1. 5 12 Start up sequence For simulations of start up click the Start button on the Control screen and specify the following parameters e Initial rotor speed the rotor speed at the start of the simulation e Initial pitch angle the pitch angle at the start of the simulation The built in start up logic may be used in which case the following parameters should be entered to define the sequence of events e Initial pitch rate during start up the constant pitch rate which will be used during the start up sequence e Generator speed at which generator is put on line As soon as the generator speed reaches this value the generator is connected to the grid and the power production control starts to act However any pitch angle demanded by the controller will be ignored until the initial pitch ramp is complete as defined by e Final pitch angle in start up mode The Initial pitch rate during start up continues to act until this pitch angle is reached at which point any pitch angle demanded by the power production controller starts to be used Alternatively click Defined by external controller to use your own start up logic Notes 1 The sign of the Initial pitch rate must be consistent with the initial and final pitch angles if the final pitch angle is less than the initial pitch angle the pitch rate must be negative and vice versa 2 Pitch angles and rates apply also to aileron flap airbrake deployment angles Th
2. 19 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 4 DEFINING THE REST OF THE TURBINE Having defined the turbine blades this section describes how to build up a model of the complete turbine structure including the rotor and hub power train tower and nacelle 4 1 Defining the rotor Click the Rotor icon on the toolbar to define the basic characteristics of the turbine rotor and hub The following data must be defined e Rotor diameter e Number of blades e Hub height from the ground to the centre of the rotor i e the intersection of the blade and shaft axes e Tower height from the ground to the top of the tower See also Tower e Blade set angle the angle at which the blade is mounted onto the hub i e the angle between the blade reference plane and the plane or cone of rotation of the rotor More positive values of set angle push the leading edge further upwind It is usually convenient to define the set angle as zero but particularly for stall regulated machines the set angle provides a simple way of rotating the whole blade without having to re define the twist distribution Cone angle the angle between the blade axis and the rotor plane normally positive Tilt angle the angle between the shaft and the horizontal normally positive Overhang the horizontal distance between the rotor centre and the tower centreline Lateral offset the horizontal offset between the shaft and
3. For each blade station click the box to indicate whether or not that information is required Having defined the blade stations required specify for each individual output whether that information is required on the First blade All blades or not at all None For the loads this can be specified independently for each of the following loads e Bending moments and shear forces resolved in out of plane and in plane directions These loads can also be requested resolved into flapwise and edgewise directions which are in the local blade axis system i e resolved perpendicular and parallel to the local blade chord 78 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Radial forces e Pitch moments For the blade deflections this can be specified independently for in plane and out of plane deflections 7 19 2 Tower outputs Click Tower outputs on the output specification screen Tower loads may be generated at any or all of the tower stations For each tower station click the box to indicate whether or not the loads are to be output there Having defined the tower stations required specify for each individual output whether that information is required For the loads this can be specified independently for each of the forces and moments 7 19 3 Other outputs Click Other outputs on the output specification screen and select which of the output files are required These include for example
4. This gives the aerodynamic parameters including local aerodynamic loading at each blade station assuming uniform steady wind flow e Performance coefficients Power torque and thrust coefficients are calculated assuming a uniform steady wind field e Steady power curve This gives power torque and thrust as a function of wind speed assuming a uniform steady wind field e Steady operational loads This calculates all the loads in a uniform steady wind field e Steady parked loads Loads on the parked turbine are calculated in steady wind As the blade position is specified the wind field need not be spatially uniform e Model linearisation This calculation is only available with an additional license Small perturbations are used to generate system responses from which the Linear Model post processing calculation is then able to derive a linearised model of the turbine in state space form This is of particular value for designing controllers 7 4 Simulations Simulations are used to calculate the loads deflections and other parameters of the wind turbine as a function of time using the full dynamics of the system driven if desired by a time varying wind input They may be used for example to simulate the behaviour of a turbine for period of say 10 minutes at each of a number of wind speeds so that the resulting loads can be analysed to produce a representa
5. argument DLL interface version number reserved for future use Tower top fore aft acceleration Tower top side to side acceleration Pitch override Torque override Reserved Rotor azimuth angle No of blades Max number of values which can be returned for logging Record number for start of logging output Max no of characters which can be returned in OUTNAME Number of variables returned for logging Reserved Blade 1 3 root in plane bending moment Generator start up resistance Rotating hub My GL co ords Rotating hub Mz GL co ords Fixed hub My GL co ords Fixed hub Mz GL co ords Yaw bearing My GL co ords Yaw bearing Mz GL co ords Request for loads 1 Variable slip current demand at position 81 Variable slip current demand Nacelle roll acceleration Nacelle nodding acceleration Nacelle yaw acceleration First generator speed in look up table First generator torque in look up table Second generator speed in look up table Second generator torque in look up table etc until Last generator speed in look up table Last generator torque in look up table Message length only if record 49 lt 0 Message text 4 characters per record Variables returned for logging output 107 of 116 FINAL See note s Units 15 6 6 6 6 P m s m s 16 16 rad 7 7 5 7 I7 Nm ohm phase 18 Nm 18 Nm 18 Nm 18 Nm 18 Nm 18 Nm 18 11 11 A 18 rad s 18 rad s
6. 61 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Extreme wave height the height of the regular wave defined from trough to crest e Wave direction from North the bearing from which the waves arrive at the tower 6 13 Defining Currents To define currents click on the Waves icon on the toolbar and then select the Currents tab Three current components may be specified separately or in combination e near surface current e sub surface current e near shore current If more than one current is selected the velocity vectors are added linearly The form of each current profile is described in the Theory Manual Any specified currents will be ignored if the turbine is not offshore Section 4 4 3 Click the check boxes to select the requierd current components and enter the relevant parameters in the adjacent text boxes as described below 6 13 1 Near surface current e Mean wind speed 10m e Direction from North the bearing from which the current arrives at the tower Like wind and wave directions current direction is defined as the direction from which the current is coming from and not the direction that the current is going fo 6 13 2 Sub surface current e Surface velocity the observed current velocity at the sea surface e Direction from North the bearing from which the current arrives at the tower 6 13 3 Near shore current e Beach slope the gradient of the shore defined in d
7. Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Calculations and post processing e Model linearisation is not available except as a demo calculation e The following post processing calculations are not available except as demo calculations ultimate loads ultimate load cases linear model REFERENCES 1 Germanischer Lloyd Rules and Regulations IV Non marine technology Part 1 Wind Energy Section 2 1993 2 MATLAB the Language of Technical Computing www mathworks com 116 of 116
8. Hub loads rotating with the rotor Hub loads fixed frame of reference Drive train information Generator information Controller information Summary information includes teeter yaw and pitch angles rotor azimuth aerodynamic gearbox and brake applied torque hub wind speed rotor speed power output 7 19 4 Co ordinate systems The co ordinate system for the loads and deflections is defined in Figures 6 28 1 to 6 28 3 on the following pages 79 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL ZB Radially along blade pitch axis XB Perpendicular to ZB and pointing towards the tower for an upwind turbine or away from the tower for a downwind turbine the picture shows an upwind turbine YB Perpendicular to blade axis and shaft axis to give a right handed co ordinate system independent of direction of rotation and rotor location upwind or downwind of the tower Origin At each blade station Figure 6 28 1 Co ordinate system for blade loads and deflections Blade loads may also be output in local co ordinates where X is perpendicular to the local chord line Y is parallel to the chord and Z is along the blade pitch axis The local chord line changes with set angle twist and pitch angle 80 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Mn lam Fon Hub loads in fixed frame of reference XN Along shaft axis and pointing towards the tower for
9. Tip speed ratio step the tip speed ratio interval required Pitch angle Rotational speed of the rotor The wind speed will be varied to give the required tip speed ratios at the specified rotational speed Although the performance coefficients are dimensionless they may depend on the wind speed or rotational speed and not just on the tip speed ratio because of Reynolds number effects 7 8 Power curve calculation Both steady state and dynamic calculations can be used to generate a power curve The steady state power curve calculation generates the wind turbine power curve as a function of wind speed assuming uniform steady winds Shaft and electrical power gearbox torque and thrust are calculated The dynamic power curve calculation performs a simulation at 70 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL each wind speed to produce a mean power curve with all dynamic effects including controller dynamics and the effects of turbulence included Use the Power curve screen see Calculation parameters to define the following parameters for the calculation e Minimum wind speed the low wind cut in speed e Maximum wind speed the high wind cut out speed e Wind speed step the wind speed interval required The remaining parameters are relevant for the steady state power curve calculation only e Calculate pitch and speed change select Yes to use the schedule defined by the generator and
10. e Highly non linear features may prevent a suitable linear model from being generated Examples might include tight pitch rate limits generator torque limits and the more complex pitch actuator models especially if they involve a ramp control bearing friction torque limits etc In such cases it is advisable to substitute a linear approximation to the actuator dynamics for example a second order passive model tuned to give a similar step response Step responses may be generated using a simple external controller to generate step changes in demand e For the model linearisation calculation it is usually desirable to find steady state values for all the states at each operating point To do this switch on the Refine Initial States option in Simulation control 7 12 Pitch and speed schedule For Steady Power Curve and Steady Operating Load calculations the pitch and rotor speed schedule represents the appropriate steady state pitch or aileron angle and rotor speed corresponding to any particular wind speed The schedule is defined by e the steady state Controller for the pitch angle and also for the rotor speed in the case of a variable speed turbine and e the Generator for the rotor speed in the case of a fixed speed turbine 7 13 Simulation control Use the Simulation control screen see Calculation parameters to define various parameters which control the progress of a simulation These parameters are de
11. 178 PI and Discrete _External and click Define to specify the details 34 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 5 PI control PI or Proportional plus Integral controllers are widely used for closed loop controllers on wind turbines A PI controller with input x and output y has the form y K x Kiint x where K Proportional gain K Integral gain and int x is the time integral of x The input x is the deviation of a measured quantity from its desired level or set point The output y is the demanded control action which is intended to minimise those deviations Bladed has the following built in PI controllers Fixed speed pitch regulated x deviation of measured power from the set point y pitch angle demand Variable speed torque control x deviation of measured generator speed from the set both stall and pitch regulated point y generator torque demand Variable speed stall regulated x deviation of shaft power from the set point power control y generator speed set point Variable speed pitch x deviation of measured generator speed from the set controller point y pitch angle demand Various control design techniques are available to help with the selection of the gains K and K However the design of controllers is a specialist task The main aim is usually to minimise deviations from the set point without excessive control action and witho
12. 18 rad s 3 5 rad s 3 5 Nm 3 5 rad s 3 5 Nm 3 5 rad s 3 5 Nm 15 15 17 SI Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL continued Notes 1 Pitch regulated case only 2 Not for variable speed pitch regulated case 3 Variable speed case only 4 Based on free wind at hub position no modelling of actual nacelle anemometer or wind vane 5 If the look up table option is selected for the optimal mode below rated control then record 16 is zero record 25 contains the record number R of the start of the look up table and record 26 contains the number of points in the table N 6 DLL case only see Sections 5 8 2 and A 3 7 DLL case only see Section A 5 8 in data supplied by simulation which may be used but not changed by the external controller out data supplied by the external controller to the simulation both data which is written by the simulation but which may be changed by the external controller 9 Record type for EXE case I integer R real floating point C character In the DLL case all records are actually passed as 4 byte real floating point numbers 10 0 off 1 main high speed or variable speed generator 2 low speed generator 11 Only used with the variable slip generator electrical model Set record 80 to 1 if using record 81 to send a rotor current demand If record 80 is 0 default then the torque demand record 47 will be used to control
13. An aerofoil dataset is a look up table of Lift coefficient Drag coefficient and Pitching moment coefficient optionally as a function of angle of attack Such tables are usually obtained empirically for particular aerofoil sections at particular Reynolds numbers for example in wind tunnel tests 3 7 1 Defining aerofoil datasets Bladed maintains a database of aerofoil datasets Click the Aerofoil icon on the toolbar for access to the database As well as the table of aerodynamic coefficients each aerofoil dataset is characterised by a set of general data giving the characteristics of the aerofoil section to which it applies namely Name this is an the identifier for referencing the dataset within Bladed Comments to identify the source of the data and the full name of the aerofoil section Thickness to chord ratio for the aerofoil section Reynolds number for which the dataset applies Pitching moment centre the point about which the aerodynamic pitching moment is defined as a percentage of the chord backwards from the leading edge Deployment angle for aileron sections e Include pitching moment set to No if the pitching moment data is not available If any dataset used on the turbine does not have pitching moment data defined then no pitching moments will be calculated for that turbine If possible give angles of attack ranging from 180 up to 180 as the full range will be needed for some calculations 3 7 2 Importin
14. In the DLL case only additional data may be sent back to Bladed for logging in additional simulation output files in a similar format to other simulation outputs This data can then be viewed directly using the Data View facility or post processed This is particularly useful for debugging the controller or for illustrating the details of its operation Element 62 of the DATA array gives the maximum number of logging outputs which can be returned On the first call the DLL should set element 65 to the number of logging outputs which will be returned and their values should be returned starting at the element whose number is given by the value of element 63 The OUTNAME array can be used to specify the names and units for the logging outputs This should be set on at least the first and last calls to the DLL overwriting the existing information in that array This array should be set to a sequence of characters as follows Name Units repeated for each logging output Name is a description of the logging output and Units should be one of table A 2 provided the logging output is presented in strict SI units See Appendix B1 for an example in C 110 of 116 Garrad Hassan and Partners Ltd Allowed values for Units 1 T A A P A PT A PTT A T A TT F F L F LL FL FL A FL L FLL FLT A FLTT AA I L L T L TT LLL LLL A M L M LLL M LT MLL S lt 40572 Document 282 BR 010 ISSUE 11 FINAL Meaning
15. OUTNAME where xxx is any suitable file extension not beginning with The number of characters in the name is given in DATA see Appendix A Alternatively or in addition the DLL may send information back to Bladed for output in the same form as the other simulation results This is described in Appendix A MESSAGE The address of the first record of an array of 1 byte characters which may be used by the DLL to send a text message to Bladed which appears on the screen and is stored together with any other calculation messages generated by Bladed 5 8 3 Using a user defined controller To use your own controller for any of the control functions select the External Controller option where appropriate on the Control Systems or Yaw Control windows To specify your controller select the External Controller tab on the Supervisory Control window on the Control Systems window Define buttons are provided for this in appropriate places Then specify the following information Controller code the compiled exe or dll file which runs your controller a dialogue box allows you to select the appropriate file Communication Interval the controller timestep At these regular intervals Bladed will send information to the external controller and expect to receive information in return In real life the controller will take some time to calculate its outputs usually a whole timestep so it may be appropriate for the controlle
16. Only the order is important DATA The address of the first record of an array of single precision 4 byte real numbers which is used for data exchange between the simulation and the controller The contents of the array is given in Appendix A FLAG A 4 byte integer passed by reference which the DLL should set as follows 0 if the DLL call was successful gt 0 if the DLL call was successful but the MESSAGE should be issued as a warning message The simulation will continue 40 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL lt 0 if the DLL call was unsuccessful or for any other reason the simulation is to be stopped at this point MESSAGE is then issued as an error message INFILE The address of the first record of an array of 1 byte characters giving the name of the parameter file which is currently DISCON IN See section 5 8 3 This array should not be modified by the DLL The number of characters in the name is given in DATA see Appendix A OUTNAME The address of the first record of an array of 1 byte characters giving the simulation run name prefixed by the full path to the directory which will contain the simulation results This may be useful if the controller wishes to write a permanent record of what it does to be stored with the simulation results the results should be stored in a file whose name including path is generated by appending xxx to
17. and Data View used to see the results 5 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL At the preliminary design stage various turbine parameters can be adjusted and all these calculations can be repeated rapidly until satisfactory results are obtained As further data is defined more complex calculations can be carried out For example by defining suitable combinations of drive train generator and control characteristics it becomes possible to calculate the steady power curve and steady operational loads with the rotor speed and or pitch angle varying with wind speed as appropriate After defining the numbers of vibrational modes on the Modal screen along with the necessary mass and stiffness information as indicated on the Calculations screen it becomes possible to perform a Modal analysis calculation Blade and tower bending can then be taken into account in the calculations Simulations can also be performed once the Simulation control and Time varying wind modules are defined As always the minimum data required is always indicated on the Calculations screen making it easy to ensure that the necessary data is defined for each calculation to be done Note also the Show options button at the bottom of the Calculations screen This provides a rapid means of switching particular features off or on for a particular calculation For example provided the energy losses module has been defined the energy los
18. and pitch moment coefficients tabulated against angle of attack One such look up table is referred to here as an aerofoil dataset A number of aerofoil datasets may be combined to define one aerofoil section Two types of aerofoil section may be defined Normal Sections for any fixed or pitchable part of blade with no flaps or ailerons Separate aerofoil datasets may be provided for up to three fixed Reynolds numbers Interpolation between these datasets will occur depending on the precise Reynolds number at any point in the calculation For each of the fixed Reynolds numbers aerofoil datasets may be provided for two different thickness chord ratios one either side of the actual thickness chord ratio for the blade station in question In this case a further interpolation will be carried out to give aerodynamic coefficients appropriate to the actual thickness chord ratio Aileron Sections for any parts of the blade which have flaps ailerons airbrakes or other aerodynamic control surfaces which alter the aerodynamic profile of the blade section Separate aerofoil datasets may be provided for a number of different deployment angles of the control surface Interpolation between these datasets will be used to give aerodynamic coefficients appropriate to the actual deployment angle at any point in the calculation 14 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 3 7 Aerofoil datasets
19. strict SI No units specified s Hz rad rad W rad Ws rad Ws rad s rad s N N m N m Nm Nm rad Nm m Nm Nms rad Nms rad A m m s m s m m rad kg kg m kg m kg ms kgm No units specified Table A 2 Allowed Units 111 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL APPENDIX B Example External Controller Code In Selected Languages To assist the user to get started with the coding required for external controllers this appendix presents a few simple examples B 1 Simple example of DLL code written in C include lt stdio h gt include lt string h gt define NINT a a gt 0 0 int a 0 5 int a 0 5 extern C avoid mangled names void _declspec dllexport _ cdecl DISCON float avrSwap int aviFail char accInfile char avcOutname char avcMsg Main DLL routine void _declspec dllexport _ cdecl DISCON float avrSwap int aviFail char accInfile char avcOutname char avcMsg char Message 257 InFile 257 OutName 1025 float rTime rMeasuredSpeed rMeasuredPitch int iStatus iFirstLog static float rPitchDemand Take local copies of strings memcpy InFile accInfile NINT avrSwap 49 InFile NINT avrSwap 49 1 0 memcpy OutName avcOutname NINT avrSwap 50 OutName NINT avrSwap 50 1 0 Set message to blank memset Message 257 Set constants SetParams avrSwap Load vari
20. xq to give feed forward action Filter time constant T4 prevents excessive high frequency gain of the differential term Additional detail on the pitch actuator model can be found in the Bladed theory manual 5 11 The shaft brake Click the Brakes button either on the Transmission screen or in the Supervisory Control section of the Control Systems screen to define the dynamic characteristics of the shaft brake The mechanical shaft brake is used for simulations of stopping or parked rotors When the brake is applied it usually takes a little time to reach full torque Two ways are provided for specifying how the brake torque develops Select Linear Ramp or Look up Table by clicking the appropriate button Linear ramp model The brake torque increases linearly from zero up to full braking torque Enter the following data in the boxes provided e Maximum shaft brake torque the full braking torque and e Shaft brake ramp time the time to reach full torque starting from zero Look up table The braking torque may be specified as a time history of braking torque against time since the brake application was initiated Use the Add button to add points to the time history 4 6 2 See Drive train to specify the position of the brake 45 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 14 sys 5 16 See also Normal stop sequence Emergency stop sequence Parked conditions
21. 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL is modified using the assumption of incompressible inviscid flow around a cylinder of diameter F D where D is the tower diameter at the height where the tower shadow is being calculated Empirical model For rotors operating downwind of the tower use this empirical model which uses a cosine bell shaped tower wake Enter the following parameters e Maximum velocity deficit at the centre of the wake as a fraction of the local wind speed e Width of the tower shadow as a fraction of the local tower diameter e Reference position the distance downwind as a proportion of the local tower diameter at which the above parameters are defined At other distances the shadow width increases and the velocity deficit decreases with the square root of the distance from the tower Combined model This model uses the potential flow model at the front and sides of the tower and the empirical model on the downwind side wherever it gives a deficit greater than the potential flow model deficit with a smooth transition between the two This is useful in simulations where the rotor might yaw in and out of the downwind shadow area 6 4 Upwind turbine wake If the turbine rotor being modelled the target turbine is wholly or partially immersed in the wake of another turbine operating further upwind use this option to define the modification to the steady state mean wind profile cause
22. CDECS ATTRIBUTES DLLEXPORT DISCON CDECS ATTRIBUTES ALIAS DISCON DISCON The Lahey LF90 compiler needs this line instead DLL EXPORT DISCON lFor other compilers read the documentation to find out how to do this REAL AV_ avrSWAP NTEGER 1 accINFILE avcOUTNAME avcMSG NTEGER aviFAIL NTEGER 1 iInFile 256 iOutName 1024 iMessage 256 CHARACTER cInFile 256 cOutName 1024 cMessage 256 EQUIVALENCE iInFile cInFile iOutName cOutName iMessage cMessage NTEGER I iStatus REAL rTime rMeasuredPitch rMeasuredSpeed rPitchDemand SAVE rPitchDemand This just converts byte arrays to character strings for convenience DO 1 NINT avrSWAP 50 iInFile I accINFILE I Sets cInfile by EQUIVALENCE ENDDO DO 1 NINT avrSWAP 51 iOutName I avcOUTNAME I Sets cOutName by EQUIVALENCE ENDDO Load variables from Bladed See Appendix A iStatus NINT avrSwap 1 rTime avrSwap 2 rMeasuredPitch avrSwap 4 rMeasuredSpeed avrSwap 20 Read any External Controller Parameters specified in the User Interface IF iStatus EQ 0 THEN aviFail ReadData cInFile cMessage User to suppply this routine rPitchDemand rMeasuredPitch Initialise ENDIF Set return values using previous demand if a sample delay is required avrSwap 45 rPitchDemand Main calculation User to suppply calcs routine IF iStatus GE 0 AND aviFail GE 0 THEN aviFail calcs
23. T indicator At the bottom enter the turbine lifetime and ensure a wind speed distribution is defined The wind speed distribution parameters will not be used if all the load cases are transient and the length of transient simulations will not be included in the turbine lifetime If available for each variable enter the number and range of the bins to be used If the Minimum and Maximum are both left as zero a bin range will be calculated which is suitable across all the load cases For rainflow cycle and fatigue analysis it is possible to specify a minimum range below which cycles are not counted 8 16 Ultimate Loads This calculation scans a number of load cases to find the maximum and minimum values of a specified set of variables and records the simultaneous values of all the other variables in the list From the Ultimate Loads window click Define Channels and Load Cases to open the Multiple Processing window Use the Add Load Case and Add Variable buttons to build up the required lists of load cases and variables For users with the Advanced Post Processing module a list of Load Case Groups can be set up along with their corresponding safety factors A check box on the Load Cases tab enables these to be assigned to the load cases During processing the safety factors will then be applied Safety factors may also be assigned to individual variables and these will override the group safety factor Each load case should
24. The actuator force limits are assumed constant so at other pitch angles the torque limits will be reduced Pich angle Linear actuator geometry at the maximum torque Radius am A position Ifthe pitch angle decreases with increasing ram RAs lergh L length set the ram length L to be negative L Single actuator the parameters supplied relate to a single actuator controlling all the blades together One actuator per blade there is a separate actuator for each blade and the parameters supplied relate to each actuator This option must be selected if individual pitch control is to be used Blade pitching inertia the inertia about the pitch axis for a single blade undeflected Bearing friction the friction torque on each bearing is the sum of a constant term a term proportional to the applied bending moment and a term proportional to the applied axial force on the bearing i e the radial force acting outwards along the pitch axis and a term proportional to the radial force on the bearing i e the magnitude of the vector sum of the blade in plane and out of plane shear forces at the bearing position Bearing stiction when stationary the break out torque is equal to the bearing friction torque described above plus an additional stiction torque This stiction torque is represented by a constant torque plus a term proportional to the friction torque 5 10 1 Passive dynamics Click the appropriate Define button and enter t
25. Upwind turbine wake 52 6 5 No time variation of wind speed 53 6 6 Single point wind history 53 6 7 3D turbulent wind 54 6 8 Transients 55 6 9 Definition of wind direction 57 6 10 Generating turbulent wind fields 58 6 10 1 Defining turbulence characteristics 58 6 10 2 Advanced options 59 6 10 3 Generating the wind field 60 6 11 Annual wind distribution 60 6 12 Defining Waves 60 6 12 1 None no waves 61 6 12 2 Jonswap Pierson Moskowitz spectrum 61 6 12 3 User defined spectrum 61 6 12 4 Extreme deterministic waves 61 6 13 Defining Currents 62 6 13 1 Near surface current 62 6 13 2 Sub surface current 62 6 13 3 Near shore current 62 7 EXECUTING WIND TURBINE CALCULATIONS 63 7 1 Modal analysis 63 7 1 1 Defining the modes 63 7 1 2 Performing the calculation 64 7 1 3 The modal frequencies 64 7 2 The calculations screen 64 7 2 1 Calculations available 65 7 2 2 Data required for calculations 65 7 2 3 Calculation options 65 7 2 4 Specifying outputs 65 7 2 5 Calculation parameters 66 7 2 6 Executing a calculation 66 7 2 7 Batch processing 66 7 2 8 Retrieving calculation details 68 7 3 Steady calculations 68 iii Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 7 4 Simulations 68 7 5 Calculation parameters 69 7 6 Aerodynamic information calculation 70 7 7 Performance coefficients calculation 70 7 8 Power curve calculation 70 7 9 Steady operational loads calculation 71 7 10 Steady parked loads calculation 71 7 11 M
26. also be set off from the Calculations pull down menu on the toolbar Post processing and supporting calculations may also be set off from the relevant data entry screen 7 2 7 Batch processing Some calculations notably long simulations with high frequency dynamics may take as long as several hours to run Use the batch system to store the complete details of one or more calculations which can then be run at a later time for example overnight Use the Run in Batch button instead of the Run now button on the Calculations window When all the required calculations have been added to the batch the calculations may be started using the Batch List window accessed from the Batch menu item on the main toolbar 66 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL A number of different batch queues may be maintained Each batch must be in a separate directory The Batch menu item on the main toolbar gives access to the Batch List screen This shows all the calculations in the batch queue and allows the user considerable flexibility in managing batch queues as described below Directly from the batch list you may View the status of each batch job Enable or disable any batch job by double clicking on it Select one or more jobs for subsequent operations Delete one or more jobs from the batch list Move a job up or down the queue using the arrow buttons Start the batch run Abort the entire batch run Clear th
27. although power factor control is not available The maximum slip should also be supplied Alternatively the electrical dynamics model can be selected in which case the following additional parameters are required to define the variable slip control Additional controlled resistance the additional resistance which is connected in series with the generator rotor and controlled to vary the slip Proportional gain the proportional gain of the PI controller which adjusts the additional resistance in response to the normalised rotor current error and Integral gain the integral gain of the PI controller If a two speed variable slip generator is selected torque control is only possible for the main generator A variable speed pitch regulated controller should be selected for use with variable slip generators see also Variable speed control below rated 4 9 Energy losses The Power Train button on the toolbar also allows the energy losses to be specified Power train energy losses are divided into mechanical and electrical losses 4 9 1 Mechanical losses A choice of two options is available to specify mechanical losses for convenience Select Expressed as torque to specify a loss torque in kNm or Expressed as power to specify a power loss in kW Then enter either a constant loss in the box or click the appropriate Add button s as required to create a look up table This may be a simple look up table on shaft speed or
28. an upwind turbine or away from the tower for a downwind turbine the picture shows an upwind turbine ZN Perpendicular to XN such that ZN would be vertically upwards if the tilt angle were Zero YN Horizontal to give a right handed co ordinate system independent of direction of rotation and rotor location upwind or downwind of the tower Hub loads in rotating frame of reference XN Along shaft axis and pointing towards the tower for an upwind turbine or away from the tower for a downwind turbine the picture shows an upwind turbine ZN Perpendicular to XN such that ZN would be aligned with blade 1 axis if the cone angle were zero YN Perpendicular to XN and ZN to give a right handed co ordinate system independent of direction of rotation and rotor location upwind or downwind of the tower Origin At hub centre intersection of blade and shaft axes Figure 6 28 2 Co ordinate system for hub loads 81 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL XT Pointing South ZT Vertically upwards YT Pointing East Origin At each tower station Note that for steady state calculations the wind is deemed to blow from the North Figure 6 28 3 Co ordinate system for tower loads and deflections The yaw bearing is assumed to be located at the top tower station The co ordinate system for yaw bearing loads is the same as for the top tower station except that it rotates with the nacelle The co ordinat
29. and bearing details must be supplied The response of the actuator to a torque demand is represented by a passive Ist 2nd or higher order response generating an actual torque Click Define to enter the appropriate parameters For an instantaneous response select a first order model with zero time constant The resulting torque is subject to limits as specified This model is useful for electric actuation systems but could also be used for hydraulic systems operated by direct control of the hydraulic pressure Select a rotary or linear actuator as appropriate The rotary model is particularly useful for electrical actuators while the linear model is useful for hydraulic cylinders The rotary model requires the following parameters Gearbox ratio the step down ratio from pitch motor speed to pitch rate Gearbox efficiency this represents the torque loss in the gearbox Rotational inertia the motor inertia referred to its own shaft For the linear actuator model the gearbox ratio would normally be 1 0 and the effective inertia is likely to be small enough to neglect The actuator torque is defined for the maximum torque position of the actuator when the ram is tangential to the pitch circle 43 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Click the Geometry button to define the corresponding pitch angle and the actuator length between pivots when in this position and also the radius arm
30. brake is applied to bring the rotor to rest if it has not already been applied as a result of grid loss or overspeed The emergency stop begins at the Time to begin a stop specified in Simulation control Alternatively click Defined by external controller to use your own emergency stop logic Note that the Time to begin a stop does not apply in this case Notes 1 Pitch angles and rates apply also to aileron flap airbrake deployment angles They are ignored if the rotor has no aerodynamic control surfaces 2 User defined supervisory control may also be defined in an external controller 5 15 Idling conditions For simulations of an idling rotor click the Idling button on the Control screen and specify the fixed pitch or aileron angle to be used while idling Click Enable external controller if any user defined control logic is to be used 47 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 16 Parked conditions For simulations of a parked rotor click the Parked button on the Control screen and enter e the fixed pitch or aileron angle to be used when parked and e the rotor position or azimuth angle when parked note that this position is used at the start of the simulation but it is possible for the brake to slip allowing the azimuth to change during the simulation A zero azimuth angle means that the first blade is pointing vertically upwards Click Enable external con
31. capable of reading and writing to shared files or as a 32 bit DLL dynamic link library A DLL is preferable as it will result in faster simulations and communication with Bladed may be more reliable 5 8 1 Writing a user defined controller as an executable program If the controller is written as an executable it will use a shared file for two way communication with Bladed When the simulation starts up the controller executable exe file is first copied into the directory where Bladed is installed and renamed discon exe When discon exe starts up the Bladed directory is the current directory and the files used to communicate between the simulation and the controller are in this directory The controller program can therefore refer to these files by name without giving the full path Two files are used to communicate between the user defined controller program and the simulation One of these is a text file named discon aux which is written by the simulation and just contains the directory and run name for the simulation results This may be useful if the controller wishes to write any permanent record of what it does to be stored with the simulation results The file has just two lines the first consists of the word PATH followed by a space and then the path for the simulation results including the final backslash The second line consists of the word RUNNAME followed by a space and then the run name i e up to 8 characters The control
32. cone within which the blades themselves experience no aerodynamic forces Blade root section The blade root section connects the blade root to the shaft It is assumed to be cylindrical in section It is defined by e Length this defines the actual radius of the first blade station Set this to zero if there is no root section The rotor diameter must be twice the sum of the root section length and the blade length defined by the radial position of the last blade station e Diameter the diameter of the cylindrical tube which forms the blade root section e Drag Coefficient the drag coefficient to be used for any part of the blade root section which is outside the spinner Zero lift coefficient is assumed If the spinner entirely covers the root section the diameter and drag coefficient values will not be used For one and two bladed rotors click the check box to specify a teetered hub if required See also Options For teetered hubs enter a Delta 3 angle if pitch teeter coupling is required A positive delta 3 angle acts to stabilise teeter by increasing the angle of attack when the blade teeters into the wind A Special setting is available in case other forms of pitch teeter coupling are required by special arrangement with Garrad Hassan Teeter restraint If a teetered hub is selected a teeter restraint system may be specified by clicking the Teeter restraint button Mass information For dynamic calculations
33. control Blade 1 3 root out of plane bending moment Blade 2 pitch angle Blade 3 pitch angle Generator contactor Shaft brake status 0 off 1 on Nacelle angle from North Reserved Demanded yaw actuator torque Demanded blade 1 individual pitch position or rate Demanded blade 2 individual pitch position or rate Demanded blade 3 individual pitch position or rate Demanded pitch angle Collective pitch Demanded pitch rate Collective pitch Demanded generator torque Demanded nacelle yaw rate 106 of 116 FINAL See note s Units s s rad 1 rad 1 rad 1 rad rad s rad s rad rad s 2 W 3 W W 3 5 Nm rad s 3 rad s 3 rad s 1 3 rad s rad s rad s 3 Nm 3 Nm 4 rad 3 5 Record no 3 5 4 m s 18 Nm rad rad 10 rad 2 rad 12 14 rad or rad s 12 14 rad or rad s 12 14 rad or rad s 12 rad 12 rad s Nm 13 rad s Garrad Hassan and Partners Ltd continued Record Data Data number 49 49 50 51 52 53 54 55 56 57 59 60 61 62 63 64 65 66 68 69 71 R 2N 2 R 2N 1 Mo M M L onwards continued overleaf Document 282 BR 010 ISSUE 11 flow type Description out in in in in in in out out out 1n out out both in in in in in in in in in out out out I r a a Al ADA Message length OR Mo Maximum no of characters allowed in the MESSAGE No of characters in the INFILE argument No of characters in the OUTNAME
34. controller to define the pitch angle and rotor speed at each wind speed see Section 6 21 Select No to calculate a simple power curve at fixed pitch angle and rotor speed If No is selected also supply the following e Fixed pitch angle e Fixed rotational speed of the rotor 7 9 Steady operational loads calculation This calculation generates wind turbine loads as a function of wind speed assuming uniform steady winds This optionally includes blade tower and other loads see Output Control It also includes the calculation of partial derives which are useful for control design and in particular for gain scheduling Use the Steady loads screen see Calculation parameters to define the following parameters for the calculation Minimum wind speed the low wind cut in speed Maximum wind speed the high wind cut out speed Wind speed step the wind speed interval required Calculate pitch and speed change select Yes to use the schedule defined by the generator and controller to define the pitch angle and rotor speed at each wind speed see Section 6 21 Select No to calculate a simple power curve at fixed pitch angle and rotor speed If No is selected also supply the following e Fixed pitch angle e Fixed rotational speed of the rotor 7 10 Steady parked loads calculation 71 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL This calculation generates wind turbine loads fo
35. defined on the Rotor screen The Show button controls the graphical display of tower properties The graph is updated as soon as any new values are assigned giving an instant indication if faulty values are entered Controls are provided to print the graph or save it to a Metafile which can subsequently be incorporated into a report Check the Mass check box to allow the mass per unit length to be entered at each tower station This is necessary for correct calculation of the tower base loads and also for modelling tower vibrations in which case it is also necessary to check the Stiffness check box and supply bending stiffness values at each station These are defined as the product of the Young s modulus and the second moment of area Alternatively for a tower of circular cross section the mass and stiffness distributions can be calculated automatically by entering the wall thickness at each station Type the name of a material and enter its density and Young s modulus in the boxes provided A number of different materials may be entered if desired Then select the appropriate material for each station If a discontinuity is to be defined for example a step change in wall thickness or other property simply enter two stations at exactly the same height to define the discontinuity Do not enter very closely spaced stations 4 4 2 Flanges and point masses Flanges should be modelled as point masses not by an increase
36. dynamic drive train model where there is a flexible shaft between the rotor and the shaft brake 63 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL For the tower modes supply also e Azimuth angle for the rotor zero azimuth is with blade pointing vertically upwards at which the modes are to be calculated As the azimuth changes with rotor rotation the modal analysis will clearly be approximate for all other positions but in practice this inaccuracy is usually small It is very important to choose a self consistent set of rotor modes as follows 1 For non teetered rotors set the number of out of plane modes to a multiple of the number of blades 2 If the hub rotation is locked see above set the number of in plane modes to a multiple of the number of blades Otherwise use nB or nB 1 in plane modes where B is the number of blades and n is an integer 7 1 2 Performing the calculation Having defined the modes to be modelled as above click the Calculate button Alternatively click the Calculations icon on the toolbar to bring up the Calculations screen if it is not already present Select Modal analysis and then Run Now 7 1 3 The modal frequencies When the modal analysis is complete click Results to view the modal frequencies which have been calculated Alternatively return to the Modal analysis screen click the Modal button on the toolbar if the screen is not alread
37. foundation moment of inertia and rotational stiffness If neither is selected a rigid foundation is assumed Note The Turbine Information window shows the total masses and inertias of all turbine components whose mass characteristics are defined Click the Mass totals button or use the Windows pull down menu on the main toolbar to open this window 4 5 Defining the power train Click the Power Train button on the toolbar to define the following aspects of the power train e the transmission gearbox and shafts any flexible mountings the generator the energy losses and the network to which the turbine is connected 4 6 Transmission The Power Train button on the toolbar allows the drive train or transmission to be specified The transmission consists of the gearbox and shafts Two alternative ways of specifying the drive train are provided e Locked speed model e Dynamic model 4 6 1 Locked speed model This model is available for simple calculations in which the turbine rotor is assumed to rotate at an absolutely constant speed The rotor speed is specified along with the gearbox ratio but 24 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL no other characteristics of the drive train nor of the generator may be specified Flexible mountings cannot be modelled either This model is useful for initial aerodynamic design of fixed speed rotors but fo
38. in wall thickness between closely spaced stations Click the Point masses button to define the height and additional mass of each flange or other point mass 4 4 3 Environment Click either Land or Sea in the Environment panel to define whether the turbine is sited onshore or offshore The Tower Geometry diagram will then show either the ground level or the sea bed and mean water level as appropriate To change the water depth relative to the base of the tower change the Depth of first tower station as appropriate 23 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Enter the aerodynamic drag coefficient to enable windage forces and aerodynamic damping to be calculated For an offshore turbine enter also the hydrodynamic drag and inertia coefficients to enable wave and current forces and hydrodynamic drag to be calculated and the mean sea depth For a description of wave and current loading see the Theory Manual 4 4 4 Foundation If the tower mass and stiffness check boxes have been checked it is also possible to define the mass and stiffness properties of the foundation which can have a significant influence on the tower vibrational properties Use the check boxes to specify whether translational and or rotational motion at the tower base are to be taken into account If translation is selected enter the foundation mass and translational stiffness in the appropriate boxes If rotation is selected enter the
39. modes In the subsequent calculations the modes are coupled together by the equations of motion so that the actual eigenfrequencies of the coupled system may change The Model Linearisation calculation allows the coupled modal frequencies to be calculated First it is necessary to decide how many modes of vibration are to be modelled 7 1 1 Defining the modes To define the modes required click the Modal button on the toolbar For the rotor enter the number of out of plane and in plane modes to be used For the tower enter the number of fore aft and side to side modes required Then for each mode enter the structural damping required for each mode by clicking the Modal damping button For the rotor modes the following additional data is required e Number of pitch angles the modal analysis may be carried out at several pitch angles The modal frequencies will then be interpolated for intermediate pitch angles e Pitch angles enter the pitch angles to be used for the modal analysis e Rotational speed supply a value representative of the rotor speed to be used in the simulations This need not be precise since as the rotor speed varies the appropriate centrifugal stiffening corrections will be applied to the modal frequencies e Hub rotation select Locked if the locked speed drive train model is being used or for most parked rotor calculations Select Free for all other non parked cases and for parked cases with the
40. on the screen the data may also be copied into the clipboard for transfer to another application This is sometimes quicker than sending the table directly to EXCEL For a large table it is sometimes faster to send it to an ASCII file first and then read the file into EXCEL 9 10 Refreshing graphs Click Refresh Data to re read any plot data which has changed since it was last read in for example in the case of a plot of results from a simulation which is still in progress or if a calculation has been repeated overwriting the old results Any channel can be forcibly re read using the Data pull down menu Select the Auto refresh graph every option to re read the graph data at the specified time intervals This is useful for a graph to update itself automatically as a simulation progresses If the interval is set to zero the graph will not update the View button will now use the same graph window each time it is pressed rather that opening a new window each time From the pull down menu use Data gt Change runs to read new graph data from one or more different runs for the same variables 9 11 Graph configurations The File pull down menu allows you to save and load Bladed Graph Configurations bgc files which contain all the necessary details to re create a graph the graph size the channel definitions styles and also axis limits and graph annotation whether fixed or automatic When loading a configuration a prompt allows th
41. provided there is sufficient data e Minimum range the smallest signal range to be counted as a cycle A non zero value may be useful to remove the effect of any spurious noise on the signal 8 12 Setting bin limits Several calculations require minimum and maximum values to be entered for the bin range These values should encompass the entire data range For automatic calculation of suitable bin limits set the minimum and maximum to be equal or leave them both blank Alternatively the actual minimum and maximum of the signal may be found by running the Basic statistics calculation 8 13 Annual energy yield This calculation generates the annual energy yield of a wind turbine from either a steady state 7 8 7 14 power curve a dynamic power curve or a series of power production simulations as a function of annual mean wind speed assuming either a Weibull Rayleigh or a user defined distribution of wind speeds Click the Select button to define the power curve to be used Then enter the following data e Minimum wind speed the cut in wind speed for the turbine e Maximum wind speed the cut out wind speed for the turbine 90 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Wind turbine availability the average availability assumed to be uncorrelated with wind speed Define the wind speed distribution by clicking the Define button I
42. set of graphical icons and a number of pull down menus The Calculations screen allows the user to select define and execute a particular calculation There are various ways of opening further screens which allow the user to define the characteristics of the various parts of the wind turbine as well as the characteristics of the wind and various parameters which control the execution of calculations There is also a graphics facility for viewing results 2 1 1 Main toolbar pull down menus The pull down menus may be used as follows File use this menu to create open and save project files and to import modules from other project files A project file prj contains wind turbine information and or parameters defining calculations The project file header information may be edited and a security password entered to prevent the file being modified by unauthorised users Using the file type selector on the File Open dialogue box it is also possible to open a project backup file prx or a file containing all the details relating to a calculation previously carried out pj This is useful for re running the calculation with or without modifications Use the Import facility to import individual modules from other project or calculation details files into the currently active project Specify this menu allows the user to move directly to a particular screen for specifying any part of the wind turbine or any calculation or load cas
43. suitable for many calculations More complex models are useful for detailed calculations particularly if pitch actuator loads and detailed behaviour need to be simulated Proceed as follows Input signal select whether the command received from the controller is a pitch position demand or a pitch rate demand Individual pitch control Select this if the user defined controller will generate separate pitch demand signals for each blade Selecting this option will also cause the pitch actuators 42 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL on each blade to be modelled individually so that the loads for each will be output separately Otherwise only the mean loads across all the actuators will be output Response to pitch position demand if the input signal is a pitch position demand specify the actuator response as Passive 1st 2nd or higher order models are provided or Active and click Define to specify the appropriate parameters In the Active case a PID controller on pitch error generates a pitch rate demand An optional Ramp Control is provided which converts step changes in raw position demand coming from the discrete controller into a smooth profile based on the specified rate and or acceleration limits Response to pitch rate demand if the input signal is a pitch rate demand or if it is pitch position but the response to is Active then the response to the pitch rate
44. tabulated by clicking the Tabulate button Select whether to view the tabulated data on screen or send it to an ASCII file a WORD document or an EXCEL spreadsheet Click Stats to tabulate the mean minimum maximum and standard deviation of the selected datasets 9 1 Graphs of several variables In the case of two dimensional graphs it is possible to plot up to six datasets on one graph Simply click additional channel selection buttons to define the data required Click the Clear buttons to remove unwanted channels Any channel may also be disabled temporarily by means of the check box on the right hand side 9 2 Graph styles Two dimensional graphs may be displayed as line graphs points or bar charts by clicking the appropriate Style button on the Graph Parameters screen In the same way three dimensional graphs may be displayed as surface plots or column plots 9 3 Grids and logarithmic axes Use the check boxes on the Graph Parameters screen to specify whether or not to add X and Y grids to the graph and whether or not to plot on logarithmic axes in the X and or Y directions Logarithmic axes are only available on two dimensional graphs The Darker grids option may be useful for printing the graph to some black and white printers The feint grid lines may not always appear depending on the printer driver 98 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 9 4 Units A units selection box to
45. that no data is available 4 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL to perform the selected calculation while a yellow light indicates that some of the required data has been defined but not all Below the calculations is a small window showing all the data modules which need to be defined in order for the selected calculation to be performed Double clicking on one of these data modules immediately opens up the relevant screen in which the data for that module is defined It is therefore a simple matter having selected the calculation to be performed to work through all required data modules which are still undefined and assign the relevant data 2 1 4 Sequence of operations Before any wind turbine calculations can be done it is necessary to specify the principal characteristics of the blades and rotor Open the relevant screens by one of the means described above i e from the Specify pull down menu from the relevant Toolbar icon or from the Calculations screen with one of the wind turbine calculations selected In order to be able to define the aerodynamic characteristics of the blades it is necessary to enter or import the relevant aerofoil datasets into the aerofoils database if it is not already present using the Aerofoil icon on the toolbar or from the Specify pull down menu It is also necessary to define the following modules e Physical constants although standard values will have bee
46. the generator 12 See record 28 13 See record 29 14 Depending on record 10 15 EXE case only see Section A 3 16 See Section A 4 17 DLL case only see Section A 5 18 Record 79 is used to request additional measured loads and accelerations to be provided by the simulation Blade loads and Hub rotating Yaw bearing Record 79 accelerations loads Hub fixed loads loads 0 1 y 2 V V 3 y y y 4 y y y y Table A 1 Communication records Note the strict use of SI units for all variables Note also that many of the parameters passed from the simulation to the controller are constants as defined in the Control Systems window and some are variables such as measured signals Some are only relevant for certain types of controllers e g fixed or variable speed stall or pitch control and pitch position or pitch rate actuators Although the record numbers are always the same as shown in the tables above the user defined controller need only make use of those parameters which it actually requires and only needs to output the demands which are relevant for the particular case e g 108 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL demanded pitch angle s for pitch regulated machines with pitch position actuator demanded pitch rate s for pitch regulated machines with pitch rate actuator demanded generator torque for variable speed machines demanded nacelle yaw rate if the external controller option wa
47. the parameter required is e Number of bins the number of azimuthal bins to be used in the calculation minimum 4 maximum 144 More bins will generally give a more accurate result but do not choose more bins than the number of signal samples in one revolution of the rotor 8 5 Auto spectrum This calculates the auto spectral density frequency spectrum of a signal Click the Select button to define the signal to be processed If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results for each load case will then be stored as additional outputs of that load case Then enter the information required as follows e Number of points per segment power of 2 maximum 4096 e Percentage overlap See Section 8 5 1 e Window select e Remove trends check box 8 5 1 Options for spectral analysis All calculations involving spectral analysis use a Fast Fourier Transform technique with ensemble averaging To perform the spectral analysis the signal is divided into a number of segments of equal length each of which contains a number of points which must be a power of 2 The segments need not be distinct but may overlap Each segment is then shaped by multiplying by a window function which tapers the segment to zero at each end This improves the spectrum particularly at high frequencies A choice of windowing functio
48. with Matlab 2 A state space model has the following form 94 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL x Ax Bu y Cx Du where u is a vector of inputs x is a vector of system states and y is a vector of outputs A B C and D are the state space matrices First click Select to define which variables from the Model linearisation results are required as model outputs The model states will depend on the dynamics which were selected in the wind turbine model for that calculation and the inputs will include wind speed pitch angle demand and generator torque demand The state space matrix coefficients are calculated as the slope of a best fit line through a number of points generated by perturbations of different sizes away from the steady state condition The Minimum acceptable correlation coefficient defines whether a best fit will be accepted or not If the correlation is poorer than this that particular matrix coefficient is set to zero A value of 0 5 is generally suitable Two output files are created in the selected output directory using the selected run name and the following file extensions lt RunName gt mat This is a mat file suitable for reading directly into Matlab 2 lt RunName gt m2 This is an ASCII text file also suitable for reading into Excel containing the same information Each file contains the four state space matrices for each operating point and also w
49. 067 8 0 48 0 0107 0 078 4 0 02 0 0073 0 089 0 0 45 0 0061 0 104 4 0 891 0 0069 0 121 8 1 323 0 016 0 119 12 1 728 0 0218 0 116 16 2 119 0 07 0 111 20 2 478 0 225 0 112 180 0 0 0 0 0 0 0 ENDSECTION 17 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 3 9 Defining normal aerofoil sections A normal aerofoil section should be defined for every blade station which is either e Fixed see Blade geometry or e Moving see Blade geometry and pitchable see Control surfaces Normal aerofoil sections allow interpolation on up to three Reynolds numbers and up to two thickness chord ratios see Aerofoil sections A very flexible interpolation scheme is used so for example it is not necessary for the individual datasets to have matching angles of attack A number of different aerofoil sections may be defined for use at different blade stations On the Blade properties window click on the foil section to be defined A drop down list allows an already defined section to be selected or select Define to open the Define Aerofoil Sections window This allows the characteristics of already defined sections to be viewed or edited or new ones created by clicking New To view or edit an existing aerofoil section In the Define Aerofoil Sections window select the section number required To set up a new aerofoil section In the Define Aerofoil Sections window press New to star
50. 2 Fourier harmonics This calculation generates the fourier components of a signal at multiples of rotor rotational frequency Click the Select buttons to define the signal to be processed and the signal representing rotor azimuth If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results for each load case will then be stored as additional outputs of that load case Then choose either automatic or manual selection of parameters Automatic selection is usually adequate but if entered manually the parameters required are e Number of bins the number of azimuthal bins to be used in the calculation minimum 4 maximum 144 More bins will generally give a more accurate result but do not choose more bins than the number of signal samples in one revolution of the rotor e Number of harmonics the number of harmonics to be calculated minimum 1 maximum one quarter of the number of bins 8 3 Periodic components This calculation separates out the periodic and stochastic parts of a signal Click the Select buttons to define the signal to be processed and the signal representing rotor azimuth If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results for each load case will then be stored as additional outputs o
51. 5 2 to 5 7 below Further details of the power production controllers is provided in the Theory Manual It is also possible for user defined control logic to be used see Section 5 8 Supervisory control The Supervisory control screens may also be accessed by clicking the Control icon on the toolbar Use the Supervisory control screens to define the characteristics of the following Shaft brake Start up sequence Normal stop sequence Emergency stop sequence Idling conditions Parked conditions Yaw control User defined controllers Pitch actuators 5 16 In built supervisory control logic is available for stops and starts but the user may also supply the required logic for these as well as for yaw control 31 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 1 Fixed Speed Stall Regulated Control There is no in built controller for fixed speed stall regulated turbines so no parameters need be entered in this case However clicking on Dynamics will allow the speed and power transducer dynamics to be defined even though these are not used for power production control The transducer signals are available so that an external controller can have access to them if desired Click on Use external controller for pitch airbrake control if an external controller will be used to control any pitchable blades tips or ailerons In thi
52. Add button to add a new tower station Stations are automatically sorted by height To highlight a station click on the station number or a graph point Click Delete to remove a highlighted station To enter or edit data highlight the data item by clicking on it or by moving to it using the arrow keys and then pressing the Return key Press Escape to restore the previous value 22 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Highlight a block of cells by dragging the mouse These cells may be copied to the clipboard or the contents of the clipboard may be pasted in In this way data from a spreadsheet or a tab delimited ASCII file may be directly pasted in Click Undo to reverse a paste operation Enter the tower station height and tower diameter for each station In the case of an onshore turbine the station heights are defined relative to ground level whilst for an offshore turbine station heights are defined relative to the mean water level If the first tower station is above the ground or sea bed level the tower is assumed to be mounted on a rigid pedestal as indicated on the Tower Geometry diagram If the height of the first tower station is below the ground or sea bed level the tower foundation is assumed to be buried as indicated and no external forces are assumed to act on the buried portion of the tower For all cases the height of the top tower station must correspond to the tower height
53. GH Bladed Version 3 51 User Manual Document No 282 BR 010 Classification Commercial in Confidence Date June 2003 Author E A Bossanyi Checked by D Witcher Approved by D C Quarton DISCLAIMER Acceptance of this document by the client is on the basis that Garrad Hassan and Partners Limited are not in any way to be held responsible for the application or use made of the findings of the results from the analysis and that such responsibility remains with the client Key To Document Classification Strictly Confidential Recipients only Private and Confidential For disclosure to individuals directly concerned within the recipient s organisation Commercial in Confidence Not to be disclosed outside the recipient s organisation GHP only Not to be disclosed to non GHP staff Client s Discretion Distribution at the discretion of the client subject to contractual agreement Published Available to the general public 2003 Garrad Hassan and Partners Limited Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL CONTENTS 1 INTRODUCTION 1 1 1 Installation 1 1 2 Optional modules 1 1 3 Support 2 1 4 Documentation 2 1 5 Acknowledgements 2 2 USING Bladed 3 2 1 General description and layout of the user interface 3 2 1 1 Main toolbar pull down menus 3 2 1 2 Toolbar icons 4 2 1 3 The calculation window 4 2 1 4 Sequence of operations 5 2 2 Entering data 6 2 3 Using project files 6 2 4 P
54. Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 8 User defined controllers Although Bladed has a full set of built in controllers both for power production control and for supervisory control a wide range of different control algorithms is used in practice by different turbine manufacturers The controller details can have a profound effect on turbine loads and performance so it is important to allow the flexibility to use any control logic the user wishes to define Also it is worth considering whether the same code can be used for controlling Bladed simulations as is used in the actual turbine controller Bladed allows a user defined controller to be used for any of the following tasks e Control of blade pitch and generator torque across the whole range of operation including power production normal and emergency stops starts idling and parked conditions e Control of the shaft brake and generator contactors e Control of nacelle yaw You may use a mixture of user defined and built in controllers for the various different controller functions Note that the user defined controller operates on a discrete timestep like most real controllers The built in controllers operate in continuous time but can be used to approximate the behaviour of a discrete controller as long as its timestep is not too long The user defined controller may be written in any language either as a DOS or Windows executable program exe
55. To specify such a discontinuity highlight the blade station at the radial position where the discontinuity lies and click the Split button to split the blade station into an inboard and an outboard station at the same radial position The data may then be specified differently on either side of the discontinuity A split station may be re joined if necessary to remove the discontinuity by clicking the Join button 3 2 Blade geometry The blade geometry is defined at each blade station clicking on the data item to be defined or changed The following data is required at each station e Distance from root the distance from the blade root to the current blade station It must be zero for the first station e Chord the distance from the leading edge to the trailing edge i e along the chord line e Twist the angle between the chord line and the blade reference plane More positive values of twist and set angle push the leading edge further upwind The blade is assumed to be twisted about the quarter chord point e Thickness the thickness of the blade as a percentage of the chord at that station 11 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Pitch axis the distance from the leading edge to the blade pitch axis as a percentage of the blade chord at that station measured from the leading edge towards the trailing edge For a non pitching blade an arbitrary axis may be defined Pitching momen
56. a window appears in which a directory can be selected into which the calculation outputs will be placed If the directory does not exist it will be created A run name is also required Thus a number of calculations may be placed in the same directory each with a different run name There is also the option to select ASCII or binary format for the calculation results Binary format gives much smaller files and should be faster and more accurate Graph plotting post processing and tabulation all work with either format If you want to see the raw numbers from binary files you can still tabulate the numbers to the screen an ascii file Excel or Word If a whole series of calculations is to be performed for example a set of simulations for different load cases which might include stops and starts as well as normal running and parked conditions in a series of different wind conditions some thought should be given to the directory structure used and the file extensions used within each directory For example a tree structure could be used with a sub directory for each group of load cases Each individual load case could then be in its own sub directory or different extensions could be used within the directory for example to indicate different mean wind speeds Bear in mind also the need for post processing results to be stored for each load case Some post processing results may also be summed over a series of load cases Calculations may
57. abilities Main module Steady state calculations Saving project files Writing reports Graphics Simulation module Modal analysis Simulations Turbulent wind Waves Standard post processing Batch module Running calculations in batch mode Linearisation module Generation of linearised turbine models Advanced post Automatic loads reporting batch plotting processing Available in the educational version Restrictions apply in the educational version 1 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 1 3 Support Bladed is supplied with a one year maintenance and support agreement which can be renewed for further periods This support includes a hot line help service by telephone fax or e mail Telephone 44 0 117 972 9900 Fax 44 0 117 972 9901 E mail bladed bristol garradhassan co uk It is Garrad Hassan policy to work with clients to respond to their needs so that the software can be constantly improved As with any software of this complexity a total absence of bugs cannot be guaranteed and any reports of bugs along with comments or suggestions on any aspect of the software are welcomed The maintenance and support agreement includes free provision of any revisions or upgrades of the software during the period of the agreement Modifications to the software to meet the individual needs of specific clients can be made be arrangement Such work will be charged for at commercial ra
58. ables from Bladed See Appendix A iStatus NINT avrSwap 0 rTime avrSwap 1 rMeasuredPitch avrSwap 3 rMeasuredSpeed avrSwap 19 Read any External Controller Parameters specified in the User Interface if iStatus 0 aviFail ReadData InFile Message User to supply this routine rPitchDemand rMeasuredPitch Initialise Set return values using previous demand if a sample delay is required avrSwap 44 rPitchDemand Main calculation User to supply calcs routine if iStatus gt 0 amp amp aviFail gt 0 aviFail calcs iStatus rMeasuredSpeed rMeasuredPitch amp rPitchDemand OutName Message Logging output example avrSwap 64 2 No of outputs iFirstLog NINT avrSwap 62 1 Address of first output strcpy OutName Speed A T Pitch A Names and units avrSwap iFirstLog rMeasuredSpeed First Value avrSwap iFirstLog 1 rMeasuredPitch Second value Return strings memcpy avcOutname OutName NINT avrSwap 63 memcpy avcMsg Message MIN 256 NINT avrSwap 48 return 112 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL B 2 Simple example of DLL code written in FORTRAN 90 SUBROUTINE DISCON avrSWAP aviFAIL accINFILE avcOUTNAME avcMSG IMPLICIT NONE Compiler specific Tell the complier that this routine is the entry point for the DLL The next two lines are for the case of the Digital Visual Fortran compiler
59. ads e Inertial loads this safety factor will multiply the inertial component of output loads e Wave loads this safety factor will multiply the hydrodynamic component of output loads for offshore turbines Note the use of these partial safety factors is no longer recommended Safety factors should rather be applied during post processing of the loads No safety factors are applied to other outputs such as drive train generator and summary information deflections velocities etc 7 18 Imbalances and Pitch Failures 77 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Use the Imbalances and Pitch Failures window see Calculation parameters to define any mass imbalance of the rotor or errors in the set angle or the pitch angle of one or more blades and to specify pitch failure cases Enter the following data e Imbalance mass the part of the rotor mass which is out of balance Note this is not an additional mass the total rotor mass is not changed by this parameter e Radius of imbalance the radial position of the centre of gravity of the imbalance mass e Azimuthal position of imbalance zero means the imbalance mass centre of gravity is on blade 1 e Time for pitch failure if Pitch failure mode see below is set to At time T enter the time at which the failure will occur e Error in blade set angle for each blade specify the error in set angle see Rotor e Error in pitc
60. ait 1 millisecond Compiler dependent subroutine It may be unneccessary but may help to prevent problems on a slow network ELSEIF iSTATUS EQ 1 THEN Read from swap file READ iUNIT REC 2 IOSTAT iERROR rTime READ iUNIT REC 4 IOSTAT iERROR rMeasuredPitch READ iUNIT REC 20 IOSTAT iERROR rMeasuredSpeed ta IF iStarted EQ 0 THEN iFail ReadData DISCON IN User to suppply this routine rPitchDemand rMeasuredPitch Initialise ENDIF Set return values using previous demand if a sample delay is required WRITE iUNIT REC 45 IOSTAT iERROR rPitchDemand Main calculation User to suppply calcs routine IF iStarted GE 0 AND iFail GE 0 THEN iFail calcs iStarted rMeasuredSpeed rMeasuredPitch rPitchDemand ENDIF iStarted 1 ELSE STOP Handshake status incorrect ENDIF CLOSE iUNIT ENDDO STOP END 114 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL APPENDIX C The Bladed Demo Bladed can be run for demonstration purposes if no security device is available A demo project demo_a prj is supplied with Bladed and will be found in the installation directory This contains simplified details of a representative but artificial 3 bladed 2MW offshore variable speed pitch regulated turbine This can be used to run any of the available calculations The Bladed demo is restricted as follows Operation Restrictions Modal analysis calculation Turbine
61. aking and or the shaft brake to stop the rotor in the event of a loss of load Either braking mechanism may be tripped either by the loss of load or by a specified overspeed condition For simulations of emergency stops click the Emergency stop button on the Control screen To use the built in logic for emergency stops specify the following parameters e Emergency pitch trip mode Select Overspeed if aerodynamic braking is to be triggered by an overspeed or Grid loss if it is to be triggered immediately on loss of load e Rotor speed at which pitch motion commences The overspeed condition which triggers the aerodynamic braking if Emergency pitch trip mode is set to Overspeed e Emergency pitch rate the constant pitch change rate which is used following the Grid loss or Overspeed e Maximum pitch the final pitch angle If the Emergency pitch rate is negative the Maximum pitch should actually be the most negative pitch angle The initial pitch angle will depend on the running conditions before the stop occurs e Emergency shaft brake trip mode Select Overspeed if the shaft brake is to be triggered by an overspeed or Grid loss if it is to be triggered immediately on loss of load e Rotor speed for cut in of brake speed control The overspeed condition which triggers the shaft brake if Emergency shaft brake trip mode is set to Overspeed e Rotor speed for cut in of brake for parking when the rotor has slowed down to this value the shaft
62. ampbell diagram The Campbell Diagram calculation is available for all users with a Simulation licence or an Educational licence It generates state perturbations and uses the resulting variations in the state derivatives to compute the eigenfrequencies of the coupled system This is repeated for a series of operatring points and the eigenfrequencies are then displayed on a graph as a function of rotor speed The operating points are defined in two ranges For low rpm the turbine is assumed to be idling Operating points are defined at a range of rotor speeds at a specified wind speed The idling pitch angle is defined by the Idling Conditions For power production a range of wind speeds operating points is defined and the rotor speed and pitch angle will then be determined by the power train and control system definition in the same way as for the Steady Power Curve A reasonable number of rotor speeds and wind speeds should be defined to obtain a useful number of points on the Campbell diagram For each wind speed and rotor speed it is also possible to specify a range of azimuth angles but this is not normally useful since the system dynamics are usually not significantly dependent on azimuth 72 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL The parameters required are as follows Rotor speed operating points define the minimum and maximum rotor speeds required in the idling range a
63. and minimum values of the wind speed and the moving average gust wind speed Click Max Gust Table to view a table of maximum moving average gust values at a grid of points after first specifying the spacing of the grid points required Note that this calculation may be quite slow 6 2 Wind shear Wind shear is the variation of steady state mean wind speed with height If wind shear is required click the Wind icon on the toolbar and select Wind shear Then select either the exponential or the logarithmic wind shear model Exponential model Enter the wind shear exponent The wind speed V h at height h above the ground is then given by h Qa V h vero 0 where h is the reference height and a is the wind shear exponent A zero exponent results in no wind speed variation with height Logarithmic model Enter the ground roughness height parameter The wind speed V h at height h above the ground is then given by log h vay va oe log hy Zo where h is the reference height and Z is the ground roughness height 6 3 Tower shadow Tower shadow defines the distortion of the steady state mean wind field due to the presence of the tower Click the Wind icon on the toolbar and select Tower shadow and select a model Potential flow model This model is appropriate for rotors operating upwind of the tower Enter the Tower diameter correction factor F The longitudinal wind velocity component around the tower 51 of
64. and then click either Run now or Run in Batch to store the calculation for later execution using the batch facility 6 11 Annual wind distribution Some post processing calculations require the annual distribution of hourly mean wind speeds to be defined This includes the Annual Energy Yield calculation as well as any calculations which produce weighted lifetime values for example of fatigue damage or damage equivalent loads Click the Wind icon on the toolbar and select Annual wind distribution Select either a Weibull or a user defined distribution For the Weibull distribution enter the mean wind speed and shape factor A shape factor of 2 results in a Rayleigh distribution For the user defined distribution enter the cumulative distribution or exceedance table starting with an exceedance of 1 0 at zero wind speed For wind speeds above the last point in the table the exceedance will be assumed to decay in proportion to exp v where v is the wind speed and k is the number entered as the Exponent for high wind speeds Click either Cumulative plot or Probability plot to view the wind speed distribution as defined 6 12 Defining Waves Click the Waves icon on the toolbar One of the following four options must then be selected e None no waves are required e Jonswap Pierson Moskowitz spectrum irregular waves with a standard energy spectrum are required e User defined spectrum irregular waves with a user defi
65. anual Since this representation includes modelling of the electrical losses in the generator and auxiliaries electrical losses may not also be specified under Energy losses The test box at the bottom may be used to enter a slip value allowing the power and power factor to be checked on both sides of the auxiliary load and power factor correction capacitors If Two speed operation has been selected enter all the relevant parameters for both the main generator and the low speed generator The code automatically determines which generator to use as follows e Steady calculations and simulation initial conditions if the wind speed is less than 13 m s the generator which gives the higher power is used otherwise the main high speed generator is used e Start ups using built in start logic the generator whose synchronous speed is closer to the speed specified for generator switch on is used An external controller can be used to determine which generator to use and to implement speed change logic 4 8 2 Variable speed generator This model should be used for a variable speed turbine It models both the generator and frequency converter A variable speed turbine requires a controller which generates a torque demand The variable speed generator is modelled as a first order lag from demanded torque to actual generator torque independently of rotational speed This is specified by the Power electronics time constant Note a
66. are no cross coupling terms To enter or edit data click on the appropriate entry or move to it with the arrow keys and press Return 13 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 3 5 Flap Twist Coupling Flap twist coupling allows the twist of the blade to change as a function of the flapwise deflection It does not introduce any additional torsional degree of freedom so purely torsional modes are not modelled Such modes generally have a relatively high frequency but if there is any purely torsional with a frequency lower than any of the modes being considered Bladed will issue a warning as the resulting behaviour would then be unrepresentative For calculations involving blade flap twist coupling it is necessary to define the mass moment of inertia per unit length the torsional rigidity which is the product of the shear modulus and the torsional constant and the position of the principal neutral axis for bending as a percentage of chord measured from the leading edge To enter or edit data click on the appropriate entry or move to it with the arrow keys and press Return 3 6 Aerofoil sections At each blade station the aerodynamic characteristics of the blade section must be defined so that lift and drag coefficients may be calculated Pitch moment coefficients may also be calculated if desired Aerodynamic characteristics are defined empirically by means of look up tables of lift drag
67. ations When only a part of the wind speed time history is used the mean wind speed obtained may be different from the nominal wind speed for that simulation Therefore it is important to plot the resulting power curve against the actual mean wind speed obtained and not against the nominal wind speed Note also that the actual mean wind peed obtained is the mean of the magnitude of the wind vector taking into account all three components of turbulence if used which is greater than either the mean longitudinal component or the mean horizontal component as measured by a cup anemometer 7 15 Aerodynamic models Use the Aerodynamics control screen see Calculation parameters to define various parameters which define how the aerodynamic calculations are carried out Parameters applicable to all calculations e Prandtl corrections Select whether or not to apply a Prandtl correction for tip loss and hub loss effects e Allowable error in flow induction factors specify the accuracy required for the induction factors A value of 0 001 is usually suitable Smaller values result in slower calculations but greater accuracy The inflow calculation is inappropriate for parked and slow idling cases and may be switched off at low tip speed ratios For Zero inflow below tip speed ratio enter the tip speed ratio below which the inflow calculation is switched off for Full inflow above tip speed ratio enter a tip speed ratio above which the
68. bine characteristics and the details of any particular calculation Calculation results can also be entered into the report in tabular or graphical form The report is prepared directly in Microsoft Word format Alternatively ASCII text format is available as an option if required but this clearly does not allow the inclusion of graphical output From the Reports menu on the main toolbar select the required report format from the following options ASCII to save the table as tab delimited ASCII text Word the default to save the table in a Microsoft Word document you must have Microsoft Word installed The current format can be saved as the default using the Save item of the Options pull down menu on the main toolbar There are two main ways of generating reports e Project reports these may contain any currently assigned modules defining the wind turbine itself as well as calculation parameters and wind field details if required e Calculation reports these may include any turbine details which are currently assigned and which are relevant to the calculation as well as details of the calculation itself and the wind field used if applicable They may be generated as stand alone reports or appended to another report such as a project report As well as adding graphs and tables the reports may also be edited and printed within Bladed 10 1 Project reports From the Reports menu on the main toolbar select Write project repor
69. bution should be less than the minimum stress e Maximum value the end of the stress distribution should be greater than the maximum stress e Number of bins suggest 20 A higher number maximum 128 will give finer resolution provided there is sufficient data e Minimum range the smallest signal range to be counted as a cycle A non zero value may be useful to remove the effect of any spurious noise on the signal If you select Calculate Equivalent Loads enter up to 10 inverse S N slopes to use for the calculation of equivalent loads These are the sinusoidal loads which would produce the same fatigue damage at the specified S N slope if the frequency of the sinusoid is as specified 8 11 Fatigue damage estimation This calculation generates fatigue damage estimates from a stress history or a previously generated rainflow cycle count by taking account of the fatigue properties of the material A suitable stress history can be generated from the relevant loads using the Channel combination calculation Click the Select button to either the stress signal to be processed or a previously generated rainflow cycle count not available for Multiple Channels If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results will be accumulated over the turbine lifetime Then enter th
70. bution should be less than the signal minimum e Maximum value the end of the distribution should be greater than the signal maximum e Number of bins suggest 20 A higher number maximum 144 will give finer resolution provided there is sufficient data e Remove mean check box If this is selected the distribution will be representative of deviations from the mean and so the distribution mean will be zero If Multiple Channels is selected the means will not be removed 8 8 Peak value analysis This calculation generates the probability distribution of the peaks and troughs of a signal Click the Select button to define the signal to be processed button to define the signal to be processed If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results will be accumulated over the turbine lifetime For each variable to be processed enter the following data e Minimum value the start of the distribution should be less than the signal minimum e Maximum value the end of the distribution should be greater than the signal maximum e Number of bins suggest 20 A higher number maximum 144 will give finer resolution provided there is sufficient data 8 9 Level crossing analysis This calculation generates the frequency with which a signal crosses given levels Click the Sel
71. cal position of the rotor within the wind field see Section 6 7 e Minimum and maximum allowed values of surface roughness the iteration will fail if the required gust cannot be achieved with a surface roughness between these limits e Minimum and maximum alongwind position of gust these can be used to ensure that the maximum gust is not too close to the start or end of the wind file e Use wind shear If this box is checked the wind shear will be taken into account in finding the maximum gust which will then be most likely to occur near the top of the rotor If used the wind shear may be specified in terms of a shear exponent or a roughness length Click Get current values to input the shear model as currently defined on the Wind screen e Number of files to generate If required this calculation can generate more than one file with different random number seeds which match the specified criteria In this case 59 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL the resulting wind files will be called name_n wnd where name is the run name selected and n is a sequential number 6 10 3 Generating the wind field Having defined the turbulence characteristics as above click the appropriate button to generate the wind field either Now or In Batch Alternatively click the Calculations icon on the toolbar to bring up the Calculations screen if it is not already present Select Wind turbulence generation
72. cessed The following sets are available Ultimate Loads histogram output Rainflow Cycle Exceedance Rainflow Cycle By Range Lifetime Weighted Equivalent Loads 9 12 3 Replacing runs If any runs in the graph configuration s are to be replaced they will be replaced by each item in the Runs list in turn Add any desired runs to the list click Add Many to add all the runs in a directory or a directory tree 9 12 4 Sequence Control The sequence control allows the user to specify the order in which the plots or tables will be generated 9 12 5 Tabulation of Ultimate Loads Select the Tabulation of Ultimate Loads to tabulate the Ultimate Loads from each of the ultimate loads calculations specified in the Runs list There is no graphical output available in this case 9 12 6 Output 101 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Use the options in the Output Requirements to specify what type of output is required and where it should be sent Graphs can be displayed on screen stored as metafiles and sent to a WORD document Tabulated data and statistical data can also be sent to a WORD document or to an ASCII text file If an output file is specified which already exists data will be appended to the end of the file 102 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 10 REPORTING The Bladed reporting system enables the user to generate reports describing the wind tur
73. ch angle will be set for normal operation below rated wind speed and the pitch or aileron angle will increase above rated If Assisted Stall is selected the Maximum pitch setting is used below rated and the pitch or aileron angle decreases or moves to more negative values above rated Demanded generator torque the maximum generator torque demand used as a constant torque demand above rated wind speed Demanded speed above rated the generator speed demand above rated This is usually the same as or slightly above the Optimal mode maximum speed Maximum generator speed must be greater than the Demanded speed above rated 5 4 2 Dynamic parameters This controller varies the generator torque to regulate the speed of the generator and rotor Above rated the torque is held constant and the speed is then controlled by adjusting the blade pitch angle controller dynamics Generator speed transducer Pitch actuator dynamics Torque control algorithm Pitch control algorithm The following information is needed for simulations which include See transducers A power transducer may also be defined if desired Enter the software rate limits for use in the control algorithm Click Actuator to specify the pitch actuator details Choose between PI and Discrete External and click Define to specify the details See also Variable speed control below rated Choose between P Pr
74. check the Mass checkbox to allow the necessary masses and inertias to be specified as follows e Hub mass the mass of the hub including the spinner and any blade root section e Hub mass centre the distance from the intersection of the shaft and blade axes to the centre of mass of the hub in a direction measured away from the tower e Hub inertia the moment of inertia of the hub mass about the shaft axis For direct drive systems enter also the generator mass information as follows e Generator mass e Generator mass centre the distance between the centre of mass of the generator and the centre of mass of the hub e Generator inertia the moment of inertia of the generator Note this is always required although not actually used for static calculations and for one bladed rotors only e C Weight Mass the mass of the counterweight e C Weight Inertia the moment of inertia of the counterweight about the shaft axis Note 21 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL The Turbine Information window shows the total masses and inertias of all turbine components whose mass characteristics are defined Click Mass Totals or use the Windows pull down menu on the main toolbar to open this window 4 3 Teeter restraint A spring and damper model of a teeter restraint system is provided If a teetered rotor has been specified click the Teeter restraint button on the Hub screen select Standard mo
75. contain an identifier which must be in upper case followed by an identifier consisting of up to 32 alphanumeric characters 16 of 116 Garrad Hassan and Partners Ltd REFNUM amp XA THICK REYN DEPANG NALPHA NVALS up to 32 characters lt real gt lt real gt lt real gt lt real gt degrees lt integer gt lt integer gt 2 or 3 Document 282 BR 010 ISSUE 11 FINAL A unique identifier for this dataset Any comment lines here starting with an asterisk will be incorporated in the database Pitch moment centre back from leading edge Thickness chord ratio Reynolds number Aileron deployment angle Number of angles of attack listed in the table Number of coefficients 2 if just lift and drag coefficients are available 3 if pitch moment coefficients are also present The table of coefficients follows consisting of NALPHA lines of data each containing Angle of attack degrees Lift coefficient Drag coefficient moment coefficient if NVALS 3 with the values on the line separated by commas spaces or tabs Finally there should be a line consisting of the termination string ENDSECTION A very simple example for an ASCII aerofoil database file just to illustrate the format required is given here REFNUM SET1 Example dataset Use these lines for a description XA 25 0 THICK 18 0 REYN 3 E6 DEPANG 0 0 NALPHA 12 NVALS 3 180 0 0 0 20 1 0 3 0 037 12 0 88 0 03 0
76. d by the wake of the upwind turbine Click the Wind icon on the toolbar and select Upwind turbine wake and choose between the simple Gaussian wake profile and the Eddy viscosity model For the simple Gaussian model two parameters define the wake profile e Centre line velocity deficit as a percentage of the local wind speed e Wake half width the distance from the wake centre line at which the deficit is reduced to e times the centre line value The eddy viscosity model carries out a full calculation of the wake based on the following characteristics of the upwind turbine Diameter Thrust coefficient Tip speed ratio Number of blades Distance upstream from the target turbine With this model the wake development depends on the ambient turbulence intensity For turbulent wind simulations the ambient turbulence is defined by the time varying wind definition Enter a default turbulence intensisty for use in other calculations 52 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL The eddy viscosity model also includes a calculation of the added turbulence generated by the wake For turbulent wind simulations the ambient turbulence defined in time varying wind will be increased accordingly A choice is provided to control how the added turbulence is interpreted for the lateral and vertical components of turbulence e Not calculated The added turbulence is ignored e Longitudinal only the
77. d job s into a buffer for subsequent pasting into another batch queue Paste jobs from the buffer into the current batch Move a selection of jobs to a different place in the queue 67 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Add a nested batch i e another complete batch to be executed at this point in the current batch This allows a batch of batches to be specified A nested batch may itself contain further nested batches with no limit to the number of levels of nesting From the Options pull down menu you may e Select the Start batch jobs in foreground option With some operating systems this may considerably increase the speed of calculations 7 2 8 Retrieving calculation details From the File menu on the main toolbar select Open Project Use the File Type selector to request Calculation Details files which have a pj extension and reside in the output directory for the run The calculation details will be loaded and can be inspected This is useful if a run is to be repeated exactly or with modifications If desired the calculation details may be saved as a new project file Calculation details may also be retrieved directly from jobs in the Batch List 7 3 Steady calculations These calculations give quick results by ignoring the effects of any turbine dynamics and wind turbulence They are thus particularly useful at the preliminary design stage e Aerodynamic information
78. del and enter the following parameters Free teeter angle The teeter restraint only start to act when this teeter angle is exceeded Spring preload The torque required to start moving the teeter restraint Spring stiffness The rotational stiffness of the teeter restraint Teeter damping The rotational damping of the teeter restraint Click Special if a client specific teeter restraint model has been provided by arrangement with Garrad Hassan and enter the appropriate parameters See also Calculation options 4 4 Defining the tower Click the Tower button on the toolbar to define the tower characteristics The tower diameter is specified as a function of height The mass and stiffness distributions are also required if tower vibration is to be modelled It is also possible to specify the mass and stiffness properties of the foundation as this can influence the tower vibrational modes significantly 4 4 1 Tower The tower is modelled by defining its characteristics at a number of stations from the tower base to the tower top Tower properties must be defined for at least two tower stations the tower base and tower top although if tower vibrations are to be modelled a minimum of 5 stations is recommended in order to achieve a reasonable degree of accuracy Check the Tower geometry check box to define the tower dimensions These are used to calculate the tower shadow and windage loads Click the
79. demand muct be specified This may be Passive Ist 2nd or higher order models are provided or Active Click Define to specify the appropriate parameters In the Active case a PID controller on pitch rate error generates an actuator torque demand Pitch position limits hardware pitch actuator hard stops must be specified in the case of pitch rate demand input otherwise they are optional Pitch rate limits hardware any actuator rate limits may be specified if required Actuator blade pitching inertia and pitch bearing details For passive actuator models this information is optional and is only used to generate additional calculation outputs such as the pitch bearing friction and pitching inertia note that this varies with blade bending If Actuator details are supplied for the case of passive response to pitch rate demand then the response will be affected by the acceleration limits calculated from the actuator torque limits the applied pitching moment and any bearing friction This is a useful model for hydraulic actuation systems where the flow rate to the cylinder is controlled by a proportional valve The gearbox ratio and torque limits will need to be calculated by treating the linear actuator and pitch linkage as if it were a rotational actuator This model can also be used to give a simplified representation of electrical actuators If Active response to pitch rate demand is specified then the actuator
80. details may not be changed Turbulent wind generation Turbulence details may not be changed Steady calculations and simulations Turbine details may not be changed other calculation details may be changed Post processing calculations Calculation details and input data may not be changed Saving project files Not allowed Writing reports Not allowed but a sample report may be viewed Graphics viewing calculation results Unrestricted When running a calculation a message box warns that the appropriate demo data will be used for the calculation APPENDIX D Bladed Educational Bladed Educational is available solely for academic purposes Certain features of the full code are not available in this version The following restrictions apply to the educational version Turbine e The number of blade radial stations is limited to 10 maximum e The number of tower stations is limited to 5 maximum e The pitch actuator model is fixed to a first order lag response with 0 3s time constant No other pitch actuator models are allowed e The external controller facility is not available Environment e Simulation periods are limited to 60s maximum e The seed used to initialise the random number generators used to synthesise wind turbulence and wave time series is fixed e Only the longitudinal component of wind turbulence can be used in simulations The other components can be synthesised but will be ignored in simulations 115 of 116
81. e These screens are also accessible via the Toolbar Icons described below 3 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Calculation this menu allows particular calculations to be carried out See also the Calculation icon on the main toolbar described below It also allows unwanted calculation results to be deleted Batch this is used to control batch processing of multiple runs Reports This menu also offers the possibility to write a project report or a calculation report to append graphs to a report and to edit or print existing reports It also gives a choice of report format which may be ASCII or Microsoft Word Tools Copy results allows calculation results to be copied from one location to another In doing so the results can be converted between binary and ascii formats if required There is also a facility to Delete results Compare Projects allows two project and or calculation details files to be compared and can generate a detailed report of the differences There is also a facility for configuring the current printer and to specify user preferences for certain option settings Windows switches between any of the currently open windows and gives access to the turbine summary information window Help activates the on line Help facility which contains detailed information on Bladed and how to use it It also gives on line access to the Bladed User and Theory manuals and to a
82. e Batch List From the Batch pull down menu you may Change to another batch queue in a different directory Start the batch run Abort the entire batch run Clear the Batch List From the Jobs pull down menu you may Select all jobs in the queue Enable disable or reset selected jobs Delete selected jobs Run the selected job Abort the job currently running View any warning or error messages from completed jobs View the results of completed jobs From the Edit pull down menu you may Load the calculation details for a selected job If this is a nested batch see below the nested batch will be opened in the batch window Import particular details from a project file or calculation details file into the currently selected job s You will be prompted for the file to import from and asked whether to overwrite the selected batch jobs or create new ones Resubmit the selected job for example after loading the calculation details and editing them Redirect the output of the currently selected job s If more than one job is selected you will have the option of respecifying the output individually or simply maintaining the entire directory structure and run names but specifying a new root directory Create batch jobs from existing calculation details You may choose to import a single calculation into the batch queue or all calculations in a given directory together with subdirectories if desired Copy the selecte
83. e all data is written the controller writes a zero to record 1 to tell the simulation that it is ready If the controller decides to abort the simulation it should write 1 to record 1 and write an appropriate message to discon swp as described in Appendix A 4 Controller returns to step 2 In step 2 the controller waits until record 1 becomes non zero It is important that the controller closes and re opens discon swp every time around the loop otherwise the contents of the file as represented in the disk cache may not have been updated 5 8 2 Writing a user defined controller as a dynamic link library A dynamic link library provides faster and more reliable communications between the controller and the Bladed simulation and is recommended The interface to Bladed is also simpler to write When the simulation starts up the controller DLL file is first copied into the directory where Bladed is installed and renamed discon dll When discon dll is first called the Bladed directory is the current directory The controller is written as a subroutine or procedure The DLL export name of the procedure must evaluate to DISCON note this name must be in upper case Depending on the language system being used it may be necessary to define this by means of an alias The procedure does not generate a return value It has five arguments as follows the names given here are arbitrary and are given purely for ease of reference within this manual
84. e material properties as follows Fatigue model e S N curve Select either the log log or the look up table option The fatigue properties are then entered as follows If Log log relationship is selected enter the inverse slope m and intercept c of the S N curve such that the stress range S giving N cycles to failure is given by log S log c 1 m log N 89 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL If Look up table is selected click the define fatigue data look up table button for a pop up window Use Add or Insert to add points to the look up table and enter the stress values and the corresponding number of cycles to failure by double clicking on the appropriate table entries The stress entries must be monotonically decreasing with the corresponding cycles to failure monotonically increasing e Goodman correction Use the check box to enable the Goodman correction if required If required enter the ultimate strength of the material as a stress If a stress history rather than a previously generated rainflow cycle count is to be processed enter the following data which is required for the cycle counting e Minimum value the start of the stress distribution should be less than the minimum stress e Maximum value the end of the stress distribution should be greater than the maximum stress e Number of bins suggest 20 A higher number maximum 128 will give finer resolution
85. e run s and variable s to be changed This provides a useful and flexible way of storing and re using a particular graph configuration for different sets of results 100 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 9 12 Multiple Plotting and Tabulation Click the Multiple Plots button to bring up the Multiple Plotting screen This feature allows a graph configuration file to be used as a template for a graph or table with the variable in the graph or table being replaced from lists of variables and runs Clicking the Start button will start the series of plots in the order specified by the sequence control This facility is only available to users with the Advanced Post Processing module The graphs and tables may be viewed on screen and or sent directly to a report 9 12 1 Graph configurations Add one or more graph configurations to the list specifying whether any of the runs and or variables defined in the graph configuration are to be replaced from the lists below 9 12 2 Replacing variables If any variables in the graph configuration s are to be replaced they will be replaced by each item in the Variables list in turn Add any desired variables to the list or use Add Set to process complete sets of a specific type of graph or table Clicking on the Add Set button will bring up a choice of the type of set required All the data in a particular run that is part of the specified set will then be pro
86. e system for tower top motion is the same as for the yaw bearing 82 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 7 20 Specifying calculation options A number of machine and wind features once defined are available as options which can be switched on or off in some of the steady state calculations and simulations Click the Show Options button in the bottom left corner of the Calculations screen to display the options Initially all options are switched on by default but if any are switched off for a given calculation the setting will be remembered An option displaying a yellow or red light will not be used even if selected see Section 7 2 3 The options available are Energy losses Drive train flexibility Drive train mounting flexibility Teeter restraint Teeter motion see hub Blade modes see vibrational modes Tower modes see vibrational modes Passive yaw motion Prescribed yaw manoeuvre Imbalances and pitch failures Load safety factors Gravity loads See also safety factors Inertial loads See also safety factors Nacelle and tower windage loads Tower shadow Wind shear Upwind turbine wake 4 6 2 5 17 2 7 17 83 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 8 POST PROCESSING Bladed provides an integral post processi
87. e to display all the required data items in the box below Double clicking on any data item which is undefined opens the appropriate window so that the required data can be defined 7 2 4 Specifying outputs Some of the wind turbine calculations can potentially generate large quantities of results and in many cases only a few of these will actually be needed Click the Outputs button on the calculation screen to specify which of the available outputs will be generated 65 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 7 2 5 Calculation parameters Click the Calculation parameters button on the calculation screen to change or define the specific parameters required to define the selected calculation The following additional data may also be defined Physical constants to define air density and viscosity and gravitational acceleration Aerodynamics control to define the aerodynamic modelling parameters Simulation control to define how a simulation will proceed Safety factors to be applied to certain loads Imbalances and pitch failures to specify mass and aerodynamic imbalances and pitch system failures 7 2 6 Executing a calculation Click on Run Now to carry out the selected calculation immediately or Run in Batch to store the calculation for later execution by the batch facility Except for certain calculations
88. ect button to define the signal to be processed button to define the signal to be processed If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results will be accumulated over the turbine lifetime For each variable to be processed enter the following data e Minimum value the start of the distribution should be less than the signal minimum e Maximum value the end of the distribution should be greater than the signal maximum e Number of bins suggest 20 A higher number maximum 144 will give finer resolution provided there is sufficient data 88 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 8 10 Rainflow cycle counting This calculation generates the rainflow cycle count for a stress history A suitable stress history can be generated from the relevant loads using the Channel_combination calculation Click the Select button to define the stress signal to be processed button to define the signal to be processed If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results will be accumulated over the turbine lifetime For each variable to be processed enter the following data e Minimum value the start of the stress distri
89. ected by double clicking or pressing OK The data for that aerofoil may then be edited To add a new angle of attack enter it in the coefficients window and press Add To modify a datapoint click on it and press Edit to make it appear in the coefficients window where it can be edited To remove a datapoint click on it and press Delete When editing is finished click the Save button To save it as a new aerofoil dataset modify the General data as appropriate change or insert any comments in the Comments box change the Name as required and then click Save The Copy button may also be used to transfer aerofoil data via the clipboard to another application 3 7 5 Removing a dataset Click the Delete dataset button 3 7 6 Viewing aerofoil data graphically Select the view required change the range of angles of attack if desired and click View Data The graph may be printed or saved as a Metafile or copied to the clipboard for subsequent inclusion in a report 3 8 Format of ASCII aerofoil files In order to import aerofoil data into the database generate an ASCII file containing the data using the format described here This consists of a header section describing the aerofoil and the conditions to which the data relate followed by a table of the lift drag and optionally pitch moment coefficients against angle of attack and terminated by a label which marks the end of the dataset Apart from comment line s the header lines each
90. ed spikes on some variables which are not reflected in related variables If there is any doubt repeat a simulation with a different tolerance to see if the results are significantly affected e Minimum time step the simulation uses a 4 5th order Runge Kutta variable time step method The time step will be reduced automatically if the specified tolerance is exceeded until this minimum value is reached A very small value for the minimum time step is recommended such as 10 s to ensure that the accuracy of simulation is not constrained by this In special cases increasing the minimum time step may speed up the simulation with little loss of accuracy but it is advisable to check that the results are not significantly altered by doing this This situation may arise for example with a dynamic mode which is inactive because it is heavily damped It may be better to remove the mode completely e Maximum time step This should normally be the same as the Output time step although a smaller value might be useful in some cases if the output time step is particularly long e Initial time step The recommended value is zero the minimum time step will in fact be used A value larger than the minimum time step will speed up the initialisation of the simulation but there is a risk of numerical problems if too large a value is used 7 14 Dynamic power curve calculation The Dynamic power curve calculation carries out a series of simulations at different w
91. egrees from the horizontal e Depth at breaking waves the distance between mean water level and the sea bed at the location of the breaking wave Period of breaking waves e Direction from North the bearing from which the current arrives at the tower The near shore current is assumed to flow parallel to the shore line 62 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 7 EXECUTING WIND TURBINE CALCULATIONS This section describes how to set up the calculation parameters which define how a particular calculation will be carried out and how to carry out the calculations themselves Section 7 1 describes the modal analysis calculation which is used to determine the frequencies and mode shapes of the blade and tower vibration modes The remaining sections describe the various wind turbine performance and loading calculations themselves 7 1 Modal analysis A modal representation of the blade and tower structural dynamics is used in Bladed A modal analysis calculation is performed first to compute the frequencies and mode shapes which are needed for any subsequent calculations which are to take account of blade and or tower deflections or vibrations The steady deflections may be of interest for calculating the Steady operational loads or the Steady parked loads and the vibration dynamics may be used in any of the simulations The modal analysis calculates uncoupled rotor and tower
92. eld length should be U T Turbine diameter It may be longer than this although in this case the mean wind speed and turbulence intensity for the simulation may not match the values selected as they apply only if the whole file is used e Mean wind speed the mean wind speed for the turbulent wind at the reference height If this does not match the wind speed for which the turbulence characteristics were defined the turbulence field will be scaled appropriately However since the dimensionless characteristics of turbulence are not quite invariant with wind speed this scaling is not strictly valid 54 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Height at which speed is defined the reference height to which the Mean wind speed applies unless Refer wind speed to hub height has been selected If wind shear is defined the mean wind speed at any other height will be different e Turbulence intensity the standard deviation of turbulent wind speed variations as a fraction of the mean wind speed If using a three component wind field specify the turbulence intensity for each component e Wind direction measured clockwise from North see wind direction e Flow inclination for non horizontal wind flows e g on the side of a hill A positive value indicates a rising wind For the Height of turbulent wind field select one of the following options These do not affect the mean wind speed at any heigh
93. elle width e Nacelle drag coefficient And the drag force is then calculated based on the projected nacelle area perpendicular to the wind direction at any time Aerofoil model if the lift and drag forces on the nacelle are known as a function of yaw angle specify e Nacelle length e Nacelle height e The position of the upwind end of the nacelle relative to the tower axis and e Select an aerofoil from the database which has been constructed to give the correct variation of lift and drag with angle of attack yaw angle The nacelle length will be used as the aerofoil chord and the aerofoil area will be the product of length and height Check the Mass checkbox to define the nacelle mass characteristics required for dynamic calculations This includes the nacelle structure and all the machinery within it It does not include the rotor blades and hub If the Direct Drive option is selected the mass of the generator is also excluded Enter the following e Mass on tower top e Centre of mass position see diagram e Moment of inertia about tower axis Marcelle centre of raars T i F aa Top of tower Diagram showing positive directions for centre of mass position relative to the top of the tower showing wind direction during normal running Note The Turbine Information window shows the total masses and inertias of all turbine components whose mass characteristics are defined Use the Windows pull down menu on t
94. end may be added This is useful for plots showing more than one dataset as it allows the different datasets to be identified Click the Legends and line styles button to edit the default legend captions and to specify where the legend is to appear on the graph One of five line thicknesses may be selected for each line of the graph Clicking on a legend entry with the Shift button depressed will freeze it so that it will no longer be updated automatically as channel selections and units are changed A second shift click will unfreeze the entry so that it will be automatically updated 99 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 9 8 Cross plots Two dimensional graphs can be presented as cross plots if two or more channels with compatible independent variables have been selected Use the X axis selector to define which channel is to be plotted along the X axis The other channels will then be plotted against this one 9 9 Tabular output of results Click the Tabulate button on the Graph Parameters screen to tabulate the current graph data A dialogue box allows you to select the format Screen the data can be viewed on the screen ASCII to save the table as tab delimited ASCII text Excel to save the table as a Microsoft Excel workbook You must have Microsoft Excel installed Word the default to save the table in a Microsoft Word document you must have Microsoft Word installed When viewed
95. endent you will get a 3D graph 8 20 2 Messages and further information 96 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL The View Messages button displays any warning or error messages generated during the run In a few cases some additional information is available by clicking the View Info button 8 20 3 Deleting information Buttons are available on the data channel selector to permanently delete a data group or an entire run 97 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 9 GRAPHICAL DATA VIEW FACILITY Click the Data view icon on the toolbar to open the Graph Parameters screen First click the selection button for either a two dimensional or three dimensional graph Then click the Channel 1 button to select the data you wish to view see Data channel selection for details of selecting data for two or three dimensional graphs A Special graph type is available for results of the Ultimate Load Cases calculation If required make any changes to the format of the graph on the Graph Parameters screen Then click the View Graph button to display the graph The graph can then be printed if desired using the Print button or saved to a metafile or bitmap using the Save button The metafile can then be inserted into a report Alternatively copy the graph to the clipboard using the Copy Metafile or Copy Bitmap button The selected graph data may also be
96. eparation position time constant This is a dimensionless time constant given in terms of the time taken to travel half a chord It defines the lag in the movement of the separation point due to unsteady pressure and boundary layer response It should have a negative value and 3 0 is recommended e Starting radius This is the radial position given as a percentage outboard of which the dynamic stall model will be used This allows the use of data on the inboard blade sections that has been corrected for the effects of three dimensional flow This type of data should not be used in combination with the dynamic stall model which has been developed for use with two dimensional aerofoil data 7 16 Physical constants Use the Physical constants screen see Calculation parameters to define the following general physical constants e Air density e Air viscosity dynamic e Gravitational acceleration g e Density of water only required for offshore turbines 7 17 Safety factors Use the Safety factors screen see Calculation parameters to define additional factors to be applied to the blade hub and tower loads when they are output Each load may have several components and different safety factors may be applied to each as follows e Aerodynamic loads this safety factor will multiply the aerodynamic component of output loads e Gravity loads this safety factor will multiply the gravitational component of output lo
97. er a description for the file To load the details of an previous Channel Combination calculation click Import details and select whether to import the channel combination details the list of load cases or both Click Channels and Load Cases to edit or define the channel combination details and the list of load cases Up to 18 input signals can be combined to generate anything up to 50 output signals Click New gt gt to define a new output signal and enter a description for it Select one of the available units for the signal if appropriate For each output variable click Add Variable to select the required input variables Specify any factor offset and other unary operators to be applied to each input signal before it is combined with the other input signals The Factor is applied first then the Offset then any Unary operators are applied If several unary operators are specified they must be separated by a vertical bar They will be applied in order starting from the right most Allowed operators are SIN sine of a value in radians COS cosine of a value in radians ABS absolute value SQRT square root 91 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL INV reciprocal n Add a number n n Subtract n xn Multiply by n n Divide by n n Raise to the power n where n is a real number which may be negative For example SIN x 3 2 0 2 ABS 0 1 would calculate sin 3 2 x 0 1
98. erforming calculations 7 2 5 Viewing results 7 2 6 Compiling reports 8 2 7 User preferences 8 2 8 Context sensitive help 9 3 DEFINING THE TURBINE BLADES 10 3 1 Choosing blade stations 11 3 2 Blade geometry 11 3 2 1 The blade reference plane 12 3 3 Blade mass distribution 12 3 3 1 Distributed mass 12 3 3 2 Point masses 12 3 3 3 Vibration dampers 13 3 3 4 Blade icing 13 3 4 Blade stiffness distribution 13 3 5 Flap Twist Coupling 14 3 6 Aerofoil sections 14 3 7 Aerofoil datasets 15 3 7 1 Defining aerofoil datasets 15 3 7 2 Importing a dataset 15 3 7 3 Adding a new dataset manually or via the clipboard 15 3 7 4 Editing an existing dataset 16 3 7 5 Removing a dataset 16 3 7 6 Viewing aerofoil data graphically 16 3 8 Format of ASCII aerofoil files 16 3 9 Defining normal aerofoil sections 18 3 10 Defining aileron sections 18 4 DEFINING THE REST OF THE TURBINE 20 4 1 Defining the rotor 20 4 2 Defining the hub 21 4 3 Teeter restraint 22 i Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 44 Defining the tower 22 4 4 1 Tower 22 4 4 2 Flanges and point masses 23 4 4 3 Environment 23 4 4 4 Foundation 24 4 5 Defining the power train 24 4 6 Transmission 24 4 6 1 Locked speed model 24 4 6 2 Dynamic model 25 4 7 Drive train mountings 25 4 8 Generator 26 4 8 1 Induction generator 26 4 8 2 Variable speed generator 27 4 8 3 Variable slip generator 28 4 9 Energy losses 28 4 9 1 Mechanical losses 28 4 9 2 Electr
99. erties The graph is updated as soon as any new values are assigned giving an instant indication if faulty values are entered Controls are provided to change the format of stiffness graphs and to print the graph or save it to a metafile which can subsequently be incorporated into a report Click the Add button to add a new blade station Stations are automatically sorted by radial position To highlight a station click on the station number or double click on a graph point Click Delete to remove a highlighted station To enter or edit data highlight the data item by clicking on it or by moving to it using the arrow keys and then pressing the Return key Press Escape to restore the previous value Highlight a block of cells by dragging the mouse These cells may be copied to the clipboard or the contents of the clipboard may be pasted in In this way data from a spreadsheet or a tab delimited ASCII file may be directly pasted in Click Undo to reverse a paste operation Note that the Moving Fixed and Foil Section entries may not be pasted in Click on Moving Fixed to specify which parts of the blade are pitch or aileron controlled Click on Foil Section to select an aerofoil section or to define a new section If a sharp discontinuity in blade characteristics is re uired split a blade station into an rp discontinuity q p inboard and an outboard station at the same radial position This is especially useful to mark the discont
100. ether define the nacelle yaw angle This may change during a simulation if any yaw control is specified i e either passive yaw or a yaw manoeuvre Note that the yaw angle can also be defined explicitly for the steady parked loads calculation Positive sense for wind direction N and nacelle onentation nacelle onentation Upwind Downwind Default oe 57 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 6 10 Generating turbulent wind fields In order to run a simulation which uses a 3 dimensional turbulent wind field a suitable wind field must first be generated Once generated these turbulent wind fields are stored so that they can be used for future simulations Turbulent wind fields contain time histories of wind speed at each of a number of points on a rectangular grid covering the turbine rotor swept area The time history at each point will have spectral characteristics conforming to either the von Karman or the Kaimal model of wind turbulence The time histories at any two points in the rotor plane will be correlated with each other in accordance with an appropriate model of the lateral and vertical coherence characteristics of atmospheric turbulence Linear interpolation is used between grid points as well as between successive time points To generate a new wind field first define the turbulence characteristics and then generate the wind field as described below 6 10 1 Def
101. ey are ignored if the rotor has no aerodynamic control surfaces 5 13 Normal stop sequence Normal stops use aerodynamic braking and or the shaft brake to stop the rotor from the normal running condition For simulations of normal stops click the Normal stop button on the Control screen To use the built in logic for normal stops specify the following parameters e Pitch rate the constant pitch change rate used during the stop sequence e Maximum pitch the final pitch angle If the Pitch rate is negative the Maximum pitch should actually be the most negative pitch angle The initial pitch angle will depend on the running conditions before the stop occurs e Rotor speed for cut in of shaft brake when the rotor has slowed down to this value the shaft brake is applied to bring the rotor to rest The normal stop begins at the Time to begin a stop specified in Simulation control 46 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Alternatively click Defined by external controller to use your own normal stop logic Note that the Time to begin a stop does not apply in this case Notes 1 Pitch angles and rates apply also to aileron flap airbrake deployment angles They are ignored if the rotor has no aerodynamic control surfaces 2 User defined supervisory control may also be defined in an external controller 5 14 Emergency stop sequence Emergency stops use aerodynamic br
102. f desired select the option to scale the wind speed distribution by a series of factors the energy yield will then be calculated as a function of annual mean wind speed while retaining the shape of the wind speed distribution In this case enter e Starting annual mean wind Energy yield will be speed calculated for each e End annual mean wind speed mean wind speed in this e Annual mean wind speed step range 8 14 Channel Combination Use this calculation to combine and scale a number of signals This is particularly useful for generating a stress history for a particular point in the wind turbine structure by expressing it as a linear combination of the various loads acting on the component The stress history can then be used to calculate fatigue damage The scale factors used for the linear combination should be such that the resulting signal is in the same stress units as are assumed in the fatigue damage calculation 8 14 1 Multiple processing option If Combine variables across different load cases is not selected a calculation can be set up in which up to 18 signals from a particular load case may be combined to generate one or more combined signals attached to that load case A list of load cases may be specified so that the same set of channel combinations is repeated for each of the load cases First define the Combined Signal File No from 1 to 260 up to 260 combined signal files may be generated for any load case and ent
103. f that load case Then choose either automatic or manual selection of data Automatic selection is usually adequate but if entered manually the parameter required is e Number of bins the number of azimuthal bins to be used in the calculation minimum 4 maximum 144 More bins will generally give a more accurate result but do not choose more bins than the number of signal samples in one revolution of the rotor 8 4 Extreme predictions Use this calculation to estimate lifetime extreme loads from a sample time history Click the Select buttons to define the signal to be processed and the signal representing rotor azimuth If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results for each load case will then be stored as additional outputs of that load case Then enter the following information 85 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Time spent at specified condition the total amount of time during the turbine lifetime for which the conditions of the sample time history are considered representative e Number of points per segment power of 2 maximum 4096 e Percentage overlap See Section 8 5 1 e Window select e Remove trends check box Then choose either automatic or manual selection of data Automatic selection is usually adequate but if entered manually
104. facility for upgrading the dongle or security device by entering an appropriate password 2 1 2 Toolbar icons Beneath the pull down menus on the toolbar are the Toolbar Icons Clicking on any one of these opens up the corresponding screen as follows Blades to define the blade properties Aerofoil sections to access a database of aerofoil section data Rotor to define the properties of the rotor and overall turbine configuration Tower to define the tower properties Power Train to define the drive train generator energy losses and electrical network Nacelle to define the nacelle geometry and mass Control to define both power production and supervisory control systems The wind input to define the wind speed and direction including spatial and temporal variations Waves and currents to define the sea state for offshore turbines Modal analysis to specify the modal analysis of blade and tower vibrations Calculations to select specify and execute any particular calculation Data View to view graphs or generate tables of results Analyse to specify post processing of results 6 12 6 13 2 1 3 The calculation window The Calculations window lists all the available calculations any one of which may be selected by clicking on it with the mouse Next to each calculation is an indicator light If this is green the calculation may be performed A red light indicates
105. fined below e Output time step this is the time interval at which the output variables are sampled For individual simulations these samples are stored in the output files For the dynamic power curve calculation these samples are used to calculate the statistics for each individual simulation i e each wind speed e Time to start writing output Some simulations may start with a small transient if the initial conditions are not calculated to sufficient accuracy In this case it may be desirable to ignore the first part of the simulation until the transient has settled This parameter specifies the length of time to ignore at the start of the simulation before output samples start to be taken e Simulation end time This parameter gives the maximum time for which the individual simulation will run Normal and emergency stop simulations may end earlier if the rotor has stopped and any extra time has elapsed e Time to begin a stop for normal and emergency stop simulations this is the length of time for which normal running continues before the built in stop logic is initiated e Extra simulation time after stopping for normal and emergency stop simulations this is the length of time for which the simulation continues after the rotor has come to rest e Start time for turbulent wind this applies to simulations which use a turbulent wind input It is the time into the turbulence time history at which the simulation begins Specif
106. from the input signal x Then select how the resulting input signals are to be combined This may be by e addition e squaring and adding then taking the square root of the result or e multiplying Finally click Load Cases to set up a list of load cases for which the resulting set of channel combinations will be repeated 8 14 2 Single channel combinations Alternatively select Combine variables across different load cases to generate a new variable not attached to any existing load case You will then be asked for a directory and run name for the output when you start the run In this case click the numbered channel selection buttons to define up to six signals to be combined The signals may be from different runs or load cases if desired For each signal enter a scale factor and an offset Enter a description for the combined signal and choose units if appropriate The scale factors a are applied before the offsets b i e the result of the calculation can be expressed as y a x b if Simple Addition is selected If Square Add Square Root is selected the result is y JZ lax b Enter a description for the combined signal and select one of the available units for the combined signal if appropriate 8 15 Multiple Processing A number of post processing calculations allow a whole list of variables to be processed across a whole list of load cases If appropriate the results are accumulated over t
107. full inflow calculation will be carried out Between these two values the inflow calculation is phased in gradually Parameters applicable to dynamic calculations only e Wake models The equilibrium wake model recalculates equilibrium inflow velocities at every instant in time The frozen wake model calculates equilibrium inflow velocities at the start of the simulation but then maintains these values for the rest of the simulation This results in a fast calculation and may be sufficiently accurate for simulations at near zero yaw angles with a relatively uniform wind field and little variation in wind speed or rotor speed The dynamic inflow model recalculates the inflow factors at intervals and uses an induction lag This model is recommended for simulations in which the wake cannot considered to be frozen or unchanging and it results in faster calculations than the equilibrium wake model Dynamic wake time step specify the time interval at which the inflow is recalculated To avoid slowing simulations unnecessarily it is recommended to 76 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL use a time step equal to the simulation output timestep or the external controller timestep As the wake only changes slowly the precise value selected is not critical e Stall hysteresis The check box allows the Beddoes stall hysteresis model to be selected which allows dynamic stall effects to be modelled Enter the e S
108. fy any shaft torsion as the simulations will then run faster The dynamic drive train model may be used in combination with flexible mountings Note including drive train flexibility may reduce the speed of simulations 4 7 Drive train mountings The Power Train button on the toolbar also allows the drive train mountings to be specified If desired torsional flexibility may be specified either in the gearbox mounting or between the pallet or bedplate and the tower top This option is only allowed if the dynamic drive train model is specified In either case specify the following parameters e The torsional stiffness of the mounting e The damping of the mounting e The moment of inertia of the moving components about the low speed shaft axis In the case of a flexible gearbox mounting this is the moment of inertia of the gearbox casing In the case of a flexible pallet mounting it is the moment of inertia of the gearbox casing the generator stator the moving pallet and any other components rigidly fixed to it 25 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL If either form of mounting is specified the direction of rotation of the generator shaft will affect some of the loads If the low speed and high speed shafts rotate in opposite directions specify a negative gearbox ratio in the drive train model Flexible mountings introduce a high frequency mode which is liable to result in much
109. g a dataset Aerofoil datasets may be imported from an ASCII file of aerofoil data by clicking the Import button see Section 3 8 for the required format of the ASCII file A standard file selection screen appears Select the drive directory and file where the data is stored If the identifier specified in the file duplicates one which exists in the database you will be prompted for a different identifier to be used 3 7 3 Adding a new dataset manually or via the clipboard Click the New button fill in the General data to characterise the aerofoil dataset add comments as required and give the dataset an appropriate identifier in the Name box The aerofoil data itself may be pasted in from the clipboard by clicking the Paste button The data should be copied from a spreadsheet or tab delimited file and should consist of three or four columns angle of attack in degrees Lift coefficient Drag coefficient and Pitching moment coefficient if included 15 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Alternatively type the data for each angle of attack in the coefficients box clicking Add after each one Then press Save New datasets may also be created by editing existing ones as described below 3 7 4 Editing an existing dataset Click the Load button to list the names of all currently available datasets Clicking one of these names displays the main characteristics of that dataset which can then be sel
110. h angle for each blade specify the error in pitch or aileron airbrake angle see Blade geometry e Error in blade azimuth for each blade specify the error in azimuthal position for each blade Note this will result in an additional contribution to the mass imbalance e Pitch failure mode for each blade specify whether the pitch mechanism has Failed is operating correctly Moving or is set to fail at the Time for pitch failure specified above In the latter case the blade pitch will freeze at its current value at that time e Pitch of failed blade for each blade where the pitch mechanism is Failed specify the angle at which the pitch is stuck applies also to ailerons airbrakes 7 19 Controlling the calculation outputs A large amount of output is potentially available from some of the steady state calculations and simulations Click the Outputs button on the Calculations screen to define which of these outputs are required The outputs are grouped into blade tower and other outputs Aerodynamic information Performance coefficients and the Power curve calculations are unaffected as they produce a pre defined set of outputs 7 19 1 Blade outputs Click Blade outputs on the output specification screen Blade outputs include aerodynamic information including distributed aerodynamic loadings blade loads and deflections For each of these categories the information may be generated at any or all of the blade stations
111. have a unique identifier If Load Case Groups have been defined the identifier will attempt to set itself to a sensible default which the user is free to change if required For each variable specify whether its maximum and minimum are to be found An additional feature available to users with the Advanced Post Processing module is to combine blade loads across all blades With this option the maximum and minimum loads across all blades will be reported The output from this calculation consists of an ASCII text file with many rows and columns The file name will be lt directory gt lt run name gt mx where the directory and run name are 93 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL entered at the time of running the calculation The file is suitable for importing directly into a spreadsheet and can also be tabulated using the Multiple Plots feature For users with the Advanced Post Processing module additional output is available in the form of histogram plots which present comparison between the load cases group A drop down list on the Load Cases tab allows the desired type of histogram output to be selected You can also use the Ultimate Load Cases calculation to process one or more Ultimate Loads output files and give a graphical presentation of results 8 17 Ultimate Load Cases This calculation generates a list of maxima and minima of loads and the load cases in which they occu
112. he following information First order passive The pitch actuator is modelled as a first order lag Enter the time constant or Second order passive Enter the natural frequency and the fraction of critical damping for the second order transfer function or Other passive Enter the required coefficients for powers of the Laplace variable s in the transfer function numerator and denominator The numerator must have lower order than the denominator 5 10 2 PID parameters Click the appropriate Define button and enter the following information for the closed loop PID controller which generates either a pitch rate demand output signal from a pitch position error input signal or a torque demand output signal from a pitch rate error input signal 44 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Then if the input error signal is x Xa Xm Xa is the demand and Xm the measured or feedback signal and the output demand signal is y the Laplace representation of the PID controller is K K y K ese Oe s 1 sT Enter the following parameters Input filter time constant a 1 order pre filter which smooths step changes in demand coming from a discrete controller Specify zero for no pre filter Proportional gain K Integral gain Ki Differential gain Ka Applied to The differential term may apply to the feedback x Xm demand x Xa or error x x term see below Specify x
113. he main toolbar to open this window 30 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 CONTROL SYSTEMS Click the Control icon on the toolbar to open the Control Systems screen This allows definition of the power production control characteristics as well as supervisory control functions Power production control Power production control models are available for pitch or stall regulated fixed or variable speed turbines Select one of the following options 1 Fixed speed stall regulated the induction generator model should be selected 2 Fixed speed pitch regulated the induction generator model and a pitch or aileron controlled rotor should be selected 3 Variable speed stall regulated the variable speed generator model should be selected 4 Variable speed pitch regulated the variable speed or variable slip generator model should be selected and a pitch or aileron controlled rotor See Generator Drive traint Defining the rotor The steady state parameters define the operating envelope of the turbine and are required for calculation of the steady power curve and steady operational loads Click on Controller Dynamics to define additional parameters which model the dynamic action of the controller such as controller gains and transducer and actuator time constants The different power production control models are described in Sections
114. he turbine lifetime or any other desired period assuming a particular wind speed distribution and a frequency of occurrence for transient events Otherwise the results are stored as additional outputs for each load case 92 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL In the window for the required post processing calculation click Multiple Channels to bring up the Multiple Processing window Use the Add Load Case and Add Variable buttons to build up the required lists of load cases and variables Add Many Load Cases allows all the calculations in a selected directory including subdirectories if desired to be added in one go In most cases multiple variables can be selected in one go by dragging over a number of variables or holding down the Control key and clicking on the required variables It is important to ensure that the output specifications for all the load cases are the same i e the same outputs and the same blade and tower stations have been requested If available in the Load Cases window enter the Occurrences per Year for transient load cases such as stops and starts or the wind speed bin or number of hours per year which the load case is deemed to represent in the case of stationary load cases click the lt gt button to select either wind speed bins or number of hours per year It is possible to treat a stationary load case as transient or vice versa by clicking on the S or
115. iStatus rMeasuredSpeed rMeasuredPitch amp rPitchDemand cOutName cMessage ENDIF Return strings DO I 1 NINT avrSwap 64 avcOutname I iOutName I same as cOutName I by EQUIVALENCE ENDDO DO I 1 MIN 256 NINT avrSwap 49 avcMsg I iMessage I same as cMessage I by EQUIVALENCE ENDDO RETURN END 113 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL B 3 Simple example of EXE code written in FORTRAN 90 MPLICIT NONE LOGICAL 10K NTEGER iERROR iUNIT iFail iSTATUS iStarted REAL rTime rPitchDemand rMeasuredPitch rMeasuredSpeed First open the swap file L UNIT 99 OPEN L_UNIT FILE DISCON SWP ACCESS DIRECT FORM UNFORMATTED RECL 4 amp ACTION READWRITE DENYNONE IOSTAT iERROR F iERROR NE O STOP Could not open swap file Set initialisation flag iStarted 0 Write zero to record 1 WRITE iUNIT REC 1 IOSTAT iERROR 0 CLOSE iUNIT IF iERROR NE 0O STOP Could not write to swap file Wait for Bladed 10K TRUE DO WHILE 10K OPEN iUNIT FILE DISCON SWP ACCESS DIRECT FORM UNFORMATTED RECL 4 amp ACTION READWRITE DENYNONE IOSTAT iERROR IF iERROR NE 0O STOP Could not re open swap file READ iUNIT REC 1 IOSTAT iERROR iSTATUS IF iERROR NE 0O STOP Could not read status from swap file IF iSTATUS EQ 1 THEN End of simulation 10K FALSE LSEIF iSTATUS EQ 0 THEN Still waiting CALL SLEEPQQ 1 W
116. ial span pitch or aileron controlled rotors or in the assisted stall case Gain scheduling is unlikely to be required for below rated controllers on variable speed turbines For above rated stall regulated variable speed controllers the need for gain scheduling will depend on the stall characteristics 5 7 Variable speed control below rated Select Optimal tip speed ratio or Look up table and proceed as follows 5 7 1 Optimal tip speed ratio Below rated wind speed a variable speed turbine may try to stay at its optimum tip speed ratio wherever possible by changing the rotor speed in proportion to the wind speed This maximises the power coefficient and hence the aerodynamic power available This can be achieved in the steady state by setting the generator torque to be proportional to the square of the rotor or generator speed The Optimal mode gain multiplies the square of the generator speed to give the required generator torque demand It can be calculated as Kou mpR C 2G where Kon Optimal mode gain p air density R rotor radius C power coefficient at desired tip speed ratio G gearbox ratio The torque demand is then given by Qa K p where Q generator torque demand Q measured generator speed Note that energy output may not be maximised by maximising aerodynamic efficiency because the energy losses may also vary with the operating point It may therefore be better to track a slightl
117. ical losses 28 4 10 The Electrical Network 29 4 11 The nacelle 30 5 CONTROL SYSTEMS 31 5 1 Fixed Speed Stall Regulated Control 32 5 2 The fixed speed pitch regulated controller 32 5 2 1 Steady state parameters 32 5 2 2 Dynamic parameters 32 5 3 The variable speed stall regulated controller 33 5 3 1 Steady state parameters 33 5 3 2 Dynamic parameters 33 5 4 The variable speed pitch regulated controller 34 5 4 1 Steady state parameters 34 5 4 2 Dynamic parameters 34 5 5 PI control 35 5 6 Gain scheduling 36 5 7 Variable speed control below rated 37 5 7 1 Optimal tip speed ratio 37 5 7 2 Look up table 38 5 7 3 Other parameters 38 5 7 4 Control in the variable slip case 38 5 8 User defined controllers 39 5 8 1 Writing a user defined controller as an executable program 39 5 8 2 Writing a user defined controller as a dynamic link library 40 5 8 3 Using a user defined controller 41 5 8 4 Signal noise and discretisation 42 5 9 Transducers 42 5 10 The pitch actuator 42 5 10 1 Passive dynamics 44 5 10 2 PID parameters 44 5 11 The shaft brake 45 ii Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 12 Start up sequence 46 5 13 Normal stop sequence 46 5 14 Emergency stop sequence 47 5 15 Idling conditions 47 5 16 Parked conditions 48 5 17 Yaw control 48 5 17 1 Yaw Dynamics 48 5 17 2 Active Yaw 49 6 DEFINING THE ENVIRONMENT 50 6 1 Defining the wind 50 6 2 Wind shear 51 6 3 Tower shadow 51 6 4
118. ich include controller dynamics e Power transducer See transducers A speed transducer may also be defined if time constant desired e Pitch actuator Enter the software rate limits for use in the control algorithm dynamics Click Actuator to specify the pitch actuator details e Control algorithm Choose between PI and Discrete External and click Define to specify the details 32 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 3 The variable speed stall regulated controller Use this control model for a variable speed turbine i e with a variable speed generator which uses the aerodynamic stall characteristics of the rotor to control the power above rated wind speed 5 3 1 Steady state parameters To specify the steady state operating curve supply the following data Torque speed curve below See Variable speed control below rated rated e Demanded shaft power The power set point i e the shaft power required above rated wind speed See Energy losses Section 4 9 e Maximum generator speed Usually the same as the Optimal mode maximum speed but exceptionally a higher value could be used for high wind speed operation 5 3 2 Dynamic parameters This controller varies the generator torque to regulate the speed of the generator and rotor Above rated the power can be controlled by adjusting the speed set point to stall the rotor The follo
119. icking Change configuration 2 8 Context sensitive help For context sensitive help press the F1 key at any time 9 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 3 DEFINING THE TURBINE BLADES This section describes how to construct a model of the wind turbine blades including geometrical mass and stiffness properties as well as the aerodynamic characteristics of the aerofoil sections Click the Blades icon on the toolbar to open the Blade Properties screen Before any calculations can be carried out the user must define the geometry and aerodynamic characteristics of the rotor blades If any dynamic calculations are required check the Mass checkbox to allow the blade mass distribution to be defined If blade flexibility is to be modelled also check the Stiffness checkbox to allow the blade stiffness distribution to be entered If flap twist coupling is to be modelled also check the Flap Twist Coupling checkbox to allow torsional rigidity mass moment of inertia and principal neutral axis for bending to be entered This option is only enabled if both the Mass and Stiffness checkboxes have been checked All these blade properties are defined at a number of stations along the blade although additional point masses may also be defined anywhere on the blade by clicking the Point masses button The Graph button controls the graphical display of blade prop
120. ifference in wind speed between the two sides of the rotor plane The wind speed varies linearly with horizontal distance across the rotor plane e Vertical wind shear defined as the difference in wind speed between the top and bottom of the rotor plane The wind speed varies linearly with height All four transients will be used but if any is not required specify an appropriate start value and a zero amplitude For each transient enter the following information for the variable in question Start value the value of the variable before the start of the transient Amplitude of change the largest range from maximum to minimum during the transient Time to start cycle the time into the simulation at which the transient starts Time period of cycle the duration of the transient Type of cycle Three types of transient are provided as specified by various standards A half wave transient begins with the start value and increases sinusoidally by the amount defined by the Amplitude A full wave transient begins with the start value and changes sinusoidally by the amount defined by the Amplitude in the first half of the time period changing back to the start value by the end of the time period The IEC 2 transient is a more complex shape as described in the Theory Manual 56 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 6 9 Definition of wind direction The default nacelle orientation and the wind direction tog
121. ified wind direction see above refers to the start of the simulation The mean wind direction will be different from this if a transient is added e Start time of transient the time into the simulation at which the transient starts e Duration of transient the duration of the transient from the time it starts to the time it finishes o Type of transient half or full wave see Section 6 8 6 8 Transients Use this option to define sinusoidal wind speed and direction transients such as are defined in certain standards such as for example IEC 1400 1 These transients are superimposed on 55 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL any steady state spatial variations defined by wind shear tower shadow and an upwind turbine wake Click the Wind icon on the toolbar select Time varying wind and choose the Transients option First enter the following data e Reference height at which the wind speed is defined unless Refer wind speed to hub height has been selected If wind shear is defined the wind speed at any other height will be different e Flow inclination for non horizontal wind flows e g on the side of a hill A positive value indicates a rising wind Separate transients may be defined for each of the following variables e Wind speed defined at the reference height e Wind direction measured clockwise from North see wind direction e Horizontal wind shear defined as the d
122. ignals to be processed If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results for each load case will then be stored as additional outputs of that load case Then enter the information required as follows e Number of points per segment power of 2 maximum 4096 e Percentage overlap See Section 8 5 1 e Window select e Remove trends check box 8 7 Probability density This calculation generates the probability distribution of a signal and also for comparison the Gaussian or normal distribution with the same mean and standard deviation Using the Revs at Level option it is also possible to bin the signal based upon a signal other than time In this case the Azimuth signal will also need to be defined If rotor azimuth is selected for this the load level will be binned against the number of revolutions which is useful in gearbox and bearing design Click the Select button to define the signal to be processed If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results will be accumulated over the turbine lifetime 87 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL For each variable to be processed enter the following data e Minimum value the start of the distri
123. in toolbar and select Append Graph Dialogue boxes appear allowing you to select the metafile required and the Word document to which it will be appended The graph may be inserted fully or as a link see Linked a hs Alternatively click Copy Metafile on the graph window to copy the graph to the clipboard and paste it directly into the report Graphs cannot be appended to ASCII reports To append a table of results rather than a graph refer to Section 9 9 10 4 Editing and printing reports An existing report may be edited and printed From the Reports menu on the main toolbar select Edit report or Print report If Edit report is selected and the report format is set to Word Microsoft Word will be opened and any desired editing may be carried out If the report format is ASCII the Windows Notepad editor will be opened 10 5 Linked graphs From the Tools gt Preferences menu on the main toolbar the Insert graphs as links option allows graphics inserted into a Word report using the Reports pull down menu option to be linked to an external metafile The Word document will be smaller but not transportable unless the metafile is moved with it 104 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL APPENDIX A Communication Between Bladed And External Controllers This appendix describes in detail the communication between Bladed and the user s external controller code See also Section 5 8 Appe
124. ind speeds and rotor azimuths defining the operating points There are also vectors containing the steady state values of all inputs states and outputs at each operating point as well as some additional information which may be of use in controller design such as the gearbox ratio number of blades and nominal speed and torque values In the mat file the variable names used are fairly self explanatory except that the state space matrices and the names of the inputs states and outputs are all stored in a structure called SYSTURB The elements of SYSTURB are inputname The names of the input variables character array outputname The names of the output variables character array statename The names of the state variables character array A B C D Arrays of the state space matrices for the different operating points thus A i j k l is the ij element of the A matrix i e row I column j for the k wind speed and the 1 rotor azimuth angle This structure can readily be converted to a Matlab Iti model array using the single Matlab command SYS ss SYSTURB A SYSTURB B SYSTURB C SYSTURB D inputname cellstr SYSTURB inputname outputname cellstr SYSTURB outputname statename cellstr SYSTURB statename Diagnostic plots may be generated for all matrix coefficients or for all matrix coefficients whose correlation coefficients fall within a specified range of values Note Diagnostic plots ca
125. ind speeds to generate a power curve which takes into account all the dynamics of the system as well as the effects of turbulence To define the wind speeds to be used see Power curve calculation For better control of wind conditions it is recommended that instead of using Dynamic power curve calculation a series of separate power production simulations is run for a number of wind speeds The Annual energy yield calculation then constructs the dynamic power curve from these simulation results and simultaneously computes the annual energy yield The normal simulation outputs are not generated for each individual simulation Instead the output samples for certain variables which would normally be saved to output files are used instead to calculate the mean maximum minimum and standard deviation of that quantity at 75 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL each mean wind speed and it is these statistics which are saved as output As well as shaft and electrical power the statistics of gearbox torque thrust pitch angle and hub wind speed are also generated To define the sampling frequency and length of each individual simulation see Simulation control Caution this calculation uses a single turbulent wind history scaled for each wind speed Since the simulation time is constant the high wind speed simulations will use more of the turbulence history than the low wind speed simul
126. ind speed at that time e Wind direction measured clockwise from North see wind direction 6 7 3D turbulent wind Use this option to perform a simulation in which the turbine is immersed in a turbulent wind field which varies both in space and time This turbulent wind field is superimposed on any steady state spatial variations defined by wind shear tower shadow and an upwind turbine wake The turbulent variations at any point in the rotor disk have defined spectral characteristics and the variations at any two points in the rotor disk are correlated by a defined coherence relationship representative of the spatial structure of real atmospheric turbulence The turbulent wind field may have just the longitudinal component of turbulence or it may have all three components Click the Wind icon on the toolbar select Time varying wind and choose the 3D turbulent wind option Enter the following information e Turbulent wind file name Click here to select a file which contains an appropriate turbulent wind field see Generating turbulent wind fields The characteristics of the turbulent wind field will be displayed as you select a file The wind field should be high enough and wide enough to envelop the whole rotor and long enough to allow the simulation to continue for as long as is required If U is the average wind speed corrected to hub height according to the wind shear and the simulation is to run for a time T the wind fi
127. ining turbulence characteristics Click the Wind icon on the toolbar and select Define turbulence Then define following e Spectrum type select either von Karman or Kaimal to generate just the longitudinal component of turbulence or 3 component von Karman if all three components are required e Number of points along Y the number of grid points horizontally e Number of points along Z the number of grid points vertically e Length of Y the width of the turbulent wind field this should be at least the rotor diameter or the greatest distance from the tower centreline to the blade tip to allow for operation at non zero yaw angles e Length of Z the height of the turbulent wind field this should be at least the rotor diameter e Length of X the length of the turbulent wind field this should be sufficient for the length of simulation required at the appropriate wind speed The frozen wind field moves past the turbine at the specified wind speed corrected to hub height See 3D turbulent wind for details e Spacing along X the resolution to be used for the time histories This is expressed as the distance between successive points which move past the turbine at the appropriate wind speed e Mean wind speed this should correspond to the mean wind speed to be used for the simulations In fact the turbulence characteristics are used in dimensionless form which means that they only depend weakly on wind speed This means tha
128. inuity between a fixed and a pitchable or an aileron controlled part of the blade 10 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Use the Split and Join buttons to split or re join highlighted blade stations The first and last stations may not be split 3 1 Choosing blade stations Blade stations are the points along the blade at which blade geometry aerofoil mass and stiffness data are defined They are also the points at which blade loads will be calculated if desired see Defining outputs The blade stations must include the root and tip stations Blade station positions are measured from the blade root which is the point at which the blade is attached to the blade_root section Thus the first blade station must be given a radial position of zero and the radial position of the last station defines the length of the blade This will be less than the rotor radius if a blade root section is defined A reasonably even spacing between blade stations is recommended Try to define a blade station close to or preferably at the same position as any point mass which may be required see Blade mass distribution Discontinuities The blade may have sharp discontinuities in the mass distribution the stiffness distribution and the aerofoil section There will also be a discontinuity where a blade changes from fixed to pitchable or at the start or end of any aileron or airbrake section
129. l be the same as the actual yaw actuator torque since the dynamic response of the yaw torque actuator is assumed to be fast and is therefore not represented in the model 49 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 6 DEFINING THE ENVIRONMENT This section describes how to define the environmental conditions in which the turbine operates The environmental conditions include wind Section 6 1 waves Section 6 12 and currents Section 6 13 6 1 Defining the wind Click the Wind icon on the toolbar to define the characteristics of the wind field For the calculation of steady state parked loads and for all simulations define the steady state spatial distribution of the wind For simulations define also the time varying wind characteristics The steady state characteristics of the wind field may include any combination of the following elements e Wind shear the variation of wind speed with height e Tower shadow distortion of the wind flow by the tower e Upwind turbine wake full or partial immersion in the wake of an upstream turbine For simulations wind speed may vary with time in addition to the steady state spatial characteristics defined above Click on Time Varying Wind and choose one of the following options e No variation for simulations in which the wind speed and direction are constant in time e Single point history to supply a time history of wind
130. ler may choose to ignore this file if the information is not required The second file is used for the dynamic information exchange between the two programs It is called discon swp and is a binary file with a record length of 4 bytes The file must be opened 39 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL as a Shared file allowing simultaneous read and write access to both programs The file structure is given in Appendix A Although this file has many records it may only be necessary for the external controller to read from and write to a small number of these depending on the turbine type and the tasks which the external controller is performing Handshaking record 1 of discon swp is used for handshaking to ensure that neither program starts reading data until the other program has finished writing it The sequence of events to be followed by the controller program is as follows 1 Controller program starts by creating discon swp and writing a zero to record 1 2 Controller program waits until record 1 becomes 1 or 1 If it is 1 this indicates that the simulation has finished writing data and also that the file discon aux is ready if required If it is 1 the simulation is about to finish and the controller program should stop 3 If the first record is 1 the controller may read any of the parameters written by the simulation perform its calculations and then write the appropriate outputs Onc
131. longitudinal turbulence intensity is increased using the calculated added turbulence but the lateral and vertical turbulence intensities are not increased e Longitudinal others pro rata the lateral and vertical turbulence intensities are increased in the same proportion as the longitudinal turbulence intensity e Applied to all components default the variance of each component is increased by the same amount i e by the variance of the added turbulence For both wake models the wake centreline may also be offset from hub position of the target turbine by entering e Horizontal offset the horizontal distance between the rotor centre and the centre line of the wake A positive value indicates that the wake centre passes to the right of the rotor centre when looking in the direction of the wind flow e Vertical offset the vertical distance between the rotor centre and the centre line of the wake A positive value indicates that the wake centreline is above the target turbine hub 6 5 No time variation of wind speed Use this option to specify the wind conditions for a simulation when no variation of the wind field with time is required Any steady state spatial variations defined by wind shear tower shadow and an upwind turbine wake will apply Click the Wind icon on the toolbar select Time varying wind and choose the No variation option Enter the following parameters e Wind speed the steady wind speed to be used in the simula
132. n defined by default e Aerodynamics control e Calculation definition depending on which calculation is selected further parameters specific to the selected calculation These are all on the Calculation Parameters screen accessible from the Calculations screen or from the Specify pull down menu on the toolbar Having defined this fundamental data it should then be possible to perform the following steady state wind turbine calculations at a fixed rotational speed and pitch angle defined on the Calculation definition screen specific to each calculation e Aerodynamic information to examine the aerodynamics at each blade station such as lift and drag inflow tip loss etc at a specified wind speed e Performance coefficients dimensionless power torque and thrust coefficients as a function of tip speed ratio e Power curve at specified fixed rotor speed and pitch angle These calculations are quick and the results can instantly be examined graphically using the Data View icon on the toolbar From the power curve the annual energy yield can also be calculated This is one of the post processing calculations and again the results can be seen using Data View The Outputs button on the Calculations screen allows the user to specify in some detail which loads and other outputs are desired Once this is done the Steady state operational and parked loads calculations can also be carried out at specified fixed rotor speed and pitch angle
133. n itself and the wind field used if applicable They may be generated as stand alone reports or appended to another report such as a project report When reports are generated they may be appended to existing report files if desired Thus it is possible to create a project report and subsequently append calculation reports to it whenever calculations are done and also append calculation results either as graphs or tables 2 7 User preferences Select Tools and Preferences from the main toolbar menu and select desired options as follows Make backups of project files to make a backup file prx whenever a project file prj is opened Warn when starting calculation to display a warning when a shelled calculation is about to start Start batch jobs in foreground depending on the operating system jobs may run faster when running in the foreground Use binary format for calculation results binary output is faster and results in smaller files Report format Select ASCII or WORD 8 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Insert graphs as links to append graphs to WORD reports as links to external metafiles If this option is not selected graphs will be fully imported into the WORD document Network Dongle This option must be selected if you wish to use a network dongle otherwise it must be de selected If you have a network dongle you can change the way in which the network is searched by cl
134. n the Maximum generator speed The controller will adjust torque demand as above to maintain the desired tip speed ratio provided the generator speed lies between the Minimum generator speed and the Optimal mode maximum speed If cither of these speed limits is reached it is used as the speed set point for the Speed Control by Torque Demand PI controller The deviation of measured generator speed from this set point is the input to the controller and generator torque demand is the output Thus the generator torque is varied to keep the generator speed at the limit Note This PI controller remains active while the speed is between the limits but the torque demand output is constrained to lie on the quadratic curve defined by the Optimal mode gain Note also that energy output may not be maximised by maximising aerodynamic efficiency because the energy losses may also vary with the operating point It may therefore be better to track a slightly different tip speed ratio The desired tip speed ratio and the corresponding power coefficient should be used in calculating the Optimal mode gain as above Further details are given in the Theory Manual 5 7 4 Control in the variable slip case With a variable slip generator it is sufficient to set a high torque demand below rated the generator itself will restrict operation to the nominal slip curve This can easily be specified using the look up table option see Section 5 7 2 38 of 116
135. nd the rotor speed interval e Wind speed operating points define the minimum and maximum steady wind speeds required in the power production range and the wind speed interval e Azimuth operating points in most cases only one azimuth angle need be used e Idling Wind Speed the wind speed to be used for the idling range e The Maximum frequency to be plotted on the Campbell diagram e The Minimum correlation coefficient If the correlation between a particular state and state derivative is below this value a zero relationship is assumed between them The recommended value is 0 8 Model Linearisation The Model Linearisation calculation is only available for users with a licence for the Linearisation module It generates input and state perturbations and records the resulting variations in the state derivatives and the selected outputs This is done for a series of steady state power production operating points The Linear Model post processing calculation is then able to derive a linearised model of the turbine in state space form This is of particular value for designing controllers The parameters required are as follows e Wind speed operating points define the minimum and maximum steady wind speeds required and the wind speed interval e Azimuth operating points in most cases at least for 3 bladed rotors the rotor azimuth is unimportant and only one azimuth angle need be used e Wind speed perturbation e Pitch per
136. ndix B gives some simple examples of external controller code in several languages A 1 Data exchange records External controllers compiled as executable EXE files exchange information with the Bladed simulation through a shared binary file consisting of a number of 4 byte records External controllers compiled as DLLs exchange information through an array passed as the first argument to the DLL The structure of the binary file used for EXEs and the array used for DLLs is similar and is described in the tables which follow The type of each record of the file or element of the array may be integer real or character as specified in the tables In the EXE case the 4 byte records in the file should be written to and or read in as 4 byte integers 4 byte single precision real i e floating point numbers or groups of 4 characters as appropriate In the DLL case all the array elements are passed as real numbers so if an element is described as type Integer the real number must be converted to the nearest integer and integers being sent back to the simulation must be converted to real values Character variables are passed in separate arrays in the DLL case as described in Section 5 8 2 Table A 1 shows the array elements or binary file records which are used for data exchange between the Bladed simulation and the external controller As shown by the Data flow column some records are used to pass information from the simulation to the co
137. ned energy spectrum are required e Extreme deterministic waves regular waves are required Then enter the appropriate data in the active text boxes as described below Any specified waves will be ignored if the turbine is not offshore see Section 4 4 3 60 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 6 12 1 None no waves In this case the tower is not subjected to wave loading However if the turbine is specified as being offshore it will still experience hydrodynamic damping and a drag force from any specified currents 6 12 2 Jonswap Pierson Moskowitz spectrum The form of the Jonswap Pierson Moskowitz spectrum is described in the Theory Manual If this option is selected enter appropriate values for the following parameters in the text boxes below the wave selection panel e Peak spectral period the period of the most energetic component in the wave spectrum e Significant wave height corresponding to the average height of the highest one third of the waves in the seastate Given a time history of wave height this parameter can be calculated as four times the standard deviation of the water surface elevation e Peakedness parameter this parameter controls the width of the frequency band containing most of the energy in the spectrum It should take a value between 1 and 7 For a Pierson Moskowitz spectrum the peakedness parameter should be set to 1 e Random number seed an integer to be
138. ng facility for analysis of calculation results The following calculations are provided e Basic statistics to calculate the mean minimum maximum standard deviation skewness and kurtosis of a signal e Fourier harmonics to calculate the fourier components of a signal at multiples of rotor rotational frequency Periodic components to separate out the periodic and stochastic parts of a signal Extreme predictions to estimate lifetime extreme loads from a sample time history Auto spectrum to calculate the auto spectral density frequency spectrum of a signal Cross spectrum to calculate cross spectral density coherence and transfer functions between any two signals Probability density to calculate the probability distribution of a signal Peak analysis to calculate the probability density of signal peaks and troughs Level crossing analysis to calculate the probability of crossing any particular threshold Rainflow_cycle_count for cycle counting of a signal for fatigue analysis and calculation of damage equivalent loads Fatigue analysis to calculate fatigue damage e Annual energy yield to calculate the annual energy yield as a function of mean wind speed from a power curve e Channel combination to combine and scale a number of signals useful to produce a combined stress signal for fatigue analysis e Ultimate loads to find the maximum and minimum values of loads and concu
139. ns is available Optionally each segment may have a linear trend removed before windowing which can improve the spectral estimation at low frequencies The final spectrum is obtained by averaging together the resulting spectra from each segment The information required is therefore as follows e Number of points the number of datapoints per segment Must be a power of 2 maximum 4096 More points will give better frequency resolution which may be important especially at low frequencies However choosing fewer points may result in a smoother spectrum because there will be more segments If in doubt 512 is a good starting point 86 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Percentage overlap the overlap between the segments Must be less than 100 50 is often satisfactory although 0 may be more appropriate if a rectangular window is used e Window this may be a rectangular equivalent to not using a window b triangular 1 2f 1l c Hanning l cos 2nf 2 d Hamming 0 54 0 46 cos 2 nf e Welch 1 2f 1 Where f is the fractional position along the segment 0 at the start 1 at the end One of the last three windows which are all quite similar is recommended e Trend removal Usually desirable 8 6 Cross spectrum This calculates the cross spectral density coherence and transfer functions between any two signals Click the Select buttons to define the two s
140. nt aileron sections may be defined if required for use at different blade stations On the Blade properties window click on the foil section to be defined A drop down list allows an already defined section to be selected or select Define to open the Define Aerofoil Sections window This allows the characteristics of already defined sections to be viewed or edited or new ones created by clicking New To view or edit an existing aerofoil section In the Define Aerofoil Sections window select the section number required To set up a new aerofoil section In the Define Aerofoil Sections window press New to start a new foil section To edit an aerofoil section Click Add or Insert to increase the number of aerofoil datasets to interpolate between Click Delete to remove one Double click on any entry to open the Aerofoil Dataset Selection window This presents a list of all suitable datasets from the database they must be in ascending order of deployment angle If desired the selection criteria may be modified to further restrict the list displayed Select a dataset from the list and click OK No entries may be left blank To remove an aerofoil section There is no need to delete an aerofoil section if it is no longer needed at any blade station The sections which are still in use will be renumbered when the Blade Properties window is closed starting from 1 The aerofoil datasets themselves of course remain in the database
141. ntroller some are used to pass information from the controller back to the simulation and a few are used for two way communication Note that the first binary file record or array element is referred to as record or element number not 0 105 of 116 Garrad Hassan and Partners Ltd Record Data Data Document 282 BR 010 ISSUE 11 number flow type Description 1 30 32 33 34 35 36 37 38 40 41 42 43 44 45 46 47 48 continued overleaf in in in in in SESS SSS SSS SSS SSS See 5555 I MDH HADDAD DADA AAA A AAA MH AAAAAAAD Ala AAA AAAAAAAA See Section A 2 Current time Communication interval Blade 1 pitch angle Below rated pitch angle set point Minimum pitch angle Maximum pitch angle Minimum pitch rate most negative value allowed Maximum pitch rate 0 pitch position actuator 1 pitch rate actuator Current demanded pitch angle Current demanded pitch rate Demanded power Measured shaft power Measured electrical power output Optimal mode gain Minimum generator speed Optimal mode maximum speed Demanded generator speed above rated Measured generator speed Measured rotor speed Demanded generator torque Measured generator torque Measured yaw error Start of below rated torque speed look up table R No of points in torque speed look up table N Hub wind speed Pitch control 0 collective 1 individual Yaw control 0 yaw rate control 1 yaw torque
142. ocument 282 BR 010 ISSUE 11 FINAL The View Messages button displays any warning or error messages generated during the run In a few cases some additional information is available by clicking the Further Info button Other buttons allow whole runs or individual data groups to be deleted 2 6 Compiling reports If Microsoft Word is installed it is possible to generate neatly formatted project and calculation reports in Word format It is also possible to insert calculation results into these reports either as tables or as graphs See also User Preferences If Word is not available change the report format to ASCII using the Reports pull down menu This will cause reports to be generated in tab delimited ASCII format suitable for reading into other packages if required This option does not allow graphs to be inserted into the report Reports are generated from the Reports pull down menu on the main toolbar There are two types of reports e Project reports these may contain any currently assigned modules defining the wind turbine itself as well as calculation parameters and wind field details if required e Calculation reports these may be generated for any calculation which has been carried out or which is awaiting execution in the Batch queue A dialogue box allows the desired calculation to be selected Calculation reports may include any turbine details which are relevant to the calculation as well as details of the calculatio
143. odel linearisation calculation 72 7 11 1 Selection of model features for linearisation 73 7 12 Pitch and speed schedule 74 7 13 Simulation control 74 7 14 Dynamic power curve calculation 75 7 15 Aerodynamic models 76 7 16 Physical constants TI 7 17 Safety factors 77 7 18 Imbalances and Pitch Failures 77 7 19 Controlling the calculation outputs 78 7 19 1 Blade outputs 78 7 19 2 Tower outputs 79 7 19 3 Other outputs 79 7 19 4 Co ordinate systems 79 7 20 Specifying calculation options 83 8 POST PROCESSING 84 8 1 Basic statistics 84 8 2 Fourier harmonics 85 8 3 Periodic components 85 8 4 Extreme predictions 85 8 5 Auto spectrum 86 8 5 1 Options for spectral analysis 86 8 6 Cross spectrum 87 8 7 Probability density 87 8 8 Peak value analysis 88 8 9 Level crossing analysis 88 8 10 Rainflow cycle counting 89 8 11 Fatigue damage estimation 89 8 12 Setting bin limits 90 8 13 Annual energy yield 90 8 14 Channel Combination 91 8 15 Multiple Processing 92 8 16 Ultimate Loads 93 8 17 Ultimate Load Cases 94 8 18 Flicker 94 8 19 Linear Model 94 8 20 Data channel selection 96 8 20 1 Selecting independent variables 96 8 20 2 Messages and further information 96 8 20 3 Deleting information 97 iv Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 9 GRAPHICAL DATA VIEW FACILITY 9 1 Graphs of several variables 9 2 Graph styles 9 3 Grids and logarithmic axes 94 Units 9 5 Axis limits 9 6 Graph titles 9 7 Graph legends and line s
144. oise none rectangular distribution or Gaussian distribution For a rectangular distribution specify the half width of the distribution i e the maximum error For a Gaussian distribution specify the standard deviation The discretisation step for each signal may also be specified the signal is discretised after any random noise has been added 5 9 Transducers Transducer models are available to provide the following measured signals e Electrical power e Generator speed Each transducer is modelled as a first order lag Set a zero time constant to ignore transducer dynamics The electrical power signal is required for the in built dynamic fixed speed pitch regulated controller The generator speed signal is required for the in built dynamic variable speed controllers Both signals are available to the external controller if required The electrical power is at the turbine terminals i e net of any electrical losses including auxiliaries 5 10 The pitch actuator The dynamics of the pitch actuator are an important part of the control loop dynamics for pitch controlled turbines and must be defined before dynamic simulations can be carried out for these turbines Click Control on the main toolbar followed by Pitch Actuator or use the Specify gt Control systems pull down menu For aileron or air brake control the pitch actuator is actually an aileron or air brake actuator Simple passive actuator models are provided and are
145. omial Click Coefficients to define it Use Add to add terms to the polynomial and double click on an entry to edit or enter a value Enter a coefficient for each term of the polynomial f V is the sum of terms of V in the units defined above raised to the power of the order n and multiplied by the coefficient entered for that term Recommendations For pitch regulated turbines it is usually useful to apply gain scheduling to the above rated pitch controller This applies to both fixed speed and variable speed pitch regulated controllers This is because the sensitivity of aerodynamic torque to changes in pitch angle is much greater at large pitch angles and hence large wind speeds than close to rated The gain schedule may be defined as a function of pitch angle and it is often appropriate though conservative to set f pitch angle to be proportional to the partial derivative of aerodynamic torque with respect to pitch angle Once the steady state control parameters have been defined use the steady operating loads calculation to calculate the partial derivatives at each operating point using the Calculate pitch and speed change option 36 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Tip in practice for full span pitch regulated rotors pitching towards feather setting f pitch angle to be proportional to pitch angle is often a reasonable first approximation but this is unlikely to apply to part
146. on of Germanischer Lloyd 1 for the machine rotating with all blades iced Select Blades iced and enter the ice density p and the tip chord Cyin This should be linearly extrapolated from the blade contour according to 1 For the outer half of the radius the additional mass per unit length is given by 0 00675 0 3 exp 0 32R pC min Cmin max where R is the rotor radius in metres and Cmax 1s the maximum chord obtained from the blade geometry information Between the rotor centre and the half radius point the additional mass per unit length changes in proprtion to radius down to zero at the rotor centre The change in mass is reflected in the Turbine Info screen click the Mass Totals button to see this 3 4 Blade stiffness distribution For calculations involving blade flexing or vibrational dynamics it is necessary to define the stiffness distribution of the rotor blades Click the Stiffness checkbox off if calculations not involving blade flexing are desired and the stiffness data has not been defined The stiffness must be defined in both edgewise and flapwise directions at each blade station The stiffness is the product of the Young s Modulus for the material and the second moment of area for the edgewise or flapwise direction as appropriate The principal axes are assumed to be parallel and perpendicular to the chord line It is further assumed that they intersect on the pitch axis and that there
147. on shaft torque or power depending on the option selected or a two dimensional look up table on shaft speed and either torque or power If a look up table is used loss values will be linearly interpolated from the table The option to express losses in terms of power has been provided for convenience since data is sometimes provided in this form However this model is inappropriate at low rotational speeds If any calculations at low speed are to be carried out including start ups shut downs idling or parked simulations with slipping brake then it is advisable to recalculate the losses in terms of torque 4 9 2 Electrical losses Two alternative models are available for the electrical losses Linear model 28 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL This requires a no load loss L and an efficiency where the electrical power output Pe is related to the generator shaft input power P by Pe e P Lo Look up table The power loss L P is specified as a function of generator shaft input power P by means of a look up table The electrical power output P is given by P P L Ps Use the Add button to add points to the look up table Double click on a look up table entry to edit it 4 10 The Electrical Network From the Power Train button on the toolbar click Network to define the electrical characteristics of the windfarm network and the connection from the windfarm
148. r In the Ultimate Load Cases window click Add to select output files from ultimate loads calculations Select the required variables from the list of available variables To view the results click the Data view icon on the main toolbar and select the Special graph type Then find the calculation results by clicking Channel 1 The results will be presented as a histogram 8 18 Flicker Flicker is a measure of the severity of voltage fluctuations caused by equipment such as a wind turbine connected to the network It may be calculated either from a voltage time history or from active and reactive power Click the Select button s to define the time histories to use Range of data to use if desired flicker may be calculated from just a part of the time history To do this enter a To value which is greater than the From value If flicker is calculated from active and reactive power it can be calculated for a range of different network short circuit power levels and impedance angles in a single calculation Enter as many values as are required Set default values supplies a set of standard impedance angles See also Generator Network 8 19 Linear Model This calculation is available for users with a licence for the Linearisation module It converts the output of a Model Linearisation calculation into a state space model in a form which is suitable for controller design and is directly compatible
149. r a parked rotor in steady winds This optionally includes blade tower and other loads see Output Control Use the Steady parked loads screen see Calculation parameters to define the following parameters for the calculation e Steady wind speed note that although the wind speed is steady it need not be spatially uniform see Defining the wind e Azimuth angle the rotor azimuth position zero means that blade 1 is pointing vertically upwards e Yaw angle the nacelle angle measured clockwise from North assuming that the wind is blowing from the North see wind direction e Wind inclination for non horizontal wind flows e g on the side of a hill A positive value indicates a rising wind e Pitch angle the pitch angle or aileron flap airbrake deployment angle see Rotor The calculation also allows a sweep through any one of the four above angles i e azimuth yaw wind inclination or pitch angle Use Parameter to vary to define which angle will vary The sweep start at the value specified above for that parameter Specify End value to define the end of the sweep and Step to define the step size 7 11 Model linearisation calculation This calculation has two alternative forms e Campbell diagram e Model Linearisation Use the Model linearisation screen see Calculation parameters to select the calculation type and to define the parameters required for these calculations C
150. r detailed performance and loading calculations the dynamic model is more appropriate 4 6 2 Dynamic model This model includes the rotational degree of freedom of the rotor Torsional flexibility of the drive train may be included as an option The gearbox ratio must be specified along with the moment of inertia of the generator rotor including the high speed shaft and any brake disc etc Note that the moment of inertia of the turbine rotor is defined by the blade mass distribution and the hub inertia The rotor speed will be governed by the characteristics of the generator which must be defined in this case For a variable speed turbine it is also necessary to define an appropriate controller to define the speed schedule If there is a shaft brake to be used in stopping and parked calculations specify where it is located on the high speed or low speed shaft Click the Brakes button to specify the dynamic characteristics of the brakes Use the check boxes to specify if there is significant torsional flexibility in the low speed and or high speed shaft and supply the torsional stiffness Torsional damping may also be specified For fixed speed turbines the damping is unlikely to have much effect as it will be swamped by the damping provided by the induction generator In fact the damping may be sufficient to ensure that there is very little drive train torsional motion in which case it may be advantageous not to speci
151. r from the Calculations pull down menu on the toolbar or from the Calculations window by clicking the Run Now button For some of the steady state calculations and all the simulations the Calculations window also gives access to facilities for switching various calculation options on or off and for specifying the calculation outputs required Post processing calculations may also be initiated using the Execute button in the post processing window obtained by clicking the Analyse icon on the toolbar Long calculations may stacked up using the Run in Batch button in the Calculations window The whole batch of calculations may then be started so that they run one after the other for example overnight This is done using the Batch menu item on the toolbar Except for some auxiliary calculations the user will be asked to specify where the calculation outputs are to be sent A dialogue box allows the drive and directory to be selected and a run name must also be specified This is used to identify all the output files produced by that calculation A new output directory may be created by editing the directory name While the calculation is running a window appears which displays a progress bar showing how far the calculation has progressed together with any warnings which may arise during the calculation An Abort button allows the user to stop a calculation which is in progress Any part written output files which have already been produced sho
152. r in record number Mo where My M 1 and set record 49 to Mo note negative sign Choose Mo so that all these records occur after other output records for example My 61 In practice it does not actually matter if any of the records in Table A 1 are overwritten since they are refreshed each timestep The EXE controller must write to record 49 a zero should be written if there is no message 109 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL A 4 Pitch and torque override If the external controller is used for supervisory control actions such as starts stops while the built in continous time PI controllers are used for power production control then it may be necessary for the external controller to specify the instant at which the supervisory control action takes over from the in built controller action Set record or element 55 to integer 0 whenever the external controller is to control the pitch overriding the built in PI controller Set it to 1 when the built in PI controller should be controlling the pitch For variable speed turbines use record 56 in the same way to determine whether the external or the built in controller should be controlling the generator torque Note that in the EXE case messages should be written using Method 2 see Section A 3 if the override control is to be used The external controller will always take precedence if Method is used A 5 Sending logging output to Bladed
153. r operating point for example at one wind speed At a different operating point the gains may need to be modified because the relevant characteristics of the system may be different This is particularly true of pitch controlled turbines where the aerodynamic gain changes significantly with pitch angle and hence with wind speed The gain scheduling facility allows the overall gain of each PI controller to be modified as a function f V of some chosen variable V Thus the actual proportional and integral gains at any point are given by K f V and K f V where K and K are the proportional and integral gains as entered in the boxes provided The variable V is selected by clicking the arrow by Schedule on and choosing from the list The variables to choose from are Pitch in radians for pitch regulated controllers only Power in W Speed in rad s generator speed for variable speed controllers only Wind speed in m s note that in practice a suitable wind speed signal is unlikely to be available There are three possibilities for f V e Constant the gains are fixed with f V constant as defined by Value e Look up table f V is defined by a look up table Click LUT Data to open the table Use Add to add points to the table and double click on an entry to edit or enter a value The X values refer to the variable V in the units shown and the Y values are the corresponding f V e Polynomial f V is defined by a polyn
154. r to always return the results of the previous timestep s calculation Noise on measured signals if desired click Specify noise to specify any random noise and discretisation errors on the signals passed to the external controller External Controller Data optional The information you provide here will be placed in a text file DISCON IN which your controller is free to open and read when it starts up no path is required as the file will be in the Bladed directory which is the current directory when the external controller starts You can use this to pass additional parameters to your controller e g gains look up tables etc There is no need to pass the set points etc which are defined in the steady state part of the Control Systems window as these will be passed across in the communication file or array Note to enter a tab in this field press Control Tab 41 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Important note When using a user defined controller Bladed evidently cannot guarantee that the performance defined by the steady state control parameters will actually be achieved on average during a dynamic simulation 5 8 4 Signal noise and discretisation When using an external controller click Noise on measured signals and Specify noise to specify random noise and discretisation errors on the measured signals passed to the external controller For each signal select the type of random n
155. ressure in the hydraulic system Pump flow per unit yaw F the volume of fluid which must pass through the yaw motor to achieve a one radian change in nacelle angle Yaw torque per unit pressure Q the relationship between the pressure difference across the yaw motor and the torque developed at the yaw bearing Gas law constant the constant y for the gas in the accumulator In the gas law equation pv RT Specify y 1 for isothermal conditions The yaw torque Y provided by the hydraulic system is then given by 48 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL off where vi V F a v V F a and a is the difference between the actual and the demanded nacelle angle 5 17 2 Active Yaw Three choices are available for defining the demanded nacelle angle in simulations e None the demanded nacelle angle will be fixed at zero North e Prescribed manoeuvre specify a yaw manoeuvre by entering e Time to start yaw manoeuvre when the demanded nacelle angle starts to move e Required yaw position change the angle through which it will move e Yaw rate for yaw manoeuvres the yaw rate to be used e External controller if Rigid yaw or Flexible yaw is selected the user defined controller will generate a yaw rate demand which defines the demanded nacelle angle at any instant If Controlled torque is selected the user defined controller will generate a yaw actuator torque demand This wil
156. roup In some situations it is possible to select a number of data groups simultaneously 4 When the correct group has been selected select the desired variable in the box below Again in some situations it is possible to select a number of variables simultaneously 5 If appropriate select the independent variable as described below 8 20 1 Selecting independent variables Independent variables are shown in the box at the bottom of the channel selection screen The number of independent variables required depends on the context For example a line graph or histogram requires one independent variable shown as X Axis and a 3D graph requires two shown as X Axis and Z Axis For post processing the last independent variable usually time is selected by default and is not listed Where there are more independent variables than required particular values must be selected for the remaining variables by clicking on the variable and selecting a value in the box on the right Double click on a variable to change whether or not it will be used as an independent variable For example if the independent variables are Blade station radius and Time you may click on Blade station radius and select the radius required leaving Time as the X Axis for the graph Alternatively double click on Time to select a particular value of time and you can then plot the variable at that time as a function of blade station radius If you make both variables indep
157. rrent values of other loads e Ultimate load cases values of specified loads e Flicker to calculate the flicker severity due to voltage variations on the network caused by the wind turbine e Linear model to convert the output of the Model Linearisation calculation into a state space model suitable for control design for example using Matlab 2 7 to identify the load cases producing maximum and minimum Post processing calculations may be run from the Calculation screen by selecting the calculation required and pressing Run now or Run in Batch or from the Post processing screen obtained by clicking the Analyse icon on the toolbar by pressing the Execute now or Add to Batch buttons 8 1 Basic statistics This calculation generates the mean minimum maximum standard deviation skewness and kurtosis of a signal Click the Select button to define the signal to be processed If you have selected Multiple Channels you will be able to specify a number of load cases and variables to be processed in a single calculation and the results for each load case will then be stored as additional outputs of that load case 84 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Note that if the skewness and kurtosis are not required the remaining statistics may be obtained directly from the Data View facility 8
158. s and pitch failures to specify mass and aerodynamic imbalances and pitch system failures Parameters for specific calculations Aerodynamic information Performance coefficients Power curve Steady operational loads 7 10 Steady parked loads Model linearisation 69 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 7 6 Aerodynamic information calculation This is a simple steady state calculation which outputs the following aerodynamic information at each blade station Inflow factors axial and tangential Inflow angle Angle of attack Tip loss factor Reynolds number Lift drag and pitch moment coefficient Relative wind speed Aerodynamic loadings in plane force out of plane force and pitching moment per unit length of blade Use the Aerodynamic information screen see Calculation parameters to define the following parameters for the calculation e Wind speed e Pitch angle e Rotational speed of the rotor 7 7 Performance coefficients calculation This calculation generates dimensionless power torque and thrust coefficients for the rotor as a function of tip speed ratio assuming a uniform steady wind Use the Performance coefficients screen see Calculation parameters to define the following parameters for the calculation Minimum tip speed ratio Maximum tip speed ratio
159. s case the aerodynamic control surfaces must be defined appropriately on the Rotor and Blade screens The software rate pitch limits will be available to the external controller if required and the pitch actuator dynamics should be specified 5 2 The fixed speed pitch regulated controller Use this control model for a fixed speed turbine i e with a directly connected induction generator which has a pitch or aileron controlled rotor 5 2 1 Steady state parameters To specify the steady state operating curve supply the following data e Demanded electrical power the power set point i e the electrical power output required above rated wind speed e Minimum pitch angle the lower limit of pitch or aileron deployment angle e Maximum pitch angle the upper limit of pitch or aileron deployment angle e Select Pitch feathering or Assisted stall to specify the direction of pitching If Pitch Feathering is selected the Minimum pitch angle will be set for normal operation below rated wind speed and the pitch or aileron angle will increase above rated If Assisted Stall is selected the Maximum pitch setting is used below rated and the pitch or aileron angle decreases or moves to more negative values above rated 5 2 2 Dynamic parameters This controller varies the pitch or aileron angle above rated to regulate the electrical power output to the set point given above The following information is needed for simulations wh
160. s selected for active yaw with yaw rate control e demanded yaw actuator torque if yaw torque control was selected The controller may if desired change the status of the generator contactors and the brake A 2 Record 1 the Status flag In the EXE case record 1 of the shared binary file is used for handshaking as described in Section 5 8 1 In the DLL case element 1 of the DATA array is set by the simulation as follows 0 First call at time zero 1 All subsequent timesteps 1 Final call at the end of the simulation The DLL may set the value to 1 to request the simulation to terminate A 3 Sending messages to the simulation The controller may send a message to the simulation which will then be displayed to the user In the DLL case a separate argument to the DLL is provided for this purpose as described in Section 5 8 2 Element 49 of the DATA array gives the maximum number of characters allowed Each 1 byte element of the MESSAGE array can store one character of the message In the EXE case there are two methods of specifying the message which should not exceed 80 characters in length Method 1 obsolete Record 49 should contain the number of characters in the message and the subsequent records should contain the message four characters per record Method 2 recommended Place the message in records M onwards 4 characters per record Enter the number of characters in the message as an intege
161. ses can be switched off or on very easily using this feature for all calculations where energy losses are actually relevant 2 2 Entering data In each window data is entered by typing in the required information in the fields provided Where there is a choice of alternative options selection buttons or pull down selectors are provided In some cases check boxes are provided for enabling or disabling particular items the item is selected when a tick appears in the box Where numerical values are entered except in the case of dimensionless numbers the units in which the data is to be specified are shown Double clicking on the entry brings up a units conversion box allowing the user to enter values in a choice of different units Once data in a window has been edited it is necessary to assign the changes by clicking the OK button Alternatively any changes made since the data was last assigned may be reversed by clicking the Cancel button 2 3 Using project files A project file stores all the currently defined information relating to the wind turbine the wind field information and calculation parameters Click OK on any open windows to ensure that the data is assigned before saving to a project file A project report may be generated from the Reports pull down menu on the main toolbar 6 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 2 4 Performing calculations Calculations may be initiated eithe
162. slower simulations If the mountings are relatively stiff for example if they are intended for noise isolation then they will not influence loads significantly and are best omitted If they are intended to modify the rotational dynamics then they can be approximated by a corresponding reduction in shaft stiffness This will have little effect on rotor and tower loads but simulations will run faster 4 8 Generator The Power Train button on the toolbar also allows the generator to be specified The generator characteristics must be modelled if the dynamic drive train model is specified Three generator models are provided e Induction generator for constant speed and two speed turbines e Variable speed generator for variable speed turbines e Variable slip generator for variable slip turbines See also Defining the rotor Control 4 8 1 Induction generator This model represents an induction generator directly connected to the grid It is characterised by Rated slip the slip speed at rated power as a percentage of synchronous speed Rated power the power output corresponding to rated slip Synchronous speed the rotational speed of the generator rotor at zero load Generator time constant this is the short circuit transient time constant for the generator Note a small time constant may result in slower simulations If it is very small specifying a zero time constant
163. small time constant may result in slower simulations If it is very small specifying a zero time constant will speed up the simulations without much effect on accuracy The minimum and maximum generator torque limits must be specified Motoring may occur if a negative minimum torque is specified The phase angle defines the phase relationship between the current and voltage from the network side of the frequency converter and therefore the power factor It is assumed that the power factor is completely controllable by the frequency converter Drive train damping feedback the generator torque control may also include a built in feedback term derived from the generator speed by means of a transfer function This is superimposed on the torque demand from the controller and may be used to help damp out drive train torsional vibrations Specify the transfer function required in terms of numerator and denominator polynomials in the Laplace operator 27 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 4 8 3 Variable slip generator A variable slip generator is an induction generator with a controlled resistance in series with the generator rotor windings giving a fixed speed induction generator characteristic below rated and limited range variable speed operation above rated The parameters required are a combination of the fixed speed induction generator parameters and the variable speed generator parameters detailed above
164. speed and direction which is fully coherent over the whole rotor e 3D turbulent wind use a 3 dimensional turbulent wind field with defined spectral and spatial coherence characteristics See Generating turbulent wind fields e Transients to use sinusoidal wind speed and direction transients as defined by certain standards such as IEC 1400 1 These options are described below starting at Section 6 5 In each case the wind characteristics are defined at a specified height and the wind speed at other heights will be modified according to the shear profile Click Refer wind speed to hub height to ensure that the definitions always apply at the hub height of the turbine Click on View wind data for a graphical representation of the wind field The options available include e Time history plots for selected positions in the rotor plane e 3D carpet plots and animations showing the wind field over the whole rotor plane The variables which may be displayed include e Longitudinal lateral and vertical wind speeds e Resultant horizontal wind speed 50 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Total resultant wind speed e Wind direction and upflow angle This data may also be tabulated as for other graphical data The time history plots optionally include moving averaged values if a gust average period is specified Click Stats to see the mean wind speed and the maximum
165. t A dialogue box allows a document name to be chosen If it is an existing document you may choose to overwrite it or to append to it The Report Contents screen then appears Select the desired report contents by checking or unchecking the appropriate boxes By default this includes any currently assigned modules defining the wind turbine itself Calculation parameters and wind field details may also be added Click on OK to generate the report 103 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 10 2 Calculation reports Calculation reports can be written for any calculation which has been performed with a defined run name From the Reports menu on the main toolbar select Write calculation report A dialogue box allows a particular run to be chosen The Report Contents screen then appears Select the desired report contents by checking or unchecking the appropriate boxes Select the desired report contents by checking or unchecking the appropriate boxes If desired change the Destination selector to Other to change the report file name You may append to an existing report if desired Click on OK to generate the report If an Other destination was selected a dialogue box appears to allow you to select an appropriate file name 10 3 Adding calculation results to a report When viewing a graph click the Save button to save the graph to a metafile Then or at any later time go to the Reports menu on the ma
166. t only the location of the turbulent wind fluctuations e Centred on hub height The centre of the turbulent wind field is placed at hub height e Best fit for rotor and tower If the wind field vertical dimension is less than the height of the turbine the top of the wind field will be located at the height of the top of the rotor so that the wind field extends as far down the tower as possible If the wind field vertical dimension is greater than the turbine height the wind field will start at ground level and will envelop the whole turbine Turbulent variations below the bottom of the defined wind field will be taken from the lowest defined point The wind turbulence is defined at a number of grid points both the the rotor plane and in the alongwind direction In between these points either linear or cubic interpolation can be used to determine the turbulence Specify one of the following options for the interpolation scheme e Linear uses linear interpolation e Cubic in rotor plane only uses cubic interpolation laterally and vertically and linear interpolation in the alongwind direction e Fully cubic uses three dimensional cubic interpolation If desired specify also a superimposed sinusoidal wind direction transient This is particularly useful if only a single turbulence component is being used Enter the following parameters e Amplitude of direction change the peak to peak amplitude of the transient Note that the spec
167. t a new foil section To edit an aerofoil section Up to six aerofoil Dataset names may be entered in the boxes provided Click on any white or red box to open the Aerofoil Dataset Selection window This presents a list of all suitable datasets from the database they must be in ascending order of Reynolds number and thickness If desired the selection criteria may be modified to further restrict the list displayed Select a dataset from the list and click OK If fewer than six boxes are required the boxes used must form a rectangular pattern so that the interpolation scheme is fully defined The top left hand box must always be used To remove an aerofoil section There is no need to delete an aerofoil section if it is no longer needed at any blade station The sections which are still in use will be renumbered when the Blade Properties window is closed starting from 1 The aerofoil datasets themselves of course remain in the database 3 10 Defining aileron sections An aileron section should be defined for every blade station which is defined as Moving see Blade geometry if ailerons are specified for the aerodynamic control surfaces Flaps and airbrakes can be treated as if they are ailerons Aileron sections allow interpolation between a set of aerofoil datasets defined for different aileron deployment angles 18 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL A number of differe
168. t the mean wind speed used here to generate the turbulence need not be the same as the wind speed used in a subsequent simulation which uses the wind field since the turbulence will be re scaled accordingly However for strict conformance to the specified turbulence characteristics generate a different turbulent wind field using the correct mean wind speed for each wind speed to be used in the simulations e Turbulence seed this is a seed for the random number generator and should be an integer between 0 and 999 Change the seed to generate a different turbulent wind field with the same statistical characteristics 58 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Spectrum type select either von Karman or Kaimal and click Define to enter the detailed turbulence characteristics as follows Kaimal model enter the lateral vertical and longitudinal length scales to be used von Karman model the improved model is recommended This conforms with ESDU data items 85020 and 86010 Enter Number of components 1 2 or 3 components of turbulence can be generated Height above ground The hub height is recommended Surface roughness length For the terrain Latitude Turbulence characteristics are only weakly dependent on latitude except near the equator The appropriate length scales and turbulence intensities are calculated and displayed although it is possible to specify different turbulence intensities when se
169. ter the point masses in the table Click the Add button to add each point mass and then enter the data required by clicking on the appropriate entry Note that masses are automatically sorted by radial position To remove a mass highlight it by clicking on its number and click Delete For each mass the following data is required e Mass The Mass required 12 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL e Distance from root The radial position of the mass measured from the blade root e Chordwise position The chordwise position of the mass measured backwards from the leading edge as a percentage of the chord at that point 3 3 3 Vibration dampers Particularly when operating in stall the aerodynamic damping of the edgewise vibrational modes of the blades may be very low or even negative causing large vibrations and corresponding oscillatory loads To prevent this some blades are fitted with vibration dampers These consist of mass spring damper system tuned to vibrate at the resonant frequency Enter the mass frequency and damping factor fraction of critical damping as well as the damper position and the direction of vibration relative to the local chord line For the direction the sign convention is the same as for blade twist 3 3 4 Blade icing The blade mass distribution may be increased to represent the accretion of ice on the blades The ice mass is calculated according to the specificati
170. tes 1 4 Documentation Much of the information contained in this manual is also available in the on line help facility There is also a Bladed Theory Manual which explains in more detail the theory behind the calculation methods used Section 2 of this User Manual gives an overview of how Bladed can be used The later sections then provide more detail on each function Sections 3 to 5 explain in detail how to set up a model of a turbine Section 6 covers the specification of the wind field and the sea state for offshore turbines Section 7 then explains how to set up and run wind turbine calculations The post processing graphics and reporting facilities are described in Sections 8 9 and 10 respectively 1 5 Acknowledgements Bladed was developed with assistance from the Commission of the European Communities under the JOULE II programme project no JOU2 CT92 0198 2 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 2 USING Bladed This chapter gives an overview of the ways in which Bladed can be used It covers the following topics General description and layout of the user interface Entering data Using project files Performing calculations Viewing results Compiling reports More detailed descriptions follow in later chapters 2 1 General description and layout of the user interface On starting Bladed the main Toolbar appears together with the Calculations screen The Toolbar consists of a
171. the calculation methods used This user manual complements the theory manual by describing the operation of the user interface Much of this information is also available in the on line Help facility 1 1 Installation Bladed is designed to run on PC compatible computers under Windows 95 NT 2000 or later versions A Pentium computer with at least 8 MB RAM is recommended Bladed is supplied on CD and is installed by means of a setup program The setup procedure suggests an installation directory for the software but allows the user to change this if desired A directory on the local hard disk is recommended Except for demonstration and educational versions a software key or dongle is provided This should be inserted into the parallel printer port A network dongle can also be supplied on request The setup procedure can install the appropriate device driver and network licence manager The setup procedure also allows the installation of the Acrobat Reader if desired which is used to view the User and Theory Manuals on screen It also allows the installation of the Matlab runtime libraries which are used by the optional Linearisation module The preferred screen resolution is at least 1024 x 768 small fonts although a resolution of 800 x 600 is acceptable 1 2 Optional modules The Bladed package consists of a number of modules for which licences are separately available The following modules are available Module Cap
172. the right of each channel allows a choice of units for the variable being plotted where appropriate Two selection boxes are available for the case of cross spectra and transfer functions with composite units Selection boxes in the lower part of the Graph Parameters screen give a choice of units for the X axis where appropriate and for the Z axis in the case of three dimensional graphs 9 5 Axis limits The default axis limits shown in the lower part of the Graph Parameters screen may be changed if desired to alter the limits on the X and Y axes and also on the Z axis in the case of three dimensional graphs The default tick interval may also be changed Clicking on an entry with the Shift button depressed will freeze it so that it will no longer be updated automatically as channel selections and units are changed A second shift click will unfreeze the entry so that it will be automatically updated 9 6 Graph titles The default axis labels X Y and Z if appropriate and graph titles top and bottom may be edited in the lower part of the Graph Parameters screen Use a tilde to start a new line in the graph title Clicking on an entry with the Shift button depressed will freeze it so that it will no longer be updated automatically as channel selections and units are changed A second shift click will unfreeze the entry so that it will be automatically updated 9 7 Graph legends and line styles For two dimensional graphs a leg
173. tion e Height at which speed is defined the reference height to which the wind speed applies unless Refer wind speed to hub height has been selected If wind shear is defined the wind speed at any other height will be different e Wind direction measured clockwise from North see wind direction e Flow inclination for non horizontal wind flows e g on the side of a hill A positive value indicates a rising wind 6 6 Single point wind history Use this option to specify the wind conditions for a simulation when an arbitrary time varying wind speed and or direction is required but no spatial variation is required other than the steady state characteristics defined by wind shear tower shadow and an upwind turbine wake 53 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL Click the Wind icon on the toolbar select Time varying wind and choose the Single point history option Enter the following parameters e Height to which speeds relate the reference height to which the wind speed time history applies unless Refer wind speed to hub height has been selected If wind shear is defined the wind speed at any other height will be different e Flow inclination for non horizontal wind flows e g on the side of a hill A positive value indicates a rising wind Then use the Add button to add points to the time history For each point enter e Time this should start from zero e Speed the w
174. tion is a coloured light showing whether the calculation can be performed Red light No data available no calculation possible Yellow light Some data available no calculation possible Green light Sufficient data has been defined to perform the calculation The box below shows all the data items required for the calculation and indicates whether the relevant data has been defined or not Double clicking on any data item which is undefined opens the appropriate window so that the required data can be defined 7 2 3 Calculation options A number of machine and wind features once defined are available as options which can be switched on or off in some of the steady state calculations and simulations Click the Show options button in the bottom left corner The screen expands to show a list of the available options 7 20 with an indicator for each to show whether it can be used as follows No light grey This option is not available for the selected calculation Red light No data available option will not be used even if selected Yellow light Some data available option will not be used even if selected Green light Sufficient data is defined for the option to be used if selected Use the check boxes to switch on or off any desired option provided it is available for the selected calculation If a red or yellow dot is displayed the option will not be used even if selected as the necessary data has not been defined click on the option nam
175. tive fatigue load spectrum for the turbine 68 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL The following simulations may be run Power production i e normal running Normal stop Emergency stop Start up Idling Parked 7 14 The Dynamic power curve calculation is also available This is a sequence of Power Production simulations at different wind speeds The full dynamics of the turbine will be used for all these simulations together with the appropriate supervisory control parameters which define the stopping and starting logic and the state of the machine when idling or parked See also Yaw manoeuvre to cause the turbine to yaw during a simulation To define the length of the simulation and other parameters which control how the simulation proceeds see Simulation control 7 5 Calculation parameters Click the Calculation parameters button on the Calculations screen to define the parameters for controlling particular calculations These include general parameters as well as parameters for defining specific calculations General parameters e Physical constants to define air density and viscosity and gravitational acceleration Aerodynamics control to define the aerodynamic modelling parameters Simulation control to define how a simulation will proceed Safety factors to be applied to certain loads Imbalance
176. to the external network This is useful if the Electrical dynamics option has been selected for the fixed speed induction generator or if the phase angle is specified for the variable speed generator Then the network currents and voltages as well as active and reactive power will be calculated at the turbine the point of common coupling and the infinite busbar Click Network as shown and enter the resistance and inductance of the line connecting the turbine to the point of common coupling and of the line connecting the windfarm to the infinite busbar Enter also the voltage for which these impedance values were calculated If required specify the number of additional turbines connected at the point of common coupling These turbines will be assumed identical to the turbine being modelled and running at a constant current and voltage equal to that of the turbine being modelled at the start of the simulation The dynamics of the additional turbines is not modelled but the steady state voltage rise at the point of common coupling will be calculated 29 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 4 11 The nacelle Click the Nacelle icon on the toolbar to define the nacelle characteristics Check the Geometry checkbox to define the characteristics required to calculate windage loads Two models are available Drag model the following information is required e Nacelle length e Nacelle height e Nac
177. tower axes Rotational sense the turbine may rotate clockwise or anti clockwise when viewed from upwind Position the rotor may be upwind or downwind of the tower in normal operation e Speed type the turbine may be defined as a fixed or a variable speed turbine See also Generator Control e Control surfaces specifies whether the blade is fixed pitchable includes full or partial span pitch or aileron controlled includes any type of flap or airbrake See also Blade Geometry Control Start up Normal stop Emergency stop e Transmission select Gearbox or Direct Drive For a direct drive system either set the gearbox ratio to 1 or select the Direct Drive option here If the Direct Drive option is selected the generator mass is separately identified on the Hub screen otherwise it must be included in the Nacelle mass e Cut in wind speed the steady wind speed at which the turbine is brought on or off line in low winds e Cut out wind speed the steady wind speed at which the turbine is brought on or off line in high winds Clicking the Hub tab allows the hub configuration to be defined This is described in Section 4 2 20 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 4 2 Defining the hub From the Rotor screen click the Hub tab to define the hub characteristics Enter the Spinner diameter This is the diameter of any spinner or nose
178. troller if any user defined control logic is to be used 5 17 Yaw control 5 17 1 Yaw Dynamics Four yaw dynamics options are available Click the Yaw control button on the Control Systems window and select the appropriate option None the nacelle direction will remain fixed Rigid yaw the nacelle follows the demanded nacelle angle precisely Flexible yaw the nacelle yaws passively with respect to the demanded nacelle angle as a result of aerodynamic forces Controlled torque the yaw actuator torque is specified by the external controller 317 2 S172 If Flexible Yaw or Controlled torque is selected you may specify a Yaw friction torque and any Additional stiction The nacelle will only start to yaw if the balance of applied yawing torques at the yaw bearing bearing exceeds the friction plus the stiction torque and it will stop yawing if the balance of torques falls below the friction torque The applead torques include aerodynamic and inertial Mz torques and either the spring damper torque in the case of Flexible yaw or the Controlled torque If Flexible Yaw is selected specify the Yaw Damping if any and either the Yaw Stiffness if any for a linear spring model or select the hydraulic accumulator model The following parameters are required to model yaw compliance provided by a hydraulic accumulator system Gas volume V the volume of gas in the accumulators Nominal pressure P the equilibrium p
179. ts will be calculated about this axis e Pre Bend the distance that the blade bent away from the blade reference plane Positive pre bend is into the wind ie an upwind turbine usually has positive pre bend in order to increase tower clearance e Foil section an index number defining the aerofoil section at that station e Moving Fixed differentiates between a fixed part of the blade and a part which is movable to achieve aerodynamic regulation or braking either by bodily changing the pitch of that part of the blade or by deploying an aileron flap or other aerodynamic control surfaces 3 2 1 The blade reference plane This is an arbitrary plane containing the blade pitch axis relative to which the twist angle and pre bend are measured 3 3 Blade mass distribution For dynamic calculations it is necessary to define the mass of the rotor blades Click the Mass checkbox off if static calculations are desired and the mass data has not been defined 3 3 1 Distributed mass For each blade station enter e the Centre of mass position as a percentage of chord measured backwards from the leading edge and e the Mass per unit length at the blade station Click the Additional Mass tab to specify any point masses vibration dampers or ice build up on the blades 3 3 2 Point masses If additional point masses are required at specific locations along the blade click the Additional Mass tab and en
180. tting up a simulation run The old von Karman model allows either 1 or 3 components of turbulence to be generated All the turbulence length scales must be entered by the user This model conforms to ESDU 74031 To start from an existing turbulent wind field definition click Import details to select an existing turbulent wind file The parameters defining the turbulence in that file will then be loaded 6 10 2 Advanced options The Advanced options button allows the following additional functionality Gust iterator this option is available only with the Improved von Karman model of turbulence It will carry out an iteration in which the surface roughness is varied until a particular gust is achieved somewhere within the rotor swept area The turbulence intensity will change with surface roughness in accordance with the model The following parameters are required e Gust wind speed tolerance and averaging time the iteration will continue until the specified maximum gust defined as a block average with the specified averaging time is achieved within the specified tolerance somewhere within the rotor swept area e Hub height and rotor diameter these define where the rotor swept area is in relation to the lateral and vertical extent of the wind file Click Get current values to input the values currently available on the Rotor screen e Height of turbulent wind field together with the hub height this defines the verti
181. turbation e Generator torque perturbation Click Set default perturbations to obtain sensible default values It is unlikely that these will need to be changed unless the resulting model indicates problems of poor resolution perturbations may be too small or hitting non linearities perturbations may be too large If required it is possible to perturb the wind speed and pitch separately for each blade 7 11 1 Selection of model features for Model Linearisation and Campbell Diagram It is important to consider carefully the features of the turbine model which should be included in the model linearisation calculation A few examples are given below e Clearly if the model is to be used to design a control algorithm it must be an open loop model For example if designing a pitch controller the built in pitch PI controller should not be used or the gain should be set to zero Any external controller will not contribute any dynamics as it operates in discrete time so it will effectively be open loop e Azimuth dependent and certain other features may not be desired For example flow inclination wind shear tower shadow and upwind turbine wake yaw motion especially with friction gravity loads safety factors Imbalances and pitch failures Most of these may be switched off using the Calculation Options 73 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL
182. tyles 9 8 Cross plots 9 9 Tabular output of results 9 10 9 11 9 12 9 12 1 9 12 2 9 12 3 9 12 4 9 12 5 9 12 6 Refreshing graphs Graph configurations Multiple Plotting and Tabulation Graph configurations Replacing variables Replacing runs Sequence Control Tabulation of Ultimate Loads Output 10 REPORTING 10 1 10 2 10 3 10 4 10 5 APPENDIX A Communication Between Bladed And External Controllers Project reports Calculation reports Adding calculation results to a report Editing and printing reports Linked graphs A l Data exchange records A 2 Record 1 the Status flag A 3 Sending messages to the simulation A 4 Pitch and torque override A 5 Sending logging output to Bladed APPENDIX B Example External Controller Code In Selected Languages B 1 Simple example of DLL code written in C B 2 Simple example of DLL code written in FORTRAN 90 B 3 Simple example of EXE code written in FORTRAN 90 APPENDIX C_ The Bladed Demo APPENDIX D_ Bladed Educational REFERENCES FINAL 98 98 98 98 99 99 99 99 100 100 100 100 101 101 101 101 101 101 101 103 103 104 104 104 104 105 105 109 109 110 110 112 112 113 114 115 115 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 1 INTRODUCTION Bladed is an integrated software package for wind turbine performance and loading calculations The Bladed theory manual gives full background information and details of
183. uld be available This means that a long simulation can be stopped without losing the results which have so far been produced 2 5 Viewing results After a calculation has been completed the results can be viewed by clicking the Data View icon on the toolbar and selecting the desired data for each channel Up to six channels may be plotted on one graph The outputs from any calculation just completed will normally be selected by default Otherwise the dialogue box allows any drive and directory to be selected If the results of several calculations are available within the directory a pull down selector allows the user to choose the run name which was specified when the calculation was initiated The output files available from that calculation are shown in the Data Group window Selecting one of these displays a contents list for the file from which the user chooses the variable of interest Click OK to assign the data to the selected graph channel Often there is just one independent variable for example Time in the case of dynamic simulations Sometimes there is a choice of independent variables for example a blade bending moment from a simulation could be plotted either against time or radius Double click to change the choice of independent variable If two independent variables are defined a three dimensional graph will result Three dimensional plots are most useful for small datasets 7 of 116 Garrad Hassan and Partners Ltd D
184. use a much slower calculation and may generate very large numbers of plot files these are stored as enhanced metafiles in the selected run output directory with the following naming convention 95 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL lt RunName gt lt M gt lt W gt Az lt A gt lt row gt lt col gt lt gt lt cc gt emf lt RunName gt __ the run name selected for the Linear Model calculation lt M gt which state space matrix A B C or D the plot refers to lt W gt the operating point wind speed lt A gt the rotor azimuth angle lt row gt lt col gt which particular coefficient of the matrix the plot refers to lt gt OK for a coefficient which was accepted X for one which was rejected lt cc gt the correlation coefficient obtained for the best fit line 8 20 Data channel selection This section describes the procedure for selecting calculation results for viewing or post processing Click the channel selection button on either the graph parameters screen for viewing data or on any of the post processing screens Then take the following steps to find the data you require 1 Select the disk drive and the directory where the data is to be found using the selection boxes provided 2 Select the run name which identifies the calculation results 3 Click on the Data group containing the required data The Variables box below will show the data available in this g
185. used as the seed value for the random wave generation e Wave direction from North the bearing from which waves arrive at the tower Like wind direction wave direction is defined as the direction which the waves are coming from and not the direction that the waves are going to The angle increases positively to the East of North 6 12 3 User defined spectrum If the wave spectrum is known at the site of interest select this option and then click on the Define spectrum button A further window opens which allows up to 100 pairs of values of frequency and power spectral density to be entered Data entry boxes may be created and deleted by clicking on the Add and Delete buttons respectively Data points are automatically sorted by frequency Clicking on the Show button will reveal a plot of the spectrum as defined The values of power spectral density at the lowest and highest frequencies entered should be zero Values for the following parameters should also be entered in the text boxes below the wave selection panel e Random number seed an integer to be used as the seed value for the random wave generation e Wave direction from North the bearing from which waves arrive at the tower 6 12 4 Extreme deterministic waves This option allows a regular wave train to be defined Values for the following parameters should be entered in the text boxes below the wave selection panel e Extreme wave period the period of the regular wave
186. ut causing any instabilities A non zero integral gain is important to ensure that the steady state error is zero This means that the measured quantity settles at the desired value in steady state conditions The ratio K K is known as the integral time constant It is often useful or necessary to vary the overall gain of the controller depending on the operating point This is known as Gain scheduling see Section 5 6 Garrad Hassan will be pleased to undertake the design of any wind turbine controllers The desaturation time constant is used to prevent integrator wind up when the output y is constrained by limits If this is too long the controller may take too long to break away from a limit For example a pitch controlled machine crossing rated wind speed may take too long before the pitch starts acting On the other hand a very short time constant may result in slower simulations If the PI controller being modelled is actually implemented in discrete form as is usual then the desaturation time constant should be chosen to be somewhat 35 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL smaller than the discrete controller timestep Alternatively specify a zero time constant for instantaneous desaturation 5 6 Gain scheduling The gains of a closed loop controller such as a PI controller are designed to give good control i e stable operation with good tracking of the set point at one particula
187. will speed up the simulations without much effect on accuracy The following table shows the synchronous speed for some typical cases Grid frequency 50 Hz 60 Hz 2 pole generator 3000 rpm 3600 rpm 4 pole generator 1500 rpm 1800 rpm 6 pole generator 1000 rpm 1200 rpm 8 pole generator 750 rpm 900 rpm Alternatively click Electrical dynamics for a detailed representation which models the generator starting from its equivalent circuit parameters namely stator and rotor resistance and inductance mutual inductance number of poles grid frequency and voltage An auxiliary load may be specified in parallel with the generator to represent any power consuming auxiliary equipment which the turbine may have Power factor correction 26 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL capacitors may also be modelled This representation of the generator allows both active and reactive power to be calculated as well as voltages and currents For starting the generator click Soft start etc to specify a ramp time which a soft starter if there is one will use to ramp up the voltage from zero to the working value It is also possible to specify that the power factor correction capacitors are switched in in stages with a delay between each stage A choice of generator model orders is provided Choose a high order for higher accuracy or a low order for faster simulations Further details are provided in the Theory M
188. wing information is needed for simulations which include controller dynamics e Speed transducer time See transducers A power transducer may also be constant defined if desired The in built control algorithm uses the product of measured speed and generator torque to give a measured shaft power signal e Control algorithm Choose between PI and Discrete External and click Define to specify the details If you choose PI you must define both the torque and the power controller details See also Variable speed control below rated As for the fixed speed stall regulated controller it is possible to define an external pitch controller and a pitch actuator if required 33 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 4 The variable speed pitch regulated controller Use this control model for a variable speed turbine i e with a variable speed generator 4 8 which has a pitch or aileron controlled rotor 5 4 1 Steady state parameters To specify the steady state operating curve supply the following data Torque speed curve below rated See Variable speed control below rated Pitch feathering or Assisted stall Specify the direction of pitching Minimum pitch angle the lower limit of pitch or aileron deployment angle Maximum pitch angle the upper limit of pitch or aileron deployment angle If Pitch Feathering is selected the Minimum pit
189. y different tip speed ratio The desired tip speed ratio and the corresponding power coefficient should be used in calculating the Optimal mode gain as above 37 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 5 7 2 Look up table Click Data and enter a look up table of generator torque demand against generator speed using the Add button to add entries to the table The View button allows the curve to be visualised 5 7 3 Other parameters In addition to the above specify the Minimum generator speed and the Optimal mode maximum speed this must be no greater than the Maximum generator speed The controller will adjust torque demand as above using the optimal mode gain or the look up table provided the generator speed lies between the Minimum generator speed and the Optimal mode maximum speed If either of these speed limits is reached it is used as the speed set point for the Speed Control by Torque Demand PI controller The deviation of measured generator speed from this set point is the input to the controller and generator torque demand is the output Thus the generator torque is varied to keep the generator speed at the limit Note This PI controller remains active while the speed is between the limits but the torque demand output is constrained to lie on the specified torque speed curve In addition to the Optimal mode gain the Optimal mode maximum speed must be specified This must be no greater tha
190. y present and select Frequencies These may be edited by double clicking them if suitable field data is available However a more accurate approach is to modify the mass and stiffness distributions until the correct frequencies are calculated The modal damping may be modified too at this stage Select a mode and click View mode shape for a graphical display of the modal deflections If some of the modes have high frequencies it may be preferable to specify fewer modes since high frequency modes cause the simulations to run more slowly and tend to have less influence on loads than the modes of lower frequency 7 2 The calculations screen Use the Calculations screen to select the calculation required to define any parameters and options required for that calculation and to execute the calculation If not already present click the Calculations icon on the toolbar to open this screen 64 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL 7 2 1 Calculations available The calculations are arranged in four groups Supporting Calculations for modal analysis and generating turbulent wind fields Steady Calculations for rapid steady state wind turbine calculations Simulations for detailed wind turbine simulations Post Processing for further analysis of results First click on the desired calculation to select it 7 2 2 Data required for calculations Alongside each calcula
191. y zero to start at the beginning of the turbulence history e Blade station economiser this can be used to speed up simulations by setting a value greater than zero Then the full aerodynamic calculations will only be carried out at a few 74 of 116 Garrad Hassan and Partners Ltd Document 282 BR 010 ISSUE 11 FINAL blade stations on trial integrator steps while other stations will be interpolated All stations are fully calculated at each complete integrator step so there is very little loss of accuracy Enter a percentage of the rotor radius representing the approximate interval between stations at which full calculations will always be carried out A value of about 35 is recommended Set zero to ensure maximum accuracy e Refine initial states This option carries out an initial iteration to find the steady state values of the states This may help to prevent transients at the start of a simulation and is also particularly recommended for the Model linearisation calculation The iteration does not include the yaw state at present The following parameters may be used if necessary to fine tune the performance of the variable step integrator e Integrator tolerance this parameter defines the accuracy of the simulation A value of 0 005 is recommended to start with but in special cases this may need to be reduced to improve the accuracy at the expense of slower simulations The usual symptoms of insufficient accuracy are unexplain