Home
FX3U-ENET-L INSTALLATION MANUAL
Contents
1. The version number can be checked by reading the last three digits of device D8001 An FX2NC CNV IF or FX3UC 1PS 5V is necessary to connect the FX3U ENET L with the FX3UC PLC 3 2 Related software Model name Applicability FX Configurator EN L Ver 1 00 and later GX Developer Ver 8 88S and later 1 To use FX Configurator EN L either of the following software should be installed GX Developer Ver 8 88S or later 1 Direct mounting hole 2 holes of 64 5mm 0 18 Used when FX3U ENET L is directly mounted Not used when DIN rail is mounted 2 DIN rail mounting groove 3 DIN rail mounting hook 4 Extension cable 5 RUN LED 6 INIT LED 7 100M LED 8 SD LED 9 RD LED 10 ERR LED 11 COM ERR LED 12 POWER LED 13 C1 to C4 LEDs 14 1OBASE T 100BASE TX connector RJ45 15 External 24VDC terminal M3 terminal block screw 16 Extension connector Indications of LEDs LED Indication O Off On o RUN Normal operation 7 O Abnormal operation F INIT Initial processing normal completion Initial processing not performed 0 100M 100Mbps O 10Mbps When not connected SD Data being sent O Data not being sent RD Data being received Data not being received ERR Abnormal setting display O Normal setting display COM ERR Abnormal communication display O Normal communication display POWER Power on O Power off C1toC4 TCP IP Conne
2. The diagnostic functions of FX Configurator EN L enables easy diagnostics and side of sending data Manual name ManualNo Description troubleshooting of the FX3U ENET L Type Programmable Controller Open Type Equipment i POO f side of sending data FX3U ENET L Models MELSEC FX3U series manufactured 1 It is necessary to set up the open system by configuring open settings in INSTALLATION JY997D37801 This manual advance pL side of receiving data MANUAL from October 1st 2009 FX3U ENET L 1 1 Incorporated Items 3 1 cr Describes the specifications Standard Remark FX3U ENET L e wiring installation maintenance EN61131 2 2007 c z T Eeri Included Item Notused User s Manual Jand operations of the FX3u Ei OmMmpYance Wira aT Erevan aASPECIS OURS In side of receiving data i 09R722 ned a Programmable controllers standard FX3U ENET L 1 unit RD n 9 j i gt Pupan pedurenan EN Label for indication of special function unit block number 1 sheet Notused EX3u Series Briefly describes the I O and tests e Radiated Emissions p 2 Notusedf HARDWARE JY997D18801 specifications wiring and Conducted Emissions Dust proof protection sheet 1 sheet installation of the FX3U Series EMS Cables to be used MANUAL p 5 i PLC e Radiated electromagnetic field Installation Manual Japanese version English version 1 manual each 7 j Category 5e shielded twisted pair cable FX3U Series
3. consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN JY997D37801B Fs APANESE S E ENGLISH a MITSUBISHI PROGRAMMABLE CONTROLLERS MELSEC F Side B Changes for the Better FX3U ENET L INSTALLATION MANUAL Manual Number JY997D37801 wen fe This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company and product name described in this manual are registered trademarks or the trademarks of their respective companies Effective June 2010 Specifications are subject to change without notice 2009 Mitsubishi Electric Corporation F X 3u Safety Precaution Read these precautions before use This manual classifies the safety precautions
4. General specifi Dielectric withstand cation voltage Full duplex Half duplex Trans method MISSION Transmission method Base band specifi cations Maximum segment 1A au length 100m 328 1 Maximum number of Cascade connection Cascade connection nodes connection Maximum 2 stages Maximum 4 stages Fixed buffer Number of communica 2 connections simultaneously tion open connections mELSOFT allowed connection A total of 2 connections MC protocol Trans Fixed buffer 1023 word x 2 nee Attached fil 2048 dx 1 ached file wor data Emai Atached fle storage 9 3 Number of I O occupied points 8 points 24V DC 240mA 24V DC 20 15 external power supply ripple p p less than 5 Allowable Instanta Operation can be continued upon occurrence of Power i S ppl neous power instantaneous power failure for 1 ms or less pp y failure time specifi cations 5V DC of PLC is not used 5V DC is converted from 24V DC external power supply Make sure to observe the power on timing and the procedure 5V DC internal power supply 90 H x 55 W x 87 D mm Exoimal dimensions 3 55 H x 2 17 W x 3 43 D inches MASS Weight 0 3kg 0 66lbs Number of connectable units to the main unit 1 Length between a hub and a node 2 Refer to the FX3U ENET L User s Manual of e mail sending function specifications 3 It is not possible to send an attached file and main text simultaneous
5. JY997D16501 Explains the FX3U Series PLC Fast Transient burst User s Manual MODEL CODE specifications for I O wiring Electrostatic discharge hee Penna e Sete And Pari Names ee iN Hiap a eta Hardware Edition 09R516 installation and maintenance High energy surge 2 4 5 mounting holes 15 Jy p e Voltage drops and interruptions 3 FX3G FX3U FX3UC lt Conducted RE A For 100BASE TX Category 5e shielded twisted pair cable Series JY997D16601 Describes PLC programming for Power frequency magnetic field 1 Category 5 shielded twisted pair cable Programming Manual MODEL CODE basic applied instructions and s Basic amp Applied 09R517 devices io Instruction Edition Caution for EC Directive a 2 Installation r Installation in Enclosure S FX3uc D DSS Briefly describes the I O 0 INSTALLATION Series specifications wiring and Programmable logic controllers are open type devices that must be installed PRECAUTIONS lt SDANGER JY997D28601 and used within conductive control cabinets Please use the programmable HARDWARE installation of the FX3UC Series i SR ae i i MANUAL PLC logic controller while installed within a conductive shielded control cabinet 3 e Make sure to cut off all phases of the power supply externally before Please secure the cabinet door to the control cabinet for conduction TT 9 0 36 4 0 16 attempting installation work FX3UC 32MT LT 2 B He A bes th e 4 Installation within a control
6. Mitsubishi product provider refer to following figure COM ERR Abnormal een display Regarding the standards that comply with the main unit please refer to either the FX Exceeding 30m O Normal communication display i series product catalog or consult with your nearest Mitsubishi product provider EX3U ENET L g POWER Power on Safety Precaution Read these precautions before use f f eau 3U L 2500mm or less NoiSe 24V DC power l 2 ma Aa Requirement for Compliance with EMC directive 24V DC e F supply Power off A Mandat Classilics Hic salely precautions inioiworcalegones The following products have shown compliance through direct testing of the identified C1toC4 TCP IP Connection established DANGER and A CAUTION standards below and design analysis through the creation of a technical construction UDP Open file to the European Directive for Electromagnetic Compatibility 2004 108 EC when 4 d as directed by th iate d tati Outline O TCP IP Connection not established DANGER ANGER dicates that incorrect handling may cause hazardous men yee FX3U ENET L is an Ethernet unit for the FX3U FX3UC Series PLC that is compliant with UDP Closed conditions resulting in death or severe injury Attention 400BASE TX 10BASE T and has the features as follows eens EE E E ees e This product is designed for use in industrial applications thi i ndicaies hat neonect hendina tmay cauce hazardous 1 Data and programs within
7. WNW Aena When connecting to an FX3uc When connecting the FX3U ENET L either the FX3UC 1PS 5V or FX2NC CNV IF is required Connector cover FX3uUC 1PS 5V 1 The connector cover A of the FX3UC 1PS 5V is removed as shown in the figure to the right The FX2NC CNV IF does not have a connector cover 2 Connect the extension cable as shown to the right _ FX3UC 1PS 5V or FX2NC CNV IF 3 Specification For details on specifications refer to the following manual Refer to the FX3U ENET L User s Manual DESIGN PRECAUTIONS DANGER e Make sure to include the following safety circuits outside the PLC to ensure safe system operation even during external power supply problems or PLC failure Otherwise malfunctions may cause serious accidents 1 Most importantly have the following an emergency stop circuit a protection circuit an interlock circuit for opposite movements such as normal vs reverse rotation and an interlock circuit to prevent damage to the equipment at the upper and lower positioning limits 2 Note that when the PLC main unit detects an error such as a watchdog timer error during self diagnosis all outputs are turned off Also when an error that cannot be detected by the PLC main unit occurs in an input output control block output control may be disabled External circuits and mechanisms should be designed to ensure safe machinery operation in such cases DESIGN PRECAUTIONS CA
8. cabinet greatly affects the safety of the system and T a78 43 55 2 17 Ly is Failure to do so may cause electric shock or damage to the product HARDWARE JY997D31601 ee ee aids in shielding noise from the programmable logic controller e Before attaching or replacing the main unit or extension unit externally cut MANUAL installation of the FX3UC 32MT ff all ph fth ly Fail iad functi LT 2 PLC Unit mm inches off all phases of the power supply Failure to do so may cause malfunctions or misoperations MASS Weigth 0 3kg 0 66Ibs DIN rail width 35mm 1 38 INSTALLATION PRECAUTIONS CAUTION Use this product within the generic environment specifications described in this manual Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions fire malfunctions deterioration or damage may occur When tightening the terminal screws stay within the specified torque range When tightened insufficiently short circuit or failure may occur When tightened too much the screws or the unit may be damaged causing the unit disposal short circuit or failure Do not touch the conductive part or electric parts of this unit directly Doing so may cause failure or malfunctions Install the unit on a flat surface If the mounting su
9. for I O wiring installation and maintenance JY997D38401 MODEL CODE 09R929 FX Configurator EN L operation Manual Describes the operation method of FX Configurator EN L Only this INSTALLATION MANUAL is supplied with the FX3U ENET L For more details regarding the FX3U FX3UC Series hardware PLC programming commands and special function blocks units refer to the appropriate manuals How to obtain manuals For product manuals or documents consult with the Mitsubishi Electric dealer from who you purchased your product How to obtain FX Configurator EN L The parameter setting software FX Configurator EN L is not supplied with this product Consult with the Mitsubishi Electric dealer from who you purchased this product Certification of UL cUL standards FX3U ENET L units comply with the UL standards UL cUL UL cUL File Number E95239 Regarding the standards that comply with the main unit please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive and LVD directive for the entire mechanical module should be checked by the user manufacturer For more information please consult with your nearest Mitsubishi product provider Regarding the sta
10. into two categories DANGER and CAUTION Indicates that incorrect handling may cause hazardous lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on the circumstances procedures indicated by A CAUTION may also cause severe injury It is important to follow all precautions for personal safety Associated Manuals Manual name ManualNo Description FX3U ENET L INSTALLATION JY997D37801 This manual MANUAL Describes the specifications FX3U ENET L AT Donon wiring installation maintenance MODEL CODE User s Manual 09R722 and operations of the FX3U ENET L FX3U Series eo aon aes HARDWARE JY997D18801 SP i g a installation of the FX3U Series MANUAL PLC FX3U Series JY997D16501 Explains the FX3U Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R516 installation and maintenance FX3G FX3U FX3UC Series JY997D16601 Describes PLC programming for MODEL CODE 09R517 HARDWARE Briefly describes the I O specifications wiring and wie O 2860 installation of the FX3UC Series MANUAL PLC Fxoue 32MTAT 2 A eae Sy eine ene te installation of the FX3UC 32MT LT 2 PLC INSTALLATION PRECAUTIONS Programming Manual Basic amp Applied Instruction Edition FX3UC D DSS Series basic applied instru
11. B JY997D37801B_ B E sAPANESE ENGLISH e Control cabinet Manual name Description e aia ig di 1 Direct mounting hole 2 holes of 4 5mm 0 18 3 contro cabinet must be conductive Used when FX3U ENET L is directly mounted ate MITSUBISHI Changes for the Better FX3UC Series JYP DAOTO Explains ite eae Sales PEG Ground the control cabinet with the thickest possible grounding cable Not used when DIN rail is mounted USTE Mannal MOPPE ODE epee me aNeds Aar Mao wing To ensure that there is electric contact between the control cabinet and its door 2 DIN rail mounting groove 3 DIN rail mounting hook PROGRAMMABLE CONTROLLERS Hardware Edition 09R519 installation and maintenance onrecdiie cbinetand il dc Wir KATE a Fel cable a OND Walle SleGelr FX Configurator EN L ee ore Describes the operation method of In order to suppress the leakage of radio waves the control cabinet structure 8 SD LED 9 RD LED FX3U EN ET L operation Manual 09R929 FX Configurator EN L must have minimal openings Also wrap the cable holes with a shielding cover 10 ERR LED 11 COM ERR LED or other shielding devices 12 POWER LED 13 C1 to C4 LEDs Only this INSTALLATION MANUAL is supplied with the FX3U ENET L The gap between the control cabinet and its door must be as small as possible 14 10BASE T 100BASE TX connector RJ45 N STAL LAT O N MAN UAL For more details regarding the FX3U FX3UC Series hardware PLC programming by attachi
12. UTION e Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise 1 Do not bundle the main circuit line together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likey to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit or high voltage lines 2 Ground the shield wire or shield of a shielded cable However do not ground them at the same point as the high voltage lines e Install module so that excessive force will not be applied to the unit or cables Failure to do so may result in wire damage breakage or PLC failure STARTUP AND MAINTENANCE PRECAUTIONS DANGER Do not touch any terminals or connector while the PLC s power is on Doing so may cause electrical shock or malfunctions Before cleaning or retightening screws externally cut off all phases of the power supply Failure to do so may cause malfunction or failure of this unit When the screws are tightened insufficiently they may fall out and cause a short circuit or malfunction When tightened too much the screws or the unit may be damaged resulting in short circuit or malfunction When controlling the PLC especially when changing data the program or changing the operating conditions during operation ensure that
13. abinet and its door must be as small as possible by attaching EMI gaskets between them Shielding cover Shielded cable Wires EMI gasket These wires are used to improve the conductivity between the door and control cabinet e Notes for compliance with EN61131 2 2007 General notes on the use of the power supply cable The FX3U ENET L unit requires that the cable used for power supply is 30m or less When the cable used for power supply exceeds 30m a noise filter Ex TDK Lambda MBS1205 22 or similar should be placed on the 24V DC power cabling as close within 500mm to the FX3U ENET L termination points as possible refer to following figure Exceeding 30m 500mm or less FX3U ENET L NoiSe 24V DC power SA zay o e i sl 1 Outline FX3U ENET L is an Ethernet unit for the FX3U FX3UC Series PLC that is compliant with 100BASE TX 10BASE T and has the features as follows 1 Data and programs within the PLC can be sent and received via Ethernet by using GX Developer Ver 8 88S or later 2 Communication between PLCs or with a general Ethernet device is possible by fixed buffer communication TCP IP or UDP IP 3 Users can develop custom software to communicate with the PLC by using MC MELSEC Communication protocol A compatible 1E frame subset for details refer to user s manual TCP IP or UDP IP 4 E mail can be sent SMTP protocol 5 The FX3U ENET L parameters can be set easily using FX Configu
14. ction established UDP Open O TCP IP Connection not established UDP Closed The ERR LED illuminates in the following cases When a parameter setting error occurs in the Ethernet unit When an operational error occurs in the PLC CPU When an error is found in the Ethernet unit H W error Pin Configuration The pin configuration of FX3U ENET L RJ45 type modular jack for category 5 or category 3 is as follows Contents side of sending data side of sending data ptititii side of receiving data CE RD n side of receiving data Porsa C Cables to be used Category 5e shielded twisted pair cable Category 5 shielded twisted pair cable Category 3 shielded twisted pair cable For 10BASE T Category 5e shielded twisted pair cable FOP TOUBASE TA Category 5 shielded twisted pair cable 2 Installation INSTALLATION PRECAUTIONS DANGER e Make sure to cut off all phases of the power supply externally before attempting installation work Failure to do so may cause electric shock or damage to the product e Before attaching or replacing the main unit or extension unit externally cut off all phases of the power supply Failure to do so may cause malfunctions or misoperations 4 Wiring WIRING PRECAUTIONS DANGER e Make sure to cut off all phases of the power supply externally before attempting wiring work Failure to do so may cause electric shock or damage to the pro
15. ctions and devices CAUTION e Use this product within the generic environment specifications described in this manual Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions fire malfunctions deterioration or damage may occur When tightening the terminal screws stay within the specified torque range When tightened insufficiently short circuit or failure may occur When tightened too much the screws or the unit may be damaged causing the unit disposal short circuit or failure Do not touch the conductive part or electric parts of this unit directly Doing so may cause failure or malfunctions Install the unit on a flat surface If the mounting surface is rough undue force will be applied to the PC board thereby causing nonconformities Install the product securely using a DIN rail or mounting screws When drilling screw holes or wiring make sure that cutting or wire debris dose not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Be sure to remove the dust proof sheet from the PLC s ventilation port when installation work is completed Failure to do so may cause fire equipment failures or malfunctions Connect extension cables securely to their designated con
16. data the program or changing the operating conditions during operation ensure that it is safe to do SO STARTUP AND MAINTENANCE PRECAUTIONS CAUTION Do not disassemble or modify the unit Doing so may cause fire equipment failures or malfunctions The unit case is made of resin If dropped or subjected to strong impact the unit may be damaged When this unit is installed or removed from the panel make sure to externally cut off all phases of the power supply Failure to do so may cause malfunction or failure of this unit DISPOSAL PRECAUTIONS CAUTION e Please contact a certified electronic waste disposal environmentally safe recycling and disposal of your device company for the TRANSPORT AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the operations of the product A e Control cabinet The control cabinet must be conductive Ground the control cabinet with the thickest possible grounding cable To ensure that there is electric contact between the control cabinet and its door connect the cabinet and its doors with thick wires In order to suppress the leakage of radio waves the control cabinet structure must have minimal openings Also wrap the cable holes with a shielding cover or other shielding devices The gap between the control c
17. duct WIRING PRECAUTIONS CAUTION e Before wiring the unit confirm that the rated voltage and terminal allocation of the unit are correct An incorrect voltage supply and or incorrect wiring may cause fire malfunction or failure Perform class D grounding grounding resistance 100Q or less to the grounding terminal on the main unit Do not use common grounding with heavy electrical systems Prevent cutting or wiring debris from entering the main unit Failure to do so cause fire malfunctions or failures Place a label that warns of electrical shock 417 IEC 5036 on the enclosure of the final equipment 4 1 Grounding Other equipment Independent grounding Best condition Other equipment Common grounding Not allowed Shared grounding Good condition Wiring and power supply wiring between PLC and FX3U ENET L Example usage of FX3U Externally power supply for FX3U ENET L 24V DC D Grounding 100 Q or less Ethernet modular jack _ RJ 45 HUB This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost pro
18. fits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system sa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN
19. ions aa cabinet D Data bei t Store this manual in a safe place so that it can be taken out and read whenever dps ede ean aa la fas pre bd elliot a tieas ieee to o Hema e Notes for compliance with EN61131 2 2007 S Data being necessary Always forward it to the end user SEUES a 9 SUM WIEN YOUR NEALEST a PIOVCEN General notes on the use of the power supply cable O Data not being sent Registration Compliance with EC directive CE Marking The FX3U ENET L unit requires that the cable used for power supply is 30m or RD Data being received The company and product name described in this manual are registered less Data not being received trademarks or the trademarks of their respective companies This note does not guarantee that an entire mechanical module produced in a g aA a a A accordance with the contents of this note will comply with the following standards When the cable used for power supply exceeds 30m a noise filter Ex TDK ERR Abnormal setting display Effective June 2010 Compliance to EMC directive and LVD directive for the entire mechanical module Lambda MBS1205 22 or similar should be placed on the 24V DC power cabling O Normal setting display Specifications are subject to change without notice should be checked by the user manufacturer For more information please consult as close within 500mm to the FX3U ENET L termination points as possible re 2009 Mitsubishi Electric Corporation with your nearest
20. it is safe to do so STARTUP AND MAINTENANCE PRECAUTIONS A CAUTION Do not disassemble or modify the unit Doing so may cause fire equipment failures or malfunctions The unit case is made of resin If dropped or subjected to strong impact the unit may be damaged When this unit is installed or removed from the panel make sure to externally cut off all phases of the power supply Failure to do so may cause malfunction or failure of this unit DISPOSAL PRECAUTIONS CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device TRANSPORT AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the operations of the product Items other than the following are equivalent to those of the PLC main unit For general specifications refer to the manual of the PLC main unit Refer to the FX3U Series User s Manual Hardware Edition Refer to the FX3UC Series User s Manual Hardware Edition Item Specifications 0 to 55 C 32 to 131 F when operating and 20 to 75 C 4 to 167 F when stored 500 V AC for one minute Between all terminals and the Insulation resistance 5MQ or more by 500V DC ground terminal Data transmission 100Mbps 10Mbps speed Communication Ambient temperature
21. ly 3 1 Applicable PLC Model name Applicability Ver 2 21 and later Only one FX3U ENET L unit can be connected in a main unit FX3U Series PLC Ver 2 21 and later Only one FX3U ENET L unit can be connected in a main unit FX3UC Series PLC 1 The version number can be checked by reading the last three digits of device D8001 An FX2NC CNV IF or FX3UC 1PS 5V is necessary to connect the FX3U ENET L with the FX3UC PLC 3 2 Related software Model name Applicability FX Configurator EN L Ver 1 00 and later GX Developer Ver 8 88S and later To use FX Configurator EN L either of the following software should be installed GX Developer Ver 8 88S or later 4 Wiring WIRING PRECAUTIONS DANGER e Make sure to cut off all phases of the power supply externally before attempting wiring work Failure to do so may cause electric shock or damage to the product WIRING PRECAUTIONS CAUTION e Before wiring the unit confirm that the rated voltage and terminal allocation of the unit are correct An incorrect voltage supply and or incorrect wiring may cause fire malfunction or failure e Perform class D grounding grounding resistance 100Q or less to the grounding terminal on the main unit Do not use common grounding with heavy electrical systems e Prevent cutting or wiring debris from entering the main unit Failure to do so cause fire malfunctions or failures e Place a label that warn
22. ndards that comply with the main unit please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider Requirement for Compliance with EMC directive The following products have shown compliance through direct testing of the identified standards below and design analysis through the creation of a technical construction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by the appropriate documentation Attention e This product is designed for use in industrial applications Note e Manufactured by Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan e Manufactured at Mitsubishi Electric Corporation Himeji Works 840 Chiyoda machi Himeji Hyogo 670 8677 Japan e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Type Programmable Controller Open Type Equipment Models MELSEC FX3U series manufactured from October 1st 2009 FX3U ENET L Standard Remark EN61131 2 2007 Programmable controllers Equipment requirements and tests Compliance with all relevant aspects of the standard EMI e Radiated Emissions e Conducted Emissions EMS e Radiated electromagnetic field e Fast Transient burst e Electrostatic discharge e High energy surge e Voltage drops and interruptions e Conducted RF e Power frequency magnetic field Ca
23. nectors Loose connections may cause malfunctions 2 1 Mounting The FX3U ENET L can be mounted directly using screws or on a DIN rail DIN46227 2 1 1 Direct Mounting The FX3U ENET L can be mounted with M4 screws by using the direct mounting holes A space of 1 to 2 mm 0 04 to 0 08 between each unit is necessary 2 1 2 DIN Rail Mounting The FX3U ENET L can be mounted on a DIN rail DIN46227 35mm width 1 Fit the upper edge of the DIN rail mounting groove fig A onto the DIN rail 2 Push the unit onto the DIN rail 2 1 3 Procedure for connecting with the FX3u Series PLC When connecting to an FX3u Before connections turn off the power to the PLC lt 1 Remove the extension device connector cover of the main unit 2 Fold and insert the extension cable in the corresponding connector as shown to the right 3 Reattach the extension device connector cover on the main unit WNINNINA WW When connecting to an FX3uc When connecting the FX3U ENET L either the FX3UC 1PS 5V or FX2NC CNV IF is required 1 The connector cover A of the FX3UC 1PS 5V is removed as shown in the figure to the right The FX2NC CNV IF does not have a connector cover 2 Connect the extension cable as shown to the right K FX3uc 1PS 5V or FX2NC CNV IF Manual name Description JY997D28701 MODEL CODE 09R519 FX3UC Series User s Manual Hardware Edition Explains the FX3UC Series PLC specifications
24. ng EMI gaskets between them 1 extemal 24V DC temmingiiis temunal Bleck serew 16 Extension connector d ial function block it fer to th iat Is commands and special function blocks units refer to the appropriate manuals AE ieee Shen How to obtain manuals Manual Number JY997D37801 Revision JB o For product manuals or documents consult with the Mitsubishi Electric dealer from Shielding cover LED Indication O Off On who you purchased your product Shielded cable o RUN Normal operation l l J June 2010 How to obtain FX Configurator EN L 0 i SS H i Al t The parameter setting software FX Configurator EN L is not supplied with this product O j noria pia ji Sea PSO Consult with the Mitsubishi Electric dealer from who you purchased this product 9 INIT Initial processing normal completion This manual describes the part names dimensions mounting and k O Initial pr ina not performed specifications of the product Before use read this manual and the manuals of Certification of UL cUL standards oe EMI gasket Oo ssh ihc hae NOL oe all relevant products fully to acquire proficiency in handling and operating the FX3U ENET L units com y with the UL standards UL cUL Wires o O 100M 100Mbps product Make sure to learn all the product information safety information and UL cUL File Number aha i D are used to improve the conductivity between the door and control 10Mbps When not connected precaut
25. nnection Cascade connection nodes connection Maximum 2 stages Maximum 4 stages Fixed buffer Number of communica 2 connections simultaneously tion open connections allowed MELSOFT connection A total of 2 connections MC protocol Trans Fixed buffer 1023 word x 2 mission f data E mail Attached file 2048 word x 1 storage 2 3 Number of I O occupied points 8 points 24V DC external power supply 240mA 24V DC 20 15 ripple p p less than 5 Allowable Power Instanta Operation can be continued upon occurrence of supply neous power instantaneous power failure for 1 ms or less ip failure time specifi cations 5V DC of PLC is not used 5V DC is converted from 24V DC external power supply Make sure to observe the power on timing and the procedure 5V DC internal power supply 90 H x 55 W x 87 D mm 3 55 H x 2 17 W x 3 43 D inches 0 3kg 0 66lbs External dimensions MASS Weight Number of connectable units to the main unit 1 Length between a hub and a node 2 Refer to the FX3U ENET L User s Manual specifications of e mail sending function 3 It is not possible to send an attached file and main text simultaneously 3 1 Applicable PLC Model name Applicability Ver 2 21 and later Only one FX3U ENET L unit can be connected in a main unit FX3U Series PLC Ver 2 21 and later Only one FX3U ENET L unit can be connected in a main unit FX3UC Series PLC 1
26. rator EN L 6 The diagnostic functions of FX Configurator EN L enables easy diagnostics and troubleshooting of the FX3U ENET L 1 It is necessary to set up the open system by configuring open settings in advance 1 1 Incorporated Items Included Item FX3U ENET L 1 unit Label for indication of special function unit block number 1 sheet Dust proof protection sheet 1 sheet Installation Manual Japanese version English version 1 manual each 1 2 External Dimensions and Part Names 2 4 5 mounting holes 2 80 3 15 2 eT H 9 0 36 87 3 43 MASS Weigth 0 3kg 0 66lbs Top cover is 55 2 17 removed Unit mm inches DIN rail width 35mm 1 38 Items other than the following are equivalent to those of the PLC main unit For general specifications refer to the manual of the PLC main unit Refer to the FX3U Series User s Manual Hardware Edition Refer to the FX3UC Series User s Manual Hardware Edition Item Specifications 0 to 55 C 32 to 131 F when operating and 20 Ambient temperature 75 C 4 to 167 F when stored General T paoe withstand 500 V AC for one minute Between all caton Voltage terminals and the Insulation resistance 5MQ or more by 500V DC 9found terminal speed Communication Trans Somes FulkduplovHarkdupiex mission Transmission method Base band specifi cations Maximum segment 149 4 length 100m 328 1 Maximum number of Cascade co
27. rface is rough undue force will be applied to the PC board thereby causing nonconformities Install the product securely using a DIN rail or mounting screws When drilling screw holes or wiring make sure that cutting or wire debris dose not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Be sure to remove the dust proof sheet from the PLC s ventilation port when installation work is completed Failure to do so may cause fire equipment failures or malfunctions Connect extension cables securely to their designated connectors Loose connections may cause malfunctions 2 1 Mounting The FX3U ENET L can be mounted directly using screws or on a DIN rail DIN46227 2 1 1 Direct Mounting The FX3U ENET L can be mounted with M4 screws by using the direct mounting holes A space of 1 to 2 mm 0 04 to 0 08 between each unit is necessary 2 1 2 DIN Rail Mounting The FX3U ENET L can be mounted on a DIN rail DIN46227 35mm width 1 Fit the upper edge of the DIN rail mounting groove fig A onto the DIN rail 2 Push the unit onto the DIN rail 2 1 3 Procedure for connecting with the FX3u Series PLC When connecting to an FX3uU Before connections turn off the power to the PLC 1 Remove the extension device connector cover of the main unit corresponding connector as shown to the right N 3 Reattach the extension device connector cover on the main unit us
28. s of electrical shock 417 IEC 5036 on the enclosure of the final equipment 4 1 Grounding Other oes Pee ec Independent grounding Best condition Common grounding Not allowed Shared grounding Good condition Wiring and power supply wiring between PLC and FX3U ENET L Example usage of FX3U Externally power supply for FX3uU ENET L 24V DC D Grounding 100 Q or less Ethernet modular jack _ RJ 45 HUB This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles
29. signed to ensure safe machinery operation in such cases DESIGN PRECAUTIONS CAUTION e Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise 1 Do not bundle the main circuit line together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likey to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit or high voltage lines 2 Ground the shield wire or shield of a shielded cable However do not ground them at the same point as the high voltage lines e Install module so that excessive force will not be applied to the unit or cables Failure to do so may result in wire damage breakage or PLC failure STARTUP AND MAINTENANCE DANGER PRECAUTIONS Do not touch any terminals or connector while the PLC s power is on Doing so may cause electrical shock or malfunctions Before cleaning or retightening screws externally cut off all phases of the power supply Failure to do so may cause malfunction or failure of this unit When the screws are tightened insufficiently they may fall out and cause a short circuit or malfunction When tightened too much the screws or the unit may be damaged resulting in short circuit or malfunction When controlling the PLC especially when changing
30. the PLC can be sent and received via Ethernet by using When a parameter setting error occurs in the Ethernet unit CAUTION fein as anc RA sight onan ee Sonus GX Developer Ver 8 88S or later When an operational error occurs in the PLC CPU or physical damage MACUTEC IYE 2 Communication between PLCs or with a general Ethernet device is possible by When an error is found in the Ethernet unit H W error Mitsubishi Electric Corporation i i i 1 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan fixed buffer communication TCP IP or UDP IP D di the ci t d indicat CAUTION 3 Users can develop custom software to communicate with the PLC by using MC Pin Configuration S i aaa AROS MUO E may Manutactured ar f se wis MELSEC Communication protocol A compatible 1E frame subset for details The pin ae ration of FX3U ENET L RJ45 type modular jack for category 5 or also cause severe injury Mitsubishi Electric Corporation Himeji Works j p tigu yp J gory It is important to follow all precautions for personal safety 840 Chiyoda machi Himeji Hyogo 670 8677 Japan refer to user s manual TCP IP or UDP IP category 3 is as follows Ve j ity 4 E mail can be sent SMTP protocol e Authorized Representative in the European Community Associated Manuals Mitsubishi Electric Europe B V 5 The FX3U ENET L parameters can be set easily using FX Configurator EN L Pin No Signal Direction Contents Gothaer Str 8 40880 Ratingen Germany 6
31. ution for EC Directive e Installation in Enclosure Programmable logic controllers are open type devices that must be installed and used within conductive control cabinets Please use the programmable logic controller while installed within a conductive shielded control cabinet Please secure the cabinet door to the control cabinet for conduction Installation within a control cabinet greatly affects the safety of the system and aids in shielding noise from the programmable logic controller 3 Specification For details on specifications refer to the following manual Refer to the FX3U ENET L User s Manual DESIGN PRECAUTIONS lt SDANGER e Make sure to include the following safety circuits outside the PLC to ensure safe system operation even during external power supply problems or PLC failure Otherwise malfunctions may cause serious accidents 1 Most importantly have the following an emergency stop circuit a protection circuit an interlock circuit for opposite movements such as normal vs reverse rotation and an interlock circuit to prevent damage to the equipment at the upper and lower positioning limits 2 Note that when the PLC main unit detects an error such as a watchdog timer error during self diagnosis all outputs are turned off Also when an error that cannot be detected by the PLC main unit occurs in an input output control block output control may be disabled External circuits and mechanisms should be de