1. 1 180 FOG MACHINE USER MANUAL 5 UL 5 998 US CERTIFIED To CSA 22 4090823 NO 104 2 B 5 C l 1880 EXTERNAL VIEW 1 Nozzle 2 Body 5 Yoke 7 Control socket 8 Fuse holdes 9 Power cord 5 4 Tightening screw 10 Foot 5 Washer 11 Remote control Tank amp tank 3 ghee 2 A ey 7 a we es 2 2 i a w i 3 5 EN ii re Tighten ne screw Vasher OPT Tee Lighlizg And Effects Lid POs MACHINE 7 FOS Thank you for choosing the 1 180 You now own a rugged and powerful state of the art machine Prior to use we suggest that you carefully read all of the instructions By following the suggestions found this user manual you can look forward to exceptional performance from your 1 180 fog machine for years to come Please follow these operation safety and maintenance instructions to ensure a long and safe life for your fog machine SPECIFICATIONS Heater 700W a aaa a a asss Weight 3 6 kg CAUTIONS Ay Pay attention to all warning labels and instructions printed on the exterior of your 1 180 fog machine Danger of electri
2. c shock Keep this device dry For inside use only Not designed for outside use For the 110V models use 3 prong grounded electrical outlet only Prior to use take care to determine that the unit is installed at the rated voltage Always unplug your 1 180 fog machine before filling its tank Keep fog machine upright Turn off or unplug when not in use This machine is not water or splash proof If moisture water or fog liquid gets inside the housing immediately unplug the unit and contact a service technician or your dealer before using it again user serviceable parts inside Refer to your dealer or other qualified service personnel Danger of burns For adult use only Fog machine must be installed out of the reach of children Never leave the unit running unattended Keep nozzle at least 50 cm 20 in away from contact with anything while in operation The fog vapour at point of release is under pressure and is extremely Never aim the output nozzle directly at people Fog machine output is very hot Avoid coming within 50 cm of the output nozzle during operation Locate the fog machine in a well ventilated area Never cover the unit s vents In order to guarantee adequate ventilation allow a free air space of at least 20 cm around the sides and top of the unit Never aim the output nozzle at open flames The output nozzle becomes very hot during operation 300 degrees K
3. eep flammable materials at least 50 cm away from the nozzle Always allow your I 180 fog machine to cool down before attempting to clean or service it Danger of explosion Never add flammable liquids of kind oil gas perfume to the fog liquid Use only the high quality water based fog liquid that your dealer recommends Other fog liquids may cause poor effect fog clogging and spitting of unevaporated liquid Always make sure there is sufficient liquid in the fog liquid tank Operating this unit without liquid can cause damage to the pump and the heater If your 1 180 fog machine fails to work properly discontinue use immediately Drain all fog liquid from the tank pack the unit securely preferably in the original packing materials and return it to your dealer for inspection Always drain tank before shipping or transporting this unit If fog liquid comes in contact with skin or eyes rinse thoroughly with water Never drink fog liquid If ingest accidently and feel not well call a doctor immediately Unpacking amp Inspection Open the shipping carton and check that all equipment necessary to operate the system has arrived intact In addition to the 1 180 fog machine you should receive the following items 802 wired remote Hanging bracket 3 800 1 quart liquid tank Before beginning initial setup of your 1 180 fog machine make sure that there is no evident damage cau
4. ogging Running a fog machine without fluid can permanently damage the unit If you experience low output pump noise or no output at all unplug immediately Check fluid level the external fuse remote connection and power from the wall If all of the above appears to be O K plug the unit again If fog does not come out after pressing the remote button for 30 seconds check the tube attached to the tank to make sure there is fluid going through inside If you are unable to determine the cause of the problem do not simply continue pressing the remote button as this may damage the machine Return the machine to your dealer for inspection Performance Notes All fog machines develop condensation around the output nozzle Because this may result some moisture accumulation on the surface below the output nozzle consider this condensation when installing your machine Fog machines may sputter small amounts of fog occasionally during operation and for a minute or so after being turned off 1180 fog machine has a heating cycle after bursts of fog so the machine stops fogging for a short period in order to heat up During this time no fog can be produced e Only use liquids with certified suitability Save these instructions
5. ot to point the nozzle direction that will aim directly at a person Whatever installation method you choose do not allow the unit to have more than a 15 degree angle of inclination Remote Control Operation 802 41 meter wire remote controller for 1 180 fog machine 5 Option The wireless remote controller for 1 180 fog machine Remote operation of on off function is possible up to a distance of 50 meters Do not allow the fog liquid to become contaminated Always place back both the caps the fog liquid tank and the fog machine liquid tank immediately after filling After every 40 hours of continuous operation it is recommended to run distilled water through the system to prevent the accumulation of particulate matter in the heating element When cleaning use only a clean lint free cloth An effective cleaning regimen is as follows 1 While unit is unplugged cool unscrew nozzle at very front of unit and clean out debris with vinegar and a pipe cleaner making sure that the hole is free of clogs 2 Empty all fog fluid from machine Add cleaning solution to tank Plug unit in and begin warm up 3 Run unit in a well ventilated area until tank is empty 4 Replace nozzle and refill with liquid Cleaning your fog machine regularly will help reduce costly parts replacement and repair charges Always monitor tank fluid level as you are f
6. sed by transportation Inthe event that the unit s housing or cable is damaged do not plug it and do not attempt to use before contacting your dealer for assistance Remove all packing materials from the fog machine Check that all foam and plastic padding is removed especially in the nozzle area Fill with high quality water based fog fluid Any other types of fluid can damage the unit When filled place cap back on the liquid tank Firmly connect the remote control to the proper input on the rear of the machine Operation Plug power cord into a grounded electrical outlet Then turn on the power switch on the rear of the unit The machine starts to warm up and the red lamp on the remote control will be on When warm up is complete the red lamp is off To emit fog press the button on the remote and hold for the desired length of time The remote unit s lamp will cycle on and off as the machine re heats to the proper operating temperature For further information on operating your 1 180 fog machine see the section titled Remote Control Operation Installation The 1 180 fog machine includes a mounting bracket designed for overhead installation This bracket allows the unit to be hung from lighting equipment trussing or other suitable supports The unit can also be operated at floor level or sitting on any regular surface as well lf the unit is to be mounted with the hanging bracket it is important n