BlackBox extended Installation and Programming manual

image

Contents

1. 2005 2007 Sky Laboratories Ltd All rights reserved Contact MODULES STATUS CONFIGURE STORE UPGRADE QUIT Receiver connection e Status Disconnected Type D6600 Settings 9600 baud Databit 8 bit Parity None Stopbit 1 bit Last seen Sent packets 18 Received packets 0 Packets in the queue 35 2005 2007 Sky Laboratories Ltd All rights reserved Contact Name The name is given to that module at time of registration Modul ID The ID number of the module at BlackBOX 2005 2007 Sky Laboratories Ltd All rights reserved Contact Accunt ID The account ID as to be identified in your existing monitoring automation software Icon signs Check in and out Last connection or disconection date and time of the module Test signal Time and date of the last test signal Connection is OK with the automation software There is no or fault in connecting with the automation software Status Momentary state of the connection with the automation software Type Type of the communication protokol Settings The serial port communication settings Last test signal time The last test signal time of the automation software 9 oldal www skylaboratories com BlackBox extended Installation amp Programming Manual 3 5 Configure MODULES STATUS CONFIGURE STORE UPGRADE QUIT Configure Administration Language Password Network setup
2. BlackBox extended Installation amp Programming Manual BlackBox extended Installation and Programming manual Features Expand existing monitoring stations to encrypted TCPIP and GPRS reception Minimal investment to entry level TCPIP and GPRS monitoring Easy to Install no major training needs Easy to program by any Web browser No need to extra desktop computer and does not include moving parts such as HDD or fans WEB firmware upgradeable Small size Low current consumption 500 clients per Blackbox for GPRS and TCPIP One fix IP address needed to operate Full continous 24 7 connection to modules and control panels of customers 128 bit high security encryption Real time synchronized clock Serial RS232 communication to monitorin automation softwares D6600 D6500 Surgard Ademco 685 serial protocol Heartbeat test signal watch at desired interval Status review per connected module control panel 25000 event log if not connected to automation software BlackBox extended Installation amp Programming Manual 1 0 General description 1 1 Front panel 1 1 1 Power up Push the power button on the front of the unit Power buton has a blue backlite Note All other outputs and connectors are not to be used 3 Specification Power supply Max Current consumption Size LxWxH 92 x 200 x 235mm Power Connector 3 5mm Ethernet Connector RJ45 RS 232 Connector Standard 9 pin Ethernet communi
3. 2007 Sky Laboratories Ltd All rights reserved Contact Note Firmware change BlackBox does not support any communication or between modules neither to automation software Uploading may take a few minutes 11 oldal www skylaboratories com BlackBox extended Installation amp Programming Manual 3 7 3 Update flow display After Upload command you may see the following MODULES STATUS CONFIGURE STORE UPGRADE QUIT Upgrade in progess Current firmware version BlackBox 1 04 build 200707041012 Upgrading to version blackbox ver 1 04 Status Upgrading application layer Base layer es 100745 Application layer i _ 23 Completed 54 Estimated time 01 16 16 31 kbit s 2005 2007 Sky Laboratories Ltd All rights reserved Contact Warning Dont close window and do not disconnect during upload 3 7 4 Finishing firmware update MODULES STATUS CONFIGURE STORE UPGRADE QUIT Upgrade in progess Current firmware version BlackBox 1 04 build 200707041012 Upgrading to version blackbox ver 1 04 Status Base layer Application layer Completed Estimated time 2005 2007 Sky Laboratories Ltd All rights reserved Contact After successfull firmware update you may see Successful firmware update and restart Warning System will automatically restart in 15 second 12 oldal 3 8 Reboot By clicking this button
4. IP address 192 168 4 197 255 255 255 0 192 168 4 16 192 168 4 16 Acknowledge character 2005 2007 Sky Laboratories Ltd All rights reserved Contact 3 5 1 Admin Language Select your language hereby Blackbox supports multi lingual settings Password To change administrator password Max 32 character Warning After changing password you need to Store new password or the previous password will be used further on with no change If you loose your password only factory can re set password and re setting password meaning complete restore of factory default values All admin programmed datas will be lost You may miss your password 2 times only 3rd wrong password will result disable the programming entry function You need to disconnect and connect power again to Blackbox Disconnecting the power will erease event memory 3 9 2 Network settings IP address Fix lp address given by the Internet or Network service provider or pre set fix ip address in the router Network mask Enter network mask provided by your IT personnels Gateway This is the IP address of the unit which connected to TCPIP networks and routing TCPIP communication Domain Name Server This is the ISP Domain name server Yould enter the IP address of the name server into this field Router could also be a name Server 10 oldal 3 5 3 Serial Port settings Speed or Baudrate Set speed according
5. suggest to set BB test signal interval to 20 or even 30 seconds to overlap more test signals and wait for reconnected open socket in order to create less communication failure reports Warning Use this function only if you are sure that communication distruption and reconnection will not cause extensive overbilling in the GPRS usage Note If you use GIO2 or SPG 804 panel leave this field open with 0 8 oldal www skylaboratories com BlackBox extended Installation amp Programming Manual 3 4 2 Connection 3 4 Status Temporary status display MODULES STATUS CONFIGURE STORE UPGRADE QUIT Note There is no on line periodical refreshing therefore you Receiver connection need to refresh this frame manually by pressing F5 key or browser refres Icon Status Connected Type D6600 Settings 9600 baud Databit 8 bit Parity None Stopbit 1 bit Last seen Sent packets 18 Received packets 0 Packets in the queue 35 3 4 1 Modul status MODULES STATUS CONFIGURE STORE UPGRADE QUIT Status Name Module ID Account ID Log in out Last seen Sky Laboratories Ltd 65535 FFFF 2007 03 28 18 07 22 2007 03 28 18 12 15 Alarmsensor 32131 0200 2007 03 28 11 06 24 2007 03 28 18 12 22 City Hall 102 0334 2007 03 28 18 07 23 2007 03 28 18 12 15 tobacco shop 103 0335 z Kindergarten 104 0336 Car shop 105 0337 2007 03 28 18 07 23 2007 03 28 18 12 15 Modules Receiver status
6. to your monitoring automation software Data bit Set it according to your monitoring automation software Parity Set it according to your monitoring automation software Stopbit Set it according to your monitoring automation software 3 5 4 Receiver settings Type of receiver Emulation of most popular receiver could be set here These formats will be communicated to the security monitoring automation software Heartbeat Between the BlackBox and the monitoring station there are constant heartbeat on the serial port You may set the timin here If heartbeat is missing Blackbox will display fault by blinking yellow LED End of line and acknowledge character Set it according to your monitoring automation software Hexa characters www skylaboratories com BlackBox extended Installation amp Programming Manual 3 6 Store 3 7 Firmware updates In constant development and for new functions manufacturer may provide new functions To download and activate these functions you do not need to dismantle Store Blackbox but could be easy downloaded from a A modulok param tereinek megv ltoztat s n l vagy be ll t sok m dos t skor On nem a t rolt konfigur ci t m dos tja hanem a rendszer csak tmenetileg t rolja azokat Ahhoz hogy On a be ll t sokat alkalmazza k rj k kattintson a T ro gombra Ame tols t rol s ta t rt nt fi fi FT RRL A SET Aa Seen pore mes s
7. you may choose two option Reboot The system will shut down and restart automatically All non volatile memory content will be lost Shudown The system will shut down All non volatile memory content will be lost MODULOK STATUSZ BEALLITASOK TAROLAS FRISSITES JRAIND T S Ujrainditas Biztos benne 2005 2007 Sky Laboratories Kft Minden jog fenntartva Kapcsolat The options will work only if you checkmark the box above www skylaboratories com BlackBox extended Installation amp Programming Manual Availability y Sky Laboratories Kft C m 2146 Mogyor d Pf 16 Kerekt u 2 Tel 36 28 542 250 Fax 36 28 542 251 Email sales skylaboratories com www skylaboratories com 13 oldal
8. cation 128bit AES encrypted Serial communication D6600 D6500 1 2 Blackplate All other outputs and connectors are not to be used 1 2 1 RS232 connector To be connected to the monitoring automation software Programming is detailed below in this manual 1 2 2 RJ45 Ethernet connector To connect with LAN WAN network One fix IP address required to operate the unit 1 2 3 DC12V Power supply connector Use Power supply only supplied with the unit Note All other outputs and connectors are not to be used Factory default IP address Factory default User name Factory default password Max nr of clients Test signal interval Event log Surgard Ademco 685 expandable 192 168 254 254 8080 Admin admin 500 from 10 sec 25000 BlackBox extended Installation amp Programming Manual 2 0 System setup service PC SPG TEE for Blackbox and SPG Centralstation Router Backup BlackBox E munication 7 g FSTH receiver 4 oldal www skylaboratories com BlackBox extended Installation amp Programming Manual 2 1 1 Application The unit is designed to keep direct constant connection and logging with Ethernet and GPRS TCP IP communication devices and transfer encrypted communication to serial RS232 port communication in order to connect it to most usual monotiring softwares 2 1 2 Minimum HW and SW requirements 1 The automation software must have on
9. designated site MODULES STATUS CONFIGURE STORE UPGRADE QUIT Stored config cheksum 0aa2a89f2dd695cafb118d3a06eb35a2 Temporary config cheksum Oaa2a89f2dd695cafb118d3a06eb35a2 No need to store store Restore MODULES STATUS CONFIGURE STORE UPGRADE QUIT Upgrade Current version BlackBox 1 04 build 200707041012 A k sz l k rendszerprogramjanak frissit s vel a modul m k d se stabilabb tehet vagy az jabb fejleszt s funkci k aktivalhatdk A modul kialak t sa a folyamatos zemeltet se rdek ben gy t rt nt hogy a modult ne kelljen cser lni vagy visszajuttatni a gy rt hoz csak a gy ri friss t f ljt kell a modulra felt lteni Figyelmeztet s A friss t f jl felt lt se alatt a modul t pfesz lts g nek kommunik ci s kapcsolat nak 100 osan stabilnak kell lennie Amennyiben friss t s k zben hiba l p fel a modulon v gzetes hiba l phet fel melyet csak a gy rt k pes helyre ll tani Firmware file 2005 2007 Sky Laboratories Ltd All rights reserved Contact By changing the parameters you temporarily save them into a memory If the parameters are correct you need to STORE those values in order to activate them To re cover previous settions you may do so with the restore button 2005 2007 Sky Laboratories Ltd All rights reserved Contact Note On each page you need to save the setting by Save and Enter puttons Than the program will display a
10. e free RS232 port 2 The automation software should be able to handle standard Contact ID communication 3 Install the router behind firewall or router 4 Need of one free fix public IP address Note The BlackBox programming computer must have connection to the same network and have an Internet browser installed For further BB upgrade could be done by Internet connection if necessary 5 oldal Warning Blackbox is able to log 25000 event until power is applied Mains voltage supplying BlackBox must be an uninterruptable power supply 1 1 Installation 1 Connect router to the socket provided by your Internet service provider 2 Program router according to the installation manual 3 Program BlackBox according to the installation manual 4 Connect router to the Blackbox 5 Connect the serial port of the BlackBox to the monitoring station software with standard RS232 serial cable Apply power router Apply power on BlackBox Enable RS232 port receiving on your automation software and adjust serial port setting according to your software installation manual 9 Test system that BlackBox from sending communication from existing control panel or through Sky Laboratories compatible modems and devices a a www skylaboratories com BlackBox extended Installation amp Programming Manual 3 0 BlackBox Programming 3 2 General description 3 1 Enter i
11. ecutive times the unit disables programming entry until hardware reset Hardware reset could be performed by removing power and applying it again This will erase event log but not erease BlackBox program settings This is a feature to provide higher security agaings hackers 6 oldal www skylaboratories com E BlackBox extended Installation amp Programming Manual 3 3 Modules Modules are the pre installed units which are communicating with BlackBox 3 3 1 Active Modules Selecting Moduls will direct you to Active Modules sub menu The pre programmed modules could be seen in this window FE0200000023FF35 FE0200000000012D FE02000000000FD1 FEO2000000000EE1 FEO200000000BEF7 FE02000000008357 2005 2007 Sky Laboratories Ltd All rights reserved Contact Window description Name Could be any end user account specific description Serial Number The modul hardware ID which is a unique serial ID number on each module Its show non a printed label on the pcb of the module Modul ID Module ID Accunt ID The customer Contact ID as required by the automation software you currently use Dispatcher ID This is a fix not changeable number Fix nem valtoztathato K Deleting a Module If you would like to delete one module from the connections in order not to monitor further click the icon you will be asked again to verify if you reall
12. ew module Module name Serial 2 Module ID J Use Account ID ooo Temporarily you can disable communication between pa the BlackBox and the Module this way is to ignore active certain modules o 5 o ol Example maintenance of the system of the customer or for unpaid accounts 3 3 4 Change modul settings 2005 2007 Sky Laboratories Ltd All rights reserved Contact Window description Modul name Could be any customer specific max 32 character Click on the name of the module wither on Status or long Modul page Y ill i h f th le Serial Nr ou will ba directed to the setup page of the module Labelled on the module 16 digit HEX character sequence ii Dispatcher ID i Wag Edit dule SPG Ady 11 Factory set all modul must have same Dispatcher ID Woddenane SBGAGy Test Signal Interval 10sec m a To ignore test signal failure within the duration Active a programmed in this section For open socket communication distruption Thes signal interval is not determined by the BlackBox but the user module The test signal interval is to be used to overlap a few test intervals set in the user modules 2005 2007 Sky Laboratories Ltd All rights reserved Contact Example If the test signal interval in the end user modules is set for 10 second but the network quality is low it may happen that it will be not processed within 10 second We
13. nto programming mode 1 Open Internet browser EG Internet Explorer Mozzilla etc 2 Type first the factory IP address setting into browser address field http 192 168 254 254 8080 Warning If this address exist in your network you should either re program any of the two unit first or remove BlackBox from 1 Main menu the network and program by cross cable direct from the 2 Sub menu computer 3 The subscribtion of the selected menu Note Main menu Sub menu The panel will be reacheable through two IP addresses so the factory IP address will allways remain in BlackBox setting as one of the connection IP address Active modules 3 Successful contact will provide you the window for Inactive modules User name and Password fields Modules Csatlakoz s 192 168 4 244 OB New module AE ah BlackBox Sky Laboratories Ltd Setup Utility Modules Status Felhaszn l n v Receiver Status Jelsz L I Jelsz megjegyz se Configure store Set the User name Set the password Upgrade Note Factory pre set User name Admin Password admin Make sure you have capslock off since its case sensitive Reboot Reboot Shutdown Warning lf you click your browser to remember password and someone else is using that computer you might have unauthorized person to re program the BlackBox Therefor we suggest DO Not accept Password save If you miss password 3 cons
14. warning icon ont he bottom of the screen to store these settings Warning During Firmware update power and communication must be 100 secured otherwise not recovereable damage may occure CO Configuration has changed don t forget to store it 3 7 1 Selecting Firmware Update By browsing you may select the required firmare 3 7 2 Upload Warning You start to upload the firmware file by hitting Upload If you do not use save enter on each page than previous button values will be used as new setting after hitting STORE MODULES STATUS CONFIGURE STORE UPGRADE QUIT Upgrade Current version BlackBox 1 04 build 200707041012 A k sz l k rendszerprogramjanak frissit s vel a modul m k d se stabilabb tehet vagy az jabb fejleszt s funkci k aktivalhatdk A modul kialak t sa a folyamatos zemeltet se rdek ben gy t rt nt hogy a modult ne kelljen cser lni vagy visszajuttatni a gy rt hoz csak a gy ri friss t f ljt kell a modulra felt lteni Figyelmeztet s A friss t f jl felt lt se alatt a modul t pfesz lts g nek kommunik ci s kapcsolat nak 100 osan stabilnak kell lennie Amennyiben friss t s k zben hiba l p fel a modulon v gzetes hiba l phet fel melyet csak a gy rt k pes helyre ll tani Firmware file Uploaded file Firmware blackbox ver 1 04 Device Skylab BlackBox Base layer Checked OK Application layer Checked OK Upgrade 2005
15. y want to delete Note If you go to Edit Modules point you may dis activate modules without deleting it 7 oldal 3 3 2 Inactve modules Registered but communication ignored modules As shown in section 3 3 3 MODULES STATUS CONFIGURE STORE UPGRADE QUIT Active modules Inactive modules New module Module ID Accoun 2005 2007 Sky Laboratories Ltd All rights reserved Contact Window description Name The name is given to that module at time of registration Serial number The hardware ID of the modul There are no two same hardware ID in the World by factory setting Label with the number is to be found ont he pcb Modul ID The ID number of the module at BlackBOX Accunt ID The account ID as to be identified in your existing monitoring automation software Dispatcher ID Dispatcher ID Fix not changeable Note If you would like to delete one module from the connections in order not to monitor further click the icon you will be asked again to verify if you really want to Automata 3 F mipari v llalat Igazgat s g H mori rp d Ady Endre u 11 www skylaboratories com BlackBox extended Installation amp Programming Manual 3 3 3 Setting up a new modul Activ To show whether the module is active or inactive Inactive modules are not communicating with the i a a T RESOUN BlackBox Sam Inactive modules are listed on Inactive modules window N

Download Pdf Manuals

image

Related Search

Related Contents

D6.3 Evaluation Guidelines for Developing POPEYE Applications  Install Sheet - Xtreme Diesel Performance  Cucitura laterale e piegatura  PYLE Audio PIFM2 User's Manual  PAR 64 FLOOR  Guida all`installazione  2 ton tripod under hoist stand owners manual specifications kti61002  Matériels et ingrédients Mode d`emploi  RAPPORT COMPLET  