Home

Operating Instructions

image

Contents

1. down action allows you to turn off the system and allows you to cleanly stop all running services The keys have the following functions The current menu is left When the key is pressed a couple of times the modifications are discarded and the initial state will be displayed Those keys are used to switch between the different menus and or characters Pressing executes the configured action UTM 220 Operating Instructions Starting factory reset 1 Press the Enter key 2 Press the v key The following message will be displayed All data erased 3 Press the Enter key The following message will be displayed Are you sure With the up down keys you can select Yes y or No n 4 Press the Enter key to confirm your settings The factory reset action will now start Starting reboot machine 1 Press the Enter key 2 Press twice on the v key The following message will be displayed Rebooting 3 Press the Enter key The following message will be displayed Are you sure With the up down keys you can select Yes y or No n 4 Press the Enter key to confirm your settings The reboot machine action will now start Starting shut down 1 Press the Enter key 2 Press triply on the key The following message will be displayed Shutting down 3 Press the Enter key The following message will be displayed Are you sure With the up down keys you can select Yes y or No n 4 Press the Enter key to confi
2. you install the rails Vv Install the heaviest server components on the bottom of the rack first and then work up gt Allow the hot plug hard drives and power supply modules to cool before touching them Always keep the rack s front door all panels and server components closed when not servicing to maintain proper cooling UTM 220 Operating Instructions Rack Mounting Considerations Ambient operating temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore you should install the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature gt Reduced airflow Equipment should be mounted into a rack with sufficient airflow to allow cooling gt Mechanical loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern gt Reliable ground Reliable grounding must be maintained at all times To ensure this the rack itself should be grounded Particul
3. SOPHOS Simple Secure Operating Instructions UTM 220 UTM 220 Operating Instructions Foreword We are pleased to welcome you as a new customer of our Sophos UTM hardware appliances To install and configure the hardware appliance you can use the following documents Hardware Quick Start Guide Connection to the system peripherals in a few steps gt Operating Instructions Notes on the security and commissioning of the hardware appliance Administration Guide Installing and configuring the software appliance The Hardware Quick Start Guide and the Security Notes are also delivered in printed form together with the hardware appliance The instructions must be read carefully prior to using the hardware and should be kept in a safe place You may download all user manuals and additional documentation from the Support webpage at astaro com support security Symbols The following symbol and its meaning appears in the Hardware Quick Start Guide Security Notes and in these Operating Instructions Caution and Important Note If these notes are not correctly observed This is dangerous to life and the environment The appliance may be damaged The functions of the appliance will be no longer guaranteed gt Sophos shall not be liable for damages arising from a failure to comply with the security notes Designed Use The hardware appliances are developed for use in networks The UTM 220 model
4. ales Tel 61 2 9409 9100 Email sales sophos com au SOPHOS
5. ar attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc Rack Mounting Instructions To mount the appliance to the rack you need the delivered rack mount brackets There are a variety of rack units on the market which may mean the assembly procedure will differ slightly You should also refer to the installation instructions that came with the rack unit you are using Important Note Make sure you use the screws supplied with the rack mount brackets Using the wrong screws could damage the hardware appliance and would invalidate your warranty The rack model UTM 220 is not delivered with rails Please observe the mounting instructions for your rack 1 Attach the rack mount brackets to the appliance Place the appliance on a hard flat surface with the front panel facing you Attach the rack mount brackets to the left and right side of the appliance with the supplied screws Make sure the brackets are properly attached to the appliance UTM 220 Operating Instructions United Kingdom Sales North American Sales Tel 44 0 8447 671131 Toll Free 1 866 866 2802 Email sales sophos com Email nasales sophos com Boston USA Oxford UK Copyright 2012 Sophos Ltd All rights reserved All trademarks are the property of their respective owners Sophos Operating Instructions 02 12v1 dNA 2 Choose the rack location Leave enough clearance i
6. may be operated as a standalone appliance The hardware appliance can be used in commercial industrial and residential environments The UTM 220 model belongs to the appliance group A The hardware appliance must be installed pursuant to the current installation notes Otherwise failure free and safe operation cannot be guaranteed The EU declaration of conformity is available at the following address Astaro GmbH amp Co KG a Sophos company Amalienbadstr 41 Bau 52 16227 Karlsruhe Germany CE Labeling FCC and Approvals The UTM 220 appliance complies with FCC Class A CE C Tick VCCI and UL Important Note For computer systems to remain CE and FCC compliant only CE and FCC compliant parts may be used Maintaining CE and FCC compliance also requires proper cable and cabling techniques Operating Elements and Connections Sophos UTM 220 rev 5 SOPHOS GE See LCD and COM 8x10 100 1000 VGA fans LED power control keys 2XUSB Base TX ports LED power power switch hard disk hard disk Controls Power LED Display Green Power on Green HDD Hard disk access LEDS on each Ethernet connector 1 The Ethernet port is receiving power Link LED Green Constantly 2 Good connection between the Ethernet port and hub 1 The adapter and switch are not receiving power 2 No connection between both ends of network 3 Network drivers have not been loaded or do n
7. n front of the rack so that you can open the front door completely 60 cm 25 inches Leave approximately 80 cm 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing This product is for installation only in a restricted access location no capitalization dedicated equipment rooms service closets and the like 3 Slide the appliance into the rack 4 Attach the brackets to the rack with the appropriate screws not included Connection and Configuration How to connect the appliance is described in the Hardware Quick Start Guide For configuration you can follow the initial setup wizard described in the WebAdmin Quick Start Guide or cancel it and perform a manual setup see the Sophos UTM Administration Guide Serial Console You can connect a serial console to the COM port of the Sophos UTM hardware appliances You can use for instance the Hyperterminal terminal program which is included with most versions of Microsoft Windows to log on to the appliance console Use the provided RJ45 to DBY adapter cable to connect the console to your hardware appliance The required connection settings are Bits per second 38 400 Data bits 8 Parity N none Stop bits 1 Access via the serial console is activated by default on ttySI The connections of the appliances and the respective functionality are listed in chapter Operating Elements and Connections Australia amp New Zealand S
8. ot function correctly Off The adapter is sending or receiving network Yellow Flashing data The frequency of the flashes varies with the amount of traffic Activity LED Off No activity UTM 220 Operating Instructions UTM 220 Operating Instructions e x LCD and Control Keys The Sophos UTM 220 has an LCD and an operating unit with four membrane keys In the LCD 16 characters per line can be displayed The display contains in three cycling views information on the hardware and specific system states After the security appliance has booted this message is displayed Sophos UTM version CPU type and RAM size CPU load bar OS load bar Uptime Network load bar With the membrane keys three actions can be executed gt Factory reset All settings are reset to the factory settings The factory reset function sets all of the configuration settings and options to their original state All data entered after the initial installation will be deleted including the HT TP proxy cache the entire email queue accounting and reporting data passwords and uninstalled Up2Date packages The version of the software will not change That is all firmware and pattern updates that have been installed will be retained gt Reboot machine The security appliance is rebooted The reboot action will shut down the system completely and reboot Vv Shut down The security appliance is shut down The shut
9. rm your settings The shut down action will now start Putting into Operation Caution Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Scope of Supply The supplied parts are indicated in the Hardware Quick Start Guide UTM 220 Operating Instructions Mounting Instructions The UTM 220 appliance is designed for use in racks Please consider the following security tips Important Note The appliance is designed for use in rack systems Functional reliability outside of a rack cannot be guaranteed Warnings and Precautions The appliance can be operated safely if you observe the following notes and the notes on the appliance itself Rack Precautions Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them In single rack installation stabilizers should be attached to the rack gt In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rack to become unstable General Server Precautions Review the electrical and general safety precautions that came with the components you are adding to your appliance Determine the placement of each component in the rack before

Download Pdf Manuals

image

Related Search

Related Contents

Philips Forecast Cambridge  COM Express Type 6 Lite Carrier Manual  Samsung 74V Bruksanvisning  Elévateur de bain gonflable  E-Vino 取扱説明書ダウンロード  FinePix S6500fd Bedienungsanleitung  Samsung L110 Uživatelská přiručka  CISPR14-1 第 5.1 版 翻訳版  CAHIER DES CHARGES Four Mixte 10 nx  Quick Start Guide Simple Motion Module LD77MH  