1. 2 DocUReader User s Manual Error messages and Troubleshooting In case of malfunction error messages will be printed out by the DocUReader Sign Name of the sign What does the sign mean E 1 REF pad error REF pad values out of range E 2 Tray positioning err Missing tray hole is not transparent or friction drive lost E 3 Dry strip Strip not moisturized correctly E 4 Measurement error Wrong strip type or incorrect strip positioning E 5 Firmware error Firmware key is missing or damaged The first indicator LED is blinking Instrument hardware error contact your distributor Serial Interface The DocUReader can be connected to a host PC through its serial interface Please contact your distributor for details Maintenance Cleaning up the strip tray Remove the tray by drawing it all the way right Wash it up with soap water or isopropyl alcohol Also make sure that the positioning hole is transparent Pay special attention while cleaning the grey REF pad try to avoid in any way of scratching its surface Wipe it with a soft cotton cloth Make sure to have it dried completely Replace the tray and align its right edge to the right edge of the device house Calibration and Checking functions The calibration function is executed automatically during every strip reading with the help of the REF pad to be found on the strip tray DocUReader built in program has a so called Check mode control option
2. in order to let the user check the optical reading system with the help of gray check strip holder shipped together with the device The Check mode can be selected by enabling DIP switch no 2 Then insert the Gray Check Strip into the DocUReader Press the Start button The device executes the checking function then prints out the results If results are out of the ranges indicated on the label fixed on the inner side of the printer cover first clean and check the REF pad of the strip tray if it is contaminated or damaged If it seems to be OK have the device performed a checking function again If results are still not within the ranges the DocuReader needs professional troubleshooting and or repair service so contact your local distributor DocUReader User s Manual DocUReader User s Manual DocUReader User s Manual DIP switch settings Parts and accessories oll 77 Elektronika Co Ltd Please indicate the name the Cat No and the quantity if ordering iene 99 H1 116 Budapast The reader can be controlled manually by setting of DIP switches on the back side There are four Thermal printer paper 1 roll 612EPL19 Tel 36 1 206 1480 Fax 36 1 206 1481 switches with different functions When the toggle is in upper position the switch is enabled otherwise is Serial interface cable AMT 4616 1 e mail sales e77 hu disabled The functions from leftmost seeing from back Check tray for function test UDR 440
3. Dip the strip into the tube containing urine sample next in line then remove it Let the excess urine drop back into the tube still remaining excess urine can be removed by drawing the edges of the strip on a piece of tissue paper 4 Place the strip upward with PADs on the tray Make sure that the strip front edge bumps against he end of the tray i e the strip is correctly placed The reagent strip must be tested in 50 seconds after being moisturized The time passing by is indicated by the activation of LED row on the top of the instrument Green LED indicators are activated successively in every 5 seconds but the last three indicators will be lighted up in red color as a warning sign for the user that the incubation time is over soon 5 From this phase the process of the test and evaluation will be performed automatically by the DocUReader control program it determines all PADs reagents concentrations one by one 6 Wait while the DocUReader ejects the strip tray and the test results are printed out LEDs colors are lighted up according to the result values green color means normal red color means pathological result Each LED represents a reagent identified with its three letter code printed next to the indicator In case of LabStrip U11Plus the result of the Ascorbic Acid iis not indicated among LEDs Remove and discard the used strip from the tray 7 Finishing your daily routine work always clean the strip tray under running water
4. 4 1 web www e77 hu Gray plastic strip for function test UMC 1117 1 Measurement system Strip tray for LabStripU11Plus UMC 4411 2 1 Unit selection in print out External power adapter 1ASA7V1A ON 2 SI units enabled User manual UDR 9201 4 OFF conventional units enabled 2 Check mode selection The check mode is to test the instrument Selecting this mode you should insert the strip tray only The instrument measures the reflectance value of the grey calibration pad and prints out the remission values The values should be within the Bil ranges indicated on the inner side of the printer coves Urobilinogen C ON check mode enabled OFF check mode disabled 3 Printer enabled disabled When printer is disabled the results are displayed only by the 5 indicator LEDs Since the instrument has no data memory in this mode it is not possible Fee AOE 10 to print the results later It is suggested to use this feature only in case of on line computer connection and data evaluation BSE 2 ON printer disabled Glucose 500 OFF printer enabled 8 5 28 4 To print out the remission values In this mode besides the results the measured reflectance values are printed too 1 ON remission value print out enabled i OFF remission value print out disabled pos Ooo IVD In Vitro Diagnostic Device for professional use Technical features 1 008 aal Menutaoturer type reflectance photometer throughput 40 strips hour size 250 x 120 x 70 mm waveleng
5. DocUReader User s Manual A N Warning Read this before using the equipment Always read and follow the instructions described in this manual and in the LabStrip U11Plus user manual Never use other devices power adapter or accessories than shipped or supplied by the manu facturer or distributor Never store install or use the devices supplies and test strips on other way than described in their user manual Never rely exclusively on the test results provided by the DocuReader when set up a diagnose instead apply all available diagnostic method as well If you have any doubt if the measured value being correct perform a test in Check mode See chapter Calibration and Checking function Medical laboratory staff members should already meet the fallowing professional requirements before using the equipment Knowledgeable and experienced in general laboratory testing practices Being introduced the information described in this guide Introduction IVD C DocUReader compact size urine analyzer working exclusively with the LabStripU11Plus multi reagent strip and providing semi quantitative reagent concentration values in urine Firmware FEED button printer cover Start button Slot feeder slot Power socket serial interface DIP switch positions OFF down ON up 1 Measuring UNIT selection off conv on Sl 2 CHECK Mode enabled disabled on enabled 3 PRINTER Enabled Disabled on disabled 4 SERVICE po
6. sitioning test enabled disabled thermo paper strip tray strip holder REF pad positioning hole Package content 1 pc DocUReader instrument 1 pc black strip tray for LabStripU11Plus test strip 1 pc external power adapter 1 roll of thermo printer paper 2 pc gray Check strip DocUReader User s Manual Installation 1 Insert the LabStripU11Plus tray and align its right edge to the outer right end of the instrument house 2 Connect the DC side power cord connector of the AC DC adapter to the socket marked with power socket on the DocUReader rare side 3 Plug the AC cord of the adapter into the wall socket A short initialization phase starts while the strip tray starts to move for self check and a message is printed out if paper is loaded Inserting new printer paper Open the printer cover Pressing the FEED button remove the paper left if necessary Press FEED button again to stop the feeder function Insert the prepared cut end of the new roll of paper into the feeder slit Forward the paper by pressing FEED button Lead the paper through the feeder slot and close the printer cover e Steps of the routine operation 1 Place the test tubes of prepared urine samples next to the DocUReader and take a vial of test strips Open the vial by removing its cap take a strip out by holding its handle and replace the cap 2 Press the device Start button 3
7. ths 430 555 650 nm A Warning weight 820 g power adapter 7 5VDC 1 25A interface RS232 ser port unidir max 2400 Baud printer internal thermo printer 24 char row op temperature 15 35 C Ci Consult user manual relative humidity lt 80 C storage shipping 10 50 C Product certified in EC ver 3 1 4
Download Pdf Manuals
Related Search
Related Contents
GE GFK-1852 User's Manual DLA-X95R DLA-X75R DLA-X55R DLA-X35 Conserver ce manuel pour des futures consultations ( E Istruzioni CT5 - Fantini & Cosmi Benutzerhandbuch S.H.Figuarts ゴウライジャーセット 取扱説明書 351.6 KB 取扱説明書 FT 025 Alimentations continues linéaires rapides type PS Johnson RSV135 User's Manual Copyright © All rights reserved.