BPS100 user manual.indd

image

Contents

1. Contact B amp W TEK and obtain authorization to return the item s in the form of an RMA Return material authorization number For customers in the USA and countries where distributorship and or representation is not available all claims should be addressed to Customer Service B amp W TEK INC 19 Shea Way Newark DE 19713 Be prepared to furnish Product Model number and serial number Date of shipment purchase Brief description of the problems encountered Name of contact person and phone number s at your organization for further communication aoo Obtain B amp W TEK s instructions for transportation and packaging and ship the product freight and insur ance prepaid with the proper documentation containing the RMA number and the information specified above B amp W TEK will advise the purchaser of its determination of warranty at the earliest possible time Providing complete information as requested will expedite the procedure 19 Shea Way Newark DE 19713 USA Tel 302 368 7824 Fax 302 368 7830 E mail info bwtek com
2. B PS1 00 Rev 032305 USER MANUAL BPS100 Photo Feedback Controlled High Stability Tungsten Light Source 19 Shea Way Newark DE 19713 USA Tel 302 368 7824 Fax 302 368 7830 E mail info bwtek com BPS100 Tungsten Source Mounting post sold separately a BPS100 accessories Power supply connection 2 B PS1 00 Rev 032305 Introduction The BPS100 series is a line of low cost and high performance con stant photo intensity tungsten light source products By use of photo intensity feedback control the BPS100 demonstrates up to one order of magnitude improvement in output power stability compared with conventional source when operated under constant current mode The BPS100 is ideal for spectroscopic applications in visible and near IR Specifications Power input Operating temperature Light bulb Rated power Lifetime Filter holder Light coupling Power supply input Power supply output Remote port Control functions Modulation input Remote on off control Current monitoring Installation Electrical 5VDC lt 1 0A 0 to 40 C Gas filled tungsten 4 5 W gt 5 000 hours at rated conditions For filters 0 5 in diameter at lt 0 25 thickness SMA 905 100 240 V AC for factory default power supply 5V DC 1 6 or 2 0 A 4 pin RJ11 connector Modulation and on off controls Operating current monitoring Analog DC input 0 5 V better than 1 5 Hz corr
3. S100 Make sure to tighten the SMA 905 mounting cap Filter holder aseembly 3 19 Shea Way Newark DE 19713 USA Tel 302 368 7824 Fax 302 368 7830 E mail info bwtek com B PS1 00 Rev 032305 2 In case a filter needs to be loaded shut off the light source power and then remove the two mounting screws on the filter holder lid Load filter s and secure the filter s by using the set screw located on the bottom of the filter holder 3 Reattach the loaded filter holder and fasten it with the two mounting screws NOTE The filter holder needs to be installed into the Filter holder orientation Short BPS100 housing in the orientation that the filter is close to the distance side should face the front panel side Installation of the filter so that the filter part is front panel when install close to the light bulb may result in inappropriate operations of the source 4 19 Shea Way Newark DE 19713 USA Tel 302 368 7824 Fax 302 368 7830 E mail info bwtek com B PS1 00 Rev 032305 WARRANTY TERMS AND CONDITIONS B amp W TEK s end user products OEM modules and components are warranted to be free from defects in materials and workmanship for a period of 12 months 6 months and 90 days respectively from the date of initial shipment This warranty does not extend to incidental or consequential damages and to damage caused by neg ligent or improper handling in use storage nor for products for which the origina
4. esponding to minimum and maximum output power setting TTL logic input 0 or 5 V DC up to approximately 15 Hz DC output 0 1 V corresponding to approximately 0 1 A operating current Follow the procedures as described below for the electrical installations 1 Plug in the supplied power supply connector into the matching receptacle on the rear panel 2 Plug the power supply AC into an outlet 100 240 V AC 19 Shea Way Newark DE 19713 USA Tel 302 368 7824 Fax 302 368 7830 E mail info bwtek com B PS1 00 Rev 032305 3 The supplied RJ11 connector may be used for remote control purpose The following table describes the pinouts and color code of the control signals NOTE The BPS100 operates via the on off power switch without the need for connecting the RJ1 remote control connector Use the RJ11 connector only for remote needs to be performed Table Remote control port signals Remote port RJ11 connector 4 Turn on the power switch located on the rear panel The light source will start to emit after a short delay and slow ramp ing Optical IMPORTANT NOTICE There is a filter holder incorporated into the BPS100 light source for possible use with optical filters Always turn off the light source power before loading filters or removing the filter holder Fail ure to do so may result in damage to the light bulb r 1 Connect an optical fiber jump cable to the emission port of the BP
5. l identification markings or labels have been removed defaced or altered Special contracts or contracts for nonstandard products may have modified terms of warranty and in such cases the terms as stated in the individual contract must be signed by the duly authorized officer of B amp W TEK and will supersede the standard terms B amp W TEK will make final determination as to cause or existence of defect and at its option repair or replace the products which prove to be defective during the warranty period Products replaced under warranty will be warranted only for the balance of the warranty period from the original supplied equipment This warranty extends only to the original purchaser of the equipment from B amp W TEK The purchaser must notify B amp W TEK within 15 days of first noticing the defect and promptly return the defective product upon receipt of RMA number s before expiration of the warranty period Products believed by purchaser to be defective shall be returned to B amp W TEK transportation and insur ance prepaid by purchaser Repaired or replaced products will be returned to purchaser by B amp W TEK FOB city destination within the Continental United States Transportation beyond these limits will be charged to purchaser Warranty Return Procedures Review terms of purchase and date of shipment to determine validity of warranty claim Warranty claim should only be made for products within terms of warranty policy