CA-A480-A : Reference & Installation Manual

image

Contents

1. Fire Control Override Jumper Settings ENABLED DISABLED FC OVERIDE FC OVERIDE ele_ If you are employing Fire Control with the CA A480 A be sure to wire the floor control relays using the Fail Safe method Refer to Fail Safe on page 8 for more information 12 REFERENCE amp INSTALLATION MANUAL DIP SWITCH SETTINGS SETTING THE CA A480 A S FLOOR ADDRESS DEFAULT OFF OFF OFF OFF When installing the CA A480 A elevator controller you must assign it to a door and floor address This address advises the CT V900 A controller which group of 16 floors it will be controlling and for which elevator car The CA A480 A s floor address is set through four DIP switches ADDRESS 1 ADDRESS 2 ADDRESS 4 and ADDRESS 8 To set the CA A480 A s floor address follow Table 1 below and turn on the appropriate DIP switches Refer to Figure 12 and to Figure 13 for more details Se Door 1 from the CT V900 A is used for Elevator Car 1 and Door 2 from the CT V900 A is used for Elevator Car 2 If connecting more than one CA A480 A to a CT V900 A controller make sure that you do not assign more than one CA A480 A with the same floor address Each CA A480 A up to 8 assigned to the same CT V900 A must have different floor addresses Table 1 CA A480 A Floor Address DIP Switch Settings ADDRESS 1 es 2 4 DES 8 OFF OF OFF Elevator Car1 Floors 1 to 16 RS A A Floors 17 to 32 isa 33 to 48 Ge er 49 to 64 ee ja Seat Car
2. common terminal Elevator Car Floor Button Button s input terminal J OR Fail secure Connection Method N O Floor Control Relay connection Floor Security Input terminal A sua CA A480 A Elevator Controller 10 REFERENCE amp INSTALLATION MANUAL JUMPER SETTINGS HIGH LOW E BUS IMPEDANCE J UMPERS DEFAULT HIGH These jumpers adjust the E BUS impedance These jumpers are only applicable if the CA A480 A is connected to the CT V900 A revision 200 or higher Normally both jumpers should be set to HIGH unless you are employing a set mode as described in the CT V900 A Installation Manual Refer to Figure 8 Figure 8 High Low E BUS Impedance Jumpers E BUS Jumper Settings Low Impedance High Impedance 5 eeje A e s oe A eee A LOW HIGH LOW HIGH LOW HIGH BEG e ejo B e s e B LOW HIGH LOW HIGH GEOL EOL JUMPER DEFAULT ON This jumper places the EOL termination of the CT V900 A controller s E BUS network in circuit If the CA A480 A that you are installing is the last module on the E BUS set the EOL jumper in the ON position If the CA A480 A that is being installed is not the last module on the E BUS set the EOL jumper in the OFF position For more information on EOL termination of the E BUS network refer to the CT V900 A Installation Manual Refer to Figure 9 for more details Figure 9 EOL Jumper Settings EOL Jumper Settings EO
3. 2 Connect the terminal of the battery to the BAT terminal of the CA A480 A The BATT LED will remain illuminated during normal operation If the battery s voltage drops below 10 5V the BATT TROUBLE LED will light up Refer to Figure 4 for more details Figure 4 Connecting the Battery Backup GEL CELL BATTERY 12 VOLT 7Ah CA A480 A Elevator Controller CA A480 A ELEVATOR CONTROLLER 7 FLOOR CONTROL CONNECTIONS The CA A480 A s floor control relays can be connected directly to the elevator s floor buttons Since the elevator is connected directly to the CA A480 A the user will then have to present their valid access card to the reader in the elevator car in order to access the floors The CA A480 A can be connected using two methods the Standard Button Control connection method or the Security Enabling Control connection method STANDARD BUTTON CONTROL CONNECTION This is the most commonly used connection method in elevator control applications The elevator car s floor selection buttons are controlled using the CA A480 A s floor control relays The Standard Button Control connection method can be applied in Fail Safe mode or Fail Secure mode Please note that for UL installations the button control connection must be configured in Fail Safe mode It is recommended that the voltage of the CA A480 A s floor control relays do not exceed 24VDC It is
4. Feer to 16 On OFF Floors 1710 32 ore ow fon for Fees ae ON jon Jon or gt oor 49068 Paue E aerer 12 General Overview of CA A480 A Floor Address DIP Switch Settings Door 1 Door 2 r Up to 4 Elevator Controllers CA A480 A per door CT V900 A Controller Floors Floors Floors 1 to 16 17 to 32 33 to 48 RS 485 CA A480 A A1 ON A2 OFF For Door 1 A4 0FF A8 OFF Floors Floors Floors 1 to 16 17 to 32 PR CA A480 A A1 ON A2 0FF A1 ADDRESS 1 DIP Switch A2 ADDRESS 2 DIP Switch A4 ADDRESS 4 DIP Switch A8 ADDRESS 8 DIP Switch For Door 2 A4 ON CA A480 A ELEVATOR CONTROLLER 13 Figure 13 CA A480 A Floor Address DIP Switch Settings I Mi f ld ADDRESS 8 RLY COMMS RLY OFF ON DRM ENABLE PWR OFF ON CA A480 A s Floor Address DIP Switches 1 to 4 CA A480 A Elevator Controller O Elevator Car 1 Elevator Car 1 Elevator Car 1 Elevator Car 1 Floors 1 to 16 Floors 17 to 32 Floors 33 to 48 Floors 49 to 64 ADDRESS 1 ADDRESS 1 ADDRESS 1 ADDRESS 1 ADDRESS 2 ADDRESS 2 ADDRESS 2 ADDRESS 2 ADDR ADDR ADDRESS 6 ADDRESS 6 ADDRESS 8 ADDRESS amp RLY COMMS j RLY OFFION DRM ENABLE PWR OFF ON PWR OFF ON NR OFEIO PWR OFF ON Elevator Car 2 Elevator Car 2 Elevator Car 2 Elevator Car 2 Floors 1 to 16 Floors 17 to 32 Floors 33 to 48 Floors 49 to 64 Jo ADDRESS ADDRE
5. STATUS LED Flashing Firmware is running smoothly Red COMM FAILURE LED ON The EM STATUS CA A480 A has lost communication Future Use gt FREE ACCESS _ with the CT V900 A Controller a COMM FAILURE BATT TROUBLE Red BATT TROUBLE LED ON The backup battery has dropped to 10 5VDC or lower 18 REFERENCE amp INSTALLATION MANUAL DESTINATION REPORTING MODULE DRM Normally when a user presents their access card to the reader in the elevator car the CA A480 A will activate and allow access to all the floors that the user is allowed to Though the controller will register the event if the user has access to more than one floor you won t know which floor the user has accessed With the Destination Reporting Module DRM sold separately the controller can register the user who accessed the elevator and which floor was accessed thus supplying an effective floor trace for each card holder Destination Reporting is also known as One Card One Floor operation as it only allows one floor selection to be made per presentation of the card BASIC OPERATION The DRM has 16 Floor Selection Inputs one for each floor control relay of the CA A480 A A person presenting their card will be allowed to select a floor that they have access to Pressing one of the connected elevator floor buttons will only activate the floor control relay corresponding to the selected floor thus allowing access to the desired floor The event
6. A480 A ELEVATOR CONTROLLER 19 Disconnect AC and battery power before mounting the DRM to the CA A480 A WIRING THE DRM AND CA A480 A The CA A480 A and DRM can only be wired using the fail safe connection method refer to page 8 Wire the DRM and CA A480 A as shown in Figure 20 To connect the DRM and CA A480 A 1 Connect the coM terminal of the selected floor control relay of the CA A480 A to the desired floor button in the elevator car 2 Connect the NC terminal of the selected floor control relay of the CA A480 A to the button input of the elevator control system 3 Connect the cow terminal of the DRM to the or ground of the elevator 4 Connect the selected IN Floor Selection Input of the DRM to the wire connecting the CA A480 A s com termi nal and the floor button in the elevator car Figure 20 Connecting the CA A480 A and DRM Elevator Control System Floor Button s Positive Voltage Floor Button s input terminal 2 CA A480 A Elevator Controller partial view F Loop terminal added by Installer o alla Elevator Car Floor Button To com input 2 terminal of desired D Floor Control Relay D Com Tg o To NC input 2 terminal of desired olo Elevator or Floor Control Relay olo Floor Button s GND DIO DIO cms _ Disconnect AC and battery power before wiring the DRM to the CA A480 A The elevator control system may provide a
7. PWR OFF ON _ During a communication failure During a communication failure the CA During a communication failure the the CA A480 A will do nothing y A480 A will deactivate all floor relays CA A480 A will activate all floor thatare currently activated relays that are currently deactivated 14 REFERENCE amp INSTALLATION MANUAL In order for the RLY OFF ON DIP switch to be used the RLY COMMS DIP switch must be in the ON position ENABLING THE DRM MODULE INPUT DEFAULT OFF The DRM ENABLED DIP switch DIP switch 7 will enable the DRM Destination Reporting Module header plug Once enabled a DRM can be connected directly to the CA A480 A s DRM header plug Refer to Figure 15 for more details For more information on the DRM please refer to Destination Reporting Module DRM on page 19 Figure 15 DRM DIP Switch Enable the DRM header plug by placing the DRM ENABLED DIP switch DIP switch 7 in the ON DRM MODULE position o ADDRESS 1 ADDRESS 2 PWR OFF ON INVERTING THE FLOOR CONTROL RELAYS PWR OFF ON DIP SWITCH DEFAULT OFF The PWR OFF ON DIP switch is used to invert the normal state of the CA A480 A s floor control relays This DIP switch is designed to be used with the Fail safe connection method page 8 This is important when integrating Fire Control with the CA A480 A With the floor control relay connected using normally closed contacts setting the PWR OFF ON D
8. ies Dee GD aA tale A a ered ae wae 13 Setting the CA A480 A s Floor Address Default OFF OFF OFF OFF 0 0 ccc ee ee eee 13 RLY COMMS and RLY OFF ON DIP Switches Default OFF 0 0 ee eee eee eee eens 14 Enabling the DRM Module Input default OFF 0 0 0 ee ee ee eee teen eens 15 Inverting the Floor Control Relays PWR OFF ON DIP switch default OFF 2 0 0 0 0 0 0 cee ees 15 FIRE CONTROL 4 402 taa bale beet ran EA A ee vee de EA os he ie 16 Wiring the GA A480 A s Fire Control INDUIS tidad ne a gt 16 CEDINDICATORS 2 3 33224 ad Ay Pe te a ee ee Ed We ae 2 aS 17 Green AC WED AA nn es wed RSR A he Mek fos Oa eae een CU M each en ob etal 17 Red Bal Reversed LED re ee a ee an ras reia id aes OU 17 Areces a ta ld o een 17 Green 121 Relay LED RS pr rico Ea des eee A Lee ee pio ess ee 17 G n BATE LED yaa si ds e Se ethers a SS IS A TES DAME on Ket oda 17 Green Status LED dt oo Beads NT da EN e Bee ee 17 EFIEBACCESE LED Zr ee S28 ad dd is a rd 4 IAEA 17 Red COMM irate LED ra oia ascitis ee aa e ad bas 17 Red BAIN TOUDE LED ceci arios ire os aaa adorada 17 DESTINATION REPORTING MODULE DRM asosan 19 BASIC ODEON SES ue rar dea tt o ia 19 Mounting the DAM iom to he CASRASO A eb weit ase te od dias alba lr au als dite 19 Wiring the DAM and CA BASOsA 3 tr 2a ea ee ba AAA as 20 BISCERIMER cd aca da at a on da career IC A A ee bang a Ce aa 21 WARRANTY DE A et sad 22 CA A480 A ELEVATOR
9. is a communication problem between the CT V900 A Controller and the CA A480 A If there is a communication failure between the CT V900 A and the CA A480 A the red LED will illuminate and will remain illuminated red until communication re established Refer to Figure 18 on page 18 for more details RED BATT TROUBLE LED This red LED indicates that the CA A480 A s backup battery has dropped to 10 5VDC or lower It will remain illuminated red until the battery s voltage is 10 5VDC or higher If the battery falls to below 8 5VDC the CA A480 A will shutdown Refer to Figure 18 on page 18 for more details CA A480 A ELEVATOR CONTROLLER 17 Figure 18 CA A480 A s LEDs Green ac LED ON AC power is present Green 12V RELAY LED ON floor control relays are receiving required n e oo te g req BATT REVERSED Red BATT REVERSED LED ON O aN ES Backup battery is hooked up in yi 12V RELAY EZ reverse BATT EM Green BATT LED ON backup battery detected Green 12V LED ON CA A480 A panelis receiving the 12VDC required to operate Red Rx LED Flashes whenever receiving data through the E BUS sssees maca ia 9066686586886 Red Tx LED Flashes whenever the CA A480 A is transmitting data through the E BUS Green FLOOR RELAY LED ON Floor control relay is activated All 16 floor control relays have an LED 9999999969998 Green
10. more details RED BATT REVERSED LED This LED indicates that the backup battery has been hooked up in reverse the CA A480 A s BAT terminal to the battery s negative terminal and the CA A480 As BAT terminal to the battery s positive terminal Refer to Figure 18 on page 18 for more details GREEN 12V LED This LED indicates whether the CA A480 A is receiving the 12VDC required to function properly When the CA A480 A is receiving 12VDC the green LED will remain illuminated Refer to Figure 18 on page 18 for more details GREEN 12V RELAY LED This LED indicates whether the CA A480 A s floor control relays are receiving the 12VDC required to operate properly When the 12VDC required for the floor control relays is present the green LED will remain illuminated Refer to Figure 18 on page 18 for more details GREEN BATT LED This LED indicates that the CA A480 A detects and is receiving the 12VDC from the backup battery When the battery is supplying 12VDC the green LED will remain illuminated Refer to Figure 18 on page 18 for more details GREEN STATUS LED This LED indicates whether the CA A480 A s firmware is functioning and communicating properly The green LED will flash continuously to indicate that the firmware is running Refer to Figure 18 on page 18 for more details FREE ACCESS LED Reserved for future use RED COMM FAILURE LED This LED indicates that there
11. 03 Position Technology Inc Specifications may change without prior notice All rights reserved Position Technology 780 Industriel Blvd Saint Eustache Quebec J7R 5V3 CANADA Tel 450 491 7444 Fax 450 491 2509 www postech ca PRINTED IN CANADA 10 03 CAA480A El01
12. BUS Elevator Car To ZA Floor Button To next Elevator CT V900 A J Control Elevator Controller pense system Controller Controller a eu z si Floor Control relays e Card Reader 2 for second Elevator Car Remove the connection between the CL ee TE YE Elevator Car Floor Button and the Elevator Control System Elevator Control system s Floor Button input terminal Elevator Car Floor Button s common terminal Fi CA A480 A Elevator Controller Elevator Car Floor Button Connect the Elevator Car _ Floor Button to the added loop Loop terminal added terminal by Installer 3 CA A480 A ELEVATOR CONTROLLER 9 FLOOR SECURITY INPUT CONTROL Some advanced elevators are not controlled using relays but through a microprocessor As well some of these advanced elevators provide additional connection terminals Floor Security Input terminals from which to connect security devices such as the CA A480 A So instead of connecting the CA A480 A to the elevator system floor button terminals as described in the Fail safe page 8 and Fail secure page 9 connection methods the CA A480 A will be connected directly to the supplied Floor Security Input terminals If this is so then a simple normally open Fail secure or normally closed Fail safe contact is connected to the elevators control system s Floor Security Input terminals depending on the elevator control system being used Verify with t
13. CA A480 A Elevator Controller O CE FE ANAD LISTED Reference amp Installation Manual Position Technology TABLE OF CONTENTS INTRODUCTION ios iaa rad a ence tna do ane ne tele Ge DS da GS ras 4 IATKOGUCHOM ze ok acs Paisa a I Se home A AE os AA 4 IDEE ICAO d SAR ee CR ag CRE a del cd a di a ee to bd a 4 LOCATION AND INSTALLATION A ee Gat aioe ae EA D ee Oe ek re 5 Localon and MOUNTING 2 ee ia erleiden ee eee es ee yds 5 Sa LATE MALE A RN Sie ee ad ca onan A inl AN 5 Installing a Controller Box Tamper Switch ur nn a a a 2 6 Connecting O A A ernten ne OS ee en ne a ee ah ke 206 atk Eistee EB Senne dae 6 Connecting th Backup BANC Aa sa see a e ao 7 FIODREONTROEEONNEETIONS dci a a EI FIT IE I Fa 8 Standard Button Control COnneClon 343025 A A Ae oe heed a Lt a ee 8 AA a ah cle ek de DS Ay S EE A a Pit RR te cee TS Se Ce NAS tare 8 FA DOCU ia edit xg fe dE A Ue se Be D ch od yet Bi tS laste end 9 Foor SecurielAput CONTO seria seat ek AS SG aaa he ac eS ne gue oe 10 JUMPER SETTINGS 3 50 rasos daria AA a Wood BE REE SBE Oe PEE EROS RARE SEES 11 High Low E Bus Impedance Jumpers Default High 20 0 0 0 ccc eee eee en enn 11 EOL Jumper Derat ONG ESS nn a isa ow Whe Sea oa ee eee Rah Sere Slee ad Rudi oe Boe wh ad a 11 350mA 700mA Battery Charging Jumper Default S50MA 0 eee eee eee ee eens 12 Fire Control FC Override Jumper Default DNA 12 DIPSSWTERFSETEINGS e ua see Done oe
14. CONTROLLER 3 INTRODUCTION INTRODUCTION The CA A480 A Elevator Controller gives you the ability to further secure a site By controlling the access to floors through an elevator you now have the means to further add to the security of a site With each CA A480 A controlling access to up to 16 floors 8 CA A480 A Elevator Controllers can be supported by each CT V900 A Controller Both doors from the CT V900 A can be assigned to an elevator car with a total control of 64 floors for each elevator car with the option of each floor control relay from the CA A480 A being directly interfaced with the elevator s floor control buttons In addition to advanced floor and elevator control features the CA A480 A also offers full supervision battery backup and fire control over how each floor operates If you have multiple floors and you need maximum control Position Technology s elevator control technology is the answer burglar alarm system All inputs shall be used to only monitor the door or elevator position The Model CA A480 A Elevator Controller has not been evaluated by Underwriters Laboratories Inc UL as a SPECIFICATIONS FLOOR CONTROL Number of Floors Maximum CA A480 A per controller Destination Reporting Individual Schedule Per Floor POWER SUPPLY AC Power Frequency Max Current AUX AC Loss Indicator ON BOARD PROTECTION Relay Control Auxiliary Output AC Protection Battery Reversal Protection Fu
15. IP switch to ON will open the relay During normal operation a user presents their card and pushes the desired elevator floor button which momentarily closes the relay and allows access to the selected floor During an emergency if the CA A480 A were to lose power the relay will revert back to its normal state normally closed As a result power can still be supplied to the elevator s floor buttons and allows the elevator to remain accessible For more information on Fire Control refer to page 16 Figure 16 PWR OFF ON DIP switch Putting the PWR OFF ON DIP switch in ADDRESS the ON position will invert the normal state of the CA A480 s elevator control relays ol DRM ENABLED CA A480 A ELEVATOR CONTROLLER 15 FIRE CONTROL The CA A480 A offers the ability to control the floor control relays in the case of a fire By wiring the floor control relays using the fail safe method and the CA A480 A to the building s or elevator car s fire control system the elevator can still be accessed during an emergency WIRING THE CA A480 A S FIRE CONTROL INPUTS with any components of the elevator system this includes the wiring of the CA A480 A s Fire Control inputs If connecting the CA A480 A to the building s fire control system consult with the building s technicians It is very important that a trained and registered elevator service company connect any wiring associated In order for the CA A480 A s fire control inputs to be enable
16. L OFF e e_JEOL Sample E BUS EOL Jumper Settings CA A480 A CA A480 A CA A480 A CA A480 A e Elevator Elevator Elevator Elevator CT V900 A Controller Controller Controller Controller A RE A CA A480 A ELEVATOR CONTROLLER 11 350mA 700mA BATTERY CHARGING JUMPER DEFAULT 350mA This jumper allows you to select the charging current for the backup battery of the CA A480 A Charging the battery at 350mA will take longer but consumes less power from the CA A480 A Charging the battery at 700mA takes less time but consumes more power from the CA A480 A Refer to Figure 10 Figure 10 350mA 700mA Battery Charging Jumper Battery Charging Jumper Settings 350mA 700mA e e ele 350mA 00mA 350mA 00mA FIRE CONTROL FC OVERRIDE JUMPER DEFAULT ON This jumper determines the CA A480 A s fire control override inputs When this jumper is ON even if there is a fire circuit connected to the CA A480 A s fire control inputs FC terminals the CA A480 A will ignore any signals coming to the FC terminals Refer to Figure 11 for more details For more information on the CA A480 A s fire control capabilities refer to Fire Control on page 16 If you are not using the CA A480 A s Fire Control terminals then the FC Override jumper should be in the ON position This will allow for full power to be supplied to the floor control relays Figure 11 Fire Control FC Override Jumper e
17. SS 2 ADDRESS 4 ADDRESS 1 ADDRESS 1 ADDRESS 1 ADDRESS 2 ADDRESS 2 ADDRESS 2 ADDRESS 4 ADDRESS 4 ADDRESS 4 ADDRESS 8_ ADDRESS 8 ADDRESS 8 RLY OFF ON RLY COMMS _ RLY COMMS AND RLY OFF ON DIP SWITCHES DEFAULT OFF The CA A480 A can be configured to activate or deactivate its floor control relays in the case of a communication failure with the CT V900 A controller The RLY COMMS DIP switch DIP switch 5 enables relay control during a communication failure The RLY OFF ON DIP switch DIP switch 6 determines whether the floor control relays are activated or deactivated during the communication failure Refer to Figure 14 Figure 14 CA A480 A Operation During a Communication Failure CA A480 A ls Elevator Controller The RLY COMMS DIP switch DIP switch 5 enables relay RES control during a communication failure The RLY OFF ON DIP switch DIP switch 6 determines whether the floor control relays are activated or deactivated during a communication failure RLY COMMS and RLY OFF ON DIP switches are ON The RLY COMMS DIP switch is ON The RLY OFF ON DIP switch is OFF RLY COMMS and RLY OFF ON DIP switches are OFF ADDRESS 1 ADDRESS 2 ADDRESS 6 ADDRESS 1 ADDRESS 2 ADDR ADDRESS 1 L ADDRESS 2 ADUR RLY COMMS RLY OFF ON RLY COMMS RLY OFFION DRM ENABLED NK Orr RLY COMMS RLY OFFION DRM ENABLED PVR Py C AR DRM ENABLE
18. d the Fire Control FC Override jumper page 12 must be in the OFF position Make sure that the CA A480 A s floor control relays have been wired using the fail safe method page 8 and that the PWR OFF ON see page 15 DIP switch has been set in the ON position Wire the building s or elevator car s fire control system to the CA A480 A s Fire Control Inputs as shown in Figure 17 Figure 17 Wiring the CA A480 A s Fire Control Inputs Make sure that the Fire Control FC Override jumper is in the OFF position Elevator Car s or Building s Fire Control System N C contacts r EE E m E E FC OVERIDE GND C o O O BATT REVERSEDI ns _ 12V RELAY IL C BATT IL DRM MODULE CA A480 A Elevator Controller Elevator Control System Elevator Car Floor Button s common terminal Floor Button Y i Ei E Floor Button s input terminal la Y L 2 ADDRESS 1 ADDRESS 2 RLY OFFION DRM ENABLED PWR OFF ON RL13 ss666666666 666s BWR OFFIC RL11 RL12 Loop terminal added E by Installer Make sure that the PWR OFF ON DIP switch is in the ON position Wire all floor control relays using the fail safe method 16 REFERENCE amp INSTALLATION MANUAL LED INDICATORS GREEN AC LED This LED indicates that the CA A480 A is receiving AC power When AC is present the green LED will remain illuminated Refer to Figure 18 for
19. ections 15cm 6 high x 6cm 2 5 wide x 10cm 4 deep Multiple Conduit Knock outs Two 2 5cm 1 or 3 1cm 1 25 and one 1 2cm 0 5 or 1 9cm 0 75 on each side Minimum Clearance for Cabinet 25cm 10 clear space around all sides 38cm 15 clear space in front of cabinet Minimum Clearance from Electrical Interference 2 4m 8ft from high voltage equipment wiring and from electrical equipment likely to generate interference 1 2m 4ft from telephone equipment or lines and 8m 25ft from transmitting equipment CONNECTING THE E BUS The CT V900 A Controller uses the E Bus to communicate with all accessories in the system All information programming data etc is accomplished through the E BUS Refer to Figure 1 for more details To connect the CA A480 A to the E BUS 1 Connect the A terminal of the CA A480 A to the A2 terminal of the CT V900 A 2 Connect the B terminal of the CA A480 A to the B2 terminal of the CT V900 A 3 Connect the GND terminal of the CA A480 A to the GND terminal of the CT V900 A Figure 1 Connecting the E BUS CA A480 A Elevator A Controller lat To Next CA A480 A Controller is Elevator Controller CA A480 A ELEVATOR CONTROLLER 5 INSTALLING A CONTROLLER BOX TAMPER SWITCH Installing a tamper switch allows the CT V900 A controller to detect when the CA A480 A s cabinet door is opened or when the cabinet is removed fro
20. he elevator company that installed or maintains the elevator control system whether their system follows N O or N C operation and have the terminals wired according to their requirements Connect the cow terminal of the desired floor control relay from the CA A480 A to the appropriate elevator control system Floor Security Input common terminal Then connect either the No or Nc terminal from the desired floor control relay of the CA A480 A to the appropriate elevator control system Floor Security Input terminal Refer to Figure 7 for more details with any components of the elevator system this includes the wiring of the CA A480 A s floor control It is very important that a trained and registered elevator service company connect any wiring associated relays Figure 7 Security Enabling Control To YX 777 Floor Security Input 77 A terminals l Elevator CA A480 A CT V900 A c Lal A Control Elevator Controller Elevator system Controller Controller al Floor Control relays Card Reader for second Elevator Car ELA STS SES SRS REESE SERRE REESE REE REE RRR RRR ERR RRR REE EM Elevator Control System Fail safe Connection Method N C Floor Control Relay connection Button s common Elevator Control o a RP CA A480 A Elevator Controller S ADDRESS1 ADDRESS DORE ADDRESS 8 RLY COMMS RLY OFF ON DRM ENABLED PWR OFF ON Floor Security Input
21. m the wall Refer to Figure 2 and install the tamper switch as follows 1 Insert the metal bracket in the cabinet slot before installing the cabinet on the wall 2 Insert the tamper switch in the metal bracket s 2cm 0 75 hole 3 Connect two 20cm 8 wires to the tamper switch terminals 4 Connect the tamper switch to the TAMPER terminals of the CA A480 A Figure 2 Tamper Switch Installation EBUS N INSERT BRACKET IN nn gt CABINET SLOT METAL BRACKET f CA A480 A ELEVATOR CONTROLLER TAMPER SWITCH If you are not using a tamper switch be sure to short the tamper inputs by connecting a wire between the two TAMPER terminals CONNECTING AC POWER A 15A AC power source with a dedicated breaker and an isolated ground is recommended Connect a 16VAC 40VA minimum transformer to the CA A480 A s Ac terminals and mount it near the cabinet Refer to Figure 3 Figure 3 Connecting AC Power TRANSFORMER 16VAC 40VA 50 60Hz Class 2 D O CA A480 A 7 Elevator Controller Do not power up the CA A480 A Elevator Controller until all connections and the CA A480 A settings are A completed 6 REFERENCE INSTALLATION MANUAL CONNECTING THE BACKUP BATTERY The CA A480 A uses a 12VDC 7 Ah gel cell battery for its backup power supply To connect the backup battery 1 Connect the terminal of the battery to the BAT terminal of the CA A480 A
22. oller Floor Control relays Card Reader 2 for second Elevator Car Elevator Car Floor Button and the Elevator Control system s Floor Button input terminal the PWR OFF ON DIP switch must be in the ON position CA A480 A Elevator Controller OL ADDRESS1 7 PWR OFFION NR OFEN Elevator Car Floor Button Connect the Elevator Car a Loop terminal added Floor Button to the added loop by Installer terminal A ee a 8 REFERENCE amp INSTALLATION MANUAL FAIL SECURE Connecting the CA A480 A using the fail secure method offers more security in the case of a power or communication failure If either were to occur then the elevator car s floor buttons would become inoperative Refer to Figure 6 Connecting the CA A480 A in the fail secure method 1 Connect the cow terminal of the desired floor control relay from the CA A480 A to the desired elevator control system floor button input terminal 2 Remove the connection between the elevator car floor button and its corresponding elevator control system floor button input 3 Using a loop terminal added by the installer connect the NO terminal of the desired floor control relay from the CA A480 A to the added loop terminal Then connect the elevator car floor button to the added loop terminal Figure 6 Standard Button Control Fail Secure Elevator Car Floor Buttons Floor Button connection wires E
23. positive or negative button control voltage The appropriate floor selection input will need to be wired to reflect this The above diagram shows it wired for a positive button control input A A 20 REFERENCE amp INSTALLATION MANUAL DISCLAIMER It is very important that a trained and registered elevator service company connect wiring associated with any component of the elevator system this includes the wiring of the CA A480 A Elevator Controller s floor control relay terminals Under no circumstances does Position Technology or any associated company accept any liability for the improper installation or commissioning of a CA A480 A Elevator Controller It is the responsibility of the installation company and the elevator company to ensure the personal safety of occupants using the elevator We recommend that the system uses the fire control from the fire switch used on the elevator and that the Standard Button Control Fail Safe Method described on page 8 be incorporated into the system This ensures operation regardless of the situation and gives the ability to manually bypass all floor security in the event of a fire or system trouble CA A480 A ELEVATOR CONTROLLER 21 WARRANTY Position Technology Inc Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year Except as specifically stated herein all express or implied warranties whatsoever statutory or o
24. se Failure Indication BATTERY BACKUP Battery Capacity Low Battery Low Battery Restore Low Battery Cut off OUTPUTS Relay Outputs INPUTS Fire Alarm Inputs Controller Tamper COMMUNICATION Expansion Bus E BUS MISCELLANEOUS Operating Temperature Specifications may change without prior notice A REFERENCE amp INSTALLATION MANUAL 16 8 Yes requires a DRM Interface Card for every CA A480 A Yes 16VAC 40VA MAX Amseco Model XP 2440 50Hz 60Hz 500mA Yes 2A Fuse 2A Fuse 3A Fuse 7A Fuse Indication of Battery Reversal All Event Generated 12VDC 7Ah 10 2VDC 12 2VDC 8 5VDC 16 Relay Outputs 15A tested by UL at 10A 16VDC Resistive 1 N C 1 N C RS 485 Plug and Play 0 C to 49 C 82 F to 120 F LOCATION AND INSTALLATION LOCATION AND MOUNTING The CA A480 A Elevator Controller comes as a printed circuit board PCB only or with a cabinet The cabinet is designed to allow easy and simple installation of floor control wiring the backup battery and interface connections The ideal location to install your CA A480 A is as close to the elevator control system as possible This will aid the elevator company by limiting the amount of wire needed to connect each floor that is controlled by the CA A480 A Cabinet Dimensions 39cm 15 57 high x 33cm 13 wide x 10cm 4 deep The cabinet can accommodate Up to two 12V 7 Ah gel cell type batteries and wiring conn
25. therwise including without limitation any implied warranty of merchantability and fitness for a particular purpose are expressly excluded Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product s inability to operate Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications Returns must include proof of purchase and be within the warranty period In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from the improper incorrect or otherwise faulty installation or use of the merchandise sold Notwithstanding the preceding paragraph the Seller s maximum liability will be strictly limited to the purchase price of the defective product Your use of this product signifies your acceptance of this warranty BEWARE Dealers installers and or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller 20
26. very important that a trained and registered elevator service company connect any wiring associated with any components of the elevator system this includes the wiring of the CA A480 A s floor control relays FAIL SAFE When connecting to the elevator we recommend that you use the fail safe method This ensures elevator operation regardless of the situation and gives the ability to manually bypass all floor security in the event of fire or system trouble This method is also used for Fire Control as well see Fire Control on page 16 Refer to Figure 5 for more details To connect the CA A480 A in fail safe 1 Connect the cow terminal of the desired floor control relay from the CA A480 A to the desired elevator control system floor button input terminal 2 Remove the connection between the elevator car floor button and its corresponding elevator control system floor button input 3 Using a loop terminal added by the installer connect the NC terminal of the desired floor control relay from the CA A480 A to the added loop terminal Then connect the elevator car floor button to the added loop terminal Figure 5 Standard Button Control Fail Safe Elevator Car Floor Buttons _ Elevator Car Floor Button connection wires El Elevator Car To Y Floor Button E i i Elevator serminals CA A480 A CT V900 A c N Control Elevator Controller Eletator E System T Controller Contr
27. will be logged through the controller as an Access granted valid floor selection with the floor that was selected In the case of a floor being selected that the user does not have access to the event Invalid Floor Selection will be generated and the user will need to present their card again and then select another floor In all cases once a card is presented the user can only select one floor Once the floor is selected by pressing the desired elevator floor button the user must present their card again in order to select another floor even if the floor selected was an incorrect one MOUNTING THE DRM ON TO THE CA A480 A The DRM connects directly to the CA A480 A s DRM Module header plug using a 14 pin cable The DRM is designed to be mounted on plastic standoffs Supplied with the DRM and fastened to the CA A480 A using 4 screws The DRM comes with 16 floor selection inputs one for each floor control relay on the CA A480 A Before connecting the DRM make sure that DIP switches 7 DRM ENABLED and 8 PWR OFF ON are in the ON position Refer to Figure 19 for more details Figure 19 Mounting the DRM Nylon Screws _ gt i x 4 14 pin Flat Han Cable CA A482 P CA A480 A Elevator Controller Plastic Standoffs x 4 Ol LALA switches 7 DRM ENABLED and 8 PWR OFF ON from the CA A480 A must be in the ON position nescosesoeeel sessesesesee ee PO CA