Home

FOS 100 POWER USER MANUAL REL 1.2 ENG

image

Contents

1. DMX CHANNEL DMX range Value 000 255 29 NOTES 30 NOTES 31 NOTES 32 The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein MADE IN ITALY CE The Lighting Company ISO 9001 2008 D T S quality system is certified to the ISO 9001 2008 standard D T S products are designed and manufactured at the D T S plants in italy 05171199 D T S Illuminazione s r l Via Fagnano Selve 10 12 14 47843 Misano Adriatico RN Italia Tel 39 0541 611131 Fax 39 0541 611111 infoOats lighting it www dts lighting it
2. FOS 100 POWER SOLO FULL RGBW FOS 100 F 5 Illuminazione s r l ITALY nttp www dts lighting it The Lighting Company Made in Italy Le informazioni contenute in questo documento sono state attentamente redatte e controllate Tuttavia non 6 assunta alcuna responsabilita per eventuali inesattezze Tutti i diritti sono riservati e questo documento non pu essere copiato fotocopiato riprodotto per intero o in parte senza previo consenso scritto della D T S D T S si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche funzionali o di design a ciascun proprio prodotto D T S non assume alcuna responsabilit sull uso o sull applicazione dei prodotti o dei circuiti descritti The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles inexactitudes Tous dro
3. Never locate the fixture on any flammable surface A Minimum distance from flammable materials 10 cm LA Minimum distance from the closest illuminable surface 10 cm 10cm 7 2 Prevention from electric shock AN High voltage is present inside the unit Unplug the unit prior to performing any operation which involves touching the inside of the unit This eguipment must be grounded do not connect to non grounded supplies The use of a thermal magnetic circuit breaker is recommended for each FOS 100 POWER SOLO unit Use only AC supplies 90 260V 50 60 Hz FOS 100 POWER SOLO IP20 should never be located in position exposed to rain or in areas of extreme humidity A good air ventilation is essential for proper eguipment work 7 3 Safety AN The external surface of the unit may exeed 50 ne ver handle the unit until at A least 5 minutes have elapsed since the unit was turned off Never install the unit in an enclosed area lacking sufficient air flow The ambient temperature should not exeed 40 and 5 hould not be lower than 10 11 8 INPUT OUTPUT CONNECTIONS FOS 100 POWER SOLO IP20 am FREE Thi EI M16 LED output DMX IN OUT Female panel connector XLR 5 pins Male Female Panel Connectors Q 65 _ pMXIN DMX OUT ont E avo ung Ba ut S oi 18050 S 4 J SIN a ra MAINS OUT nga Mains 90 260 V AC Mains 90 260 V AC 50
4. DMX channel 12 EDIT channel From 0 19 no function From 20 234 the unit runs the configuration given by the received input DMX values With the channel SCENES it is possible to pass from one step to the next while with REC it is possible to record the selected scene From 235 255 the unit runs the configuration given by the received input DMX values closing the sequence as last scene With the channel REC it is possible to record the selected scene as last scene DMX channel 13 RECORDING channel Records the set scene with a variation between 0 to 255 the display flashes indicating that the scene has been recorded It is advised that you keep the REC channel set to 0 and to run through the 255 only once you have decided to save the scene If ChPr is not closed by indicating the last scene Edit channel between 235 255 in playback mode all 16 scenes will be played through even if not programmed 22 13 DMX PROTOCOL 10 CHANNELS MODE 1 SHUTTER 2 DIMMER 3 RED 4 GREEN 5 BLUE 6 WHITE Sa Pre programmed whites at different colour temperatures 9 COLOURS MACRO 10 FUNCTIONS DMX CHANNEL 1 Parameter SHUTTER STROBE DMX range Mid Point Move Range Mode Option Function Value DMX degrees value 000 009 Black out 010 019 Open 020 029 Black out 030 119 Strobe from 3 27 s to 30 ms 120 149 Pulse up from 42 6 s to 120 ms 150 179 Pulse down
5. Linear control temperature correction 0 2000K 255 7200K 9 Parameter COLOURS MACRO STD Mid Point DMX Move Range Mode Option Function value degrees No Function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 Macro 16 DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 055 056 105 106 155 156 205 206 255 DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 014 015 029 030 044 045 059 060 074 075 089 090 104 105 119 120 134 135 149 150 164 165 179 180 194 195 209 210 225 226 239 240 255 No Function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 Macro 16 Rainbow Speed 1 6 Sec Rainbow Speed 2 15 Sec Rainbow Speed 3 30 Sec Rainbow Speed 4 45 Sec Rainbow Speed 5 60 Sec Rainbow Speed 6 120 Sec Rainbow Speed 7 150 Sec Rainbow Speed 8 180 Sec Random Speed 1 0 5 5 Random Speed 2 1 5 Random Speed 3 2 s Random Speed 4 5 s Random Speed 5 10 s Random Speed 6 30 5 Parameter FUNCTIONS Recall Create and Store the Custom white Function Custom W
6. 03 LB030S 26 FW25 FOS 100 POWER SOLO IP20 FULLWHITE MEDIUM GREY SILVER 03 LB030S 26 FW40 FOS 100 POWER SOLO IP20 FULLWHITE WIDE GREY SILVER 03 LB030S FW10___FOS 100 POWER SOLO IP20 FULLWHITE NARROW BLACK 03 LB030S FW25 7 FOS 100 POWER SOLO IP20 FULLWHITE MEDIUM BLACK 03 LB030S FW40 FOS 100 POWER SOLO IP20 FULLWHITE WIDE BLACK FOS 100 POWER SOLO IP20 FULLRGBW NARROW BLACK FOS 100 POWER SOLO IP20 FULLRGBW MEDIUM BLACK FOS 100 POWER SOLO IP20 FULLRGBW WIDE BLACK FOS 100 POWER SOLO IP20 RGBW NARROW BLACK FOS 100 POWER SOLO IP20 RGBW MEDIUM BLACK FOS 100 POWER SOLO IP20 RGBW WIDE BLACK 03 LB030S F10 03 LB030S F25 03 LB030S F40 03 LB030S T10 03 LB030S T25 03 LB030S T40 03 LB031S 26 FW10 FOS 100 POWER SOLO IP65 FULLWHITE NARROW GREY SILVER 03 LB031S 26 FW25 FOS 100 POWER SOLO IP65 FULLWHITE MEDIUM GREY SILVER 03 LB031S 26 FW40 FOS 100 POWER SOLO IP65 FULLWHITE WIDE GREY SILVER 03 LB031S FW10 FOS 100 POWER SOLO IP65 FULLWHITE NARROW BLACK 03 LB031S FW25 FOS 100 POWER SOLO IP65 FULLWHITE MEDIUM BLACK 03 LB031S FW40 FOS 100 POWER SOLO IP65 FULLWHITE WIDE BLACK FOS 100 POWER SOLO IP65 FULLRGBW NARROW BLACK FOS 100 POWER SOLO IP65 FULLRGBW MEDIUM BLACK FOS 100 POWER SOLO IP65 FULLRGBW WIDE BLACK FOS 100 POWER SOLO IP65 RGBW NARROW BLACK FOS 100 POWER SOLO IP65 RGBW MEDIUM BLACK FOS 100 POWER SOLO IP65 RGBW WIDE BLACK 03 LB031S F10 03 LB031S F25 03 LB031S F40 03 LB031S T10 03 LB031S T25 03 LB031S T40 03 LB031 26 FW10__FOS 100 POWE
7. 2 DIMMER 3 RED 4 GREEN 5 BLUE 6 WHITE DMX CHANNEL 1 Parameter SHUTTER STROBE DMX range Mid Point Move Range Mode Option Value DMX degrees value 000 009 010 019 020 029 030 119 120 149 150 179 180 204 205 229 230 234 235 255 DMX CHANNEL 2 Parameter DIMMER DMX range Mid Point DMX Move Range Mode Value value degrees 000 007 008 255 DMX CHANNEL 3 Parameter RED DMX range Mid Point DMX Move Range Mode Value value degrees 000 255 DMX CHANNEL 4 Parameter GREEN DMX range Mid Point DMX Move Range Mode Value value degrees 000 255 DMX CHANNEL 5 Parameter BLUE DMX range Mid Point DMX Move Range Mode Value value degrees 000 255 DMX CHANNEL 6 Parameter WHITE DMX range Mid Point DMX Move Range Mode Value value degrees 000 255 Option Function Proportional colour Option Function Proportional colour Option Function Proportional colour Option Function Proportional dimmer Option Function Unused Function Black out Open Black out Strobe from 3 27 s to 30 ms Pulse up from 42 6 s to 120 ms Pulse down from 42 6 s to 120 ms Random strobe Dimmer channel active Full independent Random Strobe Dimmer channel disabled Red Yellow Cyan and Blue colour effects at variable speed Open 26 WALL MODE GREEN RED BLUE DIMMER NOT USED SHUTTER DUO
8. REC channel set to 0 and to run through the 255 only once you have decided to save the scene If ChPr is not closed by indicating the last scene Edit channel between 235 255 in playback mode all 16 scenes will be played through even if not programmed he 10 channels necessary to control the unit Liu ur E 5L RU ES Urt IE ER 5 LIS enter SLAVE MODE 7 Slave mode for ChPr program All slave units will be synchronised with master unit running their own Chpr program MENU Up Down r ENTER Up Down Lift ENR INFRARED MODE NOTE External infrared remote Infrared remote control sensor needed By activating Ir MODE it will be possible to navigate D T S Code 03 LA 016 through the unit functions by using the D T S infrared remote control D T S Code 0514L008 is Is FAn IS mE ieu ES FAN SPEED CONTROL n Ff Internal Fan Speed control selectable by user Range OFF 24 volt Default 24 volt IS IS CNC ss SEL EMERGENCY Ener SB IS R Un 3 Emergency operating mode nre By setting Emergency mode it will be possible to select ure Default OFF one of the 16 preprogrammed WHITE cues that will then ran if DMX signal is missing or IS Default White 1 not available Gil Useful for Emergency EXIT illumination on d nn Default 255 ENTER public areas 20 12 SERVICE MENU For technical personnel only
9. To operate this menu Connect the unit to the main While reset is running press the MENU and ENTER keys at the same time CHANNELS This menu allow to set 3 channels or 4 channels LEDs output mode 3 LEDs channels output mode Not Used on FOS 100 POWER SOLO 4 LEDs channels output mode Default Pr Bd PRODUCT MODEL SELECTION FOS 100 POWER Default TITAN PLUS only for TITAN PLUS unit DELTA 8 only for DELTA 8 unit ESC EXIT Exit from hidden menu AUTOMATIC OPERATION AUTO FOS 100 POWER SOLO can work in automatic mode without a DMX controller First of all connect the projectors with a DMX cable picture below A maximum quantity of 32 slave units can be connected to the same Master unit SLAVE 2 SLAVE 32 MASTER SLAVE 1 To activate Auto mode on the first unit use the menu to run through the different modes until AUTO appears on the display and press enter Now it is possible to choose between the different pre programmed games CUPr RAln CU01 CU16 Wh01 Wh16 or ChPr which is user programmable through REC mode To confirm game activation press ENTER on the selected GAME CUPr RAln CU01 CU16 Wh01 Wh16 The first unit that will work as a Master should be placed in Automatic mode AUTO the other units have to be placed 10 channels DMX mode MODE 10 CH and the DMX address should be set at A001 For Raln rainbow game it is possible to select the speed for the colour changhing SPEE DIMMER function in
10. address 10 FIRMWARE UPDATING 11 DISPLAY FUNCTIONS 12 SERVICE MENU 13 DMX PROTOCOL 1 SYMBOLS Graphic symbols used on this manual THIS SYMBOL INDICATES A HOT SURFACE THIS SYMBOL INDICATES ELECTRIC SHOCK RISK THIS SYMBOL INDICATES GENERAL RISK THIS SYMBOL MEANS DO NOT PLACE THE UNIT ON INFLAMMABLE SURFACES A A A A THIS SYMBOL INDICATES THE MINIMUM DISTANCE TO BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT CN EA O O 3 2 GENERAL WARNING Read the instruction contained in this user manual carefully as they give important information regarding safety during installation use and maintenance The device is not for domestic use and must be installed by a qualified electrician or experienced person Always disconnect the device from the mains before maintenance The device must always be equipped with an efficient ground connection 3 GENERAL WARRANTY CONDITIONS The unit is guaranteed for 36 months from the date of purchase against manufacturing material defects 4 TECHNICAL FEATURES OVERVIEW FOS 100 POWER is the most powerful model in the FOS line of compact LED bars designed for lighting and colouring large surfaces with a homogeneous projection FOS 100 POWER is ideal in a variety of applications either indoor or outdoor such as lighting building facades monuments public and commercial spaces creating uniform background colours and cycloramas etc FOS 100 POWER is available in t
11. and set the following addresses on the mixer Projector 1 1 Projector 2 1 you want to select the next projector just add 10 Projector 3 1 Paba Acne projector6 A051 If you want to use the FOS 100 POWER SOLO in WALL mode select the WALL mode from the MODE menu and set the following addresses on the mixer To be used only with DTS Wall mounted DMX controller 0514L007 If you want select the next projector just add 8 A001 i 5 DTS Wall mounted DMX controller 05141 007 assign Projector 3 A017 8 DMX channels per unit even if some channels are aba As not used projector A041 9 2 Selecting the DMX address 1 Press the UP DOWN key until you reach the reguired DMX address The numbers on the display will start to flash but the new DMX address hasn t yet been set 2 Press ENTER to confirm your selection The numbers on the display will stop flashing and the projector is now controlled by the new DMX address TIPS if you keep pushed the UP or DOWN keys the channels are calculated more quickly and you get a faster selection 15 10 FIRMWARE UPDATING Warning This procedure require a base knowledge of Windows computer applications Please refer to an authorised D T S service centre To update the software version of the FOS 100 POWER SOLO you need D T S RED BOX interface D T S Code 03 LA 008 USB DMX Driver for the D T S RED BOX interface D T S Firmware upgrade utility prog
12. from 42 6 s to 120 ms Random strobe 180 204 Dimmer channel active Full independent Random Strobe 205 229 Dimmer channel disabled 230 234 Red Yellow Cyan and Blue colour effects at variable speed 235 255 Open DMX CHANNEL 2 Parameter DIMMER DMX range Mid Point DMX Move Range Mode Option Function Value value degrees 000 007 Black out 008 255 Proportional dimmer DMX CHANNEL 3 Parameter RED DMX range Mid Point DMX Move Range Mode Option Function Value value degrees 000 255 Proportional colour DMX CHANNEL 4 Parameter GREEN DMX range Mid Point DMX Move Range Mode Option Function Value value degrees 000 255 Proportional colour 23 5 Parameter BLUE Mid Point DMX Move Range Mode Option Function value degrees Proportional colour 6 Parameter WHITE Mid Point DMX Move Range Mode Option Function value degrees Proportional colour 7 Parameter WHITE PREPROGRAMMED White at diff colour temperature Mid Point DMX Move Range Mode Option Function value degrees 23 No Function Full Red Green 80 Blue at Full 130 White DTS Custom White 180 Create RGB levels selectable by DMX White CTC 230 Channel 15 CTC enabled 8 Parameter CTC Colour Temperature Correction Mid Point DMX Move Range Mode Option Function value degrees
13. 5 ms Instant response to DMX variation 20 250 ms Smooth response to DMX variation Linear Linear current output ENTER ce 3 e Quadratic Linear light output ENTER O ES OL Range O 610Hz 10kHz IS Default 610 0 Boost mode activated ENTER 0 Boost mode deactivated IS 3 With BOOST active the LED s current is set to 500mA 30 more gain Default Activated ER UE Up Down ENTER Up Down ENTER Up Down ENTER Up Down ENTER Up Down ENTER Up Down ENTER Up Down Up Down 17 Up Down 8 6 i TT Up Down gt bLuE Up Down gt 57 A Since Snc m 5 ce SS LU ET Up Down LC d ENTER LED RGBA Min Max Smooth and Compression levels values settings RGBA MINIMUM VALUES This menu allow to select the minimum levels for Red Green Blue and RGBA MAXIMUM VALUES This menu allow to select the maximum levels for These settings have priority on Master Dimmer SMOOTH VALUE This menu allow to select the value of the delay in milliseconds for RGB and Dimmer channels reaction to DMX or Program variation Off 25 ms delay Fast response 20 250 ms delay Slow response COMPRESSION This menu allow to select between Linear courrent output or Quadratic courrent output for LEDs Default Linear BOOST DRIVING This menu allow to increase the LED s current from 350mA to 500 mA MEN
14. 60 Hz input Powercon 50 60 Hz output Powercon Female panel connector Female panel connector MAX load 230 V AC 10 FOS 100 POWER SOLO MTG LED input 100 V AC 5 FOS 100 POWER SOLO Male cable connector LED OUTPUTS M16 Female M16 Male WIRES SEQUENCE PIN OUT panel connector cable connector COLOURS PIN 1 BLUE PIN 1 RED PIN 2 GREEN PIN2 GREEN PIN3 BLUE PIN 3 YELLOW PIN4 WHITE PIN 4 ORANGE COMMON PIN 5 RED RED PIN 6 BROWN PIN 7 BLACK BLUE PIN 8 GREY WHITE PIN 9 WHITE NTC THERMAL PIN 9 NTC SENSOR Front View Front View 12 FOS 100 POWER IP65 M16 LED input Male cable connector LED OUTPUTS M16 Female M16 Male WIRES SEQUENCE PIN OUT panel connector cable connector COLOURS PIN 1 RED PIN 1 BLUE PIN 2 GREEN PIN2 GREEN PIN3 BLUE PIN3 YELLOW PIN4 WHITE 4 ORANGE PIN5 COMMON PIN 5 RED RED PIN 6 BROWN PIN 6 GREEN PIN 7 BLACK PIN 8 GREY PIN 7 P PIN 9 WHITE PIN 8 NTC Pg PIN 9 NTC SENSOR Front View Front View 13 9 DMX SIGNAL CONNECTION FOS 100 POWER SOLO The unit operates using a digital DMX 512 signal Connection between the controller and the unit or between units must be carried out using a two pair screened g 0 5 mm Ensure that the conductors do not touch each other Do not connect the cable ground to the DMX connector chassis The plug housing must b
15. AUTOMATIC MODE is active for all the programs 21 SHUTTER function in AUTOMATIC MODE is active only for CU01 CU16 and Wh01 Wh16 macros ChPr MASTER SLAVE The first unit that will function as a Master must be set to Automatic mode AUTO the other units must be set to Slave mode SLAV selectable through the menu In this way all the Slave units will be synchronised with the master and running their own ChPr game On the master unit it is possible to vary the Speed time SPEE for the colour changhing and the Wait time UAIt between the steps Speed time and Wait time on the Master have priority on the slave units NB It is possible to run GA Pr on the other units even though these do not have GA Pr programmed You can do this by setting the units to 10 channels DMX mode and selecting DMX address A001 REC MODE It is possible to program your own game on the FOS 100 POWER SOLO that will then run it in AUTO mode ChPr Each unit can have its own programmed game In REC mode the unit must be set to 10 channels mode To program the ChPr by using a DMX controller you need 3 more channels in addition to the 10 channels necessary to control the unit So that in RECORDER mode via DMX the unit will need 13 DMX channels to be correctly programmed The three new DMX channels are DMX channel 11 SCENES channel From 0 24 no function From 25 255 the programmable scenes are displayed max 16 scenes from M001 to M0016
16. N DMX CHANNEL 1 Parameter GREEN DMX range Mid Point DMX Move Range Mode Value value degrees 000 255 DMX CHANNEL 2 Parameter RED DMX range Mid Point DMX Move Range Mode Value value degrees 000 255 DMX CHANNEL 3 Parameter BLUE DMX range Mid Point DMX Move Range Mode Value value degrees 000 255 DMX CHANNEL 4 Parameter DIMMER DMX range Mid Point DMX Move Range Mode Value value degrees 000 255 DMX CHANNEL 5 Parameter NOT USED DMX range Mid Point DMX Move Range Mode Value value degrees 000 255 DMX CHANNEL 6 Parameter SHUTTER STROBE DMX range Mid Point Move Range Mode Option Value DMX degrees value 000 009 010 019 020 029 030 119 120 149 150 179 180 204 205 229 230 234 235 255 Function Proportional dimmer Function Proportional colour Function Proportional colour Function Proportional colour Function Proportional colour Option Option Option Option Option Mode Mode Mode Mode Mode 27 5 CHANNELS MODE M4CH 1 Parameter DIMMER Mid Point DMX Move Range value degrees 2 Parameter RED Mid Point DMX Move Range value degrees 3 Parameter GREEN Mid Poin
17. R IP65 FULLWHITE NARROW GREY SILVER 03 LB031 26 FW25 FOS 100 POWER IP65 FULLWHITE MEDIUM GREY SILVER 03 LB031 26 FW40 FOS 100 POWER IP65 FULLWHITE WIDE GREY SILVER FOS 100 POWER IP65 FULLWHITE NARROW BLACK FOS 100 POWER IP65 FULLWHITE MEDIUM BLACK FOS 100 POWER IP65 FULLWHITE WIDE BLACK 03 LB031 FW10 03 LB031 FW25 03 LB031 FW40 FOS 100 POWER IP65 FULLRGBW NARROW BLACK FOS 100 POWER IP65 FULLRGBW MEDIUM BLACK FOS 100 POWER IP65 FULLRGBW WIDE BLACK FOS 100 POWER IP65 RGBW NARROW BLACK FOS 100 POWER IP65 RGBW MEDIUM BLACK FOS 100 POWER IP65 RGBW WIDE BLACK 03 LB031 F10 03 LB031 F25 03 LB031 F40 03 LB031 T10 03 LB031 T25 03 LB031 T40 5 MAIN ELECTRICAL CHARACTERISTICS FOS 100 POWER SOLO Input Voltage Range Vin 90 260 Vac Frequency 50 60 Hz Power Consumption Range 10 200 W Power Factor Pf 0 95 electronic PFC controller Efficiency 90 typical Control Input Control Signal DMX 512 Dimming System Constant Current PWM Address Range DMX 512 channels addressable by display 6 ACCESSORIES As standard IP20 1 x User s Manual 1 POWERCON IN male cable connector FOS 100 POWER SOLO D T S Code 0520P014 1 x POWERCON OUT male cable connector FOS 100 POWER SOLO D T S Code 0520P029 1 x XLR 5 poles male cable connector D T S Code 0508B028 1 XLR 5 poles female cable connector D T S Code 0508B027 1 x Joint spacer D T S Code 00M09519 46 black finish 00M09519 44 grey
18. U ENTER LI 8 m 2 IS ENTER 18 8 o 5 5 3 C3 C3 J Do o 6 Co 6 LI a R ENTER a C r ES m Mu Col un C3 Un zB 3 o E Is Up Down 8 o 3 8 m NT un ENTER c do 5 5 5 ENTER ENTER r 6 C Es CI Nu x C3 E ENTER Up Down ENTER E CI ES zc CI NU E lt CI Y un 6 CI CS X ES pa ng eh IS ENTER 2 IS ENTER a O Up Down 057 SHUEJS is ENTER IS ENTER Up Down m un cq ILO IS ZII IS IS Butt ENTER Sur 6 ENTER Up Down is IS MENU Up Down AUTOMATIC MODE Automatic demo game without DMX controller ChPr Chase with 16 steps previously created in REC MODE Speed and Wait time selectable by user CUPr RGB values selectable by user Rainbow rAln Rainbow colours effect Speed time selectable by user CU01 CU16 Color Macros as on DMX channel 8 Macro WHITE MACROS 16 macros for White color from 2800 to 6500 K DIMMER Dimmer tevet selectable by user as on DMX channel 2 Dimmer Dimmer level is active for all the programs and macros SHUTTER Shutter l
19. e isolated Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first unit to the DMX IN plug of the second one In this way all the projectors are cascade connected CONTROLLER STANDARD DMX 512 Ag gt 1 GND 2 DATA 4 02 3 DATA 3 If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX terminator is a male XLR 3 5 pins connector with a 120 ohm resistor Between pin 2 and 3 The DMX terminator must be plugged into the last unit DMX out panel connector of the DMX line PLACE A 120 OHM RESISTOR BETWEEN PIN 2 AND 3 OF A MALE XRL CONNECTOR AND PLUG IT INTO THE DMX OUT PANEL CONNECTOR OF THE PIN 3 LAST UNIT CONNECTED TO THE DMX LINE PIN 2 14 9 1 DMX addresses FOS 100 POWER SOLO all models can be used in seven different modes 10 DMX channels mode default 6 DMX channels mode Shutter Dimmer RGBW WALL mode 6 DMX channels for use with DTS Wall mounted DMX controller 0514L007 M4CH mode 5 DMX channels Dimmer RGBW RGBW mode 4 channels 1 DMX channel mode or CUSTOM DMX mode not yet implemented If you want to use the FOS 100 POWER SOLO in 10 channels mode select the 10 CH mode from the MODE menu
20. evel selectable by user as on DMX channel 1 Shutter Shutter level is active only for CU01 CU16 and Wh01 Wh16 macros ESC Esc from Automatic Mode Menu mum 08 EOF REC MODE In DMX Recorder Mode it is possible to create and store the scenes of the ChPr by using an ngge external DMX controller The unit must be setted to 10 channels MODE NG 15 DMX Recorder Mode For the programming of ChPr by using a DMX controller besides a further 3 DMX channels are needed So that in RECORDER mode via DMX the unit will need 13 channels to be correctly programmed The three new DMX channels are DMX channel 11 SCENES channel From 0 10 no function r001 From 11 255 are displayed the programmable scenes max 16 scenes from M001 to M0016 DMX channel 12 EDIT channel From 0 19 no function From 20 234 the unit runs the configuration given by the received input DMX values With the channel SCENES it is possible to pass from one step to the next while with REC it is possible to record the selected scene From 235 255 the unit runs the configuration given by the received input DMX values closing the seguence as last scene With the channel REC it is possible to record the selected scene as last scene DMX channel 13 RECORDING channel Records the set scene with a variation between O to 255 the display flashes indicating that the scene has been recorded lt is advised that you keep the
21. finish with 2 knobs D T S Code 0511P014 As standard IP65 1 x User s Manual 1 x HARTING 5 poles male cable connector D T S Code 02LD0093 1 1 x Joint spacer D T S Code 00M09519 46 black finish 00M09519 44 grey finish with 2 x knobs D T S Code 0511P014 Optional on reguest Lenses set Spot FOS 100 POWER FULLCOLOUR D T S Code 03 LK 107 Lenses set Medium flood FOS 100 POWER FULLCOLOUR D T S Code 03 LK 108 Lenses set Wide flood FOS 100 POWER FULLCOLOUR D T S Code 03 LK 109 Lenses set Medium flood FOS 100 POWER RGBW D T S Code 03 LK 114 Lenses set Wide flood FOS 100 POWER RGBW D T S Code 03 LK 115 G60 6 Clamp Max load 50 Kg Black D T S Code 0521A004 G50 Clamp Max load 10 Kg Black D T S Code 0521A012 M16 female 9 poles cable connector D T S Code 0508B106 M16 male 9 poles cable connector D T S Code 0508B105 240 Power supply LED controller FOS 100 POWER D T S Code 03 LA 120 Packing Dimensions LxWxH 1060 x 160 x 200 mm Weight 8 5 Kg DIMENSIONS FOS 100 POWER SOLO Unit Dimensions LxWxH 990 100 84 5 mm Weight 7 Kg O 0 0 0 0 0 0 6 6 O Packing Dimensions LxWxH 1060 x 160 x 200 mm Weight 7 Kg 0 e e 7 0 0 0 O O 6 e FOS 100 POWER Unit Dimensions LxWxH 990 x 56 x 84 5 mm Weight 5 5 Kg 10 7 IMPORTANT SAFETY INFORMATION 7 1 Fire prevention
22. hite Recall Custom White Create Enable Custom White Creation Custom White Store Store the Custom White created Option e value 156 205 Parameter COLOURS MACRO EXT Mode 24 Move Range degrees 10 Mid Point DMX value IF CHANNEL 7 WHITE PREPROGRAMMED DMX ran DMX CHANNEL 000 014 015 022 023 030 031 038 039 046 047 054 055 062 063 070 071 078 079 086 087 094 095 102 103 110 111 118 119 126 127 134 135 142 143 504 151 158 159 166 167 174 175 182 283 190 191 198 199 206 207 214 215 222 223 230 231 238 239 246 247 255 DMX CHANNEL DMX range Value 000 079 080 160 161 255 Function Black out Open Black out Strobe from 3 27 s to 30 ms Pulse up from 42 6 s to 120 ms Pulse down from 42 6 s to 120 ms Random strobe Dimmer channel active Full independent Random Strobe Dimmer channel disabled Red Yellow Cyan and Blue colour effects at variable speed Open Option Function Black out Proportional dimmer Option Function Proportional colour Option Function Proportional colour Option Function Proportional colour Option Function Proportional colour 25 6 CHANNELS MODE 1 SHUTTER
23. its r serv s Ce document ne peut tre copi photocopi ou reproduit dans sa totalit ou partiellement sans le consentement pr alable de D T S D T S se r serve le droit d apporter toutes modifications et am liorations esth tiques fonctionnelles ou de design sans pr avis chacun de ses produits D T S d cline toute responsabilit sur l utilisation ou sur l application des produits ou des circuits d crits Las informaciones contenidas en este documento han sido cuidadosamente redactadas y controladas Con todo no se asume ninguna responsabilidad por eventuales inexactitudes Todos los derechos han sido reservados y este documento no puede ser copiado fotocopiado o reproducido total o parcialmente sin previa autorizaci n escrita de D T S D T S se reserva el derecho a aportar sin previo aviso cambios y modificaciones de car cter est tico funcional o de dise o a cada producto suyo D T S no se asume responsabilidad de ning n tipo sobre la utilizaci n o sobre la aplicaci n de los productos o de los circuitos descritos lo lo 11 13 15 16 20 22 1 SYMBOLS 2 GENERAL WARNING 3 GENERAL WARRANTY CONDITION 4 TECHNICAL FEATURES 5 MAIN ELECTRICAL CHARACTERISTICS 6 ACCESSORIES 7 IMPORTANT SAFETY INFORMATION 7 1 Fire prevention 7 2 Prevention of electric shock 7 3 Safety 8 INPUT OUTPUT CONNECTIONS 9 DMX SIGNAL CONNECTION 9 1 DMX Addresses 9 2 Selecting the DMX
24. nnector Standard mode gt es enabled Default Extended mode enabled ERE BS ever Rainbow effects on MACRO channel ENTER Up Down function Software version 4 0 7 ISP d REVERSE DISPLAY ome wo MENU Up Down Reverses display s reading depending Up Down EE or on the mounting position On the ground or suspended DISPLAY STAND BY To turn off the display after 5 seconds IS Up Down Up Down Up Down or leave it always on d t ENTER MENU Up Down DMX MODE To select DMX mode 10 DMX channels mode default 6 DMX channels mode Shutter Dimmer RGB WALL mode 6 DMX channels for use with DTS Wall mounted DMX controller 0514L007 M3CH mode 4 DMX channels Dimmer RGB RGB mode 4 channels 1 DMX channel mode AUX mode let you activate an external ON OFF control on IR connector CUSTOM DMX mode let you set the parameters for Shutter Dimmer Red Green Blue Ctc Macro and Function to the desired DMX channels not yet implemented MACRO Function enables channel mapping macro rainbow effects STD default I 1 Default 0 Default 100 RS Default 0 lt a Default 100 MES 3E Default 0 al Sa 3 5 Default 100 ID 2 LL LJ Range Off 20 Default 4 ENTER Off 2
25. ram The driver and the installation procedure are available in our web site www dts lighting it Updating the software version Please follow the procedure below to perform the update 1 Install the D T S RED BOX USB DMX driver on the PC you will use to update the unit software 2 Connect the D T S RED BOX interface to the PC by using a USB cable 3 Connect the D T S RED BOX interface to the fixture by using a DMX cable 4 Download the new software version into the unit by using D T S Firmware upgrade utility program 16 11 DISPLAY FUNCTIONS The FOS 100 POWER SOLO display panel shows all the available functions Using these functions it is possible to change some of the parameters and add some functions Changing the D T S setting can vary the functions of the unit so that it does not respond to the DMX 512 signal used to control it Carefully follow the instructions below before carrying out any variations or selections NOTE the symbol 13 shows which key has to be pushed to obtain the desired Is Floor ENTER sus CAR EEB Position Suspension pa Display Always ON IS Default DMX Mode 10 CH ENTER ENTER ENTER r Gb 2 RGBA 4 CHANNELS ES GEH 6cHANNELSs BF H M4cH 5 CHANNELS RGBA CUSL x is ES Custom mode enabled IS Show Custom settings SEE lt gt Parameters Setting ENER Custom Mode ALIHI AUX move ES External ON OFF control on IR co
26. t DMX Move Range value degrees 4 Parameter BLUE Mid Point DMX Move Range value degrees 5 Parameter WHITE Mid Point DMX Move Range value degrees DIMMER GREEN RED BLUE WHITE UPON DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 255 Function Proportional colour Function Proportional colour Function Proportional colour Function Proportional colour Function Proportional dimmer Option Option Option Option Option Mode Mode Mode Mode Mode 28 4 CHANNELS MODE RGBW 1 Parameter RED Mid Point DMX Move Range value degrees 2 Parameter GREEN Mid Point DMX Move Range value degrees 3 Parameter BLUE Mid Point DMX Move Range value degrees 4 Parameter WHITE Mid Point DMX Move Range value degrees 1 Parameter DIMMER Mid Point DMX Move Range value degrees GREEN RED BLUE WHITE BON gt DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 255 DMX CHANNEL DMX range Value 000 255 1 CHANNEL MODE 1CH 1 DIMMER
27. wo versions FOS 100 POWER FULL COLOUR 24 x Full Colour RGBW LEDs FOS 100 POWER RGBW 96 x RGBW LEDs Three dedicated lenses sets Spot Medium flood Wide flood are available for each model LED Technology FOS 100 POWER FULL COLOUR 24 Full Colour RGBW LEDs 7 028 Lux at 3 m 16 million colours linear colour temperature 2800 K 6500 K FOS 100 POWER RGBW 96 x RGBW LEDs 24 x Red 24 x Green 24 xBlue 24 x White 10 528 Lux at 3 m 16 million colours linear colour temperature 2800 K 6500 K No infrared emission no ultraviolet emission LEDs average lifespan 100 000 hours Optical group 3 lenses sets available Spot Medium flood Wide flood Control Via any DMX lighting console FOS 100 POWER SOLO Protection IP65 protection level against the penetration of solids and liquids Construction FOS units are made on aluminium and steel Connections M16 male connector cable length 30 cm connection system between Power supply and LED bar All versions POWERCON XLR 5 poles cable connectors FOS 100 POWER SOLO IP20 HARTING 5 poles cable connector FOS 100 POWER SOLO IP65 Power supply Electronic full range power supply AC 90 260V 50 60 Hz Integrated power supply LED controller FOS 100 POWER SOLO 210 POWER IP20 or 210 POWER IP65 External dedicated 240 power supply LED controller FOS 100 POWER Product codes 03 LB030S 26 FW10 FOS 100 POWER SOLO IP20 FULLWHITE NARROW GREY SILVER