Home

Maintenance and Operating Instructions SIS 120P

image

Contents

1. f rritro f LS E S r l Via Dell artigianato 1 3 et 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www irritrol it Maintenance and Operating Instructions IRRITROL Pop up sprinkler with integrated valve SIS 120P SISF O f rritro f LS E S r l Via Dell artigianato 1 3 nn 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www irritrol it Contents 1 General 2 Safety 3 Description 4 Assembly 5 Commissioning 6 Maintenance 7 Break down and elimination of the defects 8 Spare parts list 1 General We presume that you are experienced in the field of irrigation Therefore we have kept this instruction as brief as possible and have included such information only which you must have for the use of this product A guarantee can be accepted only if the sprinkler has been operated in accordance with these instructions and if the defect occurs within the guarantee period 1 1 Application The sprinkler is used for the uniform distribution of the water The water should be pre cleaned and free of coarse and fibrous impurities Max water temperature will be 50 degree C Max ambient temperature will be 75 degree C O Irritrol id 3 Via Dell artigianato 1 3 o ili I Gi SISIMu m lt lt cMM MR _x 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www Irritrol it 2 Safety These operation and safety instructions include basic remarks and hints for the
2. gt SS SSS picture 2 7 2 2 Assembly of valve ve Screw the valve insert 12 with the stainless steel 10 onto the valve lifter 32 The chambered surface of the stainless steel must point to the valve insert 12 The valve insert must be greased slightly at the sealing beads 11 and 13 before it is pushed back into the housing v The control drilling between the two sealing beads 13 must point towards the manual control device or ventilating screw during assembly 3 degree or 5mm at the diameter of the sealing beads 11 Push the valve insert 12 into the housing accompanied by slight hits with the sleeve around the valve lifting tool Y Replace the retaining circlip 9 into the groove by using the pliers 30 Make sure that the circlip fits properly If necessary push with the taper at the valve lifter 32 towards the outside 7 2 3 Sprinkler assembly v Place the sprinkler insert with its guide pins 8 in any small groove Press the flange 7 and fasten with screws x Fit housing lid 2 with securing bracket 4 and screws 3 v The sprinkler is now completely assembled Now the function can be checked as described under point 5 1 O Irritrol id 5 Via Dell artigianato 1 3 a 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www Irritrol it 7 3 Break down and elimination of the defects Break down Cause reason Elimination manual not by electrical see point 7 1 24V AC DC c
3. ta cA NA Soy de www irritrol it lt gt ES S Set SS SS ae EEE EE EE EE Eh Ee ee o AE A OP rd A i Bohrungen fiir Steuerwasser holes for control water ae CY I ie ANNIE PSI Ae AA AA rr a rr es LI Al 4 COLLA a a PITT 4 A A ES A A CULLA 4 ra Hydraulikanschluf nur beim LVZR 22 3V Hose tail for LVZR 22 3V Za A rt tetra ii e La Gi p LO Y DIA r PODIA gt T ff da Wav v vY vY prenoti print aie E ell e cn tl stanti O AE OO AE AO O AO E E dad ar De LL am Zylinder Exit for control water Steuerwasserausgang Manuat control ventilating screw Handgesteuert und Entluftungsschraube 18 17 32 30 Irritrol picture 1 O f rritro f LS E S r l Via Dell artigianato 1 3 nnt 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www irritrol it 6 Maintenance ve Clean interior space of the sprinkler with a industrial type vacuum cleaner or a similar device ve Clean relieve sprinkler housing from overgrown grass This work should be done conveniently before commissioning in spring 7 Break down and elimination of the defects 7 1 Disassembly gt Unscrew the screws 3 from the lid 2 Take off lid 2 and securing bra
4. prior notice f rritro f LS E S r l Via Dell artigianato 1 3 lt _ 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www irritrol it Attached SIS 120F SIS 120P without valve O f rritro f LS E S r l Via Dell artigianato 1 3 nn 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www irritrol it Contents 1 Description 2 Installation 3 Commissioning 4 Adjustments 5 Maintenance Cleaning Repair 6 Preparation for winter time 7 Troubleshooting Solutions 8 Disassembly and assembly of sprinklers 1 Description Recommended operating pressure Sto 6 bar Permissible operating pressure 3to 8 bar ATTENTION The pressure at the sprinkler must not exceed 10 bar SIS120 P Sprinkler to impact 30 330 Sprinkler to impact 30 330 with SIS120 PG artificial grass Sprinkler to impact 360 with sod SIS120 F cup for natural turf 11 O Irritrol id 3 Via Dell artigianato 1 3 a 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www Irritrol it 2 Installation Dimension Sprinkler type SIS 120P PG SIS 120F Installation height 370 mm 573mm Rising height 98 mm 205 mm Outer housing 246 mm 246 mm Outer lid 180 mm 242 mm When installation to the public water supply system you must pay attention to the regulations of the water utility respectively guideline of the DVGW Deutscher Verein der Gas und Was
5. valve in head SIS120 PV Sprinkler to impact 307 3307 with valve in head SIS120 PGV Sprinkler to impact 30 330 with valve in head and artificial grass Flush pipe work thoroughly before assembling ATTENTION Threaded connection on the sprinkler is 1 2 female thread For sealing the thread Teflon strip has to be used Installation of the sprinkler should occur according to the Installation layout for PERROT pop up sprinkler LVZR 22 VAC see next side To avoid burden pressure on the conduit pipe use in any rate a sprinkler swing Joint It 1s recommended to assemble a gravel package as shown in the installation layout The connection of the control cables 1s only allowed with approved watertight connections To screw the sprinkler on the swing Joint hold on to the housing border or use a strap wrench Xe xxx x xx O Irritrol id 5 Via Dell artigianato 1 3 a 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www Irritrol it 5 Commissioning Winterise 5 1 1 Connection Measurements Sprinkler type SIS 120PV PGV SIS120FV Installation height 450 mm 660 mm Rising height 99 mm 206 mm Outer housing 246 mm 246 mm Outer lid 180 mm 242 mm 5 1 2 Measurements a b c d e Check of electrical function Before the water supply to the valve is opened the coil has to be triggered through a control unit Through an acoustic click on the coil the corr
6. able connections must be appr ca 30Q not manual defect point 7 1 Exit for control water on Disassembly control pipe cylinder of the valve is out off connection and blocked blow through backwards Valve does not close even Filter for control water is Disassembly valve insert not manual dirty and clean filter or change it see point 7 1 Leakage in the control Check all connections water path control pipe and pressure regulators units for leakage s and eliminate them The pressure on the Valve is blocked Disassembly valve and sprinkler nozzle is too low flush pipes see point 7 1 7 3 1 How to check sprinklers which do not open v Check solenoid in or at the controller for efficient operation ve Engage valve and check at the relief exit of the controller for a brief water splash to come out ve Exchange solenoid at the controller only when there is no pressure in the line 7 3 2 How to check sprinklers which doesn t close y Control line has not been ventilated completely Foreign particles are blocking the valve There is a leak in the hydraulic system The retaining circlip 9 on top of the valve is not fitted correctly and the valve has been pushed out of it s seat by the operating pressure Check the outlet of the solenoid valve for correct functioning To implement this disconnect the control line The valve at the controller is normally open without current X x X Subject to change without
7. assembly installation operation maintenance inspection and repair For this reason these instructions must be read by the fitter as well as by the customers authorised staff prior to the installation and commissioning Apart from the general safety instructions of this paragraph the special safety instructions included in other paragraphs of these operating instructions have to be observed also 2 1 Symbols of hints given in these operating instructions The non observance of the safety instructions mentioned in these operating instructions can endanger persons are marked with the general danger symbol especially Safety instructions which can endanger the sprinkler and its function if not observed are specially marked and the word ATTENTION has been inserted 2 2 Dangers if the safety instructions are not observed Non observance of the safety instructions can endanger persons as well as the environment and the sprinkler Non observance of the safety instructions can result in a loss of all claims for indemnity O Irritrol old 3 Via Dell artigianato 1 3 a 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www Irritrol it 3 Description Recommended operating pressure Sto 6 bar Permissible operating pressure 3 to bar ATTENTION The pressure at the sprinkler must not exceed 10 bar 4 Assembly Sprinkler Valve in Head Sprinkler to impact 360 with sod cup for SIS120 FV natural turf and
8. cket 4 gt Unscrew the screws 6 and pull out the sprinkler insert 5 gt The sheet metal housing with edge 1 can be pulled out for repair or inspection on the electrical parts in case of the pop up sprinkler types LVZR 22 2VDC VAC VDE Disassembly valve piston Before the following mentioned work is carried out it must be sure that the sprinkler is depressurised gt The solenoid 19 can be screwed out with or without the solenoid adapter 18 by turning anti clockwise The filter has to be pulled out for cleaning gt Pull out the retaining circlip 9 with the installation hook 33 Push the installation hook from the left arrow into the bore and turn the installation hook to the left whilst pulling it out again gt Screw the valve lifter 32 into the valve insert 12 Loosen the valve insert 12 by applying slight blows with the sleeve around the lifting tool Pull out the valve insert O Irritrol id 5 Via Dell artigianato 1 3 a 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www Irritrol it 7 2 Assembling of the sprinkler 7 2 1 Flush sprinkler v In case that the valve contains soil particles the sprinkler has to be flushed before assembling ye Assemble flushing equipment 31 in the sprinkler housing see picture 2 and open water supply Connect hose on flushing equipment so that water can be derived Pa Y pS SSS SSS SSSA IS 4 SADA ml I Bii TL Zoro SES
9. ect electrical function can be determined The click arise through attracting the relay armature Open water supply to the sprinkler slowly Probably the valve opens for a short time but after 30 sec it should close on its own After opening the water supply and after the max working operation pressure is reached every seal has to be checked examined Check valves and sprinkler for perfect function when opening the valve manual While operation of the sprinkler there is the possibility to adjust the desired irrigation sector on the spring stop 14 After the complete ventilation of the sprinkler the current supply to the coil must be stopped than the sprinkler has to close 5 2 Winterise x Before beginning of the frost period the sprinkler has to be totally drained off Therefore there must be connected a powerful compressor on the network main circuit Open the valve on the sprinkler until only air is coming out of the nozzle Ix Sprinkler is equipped with a automatic drainage valve and could be winterised by gravity just by drainage the pipe v After the drainage the solenoid has to be activated at least 5 times so that remaining water can be pressed out of the solenoid housing S E S r l Via Dell artigianato 1 3 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 Irritrol Cx x cx 0 4 ta oY y EA ER ta EZ A es mmm 5 de gt 9 ta 4 A ES
10. n of different nozzles and pressures Further information see catalogue 4 3 Jet deflector screw type SIS120P no adjustment available The jet deflector screw is for adjustment of the near irrigation around the sprinkler If you screw in further the screw in the water jet the rainfall consistency around the sprinkler increases the casting range decreases If you unscrew the interruption screw the irrigation around the sprinkler decreases and the casting range increases 5 Maintenance Cleaning Repair To clean or suction the housing you must lift the sprinkler by hand or remove the cover from time to time ye Examine function of gravel package y In case that the sprinkler insert or nozzle head is dirty only clean it with water Do not use lubricants or grease other wise the gliding plate in the sprinkler might be damaged v Please dismount defect parts immediately and repair them or send them to repair 6 Preparation for winter time Before winter the pipe system and the pumping station are to be drained The drainage valve must be open until the next in commissioning By sprinklers with a stop valve H the water above the stop valve cannot discharge itself Because of that reason the sprinkler insert of the installation are to be lift on the cover e g for winterising When the sprinkler insert are lift the water can flows out off the guiding housing and air can enter into the conductions Therefore it is the be
11. serfachm nner e V On stony ground pipes are to be laid in a sand bed The sand bed should surround the pipe everywhere 10 cm Itis necessary that the installation of the pop up sprinkler is in the same level as the ground Under each sprinkler there must be a gravel packing of 3 10 buckets of gravel grading approximately 32 A perfect drainage of the sprinkler housing is very important Coarse gravel Swing joint Main pipe PE connection T piece Flush the pipes proper before installation of the sprinklers 3 Commissioning Pipes must always be filled slowly that means you must open the gate valve gradual under observance of the assigned operating pressure Despite of a thoroughly flushing 1t may happen that the sprinkler nozzle is blocked To clean the nozzle you must turn off the nozzle and flush the sprinkler To unscrew the nozzle you must put a block under the lid or take off the cover Use socket spanner 12 O Irritrol id 3 Via Dell artigianato 1 3 a 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www Irritrol it 4 Adjustments 4 1 Sectors The sectors of the reference part circle of sprinklers are adjusted by pushing the spring stop at the end which expand the spring You achieve a crude adjustment before installation the fine adjustment should be done on the working sprinkler 4 2 Casting range The casting range is regulated through the applicatio
12. st to put a piece of wood with approximately 2 cm between cover and housing until the installation is empty 13 O f rritro f LS E S r l Via Dell artigianato 1 3 A 00065 Fiano Romano RM Tel 076540191 Fax 0765455386 www irritrol it Deckel e cover ic di ee Holzstiick peace of wood Geh use housing Halteventil Stopvalve 7 Troubleshooting Solutions Ww Attention AN Before above mentioned works are executed it must be ensure that the valve is pressure less x Incase of less casting range of some sprinklers it might be garbage in the filter Then you must dismount the sprinkler insert and clean the filter x Flushing the pipe Only with flushing insert otherwise the water which flows back can take garbage with it in the housing and can than enter to the pipe system 8 Disassembly and assembly of sprinklers That work can be done with help of standard tools Disassembly yx Unscrew slot screws in the cover ve Remove screw nut and pull out sprinkler insert Assembly v Tighten sprinkler insert with screw nut Y Mount cover with screws and retainer for cover Subject to change without prior notice 14