Home

PROGRAMMING AND INSTALLATION MANUAL

image

Contents

1. Zone 16 name ce seess CA10 plus LCD S keypad 23 Texts Symbols L output names Output 1 name Output 2 name Output 3 name Output 4 name Output 5 name Output 6 name System ok System Armed Silent Arm Arming Arming Silent Disarming Zones bypassed Alarm Fire Alarm Alarm Memory Fire Memory Alarm off Trouble Entry Time Exit Time Time Left Wait for data led on CA 10 e led off numbers of zones to display 24 Programming and Installation Manual SATEL Settings Reset Defaults Test te LCD standard Zone ok Bypassed Violated Tampered Alarm memory Tamper Memory Part 1 zones selection Part 2 zones selection Part 3 zones selection Part 4 zones selection Date and Time Format State Format LCD Backlight Keys backlight Keypad address GOTO functions Options Default names Default Texts Default Settings CA10 plus LCD S keypad 25 Partition names The functions are used to program partition descriptions which are displayed when GOTO function is called The name of the current partition is displayed when the key W is pressed Partition users names User names are used when the system is armed disarmed or when the event log is reviewed Zone names The names are used when event log is being reviewed violations and alarms occur and when service functions used to set zone parameters are called Output names The names are used to indicate d
2. 3 LED D partition 4 4 Programming and Installation Manual SATEL The function of LED controls changes after user or service mode is entered according to the principles of status communicating by LED keypads c f CA10 plus with LED keypad user manual The keypad has 12 keys labeled according to telephone data input standard Additional four arrow keys support MENU navigation and selecting functions After a function has been chosen the arrow keys support programming The keys and gt move the cursor the key A backspaces deleting the character that proceeds the cursor and the key W toggles the data input mode insert or overwrite Modes The keypad can function in one of the following three modes 1 Text mode the first line displays system date and time The second line displays system status messages which can be standard e g SYSTEM OK ARMED etc or defined by the installer e g SERVICE 505 34 77 instead of SYSTEM TROUBLE In this mode it is possible display all current messages alternately or according to priority In priority mode only the highest priority message is displayed e g ALARM In non priority mode all relevant messages are displayed one after another in a closed cycle e g ALARM and ARMED by turns 2 Mixed mode LCD standard the first line displays system date and time while in the second line the status of all 16 zones is being monitored The status of each zone is displayed as a single cha
3. be tested Starting this function restores default keypad parameters To preserve your own parameters it is necessary to write them into computer before testing and after testing they should be again programmed from the computer Pressing key after end of testing will restart keypad Computer supported programming All keypad parameters can be programmed from the computer by means of the DLOAD10 program version 1 00 03 and later working in the WINDOWS environment The program serves also the previous versions of LCD keypads Use the cable for panel programming to connect the keypad to the computer RS 232 port No initialization is required the keypad will automatically respond to DLOAD10 commands CA10 plus LCD S keypad 31 Specifications Minimum power supply voltage 11V Maximum power supply voltage ennen 16 V ee st ne RS iin tient nln en AA a tn edd at 170 mA Current drawn ee ele 30 mA Eengel ee 20 mA LED controls on all ALARM TROUBLE ARMED aaaaaaeneeneneeenennennnnnnnnnenn 20 mA display back lighting 1 2 Iweak 35 mA display full back lighting ss 100 mA DIMENSIONS Fes EEE NRA RE ARE AN A PAS E ERG CAG NN AD PR se ne Rene es 115x95x25 mm 32 Programming and Installation Manual SATEL HISTORY OF THE MANUAL UPDATES The updates below refer to the manual for the LCD Keypad with software version 3 00 Program version 3 01 3 06 No changes 01 2003 3 0
4. 7 3 08 07 2003 3 10 e The service functions menu has been enhanced by new functions FS 125 p 17 FS 134 137 p 15 and FS 138 139 p 14 e New option that applies to possibility of activation the functions assigned to arrow keys has been added p 29 e The description of keypad service function Reset Defaults has been added p 30 e New keypad service function Test has been added p 30 Date Description of updates e Service function menu updated FS 133 added to system codes p 15
5. CD S keypad 15 Partition report codes 69 70 71 72 73 74 75 76 77 78 79 80 Partition 4 events assignment to station 2 System report codes Partition 1 events Partition 2 events Partition 3 events Partition 4 events Partition 1 events assignment to station 1 Partition 2 events assignment to station 1 Partition 3 events assignment to station 1 Partition 4 events assignment to station 1 Partition 1 events assignment to station 2 Partition 2 events assignment to station 2 Partition 3 events assignment to station 2 System events set 1 System events set 2 System events assignment to station 1 System events assignment to station 2 Test transmission time AC loss report delay Guard control report codes 133 134 135 136 137 Time of test transmission every Zone bypass codes Zone unbypass codes Prefix for extension of identifiers TELIM TELIM codes 16 Programming and Installation Manual SATEL Tel messaging Tel number 87 Telephone number 1 88 Telephone number 2 89 Telephone number 3 90 Telephone number 4 91 Telephone number 5 92 Telephone number 6 93 Telephone number 7 94 Telephone number 8 95 Partitions and messages assignment 6 Message 1 7 Message 2 8 Message 3 Pager messages is 9 Message 4 Messages HEX mode 119 Message 1 HEX a 120 Message 2 HEX HEX O 121 Message 3 HEX 122 Message 4 HEX Messaging options 100 Te
6. PROGRAMMING AND INSTALLATION MANUAL Keypad LCD S software version 3 10 CA 10 plus Gael GDANSK ca10plci_s_e 09 03 N WARNING Due to safety reasons alarm system should be installed by qualified personnel only Because alarm system may contain hazardous items its components should be kept out of reach of unqualified personnel In order to avoid the risk of electric shock read carefully this manual before proceeding to installation Any connections should be made in deenergized state only i e with power supply disconnected Making any construction changes or unauthorized repairs is prohibited This applies in particular to modification of assemblies and components The SATEL Company recommends that operation of the whole alarm system be regularly tested However a reliable alarm system does not prevent burglary assault or fire from happening it only diminishes the risk that such a situation will cause no alarm or notification History of the updates to this manual is attached at the end hereof CA10 plus LCD S Keypad v3 10 The keypad designated with the symbol LCD S is a new design version having reduced dimensions of housing and display of the hitherto manufactured LCD keypad Its operation is based on the identical program as the above mentioned LCD keypad LCD keypad with firmware version 3 10 is compatible with CA1Oplus alarm panel with firmware version 4 7 It s also backwards compatible
7. artition names help to control multipartition systems with a single keypad While reviewing the event log descriptions of events and occurrence times are displayed in text format User functions can be accessed by selecting them from an appropriate choice list Service programming is easier The complete set of keypad functions is available when it is connected to the panel CA10 of version v3 0 or newer designed for LCD keypads All service functions of CA 10plus with firmware version 4 7 are available with use of LED keypad LCD keypad firmware version 3 10 or later and with use of computer running Dload10 software in version 1 00 14 or later CA10 plus LCD S keypad Keypad description The keypad displays information on a 2 line LCD display 2x16 characters with backlight ee and six additional LED controls 5 Sep l3z26 41 LED controls functions System OK alarm signals occurrences of alarms armed C Am ee eme trouble the LED is blinking when the control panel detects a technical problem or a telephone messaging trouble armed A B C D partition status signaling blinking while the alarm control is off signals exit delay running control stays on when the partition is armed r trouble Figure 1 View of LCD S The LEDs marked with letters B C D correspond to numerical denotation of partitions available in the system LED A partition 1 LED B partition 2 LED C partition
8. ass zones Zones sensitivity 25 26 Zone type Reaction type Zone options 28 29 30 Entry delays Maximum violation time Minimum no violation time Output OUT programming Zones assigned to OUT 1 Output OUT programming2 Zones assignee to OUT2 Output OUT programming3 Zones assignee to OUT3 Output OUT programming4 Zones assignee to OUT4 Output OUT programming5 Zones assignee to OUT5 Output OUT programming6 Zones assignee to OUT6 14 Programming and Installation Manual SATEL Monitoring Stations Identifiers Zone report codes TITT LIT TITI Station 1 telephone number Station 2 telephone number Station 1 transmission format Station 2 transmission format Monitoring options Zone events ID for station 1 Partition 1 events ID for station 1 Partition 2 events ID for station 1 Partition 3 events ID for station 1 Partition 4 events ID for station 1 System events ID for station 1 Zone events ID for station 2 Partition 1 events ID for station 2 Partition 2 events ID for station 2 Partition 3 events ID for station 2 Partition 4 events ID for station 2 59 System events ID for station 2 138 VISONIC adar 139 VISONIC test Zone alarm Zone tamper Zone trouble Zone violation Zone restore Tamper restore Trouble restore Assignment to station 1 Assignment to station 2 CA10 plus L
9. dress Using the 0 and 1 keys enter the proper address and then press the key The keypad will display the text Set addresses FS 124 1 Yes Press the 1 key to automatically perform the FS 124 service function and save the settings The functions of the other keypad jumpers have been replaced by the options available in the submenu of the LCD S keypad service functions LCD keypad Settings gt Options These options have the following descriptions D Long illumination T jumper function if not selected the option will set the 40s time and when selected it will set the 150s time of waiting for no key depressed e g when reviewing the zones state after holding down the W key the review will be ended by the keypad after the time set with this option if no key is pressed Permanent illumination L jumper function if selected this option will cause a permanent backlighting of the keypad and a dim permanent backlighting of the display irrespective of the keypad settings indicated in the service mode As the LCD S keypad consumes more power than the LED keypads especially when the illumination of keypad and display is on it is important that resistance of the power cables and grounding conductors be taken into account when planning the cable layout CA10 plus LCD S keypad 9 In the case of standard 8x0 5 cable to ensure proper keypad function the following number of wires versus the panel keypad di
10. estination of panel outputs They are displayed when event log is being reviewed or output functions are being programmed in the service mode Texts Standard system messages like alarm armed etc can be modified with this function according to user preferences and requirements of a specific installation 26 Programming and Installation Manual SATEL CA10 plus LED standard characters In zone monitoring mode according to LED standard the character corresponds to LED control on and corresponds to LED off It is possible to change these characters some other The parameter number of zones to be displayed is used to limit the number of monitored zones in the case when some are not used c f service functions 12 15 control panel user manual This can be necessary after switching to another partition with GOTO function LCD standard characters Characters which signal various zone states in zone monitoring mode LCD standard can be modified here The choice of zones option can be used to eliminate non existing zones NOTE The choice of zones is used to select zones which are to be displayed as violated or alarming zones by corresponding panel functions This is primarily used in text mode to limit the displayed names of zones to the set of zones of the current partition to which the keypad is currently attached CA10 plus LCD S keypad 27 Time format Display back light Keypad back light The ab
11. ion Notes e f more than one LCD keypad is installed in the system function GOTO settings should be separately programmed in each keypad In the case of installation with an LCD S keypad expanders adapted to LCD keypads should be used software version 2 manufactured since February 1998 Older expander versions will also operate with LCD S keypads but will not support multipartition systems CA10 plus LCD S keypad 29 The functions enables setting some additional parameters such as display exit delay time left exit delay sound signaling type beep on key pressed change back lighting on key pressed how long to wait for pressing next key 40s 150s is illumination of keypad and display to be permanent are functions assigned to arrow keys to be active Status priority parameter determines the way system status is displayed in the text mode If it is off all relevant messages are displayed one after another in a closed cycle If it is on only the highest priority message is displayed The following priority levels are assigned by default starting with the highest 1 fire alarm burglary alarm armed or silent armed fire alarm occurred burglary alarm occurred exit delay N O1 BB W D entry delay 30 Programming and Installation Manual SATEL Reset Defaults The function restores default parameters of keypad Test The function enables keypad functioning correctness to
12. l queue and attempts 101 Rings to answer 117 Tel line loss recognition delay 118 PAGER station parameters Timers 102 Timer 1 103 Timer 2 104 Timer 3 105 Timer 4 106 Timers functions CA10 pl us LCD S keypad 17 Special functions Event log 107 Default data restore 108 Clear event log 109 Factory service downloading data 110 Factory codes restore 111 Keypads addresses 112 Local downloading start via RS 232 124 Auto configure keypads addresses 125 Outputs testing 131 Additional options BIT 132 Programming of correction of clock DEC 113 Event log print 114 Alarm log print 115 Trouble log print 116 Partitions events log print Event log review LCD Keypad submenu see Keypad service functions Quit service mode Notes e To call a function currently pointed by the display arrow press or e To cancel a function press or or sometimes the combination of and this depends on the type of the function in some functions the keys and lt are used to edit data It is possible to call a function straight by entering its number without using the menu Function FS 124 called from LCD keypad programs keypads addresses and makes additional configuring actions The system require to call this function from each connected LCD keypad Do not change manually keypad addresses with function FS 111 18 Programming and Installation Manual SATEL Bit functi
13. ning keys function depend on the mode Key Numeric mode function Text mode function a delete proceeding character previous Character in the alphabet WS 2298 toggle insert overwrite next character in the alphabet 20 Programming and Installation Manual SATEL The text mode is signaled by in the upper right corner of the display Use numeric keys to enter characters according to the table Lowercase characters are obtained by pressing the corresponding numeric key twice To cancel programming a description press sequentially and while in the numeric mode Keypad service functions Keypad service functions are available in the panel service mode through the submenu LCD Keypad at the top level of the Service mode menu The structure of the submenu follows CA10 plus LCD S keypad 21 LCD KEYPAD SUBMENU Names Partitions Partition 1 name Partition 2 name Partition 3 name Partition 4 name Partition 1 users names User 1 name User 2 name User 3 name User 4 name User 5 name User 6 name User 7 name User 8 name User 9 name User 10 name User 11 name User 12 name Master user name seess L MASTER user name 22 Programming and Installation Manual SATEL Zone names L MASTER user name Zone 1 name Zone 2 name Zone 3 name Zone 4 name Zone 5 name Zone 6 name Zone 7 name Zone 8 name Zone 9 name Zone 10 name Zone 11 name Zone 12 name Zone 13 name Zone 14 name Zone 15 name
14. ons After a bit function is called the keys lt gt will change the cursor position and the keys AW will the value of the bit at the cursor position It is also possible to enter the desired bit number with the numeric keys Bit numbers 10 16 are entered by pressing followed by the key with the second digit The combination of and terminates the function In this way variables of type zone list are programmed e g Programming partition zones Bit functions with a list After a bit function with a list is called in the first line of the display the function name will be shown while in the second line the first position in the bit switch list is displayed e g System options The character H indicates that the option is on To change the switch state press any numeric key The keys AY will scroll the switch list Multiparameter functions In the case of functions which are used to program several parameters The keys AV choose the parameter to be modified the key lt deletes the character which proceeds the cursor and the key cancel any changes to the currently edited parameter Parameter values are entered with numeric keys To enter HEX digits A F press followed by one of the digits 0 5 CA10 plus LCD S keypad 19 Editing descriptions During programming of text format messages the keys dk control the cursor toggles the mode text mode numeric mode and confirms the entire text value The remai
15. ove functions to choose the format of date and time to be displayed in the first line of the display and the back light status of the display and the keypad Symbols to be used 0 back light off 1 2 weak back light 1 full back light auto back light is turned on after a key is pressed and then turned off after time set with use of option Long illumination 40 or 150 seconds The function selects the panel s operation mode e text mode descriptions system status is communicated by means of textual messages e zones according to CA10 plus mode status of maximum of 12 zones is displayed according to the list programmed with panel service functions FS12 FS15 e zones according to LCD mode status of maximum of 16 selected zones is displayed indicating violations alarms tamper conditions alarm log etc 28 Programming and Installation Manual SATEL GOTO function GOTO function performed on LCD S keypad is easier then on LED one LCD S keypad allows zone switching without returning to the base zone the key This menu selects partitions to which switching with GOTO is allowed Activation of the function needs programming service function of LCD keypad In menu Settings Function GOTO we can specify the partitions to which we can go with GOTO function After confirming the partitions selection LCD keypad will perform FS 124 service function which will set addresses of LCD keypads proper for the current configurat
16. racter e g zone OK N zone violated After a change in the system status e g after arming the system the keypad displays the status as in the first mode and after a while turns to zone monitoring CA10 plus LCD S keypad 5 3 Mixed mode LED standard this mode is similar to the second one The second line is used to monitor the status of 12 zones as in the case of LED keypad Operating mode 1 or 2 is recommended for the LCD S keypad The user can temporarily change the display mode switching over between the text mode and the zone state display by holding down the Wkey LCD S keypad installation The keypad is designed to operate indoors in normal humidity It should be mounted straight on a flat surface Attention The LCD display is fragile It can be damaged when dropped 6 Programming and Installation Manual SATEL Connecting the keypad KPD KPD DTA DATA CLK1 or CLK2 or CLK3 or CLK4 COM COM CLK ady Yla VD WOO Z1 to detector Additional Z2 to detector System zones IZ Figure 2 Schematic view of the keypad board including designations of wire terminals version LCD S V1 6 The connections are made as in the case of LED keypad The panel can operate both with LCD and LED keypads in any configuration The only limitation is that parallel connecting any LCD keypads to the same CLK panel port is not allowed CA10 plus LCD S keypad T Only zone expanders wi
17. stance should be used Distance Connection Number of wires KPD and COM 2x1 EECH CLK and DTA signals 2x1 KPD and COM 2x2 KAE CLK and DTA signals 2x1 KPD and COM 2x4 EH CLK and DTA signals 2x1 Note the keypad power supply voltage measured between KPD and COM on the keypad side must not drop below 11V when the back lighting is on After the control panel power up the keypad can display message Change panel s EPROM or set the correct keypad address This is usually because the keypad address is different than the one programmed in the panel In this case start the panel according to the instructions in CA10 plus Programming Manual section Starting the Control Panel NOTE We recommend keypads CA 10 LED M v1 2 and CA 10 LED S v1 2 or newer to be used because older keypads LED M and LED S may work incorrect with keypad LCD v3 08 and next version 10 Programming and Installation Manual SATEL Service mode After the service mode code terminated with or is entered the panel enters the service mode This is signaled in the keypad by the following message Service mode Menu MY E gt Press any arrow key to enter multi level service mode menu which provides easy access to service functions The functions are grouped by subject The arrow keys AY scroll the list of the current level of the menu The key expands the next lower in hierarchy menu level The key turns back
18. th version 2 are allowed label dated February 1998 or later Since LCD keypads take larger current then LED keypads especially when back lighting is on wire resistance must be taken into account in the case of supply and earth cables The LED keypad address setting jumpers DCBA have been replaced in the version 3 00 with a parameter programmed by means of the service function of the LCD S keypad The keypad address can be changed in two ways 1 Directly skipping the service code e Disconnect the keypad power supply and the data bus wires CLK DATA e Short circuit the CLK and DATA terminals of the keypad e Switch on the keypad power supply The following text will be displayed Keypad hardware address 1001 the default value corresponding to the jumpers read out in the ABCD sequence e Using the 0 and 1 keys enter the proper address and then press the key The Address set text will be displayed on the keypad e Connect the keypad to the control panel in appropriate way CLK DATA NOTE For correct handling of the LCD S keypads by the CA 10 plus control panel the FS 124 function must be performed on each of the LCD S keypads connected to the panel Programming and Installation Manual SATEL 2 By means of the keypad service functions Activate the control panel service mode SERVICE CODE Select in turn the items in menu of displayed functions gt LCD keypad gt Settings gt Keypad ad
19. to the previous higher in hierarchy level CA10 plus LCD S keypad 11 For example if Monitoring is selected pointed by the arrow on the display then pressing gt twice followed bye pressing twice will result in the following sequence Monitoring Stations amp options Ch Station 1 tel no 4 Stations amp options Monitoring The following pages show the structure of the menu The functions programming the LCD S keypad are grouped in a separate menu described later in this guide 12 Programming and Installation Manual SATEL SERVICE MODE MENU Basic Options Partitions definition GO JO O1 P D N Service code Panel identifier Computer identifier Computer telephone number System Options Global times Counters Counters timers Zones of partition 1 Zones of partition 2 Zones of partition 3 Zones of partition 4 Zones displayed on keypad1 Zones displayed on keypad2 Zones displayed on keypad3 Zones displayed on keypad4 Partition 1 auto bypassed zones Partition 2 auto bypassed zones Partition 3 auto bypassed zones Partition 4 auto bypassed zones Partition 1 options Partition 2 options Partition 3 options Partition 4 options Partition 1 exit bypass zones CA10 plus LCD S keypad 13 Zones Outputs 128 129 130 Partition 4 exit bypass zones 24 27 Partition 2 exit bypass zones Partition 3 exit byp
20. with CA10plus alarm panels firmware version 3 0 or newer The LCD keypad is designed to control the Satel CA10 plus alarm panel It supports everyday use as well as programming the panel Easily readable liquid crystal alohanumeric display provides accurate information on the system status or the currently performed user operation and thus helps avoid errors While programming the panel required functions can just be selected from the displayed list The panel has its own processor which controls the user panel communication It analyses data from the entire alarm system and thus the keypad can simultaneously display the status of all partitions The keypad design with software in the version 3 00 has been changed as compared with the previous version 2 04 The keypad address jumpers as well as the jumpers described as T and L have been removed and replaced with an optional software setup of the corresponding parameters see details in the section LCD Keypad Installation Programming and Installation Manual SATEL Panel CA10 plus with LCD S keypad acquires new features System status messages displayed in text format provide easy readable information on essential events Zone descriptions defined by the installer help to determine the alarm cause Visible system clock and date help to ensure error free function of the panel LCD keypad can display the status of all 16 zones which helps in controlling large alarm systems P

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SFD-321B/LFHSE floppy drive  30020 GRUARO-ITALY - VIA DELL`INDUSTRIA 7  New Optimization  VIADRUS HERCULES Green Eco Therm d Mode d`emploi et d  Kenmore 596.50019100 Refrigerator User Manual  BDW-811NS - コイズミファニテック  Manuel d`instruction  Recommendations for Minimal Wi-Fi Capabilities of  Rassemblement 2011 Méditerranée - Hyères les Palmiers <  User manual - factline Community Server  