTION TRESHOLD SIGNAL Chose Zero threshold option using V Zero threshold brak he and keys and press ENTER MIN threshold none MAX threshold none Outputs mode none Buzzer none Wyj cie Enter Zero threshold value using decimal keys and press ENTER key Activate indications below this value are Zerothreshold 5 Ae regarded as unloaded balance MIN threshold none threshold indicators does not appear MAX threshold none Outputs mode none Buzzer none Exit USER FUNCTION TRESHOLD SIGNAL Enter MIN threshold and MAX USER FUNCTION TRESHOLD SIGNAL threshold values Activate Zero threshold L Outputs mode enables to set MIN threshold THRESHOLD output working mode MAX threshold described further To choose Outputs mode appropriate working mode use mad and keys and press ENTER key to f accept USER MANUAL 31 USER FUNCTION TRESHOLD SIGNAL Activate Zero threshold 5 MIN threshold 12 000 MAX threshold none Outputs mode none u Buzzer lt stable OK gt Exit USER FUNCTION TRESHOLD SIGNAL Activate Zero threshold 5 MIN threshold 12 000 MAX threshold
20. et adjustment switch to ON position balance displays the message Calibration switch ON and makes a sound Press MENU key choose Calibration option and press ENTER Option External weight enables to enter the value of used calibration weight Choose External weight option press ENTER and use and keys to select desired value It is advised to use as great weight value as possible Calibration of time and Calibration of temperature option is related with internal calibration To print a calibration report connect a printer and use Report printout option Calibration report is a proof of correct calibration process and may be useful for balance diagnostics 20 USER MANUAL Calibration sequence USER FUNCTIONS Autotaring PCS counting Calibration USER FUNCTIONS CALIBRATION 1 External calibration 2 External load 200g 3 Calibration of time 2h 4 Calibration of temp 1 0 C 5 Report printout 6 Exit CALIBRATION External calibration taring CALIBRATION External calibration Put the calib weight 200g CALIBRATION External calibration Remove calib weight CALIBRATION External calibration wait Press Menu key choose Calibration option and press ENTER to accept calibration must be enabled Check if External weight value is equal to external weight value used for calibration If not choose External weight option and enter
21. from the function menu use Menu settings option Select function by cursor and press ENTER key Chosen functions should be signified with V mark To quickly go from functions menu to Menu settings press t key USER MANUAL 15 12 1 Autotaring This function automatically keeps zero indication when a pan is empty or zero indication was forced with T key USER FUNCTIONS Autotaring PCS counting USER FUNCTIONS PIECES COUNTING 1 Activate 2 Correction range 2 d sec 3 Exit USER FUNCTIONS PIECES COUNTING 1 Activate 2 Correction range 2 d sec 3 Exit Min e 4 AUT 0 000 10096 Press Menu key to enter the user function menu choose Autotaring and press ENTER key Choose Correction range using V and A keys and press ENTER key Enter maximum zero flow to be automatically corrected choose between 0 5 5 verification unit s per second Choose Activate option and press ENTER Any changes off the zero readout that are equal to a defined fraction of digits per second are automatically tared independently of changing environment conditions temperature humidity etc To leave the function press Menu key choose Autotaring function and then choose Deactivate option 16 USER MANUAL 12 2 Pieces counting function 1 Counting with a reference sample Place a reference sample with known number of pieces on the pan USER
22. nimal value option This function enables to display a maximal or minimal value of series of weighing USER FUNCTIONS Autotaring PCS counting Maximal minimal value USER FUNCTIONS MAXIMAL VALUE 1 Activate 2 Reset 3 Mode 4 Exit MAX wos USER FUNCTIONS MAXIMUM VALUE 1 Deactivate 2 Reset 3 Mode 4 Exit MAX Press Menu key choose Maximal minimal value and press ENTER to accept Choose Activate option using V and A keys and press ENTER The function is now active the balance displays only maximum value from successive series of weighing starting from the function activation or using Reset option To display weigh value of a current sample press t key To return to Maximum value function press the key again To leave the function press MENU key choose Maximal minimal value function and then chose Deactivate option 30 USER MANUAL 12 11 Treshold signalization option This function compares weighing result with two reference values lower and upper threshold The balance signalises comparison result with MIN OK and MAX indicators and sound signal If comparison result is smaller than lower threshold the balance displays MIN between threshold values the balance displays OK bigger than upper threshold the balance displays MAX lower than zero threshold no load none of the indicators appears Op
23. rvice centre USER MANUAL 12 User functions menu All balances beside basic functions like weighing and tare are equipped with additional functions Basic set of special functions is shown below In respect of metrology calibration with external weight is important special function Other functions recipe ingredients summing density calculation etc can be enabled as an option on customer request described in additional brochure when ordered USER FUNCTIONS amp OPT Autotaring PCS counting Unit selection Percent Calibration RS 232C settings Print settings Time amp date settings LCD settings Menu settings Exit USER FUNCTIONS amp OPT ENABLING V Autotaring PCS counting Unit selection Percent Calibration RS 232C settings Print settings Time amp date settings LCD settings Menu settings Exit To enter the user menu press Menu key The cursor dark background is placed at the top To move the cursor use the navigation keys V and A function activated function deactivated To enter chosen function and open the menu of the function press ENTER key To return to the previous window press lt key To leave the user menu and return to weighing mode choose Exit option Easy access to the most useful functions will shorten operation time and make work more comfortable To remove a function
24. sign indicates if at least one option in footer definition menu is marked Footer definition menu USER FUNCTIONS PRINT SETTINGS Blank line Relevant element is Mode name marked unmarked if ENTER key is Date amp time pressed Balance type Serial number Signature Dash line 3 3 blank lines Exit An example of a full printout footer lt blank line CREE PCS COUNTING mode name Date 2000 04 25 Time 23 05 date and time Scale type AGNZ200 lt balance type Serial number 123456 lt serial number string lt IDI ID2 string lt ID2 ID3 string ID3 Signature lt signature 2 2 2 2 2 2 2 2 2 2 2 2 2 2 22 2 2 separating line 3 empty lines ID1 ID2 ID2 strings max 20 characters defined by PS2 keyboard or by a scale numeric keypad which works similarly to mobile keyboard characters coupled with relevant key appear in a display first line after the key is pressed inscribed string is approved with ENTER key USER MANUAL 23 12 6 Date and time setting Use this function to set current date and time used in print outs USER FUNCTIONS Autotaring Press MENU key to enter the user PCS counting function menu choose Zime amp date settings and press ENTER key Time amp date settings USER FUNCTIONS DATE AND TIME Select de
25. sired parameter using V 1 Time 09 11 03 and keys and press ENTER 2 Date 2006 03 31 3 Exit USER FUNCTIONS DATE AND TIME 1 Time 09 11 03 2 Date 2006 03 31 3 Exit Enter correct values using numeric keys and press ENTER to accept 26 USER MANUAL 12 7 LCD settings This function enables to set contrast and back light illumination of the LCD display USER FUNCTIONS Autotaring PCS counting LCD settings USER FUNCTIONS LCD SETTINGS 1 Contrast z 8 2 Backlight ON 3 Exit USER FUNCTIONS LCD SETTINGS 1 Contrast lt lt 12 2 Backlight ON 3 Exit USER FUNCTIONS LCD SETTINGS 1 Contrast J 12 2 Backlight ON 3 Exit USER FUNCTIONS LCD SETTINGS 1 Contrast 12 2 Backlight lt OFF gt 3 Exit Press MENU key to enter the user function menu choose LCD settings and press ENTER key Choose Contrast option using V and A keys and press ENTER to key Select desired Contrast value using lt and gt keys and press ENTER accept Choose Backlight option using and keys and press ENTER key Turn LCD Backlight on or off and press ENTER to accept USER MANUAL 27 12 8 Language setting option This function enables to select a language used for displayed commends and printouts USER FUNCTIONS Autotaring PCS counting Language settings USER FUNCTIONS LANGUAGE SETTING 1
26. t weigh value is stored in balance 4 Exit eee memory until switched off The balance displays pieces amount Note To correct wrong digits when entering unit weight press lt key to delete the last number or CLR to leave the function and proceed from the beginning 18 USER MANUAL 12 3 External calibration calibration options Calibration with external weight standard in verified balances should be performed in case balance indications exceed permissible error To calibrate the balance aservice centre should use calibration weight as stated in Technical Data table or of better accuracy with valid calibration certificate protecting an access to adjustment switch and results in loosing its EC verification To renew EC verification of a balance contact with service or notified body is necessary Calibration of EC verified balance reguires to destroy a mark for EAE In EC verified balances executing a calibration requires to change adjustment switch position which is placed behind the mark sticker of a E Ceres Je I notified body An access to the switch Ew is possible only after the mark is removed which causes loosing EC Mark verification of the scale To renew EC Switch verification of a balance contact with service or notified body is necessary In order to store results of calibration with external weight it is possible to print calibration report s
27. ternal calibration Please wait After switching on the balance performs automatic self test Each test must be accepted and confirmed with V mark After self test the balance proceeds with internal calibration mode as described in chapter 11 When internal calibration 15 finished the balance is in normal weighing mode USER MANUAL 13 11 Internal calibration Internal calibration is performed automatically after each start up also every 2 hours and with temperature changes more than 1 C To calibrate the balance with internal weight simply empty the pan and press V key twice CALIBRATION Internal calibration Please wait Press V key twice CALIBRATION Until calibration process is finished do not perform any operation as any vibrations and shocks may affect the process of calibration and delay the calibration or deteriorate the result Internal calibration Taring please wait CALIBRATION Internal calibration Loading please wait The calibration weight is placed on the pan three times to avoid inaccurate calibration result In case any problems during calibration the error is signalised on the display and calibration process is stopped The result of correct calibration is zero indication In case internal calibration does not ensure proper accuracy of the balance e g results of weighing object of known weight are wrong please contact the nearest se