        INSTALLATION MANUAL Wired Remote Control - Tom-Eko
         Contents
1. INSTALLATION  MANUAL    Wired Remote Control  MWR VHO1        Energv Recoverv Ventilator                     DB98 27509A 2            DEUTSCH PORTUGU  S ITALIANO FRAN  AIS ESPA  OL ENGLISH    Safety Precautions    This Installation manual indicates you to install the ERV wired remote control  which is connected to ventilator  To install other optional accessories  refer to an  appropriate installation manual      N WARNING     N CAUTION      Do not install the unit by yourself  Incorrect installation of  the unit could cause injury due to fire  electric shock and  water leakage or the unit falling  Consult a dealer or  a qualified installer      Install the product with rated power supply      Do not attempt to repair  modify or disassemble the  unit on your own  Make sure that these installations are  carried out by qualified personnel to avoid electric shock  or fire      The electric work must be done by service agent or  similarly qualified person according to national wiring  regulations and use only rated cable  If the capacity of the  electric work is not properly completed  electric shock or  fire may occur      Install the unit in a place where it is strong enough to  hold the product weight  When installed in place where it  is not strong enough to withhold the product weight  the  unit may fall and cause injury      Do not attempt to move or reinstall the unit on your own   There is a risk of electric shock or fire      Read carefully this installation manual befor
2. an speed and   mode   buttons simultaneously for Dort By Pass   EE  3 seconds     ad E  Ol    The communication is initialized and the ERV wired  Filter  Reset    remote control queries every connected ventilators     Fan Speed Mode    Timer    Confirm  Cancel                         Error Code Display    LCD displays the errors of the ERV wired remote control and    ventilator   LP             If Z  Testis indicated  the corresponding error codes           indicated as well       When LCD displays the same error of several ventilators   the ventilator with the lower address is displayed first             Error Code Display  Continued         Error Display of ERV wired remote control    Explanation Remarks       Communication error between ERV wired remote  control and ventilator  After the communication is cut  off for continuous 3 minutes        Communication error between MASTER ERV wired  remote control and SLAVE ERV wired remote control   After the communication is cut off for continuous 3  minutes        Communication Packet error       Tracking error between ERV wired remote control and  ventilator over 10 times       Cross installation error of COM1 COM2 of ERV wired  remote control       Communication error when both remote controls are When using  set as MASTER 2 remote control       No ventilators installed   No ventilators found after tracking        Not yet installed the external device   The external device is not yet detected after setting up  the option for ex
3. e installation  and check whether the unit is installed correctly after  installation      Consult you dealer when you need to dispose of the unit       Do not install the product in a place where it is exposed  to inflammable gas leakage      Do not spill any kind of liquid into the unit  It may result in  electric shock or fire      Install the unit where there is 0  C to 39  C without being  exposed to direct sunlight      Do not press the unit with a pointed thing      Do not install the product in the place where exposed to  sulfurous acid or steam because it may damage the parts  or cause malfunction      Install electrical wires not to get tension  There is a risk of  being torn which cause fire      Do not install the unit in a place there is exposed to acid  or alkaline liquid or special chemical spray      Do not connect the power plug to electrical wires  It may  result in fire      Make sure that the unit does not affect to other devices in  special environment such as hospital     Contents         ACCESSORIES   II tuti pte Rated eta 4       INSTALLING THE           4  m Installation                 m Setting Up PCB Option Switches     m Installation Examples            INITIALIZING THE COMMUNICATION                 s 9      ERROR CODE DISPLAY                  tns 9    at  4   l      z   iw       Accessories    The following accessories are supplied with the ERV wired remote control       The number of each accessory is indicated in parentheses     M4X16 tapped Us
4. er s manual 1  Installation manual 1   screw 2        The ERV wired remote control must be installed by  qualified installers    Before installing the ERV wired remote control   make sure the main power is off        All cables must be installed according to the national  wiring regulations and must be installed inside the wall  to avoid user contact     Installing the Unit  BI Installation  Connect the power cables and communication cables of the  ERV wired remote control to the terminal of ventilator PCB       1 Open the ERV wired remote control by using the groove on its top     2 Secure the rear cover of the ERV wired remote control to the  wall with 2 screws              3 Connect the V1  V2 terminal of the ERV wired remote control  to the V1  V2 terminal of the ventilator                         g  remote       control 4 Connectthe F3  F4 terminal of the ERV wired remote control    to the F3  F4 terminal of the ventilator        ERV Wired    Electrical wires   Not supplied       Reassemble the ERV wired remote control                             The electrical wires and the power cable of ERV wired remote  control should be installed separately  The ERV wired remote     control may malfunction due to electric trouble                             Installing the Unit  Continued     BI Setting Up PCB Option Switches        Setup the DIP switches of the ERV wired remote control according to the user environment     DIP switch    OFF    ON    at  53   l      22   ra        Re
5. marks       SW1    Auto operation mode  not used    Auto operation mode  used    Use only when the ventilator has  auto operation function       Air purifying mode  not used    External control  mode not used    Air purifying mode  used    External control  mode used    Use only when the ventilator has  air purifying function    Use only when the ventilator is  connected to system air conditioner          Sleep mode not used    Default setting      The SW908 should be set as    0    under all conditions     SW SW2 SU SW4                         ON E  0258 EO   1234 bes   DS01 SW908       Sleep mode used          Classified by domestic commercial  use      Installing the Unit  Continued     B Installation Examples  Individual control      Controlling 1 ventilator individually with 1 ERV wired remote control        ERV wired remote control PCB    SWA SW2 SW3 SW       ON    Master Ventilator         5    234              COMI COMI               jl Main  1 1 Main  2 i Main  3  Ventilator BMC Ventilator RES Ventilator BMC  COM2                   Set as 0  2  Setas 0  Setas 0                                                         ERV wired remote ERV wired remote ERV wired remote  control control control       The ERV wired remote control controls the ventilators which    are connected to the COM2 communication cable oniv     JE  4                ra        Group control     Controlling more than 2 ventilators with 1 ERV wired remote control     Example   When controlling 3 ventila
6. ternal device and tracking     When using  external device                  JE  4  a      z    ra            Error Display of ERV wired remote control when ventilator is detected    Explanation    Remarks       Communication error for 3 minutes after detecting  COMI       Indoor temperature sensor error  Short Open        CO  sensor error  Short Open     Detected only by  the ventilator which  has CO  sensor       EEPROM error       Tracking error or MASTER ventilator  After 5 times of  tracking  SLAVE ventilators can not be detected         System failure due to communication error after tracking       Outdoor temperature sensor error  Short Open        Supply Air fan motor sensor error       Exhaust Air fan motor sensor error       Communication error between ERV wired remote  control and ventilator  After the communication is cut  off for continuous 3 minutes        Communication error by installing COM1 dual MASTER          Detected only by  CCA the ventilator which  HA Temperature sensor error  Open Short  has temperature  sensor  CICLI Damper error  When there is no switch input for 100 _  LID seconds while monitoring the damper              ik Refer to the ventilator installation manual for the errors    of ventilator                ELECTRONICS    
7. tors with 1 ERV wired remote control           ERV wired remote control PCB  SW SW2 SW3 SW    EN             12    34    Master Ventilator                        Main  1  RMC 1          Ventilator Main  3    Ventilator RMC 2 RMC 3    Ventilator    COM2                                 Setas 0                 ERV wired remote  contro       The ERV wired remote control controls the ventilators which       are connected to the COM2 communication cable only     Installing the Unit  Continued        Using 2 remote controls              2 remote    means that 2 ERV wired remote controls are used to control 1 ventilator     Set the DIP switch of the ventilator PCB as seen in the picture     Master Ventilator          1 Main  1  Ventilator DT T RMC 1       ERV wired remote control PCB    WI SW2 SW SW             COM2          Setas 0                 ERV wired remote  control  Master              ERV wi               X975   Set as 1                      remote          contro    Slave     2 ERV wired remote controls control the ventilator which is    connected to the COM2 communication cable        Initializing the Communication       at  4   l      z   iw       The communication between an individual ventilator or a group                of ventilators and an ERV wired remote control must be initialized  x  M s Test External Ctrl   Heater Damper  when there is an additional ventilator to be connected  entral 2Remote   Humidification  Mins   Heat EX    oo g g          Auto       Press f
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
1769-UM007D-EN-P, CompactLogix System User Manual  FIRS User Guide - Alberta Innovation and Advanced Education  Para instalar uma coluna capilar com a entrada PTV      SLA-HE20取扱説明書 [更新済み]    取 扱 説 明 書  Manual_Usuario_d-Copia_20W_Portugues ok  Mode d`emploi des partitions et fichiers audio L`essayer    Copyright © All rights reserved. 