Home
INSTALLATION AND USER GUIDE
Contents
1. Ar ISLI DOUBLE TECNOLOGY OUTDOOR DETECTOR WITH ANTIMASKING SYSTEM INSTALLATION AND USER GUIDE Rev 3T08MV TECHNICAL CHARACTERISTICS Wall mount Detection length 12m 7 5 Microwave frequency 24 125 GHz Microprocessor technology DSP Digital Signal Processing Detection length From 0 30 to 12m Horizontal detection area IR 7 5 MW 32 Vertical detection area IR 90 MW 80 Curtain area characteristics 2 10m 25cm 130cm Installation height 2 1m wall or windows mount Detection technology Adjustable AND OR Power supply 10 15 Vcc Maximum consumption 25mA Minimum consumption 1104 Alarm relay time 5sec commutation Antimasking relay time TAMPER relay Open relay when cover removed Sensitivity Adjustable through trimmer Microwave sensitivity Adjustable through trimmer Max detection length Adjustable through dip switch Led indicator Enabled disable through DIP Switch Alarm memory Yes RF interference No Alarm up to 2GHz Led indicator purpose MW gt yellow PIR gt green Alarm gt red Operating temperature Auto compensation Cover color Art 9452 gt white Art 9454 gt brown Dimension 37 x 125 x 40m WARNING _ To avoid the risk of damaging the product never touch the PIR sensor
2. with hands Use a clean and soft cloth to clean the sensor GENERAL DESCRIPTION Remove screw plastic protection in the upper side of detector using a screw driver Angular reversible mounting bracket Wall mounting bracket WIRING Clamp description and purpose 12V Positive 12Vcc O fav AS GND GND negative jen as _ AMK Antimasking Output N C jamk MEM AS TAMPER N C AMK AL MEM Inhibition input and alarm memory enabling Co AL positive To saoo AL Alarm output N C LED indicator fage LD4 Red Led alarm LD5 Yellow Led microwave LD6 Green Led IR Trimmer MVY Range L Ds O IR Range IR Range IR range adjustment MW Range MW range adjustment oO DIP Switch SW1 O OW F ox LLE DIF O O DIP 1 2 3 4 Antimask IR ANTIMASK Led ON Enabled ANP ENABLED Enabled Q Q Antimask IR ANTIMASK Le
3. d OFF OR Disabled DISABLED Disabled D O JUMPER JP1 It is possible to set up detector for external or internal use using JP1 Jumper as described in the following chart JP1 plugged in External use setup more stability more power consumption JP1 plugged out Internal use setup more sensitivity less power consumption DETECTION LENGTH CHART 4 Lateral view Top view LED indicator MEM input In case of alarm or masking attempt a positive signal on this clamp shows the following events LIGHTED ON FLASHING IR detection no GREEN LED alarm MW detection YELLOW LED no alarm sep PORTEN EED Ao REDE VEECOW EER ee RED GREEN YELLOW IR MW detection alarm IR antimask detection GREEN and RED LED enabled AMK output RED YELLOW LED MW antimask detection enabled AMK output RED YELLOW GREEN IR MW antimask detection enabled AMK output N B In case both masking and alarm condition occur first LED will light on then they will start flashing GENERAL INSTALLATION GUIDE A AN SONENSSSNSSSNSNSSENSNSS Perimeter protection E z SAMin ARMSNNANNANNASNANSS Windows pr
4. f environmental conditions when control panel will be activated again DETECTION OPTIONS Mw antimask When this function is enabled AMK output activates if an obstacle remains in front of detector about 25sec e IR antimask When this function is enabled AMK output activates if an obstacle remains in front of detector A IR active signal will be checked out to verify this condition IMPORTANT NOTICE We suggest to do not activate Mw Antimask function if detector is installed outside where it can be exposed to rain snow etc AND Detector will be in alarm only if MW and IR are both in pre alarm condition OR Detector will be in alarm if MW or IR are in pre alarm condition
5. otection Windows and door protection Installation To avoid troubles on the detector it is necessary to check what follows When the detector is powered on LED indicator will flash alternatively stabilization time After that GREEN LED will flash fast and in the end YELLOW LED will flash fast GREEN LED flashing fast means that detector is acknowledging environmental conditions necessary for Beam antimask function YELLOW LED flashing fast means that detector is acknowledging conditions necessary for MW antimask function This acknowledging phase is necessary to evalue default conditions no masking condition so that any other condition can be considered as a masking attempt During this procedure do not stay in front of detector and do not put any obstacle between detector and covered area When detector will stop flashing it will start working normally e GREEN LED will show pre alarm condition IR e YELLOW LED will show pre alarm condition MW e RED LED will show detector alarm condition IR When a positive signal is present on MEM clamp usually connected to Off clamp of some control panels LED indicator are always lighted off and detector will be not working If an alarm occurs alarm memory will be shown as described in the above chart When control panel will be activated again detector will start working normally If a masking alarm occurs detector will repeat acknowledgment o