1. 2 6 0 2 6 13 Linux kernel 2 6 14 2 6 22 Please check the latest driver released for your Operating System in the User Section at www procentec com profitap Register your personal data to access the download area Registering is free and keeps you informed of product updates Version 1 1 21 August 2009 Page 3 12 Industrial ProfiTap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A 2 2 2 1 5 Setup the TAP Network Card After the installation ProfiTap presents itself as a virtual Network Interface Card NIC to your Operating System and to any Analyzer The below settings are for internal communication only there is no external effect nor are these settings presented or exposed to the monitored link In any case we recommend setting an IP address The installed TAP driver as under paragraph 2 1 4 is represented as a Network Interface Card NIC to your Operating System Notes Configure the IP Protocol Stack IP address 192 168 0 1 Submask 255 0 0 0 Note Gateway or DNS settings must be undefined Profilap is now ready to use as source for your installed Analyzer Analyzer Setup To perform analysis you can use either any of the supported Analyzers or the powerful Wireshark Analyzer provided on the USB key 2 2 1 Selecting ProfiTap as source for your Analyzer Start your preferred Analyzer and select the new virtu
2. button in the upper left Eee eee corner of the User SetUp window indicates that p Sorrel contin PROCENTEC IP address 169 254 74 192 ProfiTap is properly installed and connected Se T Permanent setup Overview As shown there are four configurable X Enable CRC Error filter Tuad a 7 5 configure ProfiTAP parameters options settings available P Enable CRC32 Remover enable disable the TimeStamp feature CRC error filter _ Enable TimeStamp enable disable the Filters setup a discard extract Filter CRC32 remover Enable Filter Seana apts Wart Timestamp enable disable Ethernet MAC Destination address XXIXXIXXIXXIXXIXX MAC IPv4 address amp protocol filter Ethernet MAC Source address XXIXXIXXIXX XK XK Ethernet Type KXXX L CRC error filter checked and enabled by default aS ee j e ma aan You may decide to keep packets corrupted by a Pesara Adre r y oy oY ji Note The indicated MAC amp IP Adress CRC error Deselect the checkbox Enable CRC soya pestination Address i a a ae COS aes error filter to include those packets upstream to ee i S EREE the Analyzer during your analysis Discard Filter Buttons Checkboxes 1 CRC32 remover checked and enabled by default eer seine Wireshark expects the last PROFINET byte to settings can be stored for permanent or be a Trans Status byte which should always be send Cont f O0hex If the CRC32 bytes are ad
3. strict liability or other legal or equitable theory for any loss of use of the product inconvenience or damages of any character whether direct special incidental or consequential including but not limited to damages for loss of goodwill loss of revenue or profit work stoppage or malfunction Copyright This publication including all photographs and illustrations is protected under international copyright laws with all rights reserved Neither this manual nor any of the material contained herein may be reproduced without written consent of the author Trademarks The trademarks mentioned in this manual are the sole property of their owners Version 1 1 21 August 2009 Page 9 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A Version 1 1 21 August 2009 Page 10 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A Version 1 1 21 August 2009 Page 11 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A Version 1 1 21 August 2009 Page 12 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved
4. User Manual for the Industrial ProfiTap English Order code 513 00011A PROGCENTECG User Manual English Industrial Profilap Ethernet PROFINET Protocol Analyzer Model C1AP 100 TF PROCENTEC Turfschipper 41 2292 JC WATERINGEN The Netherlands Tel 31 0 174 671800 USB 2 0 Fax 31 0 174 671801 Email info procentec com Multi platform Web www procentec com Version 1 1 21 August 2009 Page 1 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A 1 Introduction ProfiTap Industrial is an interface to utilize monitoring of a PROFINET network It is an essential tool for PROFINET engineering activities especially to verify the connections and performance of IRT and other real time applications The monitor port of switches is unreliable for monitoring it can be occupied or is not forwarding all traffic The load on the Ethernet port of the laptop is also too high with IRT applications because 2 channels are merged in one The ProfiTap has a USB link with the laptop that streams the captured messages to the accompanying driver which emulates an additional Ethernet port on the laptop and hands the messages over to any application The ProfiTap also prevents the laptop to send out messages on its own initiative which could jeopardize the real time behaviour and security of the network Profilap cuts down the
5. al device showing up at the select NIC window Refer to your Analyzer s manual or the User Help about how to select a Network Interface Card 2 2 2 Using alternative Wireshark Ethereal As an option you may install an alternate Analyzer i e the one provided on the USB key or from any other source Notes Always follow the specific instructions as indicated by the installation manual wizard of the chosen Analyzer In addition perform step 2 2 1 to enable ProfiTap to be the selected resource for Analysis Verify the listing on our website regarding supported Analyzers at the User Section of www procentec com profitap Make sure to use the latest available version if any problem occurs with ProfiTap For the latest version refer to www procentec com profitap Version 1 1 21 August 2009 Page 4 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A 3 ProfiTap User Setup model C1AP 100 TF The User SetUp is used at Model T and TF to enable or disable features or setting up filters for individual use Depending on the demands for analysis you may intend to exclude some unimportant data or any unwanted frames You may need to reduce the monitored traffic for your Analyzer or even exclude other devices for your current environment With the provided filter capabilities ProfiTap will work in a customized setting for te
6. ble Checkbox Permanent Setup Checking Permanent Setup will store the configuration in non volatile memory and is restored after power off Without selecting this checkbox your settings are cleared when you disconnect the ProfiTap Additional features Clear config by clicking on this button the actual configuration of ProfiTap will be cleared back to default Check factory options by clicking this button the CRC LEDs of ProfiTap will illuminate to indicate which options are implemented Right LED illuminating indicates whether filter setup corresponding software Profilap User SetUp is available or not Left LED illuminating indicates whether timestamp corresponding software NanoSec Converter is available or not Version 1 1 21 August 2009 Page 6 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A 4 NanoSec Converter model C1AP 100 T and TF For Packet Capture with via ProfiTAP the TAP can be set to add a 5 nanosecond resolution time information to each packet see chapter 3 2 Note To take advantage of this nanosecond timestamp it is mandatory to perform the initial packet capture with ProfiTAP in combination with Wireshark By default the Converter will read a recorded captured file and interpret this additional precise timing information to create a new capture file with a Nanos
7. de by defining the way the Ethernet MAC Destination address MONK OK filter should work creating an excluding or including filter see below Ethernet Type XNXX You may combine all filter options to one filter i e Ethertype plus one MAC Address plus IP Range About Ethernet MAC area Replace XX XX with a full or a partial hexadecimal MAC address in order to either select one specific or a range of source and or destination addresses Note You need to enter a pair number of bytes e g 45 F0 01 XX XX XX In case of a wrong entry the related field will be indicate in red About IPv4 area IPv4 Protocol YX Enter one or a part of a source and or a destination decimal IPv4 address you want to keep or discard You may also configure to filter to a certain protocol Leave the field s empty you don t want to specify IPv4 Destination Address IPv4 Source Address To finalize your filter select whether you want the address or protocol you entered to be used for discard or keep keep Filter ProfiTap will only pass the traffic matching your filter settings up to your Analyzer discard Filter has the opposite effect Profilap will surpress all traffic matching your settings and pass all other traffic up to the Analyzer Initializing the Filter to ProfiTap Before sending the settings to Profilap pressing Send config button make your decision to use this filter to be permanently or temporarily availa
8. ded the last oe Permanent Setup set function to be byte is not OOhex and the frame is considered aerate te to be invalid This option allows the TAP to truncate this information from your frames Please keep in mind that since ProfiTap natively keeps packets containing Figure 3 User SetUp window CRC errors all of the erroneous packets will be treated as valid packets Version 1 1 21 August 2009 Page 5 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A L Timestamp enable disable unchecked and disabled by default Profilap adds a timestamp field to each packet seen on the monitored link see chapter 4 Note By default this option is disabled This results in a traditional recording of packets during capture without 5nS time information appendix O MAC IPv4 address amp protocol filter unchecked and disabled by default Due to its nature a standard TAP is transparent and forwards all packets seen without any restrictions upstream to your Analyzer Setting up this Filter allows you to control the monitored dataflow upstream to your Analyzer by a range of MAC IPv4 addresses and or protocol type to keep or to discard General l l l Ethernet MAC Source address KK XX KX XK KX XX The filters are straight solutions There is only one Filter active at a time The most important decision has to be ma
9. econd resolution timing transferred to the standard position in each packet The new file will be stored again as a pcap file Depending on your Analyzer you may also use this new file on other Analysis equipment 4 1 Installation Locate the folder named Profilap Software on the USB key Copy the file NanoSec Converter jar to your hard disk You may create a shortcut on your desktop to have the Converter in one click available Note The software is a Java based application Make sure you have installed JAVA on your computer first otherwise install Java Runtime available from www java com Profitap INDUSTRIAL PROCENTEC NanoSec Converter vii 4 2 How to use NanoSec Converter Description This ProfiTAP Application is designed to convert the Time Stamps of a microsecond based peap file This file must have been prior captured by ProfiTAP with the Time Stamp Option During a Packet Capture Save Wireshark Analyzer creates After Conversion the tracefile indicates a precise nanosecond based Time Stamp as has been stored by the hardware of ProfiTAP during capture one or more pcap files Usage a Drag n drop the file to be converted into this window here to start the conversion b A new file will be created with a prefix of nsscoce pcap stored in the currenty selected directory Locate the folder of the captu re files and execute the c open the new file ns coox pcap as normal and find the timestamp in
10. equipment needed for Network Analysis even reducing the points of failure during Analysis Only a laptop desktop and one Profilap is needed The power is supplied by your monitoring equipment via USB2 0 connection No extra adaptor is required In this manual you will find everything you need about how to install and use the product and its provided software Industrial ProfiTap visual description 1 Port A RJ45 connected to the network 2 Port B RJ45 connected to the network 3 Two green LEDs to indicate a CRC error 4 Two green LEDs to indicate the activity on the network 5 Green LED to give information about power supply status LED illuminated device powered 6 USB2 0 connector linked to your monitoring device i e a laptop computer Figure 1 Identification of connections and LEDs Version 1 1 21 August 2009 Page 2 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A 2 Installation instructions 2 1 Hardware amp driver installation 2 1 1 Insert the USB key for accessing copying the contents to an installation folder It is recommended to copy the contents to your hard disk first if there is no empty USB2 0 port available After copying you may disconnect the USB key and proceed Otherwise use the USB key for installation procedure and decide to connect the ProfiTap to a second USB2 0 port and rem
11. mporary or permanent usage Profilaps filter mechanism works almost like a pure hardware filter using this feature will result in a better performance during packet capture and helps to keep an eye on the important things 3 1 Installation Install WinPcap 3 1 or higher on your computer either by downloading it on www winpcap org or by installing Wireshark Locate the folder named ProfiTap User SetUp on the USB key As a registered customer you may check for latest available versions at our website www procentec com profitap Copy the files User SetUp jar and jnetopcap dll to the same directory on your hard disk If you are running a Windows based OS you can copy jnetocap dll to c windows system32 instead You may create a shortcut on your desktop to have the ProfiTap User SetUp in one click available Notes The software is a Java based application Make sure you have installed JAVA on your computer first otherwise install Java Runtime available from www java com Furthermore in some systems the jar extension is associated to a different program e g Winrar or Nokia s Cellphone applications In this case the applications will be opened with the associated program instead of being executed Occasionally an undefined error may occur Correct this by deassociating the JAVA extension in your configuration setting 3 2 Usage Profilap INDUSTRIAL PROCENTEC User SetUp v3 4 1 Run the program a green
12. nano second resolution at each NanoSec Converter O Drop pcap files here iis once converted file may be converted again to be accessable by any other vendors fileformat using the regular save as function within you Analyzer The file s to be converted can be dragged and dropped into the window of the Converter tool see This Converter Too filters outan unwanted packages occasionally partially or frequently being sent Figure 4 and will be automatically processed To identify the converted file s in this folder each new file s will carry a prefix ns pcap Figure 4 NanoSec Converter window During conversion follow the instructions as displayed in the application window Note The native capture file s will not be changed After conversion open the ns pcap file s with Wireshark You will find the precise timing information at its normal position Note Wireshark is able to store files in other than pcap formats to make it available for other Analyzers First refer to the manuals of these Analyzers to set up Nanosecond time resolution Version 1 1 21 August 2009 Page 7 12 Industrial ProfiTap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A Technical Data Industrial ProfiTap Analyzer Dimensions and weight Dimensions L x W x H mm 102 x 55 x 24 mm Weight Approximately 125 g Ambient conditions Operating
13. ove USB key when finished 2 1 2 Connect ProfiTap to the network using Category 5 FTP or STP Foiled or Shielded Twisted Pair cables as shown in Figure 2 UTP Unshielded Twisted Pair cable is not recommended in industrial environments USB cable to PC laptop Network Port A to DCE by straight Cable to DTE by cross over cable Network Port B to DTE by straight Cable to DCE by cross over cable The maximum distance between any of the connected devices is 90 meters FTP cable to industrial network PROFINET cable to industrial network Figure 2 cable connections 2 1 3 Connect the USB port Connect the USB port to a PC MAC USB2 0 port and the Power LED will illuminate The cable length should not exceed 5 meters When you plug in the USB cable both CRC LEDs should illuminate for approximately one second to show your Profi Tap factory configuration Right CRC LED illuminating indicates that filter setup is available but not necessarily enabled Left CRC LED illuminating indicates that timestamp is available but not necessarily enabled 2 1 4 Install the driver Install the driver according to your Operating System The current available drivers are located on the USB key at the driver section or within your installation directory on your hard disk Supported O S are Windows ME 98 CE 5 0 Windows XP 2000 Vista 32 bit Windows XP 2003 Vista 64 bit MAC OS X 32 bit 64 bit x86 PowerPC Linux kernel
14. temperature 0 to 50 Celsius Storage temperature 40 to 120 Celsius Isolation class IP 20 DIN 40 050 Relative Humidity 10 to 95 no condensing Protocol specifications Supported Protocols t b d Power supply specifications Nominal supply voltage 5 Vdc from USB 2 0 port Current consumption 300 mA at 5 Vdc Compliancy FCC class A Version 1 1 21 August 2009 Page 8 12 Industrial Profi Tap Manual1 EN docx PROCENTEC 2009 Copyright all rights reserved User Manual for the Industrial ProfiTap English Order code 513 00011A Disclaimer The information in this document is subject to change without notice The manufacturer makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose The manufacturer reserves the right to revise this publication and to make changes in the content hereof without obligation of the manufacturer to notify any person of such revision or changes Warranty and Liability PROCENTEC warrants that this product is free from defects in material and workmanship at time of shipment The warranty period is three years from the date of purchase PROCENTEC assumes no liability for products that have been subjected to abuse modification misuse or if the model or serial number has been altered tampered with defaced or removed PROCENTEC is not liable under any contract negligence