Home
INSTALLATION MANUAL - fintotoegangsbeheer.nl
Contents
1. eere 20 C 80 C Shaft travelling tiMe scsncasansuisnseiesicasueitentsarsenstsnacnnessueninbsantoteonen 21 sec aor E TORTE Fadini A15 by Agip ang 280 mm Piston CIAMETIC cccccceescescssesesecsesseseeesseseesesecsesseeessesessesessesatees 45 mm Shaft diametre sese entente nnnes 16 mm Pushing power ODED assumit QR ERU ROQKEn br POSEEN MERI EEIITS 2720 N Pulling power l0S8 icsicsisstr nr perte ria m a SR re Pisani ze 3 120 N Weight of NUPI 66 complete eessseesss 0 Kg PrOtecHOTtHSERTIOAL US aceto tt mE Cerat Cu Pid UNE ones IP 553 Overall dimensions LxWXxH 1 240x86x86 mm ELECTRIC MOTOR Power Output 0 18 KW 0 25 HP Supply VOltdl Becas rand pP EU EE RERUM Ger unanuia sansanonin aaite 230 V ARI QD MR T 50 Hz Absorbed PUTTOTIEsseincenirpaquaKb iini eats ani 1 2 A Absorbed powe umana ERU Tm Rua IERI 250 W Capa 0 M E e ene er 12 5 uF Motor rotation speed e seca nu PI rait MIN TUR EO HIERRO NOE CIS 1 350 rpm Intermittent Service uu ccceesecssesssecsessesesscsessesecsuseeseseesesaesessusesenseses S3 Flexible electric cable CEI 20 52 FROR 450 750 V BO E Gate height and width mm H 1200 W 17600 Static weight per gate leaf 70 100 Kg SERVICE ooo Duty Cycle carie 19 sec Opening 30 sec Stop 21 sec
2. 00 gt OIL HYDRAULIC ACTUATOR FOR DOUBLE SWINGING GATES FADING the gate opener Made in Italy MUPI 66 FITTING INSTRUCTIONS NUPI 66 is an oil hydraulic actuator locking in the closed gate position to operate gates that are not wider than 2 0 m Fixing to the gate and gate posts is by specially designed brackets Peculiar with this operator is the absence of the high low pressure valves power Is set and controlled by the electronic control box ELPRO 7 RP See the description on page 4 Elpro 7 RP wiring diagram RELEASE RELEASE RELEASE KEY DEVICE FLAP COVER oO B ee a ea ee COVER WITH CAP END COVER fa FIXING PIN RR FRONT FIXING HEXAGONAL HEAD PIN w lt t BENZING RING 12 5 uF CAPACITOR e Me b REAR PLATE me WITH HOLES A FOR FIXING 4 ADJUSTMENT S i REAR BRACKET CABLE TERMINALS RELEASE VALVE CYLINDER PISTON BLOCK FASTENER BLOCK HEAD SHAFT PIC 1 FITTING NUPI 66 This explains how to remove the operator cover and fix the actuator The first operation Is to unlock the operator push the lock flap to one side insert the key and turn it 90 clockwise The locking barrel can be tilted open and the operator is now released pic 2 Unscrew the two screws that fix the operator cover and remove It Unscrew the screw that fixes the rear end cover and remove it The actuator is so ready for fixing operations e Special fittin
3. 0 aso D o8 oo eo c o o lt CD peo xew fid 1 10 A vc LEARNING TIMES BY REMOTE CONTROL AUTOMATIC SEMI AUTOMATIC OPERATING MODES STEP BY STEP MODE INTERMIDIATE STOP bwa No 4053 PARTIAL PEDESTRIAN OPENING DIP SWITCH SETTING PIC 10 Q 12345678 1 2 3 4 5 Ol PROGRAMMING P AOE dINV19NIHSVT13 2A 24V low AlddflS YAMOd JSVHd 319NIS ZHOS AVES c voltage fuse Elpro 7 RP is an electronic control panel developed for Nupi 66 The main feature of this unit is the capability to learn the required working times during operation gate delay in open and close cycles dwell time It is recommended to carry out the installation in strict compliance with the rules of good technique and fit the system with ground stops in the Open and Closed positions Elpro 7RP is to be powered with 230 V single phase voltage It is manufactured in conformity to 93 68 EC Low Voltage Safety Norms and EMC 93 68 EC Norms for the Electro Magnetic Compatibility Installation is to be carried out by qualified technicians in compliance with the existing safety regulations The manufacturer is not liable for incorrect use of the equipment and reserves the right to do changes to the unit and this manual any time Elpro RP DESCRIPTION OF FUNCTIONS OF THE CONTROL PANEL FOR SWINGING GATES ELECTRICAL CONNECTIONS The control panel must be installed in a sheltered dry place inside the box provided with it Fit
4. Closing Time of one complete cycle esses 70s No of complete cycles Opening Stop Closing 51 h No of cycles a year 8 hours service a day 150000 EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF THE STANDARDS 98 37 EC e DECLARATION OF CONFORMITY e GENERAL WARNINGS e EN 12453 EN 12445 STANDARDS e CEI EN 60204 1 STANDARDS e WARRANTY CERTIFICATE ON THE CUSTOMER S REQUEST FADING hd meccanica FADING AUTOMATIC GATE MANUFACTURERS MUPI 66 OIL HYDRAULIC ACTUATOR WARNINGS Before installing the equipment carry out a Risk Analysis and fit any required device in compliance with EN 12445 and EN 12453 Safety Norms tis recommended to keep to the instructions here outlined check the specifications on the motor sticker with your mains supply Dispose properly of the packaging cardboard nylon polystyrene through specialized companies Should the operator be removed do not cut the electric cables These must be properly removed from the terminal board in the junction box Switch off the mains switch before removing the junction box cover where the electric cables are terminated All the system must be earthed by using the yellow green wire tis recommended to read the regulations suggestions and remarks quoted in the booklet Safety norms CHECKING AND MAINTENANCE To achieve an opti
5. Pulse to close starts M2 motor M2 gate starts closing N The time between the 8 and 9 operations is stored by the system as Gate Delay Time on Closing Cycle Qt Operation A pulse to close starts M1 motor M1 gate starts closing 10t Operation A pulse stops M2 motor M2 gate on closed gate position In order to ensure that the gate is securely held in stop position it is advised to pulse the actuator ie gate to stop approx 3 4 seconds after the gate has reached the end of the permitted stroke on the closed gate stop position 11 Operation i A pulse stops M1 motor M1 gate on closed gate position In order to ensure that the gate is securely held in stop position it is advised to pulse the actuator ie gate to stop approx 3 4 seconds after the gate has reached the end of the permitted stroke on the closed gate stop position The 11t operation concludes the procedure for the control panel to learn the required working times After the learning procedure it is possible to set the operating modes either ON OFF as required by means the Dip switches on the PCB NUPI 66 TECHNICAL SPECIFICATIONS 17240 PIC 12 OIL HYDRAULIC ACTUATOR Pump flow rate oe svaipcsnceraacsntadecbinasttecauetionsmyatnceumneinusseenssa 1 4 7 min Working PFO S SUN sae idati ce iint iid nicks tni iun 2 MPa 20 Bars Working temperature
6. limits were pre set Beyond these values the automation will start with the maximum pre set time M1 and M2 Motor Run time max 55s Dwell time on Automatic Mode maximum 90s 2 During the learning operation no other functions can be activated the Photocells and the Stop button are out of service 3 If the new setting operation is interrupted for example mains cut off the times in the previous setting are memorized 4 Normally not on programming mode the P button has the same function as a remote control button and itis possible to test the system by pulsing it the Led 7 becomes a simple indicator the same as the indicator to terminal 8 Led Status Indication Dip Switch DIP SWITCH E 1 ON Photocells Stop during opening ON Ee ae ee supply Alignt 2 ON Radio no reversing during Opening al a al al L2 Photocells if obstructed light goes off 3 ON Automatic Closing ESTEET OFF L3 0pen Alight whenever an Open pulse is given 4 ON Pre flashing in service L4 Close Alight whenever a Close pulse is given 5 ON Radio step by step L5 Stop It goes off on pulsing Stop 6 ON No delay on opening L6 Radio It goes on by pressing a transmitter button 7 ON Additional pushing on the gate leaf after closing L7 Gate Status and programming led 8 ON Pedestrian opening by Open button 24V 3W Indicator Pedestrian Opening M1 Motor by Open pulse E Partial opening for pedestrians is only allowed in closed P ol cs M gate position by pul
7. the lateral terminals pic 9 on page 4 in parallel with the capacitor Put back the cable fastener On connecting the electronic control panel Elpro 7 RP it is advised to set the torque control switch to position 3 pic 10 on page 5 and pic 11 on page 6 ELECTRICAL WIRING DIAGRAM The diagram here below shows the electrical connections of all the accessories that are available for the system IMPORTANT All the system must be properly earthed 1 PHOTOCELL RECEIVER TRIFO 11 10 FLASHING LAMP MIRI 4 2 JUNCTION BOX 11 PLUG IN RADIO RECEIVER CARD ASTRO 43 2 R 3 POST WITH PHOTOCELL PROJECTOR TRIFO 11 12 ELECTRONIC CONTROL PANEL ELPRO 7 RP 4 OIL HYDRAULIC ACTUATORS NUPI 66 13 AERIAL BIRIO A8 5 CLOSED GATE STOP REQUIRED 14 0 03A MAGNETIC THERMAL CIRCUIT BREAKER 6 RADIO TRANSMITTER ASTRO 43 2 TR SMALL BEYOND 100m 2 5mm CABLE TO BE USED 7 POST WITH PHOTOCELL RECEIVER TRIFO 11 15 OPEN GATE STOP REQUIRED 8 PHOTOCELL PROJECTOR TRIFO 11 9 KEYSWITCH PRIT 19 PIC 7 N W CARRY OUT A RISK ANALYSIS IN COMPLIANCE WITH EN 12445 AND EN 12453 NORMS AND FIT ANY SAFETY DEVICE WHERE REQUIRED 12 5 uF CAPACITOR TERMINALS FITTED ON TO THE NEUTRAL BLUE WIRE THE OPERATOR BRACKET BLOCK TO BE CONNECTED TO THE CENTRAL TERMINAL LIVE 1 NEUTRAL BLUE THE TWO LIVE WIRES TO BE LIVE 2 CONNECTED TO THE o LATERAL TERMINALS PARALLEL TO THE CAPACITOR NOTE BY EXCHANGING THE POSITION OF
8. L1 WITH L2 THE ELECTRIC MOTOR IS SUPPLY CABLE REVERSED 230V 50 Hz FLEXIBLE FLAME PROOF NPI PIC 8 450 750 4x1 5 mm gt rit O CEI STANDARD 20 52 IT IS IMPORTANT TO AVOID ANY SHARP BENDS WITH THE CABLE IT MUST DANGLE IN A WIDE LOOP ER WIRING DIAGRAM CONTROL PANEL ELPRO 7 RP IMPORTANT Elpro 7 RP is specifically designed to suit NUPI 66 only The manufacturers decline any responsibility for damages caused by incorrect use or applications with accessories that are not FADINI For the electrical connections to the motor of NUPI 66 mains and flashing lamp use 1 5 mm cables For the photo cells keyswitches and other accessories you can use 1 mm wires Make sure that all the electrical connections are done in compliance with this diagram Once the terminals 19 20 are supplied with 230V 50Hz power the neutral and live properly connected the red led No 1 L1 illuminates to confirm that the board has voltage Read the instructions contained in the ELPRO 7 RP box Elpro RP ELECTRONIC CONTROL PANEL FOR NUPI 66 WITH PROGRAMMABLE RADIO TECHNOLOGY PLUG IN RADIO CARD SUPPORT DIP SWITCH TRANSFORMER carat Elpro 7 RP lt gt BUTTON ELECTRONIC TORQUE CONTROL LI 2 L3 L4 L5 L6 e o E e JN STI390 0Hd 3301214129313 CO SINGLE PHASE SINGLE MOTOR M1 PHASE actuator and MOTOR M2 electric lock if required 1H9Il1AS31Hn029 OQO YO4 AV 138 OV Acl YO N Z Z O O
9. g LOCKED GATE GATE POST 150x150 WY There can be cases where special fitting requirements are i ZY needed to meet gate hinges on the post edge line brickwork A B L of i to be indented special opening NUPI 66 is supplied complete En Un sone with an adjustable rear fixing plate a pattern of fixing holes x GATE MOVEMENT CENTRES makes the rear fixing extremely versatile to suit any gate Refer n to the diagram on the right for fixing geometry pic 3 SS T s CLOSED ELECTRIC LOCK An electric lock is recommended in installations where each gate leaf exceeds 1 8 meters and is subjected to high winds or are close boarded gates GATE S iH C co a Ns c Sng S CLOSED GATE 1210 if 1 SST L 3 3704130 SS pu PIC 3 IMPORTANT It is important to temporarily fix the operator rear casting using the center hole in the fixing plate and once the installation is completed move the rear fixing to the inner hole IMPORTANT it is necessary to firmly fix the gate stops to the ground in the open and closed gate positions See pic 5 on page 3 and pic 7 on page 4 parts 5 and 15 before installing the operator A reinforcement plate is recommended for the rear fixing either to be embedded in the gate post anchoring plates to be welded to improve holding or bolted to it so that the operator rear fixing can be welded to it in full respect of the geometry indicated below See distance
10. he 24V Low Voltage Fuse back into its holder 3rd Operation When the Led L7 illuminates release button P Led L7 will flash 9 times and the flashing lamp will illuminate the program learning working times has been entered ie learning the required operating times by the P button or by remote control The last option allows the installation agent to have direct visual control of the operation being performed by the gates IMPORTANT at this stage two options are allowed to go on with setting L7 O O 4th Operation A pulse to open starts M1 motor the first gate starts opening Gate Delay Time in Open Cycle with the options in service Dip No 6 0N The time passing from 4th to 5th operations is stored by the system as the or out of service Dip No 6 OFF the time is stored but no delay will occur 5th Operation A pulse to open starts M2 motor second gate starts opening 6th Operation A pulse stops M1 motor first gate wide open on open gate stop Drwg No 4153 7t Operation A pulse stops M2 motor second gate wide open on open gate stop The time passing from 7th to 8th operation is stored by the system as Dwell Time in service on AUTOMATIC MODE Dip No 3 ON or out of service Dip No 3 OFF dwell time still in the system memory but not applicable 8 Operation A
11. mum performance and longer life of the equipment and in observance of the safety regulations it Is recommended that inspections and proper maintenance are made by qualified technicians to the whole installation le both the mechanical and electronic parts as well as wiring Mechanical parts maintenance every 6 months approx Electronic apparatus and safety equipment maintenance inspection monthly The growth of MECCANICA FADINI has always been based on the development of guaranteed products thanks to our TOTAL QUALITY CONTROL system which ensures constant quality standards updated knowledge of the European standards and compliance with their requirements in view of an ever increasing process of improvement The CE mark certifies that the operator conforms to the essential requirements of the European Directive art 10 EEC 73 23 in relation to the manufacturer s declaration for the supplied items in compliance with the body of the regulations ISO 9000 UNI EN 29000 Automation in conformity to EN 12453 EN 12445 safety standard Distributors box The manufacturers reserve the rightto change the products without any previous notice Via Mantova 177 A 37053 Cerea Verona Italy Tel 39 0442 330422 r a Fax 39 0442 331054 e mail info fadini net www fadini net
12. s A and B in pic 5 distances are strictly referred to the center lines of the gate hinge and operator rear fixing A 130 Ground stop in closed gate position Temporary installation axis to coincide with center hole Closed gate nan final installation axis to coincide with inner hole B 130 Pierced fixing plate 7 ly e I i j m f OX N R ti ear casting z lcd Pi Ground stop in ii open gate EN E position E T i E PIC 5 lt Reinforcement plate PIC 4 By means of a spirit level make sure that the fixing plates are perfectly levelled respect distance D for the front fixing the gate in closed position ie operator shaft driven 260 mm out B 130 A 130 Spirit level Never weld the front fixing bracket directly to the gate Use a reinforcement plate Remove the operator before welding M This distance to allow 1cm clearance between the cover and the gate in open position PIC 6 lt D 80 Atthis stage NUPI 66 is fixed to the gate leaf Note that it is locking when the release lid is closed with the lid in the open position the locking device is overridden and the gate can be pushed open by hand pic 2 on page 2 The electrical connections of the power supply cable to the terminal board are the next step Remove the cable fastener Connect the neutral to the central terminal and the two live wires to
13. sing to Open the gate closes after the A De Mp dwell time if set to Automatic Dip Switch 3 ON Cy Fast Flash closing movement 8 _ the first pulse operates 1 gate leaf M1 alow Hash a movement the second pulse operates the second gate leaf ON 1 gate leaf for pedestrian opening OFF Standard operation IMPORTANT The Elpro 7 RP control panel is supplied with open close time memory MORE POWER TORQUE CONTROL SETTING Adjust torque from lower level step 1 up ELECTRONIC to the required amount of power step by step to achieve a correct TORQUE performance of the system so that the gates are operated as required CONTROL and any injuring hazard is prevented Please note torque is to be adjusted by a technician LESS POWER PIC 11 TORQUE ADJUSTING WHEN LIGHT GATES ARE INVOLVED made of timbers PVC or aluminium etc replace the existing capacitor with a 8 uF one and adjust torque accordingly starting from step one lowest setting Elpro RP DESCRIPTION OF FUNCTIONS OF THE CONTROL PANEL FOR SWINGING GATES Preliminary notes to Learning Mode Make sure that the gate is closed Make sure that the gate stops in the respective open and closed gate positions are firmly fixed to the ground 15 Operation Cut off power supply to Elpro 7 RP by removing the 2A 24V Low Voltage white Fuse which is on the right upper side of the PCB 2nd Operation Hold the button P pressed and re power the PCB by inserting t
14. the mains to the control panel with a 0 03A high performance circuit breaker Use 1 5mm section wires for voltage supply electric motor and flashing lamp Maximum recommended distance 50m Use 1mm section wires for limit switches photocells push buttons key switch and accessories Bridge terminals 1 and 2 if no photocells are required Bridge terminals 3 and 6 if no key or push button switches are required N W To fit extra accessories such as lights CCTV etc use only solid state relays to prevent damages to the microprocessor WORKING LOGIC Elpro 7 RP is supplied with pre set working times so that to allow the first installation Working time is about 20 s Gate Delay Times Opening 2s Closing 6 s Dwell on automatic Mode 15 s Once satisfied that the system is working all right new working times can be programmed to meet the user s needs or the installation requirements Elpro 7RP functions can be set by Dip switches both before and after the times have been stored by the unit LEARNING THE TIMES ELPRO 7 RP learning operation is quite easy and can be achieved either by the P button on the PCB or by the remote control after entering setting mode see point 1 Starting the unit to learn the required times with the gate in closed position pulse the equipment to one complete cycle ie open stop dwell close Important 1 In order to avoid setting times which are not suitable with the correct gate functioning some time