        OPERATORS MANUAL (Universal Receiver uRx
         Contents
1.    Outdoor Surveillance    User Manual    Universal Receiver uRx       A Division of TRAP INTERNATIONAL C C     OPERATORS MANUAL   Universal Receiver uRx     Introduction  Congratulations on your purchase of a Roboguard  Universal Receiver     Installation and wiring   The installer   s manual is available for people  wishing to do a self installation  Be careful as  unqualified people can damage the device at  installation and this damage is not covered by our  warranty     General Operation   The Universal Receiver  uRx  is used to remotely  trigger the operation of electronic devices from  Roboguard signals  The uRx can be    taught    to  respond to any particular roboguard radio  message  Once the uRx has learned a roboguard  code  every time it receives that radio message  it  will respond by triggering the connected device   This connected device may be an alarm system  a  camera system  a siren  an SMS module  in fact  any device capable of being triggered by an  electronic signal    In the example above a uRx can be programmed  to respond to a radio message from a Roboguard  handheld remote  This handheld remote can then  be used as a panic button and the uRx can be used  to operate an SMS module to send an sms call for  help in response to the panic signal  Another  popular use will be to open a garage door    Your installer must connect the uRx to a power  source and to the device that you wish to trigger   The installer must also configure the options on  the uRx 
2. clearly indicated on the unit  The 2 way  dip switch is used to configure the polarity  SW1   and the Switch timing  SW2   Another version the  uRxL should be used for latching requirements   The I O1 and I O2 terminals are not used in this  device     The raw data from the radio is also available at the  connector on RXO for connection to keypads or  other decoder devices     The unit has 3 LEDs  one displaying RF data  one  showing the output  NC  status and one used for  showing the status of the unit which will vary its  flash rate for different option settings     Installation   Position the uRx in a position suitable for the  reception of radio signals from the intended  source  Check for radio interference by observing  the flashing of the RF LED  If the RF led is flashing  brightly and continuously then you may have a  problem with radio reception  Confirm this by  transmitting from a roboguard product to see how  the RF led flashes for data reception    Obviously the device to be triggered will need to  be located closely     Wiring  Wire the uRx to  12V and OV  ensuring the OV is  common with the OV of the device to be switched    Wire the data line or the trigger  NC   outputs as needed    The NC output is an open collector low   side driver capable of sinking 500mA continuously   It can therefore be used to drive sirens  relays etc   Should it be used as a data output then a  typ 1k   pull up resistor will need to be used at the  connected device     Coding   As y
3. ou require the unit to decode a radio message  then you must teach the uRx the code of the  roboguard event by placing the unit into learn  mode and then transmitting the relevant signal   The device is placed into learn mode by using a  conductor  like a screwdriver  to short out the  program pads on the PCB  The program pads are  located next to the letter B on the PCB in the area  of the 2 way DIL switch    The status led will now remain on until the device  learns a valid roboguard code  Transmit the  desired code  tamper  remote or intruder   The  status led will reset back to flashing   If the unit is powered up with the programming  input shorted then the unit will erase all learned  codes     Configuration   Place the DIL switches in the required positions as  per the information in the connected device   s  installer manual and the table below      TON Jor  Function    Output polarity  Output trigger time       Testing   The installation must be tested for RF range and  for correct triggering of the connected device upon  transmission of the previously learned signal     POLARITY  TIMING    uRx AND uRxL    STATUS    RF DATA    OUTPUT    sed    No   lt u GO Gee    RF DATA OUT    Not Used  Not L    OV     12V    lector low side  sinking 500mA     ed via the  h to be normally   VE  OF out  or   open circuit       w Oo    0    emo SS    any  VE voltages directly to NC    dt  tiv  10   out    PLEASE NOTE  Do not connect    NC is an open co  iver capabl  can be configu  la
4. rity swit  tive  short   rmally inacti    int          2s    CONTROLLED  DEVICE  d  I  p  a  ni    w     a      o  oS  Q      Z  2         im  E  o  o       like a Keypad and  Universal Transmitter    RX DATA IN    Wiring Diagram    Note that this manual is written for people who have an  understanding of electrical systems and the  interconnection thereof  If you are not in this position  then we advise you contact an installer as you may  damage the product and void the Warranty     
5. to correctly trigger the connected device  and must marry the transmitter to the uRx  through a learning process    The uRx will flash its status LED at different flash  rates depending on the configured options as set    up by your installer     Maintenance  There are no user maintainable parts or  considerations     Support   Properly installed Roboguards do not false alarm   Ensure that your system is properly installed and  configured     Please visit www robogquard co za forum for online  support     Warranty   All Roboguards systems carry a 2 year factory  warranty  a lifetime warranty against UV damage  and the guards themselves carry a lifetime  warranty against lightning damage     Technical Details    Dimensions  104 X 64 X 27  Mass  100g   Current Consumption   _ 25 MA   UHF 433 92 MHz    Required receiver  Required Power Supply 12V DC  Colour  White    Packing Contents       Trap International CC  PO BOX 38113  Point  4069  Durban  South Africa    sales roboguard co za  www roboguard co za    ROBOEUARE    Outdoor Surveillance    Installation Manual  Introduction  The uRx can be used as a data receiver and as a  Roboguard Decoder  It will learn ANY roboguard  Signal  ie tamper  intruder  remote and Autotest   unlike the HQ and Keypad modules which only  learn tamper signals  Upon reception of the  learned signal the uRx will trigger a connected  device  Note that the uRx does NOT supervise the  radio link      12V  OV  RxData  RXO  and Trigger  N C  Pin   outs are 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Dakota Alert Inc. Portable Radio Multiple Use Radio Serice (MURS) Hand Held Transceiver User's Manual  installation guide and user manual  User Manual - nh  Ferngesteuerter 3,5-Kanal-Kampf-Hubschrauber „GH-35.fight“  Agilent Technologies 86100b Sprinkler User Manual  EGY-25LN  Reagents  Nokia 7710 Cell Phone User Manual  Optiheat economy_1-22e bis 1-33e  Acer 4410T Laptop User Manual    Copyright © All rights reserved. 