Home

User guide

image

Contents

1. Rev 05 2011 C LEDs LEDs Rev 05 2011 C To indicate the state of the headend system and the individual units four LEDs are placed at the top of the output section having separate functions 00e60060600000009 0000000000000990 0000000000000000 00068600088 800660 COSSSSHOCCOSEHOCESO ooo eeeeeesee0008e800000 System status Unit link 2 Unit link 1 Tuner status The colours of the LEDs can be green green flashing or red The message delivered by the colour depends on the function of the individual LEDs System status Tuner status e Unit link 1 e J e Unit link 2 Green Power is on and the headend system is up and running Green flashing The headend system is booting Red An error has been detected in the headend sys tem and it must be investigated Green The tuners are locked Red One or more tuners are not locked Green The subunit is connected to the main unit Red There is a problem with the connection to the subunit No colour No subunit is connected to the main unit Green The subunit is connected to the main unit Red There is a problem with the connection to the subunit No colour No subunit is connected to the main unit Configuration Gi Configuration of system Rev 05 2011 C In order to set up and configure the modules within the headend system you ha
2. To take a module out of a slot in the output section tip the lock mechanism and then pull the module out Each output module has a LED on the front to signal whether the module functions according to its purpose Green flashing The module has not been configured yet Green No errors and everything is valid Red Error No colour Power has not been switched on LED When you update the software of a module the status LED provides you with information about the updating process Orange Boot loader state Temporary off Initiation of the software update Temporary green Every time the modules receives a valid data package Repeated until the update is completed without errors Red Software update failed A label is provided on the output module where you can write the informa tion regarding the configuration of the module The module type and code number are printed on the label Label A label with the bar code serial number and address printed on it is placed elsewhere on the module Output CAM Smart card You can insert 2 Conditional Access modules CA into each of those output modules that have CI slots Each CA module is able to unscramble at least one service Which services depend on the service provider of the CA mod ule and smart card CA module Smart card CA modules and smart cards inserted in the output modules Small Form Before you can connect the main unit with any subu
3. Look in CJ Triax 1 Navigate to the desired le folder My Recent Documents Lae 2 Select the file Ld My Documents gs 3 Click to open the file My Computer ng TAA Mo Nera File name TDX 5W 1 8 1 15262 ck Ba aos CA When you have clicked the Open button you return to the Firmware window In the Firmware window the new update file is placed at the bottom of the list of updates Click the file name to select the file and then click the Set active button to transfer the update to the TDX system Change firmware dialog 1 8 1 15256 1 8 1 15258 1 8 1 15259 1 Click the file name 1 8 1 15261 1 8 1 15262 2 Click the Set active button Clicking the Set active button displays the Firmware update window In this window you select whether you want to update all firmware i e modules system controller and user interface or only firmware that is in need of an update Triax recommend that you use the Replace all option when you want to up date your firmware You should only use Update old packages if your TDX headend system con sists mainly of new modules and a few older modules that might benefit from an update Rev 05 2011 C Updating firmware Firmware update status window Select update type for selected firmware 1 Click to update all firmware or click to update only firmware that needs updating 2 Replace all Update old packages Errors detected
4. User guide TDX Headend Unit 492090 t n il aaa Ah c RE i A a D A e i Y o N A a da ao Na By 4 LI a TRIAX your ultimate connection Contents G6CLLL GG Contents Iintroductioni mmiiiiiic 4 Box content 5 Unit xXteriof iui RR 5 Unit OOM vices cl 6 MOUNtIin g siccriiiiii IRR 8 Earthiig cc 9 INPUT modules 9 QUIDULMOUUIES ici 12 Cialde 14 Small Form factar Plugable SFP line 14 Connecting UNMS 15 RE RR AA AA AA AA AA 17 Power and RF Output GABI 18 LED 19 Configuration Of SYStemM iiiii 20 LOG INR 21 SysteM WINDOW la 22 System INO MALINANG 23 Comm McatioN ICOM sesca r iae ali io 24 Administration WINDOW AABANGAN 24 Lanalagg SETTINGS ina 25 Country SettiNgS naaa AA AA AA AA 26 Time ZONe SEO 27 Password SettiNgS AA AA 29 Licence handling AGA KAKAIBA AA AA 30 E EEA 31 Save Settings cilea 34 Create a new system configuration ssssssssssssnnnnnnnnnnnnnnnnnnnnnnnnnnn NAA 35 Save COMPQUPAUION csrl 36 Change system configuration nananana aak En Rap Ep ASEN Anua RaRa NaRa aNas 36 IPIVWINdOW sie 37 IPI configuration WING nre 38 SAS 41 Delete IP Up esiisa AA AA NAAN 42 Log Gia BIGAA TRE 43 Update firmware ANG BANANA BEN 46 REDOOt SVSteni iisil RR RR 51 Load to TDX AABANGAN 52 Load from TOXINS 53 Configuration of MOQUICS aaa ANA NAAANINAG NING 54 VOLUF NOTES aasaran aanp i Sianas eaei R aibida k sNa Enuiant isins 55
5. In the input section covers are used to protect all module slots For EMC reasons only remove covers from the module slots that you want to insert modules into Extractor fans have been placed in both the input section and the output section of the unit to prevent the unit from overheating In the output section you can slide the cover with the extractor fans from one side of the output section to the other when you want to install or replace output modules Cover plate has been removed Cover with extractor fans has been slid to the left Rev 05 2011 C 6 TDX Unit Below you can see an empty headend unit without the front and top 8 slots for input modules Earth terminal 8 slots for input Extractor fans modules Power supply Empty slot i with cover unit Power socket opooo 5 0000 3 slots for gt coahSo0g0 094939830 ka lt 3 slots for output osopsseds Haakaaaaa o output modules J E E E rs modules gt ma lo 9P300 ho B030 Nea NG RF output Configuration Unit link 1 amp 2 N Unit ID switch SD card slot port behind Test point 20dB Aux 1 amp 2 Extractor fan front cover RF output Dist
6. Rev 05 2011 C Safety Precautions Safety precautions Environment Power supply Earth Ventilation Disposal Rev 05 2011 C Operating temperature from 10 C to 50 C Storage temperature from 20 C to 70 C Max operating humidity 80 RH Max storage humidity 90 RH The input voltage must be 190 264 VAC 45 65 Hz 280 W Max Use only power connections installed by professionals Every unit in your headend system must be earthed by connecting it to the ground with a wire according to the electrical regulations of your country The way you position the headend units must leave a minimum of 10 cm on each side of the units for ventilation If you position the headend units side by side the distance between the units must be at least 20 cm 10cm 20cm Within in the European Union this label indicates that the product cannot be disposed of with the general household waste Neither the headend nor the input and output modules can be dis posed of with the general household waste For proper treatment and recycling of old products please take them to designated collection points in accordance with your na tional legislation Introduction _ Go ees GG Introduction Rev 05 2011 C With the TDX headend system Triax introduces the TDX pool which provides you with the full freedom of assigning services from any input to any set of output modules All
7. 20C72CD860087F99 1 Enter activation key 2 Click the Activate button gt IP settings gt System maintenance Enter the activation key in the Activation key field then click the Activate but ton to access the licence you have bought Settings IP settings Rev 05 2011 C Note Settings for TDX Service Tool Language settings Country settings Time zone settings Password settings lt vw v v v License handling View licenses and enter activation keys Serial number 0492000012011020240 TDX unique ID 3187912C102F Activation key IP service Quantity 12 gt IP settings gt System maintenance Information about the number of licences you have bought When you have clicked the Activate button to access your licence your TDX unique ID is changed and the activation key is deleted If you want to buy more licences you will have to contact Triax with the new TDX unique ID to Triax to get a new activation key to ac cess an additional licence When you have accessed your licence you use e g the IPTV tab to select the services you want to output in connection with the licence Settings for current TDX Service Tool Language settings Country settings gt gt gt Time zone settings gt Password settings gt Licence handling v IP settings Configuration Port Unit link 1 Unit link 2 Change IP subnet and default gateway address IP Addr
8. INFO systemcontroller src application frontend manager src CLTdxFrontendManagerTask DVB T frontend in slot 1 added INFO systemcontroller src application frontend manager src CLTdxFrontendManagerTask Frontend in slot 1 Bootloader SW Ver 1 1 0 14460 FS INFO systemcontroller src application frontend_manager src CLTdxFrontendManagerTask Frontend in slot 0 SIN Y Z ce ceE deed INFO systemncontroller src application frantend_manager src CLTdxFrontendManagerTask Frontend in slot 1 S N YgZ ce dYce d dQ INFO systemcontroller sro application frontend_manager sre CLTdxFrontendManagerTask Frontend in slot 0 Application SW Ver 1 8 1 15262 INFO systemcontroller src application frontend_manager src CLTdxFrontendManagerTask Frontend in slot 1 Application SW Ver 1 8 1 15262 INFO systemcontroller src application frontend manager src CLTdxFrontendManagerTask Frontend in slot O changed state to not locked INFO systemcontroller src application frontend_manager sre CLTdxFrontendManagerTask Frontend in slot 1 changed state to not locked INFO systemcontroller src application system manager src CLSystemErrorHandler System is in state ERROR INFO systemcontroller sre application tdx_unit_initiator src CLTdxUnitlnitiator System controller running FAILSAFE software version 1 8 0 14157 S N 04920000 INFO systemcontroller src application tdx_unit_initiator src CLTdxUnithnitiator Ip address 255 255 255 255 INFO
9. Settings for current TDX Service Tool v Language settings Change current language for TDX Service Tool Current language Click the arrow Engish to open the Danish 3 Spanish drop down list Italian Norwegian Swedish Finnish German Portuguese Country settings French Polish Time zone settings Password settings Licence handling IP settings System maintenance Select the language you want to use in the TDX Service Tool The language you selected is now displayed in the Current language field Rev 05 2011 C Settings _ Country settings To enter the Country settings area click the arrow bracket to the left of Country settings Settings for current TDX Service Tool v Language settings Change current language for TDX Service Tool Current language English v Click the arrow bracket to open the country area ountry settings Time zone settings Password settings Licence handling IP settings System maintenance Now you can see the fields of the Country settings area Settings for TDX Service Tool gt Language settings v Country settings Change location for the TDX installation Current location Denmark v Time zone settings Password settings Licence handling IP settings vv w w w System maintenance To set the location of your TDX headend system click the arrow to the right of the Country field to open
10. Enter new password again gt Licence handling gt IP settings gt System maintenance To verify the new password enter the new password once more in the Con firm password field Settings Licence handling Rev 05 2011 C If you have bought licences to output services using e g IPTV you have to activate these licences in your TDX headend system using Licence handling in the Administration window To enter the Licence handling area click the arrow bracket to the left of Li cence handling Settings for TDX Service Tool pa Language settings Country settings Time zone settings vv w w Password settings Y Licence handling View licences and enter activation keys Serial number TDX unique ID Activation key 0492000012011020240 3187912C102F gt IP settings gt System maintenance Before you can activate a licence you have to contact Triax and provide in formation about the serial number displayed in the Serial number field and the ID displayed in the TDX unique ID field When Triax has received the ID of your TDX they will provide you with the ac tivation key Settings for TDX Service Tool Language settings Country settings Time zone settings Password settings Hv v v v License handling View licenses and enter activation keys Serial number 0492000012011020240 TDX unique ID 3187912C102F Activation key
11. Services used 0 10 RTP protocol Disabled It is possible to change the last digits of the IP address if for example you want to change the order of the services Note You can change the first digits of the IP address in the IP set tings area in the Administration window To change the last digits of the IP address click the field delete the existing digit s and enter the new digit s Rev 05 2011 C Status informa tion Rev 05 2011 C TDX Service Tool 1 Click the field 2 Delete the existing ZI digit s PN 3 Enter the new 239 0 0 3 digit s 239 0 0 4 239 0 0 5 TV 2 Syd 2 0 0 6 DR Ramasjang if 0 10 RTP protocol Disabled When you have selected the services you want you have to click the Submit button to enter this information in to the headend system and return to the Output window Remember to click the Apply button in the upper right hand corner to save new settings in the configuration Status information is placed at the bottom of the Configuration window The information displayed in the configuration window includes RTP protocol and services RTP protocol Informs whether or not you have enabled RTP in the IP settings menu in the Administration window Services used Tells you how many services out of the total number services your licence gives you access to you have output so far TDX Service Tool EB Multicast IP group setup Link 1 Group 1 239 0 0 1 2
12. systemcontroller src application tox unit initiator src CLTdxUnitinitiator Initialized FPGA type 0x01 with firmware build 0x03b8 major 0x00 minor 0x01 b INFO systemcontroller src application tdx_unit_initiator src CLTdxUnitinitiator Starting MAIN unit INFO Webinterface CLPolicyServer Load static failsafe policy settings INFO systemcontroller src application tox unit initiator src CLTdxUnitinitiator Hw watchdog keepalive timer started INFO systemcontroller src application system_manager src CLSystemErrorHandler System is in state ERROR INFO systerncontroller src application systern_manager src CLSystemErrorHandler System is in state ERROR INFO systemcontroller src application system manager src CLSystemErrorHandler System is in state ERROR INFO systemcontroller src application frontend_manager src CLTdxFrontendManagerTask DVB S frontend in slot 0 added INFO systemcontroller src application frontend_manager src CLTdxFrontendManagerTask Frontend in slot 0 Bootloader SW Ver 1 1 0 14460 FS INFO systemcontroller src application frontend_manager src CLTdxFrontendManagerTask DVB T frontend in slot 1 added INFO systemcontroller src application frontend manager src CLTdxFrontendManagerTask Frontend in slot 1 Bootloader SW Ver 1 1 0 14460 FS INFO systemcontroller src application frontend_manager sre CLTdxFrontendManagerTask Frontend in slot 0 S N Yg3 reed Q INFO systemcontroller sre application fronten
13. IP settings Configuration port Unit link 1 Unit link 2 Change IP subnet and default gateway address IP address 255 255 255 255 Subnet mask 255 255 255 255 Default gateway 255 255 255 255 Click the OK button to save the changes gt System maintenance Note You only need to change password language time zone country and IP addresses the first time you enter a new TDX headend system in order to set it up WARNING AII unsaved changes will be lost in case of a power cut Rev 05 2011 C System configuration Create a new To create a new configuration click the New configuration button in the Sys system config tem window uration Rev 05 2011 C Now a configuration file is created and the file is listed in the configuration list area TDX Service Tool System information Main unit Subunit 2 Last configured on web Last configured on TDX Mon Mar 21 12 08 58 2011 TDX XML A configuration file appears in the list after clicking on the New button You use the buttons below the configuration list area to manage configura tion files in your headend system Set active Click this button when you want to activate a selected configuration file New Click this button to create a new configuration file Delete Click this button to delete a selected configuration file Load to TDX Click this button to download a configuration file from your
14. and select input module for time and date to open the from Main Unit drop down list Time zone GMT 12 00 Eniwetok Kwajalein GMT 11 00 Midway Island Samoa GMT 10 00 Hawaii GMT 9 00 Alaska GMT 8 00 Pacific Time US amp Canada GMT 7 00 Mountain Time US amp Canada GMT 6 00 Central Time US amp Canada Mexico City GMT 5 00 Eastern Time US amp Canada Bogota Lima GMT 4 00 Atlantic Time Canada Caracas La Paz GMT 3 30 Newfoundland GMT 3 00 Brazil Buenos Aires Georgetown GMT 2 00 Mid Atlantic gt Licence handling GMT 1 00 hour Azores Cape Verde Islands gt IP settings GMT Western Europe Time London Lisbon Casablanca GMT 1 00 hour Brussels Copenhagen Madrid Paris GMT 2 00 Kaliningrad South Africa GMT 3 00 Baghdad Riyadh Moscow St Petersburg GMT 3 30 Tehran GMT 4 00 Abu Dhabi Muscat Baku Tbilisi GMT 4 30 Kabul GMT 5 00 Ekaterinburg Islamabad Karachi Tashkent GMT 5 30 Bombay Calcutta Madras New Delhi GMT 5 45 Kathmandu GMT 6 00 Almaty Dhaka Colombo GMT 7 00 Bangkok Hanoi Jakarta GMT 8 00 Beijing Perth Singapore Hong Kong GMT 9 00 Tokyo Seoul Osaka Sapporo Yakutsk Input module Main unit gt Password settings gt System maintenance Select the time zone you want to use in connection with your TDX headend system The time zone you
15. button TDX Service Tool version 1 3 33 0 to reboot the TDX headend system Reboot TDX system Note You can also reboot the TDX headend system by switching off the power manually Important When rebooting the TDX headend system or switching off the power the distribution of services to all your end users will be interrupted When the TDX system has been rebooted you close the Administration win dow and restart your Internet browser When you have restarted your browser you have to log into the TDX Service Tool if you need to make further changes Loading e gt ei Load to TDX In case you want to load a configuration file made using the TDX Configura tor from your computer laptop to your TDX system you have to use the Load to TDX button on the System tab TDX Service Tool eee no er System information Main unit Click the Load to TDX button Last configured on web Last configured on TDX Thu Mar 24 12 08 58 2011 TDX XML Click the Load to TDX button at the bottom of the System tab to display the Open window Open 2 x Look in d My Computer Od e Er See System C LI DVD drive D My Recent Documents My Documents My Computer My Network File name lo Places File type XML Files er VA In the Open window navigate to the folder where you saved the configuration file from the TDX Configurator Select the file then click the Open button to inclu
16. enter a new multicast IP address and a multicast port in the corresponding fields Settings for TDX Service Tool Language settings Country settings Time zone settings Password settings vv w w w License handling v IP settings Configuration port Unit link 1 Unit link 2 Change IP subnet and default gateway address IP address 192 168 0 200 Subnet mask 255 255 255 0 Default gateway 192 168 0 1 Enable RTP protocol LJ First 3 octets of multicast IP address 259 EA 9 Multicast port gt System maintenance Click to select RTP protocol Enter multicast IP address Enter multicast port Settings _e Click the Unit link 2 tab if you have connected an IPTV system or a second subunit to the Unit link 2 socket and enter an IP address subnet mask and default gateway and in connection with IPTV also a multicast IP address and a multicast port Important To make a changed IP address take effect you have to reboot the TDX headend system using the Reboot button in the Sys tem maintenance area or switch off the power Save settings When you have made the changes you want to make in the Administration window click the OK button at the bottom of the Administration window to save the changes and return to the System window Settings for TDX Service Tool pa Language settings Country settings Time zone settings Password settings Licence handling Hiv vv v v
17. selected is now displayed in the Time zone field To set time in accordance with the time zone click the arrow to the right of the Input module field to open the drop down list with all the input modules installed in your main unit Rev 05 2011 C Settings Password settings Rev 05 2011 C Settings for current TDX Service tool gt Language settings gt Country settings Y Timezone settings Change time zone and select input module for time and date from Main Unit Time zone GMT 1 00 hour Azores Cape V v Click the arrow to open the drop down list Input module Main 3 DVB T unit 1 DVB S 2 DVB S 3 DVB T 4 DVB T 5 DVB T 7 DVB T 8 DVB T 10 DVB T 11 DVB S 12 DVB S gt Password settings Licence handling IP settings System maintenance Select the input module you want to use for setting the time The input mod ule you selected is now displayed in the Input module field To enter the Password settings area click the arrow bracket to the left of Password settings To change password enter the old password in the Old password field Enter the new password in the New password field Settings for current TDX Service tool gt Language settings gt Country settings gt Time zone settings v Password settings Change password for TDX system Old password Il 1 Enter old password New password 2 Enter new password Confirm password 3
18. 0 2 Click the Start update button to start updating When updating the firmware the Firmware update status window will display information about status and errors as well as the progress of the update it self An update will take approximately 5 minutes Firmware update status window Select update type for selected firmware Replace all Update old packages Status Starting Update to version 1 7 1 13126 Unit 0 SC Finished writing image to disk0 TDXGui xap Unit 0 SC Finished writing image to sc spansion fpga Unit 0 BE 1 Finished writing image to gambe spansion fpga Unit 0 SC Unit 0 BE 1 Finished writing image to gambe AT45 backend Update done Errors detected 2 Errors Progress When you have finished updating the firmware you have to reboot the sys tem by clicking the Restart button in order to make the update effective Important When rebooting the TDX headend system the distribution of services to all your end users will be interrupted for a very short time Rev 05 2011 C Updating firmware Rev 05 2011 C Firmware update status window Select update type for selected firmware Replace all Update old packages Starting Update to version 1 7 1 13126 Unit 0 SC Finished writing image to disk0 TDXGui xap Unit 0 SC Finished writing image to sc spansion fpga Unit 0 BE 1 Finished writing image to gambe spansion fpga Unit 0 SC Finished writing im
19. 00 00 42 1970 Thu Jan 01 00 00 49 1970 Thu Jan 01 00 00 49 1970 Thu Jan 01 00 00 53 1970 Thu Jan 01 00 00 53 1970 Thu Jan 01 00 00 56 1970 INFO systemcontroller sre application tdx_unit_initiator src CLTdxUnitlnitiator System controller running FAILSAFE software version 1 8 0 14157 S N 04920000 a INFO systemcontroller src application tdx_unit_initiator src CLTdxUnitinitiator Ip address 255 255 255 255 INFO systemcontroller src application tdx_unit_initiator src CLTdxUnithnitiator Initialized FPGA type 0x01 with firmware build 0x03b8 major 0x00 minor 0x01 b INFO systemcontroller src application tdx_unit_initiator src CLTdxUnitinitiator Starting MAIN unit INFO Webinterface CLPolicyServer Load static failsafe policy settings INFO systemcontroller sre application tdx_unit_initiator src CLTdxUnitlnitiator Hw watchdog keepalive timer started INFO systemcontroller src application system_manager src CLSystemErrorHandler System is in state ERROR INFO systemcontroller src application systern_manager src CLSystemErrorHandler System is in state ERROR INFO systemcontroller src application system_manager src CLSystemErrorHandler System is in state ERROR INFO systemcontroller src application frantend_manager src CLTdxFrontendManagerTask DVB S frontend in slot 0 added INFO systemcontroller src application frontend manager src CLTdxFrontendManagerTask Frontend in slot 0 Bootloader SW Ver 1 1 0 14460 FS
20. 39 0 0 2 239 0 0 3 239 0 0 4 239 0 0 5 TV 2 Syd 239 0 0 6 DR Ramasjang 239 0 0 7 DR UPDATE Status information Information services used IO RTP protocol IPTV Delete IP group Rev 05 2011 C When you return to the Output window the configuration of the unit link1 socket is displayed in the IPTV list TDX Service Tool The names of the services you have selected a Link 3 tems A group of services Fae see ees has been configured EES Gn on unit link 1 Click to configure a new group of services If your licence s gives you access to select a large number of services it is possible to group the services in the IPTV list in order not to lose control of which services you have selected To configure a new group of services click the Setup button to open the Configuration window Select a number of services in the Configuration win dow click the Submit button to enter this information in to the headend sys tem and return to the Output window which will display the new group TDX Service Tool Type IP address Port 4 Link 1 3 Items The selected services Multicast 239 0 0 3 50176 DR1 DR2 TV 2 Syd lt gt have been divided into Multicast 239 0 0 8 50176 DR Synstolkning FOLKETINGET Syd 4 Link 2 0 Items If you want to remove a group of services and the associated configuration you can use the Delete button of the group in question in the IPTV wi
21. age to sc AT45 system Unit 0 BE 1 Finished writing image to gambe AT45 backend Update done Errors detected 2 Errors Click the Restart button to Progress reboot the headend system When you have rebooted the TDX headend system a message window is displayed asking you to restart your Internet browser P Please restart your browser application Cmn When you have restarted your browser you have to log into the TDX Service Tool in case you need to make any changes If your list of firmware updates needs to be tidied you can remove one or more of the previous firmware updates listed in the Change firmware window Select the firmware update and click the Delete package button Change firmware dialog pa IIT sort the flo 1 8 1 15259 1 8 1 15261 1 8 1 15262 2 Click the Delete Package button The firmware update is removed from the list Rebooting Reboot system lf you need to switch the TDX headend system off and then immediately start Rev 05 2011 C it again you can use the Reboot button in the System maintenance area of the administration window Click the Reboot button to reboot the TDX headend system Settings for TDX Service Tool Language settings Country settings Time zone settings Password settings Licence handling IP settings System maintenance Open log file in new window Firmware version in use 1 8 1 15262 change Click the Reboot
22. computer laptop to your TDX system More informa tion about downloading see Load to TDX on page 45 Load from TDX Click this button to upload the configuration file from the TDX system to your computer laptop More information about uploading see Load from TDX on page 46 To activate a new configuration file select the file and click the Set active button and the Apply button to save the configuration file System configuration Save configu An important button when you change your configuration of the headend ration system is the Apply button placed in the upper right hand corner of the TDX Service Tool window TDX Service Tool System information Main unit Click the Apply button to save the changes Apply Whenever you have made changes in your configuration Apply on the Apply button turns red to tell you that you have unsaved changes that need to be saved Click the Apply button to save the changes When chang es have been saved the Apply text looses the red col our WARNING All unsaved changes will be lost in case of a power cut Change system When you change an existing configuration of your headend system the TDX configuration Service Tool updates the date and time of the configuration file when you save the changes using the Apply button TDX Service Tool Date and time of configuration file have been updated Rev 05 2011 C IPTV CA IPTV w
23. d_manager sre CLTdxFrontendManagerTask Frontend in slot 1 SIN Y 2 ce d ce E deed INFO systemcontroller src application frontend_manager src CLTdxFrontendManagerTask Frontend in slot D Application SW Ver 1 8 1 15262 INFO systemcontroller src application frantend_manager src CLTdxFrontendManagerTask Frontend in slot 1 Application SW Ver 1 8 1 15262 INFO systemcontroller src application frontend_manager src CLTdxFrontendManagerTask Frontend in slot O changed state to not locked In case you need to save the log after having looked at the file in the Note pad window you can use the Save as command in the File menu of the Note pad window If you only want to save the log file when you open the File Download win dow click the Save button to open the Save as window Log file Save As 12 x Save in emm sl Ba E CJ My Documents LI 2 My Computer My Recent 3 My Network Places Documents 7 3 Desktop My Documents I My Computer ng n My Network File name tdxlog tet pa Places Save as type Text Only x Cancel Z Navigate to the folder where you want to place the log file Click the Save button to save the file Save As Lex Save in 2 My Computer el O Lo tae Se System C Te 1 Navigate to the desired My Recent folder Documents 3 Desktop My Documents My Computer kA ccoo E 2 Click to save the file Save as type Text Only X Cancel Clicki
24. de the file in the configura tion list on the System tab Rev 05 2011 C Load from TDX Rev 05 2011 C Loading Open 2 x Look in CJ Triax 1 Navigate to the desired folder My Recent Documents 3 Desktop 2 Select the file My Documents a 3 Click to open the file My Computer wy My Network File name TDX_1 2 25 22 4 xml lt Open Places File type XML Files 7 Cancel J A The configuration file will now be listed in the configuration list area If the name of the new configuration file is identical to the existing configura tion file a number in brackets will be added to the name of the new file You can save a configuration file from your TDX headend system to your computer laptop in case you want to use it in another TDX headend system that is identical to the one from which you want to save the configuration file If however you load a configuration file into a dissimilar TDX system you will have to reconfigure all those modules that deviate from what is specified in the configuration file All deviating modules will be marked in red To save a configuration file on your computer laptop you have to use the Load from TDX button on the System tab TDX Service Tool System information Main unit Click the Load from TDX button Click the Load from TDX button at the bottom of the System tab to display the Save As window Loading Configu
25. emove it from the module slot Each input module has a LED on the front to signal whether the module is locked or not to the frequency that it is set to receive at Green flashing The module has not been configured yet Green No errors and the tuner is locked to the frequency Red Error and the tuner is not locked to the frequency No colour Power has not been switched on LED When you update the software of a module the status LED provides you with information about the updating process Rev 05 2011 C Input Rev 05 2011 C Orange Boot loader state Temporary off Initiation of the software update Temporary green Every time the modules receives a valid data package Repeated until the update is completed without errors Red Software update failed A label is provided on the input module where you can write the information regarding the configuration of the module Besides the information that you write on the label the module type and code number are also displayed on the label Label On one of the other sides of the module you will find a label with the bar code printed on it When all the required input modules have been installed you can connect the input signal cables one by one to the input modules It is also possible to make a loop through from one input module to another using a cable When connecting the input signal cables you have to decide whether you want the cables to go from the t
26. end unit in a rack or ona unit before you mount it wall you have to position the brackets accordingly on the headend unit To mount the headend unit on a wall unit before you mount it Mounting Rev 05 2011 C Earthing Input Earthing The headend unit must be earthed before you install any modules i e you have to connect each headend unit to the ground with a wire from the Earth terminal socket Wire connected to the ground to make the unit earthed Input modules Itis possible to install up to 16 input modules in a headend unit Loop through It is optional in which slots you place the individual input modules in the input section For convenience each slot has been given a number An overview of the slot numbers has been placed on the inside of the door of each unit Note Slot no 1 is placed in the top left hand corner of the input section when you face the front of the unit INPUT 145 9 113 2 6 10 14 3 7 11 15 4 8 12 16 Rev 05 2011 C a Input E You install an input module by sliding the module into a module slot in the upper section of the headend unit and click the module into place 1 Slide the module fl into a slot 2 Push the module till the fastener clicks into place You can remove an input module from a module slot without using any tools just use your fingers 1 Press the fastener downwards 2 Pull the module outwards to r
27. ess 192 168 0 100 Subnet mask 255 255 255 0 Default gateway 192 168 0 1 gt System maintenance If your TDX headend system is part of a network you have to change the IP address of the configuration port to include the main unit in the network To enter the IP settings area click the arrow bracket to the left of IP settings Enter new IP address Enter new subnet mask Enter new default gateway Settings e z_ 759 Enter a new IP address subnet mask and default gateway in the correspond ing fields Important To make a changed IP address take effect you have to reboot the TDX headend system using the Reboot button in the Sys tem maintenance area or switch off the power Note In case you need to reset the IP address to the factory de fault address you have to use the ID switch For information about how to use the ID switch to reset the IP address see ID switch on page 17 To output services using an IPTV system or to include a subunit in a network you have to enter an IP address subnet mask and default gateway for each unit link socket you use With regard to IPTV you also have to enter a multicast IP address and a mul ticast port for each unit link socket you use To enter the IP settings area click the arrow bracket to the left of IP settings Now click the Unit link 1 tab to display the relevant fields Settings for TDX Service Tool Language settings Country setting
28. file Name tdxlog txt Type Tekstdokument 2 77MB From 192 168 0 100 Open Click to save the log file harm your computer If you do not trust the source do not open or save this file What s the risk DP While files from the Internet can be useful some files can potentially In the File Download window you can either open the log file or save the file to your laptop computer If you want window to open the log file click the Open button in the File Download P tdxlog 1 txt Notepad 5f x Filer Rediger Formater Vis Hj lp Thu Jan 01 00 00 39 1970 Thu Jan 01 00 00 39 1970 Thu Jan 01 00 00 39 1970 Thu Jan 01 00 00 39 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 42 1970 Thu Jan 01 00 00 42 1970 Thu Jan 01 00 00 42 1970 Thu Jan 01 00 00 42 1970 Thu Jan 01 00 00 49 1970 Thu Jan 01 00 00 49 1970 Thu Jan 01 00 00 53 1970 Thu Jan 01 00 00 53 1970 Thu Jan 01 00 00 56 1970 Thu Jan 01 00 00 56 1970 Thu Jan 01 00 00 58 1970 Thu Jan 01 00 00 39 1970 Thu Jan 01 00 00 39 1970 Thu Jan 01 00 00 39 1970 Thu Jan 01 00 00 39 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 40 1970 Thu Jan 01 00 00 42 1970 Thu Jan 01 00 00 42 1970 Thu Jan 01 00 00 42 1970 Thu Jan 01
29. incoming signals from input modules initially arrive in the TDX pool From this pool they can be converted into any output signals you require while simultaneously being fed to several different output modules Besides the configuration of input and output modules can be readily changed at any time The ability of converting any input signal to any output signal makes the TDX headend system uniquely flexible efficient and economical Unpacking Box content Included in the box you will find the TDX headend unit key brackets Torx key screws a power lead and a user guide Everything you need to do in connection with the headend unit you can do from the front of the unit Unit exterior In order to make it easy for you to work with a TDX headend unit you can re move the door and the top from the unit Top that you can slide off when door is open Door that you can lift off when it is open a e a 2 Ci a A a 999990082 Air vents Note Before you leave a headend system the extractor fan in the output section must be clicked into place in the middle of this section and the door must be closed due to heat and EMC Rev 05 2011 C TDX Unit CA Unit interior Inside the TDX unit the interior is divided into two parts an upper part input section containing all the input modules and a lower part output section containing all the output modules Input section Output section
30. indow The TDX headend system includes basic IPTV functionality which enables you to deliver services using the architecture and networking methods of the Internet Protocol Suite over a packet switched network infrastructure e g the Internet and broadband Internet access networks To output services using IPTV click the IPTV tab in the TDX Service Tool to display the IPTV window The first time you display the IPTV window in a new configuration the list ar eas below Link 1 and Link 2 representing the unit link 1 and 2 sockets on the main unit will be empty TDX Service Tool Refers to the unit link AU 1 and 2 sockets on lt the main unit 4 Link 2 0 Items To display the Configuration window click the Setup button of the unit link socket to which your IPTV system is connected TDX Service Tool Type IP address Port LI Juna Click the Setup 4 Link 2 0 Items button Rev 05 2011 C IPTV CA IPTV configura The first time the TDX Service Tool displays the Configuration window in a tion window new configuration the fields in the window will either display a default value or be empty TDX Service Tool Tabs E E AAE PEO TD Gowns Gan Buttons Back button Link and Group ID Field Services button Combination area Submit button Status information area Type To select the desired type of communication click the arrow to the right of the Type field to open the drop d
31. ls you when TDX Service Tool is not communicating properly with the TDX headend system Green The TDX Service Tool and your TDX headend system exchange infor mation without any problems Red The TDX Service Tool and your TDX headend system are not commu nicating properly Press the F5 button to refresh the internet browser and re new communication between the TDX Service Tool and the headend system en TDX Service Tool Communication icon red no communication TDX Service Tool Communication icon green communicating Administration To change password and language you have to open the Administration win window Rev 05 2011 C dow by clicking the Admin button in the top right hand corner of the System window TDX Service Tool O han Click the System Information Administration button Main unit Click the Admin button to open the Administration window Administration window Language When you have opened the Administration window the Language settings settings area is displayed Settings for TDX Service Tool pa v Language settings Change language for TDX Service Tool Current language English Country settings Time zone settings Password settings Licence handling IP settings System maintenance To select another language click the arrow to the right of the Current lan guage field to open the drop down list with the languages you can choose from
32. mbled Syd Tv2 Film HD Service sources Main Unit cam 1 B Main Unit input 2 Main Unit input 4 Main Unit cam 1 B Main Unit input 2 Main Unit input 2 Main Unit input 1 Main Unit input 2 Main Unit input 3 Main Unit cam 1 B Main Unit input 3 Main Unit cam 1 B Main Unit input 1 Main Unit input 4 Select service s 1 Click the square to select a service 2 Click OK to save and leave the window Click OK to return to the Configuration window when you have selected the services you want to output Rev 05 2011 C IPTV lt eEEERRR O EB aaa If you have selected more services than your licence s entitles you to select you will get a warning and the services that exceed the number of services you can select will be deselected All activated IP services are used please aquire additional licences to add more es Note When you have selected a service this service will no longer be available in the TDX pool for the unit link in question In the Configuration window the combination area displays the services you have selected and the IP addresses that have been allocated to each of the services TDX Service Tool CEB Multicast IP group setup Link 1 Group 1 Configuration Type Multicast v Select input 239 0 0 1 239 0 0 2 239 0 0 3 239 0 0 4 239 0 0 5 TV 2 Syd 239 0 0 6 DR Ramasjang 239 0 0 7 DR UPDATE Status information
33. nance area click the arrow bracket to the left of System maintenance Click the Change button to the right of the version number of the current firmware to open the Firmware window Settings for TDX Service Tool Language settings Country settings Time zone settings Password settings Licence handling IP settings Y System maintenance Open log file in new window Click the Change button to open the Firmware version in use 1 8 1 15262 Chance r Firmware window TDX Service Tool version Reboot TDX system Updating firmware The Firmware window lists the current version of your TDX firmware as well as previous versions of the firmware Change firmware dialog x 1 8 1 15256 1 8 1 15258 Previous versions of firmware 1 8 1 15259 1 8 1 15261 The current and active version of firmware Click the Upload file button Click the Upload file button to display the Open window Open 2 x Look in dJ My Computer O e E amp System C A LI DVD drive D My Recent Documents Desktop a My Documents My Computer 9g My Network File name GG N Places File type bkis o Cancel 1 In the Open window navigate to the folder where you saved the update file when you downloaded it from the Triax home page Select the file Click the Open button to include the file in the list in the Firmware window Rev 05 2011 C Updating firmware Open
34. ndow Click the Delete button of the group you want to remove A message window is displayed asking you to confirm that you want to remove group Log file Log file Rev 05 2011 C You can save a log file that lists actions that have occurred in the TDX head end system This may be useful in case of problems with your TDX headend system The size of the log file will be adequate for listing all actions that have oc curred in the system for a couple weeks To save a log file on your computer laptop you have to open the Administra tion window Click the Admin button in the top right hand corner of the TDX Service Tool window to open the Administration window TDX Service Tool et iii ii Click the System information Administration button Main unit Subunit 2 Last configured on web Last configured on TDX Note Thu Mar 24 12 08 58 2011 TDX XML To enter the System maintenance area click the arrow bracket to the left of System maintenance Settings for TDX Service Tool Language settings Country settings Time zone settings Password settings License handling IP settings System maintenance Firmware version in use 1 9 1 16649 Change TDX Service Tool version 1 4 2 0 Reboot TDX system Reboot Log file Rev 05 2011 C In the System maintenance area click the Save log button to open the File Download window Click to open the log file Do you want to open or save this
35. ng the Save button displays the Download window Download complete _ 0 x mu Download Complete tdxlog txt from 192 168 0 100 IIIIIIIIIII II III III III III III III AA AA AA AN Downloaded 2 77MB in 1 sec Download to C Documents and Settings tdxlog txt Transfer rate 2 77MB Sec TT Close this dialog box when download completes Open Open Folder Report an unsafe download gt I SmartScreen Filter checked this download and did not report any threats When the log file has been downloaded and saved you can open the log file open the folder where you have saved the log file or just close the window When you close the Download window you return automatically to the Ad ministration window Close this window by clicking the OK or Cancel button Rev 05 2011 C Updating firmware Update firmware Rev 05 2011 C When firmware updates for your TDX system is available on the Triax home page www Triax com you can download these updates to your computer and then upload the updates to your TDX system using the Administration window Click the Admin button in the top right hand corner of the TDX Service Tool window to open the Administration window TDX Service Tool 168 tooo arn Click the System information Administration Main unit button Subunit 2 Last configured on web Last configured on TDX Note Thu Mar 24 12 08 58 2011 TDX XML To enter the System mainte
36. nits you have to insert factor Plugable SFP copper or SFP fibre optic transceivers into the unit link sockets on both SFP the main unit and the subunit s When you insert an SFP transceiver into a unit link socket you have to open the lock mechanism on the transceiver before you insert it into the unit link socket Click the lock mechanism into place to lock the transceiver in the socket SFP transceiver copper 1 Open the lock before you insert the transceiver into the unit link socket Unit link sockets Losk 2 Click the lock into place when you have inserted the transceiver into unit link socket SFP transceiver fibre optic Note You also have to insert SFP copper or SFP fibre optic transceiv ers into the unit link sockets on the main unit if you want to use the sockets to output services using an IPTV system Rev 05 2011 C Connecting Units Connecting To connect the main headend unit with one or two subunits you pull Cat5 ca units bles SFP copper transceiver or 850 or 1310 cables depending on the SFP fibre optic transceiver from one unit to another following the guidelines in the table below regarding the maximum length of the cables Par Package Data rate Reach Application 492086 Copper SFP 1000Mbps 100m Gigabit Ethernet EOLT C12 02 RJ45 via Cat5 cable 492087 Fiber 850nm Gigabit Ethernet EOLS 8512 MXX LC 492088 Fiber 1310nm Gigabit Ethernet EOLS 1324 02XX LC If y
37. og in button the System window is displayed Note Every time you set up a new headend system you have to start from scratch in the TDX Service Tool meaning that you will have change the default password select which language you want to use in the TDX Service Tool and change the IP address if your TDX headend system is part of a distribution network System window _ _o o System window The System window contains a number of tabs and buttons information about connected units and a configuration list area TDX Service Tool Communication icon Tabs Buttons System information Main unit System information list Configuration list area Buttons Communication icon Informs you when the communication between the TDX system and theTDX Service Tool fails Tabs Via the tabs you enter the different stages of set ting up your input and output modules Buttons You use the buttons in the upper right hand corner in connection with the TDX Service tool whereas you use the buttons below the configuration list area in connection with the entire setup itself System information This list displays whether any subunits are con list nected to the main headend unit and also whether they are up and running Configuration list This list area will display your present configuration area of your headend system as well as the previous versions of the configuration Note In connection with every new headend system the System win d
38. op of the headend unit to the input modules or from the side of the unit to the modules Input signal cable connected to an input module from the side of the headend unit Loop through Input signal cable connected to an input module from the top of the headend unit Ta Output _ _ _ _r_T_y_ __ _q_ EE 5Wj Output mod It is possible to install up to 6 output modules in a headend unit Each output ules module consists of 4 RF channels Depending on the type of module you can add up to 2 CAM modules on each output module In the future it may also be possible to add an Aux module for future options to the output section It is optional in which slots you place the individual output modules For convenience each slot has been given a number and an overview of the slot numbers has been placed on the inside of the door of each unit Note Slot no 1 is placed in the top left hand corner of the output section when you face the front of the unit OUTPUT 13 43 of SF 3 6 You install an output module by sliding it into a slot in the lower section of the headend unit and click it into place into a slot and click it into place You release an output module from a slot by using the lock mechanism that is placed to the right of the modules in the output section Move the lock mechanism slightly to release the module Rev 05 2011 C Rev 05 2011 C Output
39. ou only connect one subunit to the main unit you pull a cable from the unit link 1 socket on the main unit to the unit link 1 socket on the subunit Main headend unit Rev 05 2011 C Connecting units _ _ TTT Rev 05 2011 C If you have to connect two subunits to the main unit you pull a cable from the unit link 1 socket on the main unit to the unit link 1 socket on subunit 1 Then you pull a cable from unit link 2 socket on the main unit to the unit link 1 socket on subunit 2 Next you connect the first subunit to the second subunit using the unit link 2 sockets on subunits 1 and 2 Main unit Main unit 1 Cable from unit link 1 socket to unit link 1 socket on subunit 1 2 Cable from unit link 2 socket to unit link 1 socket on subunit 2 Subunit 1 Subunit 1 1 Cable from unit link 2 socket t S s unit link 2 socket on subunit 2 Subunit 2 ID switch Rev 05 2011 C ID Switch When you have connected the main unit and the subunits you have to set the IDs of the main unit and the subunits using the unit ID switch on the units You set the main unit to 0 subunit 1 to 1 and subunit 2 to 2 You have to use a small scre
40. ow in the TDX Service Tool will display an empty configuration list area Rev 05 2011 C System window rr __ i System informa To get detailed information about the individual units you can click the unit tion in question in the System information list and open the System information window TDX Service Tool Click the unit name to open the System Subunit 2 information nn wi n d OW Thu Mar 24 12 08 58 2011 TDX XML In the System information window you get information about system errors which software version each of the input and output modules uses and the MAC addresses System information for unit Show detailed system information for selected unit 4 System errors 3 items System errors Unit error Error on input module 512 Input module 3 error Missing input 8 4 Software versions 7 items Unit SW Version 1 8 1 15262 Input 1 SW Version 1 8 1 15262 Input 2 SW Version 1 8 1 15262 Software versions GIO SN i Input 4 SW Version 1 8 1 15262 Output 1 SW Version 1 8 1 15262 Output 2 SW Version 1 8 1 15262 4 MAC adresses 3 items MAC Etho 00 50 C2 B2 50 9A MAC addresses MAC Link1 00 50 C2 B2 50 9B In connection with errors in your TDX headend system you can use the Sys tem information window as starting point for locating the errors Rev 05 2011 C System window _ rr m __r____m NA Communication icon The colour of the communication icon tel
41. own list with the types you can choose from Select the type you want to use Select input To select services click the Services button next to Select input label to open the Select services window Note If you have selected Multicast in the Type field you can only output one service on each IP address TDX Service Tool a Multicast IP group setup Link 1 Group 1 Configuration Click the Service button Rev 05 2011 C Select services Select service s from list CANAL FILM HD_descrambled DR HD DR HD DR HD descrambled DRK DR Ramasjang DR Synstolkning DR UPDATE SVT1 HD SVT1 HD_descrambled SVT2 HD SVT2 HD_descrambled Syd Tv2 Film HD Service sources Main Unit cam 1 B Main Unit input 2 Main Unit input 4 Main Unit cam 1 B Main Unit input 2 Main Unit input 2 Main Unit input 1 Main Unit input 2 Main Unit input 3 Main Unit cam 1 B Main Unit input 3 Main Unit cam 1 B Main Unit input 1 Main Unit input 4 Select O In the Select Services window you can select the service that you want to output To select one or more services click the check box square to the right of the service you want Select services Select service s from list Services CANAL FILM HD_descrambled DR HD DR HD DR HD_descrambled DRK DR Ramasjang DR Synstolkning DR UPDATE SVT1 HD SVT1 HD_descrambled SVT2 HD SVT2 HD_descra
42. ration of modules Rev 05 2011 C Save As 21 xi Save in dJ My Computer OFF Cae My Recent Documents nj paa My Network File name v Places Save as type XML Files 7 Cancel Zi Navigate to the folder where you want to save the configuration file Enter the name of the configuration file in the File name field Select file type in the File type field Click the Save button to save the file Save As 2 x 1 Navigate to the desired folder 2 Enter file name 3 Select file type 4 Click to save the file My Computer Na x My Network File name TDX_1 2 25 A xml PI Save as type You return automatically to the System tab when you have saved the con figuration file For information on how to configure the different input and output modules please read the user guides that are included with the different modules Your notes w fil ic i i ig Your notes Rev 05 2011 C TRIAX 891072 05 2011 C 7 p Lad f 1 mi 4 ILA AV po NG a ee Lk z O TRIAX your ultimate connection
43. ributes the RF channels from the output modules Test point 20 dB Configuration port Aux 1 amp 2 Unit link 1 amp 2 Unit ID switch Secure Digital SD card Rev 05 2011 C using an F connector RF test point of output 20 dB Note When you attach F connectors to the RF output and Test point sockets you have to be very careful when you tighten the F connec tors or you may destroy the sockets Ethernet configuration port for setting up the head end system Connector type is RJ 45 and cable type is Cat5 Use a computer laptop with the software recommended below to configure the system Recommendations Operating system Windows XP or above Browser Windows Internet Explorer version 6 0 or above Additional software Microsoft Silverlight Runtime version 3 0 or above For future use Connects the main unit with subunits 1 and 2 Switch for setting the ID of the main unit and the two subunits Memory card for storage of the system configura tion Placed in a slot behind the front cover Mounting the Uni 296669900 screw the brackets to the back of the 3 9909900009 098999900 299999906 BG PTT 255 HA TR Brackets at the front of the unit Brackets at the back of the unit LT To mount the headend unit in a rack screw the brackets to the front of the Depending on whether you want to mount the head
44. s Time zone settings Password settings License handling vv w w w w IP settings Configuration port Unit link 1 Click the Unit link 1 tab to display the fields below Change IP subnet and default gateway address IP address 255 255 255 255 Subnet mask 255 255 255 255 Default gateway 255 255 255 255 Enable RTP protocol First 3 octets of multicast IP address 239 0 0 Multicast port 50176 gt System maintenance Enter a new IP address subnet mask and default gateway in the correspond ing fields Rev 05 2011 C Settings Rev 05 2011 C Settings for TDX Service Tool Language settings Country settings Time zone settings Password settings vv w w w License handling v IP settings Configuration port Unit link 1 Unit link 2 Change IP subnet and default gateway address IP address 192 168 0 200 Subnet mask 255 255 255 0 Default gateway 192 168 0 1 Enable RTP protocol First 3 octets of multicast IP address LL Multicast port gt System maintenance Enter new IP address Enter new subnet mask Enter new default gateway In connection with IPTV the fields at the bottom of the area are needed as well Click the Enable RTP protocol check box if you want to use Real time Trans port Protocol in your IPTV system In case you cannot use the default values displayed in the two fields
45. the drop down list that contains the countries you can choose from Rev 05 2011 C Settings Time zone settings Rev 05 2011 C Settings for TDX Service Tool gt Language settings v Country settings Change location for the TDX installation Current location Time zone settings Password settings Licence handling IP settings System maintenance United Kingdom Denmark Spain Italy Norway Sweden Finland Germany Portugal France Poland Hungary Greece Other country Click the arrow to open the drop down list Select the country in which your TDX headend system is located The coun try you selected is now displayed in the Country field To enter the Time zone settings area click the arrow bracket to the left of Time zone settings Settings for TDX Service Tool gt Language settings gt Country settings v Time zone settings Change time zone and select input module for time and date from Main unit Time zone Input module Main unit gt Password settings gt Licence handling gt IP settings gt System maintenance 1 DVB T Settings _ 5 To set the time zone of your TDX headend system click the arrow to the right of the Time zone field to open the drop down list with the time zones you can choose from Settings for current TDX Service tool 23 gt Language settings Y Time zone settings Click the arrow Change time zone
46. ve to connect your laptop Windows based to the RJ45 socket on the main headend unit using a Cat5 cable The Triax TDX Digital Headend system uses the programmes below and in addition to access the TDX Service Tool Microsoft Silverlight Runtime ver sion 3 0 is required Recommendations Operating system Windows XP or above Browser Windows Internet Explorer version 6 0 or above Additional software Microsoft Silverlight Runtime version 3 0 or above To access the TDX Service Tool open your web browser on your laptop and input the following IP address in the web address bar http 192 168 0 100 and press enter Note Your laptop has to use a static IP address in order to access the TDX Service Tool using the above mentioned IP address Use a Cat5 cable to connect a laptop to the setup port on the main unit Log in Log in Rev 05 2011 C When you have loaded the TDX Service Tool from the TDX headend system to your laptop computer the Login window of TDX Service Tool is displayed TDX Service Tool 1 Enter your password 2 Press the Login button The first time you want to log in to your TDX headend system you have to enter the default password The default password is triax1234 You can change the default password as soon as you have logged in to your headend system More information about changing passwords see Pass word settings on page 29 When you have pressed the L
47. wdriver to move the arrow on the ID switch to the required ID number Configuration Unit link 1 amp 2 port Aux 1 amp 2 ID switch Move arrow to required number on ID switch In case you need to reset the IP address of a headend unit i e to return to the factory default address you use the ID switch To return to factory default settings do the following e Switch off the power to the main unit e Set the ID switch on the main unit to 7 then switch on the power The four LEDs flash red and yellow until the process of resetting the IP address has been completed If the reset process has been successful the LEDs will turn green If the reset process fails the LEDs will turn red e Switch off the power to the main unit e Set the ID switch on the main unit back to the initial setting e Switch on the power to the main unit Now you have reset the IP address to the factory default address For information about how to change a default IP address see IP settings on page 31 Power amp RF Power and RF Connect each headend unit to a combiner using RF cables from the RF out output put socket to the combiner Next you connect each headend unit to the mains with a power lead from the power socket to the mains Power leads connecting to the mains RF cables connecting to a combiner Main unit Combiner RF cables