        Installation manual Envalve
         Contents
1.    s function is the regulation of a flow of fluid media through a pipe or in case of the double  Envalve version the mixing of two flows of fluid media with a certain proportion to each other     It is prohibited to use the Envalve otherwise than fully connected and installed in a suitable piping system  with a maximum working pressure of 6 bar  The difference between the pressure before and after the  Envalve must be below 6 bar    The Envalve is therefore classified as an unfinished machine     Installation manual Envalve series VK  VKF and PVK  Page 4 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    1 1 2  Specifications                         Type VK   Power 3 5 W   Voltage 24 of 230 Vac   Capacity 10   100 m3  hour valve   Pressure max  6 bar   NW 20   63   Drive Electromotor Centra Honeywell VMM or VMK       Table 1  Specifications VK series                                Type VKF   Power 9   26 W   Voltage 24 of 230 Vac   Capacity 280   2000 m3  hour  valve   Pressure max  6 bar   NW 75   200   Drive Electromotor Hora M135  M150 or M180       Table 2  Specifications VKF series                          Type PVK   Power 5 9W   Voltage 24 Vdc   Vac or 230 Vac   Capacity 56   2000 m3  hour valve   Pressure max  6 bar   NW 20   63 and 75   200  different connection to  piping  see paragraph 2 2    Drive Pneumatic actuator OMAL series DA    Dual drive in combination with electrical  monostable valve type 5 2          Operating pressure      
2.    see  also paragraph 4 1     The Envalve can not be used in an explosive environment     1 8 Warranty   The warranty is 6 months from commissioning  with a maximum term of 2 years after production   Commissioning is the installation of an Envalve in an installation    Parts must be brought to the producer when warranty is claimed     Warranty expires with one or more of the following terms   e unprofessional use and or installation   repeatedly ignoring advice from producer and or supplier   reparation  maintenance or use by incompetent or unauthorised persons   use of incorrect electrical or fluid connections   use of the machine in an unsuited environment   intended damaging or modification of the machine     All these and further warranty terms are in conformation with the METAALUNIEVOORWAARDEN  edition  January 2008      1 9 CE sign    The CE sign concerns the conformity of the Envalve with the machine  low voltage  EMC and PED directive   Because it is an unfinished machine  the Envalve cannot comply with all the essential safety precautions  a  list of these can be supplied by the producer     The CE sign is located on the sticker on the base plate   According to the low voltage directive  the Envalve is classified as a Class I machine     1 10 Rest risks    For practical and economic reasons it is impossible to fully cover all the risks for 100   besides  the risk of  a machine is tightly correlated with the functionality of the installation as a whole  These so call
3.  17 of 23    Van der Ende Pompen B V     Maasambacht 4  2676CW Maasdijk  Nederland  Annexes  e   Electric schematics    e Declaration of conformity of components    Installation manual Envalve series VK  VKF and PVK    Page 18 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    Electric schematics    VK series          Picture 6  electric scheme VK series     Terminal 1 is the ground cable  when terminal 1 and 2 are connected to a power source  the valve will turn  clockwise  when terminal 1 and 3 are connected to a power source  the valve will anticlockwise     The earth cable must be connected to the terminal on the housing  marked with the earth sign     Installation manual Envalve series VK  VKF and PVK  Page 19 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    VKE series       Picture 7  electric scheme VKF series     Terminal N1 is the ground cable  the control current runs through terminal 2 and or 3  The earth cable  must be connected to the terminal marked with the earth sign     Installation manual Envalve series VK  VKF and PVK  Page 20 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    PVK series    I     l              I  1     l       TT ee mmm wn vm wm mmm mm mm mz ST    A             L                   Picture 8  electric scheme control valve PVK    The flat plug  marked with a small earth sign  is the earth connection  by running a current from  connection 1 to 2  a ste
4.  6 bar       Table 3  Specifications PVK series     Installation manual Envalve series VK  VKF and PVK    Page 5 of 23          Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    1 2 Schematic picture of the machine  In this picture  the parts and components are numbered        Picture 1  Schematic picture of an Envalve     Note  the Envalve in the picture is a VKF  although other versions are not entirely the same  the main  components and the functions of the components is the same     Installation manual Envalve series VK  VKF and DNK  Page 6 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland       Name       Drive       Position indicator          manual   auto    control button       Base plate       Coupling       Housing       Paddle       Secondary butterfly valve       Collar       Flange       Primary butterfly valve  direct driven        Seal       3 lie   S lee   alo lato ole    Connector shaft                n Coupling rod       Table 4  Names of the main components     1 3 Operation and manual control    It is possible to operate the Envalve remotely  but it is also possible to operate the Envalve manually  that  is to say  it is possible to manually open or close     turn     the Envalve  The procedure for this differences  between the different versions     Important  when the valve is switched from manual to automatic operation  the valve should be  half open  exactly between open and closed      Make sure the a
5.  and fix the power supply     Find the cause and replace the fuse     Check the connections  schematic is in the  annexes      Find the cause  try to dry the drive  replace  the seal of the drive when needed and  consider a heating element  see paragraph  EJA    Find the cause and replace the drive motor    check the supply voltage and functioning of  the valves  especially check for obstructions  of the paddle         2  Drive turns  instable restless   constant opening  and closing     Incorrect connected capacitor or loose  contact    To much voltage drop due to long cables or  insufficient diameter  Fluctuating power supply    Drive is told to open   nd close at the same  time    Contact the producer     Check the supply voltage  at the drive    calculate voltage drop  replace power cable  when needed     Check the supply voltage     Change the control program        3  Drive fails  regularly    Loose contact in power supply    Bad or defect limit switches    First  make sure the power is switched off   Check and tighten all contacts     Replace limit switches          4  Drive doesn   t turn   entirely  to the end  position       Incorrect set limit switches    Defect sprocket in drive    Drive capacitor defect    Too much system pressure or to much  pressure difference over the valve    Obstruction of the paddle       Let the producer reset the limit switches  do  not attempt to do this yourself  warranty will  expire     Replace the drive  this is often an error due  t
6.  damage the seal  The valve can be installed in every position  except up side  down  drive under valve      a DA IS    correct correct wrong    Picture 5  Installation positions Envalve     Installation manual Envalve series VK  VKF and PVK  Page 12 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    When the valve is positioned correctly between the collars the flanges can be shoved over the collars and  secured with the metal bolts and nuts  NW75 and larger  or the nut can be tightened  NW63 and smaller      After installation the connection must be checked  try to operate the valves manually by closing and    opening them by hand  This must be able without scraping noise and with only moderate force  See  paragraph 1 3 for instructions on manual operating     Do not tighten the bolts and nuts too much  this will deform the seal and possibly block the paddle     Installation manual Envalve series VK  VKF and PVK  Page 13 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    4 2 Electric    The valves must be electrically connected by professional and competent persons  look at the pictures in  the annexes for help     VK series   Remove the three screws from the lid of the drive    remove the lid of the drive    put the power cable trough the cable gland    connect the earth cable to the terminal marked with the earth sign  only the 230 V version    connect the ground cable to terminal 1    connect the two phases to t
7.  use can be found in  paragraph 1 5 and 1 7     It is forbidden to use the Envalve in a system with solid substances or gasses     Only connect the Envalve to pressurised air and or electricity if its fully installed in a suitable system   Before the Envalve can be taken out of the system  the pressurised air and or electricity must be  disconnected     Maximum pressure for the Envalve is 6 bar     Always disconnect the pressurised air and or electricity before maintenance or reparation  Disconnect the  electricity by using the main switch from the controlling organ  control panel or something alike   this  switch must be locked during the work on the Envalve    Always fully connect the pressurised air and electricity after the maintenance or repairs and test the  Envalve     Work on the Envalve or the connection of the electrics or pneumatics must be done by a competent and  professional person     230 V Connections must be 4 core cables  open  close  ground and earth  of sufficient diameter and  quality  conform regulations     Always connect the ground cable to the terminal marked with the ground sign     Make sure the power cable is connected to a group fused at maximum 16 A with a ground fault circuit  interrupter of 30 mA     Installation manual Envalve series VK  VKF and PVK  Page 11 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    4  Installation    4 1 Mechanical    For the correct installation of the Envalve  first fit all the piping 
8. Installation manual    Envalve    Series VK  VKF and PVK       Version 2 1  20th of October 2011    AE  VAN DER ENDE         POMPEN    w    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    Preface    This installation manual is a manual for the installer or technician who is installing the Envalve  It is not a  manual for the  end  user of the Envalve     If not entirely installed and connected  the Envalve has no real function and is therefore classified as a  machine which cannot function independently  or    unfinished machine     later on this is called just     machine         This installation manual contains only prescriptions concerning the safe installation  correct connecting  and safe working with the Envalve  It is not a manual for the entire installation in which the Envalve is  installed  The installer should take care of that manual     Every chapter has a number and chapters are divided into paragraphs where needed   The list of contents  on page 2 gives an overview of the chapters and paragraphs with a reference to the page numbers     When a number or letter is between brackets this refers to the numbers or letters of parts in  picture 1     Installation manual Envalve series VK  VKF and PVK  Page 2 of 23    Van der Ende Pompen B V     Maasambacht 4  2676CW Maasdijk  Nederland   List of contents  Pr a Cia 2  List OF COMES rt A A AR A AAA A A 3  I ee cdta dias dara 4  1 1 General information iioeiaeueiiai aa iaai a aie rr 4  1 1 1 Descr
9. and or pneumatic connections can be made    With an Envalve  a flow of fluid media can be precisely controlled or stopped  Application examples are  the  continuous  mixing of two flows of fluid  VK an VKF series  double version  and the remote shutting  of pipes  all series      The remote operation of the Envalve is possible because the drive is powered by electrics or pneumatics   Normally there are two limit switches installed  but more position switches or a potentiometer can be  installed to    read     or read more precisely  the position of the Envalve  The position indicator  b  indicates  the position of the paddle  In case of a double version of the Envalve  the position indicator indicates the  position of the paddle of the valve directly under the drive     The    turning time    of the valve  the time in which the valve goes from fully closed to fully open  varies per  series  the VK and VKF take about 70 seconds  10 seconds is also available  ask the producer for  information   for the PVK this time depends on operating pressure and the pneumatic connections   Optional is a flow regulator on the PVK  with this the turning time can be tuned     The VKF and VK series are bistable  which means that when the power supply is cut off  the valve stays in  that position  The PVK series is monostable  the valve returns to its default position when the power  supply is interrupted  only if there is sufficient air pressure   Other configurations are available     The conn
10. ctives   and sole responsibility of    Company  rR uren GmbH  amp  Co  KG    Application of the following standards       DIN EN 292 1 and DIN EN 292 2 Safety of machinery     DIN EN 60204 1 Safety of machinery     Electrical equipment of machines   e DIN EN 61000 4 2   3   4   5   6   11 Electromagnetic compatibility  EMC      Testing and measurement  techniques  Immunity tests      DIN EN 55011 Industrial  scientific and medical  ISM  radio frequency equipment     Radio disturbance  characteristics     Limits and methods of measurement    e DIN EN 55022 Information technology equipment     Radio disturbance characteristics   Limit and methods  of measurement e      DIN EN 50082 1   2 Electromagnetic compatibility  EMC      Generic standards  Immunity for residential   commercial and light industrial environments and for industrial environments    A Technical Documention is completely available     The operating instructions for the appliance are available     e In original version  German language      in English language    Schlo   Holte Stukenbrock  10 12 2008___ IA Holter Regelarmaturen GmbH  amp  Co KG  Place  Date Signature Specifics concerning the signatory    Installation manual Envalve series VK  VKF and PVK  Page 23 of 23    
11. ection between the Envalve and the piping for NW63 and smaller consists of a collar and a pvc  nut  At NW 75 and larger this connection consists of a collar  two flanges and some nuts and bolts     For NW63 and smaller the Envalve has a seal made of EPDM  default  or FPM  optional  between the  paddle and the housing  And 2 O ring seals between the valve and the collars    From NW75 and larger the Envalve has only one seal  which sits between the housing and paddle and  between the valve and the collars     2 3 Transport and storage    Transport and storage do not require special packaging but can not be stacked without special crates or  other precautions  The Envalve and the drive in particular is only moderately resistant to water and  moist  so the Envalve must be protected against both  see also paragraph 1 7      Installation manual Envalve series VK  VKF and PVK  Page 10 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    3  Safety instructions    Read and understand this installation manual and take all the prescribed precautions before installing or  connecting the Envalve     The Envalve may only be used for the applications the Envalve was designed for     The Envalve was designed to function as a stop or regulator in a system or process working with flows of  fluid media  These media may only contain those chemicals suitable for the Envalve and its components  which come into contact with them  Further information about application and
12. ed above  or for purposes where  failing of the Envalve can cause serious danger for persons     1 6 Media    The Envalve is not chemically resistant for all chemicals  ask the producer of the Envalve for advise  If the  Envalve is used for wrong chemicals  leaking will occur and warranty will expire     It is possible to alter the seals in the Envalve in order to make it  more  resistant for other chemicals  ask  the producer of the Envalve for advice     1 7 Use environment    The Envalve is meant for use as a controlled stop or regulator of a flow of fluid media  The Envalve may  only be used if it is fully installed and connected in accordance with the installation prescriptions     For use in a moist and or cold environment  the Envalve can be equipped with a small heating element for  protection  see picture below   Ask the producer for advice     85 1735 1 S  61 003 00 RD ES       Picture 2  Heating element  optional      The Envalve and particularly the drive may not be submerged     Installation manual Envalve series VK  VKF and DNK  Page 8 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    Install the Envalve only if there is enough free space around it  a person must be able to operate the button     man   auto     c  safely  It must be impossible for a person to get stuck between the base plate and  connector shaft or other objects     The Envalve can be installed in virtually every position  except up side down  drive under the valve
13. ed rest  risks are listed in the table below  It is important that the user is aware that  even while we have taken all  possible safety precautions  the use of the Envalve involves certain risks  Follow the prescriptions in this  manual in order to minimize these risks           Risk  Rest risk description Risk  Category  Nr  factor   1  Moving part approaches static object  3 All    When the connector shaft moves to left or to right it  approaches the base plate              2y When the Envalve is used while it is not fully installed and 3 Al l  connected  there is a danger of fingers getting stuck   3  Risk on fire  if the electrics are not professionally connected  4 Al 3    a risk on short circuit and fire arises                    Table 5  List of rest risks        1  The aim is to reduce every risk to a level below 4  but this isn   t always possible due to the functionality of  the machine     Installation manual Envalve series VK  VKF and PVK  Page 9 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    2  Description    In this chapter the machine is described  it is the background information needed to work safely with the  machine     2 1 Working principle    The Envalve regulates the flow by means of turning a paddle in a housing  By turning the paddle  the  effective diameter of the pipe changes     2 2 In general    The Envalve must be installed in a suitable piping system  only after installation is completely finished the  electric 
14. ering current   the control valve will open and the Envalve will open  The control  valve is monostable  so the control valve will close automatically  and the Envalve will return to its default  position  when the steering current is removed     Connect the pressurised air supply to connection 3  connections 4 are the supply lines for the actuator and  5 are the silencers  The Envalve is sold with connections 4 connected  ready for use   The turning time can  be adjusted by placing a flow regulator on connections 5  Contact the producer for help and advice     The needed air pressure for a correct functioning of the actuator differences between the various types  and sizes  Usually  this is minimum 6 bar and maximum 8 bar     Number 6 in this picture is the control screw for manual operation of the control valve  The control valve  will open by turning the control screw a quarter  see also paragraph 1 3     Installation manual Envalve series VK  VKF and DNK  Page 21 of 23    Van der Ende Pompen B V        Maasambacht 4  2676CW Maasdijk  Nederland  Declaration of conformity of components  Honeywell  KONFORMITATSERKLARUNG        DECLARATION OF CONFORMITY  DECLARATION DE CONFORMITE    Name   Name   Nom  Honeywell GmbH   Anschrift   Address   Adresse  Boblinger Str  17  71101 Sch  naich  Germany    Wir erklaren in alleiniger Verantwortung  dass  We declare on our own responsibility that  Nous d  clarons sous notre propre responsabilit   que    das Produkt   the Product   le Prod
15. erminal 2 and 3    tighten the cable gland    check the functioning of the Envalve    switch the two phases if the drive turns the wrong way round   close the lid of the drive en secure with the three screws     VKF series   Remove the four screws from the lid of the drive    remove the lid of the drive    put the power cable trough the cable gland    connect the earth cable to the terminal marked with the earth sign  only the 230 V version    connect the ground cable to terminal N1    connect the two phases to terminal 2 and 3    tighten the cable gland    check the functioning of the Envalve   switch the two phases if the drive turns the wrong way round   close the lid of the drive en secure with the four screws     PVKseries   Remove the screw on top of the cap of the  electric  control valve  the black part     remove the cap of the coil of the control valve    put the power cable trough the cable gland    connect the earth cable to the terminal marked with the earth sign  only the 230 V version    connect the wires to terminal 1 and 2    tighten the cable gland    place the seal between the coil and the cap    put the cap back on the coil and tighten the screw    check the functioning of the Envalve     4 3 Pneumatic    PVK series   e See picture 8 in the annexes    e connect the air supply to connection 3   e make sure the connection is correct     Installation manual Envalve series VK  VKF and PVK  Page 14 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasd
16. ijk  Nederland    5  Commissioning  Check whether the valve is installed correctly and the flanges or nut are secured  Check before filling the    system with fluid again the functioning  manual and automatic      When the Envalve is set from manual to automatic  remote  operation  push against the connector shaft  until a    click    is heard     It is important that the valve is in the neutral position  in the middle between open and closed  before  going from manual to automatic operation and or before commissioning  This prevents the valve turning  beyond its limit switches and getting damaged  See also paragraph 1 3     6  Maintenance  The Envalve is designed as maintenance free  when used in a suitable environment for intended    applications  Periodic inspection and cleaning are not essential but desirable     Clean the Envalve with a dry cloth  do not use water on the electrical part  Do not use aggressive cleaning  chemicals     Installation manual Envalve series VK  VKF and PVK  Page 15 of 23    7  Errors    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland       Problem    Cause    Solution       1  Valve does not turn    Control button    man   auto    is set to manual    No power supply present     Blown fuse    Faulty connected drive    Short circuit due to moist    Burned drive    Put the valve in the neutral position  Set the  control button to    auto    and push against the  connector shaft until a    click    is heard     Find the problem
17. iption of the machine    4  DAL PEA a EE 5  1 2 Schematic picture of the machine    ANE scene cree eee arar 6  1 3 Operation and manual Control sa asasinada a e nnnnnnnnn rn narra H  L   USCIS Seed denten EE  EE  EN a SEN noes 8  1 5  Application nv A A EE  a a a ENN 8  1 6 Media ri A ada 8  1 7 Use environment AA A a a cans 8  1 8 Warranty msi A een EE EE a a KEREN EEN 9  L  Ckaten  ue O een EE EE  cr A NEEN 9  III A corannonannorennoobdanoganacanaroconnondinonanhs a A 9  2  Description e EE EE eae 10  2 1 Working prrerglct ees unenee NN o arca ida cas dare a 10  DT AAA ci A EE ANEREN NEN NEEN NEEN KREE NNN ENNER 10  2 3 Transpo C OU Storage EN gene BEE lc a RER ES Sen  10  3  Safety  EES RES urena reniir A EE a oa EENEN ANAE NEE KEAR NN ENER EE ENNEN 11  rl A com o o ae babes te baa ide ba Ed RE ENG d  er 12  4 1 Mechanical icon a  MA EE  i 12  pE E e E E o A o E O E O O 14  APN EE 14  Klee 15  6  ManU  15  E E E a O OO yore EAT 16  8  DeclarationloR coni orii yaranana dd E EE A AE Ea so 17  ANNERES E A A ANE E e E te 18  Electric chona ii 19  Declaration of conformity of COMPONENES          cc ccc eee eee ee ene cnn rrnn nn eee enna nr rnnnarnranannss 22    Installation manual Envalve series VK  VKF and PVK  Page 3 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    1  Identification    In this chapter some general information about the machine is listed  The purpose of this chapter is to  state the boundaries of the machine  the global functio
18. ning and possible applications of the machine     1 1 General information    1 1 1 Description of the machine    The Envalve is available in different versions  the VK with max  NW63  the VKF from NW75 up to NW200  and the PVK from NW20 up to NW200  All Envalve   s are electrical or pneumatic powered butterfly valves     An Envalve consists of five main parts   1  Motor plate  metal base plate  d  single or double version   2  Butterfly valve  1 or 2 butterfly valves with EPDM or FPM seal  f  g and possible h    a  Later on  this is referred to as    valve    or    actual valve      3  Drive  electromotor or pneumatic actuator  a    4  Connector  between the motor and the butterfly valve and in case of a double Envalve version also  between both butterfly valves  e and n    5  Connection between the piping and the valve s   i and j  by means of a collar or nut     The purpose and function of the Envalve is the regulation or stopping of a flow of fluid media through a  pipe  The Envalve can be operated remotely     The valve has an outgoing axle with which the valve can be rotated  By means of fixing a remote operated  drive on this axle  the valve can be operated remotely    In case of the double Envalve version  two interconnected valves with one drive   the valve with the drive  on top is in the position indicated with the indicator  b  while the other valve is exactly 90 degrees rotated  from this position  This is default  other configurations are possible     The Envalve
19. o obstruction of the paddle      Contact the producer     Check and reset the system pressure     Disassemble the valve  loosen the  flanges nut and remove valve from system   and remove obstruction        Table 6  Errors and solutions     Installation manual Envalve series VK  VKF and PVK    Page 16 of 23       Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    8  Declaration of conformity    EG DECLARATION OF CONFORMITY   according to Annex II B of the Machinery Directive 2006 42 EG  for machinery  which cannot function independently or machinery parts     We  Van der Ende Pompen B V  Maasambacht 4  2676 CW Maasdijk  Nederland    Herewith declare  on our own responsibility  that the product     Envalve  Series VK  VKF and PVK    Which this declaration refers to  to be incorporated into machinery or assembled with other machinery to  constitute machinery covered by the Machinery Directive  is  where appropriate  in conformity with the  following standard s  or other specifications     Machinery Directive 2006 42 EG  Low Voltage Directive 2006 95 EG  EMC Directive 2004 108 EG  PED Directive 97 23 EG    The product this declaration refers to must not be put into service until the machinery into which it is to  be incorporated has been declared in conformity with the provisions of the relevant European Directives     Nederland P J  van der Ende  Maasdijk ES   5 November 2009 Le y   Ge   es  ln    A    Installation manual Envalve series VK  VKF and PVK  Page
20. order to be able to  electrically     read    the position of the valve  The limit switches are  sealed for warranty purposes     For the remote operation paragraph 4 2 and the annexes can be consulted  in which an electric scheme of  the Envalve can be found  Further connection  to a control panel or something alike  is not included in this  installation manual     Installation manual Envalve series VK  VKF and PVK  Page 7 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    1 4 Users    In general  there are no direct    users    of the Envalve  because it is operated remotely by a control panel or  other  semi automatic controller  Allowed users are at least 18 years and employed at the company at  which the Envalve is installed  and who are designated to be competent and able to operate the Envalve     Not allowed users are users who don   t comply with above description  Not allowed users are all users who  cause danger and or unsafe situations for themselves and or others while using the Envalve     1 5 Application    The Envalve is meant for the regulation or stopping of a flow of fluid media through a pipe or  in case of  the double version  the mixing of two flows with a certain proportion to each other  It is forbidden to use  the Envalve while it is not fully installed and connected in accordance with the installation prescriptions in  a suitable piping system     It is forbidden to use the Envalve for purposes other than that as describ
21. uit     Rotary Valve Actuator    VMK8 4 VMM20 VMM20 24 VMM40F  VMK10 4 VMM30 VMM30 24 VMM40 24F  VMK10 4 24 VMM40 VMM40 24    allen Anforderungen der Richtlinien 2006 95 EG   2004 108 EG entspricht   meets all requirements of the directive 2006 95 EC   2004 108 EC   remplit toutes les exigences de la directive 2006 95 CE   2004 108 CE     Angewandte Normen  EN 60730 1 A15 2007  Applied standards  EN 60730 2 14 A1 2001    Normes appliqu  es   gd Ae  A    Dr  Thomas Arenz  General Manager    Sch  naich  12  M  rz 2008    Installation manual Envalve series VK  VKF and PVK  Page 22 of 23    Van der Ende Pompen B V   Maasambacht 4   2676CW Maasdijk  Nederland    HORA    Excellence Is our standard    EU Declaration of conformity    Confirm with the   e Directive 98 37 EC  Appendix Il A  of the European Parliament and of the Council of  22 June 1998 on the approximation of the laws of the Member States relating to machinery     Council Directive 2004 108 EC  of 20 January 2005 on the approximation of the laws of the  Member States relating to electromagnetic compatibility     Council Directive 2006 95 EC  of 16 January 2007 on the harmonization of the laws of the  Member States relating to electrical equipment designed for use within certain voltage limits       low voltage   The appliance  Product   turn actuator  of construction r Regela  Type  M106  M125  M135  M140  M150  M180  230 V     has been developed  designed and manufactured in accordance with the mentioned European Dire
22. utomatic operating of the Envalve is disabled before any manual operating is tried     e VK  press the black knob on the upper side of the drive  as long as this knob is pressed  the Envalve  can be controlled manually using the connector shaft  m     e VKF  turn the red knob on the side  c  to the    man     manual  position  the Envalve can now be  controlled manually using the connector shaft  m   To reset the valve to automatic  remote   operation  turn the red knob  c  to the    auto    position  then push against the connector shaft  m  until  a    click    is heard    e PVK  there are two options for the PVK  The first and most desirable option is to use a flat screwdriver  to turn the control screw  nr  6 in picture 8  a quarter  this is only possible if the pneumatics are  connected  The other option is to use a spanner to turn the axle on the upper side of the actuator   drive   this is only possible if the pneumatics are disconnected  no air pressure on the control valve    For this last option  also the pneumatic pressure lines between the control valve and the actuator  should be disconnected  Make sure the air pressure is not re connected when these lines are  disconnected        The position indicator  b  indicates the position of the paddle     Every Envalve is equipped with two limit switches  these switches stop the valve when it   s in the most  open or most closed position  There is a possibility to use these switches or to incorporate a  potentiometer in 
23. without glue  When everything is correct  in size and properly aligned  loosen the bolts or the nut and take the actual valve from between the collars   Be careful not to damage the seal while doing this  Put the valve aside and remove the collars from the    piping     Glue the collars to the piping  Excess glue on the inside of the piping should be removed  this glue can get  between the seal and the paddle and cause serious damage or leaking     Make sure you put the flanges or the nut over the piping behind the collars before the collars are  glued  the flanges or nut cannot be added later     From NW75 and larger there is only one seal  serving as seal between the paddle and housing and as seal  between the collars and actual valve  NW63 and smaller have two separate O rings as seal between collar  and valve and another seal between the housing and the paddle  It is important that for all the Envalve   s  plain smooth collars are used  not the ones with a groove  for an O ring   otherwise they will leak  The use  of additional seals is unnecessary and we strongly advise not to     Collar Flange Bolt  Cross section Nut Cross section Collar H  VK m  VKF  amp  PVK     ah    _  Manche   seal  Paddl  e  SS REES Paddle                          O ring       my  P     Picture 4  Seal Envalve NW63 and smaller  left  and NW75 and larger  right    When the collars are glued and excess glue is removed  the actual valve can be put back between the    collars  again  be careful not to
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Descargue el Manual!  Wipe Technology White Paper  KIDdesigns DF-M63  Dual MXD105 Car Stereo System User Manual  NST 4.0 User Manual  Sick S300 Mini Manual - Allied Automation, Inc.  1-4 CAE Example  シャッターコントローラ SSH-C2B 取扱説明書 Ver. 1.0  Pipette Calibration System Student User Manual    Copyright © All rights reserved. 