1. PSR20 type solar charge controller 12 24 V 20A an Panelectron Dear Customer Thank you for buying our product You have bought one of the most powerful compact and reliable units of its class Please read the operating instructions carefully before use WARNING Safety Instructions Do not use the unit In places which are dusty damp in a high humidity area over 80 rel humidity at temperatures above 50 C in areas containing inflammable materials liquids solvents gas Do not immerse in water Use only in closed dry areas Should the unit fail to operate or show signs of not operating properly unplug immediately and make sure that the unit is not put into further operation Do not use the unit when visible signs of damage due to transport or inadequate storage are noticeable To prevent the risk of explosion by overcharging install the battery in a well ventilated place Use only solar cells as power source To prevent a short circuit between solar charger unit and battery install a fuse on the positive battery pole Equipment which on account of its function must not be switched off by means of load disconnection e g navigation lights must be connected directly to the battery and fused When recharging sealed lead acid batteries switch off the gas control see Factory settings Follow installation instructions strictly when connecting the unit The unit should be disconnected i
2. regulator uses a lower 14 1V charging voltage which will be maintained during the entire charging cycle with the charging current gradually reduced This would protect batteries sensitive to higher charging voltage Temperature compensation The temperature compensator circuitry adjusts and regulates the final charging voltage and gas formation of the batteries in accordance with the temperature in area of use The sensor has a ca 1 5m long connecting cable sensor should be attached to the battery case with the help of a piece of tape Connection and operating elements O O 1 Green LED Charging indication illuminates yen sae when the battery is being charged At night protection Ladung 1 there is no indication while there is no iene ne Lastaus 2 charging current from the solar modules 2 Red LED Load disconnected In case of battery deep discharge the loads are AY oe disconnected As soon as the battery is p t F recharged the dc loads are switched back on O m 9 9 SS SS O and the LED stops illuminating 3 Temperature sensor i i 3 s 4 load connection terminals 5 battery connection terminals 6 solar module connection terminals 7 20A fuse prevention against reversed polarity connection of battery terminals load terminals and overloading Warning Should the terminals be reverse polarity connected to the load output can units lt 20 A fused be c
3. Two LEDs indicate the operating status under different circumstances and possible mal functions in the Solar Charger Unit oF __ nochagingcurent CO ee activated ae ee current connected load short circuit load does not work 2 ON OFF charger current green LED intensity reduces as battery being charged full status is being reached green LED lights discharged load is disconnected no charging current check terminals and fuses Battery is dee discar hi pane load reconnects automatically a eins after reaching reset voltage current present Specifications Normal voltage 12 24V automatic battery voltage recognition Charging current solar cells 20 A Max Load 20 A Max Power use 4mA Temperature sensor on external cable Gas control deactivated factory setting Boost charge voltage 14 5 V 29 V Float charge voltage 13 7 V 27 4 V Charging voltage restart at 12 4 V 24 8 V Gas control activated Charging voltage 14 1 V 28 2 V Deep discharge disconnection DC output disconnected at 11 1 V 22 2 V DC output reconnected at 12 6 V 25 2 V Temp compensation 4 mV K cell Fuse 20 A Temperature range 25 C 50 C Measurements L x B x H 175 x 107 x 45 mm Weight 330 g without packaging Subject to alteration July 2010 Panelectron Ltd Oszt ly u 16 18 E H 1087 Budapest Hungary Tel Fax 36 1 215 9116 E mail info panelectron hu URL http www panelectron hu OPERATING INSTRUCTIONS CE
4. ble diameter up to 4m Only when an additional short circuit protection device is already installed can the battery be operated without a fuse Otherwise must a fuse be connected to the battery terminal pole in order to prevent possible short circuit of the battery cables Both components must be installed close together in the same room 2 Connect the solar module to the corresponding terminals on the solar charger 3 Connect the load to the solar charger unit The connection diagrams are printed on the solar charger Battery fully loaded The LEDs indicate the charge level of the batteries the actual charging status of the solar cells and possible system faults Protection against deep discharge red LED When battery deep discharging occurs all loads are automatically switched off and the red LED lights When the battery is recharged the LED stops illuminating and the loads are re connected automatically Now the battery is ready to supply power again The Solar System fails to function possible reasons Battery terminals are reverse connected The fuse has blown replace with a same type Module terminals are reverse connected Avoid at all costs Load terminals are reverse connected The equipment can be seriously damaged before the fuse blows Batteries contain considerable amounts of electrical energy A short circuit can result in a large build up of heat leading to FIRE
5. damage the batteries The amount of gas developed within the battery depends on the temperature The inbuilt temperature sensor automatically regulates the charging voltage in accordance with the temperature in the area of use operation The battery is not yet fully charged when the charging voltage is reached The charging current should not be completely switched off instead reduced so that the charging voltage is not exceeded This is accomplished by the Solar Charger Unit The charging process U charging recharges the batteries evenly and quickly The U charging is achieved by a very quick temporary short circuiting procedure also known as the pulse width modulation PWM shunt procedure Gas control function As a factory setting the regulator charges the battery with a 14 5V boost charge voltage When this voltage is reached the controller reduces it charging voltage to 13 7V float charge voltage which will be maintained until battery voltage sinks to 12 4V when the regulator start charging again with 14 5V Some sealed lead acid battery types require lower than 14 5V charging voltage as higher voltage would cause undesirable gas formation within the battery Please consult with your battery manufacturer about the max battery charging voltage if unsure In case you should reduce the max charging voltage you have the possibility to activate the built in gas control function see gas control activation section By doing so the
6. n reverse order see installation procedures Description of operation Solar Charge Controller Unit 12 24V_ 20A with 12 24 V automatic battery selection Dynamic protection against battery deep discharging Protection against battery overcharging Gas control function for sensitive SLA batteries Temperature compensation The use of lead batteries is common for the storage of solar energy photovoltaic solar systems Lead batteries require protection against overcharging and deep discharging This unit satisfies both requirements 12 24 V automatic battery voltage selection The solar regulator can be used for 12V and 24V battery systems manual adjustment is not required the unit automatically detects battery voltage and adjust itself accordingly All system components PV modules batteries inverter DC loads must be selected for the same voltage 12 or 24V rating Protection against battery deep discharging Lead Batteries need to be protected against being deep discharged otherwise damage can occur to the battery cells The solar battery charger unit protects lead batteries from deep discharging by disconnecting the DC loads when the battery s voltage has decreased to a certain voltage level As soon as the batteries are recharged by the solar cells the load is automatically reconnected Protection against overcharging Exceeding the max charging voltage levels 14 5V or 14 1V would lead to the formation of gas which could
7. ompletely damaged Each individual system component must be fused Factory settings Upon delivery is the Solar Charger Unit installed as follows Gas control deactivated see gas control function Warning When charging certain types of sealed lead acid batteries make sure that gas control function is activated Please consult your battery dealer to establish your optimal charging voltage gas control activation 1 Remove the 2 screws on the Solar Charger Unit which keeps the top piece in place and carefully remove cover 1 Cut the J6 wire bridge situated on the printed circuit board The gas control function is now activated Installation Warning Make sure of the right polarity The solar charger unit should be placed in close proximity to the battery and be sufficiently protected against the weather Take care to place the battery in a well ventilated place To guarantee that the unit functions properly it must be connected to the solar generator the lead battery and the load Each part of the system solar generator lead battery DC load and solar charger unit should have the same nominal operating voltage 12 or 24V Please check each component before installation when in doubt contact a Specialist Take careful attention of the following installation instructions l Connect the battery to the corresponding terminals on the solar charger unit To prevent voltage losses in the cabling please use min 6 mm ca
Download Pdf Manuals
Related Search
Related Contents
Operating and maintenance manual for Mini Bubble King Royal 安全上のご注意 本品について Fongicide FULLBACK 125 SC Uponor Smatrix Base Operating instructions - Nilfisk-Alto / Wap Product Manual here Zotac ZT-70209-10P NVIDIA GeForce GTX 780 6GB graphics card Refrigerator control evaluation board Samsung SPF-105V User Manual Copyright © All rights reserved.