Home
FOS 100 DYNAMIC FULL RGBW User manual rel 2.1
Contents
1. 100 DYNAMIC DMX OUT 14 ILME 4 pins Female Panel Connectors MAINS OUTPUT FEMALE PANEL DMX IN OUT CONNECTOR FEMALE PANEL L CONNECTOR N 2 3 DATA DATA M12 5 PINS LED input M12 5 PINS LED output LEDS Male cable connector Female panel connector CONNECTOR PINOUT 1 DMX DATA 3 2 2 3 2 GROUND 3 DMX DATA 4 24V DC AN 41 ib 4 5 HEARTH 5 5 8 FOS 100 DYNAMIC DMX SIGNAL CONNECTION FOS 100 DYNAMIC IP20 The unit operates using a digital DMX 512 signal Connection between the controller and the unit or between units must be carried out using a two pair screened 0 5 mm Ensure that the conductors do not touch each other Do not connect the cable ground to the DMX connector chassis The plug housing must be isolated Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first unit to the DMX IN plug of the second one In this way all the projectors are cascade connected CONTROLLER STANDARD DMX 512 5 1 Pa 1 GND a 2 DATA 4 XIZ 2 3 DATA 3 P S If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX terminator is a male XLR 3 5 pins connector with a 120 ohm resistor Between pin 2 and 3 The DMX terminator must be
2. 180 204 192 Random Strobe Master and RGBW active 205 229 218 Random Strobe Full 230 255 240 Open DMX CHANNEL Parameter DIMMER mmm Move BANIDO reng range Mode Option Function Value Se a 0 255 Proportional dimmer _ IH Move DAMA range range Mode Option Function Value AA 0 255 Proportional colour 19 FOS 100 DYNAMIC NON Move Value degrees 0255 Proportional colour ITEM Move LAMA range range Mode Option Function Value degrees ENE Nge gang 0255 Proportional colour EN Move DMX range range Mode Option Function Value degrees nn 0255 Proportional colour Value degrees 000 047 M3 __ NOEFFECTO ___ 048 063 056 Background 064 079 070 HystogramLet 080 095 087 HystogramBight 096 111 104 Hystogram Multicolor Left 112 127 120 HystogramMulticolorRight 128 143 136 ContinousShiftRight 144 159 152 Continous ShiftLeft 160 175 168 ave Right 176 191 184 ave eft 192 207 200 RandomStrobo Random Strobo Random Colour _ 224 239 232 Pulse IN 240 255 247 Z Random Pick OG DMX CHANNEL EN Parameter COLOUR 1 Move range Function 208 223 215 __ Random Strobo Random Colour DMX range Value degrees 0255 Colour Selection 20 FOS 100 DYNAMIC INN Move Value degr
3. in grey silver finish LED technology 15 x FULL RGBW LEDs 6720 Lumens 16 million colours linear colour temperature 2700K 8000K 16 selectable types of White LEDs average lifespan 75 000 hours 70 lumen output Optical units 3 lenses sets available Spot Medium flood Wide flood Control DMX 512 Protection IP20 or IP65 protection level against the penetration of solids and liquids Construction FOS 100 DYNAMIC is made on extruded aluminium Power supply Electronic full range 90 260Vac 50 60 Hz Power consumption 150W Max Operating ambient temperature 10 40 Weight 6 5 Kg 4 FOS 100 DYNAMIC IMPORTANT SAFETY INFORMATION Fire prevention It is permissible to place the unit on normally flammable surfaces Suitable for mounting on normally flammable materials surfaces greater than 200 C with some combustion time lag Prevention from electric shock High voltage is present inside the unit Unplug the unit prior to performing any operation which involves touching the inside of the unit This equipment must be grounded do not connect to non grounded supplies The use of a thermal magnetic circuit breaker is recommended for each unit Use only AC supplies 90 260V 50 60Hz The unit should never be located in position exposed to rain or in areas of extreme humidity A good air ventilation is essential for proper equipment work Safety The external surface of the unit may exeed 50 C never handle t
4. or 60 CH8 CTC CH9 MACRO DMX channels default CH10 FUNCTION s IF Default DMX Mode 60 CH ENTER ES 60 CHANNEL CH1 RED CH2 GREEN tasso 4 CHANNELS IS CH3 BLUE CH4 WHITE IS CH1 lt SHUTTER CH2 lt DIMMER ENTER CH3 RED CH4 GREEN CH5 BLUE CH6 AMBER CH7 EFFECT1 CH8 COLOURI CH9 PARAM1 CH O LEVEL1 CH11 EFFECT2 CH12 COLOUR2 CH13 PARAM2 Ch14 LEVEL2 14 CHANNELS Up Down 12 FOS 100 DYNAMIC IS IS IS IS L I Standard mode enabled MENU Up Down ENTER Up Down LL Le Default MACRO MACRO Function enable channel H i A Show Custom settings mapping macro rainbow effects STD default IF IS IS IS MENU Up Down ENTER Up Down LED RGBW Min Max Smooth Compression Sync and Boost level values settings Default lt 0 ENTER Up Down Default lt 100 ENTER RGBW MINIMUM VALUES Default lt 0 This menu allow to select the Up Down minimum levels for Red Green Blue and White ENTER Up Down y Default 100 m A m ZU RGBW MAXIMUM VALUES This menu allow to select the Tu E y mr m ITI A maximum levels for Red Green ENTER Up Down oa 4 Blue and White ee These settings have priority Default 100 ES E ENTER on Master Dimmer channel Default O IS SMOOTH VALUE Up Down ENTER Up Down ENTER This menu allow to select the value of the delay in milliseconds for RGB and Dimmer channels Default 100 IS reaction to D
5. plugged into the last unit DMX out panel connector of the DMX line PLACE A 120 OHM RESISTOR BETWEEN PIN 2 AND 3 OF AMALE XRL CONNECTOR AND PLUG IT INTO THE DMX OUT PANEL CONNECTOR OF THE LAST UNIT CONNECTED TO THE DMX LINE PIN 3 PIN 2 The standard configuration of the FOS 100 DYNAMIC is with XLR 5 pins connectors 9 FOS 100 DYNAMIC DMX SIGNAL CONNECTION FOS 100 DYNAMIC IP65 The unit operates using a digital DMX 512 signal Connection between the controller and the unit or between units must be carried out using a two pair screened 0 5 mm Ensure that the conductors do not touch each other Do not connect the cable ground to the DMX connector chassis The plug housing must be isolated Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first unit to the DMX IN plug of the second one In this way all the projectors are cascade connected CONTROLLER STANDARD DMX 512 5 1 eo 1 GND RE 2 DATA 4 4 SE 2 3 DATA 3 P S If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX terminator is a male DMX cable connector with a 120 ohm resistor Between pin 2 and 3 The DMX terminator must be plugged into the DM
6. to fast 42 6s 120ms 150 179 Pulse close at variable speed from slow to fast 42 6s 120ms 180 204 192 Random Strobe Master and RGBW active 205 229 218 Random Strobe Full 230 255 240 Open DMX CHANNEL Parameter DIMMER NU Move DMX range range Mode Option Function Value NR A 0 255 Proportional dimmer _ INN Move DADO renge range Mode Option Function Value V rs 0 255 Proportionalcolour TESS Move Value UNI Ceres 0 255 Proportional colour 23 FOS 100 DYNAMIC DMX CHANNEL Parameter BLUE Ga Move DADA camge range Mode Option Function Value Se 0 255 Proportional colour DMX CHANNEL Tr Parameter WHITE NA Move DMX range range Mode Option Function Value aS DER 0 255 Proportional colour Parameter WHITE Pre programmed White at diff color temperature DMX range Mode Option Function Value o 055 No Function 56 105 80 Full Red Green Blue White at Full 106 155 130 White DTS IF CHANNEL 10 FUNCTIONS CUSTOM WHITE RECALL Dmx range value 0 79 156 205 180 Custom White Recall 206 255 225 White CTC Channel 7 CTC enabled l 256 color temp Correction Macros 2700K 8000K IF CHANNEL 10 FUNCTIONS CUSTOM WHITE CREATE Dmx range value 80 160 156 205 Custom White Create RGB levels selectable by DMX 206 255 White CTC Channel 7 CTC enabled 256 color temp Correction Macros 2700K 8000K _DMX CHA
7. FOS 100 DYNAMIC FC 4 The Lighting Gompany Made in Italy 2 FOS 100 DYNAMIC Le informazioni contenute in questo documento sono state attentamente redatte e controllate Tuttavia non e assunta alcuna responsabilita per eventuali inesattezze Tutti i diritti sono riservati e questo documento non puo essere copiato fotocopiato riprodotto per intero o in parte senza previo consenso scritto della D T S DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche funzionali o di design a ciascun proprio prodotto D T S non assume alcuna responsabilit sull uso o sull applicazione dei prodotti o dei circuiti descritti The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein Les informations contenues dans le present manuel ont t redigees et controlees avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d eventuelles inexactitudes Tous droits r serv s Ce document ne peut tre copi photocopi ou reproduit da
8. MX or Program variation Off 25 ms delay Fast response Range Off 20 IS 20 250 ms delay Slow response fi ENTER Up Down Default 4 ENTER COMPRESSION ene IH This menu allow to select between IA SEU PONSE ODIA aaa linear current output or guadratic current output for LEDs 20 250 ms Default Linear Smooth response to DMX variation SYNC E This menu allow to adjust the PWM cone Linear Linear frequency value Hz in order to Up Down ENTER Up Down current output ENTER reduce flickering in the process of your camera recordings Quadratic Linear light ENTER output BOOST DRIVING This menu allow to increase the LED s 1000 Hz current from 370 mA to 550 mA Up Down ENTER Up Down E ENTER 65k Da Boost mode activated RS ENTER Up Down ENTER a Boost mode deactivated lt With BOOST active the LED s current is set to 550 mA 30 more gain Default Activated gt RS IS MENU Up Down ENTER ES Up Down AUTOMATIC MODE Automatic demo game without DMX controller ChPr Chase with 16 steps previously created in REC MODE Speed and Wait time selectable by user CUPr RGBW values selectable by user Rainbow rAIn Rainbow colours effect Speed time selectable by user CU01 CU16 Color Macros as on DMX channel 8 Macro WHITE MACROS 16 macros for White colour from 2800 to 6500 K DIMMER Dimmer level selectable by user as on DMX channel 2 Dimmer Dimmer level is active for all the programs and macros SHUTTER Shutt
9. NNEL 8 Parameter CTC Color temperature correction Move ADO ass range Mode Option Function Value degrees IF CHANNEL 6 White WHITE CTC Dmx range value 206 255 0 255 256 color temp Correction Macros 0 2700K 128 5500K 255 8000 K IF CHANNEL 6 White NO FUNCTION Dmx range value 0 55 0255 No Function 24 FOS 100 DYNAMIC DMX CHANNEL 9 Parameter COLOUR MACROS IF ES IS ISIS ISIS Sto I PLEASE CHECK PAGE 11 Move DMX range range Mode Option Function Value degrees IA 1529 Yoo Marto 3044 Macro 2 48589 jo Maero3 __ O O 60 74 Mr O Bo Y Maeros 90104 Macro6 tosto o Y Mao 120134 yo o o o Macro 8 135 149 Macro 9 150 164 MaecrodO 165 179 Yo Marena 180194 Macro dt 195 209 Macrot3 S 210 2235 Macro vv 26239 Maro O OS 240255 Macro O DMX CHANNEL 9 Parameter COLOUR MACROS Move range Mode Option Function degrees o No Function O o Macrot Marea Yoo Mares o Yoo Mara o Macros O o Macro6 OOO Lp Maron Mares o RR o E o o E o NI o E O TNA IO DMX range Value EC asa zw Caras O 946 ama ss Cem Cas ose era INCITA 103 110 ams o 19 16 onma oo 38 12 25 FOS 100 DYNAMIC DMX CHANNEL 9 Parameter COLOUR MACROS IF E A ISIS ISIS CHES PLEASE CHECK PAGE 11 Move DMX range range M
10. R TEST MODE RGBW LEDs test with rainbow SE ss MENU Up Down ENTER SOFTWARE Unit software version and LED driver cards software version DMX PROTOCOL 60 CHANNELS MODE Default 1 RED1 2 GREEN1 3 BLUE1 4 WHITE1 5 RED2 6 GREEN2 BLUE2 8 WHITE2 57 RED15 58 GREENi5 59 BLUE15 Move range AA ERA DMX range Value 0 255 Move range A UE DMX range Value 0 255 FOS 100 DYNAMIC Proportional colour DMX CHANNEL Parameter BLUE1 Move range A a DMX range Value 0 255 Proportional colour 17 FOS 100 DYNAMIC cs TA DMX range Value 0255 Proportional colour DMX CHANNEL macanan NS Parameter RED15 DMX range Value DMX range Value DMX CHANNEL Parameter BLUE15 DMX range Value moon am DMX range Value 0255 Proportional colour 18 FOS 100 DYNAMIC DMX PROTOCOL 14 CHANNELS MODE SHUTTER DIMMER RED GREEN BLUE WHITE EFFECT 1 COLOUR 1 PARAM 1 10 LEVEL1 11 EFFECT 2 12 COLOUR 2 13 PARAM 2 14 LEVEL 2 OON A URWN b DMX CHANNEL 1 Parameter SHUTTER Move DADO ange range Mode Option Function Value Black out a iui Open 2029 24 po Black out 30 119 Strobe at variable speed from slow to fast 3 27s 30ms 120 149 Pulse open at variable speed from slow to fast 42 6s 120ms 150 179 Po Pulse close at variable speed from slow to fast 42 6s 120ms
11. X out panel connector of the last unit connected to the DMX line DMX MALE CABLE CONNECTOR GND DATA DATA 120 OHM PLACE A 120 OHM RESISTOR BETWEEN PIN 2 AND 3 OF AMALE DMX CONNECTOR AND PLUG IT INTO THE DMX OUT PANEL CONNECTOR OF THE LAST UNIT CONNECTED TO THE DMX LINE 10 FOS 100 DYNAMIC DMX ADDRESS FOS 100 DYNAMIC can be used in 4 different DMX modes 10 DMX channels 14 DMX channels 4 DMX channels or 60 DMX channels default If you want to use the FOS 100 DYNAMIC in 10 channels mode select the 10 CH mode from the MODE menu and set the following addresses on the mixer Projector 1 A001 Projector 2 A011 If you want to select the next projector just add 10 Projector 3 A021 uae A projector 6 A051 If you want to use the FOS 100 DYNAMIC in 14 channels mode select the 14 CH mode from the MODE menu and set the following addresses on the mixer Projector 1 A001 Projector 2 A015 If you want to select the next projector just add 14 Projector 3 A029 eae Pia projector 6 A071 If you want to use the FOS 100 DYNAMIC in 60 channels mode select the 60 CH mode from the MODE menu and set the following addresses on the mixer Projector 1 A001 Projector 2 A061 If you want to select the next projector just add 60 Projector 3 A121 enih A projector 6 A301 Selelcting the DMX address 1 Press the UP DOWN key until you reach the reguired DMX address The numbers on the display will start to flash
12. but the new DMX address hasn t yet been set 2 Press ENTER to confirm your selection The numbers on the display will stop flashing and the projector is now controlled by the new DMX address TIPS if you keep pushed the UP or DOWN keys the channels are calculated more guickly and you get a faster selection Li FOS 100 DYNAMIC DISPLAY FUNCTIONS oo a ae DFP Digita Function Panel DISPLAY FUNCTIONS The FOS 100 DYNAMIC display panel shows all the available functions Using these functions it is possible to change some of the parameters and add some functions Changing the D T S setting can vary the functions of the unit so that it does not respond to the DMX 512 signal used to control it Carefully follow the instructions below before carrying out any variations or selections NOTE the symbol IS shows which key has to be pushed to obtain the desired function Software version 1 08 DISPLAY STAND BY To turn off the display after 5 seconds or leave it always on Display always ON ENTER E a IS m IS m IS mg Floor IS 800 CS Up Down ENTER Up Down ENTER Up Down position ERES REVERSE DISPLAY Reverses display s reading depending on Suspension Is the mounting position on the ground or position RU suspended Up Down ESP CH1 SHUTTER CH2 DIMMER 10 CHANNELS Nt CH3 RED CH4 GREEN CH5 BLUE CH 6 AMBER CH7 WHITE IF IS IF IS MENU Up Down ENTER Up Down DMX MODE To select DMX mode 10 14 4
13. cene as last scene DMX channel 13 RECORDING channel Records the set scene with a variation between 0 to 255 the display flashes indicating that the scene has been recorded It is advised that you keep the REC channel set to 0 and to run through the 255 only once you have decided to save the scene If ChPr is not closed by indicating the last scene Edit channel between 235 255 in playback mode all 16 scenes will be played through even if not programmed Sue SL AU Sur E RJE p Down ENTER ENTER Up Down SLAVE MODE Slave mode for ChPr program All slave units will be synchronised with master unit running their own Chpr program ENTER 11 MENU Up Down Lee Ls ENTER Up Down EMERGENCY Emergency operating mode By setting Emergency mode it will be possible to select one of the 16 preprogrammed WHITE cues that will then ran if DMX SS ENTER Default OFF IS ES Down ai i ua ENTER Default White 1 signal is missing or not available Usefull for Emergency EXIT illumination on public areas Default 255 ES MENU Up Down ENTER DEFAULT To restore default settings ES 15 FOS 100 DYNAMIC a T1 T2 and T3 temperatures MENU Up Down ENTER ENTER Celsius TEMPERATURE T1 T2 and T3 temperatures lL bu visualisation EL a ENTER IS IS IS IS MENU Up Down ENTER Up Down LIFE TIME This menu show the total UNIT life time and the RGBW life time FE i MENU Up Down ENTE
14. ees 0255 EffectiParameter INN Move PINES ras range Mode Option Function Value DO degrees Value 000 047 023 NO EFFECT 048 063 056 Background 064 079 070 HystogramLeft 080 095 087 THystogramRight 096 111 104 Ss Hystogram Multicolor Left 12 17 120 Hystogram Multicolor Right 128 143 136 ContinousShiftRight 144 159 152 ContinousShiftLeft 160 175 168 Save Right 176 191 184 WaveLeftt o o 192 207 200 RandomStrobo _ 208 223 215 _ RandomStrobo Random Colour 232 v 224 239 232 Pulse 240 255 247 Random Pick DMX CHANNEL Parameter COLOUR 2 Move range Mode Option Function DMX range Value degrees 0255 po Colour Selection 21 FOS 100 DYNAMIC DMX CHANNEL Parameter PARAM 2 DMX range Mode Option Function Value 0255 Efect L Parameter Value 0255 __ Proportional Dimmer Effect 2 22 FOS 100 DYNAMIC DMX PROTOCOL 10 CHANNELS MODE SHUTTER DIMMER RED GREEN BLUE WHITE WHITE PRE PROGRAMMED CTC COLOURS MACRO O FUNCTIONS BF O ON OUR WN KH Parameter SHUTTER DMX range Mode Option Function Value a FS Black out 10 19 4 Open 2029 24 po Black out 30 119 Strobe at variable speed from slow to fast 3 27s 30ms 120 149 Pulse open at variable speed from slow
15. er level selectable by user as on DMX channel 1 Shutter Shutter level is active only for CU01 CU16 and Wh01 Wh16 macros ESC Exit from Automatic Mode Menu FOS 100 DYNAMIC iS ChP IF ENTER Up Down S ENTER IS SPEE ES Up Down OU 101 RE JE ENTER Up Down ENTER do ENTER Up Down ENTER R R 14 FOS 100 DYNAMIC Be EE Le ECE OHM REC MODE In DMX Recorder Mode it is possible to create and store the scenes of the ChPr by using an external DMX controller The unit must be setted to 10 channels MODE DMX Recorder Mode For the programming of ChPr by using a DMX controller besides the 10 channels necessary to control the unit a further 3 DMX channels are needed So that in RECORDER mode via DMX the unit will need 13 channels to be correctly programmed The three new DMX channels are DMX channel 11 SCENES channel From 0 10 no function r001 From 11 255 are displayed the programmable scenes max 16 scenes from M001 to M0016 DMX channel 12 EDIT channel From 0 19 no function From 20 234 the unit runs the configuration given by the received input DMX values With the channel SCENES it is possible to pass from one step to the next while with REC it is possible to record the selected scene From 235 255 the unit runs the configuration given by the received input DMX values closing the sequence as last scene With the channel REC it is possible to record the selected s
16. he unit until at least 5 minutes have elapsed since the unit was turned off Never install the unit in an enclosed area lacking sufficient air flow The ambient temperature should not exeed 40 C and should not be lower than 10 C UNIT DIMENSIONS vel m po Sn Ss Im if ma A nilis O IN dil O DAI ao Lo 4 0 9 fap o LJ LO L Packing Dimensions LxWxH 1060 x 160 x 200 mm Weight 7 5 Kg INPUT OUTPUT CONNECTIONS FOS 100 DYNAMIC IP20 FOS 100 DYNAMIC M12 LED output Female panel connector DMX IN OUT Panel Connectors MADE m may R Mains 90 260 V AC 50 60 Hz input Powercon Female panel connector M12 5 PINS LED input Male cable connector M12 5 PINS LED output Female panel connector XLR 5 pins Male Female uf DMX OUT o 4 CURRENT on mag 20 ag AM Ma ba 1004 Fibre MAINS OUT a an me L Mains 90 260 V AC 50 60 Hz output Powercon Female panel connector MAX load 230 VAC 20 FOS 100 DYNAMIC 100 V AC 10 FOS 100 DYNAMIC LEDS CONNECTOR PINOUT 1 DMX DATA 2 GROUND 3 DMX DATA 4 24V DC 5 HEARTH 7 FOS 100 DYNAMIC INPUT OUTPUT CONNECTIONS FOS 100 DYNAMIC IP65 Mains 90 260 V Ac Mains 90 260 V Ac 50 60 Hz input cable 50 60 Hz output ILME 5 pins Female panel connector DMX IN MAX load naka pins Female 230 V Ac 20 FOS 100 DYNAMIC anel Connectors 100 V Ac 10 FOS
17. hecked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein MADE IN ITALY The Lighting Gompany ISO 9001 2008 D T S guality system is certified to the ISO 9001 2008 standard D I S products are designed and manufactured at the D T S plants in italy 05171128 D T S Illuminazione s r l Via Fagnano Selve 10 12 14 47843 Misano Adriatico RN Italy Tel 39 0541 611131 Fax 39 0541 611111 info dts lighting it www dts lighting it
18. ns sa totalit ou partiellement sans le consentement pr alable de D T S D T S se r serve le droit d apporter toutes modifications et am liorations esthetiques fonctionnelles ou de design sans pr avis a chacun de ses produits D T S d cline toute responsabilit sur l utilisation ou sur l application des produits ou des circuits d crits Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas Con todo no se asume ninguna responsabilidad por eventuales inexactitudes Todos los derechos han sido reservados y este documento no puede ser copiado fotocopiado o reproducido total o parcialmente sin previa autorizacionescrita de D T S D T S se reserva el derecho a aportar sin previo aviso cambios y modificaciones de caracter est tico funcional o de diseno a cada producto suyo D T S no se asume responsabilidad de ningun tipo sobre la utilizacion o sobre la aplicaci n de los productos o de los circuitos descritos 3 FOS 100 DYNAMIC DESCRIPTION FOS 100 DYNAMIC FC is a new compact LED bar with power supply on board designed for colouring large surfaces with a uniform projection either indoor and outdoor FOS 100 DYNAMIC FC can be used for many applications such as professional for an ample range of special events theatre and television for uniform background colours and cycloramas architectural for lighting building facades public and commercial spaces monuments etc All m
19. ode Option Function Value O KAANANE grees 143 150 Rainbow Speed 1 Sec His tesi 6 e 159 166 RaimbowSpeed3 10 Sec 167 174 TO Rambow Speed 4 20 Sec 175182 J RainbowSpeed5 0Sec 183 190 TO Rainbow Speed 6 60 Sec 191198 __ Rainbow Speed 7 120 Sec 199 206 __ Rainbow Speed 8 180 Sec 207 214 __ Random Speed 1 0 5 sec 215 222 Random Speed 2 1 Sec 223230 Random Speed 3 2 Sec 231238 __ Random Speed 4 5 See 239246 Random Speed 5 10 Sec 247255 ll Random Speed 6 30 Sec Parameter FUNCTIONS Recall Create and Store the Custom white DMX range Mode Option Function Value 079 Custom White Recall Enable CH 7 for Custom white Recall 80 160 PY Custom White Create Enable CH 7 for Custom white Creation 161 255 IN Custom White Store Store the Custom White created 26 FOS 100 DYNAMIC DMX PROTOCOL 4 CHANNELS MODE 1 RED 2 GREEN 3 BLUE 4 WHITE jann AAA DMX range Mode Option Function Value 0255 Prroportional colour v DMX range Mode Option Function Value 0255 Proportional colour DMX range Mode Option Function Value 0255 Proportional colour Value 0255 Proportional colour 2 NOTE The information contained in this publication has been carefully prepared and c
20. odels are made on aluminium offering high resistance to mechanical stress Protection rating can be IP65 outdoor or IP20 indoor FOS 100 DYNAMIC FC light source is composed of 15 x FULL RGBW LEDs which can independently generate 16 million colours colour temperature can be controlled linearly from 2 00K to 8000K The 15 FULL RGBW LEDs can generate the same colour at the same time so that the illuminated object is not only uniformly lit but also projects no false shadows and different colours at the same time indipended control for each FULL RGBW LED in 60 channels mode in order to create an infinity combination of colours Three dedicated lenses sets Spot Medium flood and Wide flood are available for each model offering different light beam projection angles Set up and connection of the units is fast and easy thanks to the dedicated on board power supply FOS 100 DYNAMIC FC can be controlled via any DMX lighting console D T S Product codes O3 DYN007S F10 FOS 100 SOLO DYNAMIC FC IP65 Spot lenses Black finish 03 DYN007S F25 FOS 100 SOLO DYNAMIC FC IP65 Medium flood lenses Black finish 03 DYN007S F40 FOS 100 SOLO DYNAMIC FC IP65 Wide flood lenses Black finish 03 DYNO08S F10 FOS 100 SOLO DYNAMIC FC IP20 Spot lenses Black finish 03 DYN008S F25 FOS 100 SOLO DYNAMIC FC IP20 Medium flood lenses Black finish 03 DYN008S F40 FOS 100 SOLO DYNAMIC FC IP20 Wide flood lenses Black finish All models are also available
Download Pdf Manuals
Related Search
Related Contents
Delta Faucet Linden 4353-DST User's Manual Atlantic Solo Manual ET-1400 - Ferramentas Gerais Wonderware (TM) FactorySuite (TM) Recipe Manager User Guide Philips Small vacuum cleaner nozzle FC6022 Operating Manual User manual Smithco Paint Sprayer 3007 User's Manual HDC-AE 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file