1. www trycom com tw Main menu Welcome to Serial Server s web Settings ModelName SerilSever4S _ Network Settings MAC Address 00 50 C2 1B 7F 01 Operating Settings Firmware version 1 24 15NOV1O CiAccessible IP Serial Server is 45 Device Auto Warning This web console provides the following function groups settings L3Change Password Basic Settings Load Factory Server name real time clock time server IP address and web console Default disable function Network Settings E3Savelrestart IP address netmask default gateway static IP or dynamic IP DNS 57 Logout serial Settings Baud rate parity data bits stop bits flow control interface Operating Settings Operation mode TCP alive check inactivity Accessible IP settings Accessible IP or Accessible IP group Disable to accept all IP s conne Auto Warning Settings c Telnet Telnet 192 166 3 22 Model Name erialServer45 MAC Address 00 50 C2 1B TF 01 Serial Number 16 Firmware Uersion 1 24_15NOU10 lt lt Main Menu gt gt 1 Basic Settings 2 Network Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Monitor Ping Password Settings Load Factory Defaults View Settings Saue Restart Quit your selection 4 1 Installing Serial S
2. Apply Change Discard Change Port Mapping ex ExportPort Mapping E Import Port Mapping Auto IP Address Report Ready 1 1 2002 00 25 15 2 step7 TRP C34H Real COM Mode setting OK Notice No matter how to change Add device or Remove Device its need to be run Apply change for save COM Port configuration i Serial Server Admin Utility File Function PortMapping View Help Jnlx COM Number 1 SerialServer45 192 168 3 22 1234 CONS server Manager p ES 9 2 SerlalServer4S 192 188 3 22 1235 CONG 3 SenalServer4s 192 168 3 22 1236 COM 1237 CONS 102 1 23 server Monitor 1 COM Port Configuration 5 applied Ok 9 Y 4 Port Monitor 8 mS ow OK a Port Mapping Auto IP Address Report Steps plug in RS232 LOOP back connector 28 RXA TXA TXB RAC TAG RXD TxD COMA COMB COMC COMD UUCo7U ou Oo Look Back Test 9 Female Short PIN1 4 6 PIN 2 3 PIN 7 8 15 x COMI COM GOMA Input 00000000 Input 00000000 Input 00000000 E but 00000000 Options DEMO Show ies Start Look start Part COME Input 000000 End Port 7 Canto 00000000 Output 000000 jut 00000000 Baud Rate ria BENED Data Bits Parity stop Bits
3. i 0 99 Timeout 0 65535 ms Step5 TRP C34H Server setting Select Operating Mode and then double click Port1 Port4 item same below 36 Server Manager Accessible IPs Auto Warning IP Address Report Passwol Information Basic Settings IP Settings Port Settings Operating Mod Model Name SerialServer4S OP Mode TCP Server Mode TCP Server Mode TCP Server Mode MAC Address TCP Server Mode 00 50 C2 1B 7F 22 Serial Number Firmware Version 1 24 15 10 View settings Settings Click the Modify check box to modify the configuration OK CANCEL a Port 1 Setting Operating Mode Operating Made server Made Dea Server Mode Settings Local TCF Fort 4001 Connection Misc Optional TCP Alive Check Timeout 0 99 min Timeout 0 85535 ms J Cancel b Port 2 Setting 37 Operating Mode Operating Mode server Mode Serer TCP Serwer Mode Settings Local TCP Part 4002 Max Connection Misc Optional TCP Alive Check Timeout 0 99 min Inactivity Timeout 0 65535 ms Port 3 Settings Operating Mode TCP Server PS LA TNI Laban Gort Dor eI rater s PR E Operating Mode TCP Serwer Made TCP server Mode Settings Loca
4. mud e TRP C34H R5232 422 485 PLC Ethernet COMC IPM 9 55 R 232 422 485 PLC COMD 85232 422 485 PLC Bua Enp ELIT IIT 5 88 Hest R5232 or R5422 485 device 41 TRP C34H up to 16 Real COM or 16 TCP Port only one IP TRP C34H Etherried TRP COBX 1 08 TRP C34H with TRP CO8X TRP CO8S TRP CO8H TRP CO8U TRP C29U Ethernet USB to 4 R5232 422 485 Converter TRP C34H 85 USB to 1 R5232 and 1 R5422 485 Isolated Converter TRP COBH USB to 2 R5232 and 2 R5422 485 Isolated Converter 1 58 TRP COBU USB to 4 R5237 Isolated Converter TRP C29U USB to 8 Channel Isolated DI and Isolated DO TRP COSX 085 TRP CO8H TRP COSU TRP C291 e 7 9 TRP COSX 085 TRP CO8H e 9 TRP COSX TRP CO8S TRP CO8H TRP CO8U 291 eo 9 9 TRP C23U 42
5. COMB ae e COM A Please use screwdriver and then open back of metal adjust the switch to select RS232 or RS422 485 2 5 Push Button If lost the password or IP user can keep push button for restore factory default till the PWR LED off and then reboot 2 6 Four RS232 D SUB male PIN assignments DCD 1 RXD 2 TXD 3 DTR 4 GND 5 DB 9 Male RE CTS 8 RTS 7 DSR 6 2 7 Four RS422 485 Screw Terminal assignments SO COMA COMB COMC COMD 3 Installing TRP C34H Hardware STEP1 Please use screwdriver and then open back of metal adjust the switch to select RS232 or RS422 485 function STEP2 Connect the power source from DC Jack or screw terminal the PWR LED will blinking wait till boots PWR LED ON STEP3 Connect TRP C34H with Ethernet port by RJ45 cable If the cable is properly connected the LINK LED will light up TRP C34H Support Auto MDIX A straight through or crossover RJ45 cable can be used to make a connection directly to the HUB Router PC LAN port STEP4 Connect TRP C34H to RS232 device by Null Modem cable Connect TRP C34H to RS422 485 by AWG 12 30 twisted pair wires 3 1 RS485 Wiring The RS 485 mode supports the Transmit and Receive channels use twisted pair wire half duplex operation 1 425485 Slave Device RS4B5 Slave Device TX D 1 TX D 21
6. Action then clicks Connect 39 Action Settings Input 00000000 Input 00000000 Input 00000000 Input 00000000 Output 00000000 Output 00000000 Output 00000000 Output 00000000 Input 00021960 Input 00021960 Input 00022000 Input 00021960 Output 00022040 Output 00022040 Output 00022040 Output 00022040 DEMO B E E E O x 40 6 TRP C34H Application Diagram Host PC Ethernet COMA COMB COMC a COMD TCP Real Mode Ethernet Paired Mode Client TRP C34H T Ethernet COMC E COMB i 0 COMA _ gt RP C34H COMB Server COMD 1 TCP Client to 4 TCP Server Broadcase TRP 6344 COMB Ethemat G Ethernet COMC 8 TRP C34H come COME Y TRP C34H a COMIC TE d aM 4 COND Server COMA TRP C34H EOM COMD 4 TRP C34H e gt COND Server gt 1 Serial Device to 4 TCP Host at Same Time Broadcase Bast Hiii Hear Hol 5 QU R5232 422 485 PLC COMB H
7. C34H on the network To view the web console open any web browser eg Internet Explorer and type the IP address in the address bar of the browser A login form prompting for password appears Login to the web console by entering the correct password and click submit Default Password is 24 E Serial Server Web Console Microsoft Internet Explorer Fle Edit View Favorites Tools Help Back 5 ER u 5 ec www trycom com tw ee Welcome to Serial Server s web Overview Basic Settings Model Name SerialServer4S Network Settings MAC Address 00 50 C2 1B 7F 01 Serial Settings Serial No 0 qm 6 i Operating Settings Firmware version 124 15NOVIO L3Accessible Settings Serial Server is a 4SP Device E3Auto Warning This web console provides the following function groups settings A BHRDNETRSSWOFd Basic Settings Load Factory Server name real time clock time server IP address and web console Default disable functian E3Upgrade Network Settings L3Savelrestart IP address netmask default gateway static IP or dynamic IP DNS 57 Logout Serial Settings Baud rate parity data bits stop bits flow control interface Operating Settings Operation mode TCP alive check inactivity Accessible IP settings Accessible IP or Accessible IP group Disable to accept all IP s conne Auto Warning Settings 4
8. all the serial ports present on the Serial Server model of the selected device It also shows the corresponding serial settings in the settings column of the page In order to see the current settings of any Serial port select the port number in above window amp then click on View settings To modify the serial settings check the modify box on the serial page Then View settings tab would be converted into Settings tab as below Accessible IFs Auto Warning Address Report Fasswnl Basic Settings Settings Fort settings Operating Modify Port Ali Settings O 1 1152 bps 8 hit Mane 1 hit Hone R S 232 2 115200bps 8 bit None 1 bit None RS 232 3 1152 0 bps 8 hit Mane 1 hit Hone R S 232z 4 115200bps 8 bit None 1 bit None RS 232 iew Settings select any Serial Port and click on the Settings tab which will show serial settings dialog where all parameters can be viewed in enabled state 16 Click the checkbox Apply Port Alias to all selected ports to apply same port alias to all selected ports Maximum length of Port alias is 5 characters Click the specific drop down box or click the check box to modify the serial port settings viz Baud Rate Parity Data Bits Stop Bits Flow control Interface If Serial applications like Hyper Terminal opens a COM Port with any of above port Numbers in a Virtual PC then the serial settings of that particular port c
9. i Give the Mail Server IP address amp authentication if required li Give from ID amp To ID Select on what event you want to be notified by mail in Eventtype page To get Auto Warning Trap Messages 22 i Key in the IP address of the Linux Machine Trap server option li In Network settings page enable SNMP and provide community name contact and location information 11 Run this command on Linux PC snmptrapd f Le iv Select the event type which you want to be notified v On that event notice that some messages will get printed on the console where you are executing the above snmptrapd command IP Address Report Page Network management becomes difficult when TRP C34H is forced into DHCP Any IP changes due to DHCP in TRP C34H are reported to the assigned Host on the Network On IP address Report click the modify box to activate the parameter and set the IP address Port number and time period to Auto report to host 23 The default Port number is 4002 and the default Auto Report Period is 10 s Password Password can be set modified amp Disabled through this screen Maximum length of 7 characters can be supported for TRP C34H password Alpha Numeric amp Alpha numeric type of passwords are supported Space is not allowed between any characters in password 4 2 using the WEB Server mode TRP C34H support web console for remote configuration of the TRP
10. when serial data arrives After the data has been transferred TRP C34H can automatically disconnect from the host computer by using the TCP alive check time or Inactivity time settings This Operating Mode supports establishing the TCP connection up to 4 Destination Hosts UDP Mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can multicast data from the serial device to multiple host computers and the serial device can also receive data from multiple host computers making this mode ideal for message display applications TRP C34H hardware support wide range power input the 4 RS422 485 interface with surge over current over voltage protection the RS485 interface built in hardware decoder ensure RS485 data without lost Soecify hardware can ensure on line RS485 device working fine The TRP C34H has four synchronous D SUB 9 pin serial port for RS232 connection and 4 screw terminal block for RS422 485 and power connection The Ethernet port support Auto MDIX and Auto select 10 100MB When TRP C34H working at unstable voltage industrial environment the hardware circuit detection can prevent the power fail cause of the boot fail and Re Boot 1 1 Features e Wide input range DC power supply Supports Socket operation modes like TCP Server TCP Client and UDP using TCP IP and UDP protocols Support Auto MDIX twisted pair crossover detection and auto correction Low cost solution and easy to suppo
11. 3 TRP C34H implements Telnet Server and be invoked by making Telnet from remote PC In the Basic Settings page of Windows Configuration Utility if the Enable Telnet Console check box is enabled we can use the Telnet Console to modify the device parameters Go to Start Menu gt Run Run Telnet from remote pc with the IP address of TRP C34H as shown below Type the name of program Folder document or Internet resource and Windows will open iE Far you 29 5 Application 5 1 Real COM Mode TRP C34H Basic 4 Real COM Port installs i Ethernet _ t Example Step1 Connect PC RJ45 TRP C34H RS232 422 485 Device Step2 Run Serial Server Admin Utility and Right Click on the selected device and click on configure to go to Configuration menu otep3 Be sure IP Setting Port Setting and Operating is correct EU Accessible IPs Auto Warning IP Address Report Passwol Basic Settings 1 Je Settings 2 Por Settings 3 Operating Modi erver Manager Information Model Name SerialServer4s OP Made Heal COM Mode Real COM Mode Real COM Mode Real COM Mode MAC Address 00 50 2 1B 7F 01 Serial Number 16 Firmware Version 1 24 15 0 10 View settings Click the Modify check box to modify the configuratio
12. 4 COM 2 COM 3 Host PC a COM 4 08 08 08 1 4 TRP C34H Support TRP C08X C08S C08H C08U C29U Diagram TRP C08X TRP C08H TRP CO8U TR C29U connected to any of the P1 P2 P3 USB Ports of TRP C34H to support 6 8 10 12 14 16 Serial Port interfaces or Maximum 24 Channel I O with TRP C29U TRP C34H with TRP CO8X TRP CO8S TRP CO8H TRP CO8U TRP C29U USB to 4 R5232 422 485 Converter 085 USB to 1 R5232 and 1 R5422 485 Isolated Converter USB to 2 R5232 and 2 R5422 485 Isolated Converter TRP COBU USB to 4 85232 Isolated Converter TRP C28U USB to 8 Channel Isolated DI and Isolated DO TRP C34H Ethernet TRP COBS TRP COBH TRP COBU 290 08 P or or TRP CD85 TRP CO amp SH 085 8 TRP CO8U TRP C29U 2 Hardware Description 2 1 Panel layout and Dimension 290 2282 29 15 23 25 EE COMB OMG COMB 5 Som 6 3220 80 00 3 15201 144 60 5 6972 mm Unit Notice User can only choose either external DC Jack or Screw terminal DC input Do not use DC Jack and screw terminal DC input simultaneously 2 2 LED indicators PWR LED Blinking Not Ready ON Stand By LINK LED Ethernet cable c
13. Flow DTR DSR lv RTS CTS otep9 Select Action then clicks Connect 29 lll DEMO Ce lolx Action Settings Input 00000000 Input 00000000 Input 00000000 Input 00000000 Output 00000000 Output 00000000 Output 00000000 Output 00000000 Input 00021960 Input 00021960 Input 00022000 Input 00021960 Output 00022040 Output 00022040 Output 00022040 Output 00022040 5 1 1 Appendix Easy to support multi ports TRP C34H supports 1 2 3 TRP C08X up to 8 12 16 COM Port TRP C34H lt COM 1 2 Ethernet 4 4 08 lt COM 5 4 4 i COME TRP CO08X i COM 9 i COM 10 COM 11 A COM 12 08 lt COM 13 i COM 14 4 COM 15 lt COM 16 Step1 Power off the TRP C34H and then connect TRP C08X Step2 Power on the TRP C34H will auto detection and configuration otep3 All operator steps same 5 1 30 ij Serial Server Admin Utility File Function PortMapping View Port Mapping 16 Port s IP Address TCP Port COM Number 1 SerialServer16S 182 158 3 2 1234 COME Server Manager 2 2 2 Ser
14. IP Settings 2 Pon Settings de Operating Modi Information Model Name SerialServeri2s Real Mode Real COM Mode Real COM Mode MAC Address 2 TCP Server Mode 00 50 2 18 7 01 TCP Server Mode TCP Server Mode TCP Server Mode TCP Server Mode TCP Server Mode TCP Server Mode TCP Server Mode 4 Co Ul Co Serial Number 16 Firmware Yersion 1 24 15 10 View settings Settings Click the Modify check box to modify the configuration OK CANCEL otep4 Select Server Monitor then right clicks Add Device Step5 Select Go ij Serial Server Admin Utility File Function Server Monitor view server Monitor Stopped IP Address Model MAC Address 192 1 ETE GO CO 1Bt 7 3 i at server Manager Remove Device Load configured Ports Server Monitor p UT ews Port Monitor Settings Stop Port Mapping Auto IP Address Report Step5 Connect PC COM Port link TRP C34H COMA COMD by NULL Modem Cable otep6 RUN and select correct baud rate and data format otep RUN Telnet exe and input IP and Port x IS9ABCDEFGHIJKLMNOPQRSTUUWXYabcdedky ut 00000000 put 00000000 S8SABCDEF GHIJKLMNOPOQRSTUUWAYabcded 8 39ABCDEFGHI JKLMNOPQRS TUUWAYabcded SSABCDEF GHI JKLHNOPQRSTUUI XV abcdeOomM ut 00000000 itput 00000000 8 JKLMNOPQRS TU
15. RP C34H b Click the Max Connection drop down box to set Max connection options to 1 2 3 4 c TCP Alive Check Timeout Default setting is 7 min d Inactivity Timeout Default setting is 0 22 Disabled 18 Hodes Senn Mote TOP Smia Sahii Local Fari Rise D prone TOF Abys Cheech Taped Tiri TCP Client Mode a Click the Connect Mode drop down box to set Startup Any character b Setting Destination IP address 1 and Port Number allows TRP C34H to connect actively to the remote host whose address is set by this parameter c Similarly Destination IP addresses 2 3 4 allows TRP C34H to connect actively to the remote hosts whose address is set by this parameter d TCP Alive Check Timeout Default setting is 7 min e Inactivity Timeout Default setting is 0 gt Disabled eke Hade herd Mode praet Lin Deira Host 55 D pim Alro chuck UDP Mode a Local Listen port The UDP port that uses to listen to Data from multiple host computers and also to multicast data to multiple host computers b UDP Mode Setting Destination Destination IP address 1 2 3 4 19 Accessible IP s Page Accessible IP settings allow you to add or remove legal remote host IP address to prevent unau
16. SOOO SOOM X OX RX RX 3 2 RS422 Wiring The RS 422 mode supports 4 channels with full duplex operation use dual twisted pair wire half duplex operation TX D Es TX D RX RX e RX Tx RS422 Slave Device 3 3 RS232 Wiring Refer to the Pin out table for connections 10 DCD 1 0 DCD RXD 2 os TXD TXD 3 RXD DTR 4 1 DSR GND 5 sno DSR 6 44 a DTR RTS 7 CTS CTS 8 O uat RTS RUG RI a 4 How to configure TRP C34H There are 3 ways to access the TRP C34H a Serial Server Admin Utility Fl Serial Server Admin Utility Function Server Manager View pu server Manager Found 1 Device s Ag Model Address IP Address Status 1 SenalServer4S 50 Cz2 1B 7 192 168 3 22 Locked server Manager Server Monitor gt Monitor Port Mapping ae ial Auto IP Address Report lReady 172602 00 15 44 b WEB Server 11 E Serial Server Web Console Microsoft Internet Explorer File Edit View Favorites Tools Help x 2 P 34 Search xr Favorites Address 92 158 3 22 cgi bin script cgi session l1 amp flena me database 18formno 1 5 222 Try Hx
17. TRP C34H Ethernet to 4 RS232 422 485 Converter User s Manual Printed Mar 2011 Rev 1 0 Trycom Technology Co Ltd 1F No 2 11 Sihu street Yingge Township Taipei Taiwan ROC Tel 886 2 86781191 Fax 886 2 86781172 Web www trycom com tw Copyright Copyright Notice The information in this manual is subject to change without prior notice in order to improve reliability design and function and dosed not represent a commitment on the part of the manufacturer No part of this manual may be reproduced copied or transmitted in any form without the prior written permission of manufacturer Acknowledgment Products mentioned in this manual are mentioned for identification purpose only Products manes appearing in this manual may or may not be registered trademarks or copyright of their respective companies 1 Introduction TRP C34H 4 5232 422 485 Serial Server provides a transparent way of connecting Serial devices over Ethernet It can transmit data between the Serial and Ethernet interfaces bi directionally To establish automatic or remote data acquisition TRP C34H solution can easy to connect to TRP C08X which support 16 Real COM TCP Port by USB cable with only one IP address By specifying the IP address and the TCP Port number a host computer can access different Serial Devices such as Serial Modems Serial Thermometers Magnetic Card Readers Barcode Scanners Data Acquisition Systems POS Terminals Industrial PCs etc ove
18. UWAYabcded laa SS9ABCDEFGHIJKLMNOPOQRSTUUWXYabede ea 5 R3232 427 485 PLC COMB t AS232 422 435 PLC R5232 422 485 PLC Server ES BRL Hiii PC pare g oe R3232 422 485 PLC ten 5 3 Paired Mode Paired Mode lt gt TRP C34H COMB COMB th m 2 COMC Client Server COMD COMD PC Example 33 Paired Mode Port 4001 Destination IP 192 168 3 24 4001 34 8 COMB Ethernet p Destination IP 192 168 3 24 4002 4 3 ue SS TE COMC Yd Destination IP 192 168 3 24 4003 4003 CO Client Server COMD 1 i Ort Destination IP 192 168 3 24 4004 4 3 182 168 3 22 192 468 3 34 gt Operating TCP Client Mode Operating TCP Server Mode Step1 Run Serial Server Admin Utility and Right Click on the selected device and click on configure to go to Configuration menu otep3 Be sure IP Setting Port Setting and Operating Mode is correct otep4 TRP C34H Client setting Select Operating Mode and then double click Port1 Port4 item same below Server Manager A Accessible IPs Auto Warning Address Report Information zip IP Settings Port Set
19. ddress Report Fasswnl Basic settings Settings Fort settings Operating Modify Met Mask Gateway IP Configuration DAS Serverl DAS Server Modify V Enable SNMP Community Name public Location Contact Modify subnet i i i Gateway On IP Settings Page click the modify box first you can modify all the Network parameter IP address Net Mask Gateway Click the IP Configuration drop down box to modify the parameter Static DHCP BOOTP Brari arg Vien Pup Itm fiers Pa s e DNS Server 1 When the user wants to visit a particular website the computer asks the Domain Name System DNS Server for the website s correct IP address and the computer uses the response given by DNS Server to connect to the Web Server DNS is the way that Internet Domain Names are identified and translated into IP address 15 f DNS server 2 An optional alternative of DNS Server g Community Name A community name is a plain text password mechanism that is used to weekly authenticate queries to agents of managed network devices h Contact The SNMP contact information usually includes an emergency contact name and telephone or pager or Mobile number i Location This string is usually set to the street address where the TRP C34H is physically located Port Settings Page On the Port Settings page of the Server Manager dialog displays
20. erver Admin Utility The Serial Server Admin Utility Support WIN XP VISTA 2003 Server 2008 Server 32 64 bit 2000 Server Win 7 12 Insert the TRP Serial CD find the Serial Server Admin Utility When Installation is completed the wizard creates a Serial Server Admin Utility shortcut on the da Desktop as shown below Serial Server Admin Utility Double Click on the Serial Server Admin Utility then Right click on the main window or go to server Manager in Menu Bar and select Search Devices to find the TRP C34H on the network i Serial Server Admin Utility B E 3m 5 ol x File Function Server Manager View Help server Manager Found 1 Device s a m Ag Model MAC Address IP E Status Server Manager SerialServer4S 00 50 2 18 7 as 3 we Search Devices a aum Lis Add with IP Address Server Monitor Locate 5 96 Te Configure Port Monitor A WebConsole 0 de Fi rade Firmware a Port Mapping Export Configuration Import Configuration mi d assign IP Address Auto IP Address Report Load Factory Defaults Time Description 1 01 01 2002 00 06 23 1 Dewices Found 1 B 1 1 2 41 Unlock OF SernalSernverdS 1 1 1 Event Log x Ready 1 1 2002 OD 0B 27 By default all the devices searched are locked and be seen under the status c
21. hange as per the Hyper terminal session opened Operating mode Click on Operating mode which opens the operating mode page as shown Ibgamatinn Select any port and click on View Settings tab which shows the Operating Mode dialog Box as shown below The default operating Mode is Real Com Mode Note TRP C34H will restart automatically after configuring the Operating Settings page For all other pages TRP C34H will not restart If modify check box is checked to activate the parameter double click or highlight and click Settings tab of the specific port to modify the operating mode Click the Operating Mode 17 drop down box to set the Real Com Mode TCP Server Mode TCP Client Mode UDP Mode as shown below Operating Mode Operating COM Mode d Real COM Mode TCP Server Mode Real COM TCP Client Mode UDP Mode Real COM Mode Key in the TCP Alive Check Timeout to set the timeout for TCP Alive time The Default setting is 7 min TRP C34H automatically closes TCP connection if there is no TCP activity for the given time After the connection is closed TRP C34H starts listening for another REAL COM driver s connection form another host TCP Server Mode a Local TCP Port The TCP Port of TRP C34H that uses to listen to the requests coming from Host Computers on Network in order to establish connection The Host Computers should contact this Port in order to establish connection with the T
22. hanges made to the TRP C34H bnga Piang peswingMode Esci Ps Report Edad ard HEAT Dum rnm dent CANCEL On Auto warning page under E mail and SNMP Trap Setting Tab click the modify box to activate the parameter a On Mail server frame input the IP Address or Domain Name of the Mail server b Input the From E mail Address c Enter the email addresses in the To E Mail address boxes 1 2 3 4 to whom the acknowledgement has to be sent d If the Mail Server has to be authenticated check the Modify box and check the Mail Server authentication check box and then press Setup button 21 e Input the User Name and Password to modify the Mail Server Authentication Setup Mail Server Authentication Setup x User Name Password OK Cancel f set or modify the Trap Server check the Modify checkbox and enter the IP Address or Domain name of the Trap Server to which the Auto warning are to be sent TEE in angi Par Wage Ler E 4484 ma oes On Auto warning page under Event Tab click the Modify box to activate the parameter and click the checkbox to set the Events for which Auto warnings are to be sent curate s iat wey NITET EIC To get Auto Warning E Mails
23. ialServer16S 192 168 3 22 1235 COME 3 SerialServer16S 192 168 3 22 1236 4 SerialServer16S 182 158 3 2 1237 COMB eo 5 Serial amp erver185 192 168 3 22 1244 COMI SESE TOE 6 SerialServeri6S 192 168 3 22 1245 COMI18 85 192 168 3 22 1246 COM22 Ny B SerialServer16S 192 168 3 22 1247 COM23 g Serial amp erver185 192 168 3 22 1254 COMZ24 Port Monitor 10 SerialServer16S 192 168 3 22 1255 COM25 AW 11 Serial5Server165 192 168 3 22 1256 COM2B 52 12 SerialServer16S 192 168 3 22 1257 COM27 13 Serial amp erver185 192 168 3 22 1264 COMZ2B Fort Mapping 14 SerialServer16S 192 168 3 22 1265 29 15 5 165 192 168 3 22 1266 COM3 Ww 3 18 Serial amp erver18S 192 168 3 22 1267 COM31 Auto IF Address Report Ready 1 1 2002 03 36 17 2 5 2 TCP Server Mode TRP C34H TCP Server Mode Null Modem Cable Null Modem Cable OMB Null Modem Cable gt COMC Null Modem Cable COMD PC Host PC Host PC Each Port Maxium Connection 4 Host PC at same time Example Step1 Connect Host PC 1 4 Ethernet TRP C34H PC Step2 Run Serial Server Admin Utility and Right Click on the selected device and click on configure to go to Configuration menu 3 Be sure IP Setting Port Setting and Operating Mode is correct 3 Server Manager ENG Accessible IPs Auto Warning IP Address Report Passwol Basic Settings 1
24. l TCP Port 4003 Connection Misc Optional TCP Alive Check Timeaut 0 99 Inactivit Timeout 65535 ms c Port 4 Setting 38 Operating Mode server Mode Sener TCP Server Mode Settings Local TCP Port 4004 Connection Misc Optional TCP Alive Check Timeout Inactivity Timeout 0 65535 ms Step6 Keep the TRP C34H Server in LAN Also keep the Client PC in LAN Power ON the TRP C34H Server and wait till it completely boots PWR LED ON first otep8 Power ON the TRP C34H Client and wait till it completely boots PWR LED ON Step9 Connect PC COM Port link TRP C34H Client COMA COMD by NULL Modem Cable Step10 Plug in TRP C34H server COMA COMD by DB 9 loop back connector Step11 RUN Demo exe and select correct baud rate and data format 847 Nob DEMO 2 2 1 X A eum De Action Settings COM COMS GOMA Input 00000000 Input 00000000 Input 00000000 Input 00000000 72 put 00000000 Options start Fort DEMO Show Start Look COME Input 000000 End Port 7 Canto 00000000 Output 000000 E jut 00000000 Baud Rate Sue Data Bits Parity stop Bits Flow DTR DSR v RTS CTS otep9 Select
25. n OK CANCEL PoC otep4 Select Port Mapping then right clicks Add Device 26 File Function server Manager Server Monitor He Fort Monitor Fort Mapping View Help Port Mapping 0 Port s Enable Disable IP Address TCP Port COM Number Gs 4 Fort Mapping 6 Port Settings Apply Change Discard Change Auto IP Address Report eg Export Port Mapping xa Import Fort Mapping Step5 The Port Mapping will show below OS File Function 9 Serial Server Admin Utility Port Mapping View Port Mapping 4 Port s Model IP Address TCP Port COM Number 1 Serial amp erverds 192 168 2 22 1234 COMS server Manager Jr 3 6 Serial amp erverds 192 15 2 22 1235 COMB 1 3 SeralServer4s 192 168 2 22 1238 COM 9 4 Serial amp erverds 192 168 2 22 1227 COME server Monitor 2 Port Monitor 4 Gs Port Mapping Auto IP Address Report Ready 1 1 2002 00 24 15 7 otep Right Click select Apply Change 21 9 Serial Server Admin Utility File Function PortMapping View Help Port Mapping 4 Port s a p Model IP Address TCP Part COM Number SearialServer4s 12 4 123 Server Manager um 2 SeralServer wg Add Device 235 COME aia 3 SeralServe 236 COM 9 4 SerialServe Remove Dewice 237 COMS Server Monitor Enable Disable Te Port Settings Fort Monitor ae
26. olumn of the server Manager Window in order to protect from unauthorized configuration changes In order to configure the device it has to be Unlocked first Unlock password trycom After the device has been Unlocked the device can be configured for all Network Serial Operating settings Select the device to be configured Right Click on the selected device and click on configure to go to Configuration menu Double clicking on selected device can also open the Configuration menu 13 E Serial Server Admin Utility 121 File Function Serwer Manager View Help ES server Manager Found 1 Device s LP Al i Model Address 1 IP Address Status Server Manager Search Devices Add with IP Address Locate Unlock Server Monitor Tei Configure This invokes the Server Manager Configuration Dialog as shown below Accessible IFs Auto Warning Address Report Fasswn Basic settings Settings Fort Settings Operating Mad Modify Server Mame Modify Enable Inactivity Time Seconds Modify Time Zone SGMT 05 30 India Local Date Local Time Hr s Mints Sects TimeServer Modify Enable Web Console Enable Telnet Console On Basic page check the Modify check Box to change any of the Configuration details IP Setting 14 Accessible IFs Auto Warning A
27. onnection and data active TX RX LED COMA COMD 5232 422 485 Transiting Receiving Indicator DC Jack Power Input DC 10V to 30V Pleas use the 5 5 2 1mm DC JACK 2 3 Factory default Push the factory restore button till the PWR LED off and then reboot Hardware Setting COMA COMD RS232 Unlock Password trycom Model Name SerialServer 45 Basic configuration Accessible IFs Auto Warning Address Report Fasswn Basic settings Settings Fort settings Operating Mod Modify Server Mame Modify Time Zone GMT 4 05 30 India Local Date 17 1 1970 Local Time Hr s Mints g Sects 1 Modify Enable Web Console Enable Telnet Console IP setting Accessible IFs Auto Warning Address Report Fasswol Basic Settings Settings Fort settings Operating Modify Met Mask Gateway IP Configuration DANS Serverl DAS Server Modify V Enable SNMP Community Name public Location Contact Port Setting Port 1 4 115200bps 8 bit None RS232 Operating Mode Real Com Mode Accessible IPs None Setting Auto Warning None Setting IP Address Report None Setting Password Factory trycom 2 4 DIP Switches There are 4 DIP switch allows the TRP C34H adjust to RS232 or RS422 485 Inside of the box ON RS422 485 OFF RS232 L COM D COM ab
28. r the Network you can centralize Serial Device management and distribute the management to different hosts at the same time TRP C34H makes possible to access distant Serial Devices over Network as if they were directly connected to the Standard COM Port of a Personal Computer TRP C34H supports different modes of operation allowing user to operate the system in different environments Real COM Mode TRP C34H comes equipped with COM drivers that work with Operating Systems WIN 32bit XP Vista 2003Server 2008 Server 82 bit amp 64 bit 2000 Server OS Win 7 32 bit amp 64 bit The driver establishes a transparent connection between host and serial device by mapping the IP Port Number of the TRP C34H s Serial Port to a local COM Port on the host computer The important point is that Real COM Mode allows users to continue using RS 232 422 485 serial communications software like HyperTerminal and similar applications TCP Server Mode In TCP Server mode TRP C34H provides a unique IP Port address on a TCP IP network TRP C34H waits passively to be contacted by the host computer allowing the host computer to establish a connection with and get data from the serial device This operating mode supports up to 4 simultaneous connections so that multiple hosts can collect data from the same serial device at the same time TCP Client Mode In TCP Client mode TRP C34H can actively establish a TCP connection to a pre defined host computer
29. rt 6 8 10 12 14 16 RS 232 422 485 Serial Ports Each Port maximum connection 4 host PC at TCP Server and TCP Client Mode External P1 P2 P3 USB port each port can connect TRP C08S C08U C08H CO08X C29U Maximum allowed bandwidth is 460 Kbps per Serial Port Supports Web Console Telnet Console Runs in Stand Alone Mode Built in Restore Factory default push button Features Accessible Imps List to add or remove legal remote host IP Addresses to prevent unauthorized access to TRP C34H Features Auto IP Address Report to periodically report the IP Address of TRP C34H to the assigned Host on Network Auto direction RS485 flow control by hardware ourge protection and over current and over voltage on RS 422 485 data lines Virtual COM drivers for WIN 32bit XP Vista 2003Server 2008 Server 32 bit amp 64 bit 2000 Server OS Win 7 32 bit amp 64 bit Fully compatible with Ethernet and TCP IP protocol Supports 10 100 Mbps Ethernet Power Link and 4 pair Serial RX TX mode LED indicator Support screw terminal and standard external DC power adaptor i N Din rail or panel mounts support Specification CPU 32 bit 170MHZ with MMU SDRAM 32MB FLASH 8MB Power Input Voltage DC 10V to 30V LAN Auto MDIX 10 100 Mbps Auto detecting RS 232 RI TX RX RTS CTS DTR DSR DCD GND RS 422 TX TX RX RX RS 485 Data Data Data Rate 75 921Kbps Parity none even odd Da
30. ta Bits 5 6 7 or 8 Stop Bits 1 1 5 or 2 Configuration through Windows Admin Utility Web Console Telnet Console Supports Real COM mode using RFC 2217 protocol Protocol ICMP TCP IP UDP DHCP Boot Telnet DNS SNMP HTTP SMTP SNTP External P1 P2 P3 Port each port can be connecting item below 085 USB to 1 RS232 and 1 RS422 485 Isolated Converter TRP CO8H USB to 2 RS232 and 2 RS422 485 Isolated Converter TRP CO08U USB to 4 RS232 Isolated Converter TRP CO08X USB to 4 RS232 422 485 Converter TRP C29U USB to 8 Digital Input and 8 Digital Output Remote Power supply Screw terminal or standard external DC adapter External P1 P2 connector USB Type support power consumption 500mA 5V Serial interface 15 KV ESD RS422 485 interface Surge over current over voltage protection Power consumption 12V 450 mA without external device Operating Temperature 0 to 65 Humidity 0 90 Non Condensing Dimensions 145 L 118 W 26 H mm Weight 728g W Packing 1 3 TRP C34H Support TRP C08X Diagram TRP C34H is a system level solution with four RS232 422 485 serial ports connected to three TR CO08X to support 16 serial port interfaces 8 connected to any of the P1 P2 P3 Ports of TRP C34H to support 8 12 16 Serial Port interfaces Each TRP CO8X can provide four RS232 RS422 RS485 Serial Ports TRP C34H 4 COM 1 Ethernet
31. thorized access to Hosts that are included in this list can only access the TRP C34H on the network Hj eera a 3500000000090 On Accessible IP s page click the modify box to activate the parameter Click on settings button to enter the IP Address and Net Mask of remote host that control the TRP C34H IP Settings X IP Het X Cone You can allow one of the following cases by setting the parameter IP address can access the THP C34H Enter IP gt Only one host of specific address 255 255 255 255 e g 192 168 2 246 255 255 255 255 20 gt Hosts on the specific subnet can access the THP C34H Enter address 255 255 255 0 e g 192 168 2 0 255 255 255 0 gt Any host can access the TRP C34H Disable this function by unchecking the Enable Check Box Refer the following table for more details about the configuration example Allowable Hosts Input format Any host Disable 192 168 2 246 192 168 2 246 255 255 255 255 192 168 2 1 to 192 168 2 254 192 168 2 0 255 255 255 0 192 168 0 1 to 192 168 255 254 192 168 0 0 255 255 0 0 192 168 2 1 to 192 168 2 128 192 168 2 0 255 255 255 128 192 168 2 129 to 192 168 2 254 192 168 2 128 255 255 255 128 Auto Warning Page Auto warning mechanism is a useful mechanism which sends the status messages to E Mail id s and Trap Servers in order to warn or acknowledge the c
32. tings v Model Name SerialServer4s OF Mode TCP Client TCP Client Mode TCP Client Mode TCP Client Mode Address 00 50 C2 18 7F 02 Serial Number E Firmware Version 1 24 15NOV10 View settings settings Click the Modify check box to modify the configuration OK CANCEL a Port 1 Setting 34 Operating Mode Operating Mode TCP Client Made TCP Client TCP Client Mode Settings Connect Mode Start 118 Destination Ho Misc Optional 169 Alive check Timeout 0 99 min Inactivity Timeout 0 65535 ms b Port 2 Setting Operating Mode Operating Client Mode Client TCP Client Mode Settings Connect Mode Start Destination Host Misc Optional Alive check Timeout 0 99 Timeout 0 65535 ms Port 3 Setting Operating Mode Operating Made Client Mode TCP Client TCP Client Made Settings Connect Mode Eten Lp Destination Host Misc Optional TCP Alive check Timeout 0 99 mir Timeout 0 65535 ms d Port 4 Setting Operating Mode Operating Client Mode Client TCP Client Mode Settings Connect Made Start Destination Host Misc Optional TCP Alive check Timeout

Download Pdf Manuals

image

Related Search

Related Contents

Dakota Digital DHC-2000 User's Manual  OPERATOR'S PANEL MT TYPE SERVICE MANUAL  Kramer Electronics VS-1616A audio amplifier  Manual B-Speech Prim Easy(multilingual)  ODAI-WP5-D2 - Open-DAI  EpiNext™ DNA Size Selection Kit  JPRural - Jornal do Povo  Philips Ecomoods Spot light 58018/31/16  einstellen - HERTZ Elektronik GmbH  3M X26  