1. recovery system to prevent damage when missing password When you forget the password which has been set to the HMI this HMI can execute RUN AP Calibrate operation but cannot execute BlOS Download AP Clear SRAM operations When the users want to download new AP without password please set all DIP switches to off SW1 6 Off When turns on HMI again the HMI will display the clean all AP and old password screen After proceeding this procedure the HMI can be operated normally again A 8 PanelVisa Industrial Touch Panel PV Installation manual Startup Test When turns on HMI it will display self testing screen After completed HMI will show the system menu HMI BIOS B1 1 CERMATE TECHNOLOGIES S N 037LK2E0601234 checking BIOS Checksum Error Parameter Error RTC Function Error DIP SW 6 1 111100 FigureA 1 When there are checksum errors that could be RTC data missing battery failed or AP not being downloaded HMI BIOS B1 1 CERMATE TECHNOLOGIES S N 037LK2E0601234 DIP SW 6 1 111100 FigureA 2 The HMI startup self testing _normal When turns on HMI system will automatically execute hardware testing first to make sure hardware are normal or not The result will show on the screen Figure A 1 A 2 If there are problems the HMI will not communicate with P L C normally When losing electricity during downloading or the PC breaks off downloading after restarting the HMI it will show Firmware Memory Chec
2. 3 4 5 6 8 115 Net Weight 0 30 Kg 0 26 Kg Cooling Natural cooling A 2 PanelVisa Industrial Touch Panel PV Installation manual PV057 LST PV057 BST PV057 TST Monochrome blue mode STN LCD Color mode TFT LCD 16 gray levels 256 colors 5 7 diagonal 5 6 diagonal 320x240 320x234 CCFT Life time is 20 000 hours under 25 C and 85 RH humidity Analog resistive type Max Number of switches are 40x30 Chemically strengthened glass backing panel Over 1 million point activations Hard coat is resistant to most solvents and chemicals COM1 9pin RS232 RS422 RS485 Communication Ports COM2 9pin RS232 COM2 Terminal 4Pin RS422 RS485 ProfiBus Port Optional with extension card 0 5mm displacement 10 55Hz 2hours per X Y and Z axis ectrostatic Discharge Test PanelVisa fe Outlet and Cut out dimensions The outlet and cut out dimensions of PV037 LSK are shown as following Smm ese ENT 27 9mm 4 9 mm gt cut oul 159 5 0 5 mm The outlet and cut out dimensions of PV057 LST BST TST are shown as following cut out 132 540 5 mm A 4 PanelVisa Industrial Touch Panel PV Installation manual Installation Before setup HMI please cut a hole according to the cutout dimension Please see below pictures for your installation reference
3. Industrial Touch Panel PV Installation manual PV037 PV05 7 Installation manual Among the automation control devices PanelVisa series is a high function but cost effective Panel Besides most basic functions it supports drivers of most PLCs invertors and temperature controllers on the market It is not only equipped with standard compact plastic case but also provides customized key types for users to design their favorite ones PanelVisa satisfies many kinds of design such as emergency buttons with various buttons Thus PV series can concur harsh environments to meet customers needs and welcome by tool machines specified function machine designers PanelVisa PV037 Specifications ltems PV037 LSK PV037 LST Disblav Tvpe Monochrome blue mode STN LCD Monochrome blue mode STN LCD Beye 16 gray levels 16 gray levels Display Size Number of Pixels Display Adjustment Back Light ouch Screen yes witch Key nput Power PU RISC 32Bit CPU lash Memory 1M Bytes ystem working Memory Battery Backed Memory thernet Port yes xtension Bus Port X ront Panel Seal Operating Temperature torage Temperature Ambient Humidity 20 90 RH non condensing Vibration Endurance 0 5mm displacement 10 55Hz 30Min per X Y and Z axis directions hock Endurance Radiated Disturbance Test ectrostatic Discharge Test RF Electromagnetic Field Test urge Immunity Test EN61000 4 5 1995 MC Test Report EN55022 EN55024 EN61000 3 2 3 EN61000 4 2
4. PV037 LSK 159 5mmx88 5mm PV037V LSK 88 5mmx159 5mm PV057 LST PV057 BST PV057 TST 174 5mmx132 5mm How to install the HMI Put the HMI to the cut hole and sew the lock screws at the four assembling holes on the HMI with average strength form the rear side Please do not sew too tight and without equational strength or it will damage the touch panel PanelVisa A9 The operation of the Key Panel and Touch Panel PV037 a kind of key panel equipped with a 3 7 160 H x80 V resolution LCD display a 22 keys membrane or an analog input touch panel allows users to design various applications If the touch panel is not fixed in a right position set the DIP SW1 SW2 and SWS to off to execute the touch panel adjustment Please adjust it while needed and do not do the unnecessary adjustment The Key panel is equipped with 22 keys on the membrane Those keys are some for numeric entry and some for programmable function keys There are four function keys which can be assigned with various functions in any screen from the software The other 0 9 ten keys on the membrane provide numerical entering function They can also be locked temporarily Press ESC and ENT at the same time to lock the ten keys To unlock press ESC and ENT again For double key s application users can operate to press together ESC and F1 F4 to act as a programmable function keys The Panel will automatically judge the data format or up down settings to complete
5. everely affected by excess external noise levels and vibrations Use a cable at 2 mm AWG 14 to ground the equipment Ground resistance must be less than 100 2 class3 Note that the ground cable must not be connected to the same ground point as the power circuit Installation Mount the HMI from the front of a suitable preserved hole Attached the brackets behind Fasten the screw of the brackets with proper force Tightening too much may cause damage to the structure of the unit Input and Output signal lines must be separated from the power cables for operational circuits Use shielded cables or it may cause unpredictable problems Do not allow cut wires filling or shavings to fall inside a unit or block when drilling holes or connecting cables lines Environment Do not install in areas subject to excessive dust oily mist conductive dust corrosive gas or flammable gas Do not mount in areas subject to shock or vibration Do not mount in areas subject to high temperature moisture or rain f Indicated loss of life severe personal injury or substantial property damage will result if proper precautions are not taken A 16 PanelVisa
6. how Incorrect Model when the Model No is not set correctly in the AP data Please select a correct Model No from the software then download it again If the HMI shows Incorrect User ID Code then the hardware and software might not fit each other Please check the brand name of the HMI to make sure you purchased a right hardware A 12 PanelVisa Industrial Touch Panel PV Installation manual COM Ports Define The communication port COM1 of PV037 PV057 can use as RS232C RS422 and RS485 while COM2 as RS422 and RS485 The COM2 of PV057 can use as RS232 RS422 and RS485 Please make the right connecting cable according to the specifications About the cable connecting figures of the HMI to other P L C please refer to the P L C manuals Communication port COM1 in HMI is a DB 9P Female COM1 pin definitions Pin Function Pin Function RS 422 TX and RS 485 RS 422 TX and RS 485 e 3 4 3 RS 232TXD BT RS 232CTS _ _ 4 RS 422RX 9 RS 422RX S Signal ground COM2 4 pin definitions RS422 and RS485 AZ TH R RK TX IL IL IL 485 4 Z PV057 communication port COM2 is a DB 9P Male COM2 pin definitions Pin a farsas fe Rsa 3 RS 232TXD_________ 8 RS 232CTS_ ___ _ _ _ _ A So fO Optional5V output 5 Signalground S S Extension Bus Port Its an Optional device This port can link with other extension modules for advanced functions Pa
7. ksum and Application Memory Checksum error It means there is an abnormal downloading To get a correct self testing result please execute a correct download AP procedure again If losing electricity during downloading or the PC breaks off downloading when upgrading OS it will surely cause download failure If you restart the HMI it will not display normal screens or even cannot be turned on In that case please set the DIP SW2 to OFF restart the HMI to get a default BIOS version B then execute the upgrading OS program to get a correct OS version Set the DIP SW2 to ON then the HMI can be turned on normally PanelVisa ee Startup Menu lf the DIP SW1 set to off after self testing the PV037 PV057 will show startup menu as following figures The Startup menu of PV037 is shown as below F3 Run AP Situation 2 When SW2 ON it will show the Panel Setup screen or customized Version screen PanelVis Panel Setup L_ General Copy To The Startup menu of PV057 is as below Situation 1 When SW2 OFF it will show the default BIOS Ver B Update OS A 10 PanelVisa Industrial Touch Panel PV Installation manual Situation 2 When SW2 ON it will show the Panel Setup screen or customized version screen PanelVis Panel Setup PanelVis Panel Setup Update OS To receive new AP OS Ver from COM Port Yes 1 To Copy AP to another HMI from COM1 2 Yes 1 Clear battery back
8. nelVisa LCD Adjustment PV037 To adjust the LCD contrast adjust the LCD adjusting knob from the PV037 rear side The PV037 is equipped with high luminance LED backlight so adjusting the LCD brightness is not necessary PV057 To adjust the PV057 LCD brightness Blue mode STN Color STN LCD TFT model can not be adjusted the brightness press General from PV057 Panel Setup screen or press LCD Testing from Settings in BIOS B From LCD Brightness press Increase Brightness to increase the brightness press Decrease Brightness to decrease brightness press Save Brightness to save Press OK to return to system screen General Check Battery Enable Screen Saver Time minutes 0 Enter Panel Setup Mode Enable Communication Setting Default Update OS Start up Language Pa Figure A 4 PV057 Panel Setup screen_ LCD brightness adjustment A 14 PanelVisa Industrial Touch Panel PV Installation manual Power and Grounding Specifications Use DC24V as PV037 power input The power consumptions are as following table To ensure the PV037 PV0O57 hardware working properly to avoid outside electromagnetism noise please ground the power source properly ltems Models PV037 LSK PV037 LST PV057 BST LST PV057 TST 24VDC 10 6W 24VDC 10 10W Sine Fine Power grounding caution The products are all equipped with power terminals and lock assembling sets The operating procedure is Screw
9. off the power terminal 2 Peel the 24V wiring 1 25mm for 1 cm then plug in the power terminal 3 Use line screw driver to screw the power terminal tight Package content We are appreciated for your purchasing our products Our standard package should be equipped with 5 items as following Please check after receiving it If there s any shortage please refer to the suppliers PV037 PV057 unit x 1 PV037 PV057 HMI Hardware Power terminal x 1 power terminal Communication terminal x 1 4 pin communication connector Installation screw nuts x 4 Lock for assemble with screws PV037 PV057 Installation Guide x 1 Installation manual Cautions lf this product is used in a house radio wave interference might occur to other devices In the case that it does occur the user is requested to try a variety of remedies to solve the problem PanelVisa Power source PV037 PV057 is equipped with DC24V input power If the supply power is other than DC24V whatever less or excess it will severely damage the HMI Therefore check the switching power supply supporting the DC power regularly To avoid electronic shock be sure the Power Cable is unplugged from the power outlet when connecting the cable to the HMI Grounding From the FG terminal at the rear side of HMI please make sure the grounding is made exclusively When the FG terminal is connect be sure the wire is grounded Without grounding the operation of HMI may be s
10. orts checking the serial number from the HMI to assure a complete after service The unique two BIOS system patent design In our past experiences the HMI will not be able to run normally or even not be turned on the system due to the unstable electricity during operating With the two BIOS system customers need not send the damaged HMI back to the factory Customize logos and User ID codes are available Even for the small amount industrial products this function let the customers have their own operating panel to complete an integer design Automatically data download and communication port COM1 or COM2 detection No need to setup With BIOS recovery system while missing password to prevent system blocking due to missing password PanelVisa A DIP Switches setting PV037 PV057 DIP Switches setting Oo swi t is C CSCSCSCSSS Stem Meet turns on Display system menu when turns on Not go to ON LINE communication a ae ran Emergency recovery the HMI BIOS to default value Set to default OS version or customized OS version Set to default BIOS version B a HMI operation mode Supports special functions for customized BIOS version ON OFF To execute HMI Communication testing program SW1 2 must set to Off en e To execute Key adjustment program or Touch adjustment program SW1 2 must set to Off To execute HMI application program a ees U E o D a The PV037 PV057 has a BIOS password
11. the data input PV057 is a kind of touch panel equipped with a 5 7 320 H x240 V size LCD display and an analog input touch panel It accepts to have maximum 20x15 touch buttons in a screen The shapes of touch keys should be rectangles with sizes from minimum 16 H x16 V pixels to maximum 320 H x240 V pixels A 6 PanelVisa Industrial Touch Panel PV Installation manual FEATURES 1 High Quality Control and 100 Product Test 2 Provides customized option keys design 34pin Connector 8x4 32 matrix keys and 8 individual function keys There are 40 keys in total 3 Built in Fanless Reliable and High Function RISC 32 bits CPU 4 Provides long life LED backlight Color TFT LCD 5 Provides 128KB 1 MB battery backup memory for Alarm Recipe Data Recording Using Options 6 Supports Multi Languages Unicode amp BMP gt JPG gt GIF graphic formats 7 Provides accommodative Software PanelMaster 8 Customize Logo Membrane Design and BIOS for users PV037 PV057 is a compact HMI with BIOS password protected function This special function can be used to prevent the inside application data from being stolen or destroyed The BIOS password is not set as a default situation With BIOS upgrade function wherever in the world whenever the HMI needs to be updated new functions this function supports upgrading without sending back to the factory With serial number in the BIOS as an ID number of the HMI Supp
12. up data memory Yes 1 Press Run AP or ENT to communicate with P L C None 2 HMI keys and hardware functions testing None Check HMI LCD Display None Press ESC to return HMI hardware self testing None 1 If sets a BIOS protection password to HMI then the HMI will request the users to enter BIOS password 2 If sets a login user password in AP when selects Run AP it will request the user to enter BIOS password PanelVisa Download AP To download AP to HMI please make sure the download cable is connected properly During the operating or in startup menu the HMI is ready to receive AP data sent by PC automatically When download AP the SW2 ON Panelis Panel is Panel Setup FigureA 3 The HMI downloading data from PC screens 1 Connect the PC COM1 or Com2 and HMI with a PC download cable HMI Connector PC RS232C HMI Connector PC Connector 9 pin Female 9 pin Female 9 pin Male 9 pin Female RAD TxD TAD 3 3 _ __ _ 3 aie o SG 7 7 i E CTS CTS RTS a L RTS L L HMI COM2 PC COM HMI COM1 PC COM Serious Caution Be sure turn off the power before connecting or it will damage the HMI communication components 2 The HMI will judge the data correctness during downloading AP When the PC sends AP data to HMI the HMI will show download AP screen and display related information automatically to receive data The HMI will s

Download Pdf Manuals

image

Related Search

Related Contents

Kanex HDBASE100M  BDS-256 Commissioning Procedure and Acceptance Test for the  ESTACION DE LA TEMPERATURA RADIO CONTROLADA  Mode d`emploi METTLER TOLEDO Titrateurs DL77 / DL70ES / DL67  Ouvrir le document  AC-5000 .User Guide - Virdi-GSS  anile-8r - AnyTone Tech  取扱説明書  Sony ILCE-5000L/B Marketing Specifications  PELLBOX SCF  