BT-user manual

image

Contents

1. with optional time setting to Doctor s preference Mode 3 Pulse mode Full Power 1 second on 1 second off Default Time 20 seconds with optional time setting to Doctor s preference 1 Once the user sets the mode M1 or M3 please press the TIME button continuously for longer than 2 seconds till the number shown in the LCD panel starts to blink and press again to change time a second per push 2 Operating time will start add up after one second if the user pushes the TIME button continuously 3 Press the ON OFF SET button to set the timer according to users preference Operation 1 After setting up the MODE selection and operating time please press the ON OFF SET button to start 2 Press again to stop operation at any time 3 Auto Power Saving Mode the device will turn off automatically if it is left idled for longer than 90 seconds Operation restarts once the user presses the trigger 4 Under M1 8 seconds setting the device can be continuously utilized for approximately 30 curing sessions Caution Operating BT 150 at Mode 1 8 seconds for more than 30 cycles continuously could result in high temperature accumulation which is hazardous to the health of patient s teeth Cooling System BlueLEX GT 1500 is equipped with a special built in magnetic fan motor to prevent over heating and to prolong the light emitting time IMPORTANT gt The cooling system will be activated wit
2. MIONITEX BlueLEX BT 150 The innovative corded LED curing light User Manual Table of Contents PREFACE cca ee a tte meee EREE 1 DISCLAIMER soir 2 SAFETY PRECAUTIONS sesak i ctececee cee 2 PARTS AND FUNCTIONS 220 3 GENERAL INSTALLATION 4 OPERATION teeseen a 4 COOLING SYSTEM Sare E 6 TROUBLE SHOOTING TIPS 7 SPECIFICATION 2 22 2 222 2oeenenee 7 PREFACE 1 Thank you for choosing Monitex Product for your advance integration Prior to using the Digital X Ray Film Scanner please read this User Manual carefully and keep this manual well preserved for future reference 2 Please contact your local dealer if any damage or problem occurs Attempt to try and repair this unit by unauthorized technician personnel WILL automatically lead to the forfeit and negation of the warranty agreement 3 The specifications are subject to change and revision without prior notice 1 DISCLAIMER 1 Monitex shall not assume any responsibility if any malfunction or damage was caused by improper operation removal modification or maintenance We shall not assume any responsibility if any malfunction or damage was caused by operating under unsuited environment We shall not assume any responsibility if any malfunction or damage was caused by forceful majeure We reserve the right to explain f
3. ct Cleansing If there is any dirt or stains on the surface of control panel or handpiece please use cloth to wipe amp clean If the stain is serious then please use a neutral cleaning agent Note Never use a solvent or volatile oil for cleaning This can lead to fading in the fiber optic shades PARTS amp FUNCTIONS Three modes ON setting button OFF M1 Full Power SET M2 Ramp M3 Pulse Time setting button GENERAL INSTALLATION Please follow the instructions below carefully to ensure proper function of the device 1 Insert the fiber optic probe into the handpiece and make sure it is securely installed at the fixed position 2 Connect the power cable and plug to an electric outlet 3 Put on the anti glare cone and the protective shield and adjust the cone and shield position according to the dentist s preference OPERATION Thermometer The thermometer sign will blink after continuous usage of 30 consecutive sessions with each session lasts for 30 seconds This function will shut off the unit to prevent the device from over heating MODES There are 3 modes at your choice The working time of each mode can be reset according to Dentist s preference Timer Mode E m 1 T ji IZ to Time Setting Mode 1 Full power Default Time 8 seconds with optional time setting to Doctor s preference Mode 2 Ramp Power Default Time 15 seconds
4. h F the motor fan starts turning when the heat starts to accumulate gt The Thermometer Sign will start to blink and shut off the system for complete cooling and for protection purpose TROUBLE SHOOTING TIPS CAUTION When failure or error occurs please refer to following solutions to check the device If problem remains please contact your nearest local dealer for repair or maintenance DESCRIPTIONS FAILURE CAUSE SOLUTION LCD device is Defect in LCD unable to lightup device or pc board Return for repair Defect in main IC board Return for repair No activation Poor connection of the cable or plug LED lamp is unable Defect in IC board or to emit LED module Check the connection Return for repair SPECIFICATIONS ADAPTER CURING HANDPIECE Input AC100V 240V 50 60 HZ LED lamp 5 Watt Output DC9V Voltage AC 100V 240V 50 60 Hz Current 1 3A TYPICAL ight A we WEEDE ABROR ANR E LIGHT GUIDE Light Intensity up to 1 000 mW cm Wavelength 450 470 nm Dimesion Approx 19 75x4 24x7 7cm Fiber optic with tapered tip 10mm taper to 8mm Weight Approx 25g Autoclavable up to 134 C
5. or the given cause of the Defective products which might have been caused by natural disasters or abnormal temperature humidity that is inconcurrent to the guidance instructed in this manual SAFETY PRECAUTION Please follow instruction steps in this manual for correct and safe operations of the device Pay special attention to the following warning signs beside the operation descriptions where applicable Warning Beware of high temperature and strong light DO NOT look directly into the light source which might cause bodily harm to one s eyes 1 Danger This message appears where the operation may potentially cause severe injury if instruction not followed correctly Warning This message appears where the operation may cause serious damage or defect to other objects Caution This message appears where the operation may cause slight damage to other objects or slight bodily harm if operation not properly conducted Important This message appears where the operation may involve risk of defecting the device itself if not properly conducted 2 Sterilization for Fiber Optic Tip After operation on each patient the fiber optic tip should be disinfected or sterilized Please autoclave the tip to 134 C 75 psi for maximum cleansing result The sterilization time at 134 C should be 5 minutes Note Please disconnect the fiber optic tip off the handpiece and autoclave it by itself Produ