Home

USER'S MANUAL TP1043 series

image

Contents

1. TP1043 mect srl EN 55011 radiated 40 dB uV m 130 MHZ 230 10m 47 dB uV m 1230 MHz 1 Emissions according to EN 61000 6 3 2001 values IQPI Range EN 55022 AC supply 66 56dB_ 150kHz 500 ducted conducted 56 dB uV 500 kHz 5 60 dB uV 5 MHZ 390 EN 55022 DC supply data 40 30dB 150kHz 500 conducted 30 dB uA 500kHz 30 EN 55022 radiated 30 dB uV m 30 MHz 230 37 dB uV m 1230 MHz 1 Attention Install the device in a panel with no more than 55 C 3 2 Panel mount 3 2 1 Distance System must be installed with a space for heat dissipation and cabling Avoid cabling superimposing to avoid EMC problems Figure 6A Horizontal mounting ME7029_04 06 15 7 TP1043 mect srl Figure 6B Vertical mounting 4 TP1043 wiring 4 1 Connections In the following figure see the wiring diagram ir moro Lui Figure 7 ME7029_04 06 15 8 TP1043 mect srl Table 3 Power Supply 24Vdc Vac 10 20 250mA 24Vdc Micro USB 2 0 Ethernet Bit rate 100Mbit sec Serial ouputs RS485 Modbus half duplex hardware configuration or CANopen 4 2 Power supply 4 2 1 Isolation Device has no galvanic isolation between input output and power supply 4 2 2 System power supply TP1043 has a 24Vdc Vac 10 20 according to the scheme in the figure System is protected against reverse power supply 4 2 3 Fuse
2. System has no internal fuse so is suggested the use of an external 500mA fuse for the panel power supply _ o ETT Tr U D MICRO Q usb 24 Vdc Vac Figure 8 Attention A wrong value for the power supply can cause a damage to the device ME7029 04 06 15 9 TP1043 mect srl 4 3 ModBus wiring ModBus on TP1043 is a 2 wire RS485 serial line on the terminal board on pins Table 4 Pin Signal Description AAA De Linea Example of a wiring of a system composed by e TPLCOOS e MPNCO20 e MPNCO30 e TP1043 T ModBus 2 wires 24VDC di LL 24Vdc Vac A T GNDiso AW rs de Figure 9 ME7029_04 06 15 10 TP1043 mect srl 4 4 CANOpen wiring The CANopen interface on TP1043 must be connected to the terminal block on the pins shown in the table Table 5 Pin Signal Description 3 GNDiso Example of a wiring of a system composed by e MPNCOI10 e MPNCO30 e TP1043 CANOpen 24Vdc F DI 24Vdc Vac la i GND iso Na s pe Lf E r te E MPNCOSO MPNCO10 Figure 10 ME7029_04 06 15 11 TP1043 mect srl 5 Peripherals 5 1 USB TP1043 has a Micro USB 2 0 host for e software update e data storage datalogger e connect USB peripherals as printers mouse etc Specific connection of external peripherals are implemented on request 5 2 Ethernet TP1043 has a 10 100Mbit s ethernet port with auto co
3. the TP1043 dimensions Rear view 3 1 Mechanical dimensions Side view 139 0 Figure 3 Figure 4 Side view 125 0 Figure 5 06 15 ME7029_04 TP1043 mect srl Technical specification Table 2 p SE S o IO SE ls p o e T ABS Polycarbonate Dimensions W x 27 7 mm x 159 mm x 83 mm Mounting plate nstallation Environmental conditions Operative temperature DEC ad E Storage Temperature 20 C 85 C Relative Humidit 5 a 95 no condensation Electric isolation Air clearance 127mm x 68mm Panel installation According to IEC 60664 1 Pollution According to IEC 61131 2 Protection Rear protection Front protection MC IP 20 IP65 E EMC according to EN 61000 6 2 2001 Values Criterion EN 61000 4 2 ESD 4 kV 8 kV contact air EN 61000 4 3 10 V m 80 MHz 1 GHz electromagnetic fields EN 61000 4 4 burst 1 kV 2 kV data suppl EN 61000 4 5 surge Test specification N Oo E N Uo Data DC 0 5 kV line line 1 supply 0 5 kV line earth 1 AC 1 KV line line 2 supply 2kV line earth 3 10 V m 80 AM 0 15 80 RF disturbances MHz Emissions according to EN 61000 6 4 2001 Test specification Distance values IQPI Range EN 55011 AC supply 79 dB uV 150 kHz 500 conducted 73 dB uV 1500 kHz 30 ME7029_04 06 15 6 BL N 9 E
4. USER S MANUAL TP1043 series McC T Via Enrico Fermi 57 59 10091 ALPIGNANO TO Telefono 39 0 11 9664616 Fax 39 0 11 9664610 E mail srimect mect it C F e P I 04056380019 ME7029_04 06 15 TP1043 mect srl INDEX er Modulo rain l e Sciliar 1 O Soli ei A i l lo onere 2 lb Sla 2 EN REFERENCE MANUAL aa a a a boat ate leas 2 Ze SY SUCUECES CH PHON rollin 2 Zlo SPec 0 6 2 1006 0 nadaa 4 Se Hardware TNS Ca WA Oise obelisco 5 del Mechanical CUTAN SUVS spa ad a II a 5 32 PE ENO Cs AS EA a E ceed bite O a RD abl Rice da 7 sl DR TOS 7 L IM 8 As COMMECHONS silla 8 40 POW Cl SUPPLY ns ri 9 o piloni esi ia 9 ADD System POWEL SUPPI senile 9 bi PISO et cia on III A 9 45 MODUS WO A an a Ra a otha a 10 dik CORNO OS leali 11 A A Nc na IO 12 Sila Sberl A i io ia 12 Doe PPP A 12 Os A iii lo E 12 AS AA a A 12 i a ai 12 ME7029_04 06 15 TP1043 mect srl 1 Introduction To grant a fast manual setup of the device please follow carefully the information in this 1 1 Staff skill Products described in this manual are devoted to PLC programmers or automation experts only MECT S r l declines any responsibility about malfunctioning or damage caused by incorrect use of MECT devices due to noncompliance to this manual information MECT S r l has an help desk 1 2 Simbols AMP e ee ME7029_04 06 15 Danger Follow this advice to avoid people
5. idth and 480 x 272 pixel resolution with 262 000 colors TP1043 allows the supervision of networked devices Modbus RTU and Modbus TCP The networks are managed simultaneously by TP1043 and data from a network can be sent on another thus creating a bridge between the two networks On TP1043 is present Micro USB host port that allows with an adapter the use of an USB pen drive for software updates and data log On TP1043 are up to 1 Kbyte of retentive variables stored on flash ME7029_04 06 15 2 TP1043 mect srl The device is also able to manage an up to 8GB wide micro SD card The SD card is factory mounted on request A real time clock buffered RAM maintains the date and time up to four months with the device turned off TP1043 is equipped with a micro PLC to make a small automation of the process The device can be applied in horizontal or in vertical design with the option V see following pictures Figure 1 Front view TP1007 horizontal version a 4 a e Figure 2 Front view TP1007 vertical version ME7029 04 06 15 3 TP1043 mect srl 2 1 Specification TP1043 is based on a multiprocessor system PLC and HMI are based on a 454MHz ARMO Table 1 PLC Processor RAM Non volatile variables Real Time Clock Screen i mH S ps EEE a IO la gt o o EIS YN VN ia Ia as Olga e w ME7029_04 06 15 4 mect srl TP1043 3 Hardware Installation In the following figures see
6. injury Warning Follow this advice to protect the device Caution Follow this advice to have a more effective performance ESD Electrostatic discharge Danger possibly damage due to Electrostatic discharge Note Step to follow for a correct installation Additional information TP1043 mect srl 1 3 Terms PLC TP1043 Terminals TPLC005 MPNC010 MPNC020 MPNCO30 System PLC TP1043 with terminals 1 4 Security Attention Switch off devices before connecting them ESD Electrostatic discharge A Modules have electronic components that can be damaged by electrostatic discharge Be sure to be connected to ground when handle the devices The instrument has no power switch and no internal fuse but it powers on immediately after connecting a correct power supply input check the power supply value on the instrument label Keep the power supply line as short as possible and keep 1t separate from other power lines For security reasons it is necessary to have a 2 section power switch with a fuse near the instrument and easily replaceable Avoid the presence of other power actuators in the same control panel high humidity excessive heat and corrosive gas Instruments must have a power supply from security transformers or SELV transformers 1 5 REFERENCE MANUAL ME7028 Mect configurator ME7041 Quick Start 2 System description TP1043 is a device composed by a PLC and a HMI with touch screen monitor 4 3 w
7. nfiguration moreover the connection cable between TP1043 and a personal computer can be either straight either cross 6 HMI To set the TP1043 is necessary to develop a software in QT Creator based on QT libraries custom tailored on MECT operator panel A specific tutorial is furnished with the device The QT Creator suite software is available in Windows environment 6 1 System variables The system can use 5472 interchange variables between HMI and automation at maximum which include internal variables interchange variables on Modbus network retentive variables The variables are defined by a software Mect Suite 7 How to order O A TP1043 01 B re 24 v A Interface B orientation C Options A R5485 Ethernet port Rj 45 Micro USB port Blank Horizontal Upon customer s request B CANopen Ethernet port Rj 45 Micro USB port V Vertical ME7029 04 06 15 12