Home
        User's Manual - Opticon-SHOP
         Contents
1.           Article Code Article Code  TERMINAL PHL1300 CRADLE IRU1300  Ci PHL 1300 A73900R0020 Ci IRU 1300 A74030N0020  ADDITIONAL EQUIPMENT ADDITIONAL EQUIPMENT  Battery pack for terminal OD Power supply A50200N0020     Rechargeable battery D Cable RS232 DB9F 02520000020  pack LBP 1300 ORBLIOP0020 Ci AT adapter 09M 25F P10AT000040  D Cable RS485 02520000050       Software development tools      Microtec   ANSI C cross compiler 08010000010  C C library for   Opticon terminals D4030000020  C Application Generator   Potstar  Limited version D6010000010  Ci Application Generator   Potstar  Professional version D6020000010    23    OPTICON  Opticon Article Code  00220000130    24    
2.   6 1 4 Functionality 18  23 HANDLING PRECAUTIONS 9 6 1 5 Environmental specifications 19  6 1 6 Physical specifications 19  2 4 ASSEMBLY 10  2 4 1 Terminal 10 6 2 SPECIFICATION CRADLE 19  2 4 2 Cradle 10 6 2 1 Electrical specifications 19  2 4 3 Terminal on cradle 10 6 2 2 Functionality 19  6 2 3 Environmental specifications 19  2 5 INSTALLING  REPLACING AND CHARGING 6 2 4 Physical specifications 19  BATTERIES 11  2 5 1 Required batteries 12 7 TROUBLESHOOTING 20  2 5 2 How to charge the rechargeable  battery pack in the cradle  12 7 1 COMMUNICATION PROBLEMS 21  2 5 3 When to replace or recharge the Ce READ OPERATION PROBLEMS 21  main battery  12 13 TERMINAL PROBLEMS 22  2 5 4 When to replace the backup  battery  12 8 PRODUCT ORDERING  2 5 5 How to  re place the main battery INFORMATION 23  in the terminal  12  2 5 6 How to  re place the backup battery  in the terminal  13  2 6 INSTALLING IN A SYSTEM 14  2 6 1 Single cradle 14  2 6 2 Cradle network 14  2 6 3 Dip switch settings on cradle 15  3 OPERATION OF THE TERMINAL 15  4 SCANNING 16  4 1 How to read the barcode 16  4 2 Barcode reading problems 16    USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE       1 INTRODUCTION    This terminal is a pocket sized  programmable  handheld terminal  and is well suited for a  variety of portable applications  It has a built in  laser scanner that can scan all popular bar  code labels at varying distances     User s applications can be downloaded to the  terminal to adapt the terminal t
3.  USER   S MANUAL PHL 1300 TERMINAL   IRU1300 CRADLE    IRU1300     Cradle       ADDITIONAL  IRU1300     Power Supply       RS232 cable DB9 F    rT    RS485 network cable    USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE    22 DETAILED VIEW 2 2 1 Dimensions of terminal  132 mm    55 mm          USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE    2 2 2 Details of terminal     1     Reading window  laser beam for barcode reading will be  emitted from here    LCD Display  for displaying information    Full        Off  Sufficient battery power  On  Battery low  Replace immediately     La  Alpha mode on  Shift key activated   Backlight of LCD Display   When the backlight is turned on  the power  consumption increases  To extend the life  time of your batteries use the backlight as  little as possible     LED indicator  can be used to indicate results  for example  bar code reading   status of communication    Buzzer  auditive indicator    Power key  for switching power On Off    Trigger key  definable by application  typical use  read key  switches laser beam  on for barcode reading    Quick keys  definable by application  typical use  menu scroll keys or yes no  input    Control keys  definable by application  for controlling basic functions  typical use as below     CLR   Cancel input  BS   Back space  S   Shift key       S   on the LCD display indicates  the terminal is in the shift mode    10     11     12     13     14     15     Character keys O definable by application  
4.  dipswitch           7 RS M TERMINATED    sw 1   off  sw 2   on  sw 3   on    2 6 3 DIP switch settings on cradle    Setting the DIP switches on or off will result in  differrent baudrates and enabled or disabled  functions of the cradle     TY Open the cover of the DIP switches on the  bottom of the cradle in order to reach the  DIP switches    C  Turn the DIP switch ON by moving it  upwards into the direction of the dipswitch  number    I  Turn the DIP switch OFF by moving it  downwards into the direction OFF     SWITCH   FUNCTIONS DEFAULT         SW 1 RS 232 inuse   not ON  CONNECTION in use  SW 2 RS485 inuse   not OFF  TERMINATOR in use  OFF  OFF  OFF  N       SW 3 RS485 inuse   not  TERMINATOR in use    SW6   BAUDRATE   E    n   BAUDRATE          USER   S MANUAL PHL 1300 TERMINAL   IRU1300 CRADLE    OPERATION OF  THE TERMINAL    The functionality of the terminal is determined  by software  the so called user application   that is running on the terminal     Usually  the terminal is not equipped with  software and has no functionality  At first the  user application must be loaded before the  terminal can be used for barcode scanning     Tools for developing a user application on the   PC for use on the terminal  as supplied by   Opticon are    I  Application Generator   PotStar  Limited or Professional    CI C language  Microtec ANSI C compiler  and C library for handheld terminals        The user application must be downloaded  from the PC into the terminal  You can use
5.  the  cradle or an infrared adapter for communication  between the terminal and the PC  A program  on the PC will send the user application to the  terminal  where it is stored in FlashROM  memory     When the functionality of the terminal is defined  by the application it is ready for operation     In a typical application you will press the trigger  key and scan a bar code label as described in  the next chapter  Scanned data and data  entered from the keyboard is stored in the  terminal s RAM  The user application can use  this data in subsequent steps     The collected data can be transmitted to the PC  for further processing through the cradle     15    USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE       4 SCANNING     gt  Please take care of the handling  precautions     O Please make sure that the terminal is  installed according to the installation  instructions     1 Never remove the main battery pack  while the terminal is turned on   Doing so can cause data in the terminal  to be deleted or corrupted     4 1 How to read the barcode    The scanning sequence is defined by the  user   s application  A typical sequence is     Ci Press the  PW  key to turn power on    C Check the display for the message   READ BAR CODE      Point the terminal to the barcode and  press the Trigger key    UD  Point the laserbeam to barcode as shown    in the scan position illustration   I  The barcode will be read and the reading  results will be indicated     A    Good Read    means 
6. 00 CRADLE    TROUBLE  SHOOTING       This chapter contains information on solving  problems you may encounter when using the  terminal and or cradle  If problems occur  first  carry out some general checks  before  verifying the problem with the descriptions in  this chapter     General checks    C Make sure everything is installed properly   IT  Check the power supply of all devices   D Is the reading window of the terminal clean    TT Is the optical window of the cradle clean    I  Are the bar code labels readable  eg  not  damaged or poorly printed     If the equipment still does not work after these  checks have been performed  please verify if  one of the problems described in this chapter  applies to the problem you have with the  scanner     It is possible that you may not solve the  problems  despite our descriptions  In this  instance  please contact your dealer or  Opticon     When the terminal needs to be repaired   please ensure that the label with the serial  number is still present  If sending the terminal  or cradle  please use the original packing to  minimise the chances of damage     20    USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE       7 1 COMMUNICATION    7 2 READ OPERATION       PROBLEMS    No communication from the cradle to the  device  or data is transmitted distorted or  corrupted        Power indicator of the cradle is not green         Check if the battery case cover of the  PHL1300 is closed properly    ID  Clean the optical interface windo
7. 45    Depth of field    Resolution    70   380 mm   at PCS 0 9  res  1 0 mm     6 1 3 Supported symbologies  Chinese Post 20f5  Codabar incl  ABC and CX  Code 39  Code 93  Code 128  EAN 8 incl   2  5  EAN 13 incl   2  5  IATA  Industrial 20f5    Interleaved 20f5  Italian Pharmaceutical  Laetus  Matrix 20f5  MSI Plessey  UK Plessey  S Code  Telepen  UPC A incl   2  5  UPC E incl   2  5    6 1 4 Functionality    Memory    ROM  32 kB  C FlashROM  O S and program   2 x 256 kB  total 512 kB   Ci fast RAM  2 kB     RAM  data storage    8 MB battery backed up D RAM    16 bit    Quartz RTC  time and date  programmable  leap year handling        Microprocessor    Real time clock    Charging method Recharging Lithium lon pack in  terminal via cradle    18    Display     accuracy   60 sec  month     M 96x64 Pixels   graphic LCD with backlight  UM Character fonts    5 10 lines x 16 characters       USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE       Keyboard I  19 keys total   18 keys user definable   C Alpha Numeric mode    Functionality is provided by user  application  The application may  be downloaded from PC via  cradle        Programming    Interfaces    RS232 supported by cradle  T IrDAsupported on terminal     RS485 supported by cradle    Baudrate  2400   115200 bps       Transmission speed    6 1 5 Environmental specifications       Temperature     10    40   C in operation      20    60   C in storage   Humidity F 20   80   in operation    non condensing      20   90   in 
8. NAL   IRU1300 CRADLE    7 3 TERMINAL PROBLEMS    Terminal does not respond to key presses   while the display stays on      gt  Message    Application halted    or     No application installed    is shown    Ci There is no user s application for PHL1300  loaded in the terminal  Contact your  supplier     O For example pressing the shift key does  not toggle the shift indicator    I  There is a flaw in the application program   Disconnect the battery pack  and place it  then back in    The terminal will be in off state   Activate the system menu and restart the  application  or download new application    C If problems appears continously contact  the supplier of the user s application     Laser stays off  when pressing the  triggerkey     D Power is off     L The triggerkey is no powerkey  Press the    powerkey to get power    C  If the terminal is not used the scanner will  switch off all functions   Press the powerkey to reactivate     D Laser temperature has become too high    Ci The laser is switched off automatically   when thelaser temperature becomes  above 50  C  Wait until the temperature  has dropped     22    Terminal gets no power  when pressing the  powerkey     2 The main battery is exhausted        Replace the battery pack  or charge the  terminal in the cradle     Terminal does still not operate and needs a  service   Send the terminal to your supplier for service   paying attention to the limited warranty     USER   S MANUAL PHL 1300 TERMINAL   IRU1300 CRADLE
9. User   s Manual    Pocket Terminal PHL1300  Cradle IRU1300    USER   S MANUAL PHL 1300 TERMINAL   IRU1300 CRADLE    CAUTION  This user s manual may be revised or  withdrawn at any time without prior notice     Copyright 2002  Opticon Sensors Europe B V   All rights reserved     This manual may not  in whole or in part  be copied   photocopied  reproduced  translated or converted to  any electronic or machine readable form without  prior written consent of Opticon Sensors Europe     Limited warranty and disclaimers   By opening the package of this product you agree to  become bound by the liability and warranty  conditions as described below     Under all circumstances this manual should be read  attentively  before installing and or using the product   In no event  Opticon Sensors Europe will be liable for  any direct  indirect  consequential or incidental  damages arising out of use or inability to use both  the hardware and software  even if Opticon has been  informed about the possibility of such damages     A serial number appears on all Opticon products   This official registration number is strictly related to  the device purchased  Make sure that the serial  number appearing on your Opticon device has not  been removed  Servicing by our Repair Department  can only be carried out under warranty     All Opticon products are warranted for the legal  warranty period after purchase  covering defects in  material and workmanship  Opticon will repair or   at its opinion  repl
10. ace products that prove to be  defective in material or workmanship under proper  use during the warranty period     Opticon will not be liable in case modifications are  made by the customer  In such case the standard  repair charge will be applicable  The standard charge  for repair will also be applicable in case no defect is  found at all  These rules also apply for products that  are still under warranty  Therefore  you are advised to  have the product specifications always at hand        The general use and functioning of the  terminal together with the cradle will be  described in this manual    The exact behavior of the terminal  depends on the user application that is  running  For instructions about applications  please consult the documentation of  that software     Trademarks used are property of their respective  owners    Please read this manual carefully  before using the terminal  to maximise  the efficiency of this terminal              PHL1300 ver1   printed 04 2002    USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE    CONTENTS    page page  1 INTRODUCTION 4 5 PIN OUT 17  2 INSTALLATION 5 5 1 RS232 cable for cradle 17  5 2 RS485 cable for cradle network 17  2 1 UNPACKING 5  6 SPECIFICATIONS 18  2 2 DETAILED VIEW 6  2 2 1 Dimensions of terminal 6 6 1 SPECIFICATIONS TERMINAL 18  2 2 2 Details of terminal 7 6 1 1 Electrical specifications 18  2 2 3 Dimensions of cradle 8 6 1 2 Optical specifications 18  2 2 4 Details of cradle 8 6 1 3 Supported symbologies 18
11. e  conditions    C  Avoid a place under strong light   Otherwise IrDA communication may be  disturbed        Power Connection    C  Attach the DC jack of the AC adapter  into the socket of the cradle   Then connect the AC adapter to the  mains outlet   TL  When the terminal PHL1300 with the  rechargeable battery pack is placed in  the cradle  the LED on the cradle turns  green    CI When the terminal PHL1300 with  penlite batteries is placed in the cradle  no  indication is given by the cradle     2 4 3  Terminal on cradle    Take notice that the IRU1300 cradle is designed  for the PHL1300 terminal  No other types of  terminals can be placed into this cradle        Wrong use of batteries might cause  serious damage  to the terminal or to the cradle     In order to avoid damage  it is very important to take notice  of the instructions     D Insert full batteries before use of the  terminal     1 Never remove the main battery pack  while the terminal is turned on   Doing so can cause data in the terminal  to be deleted     O Never change the main battery pack  while the backup battery is out   Doing so can crash the application     en you do not use the terminal for  a long time  make sure the main  battery has enough capacity   When there is not enough capacity in the  main battery the backup battery can not  be charged and will become too low     USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE    2 5 INSTALLING  REPLACING  AND CHARGING BATTERIES    oni use recommended batte
12. i  Lithium  button type      2 5 2 How to charge the rechargeable  battery pack in the cradle     Make sure that the Opticon rechargeable  battery pack is inserted in the terminal    If the terminal with the battery pack is placed  in the cradle  the LED on the cradle will turn  green    When the terminal is placed in the cradle  the  rechargeable battery pack will be charged  automatically for 8 hours     2 5 3 When to replace or recharge the  main battery     There are 2 reasons for replacing the main  battery   C  as soon as possible after the battery    CI when you are not using the terminal for an  extended period     2 5 4 When to replace the backup battery     When low battery mark    Mu appears   replace the battery without delay     12    2 5 5 How to  re place the main battery  in the terminal        on use batteries as specified in  paragraph 2 5 1     Di you have data stored  make sure the  backup battery is placed and full  enough  to avoid data loss     Unlock main battery case cover   ref  1    TZ Unlock the case cover by use of a flat  screwdriver or a coin    TJ Remove old battery by simply taking out        Installing Opticon battery pack   ref  2   C  Follow the instructions on the label     Installing penlite batteries   ref  3   I  Make sure you use the right battery size     D Place 2 batteries in the battery holder  aligning plus     and minus     ends as  shown inside the battery compartment        Lock main battery case cover   C  Position the case co
13. ld  humid  moistured or  dusty     Do not expose the product to  rain or water splash     DN  N  N  xx  SS    Do not subject the the product  to very strong impact  do not  throw or drop the terminal from  large heights     Do not allow a mechanical  shock to the product     Cleaning instructions  Clean the exterior by wiping it  with a soft  dry cloth  Do not  use much water     Do not use thinner  white spirit  or other solvents  These can  discolour the case and the  keys and has a negative effect  on the lifetime of the keys                          Cleaning of the terminal  Clean the optical interface window periodically     Cleaning of the cradle   Avoid touching the contacts in the cradle  The  contacts must stay as clean as possible to  maintain optimal charging capacity    Do not use water when cleaning the cradle   This can cause malfunction in the chargers     USER   S MANUAL PHL 1300 TERMINAL   IRU1300 CRADLE    Use of the terminal    kv    Avoid temperature changes   Sudden temperature changes  can cause condensation to  form on the terminal  Using the  terminal while condensation is  present can cause malfunction   Always wait until the condensation  clears naturally before attempting  operation     Do not leave the terminal in an  area where static charge is  accumulated  or near devices  where electromagnetic emission  is generated     Do not place any objects on top  of the terminal  Do not lay the  terminal face down    Doing so can cause accidental  operati
14. o the user s  situation     Operating power is supplied by the main  battery  The main battery may consist of a  rechargeable Li lon battery pack as supplied  with the terminal  or regular AA size dry cell  batteries     The cradle is a communication station for data  transmission between the  host  computer  system and the terminal  It communicates with  the terminal through their IrDA interface  The  cradle will also charge the rechargeable  battery pack in the terminal through the  electrical contacts     The IrDA interface on the terminal enables  you to communicate with other devices that  use IrDA communication  like portable  computers  notebooks and organisers        2 INSTALLATION       2 1 UNPACKING    When you remove the packing  please check  for any physical damage  We recommend that  you save all packing material  as it should be  used whenever you need to ship your terminal   eg  for service   Damage due to improper  repacking is not covered by the warranty     Apart from the terminal or cradle  additional  items might be ordered and supplied    If there are any missing parts please contact  your supplier     Do not remove the label     On the back of every unit you will find a label   The label is attached by the manufacturer and  includes information about the function it  supports and a serial number    Do not remove it     PHL1300     Terminal    Backup battery       Handstrap    ADDITIONAL  PHL1300     Battery pack    END   OPTICON  TALA EM Carita         
15. om the bar code              USER   S MANUAL PHL 1300 TERMINAL   IRU1300 CRADLE       5 PIN OUT    5 1 RS232 cable for cradle    9  ILS  DB 9  RS232   male female   Signal  In Out  cable  PC   cradle     CEE    not used   ON  fixed   ALN not used  C   ON  fixed        5 2 RS485 cable for cradle network    ly     Network   Modular Modular  cable plug plug  RS485  6P6   6P6        17    USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE       SPECIFICATIONS    6 1 SPECIFICATIONS TERMINAL       6 1 1 Electrical specifications    Main battery    Main battery  operating time    Backup battery    Backup battery  operating time    Battery  management       Lithium lon rechargeable   Opticon item    C Alkaline AA size batteries   optional user item           O Li lon  When making every 5  seonds 1 scan with 1 sec  laserbeam on and 0 2 sec   green LED on and 0 2 sec   buzzer on  operating time is   approx  36 hours   Alkaline  When making every 5  seonds 1 scan with 1 sec  laserbeam on and 0 2 sec   green LED on and 0 2 sec   buzzer on  operating time is   approx  78 hours   Different operation conditions   affect the operating time    Lithium CR2032    3 weeks backup time       Low voltage indicated on  the terminal display       When battery is low the  switches off automatically        6 1 2 Optical specifications  Light source 650 nm visible laser diode  Scan rate 100 scans sec  Decode rate 100 decodes sec  Reading width min  40 mm    at PCS 0 9   0 15 mm  6mil   Min  PCS Values 0 
16. on of the  PW  key or   ENTER  key  which can dis   charge your batteries or  change settings you do not  want to be changed     Use of the cradle  Do not place any other product than the  PHL type terminal in the cradle     Maintenance    gh            Q    There are no user serviceable  parts inside the terminal or the  cradle  So do not try to take it  apart  The manufacturer will not  be liable for any damage  caused by the customer     In case of malfunction that can not be solved  by the trouble shooting instruction in the  appendix  please consult our service    department     USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE    2 4 ASSEMBLY    Follow the next steps to make your terminal  ready for installation in a system  that is  described further in the manual     2 4 1  Terminal  To avoid drop use the hand strap     I  Fix the small cord of the strap around the  pillar of the terminal  ref  1    I Insert the handle of the strap in the thin  loop  ref  2    C  The strap is fixed to the terminal  ref  3    C  Hold the handstrap around the wrist when  carrying the terminal  ref  4     po not swing the terminal around        Start with a full battery    I  To be sure of proper operation  it is  advised to start with a full battery   charge the battery pack according to the  instructions in the next chapter    C  Click the battery pack into the terminal   as instructed in the next chapter     10    2 4 2 Cradle  Place for mounting    DO Place the cradle in normal offic
17. ries   When other batteries are used  defects or  other problems can occur  Before installing   new  batteries  please make sure you are  using the recommended batteries     OD  not make a mistake regarding the  polarity         of the battery   The terminal will not work when the  polarity is incorrect     O Use the right charger for batteries  The rechargeable Li lon battery pack of  Opticon can be charged in the cradle  IRU1300 when it is in the terminal   Other rechargeable batteries need to be  recharged in a separate battery charging  device     1 Follow the instructions for installing   changing and removing the batteries  very strictly    The products are not warranted for  damage  defects  malfunction or loss of  data  resulting from incorrect use of  batteries     11    USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE    2 5 1 Required batteries    The terminal needs both main battery and  backup battery for operation     Main Battery   The main battery can consist of    C  Rechargeable Opticon battery pack  Li lon    to be recharged when placing the terminal  PHL1300 in the cradle IRU1300    This battery is supplied with the terminal  and is recommended by Opticon    C  Pen lite batteries    Batteries that are not supplied by Opticon  must be AA size and absolutely leakproof   If rechargeable batteries are used  they  need to be recharged by a separate  battery charging device     Backup Battery  Use only one type of battery for backup   C  Backup cell    CR2032 L
18. storage   Shock  drop  1 5 m drop onto concrete surface    Shock  vibration  10   50 Hz with 1G for 30 min   cycle for X Y Z        Ambient light I  fluorescent 3 000 lux max   rejection F direct sun 50 000 lux max   Emission According to EN50081  part 1  Immunity According to EN50082  part 1  Safety  According to IEC825    Laser class Class   laserproduct    6 1 6 Physical specifications  Dimensions  I x w x d  132 x 55 x 33 mm  Case material ABS    Weight body  incl  battery   ca  170 g     depending on battery type        6 2 SPECIFICATIONS CRADLE    6 2 1 Electrical specifications  9V DC    Battery charging time when battery in terminal   8 hours charge    Power supply    6 2 2 Functionality    Interfaces supported    RS232  O RS485    Serial communication    RS232 Baudrate    1200   115200   TM RS485 Baudrate   1200   115200       Transmission modes     Half duplex RS232  T Half duplex RS485    Parity Odd  Even  None       6 2 3 Environmental specifications    Temperature   0 40   C in operation  D  20   70   C in storage  Humidity T 30   85   in operation   non condensing  T 30   90   in storage    10   50 Hz with 1G for 30  min  cycle for X Y Z     According to EN50081  part 1  According to EN50082  part 1       Shock  vibration     Emission    Immunity    6 2 4 Physical specifications  Dimensions  lx w x h  134 x 78 x 75 mm  Case material ABS    RS232   D Sub 9P Female  RS485   6 pins modular plug    Standard connector    19    USER   S MANUAL PHL1300 TERMINAL   IRU13
19. that the scanner has  effectively recognised and decoded the bar  code  In most cases  the application program  will provide an indicator signal or a buzzer  signal to indicate a good read to the user     When the read is incorrect you can try again     paying attention to the instructions in this  chapter     16    Da terminal is a Class   laser product  conforming to the strictest laser safety  standards  However  we recommend that  you avoid looking directly into the laser  beam emitter  or pointing the laser beam  directly into someone   s eyes     Fit the bar code in the laser beam from  margin to margin and pass the scanner  downward over the bar code  as shown in the  scan position illustration     N      M    incorrect read  scan positions    When reading a small bar code  decrease the  distance between the terminal and the bar code   For larger bar codes  position the terminal so  that the bar code fits into the laser beam   When reading a very high density bar code   decrease the distance between the terminal  and the bar code  For a low density bar code     increase the distance between the terminal  and bar code           good read  scan position          4 2 Barcode reading problems    When the barcode can not be read  try the   following    I  Change the angle between the bar code   and the terminal    C Change the distance between the bar   code and the terminal    I  If the bar code is larger than the laser  beam  try moving the terminal a bit further  away fr
20. the special pin out of the  connectors  use the cables supplied  by the manufacturer      lt  when you need another cable for a  certain device  that is not supplied   contact your supplier to purchase the  right cable  In case another cable is  used  take notice of the pin out  specifications further in this manual     2 6 1 Single cradle    DB25   DB9  m                       et 73 DBO    CRADLE RS 232    2 6 2 Cradle network      TRANSMISSION  HOST                RS 232    TERMINATED   RS 485  sw 1   on  sw 2   on  sw 3 on    14       Connection sequence   for single cradle    I  Place the cradle in normal office conditions   avoid a place under strong light   Disconnect the power supply    Set the required DIPswitches for   baud rate and function    Connect the interface cables    Connect the power supply    Place the PHL1300 terminal in the cradle        OOO dd    Connection sequence   for cradle network    I  Set all cradles to the same baud rate  by   DIPswitch    C  Only 1 cradle in the network will be  connected to the PC through one RS232  cable  On this cradle the DIPswitch for  RS232 connection must be enabled   Through this connection all cradles can  communicate to the PC    CT  A maximum of 16 cradles can be  connected in a network through RS485  cables  For the cradles that are not  directly connected to the PC the  DIPswitch for RS232 connection must  be set to off    I  The first and the last cradle in the network  must have the termination resistors set by 
21. typical use  for input of alpha numeric and  punctuation characters    ENT key O definable by application  typical use  for confirming input    Backup battery case cover  for housing backup battery    Main battery case cover  for housing main battery    Hand strap pillar  for attaching hand strap    Optical interface window  for infra red communication    Electrical contacts  for power supply from the cradle IRU1300  to terminal    USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE    2 2 3 Dimensions of cradle 2 2 4 Details of cradle                                 1  DC input socket  input for AC adaptor    2  RS 485 socket  for connecting another cradle in multi   drop RS485 network  through Opticon  RS485 cable    3  RS 232 C socket  for connecting to PC or modem   through Opticon RS232 cable    4  DIP switches  setting parameters of the infrared  interface     5  Electrical contacts  for power supply to terminal PHL1300  If rechargeable Li lon battery pack is  inserted in the terminal the pack will  be charged through the electrical  contacts    6  Optical window  window for optical data transmission    7  LED indicator  indicating power  LED on  power is on  LED off  poweris off       2 3 HANDLING PRECAUTIONS    To avoid malfunctioning and to ensure years  of trouble free operation  pay attention to the  following     General use    Do not use or leave the product  in extremely hot areas   like  direct sunlight  near a heater   or in a car   or in areas that are  very co
22. ver and fix its position  by screwing hand tight     USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE    GO O o    OPT  CON       2 5 6 How to  re  place the backup battery  in the terminal     1 Make sure that the main battery  is full enough while changing the          p y RECHARGEABLE  ni CR LITHIUM ION BATTERY   Lithium  button type  battery  LBP 1300       Part nr  ORBLIOP0020    IMSS 3 7V 900mAh  UP    GY 023    A CAUTION  DO NOT INCINERATE  DISASSEMBLE   SHORT  USE IN HIGH TEMP     DO NOT CHARGE EXCEPT  SPECIFIED CHARGING CONDITION   Lock backup battery case cover        Position the case cover and fix its position DO NOT CRUSH OR MODIFY   by screwing hand tight  Then press here MADE IN JAPAN    BOTTOM         Unlock backup battery case cover   ref  a    CI Unlock the case cover by use of a small  crosshead screwdriver or swatch  screwdriver    C  Remove old battery by simply taking out         Installing backup battery   ref  b    C  Make sure that the positive side of the  battery is pointed upwards  visible  and  place it in the compartment                    OPTICON  dee   ma  ao     min ee  SEL wn CE               9  95    1     ES note  CITE PROD     Ye  y  gt          E        b         SERAL Ma        ot St   ven Se      Engen pu       13    USER   S MANUAL PHL1300 TERMINAL   IRU1300 CRADLE    2 6 INSTALLING IN A SYSTEM    O Exercise caution at all times when  working with AC powered equipment     Dari off your devices before  installation      gt  Because of 
23. w of the   cradle and or terminal  and try again    D Check all cables   When the power indicator is still not  green  the cradle needs service           No data transmitted   D The cradle will only work if connected to  a PC       Clean the optical interface window of the  cradle and or terminal  and try again     D Data is corrupted  or no data is  transmitted    C Is the proper baudrate selected   The computer needs the same baudrate  as the terminal    IC  Clean the optical interface window of the  cradle and or terminal  and try again     The terminal looses data when the battery  pack is removed for a short period      gt  The backup battery is empty   Ci Replace the Lithium CR2032 battery by  a new one     PROBLEMS    When the terminal has a problem with  reading the label      lt  gt  The resolution of the bar code is too  high       Decrease the distance between the bar  code and the terminal     D The angle between the label and the  terminal is too high     CI Change the angle between the bar code  and the terminal     D The distance is too far or too close   Ci Change the distance between the bar  code and the terminal     2 The bar code is larger than the laser  beam     CI Try moving the terminal a bit further away  from the bar code        The read window is dirty   C  Clean the read window of the terminal     D The type of the bar code label is not  enabled     CI Enable the bar code symbology in the  application program     21    USER   S MANUAL PHL1300 TERMI
    
Download Pdf Manuals
 
 
    