Installation Manual of Room Air Conditioner
Contents
1. HSU 12HV03 R2 DB HSU 09HVA103 R2 DB HSU 22HVA103 R2 DB DB DB ua d BN re a CES Pi 140 500 140 583 113 5 Floor fixing dimensions of the outdoor unit Unit mm Floor fixing dimensions of the outdoor unit Unit mm Fixing of outdoor unit e Fix the unit to concrete or block with bolts 10mm and nuts firmly and horizontally e When fitting the unit to wall surface roof or rooftop fix a supporter surely with nails or wires in consideration of earthquake and strong wind e f vibration may affect the house fix the unit by attaching a vibration proof mat Selection of Installation Place Place robust not causing vibration where the body can be supported Place which is less affected by rain or direct sunlight and is sufficiently sufficiently ventilated e Place not affected by heat or steam generated in the vicinity where Place possible to bear the unit where vibration and noise are inlet and outlet of the unit are not disturbed not increased O Place possible to drain easily where piping can be connected with the Place where discharged wind and noise do not cause a outdoor unit nuisance to the neighbors e Place where cold air can be spread in a room entirely Place where a distance marked amp is available as illustrated O Place nearby a power receptacle with eno
2. drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Cover the connection part with heat insulation materials closely and make sure fixing with adhesive tape Heat insulation h Piping material Lid for right piping Pipe supporting plate i Lid for left piping Drain hose Indoor outdoor electric cable Lid for under piping Fix with adhesive tape e Indoor outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape Other direction piping e Cut away with a nipper the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole When bending be careful not to crash pipes e Connect beforehand the indoor outdoor electric cable and then pull out the connected to the heat insulation of connecting part specially Fixing the indoor unit body e Hang surely the unit body onto the upper notches of the mounting plate Move the body from side to side to verify its secure fixing A e n order to fix the body onto the mounting plate hold up the body aslant from the underside and then put it down a perpendicularly Y 4 Connecting the indoor outdoor Electric Cable Removing the wiring cover Remove termina
3. installer or local authority for more information Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation CONFORMITE AUX DIRECTIVES EUROPEENNES POUR LES MODELES CE Tous les produits sont conformes aux directives europ ennes suivantes Directive 73 23 CEE Basse tension Directive 2006 95 CE Basse tension Directive 89 336 CEE Compatibilit lectromagn tique Directive 2004 108 CE Compatibilit lectromagn tique ROHS L appareil est conforme a la directive 2002 95 CEE relative a la limitation de l utilisation de certains substances dangereuses dans les quipements lec triques et lectroniques DEEE WEEE Information au consommateur comme le pr voit la directive europ enne 2002 96 CE relative aux d chets d quipements lectriques et lectro niques SPECIFICATIONS POUR L ELIMINATION Ce pictogramme appos sur le climatiseur signifie que les quipements lectriques et lectroniques ne peuvent pas tre limin s avec les d chets m nagers non tri s Ne pas essayer de d manteler l quipement soi m me le d mant lement des systemes de clima tisation ainsi que la r cup ration du frigorigene de l huile et de toute autre partie doivent tre effectu s par un installateur qualifi conform ment a la l gisla tion locale et nationale en vigueur en la mati re Les climatiseurs doivent tre t
4. Installation Manual of Room Air Conditioner O Read this manual before installation O Explain sufficiently the operating means to the user according to this manual Necessary Tools for Installation 1 Driver 5 Torque wrench 17mm 22mm 26mm 9 Nipper 12 Reamer 2 Hacksaw 6 Pipe cutter 10 Gas leakage detector or 3 Hole core drill 7 Flaring tool soap and water solution 4 Spanner 17 19 and 26mm 8 Knife 11 Measuring tape Drawing for the installation of indoor and outdoor units X The models adopt HFC free refrigerant R410A Accessory parts Number f Accessory parts 9 articles Remote controller 1 Doro than 106 R 03 dry battery a Optional parts for piping Mounting plate Mark Parts name Non adhesive tape Drain hose Adhesive tape gt gt Saddle L S with screws 4X25 Plastic cap Connectin i g electric cable Screw for indoor and outdoor 7 Attention must be paid to R O Drain hose the rising up of drain hose Drain elbow Heating insulating material Piping hole cover Arrangement of piping directions Rear left L Left 4 lt gt Rear ia gt i Right Below X The marks from to in the figure are the parts numbers X The distance between the indoor unit and the floor should be No 0010 more than 2m HSU 07HV03 R2 DB HSU 18HV03 R2 DB HSU 09HV03 R2 DB HSU 07HVA103 R2 DB HSU 22HV03 R2 DB
5. alve 3 way valve 2 way valve 3 way valve HSU 07HV03 R2 HSU 09HV03 R2 HSU 12HV03 R2 HSU 18HV03 R2 DB HSU 12HVB03 R2 DB HSU 07HVA103 R2 2 way valve 3 way valve DB DB DB B HSU 09HVA103 R2 HSU 12HVA103 R2 D D D HSU 18HVA103 R2 D Valve rod cap S DO Valve rod cap Service port cap 2 Please do not let other cooling medium except specified one R410A or air enter into the cooling circulation system Otherwise there will be abnormal high pressure in the system to make it crack and lead to personal injuries 1 Power Source Installation e The power source must be exclusively used for air conditioner Over 10A e In the case of installing an air conditioner in a moist place please install an earth leakage breaker e For installation in other places use a circuit breaker as far as possible 2 Cutting and Flaring Work of Piping e Pipe cutting is carried out with a pipe cutter and burs must be removed e After inserting the flare nut flaring work is carried out A Flare tool for R410A Conventional flare tool Flare tooling die Clutch type clutch type Rigid type Wing nut type Imperial type 1 Cut pipe 2 Remove burs D 3 Insert the flare nut R de Correct Incorrect ji 4 Flare pipe Y y Y Bf Y Ef Lean Damage of flare Crack Partial Too outside 3 On Drainage Please install the drain hose so as to
6. be downward slope without fail Please don t do the drainage as shown below io Utg 7 ni 7 4 7 It becomes high midway The end is immersed It waves The gap with the ground There is the bad smell in water is too small from a ditch e Please pour water in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor e In case that the attached drain hose is in a room please apply heat insulation to it without fail Check for Installation and Test Run Please kindly explain to our customers how to operate through the instruction manual Check Items for Test Run o Put check mark v in boxes O Gas leak from pipe connecting O Is drainage securely carried out O Is the lamp normally lighting O Heat insulation of pipe connecting O Is the earth line securely O Are cooling and heating when O Are the connecting wirings of connected in heat pump performed normally indoor and outdoor firmly inserted O ls the indoor unit securely fixed O Is the operation of room temperature to the terminal block O Is power source voltage abided regulator normal O Is the connecting wiring of indoor by the code and outdoor firmly fixed O Is there any noise Haier AIR CONDITIONERS Haier Industrial Park No 1 Haier Road Qingdao P R China Q CONFORMIT ALLE DIRETTIVE EUROPEE PER MODELLI CE Tutti i prodotti sono conformi alle seguenti normative europee D
7. erante aggiuntiva nel campo e e 1 2 la carica di refrigerante totale sull etichetta di carica del refrigerante fornita con il prodotto L etichetta compilata deve essere collocata in prossimit della portata di cari ca del prodotto ad esempio nell interno del coperchio della valvola d inter cettazione A contiene gas fluorurati ad effetto serra inclusi nel protocollo di Kyoto B carica di refrigerante di fabbrica del prodotto vedi targhetta con il nome dell unit C quantit di refrigerante aggiuntiva nel campo D carica di refrigerante totale E unit esterna F cilindro del refrigerante e collettore di carica IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED This product contains fluorinated greenhouse gases covered by the Kyoto Protocol Do not vent into the atmosphere Refrigerant type R410A GWP value 1975 GWP global warming potential Please fill in with indelible ink ei the factory refrigerant charge of the product e2 the additional refrigerant amount charged in the field and e 1 2 the total refrigerant charge on the refrigerant charge label supplied with the product The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop valve cover nmo contains fluorinated greenhouse gases covered by the Kyoto Protocol factory refrigerant charge of the product see unit name plate additional refrigerant amount charged in the field total re
8. f Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2 Connection of pipes e To bend a pipe give the roundness as large as possible not to crush the pipe and the bending radius should be 30 to 40 mm or longer e Connecting the pipe of gas side first makes working easier eThe connection pipe is specialized for R410A Half union Flare nut Forced fastening without careful centering O A may damage the threads and cause a leakage of gas J Pipe Diameter Fastening torque Liquid side 6 35mm 1 4 Gas side 9 52mm 3 8 Torque wrench Spanner Be careful that matters such as wastes of sands etc shall not enter the pipe The standard pipe length is 5m If it is over 5m the function of the unit will be affected If the pipe has to be lengthened the refrigerant should be charged according to 20 g m But the charge of refrigerant must be conducted by professional air conditioner engineer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then charge additional refrigerant O Outdoor unit Outdoor unit Max Length A 20m for 07k 09k 12k A 25m for 18k 22k os C A Oil trap A FS Indoor unit A N By co Indoor unit S CAUTION e In case more than 5m 10m for 07k 09k 12k e Oil trap shoud be installed every 5 7m Tom for TAk 22k e no more gas if the
9. frigerant charge outdoor unit refrigerant cylinder and manifold for charging INFORMATION IMPORTANTE RELATIVE AU REFRIGERANT UTILISE Ce produit contient des gaz a effet de serre fluor s encadr s par le protoco le de Kyoto Ne pas laisser les gaz s chapper dans l atmosph re Type de r frig rant R410A Valeur GWP 1975 GWP potentiel de r chauffement global Pri re de compl ter l encre ind l bile e 1 la charge de r frig rant d usine du produit e2 la quantit de r frig rant suppl mentaire charg e sur place et e 1 2 la charge de r frig rant totale sur l tiquette de charge de r frig rant fournie avec le produit L tiquette compl t e doit tre appos e proximit de l orifice de recharge du produit par ex l int rieur du couvercle de la vanne d arr t A B TM 0 Q contient des gaz effet de serre fluor s encadr s par le protocole de Kyoto charge de r frig rant d usine du produit voir plaquette signal tique de l unit quantit de r frig rant suppl mentaire charg e sur place charge de r frig rant totale unit ext rieure cylindre de r frig rant et collecteur de recharge Haier AIR CONDITIONERS Haier Industrial Park No 1 Haier Road Qingdao P R China Contains fluorinated greenhouse gases covered by the Kyoto Protocol A INFORMACION IMPORTANTE EN RELACION AL REFRIGERANTE UTILIZADO Este producto contiene los
10. gases fluorados de efecto invernadora regulados por el Protocolo de Kioto No vierta gases a la atm sfera Tipo de refrigerante R410A Valor GWP 1975 GWP Potencial de calentamiento global Rellene con tinta indeleble e 1 la carga de refrigerante de f brica del producto 2 la cantidad adicional de refrigerante cargado en campo y e 1 2 la carga total de refrigerante En la etiqueta de carga de refrigerante suministrada con el producto La etiqueta rellenada debe pegarse cerca de la conexi n de carga del pro ducto p ej en el interior de la cubierta de la v lvula de tope A B mmuUuUuoO Contiene los gases fluorados de efecto invernadora regulados por el Protocolo de Kioto Carga de refrigerante de f brica del producto v ase placa de especifi caciones t cnicas de la unidad Cantidad adicional de refrigerante cargado en campo Carga total de refrigerante Unidad exterior Cilindro del refrigerante y dosificador de carga
11. he return to the beginning of e the valve rod for the 2 way valve to an angle of anticlockwise 90 degrees After 6 seconds close the 2 way valve and make Mot inspection of gas leakage In case of gas leakage tighten A parts of pipe connection If i i leakage stops then proceed steps gt 2 Detach the charge hose from the service port open 2 way valve and 3 way Turn the valve rod anticlockwise until hitting lightly P a To prevent the gas leakage turn the service port s cap the valve rod s cap for 2 way valve and 3 way s a little more than the point where the torque increases C suddenly y After attaching the each caps check the gas leakage around the caps CAUTION 1 If the refrigerant of the air conditioner leaks it is necessary to discharge all the refrigerant Vacuumize first then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate Close 2 way valve Liquid Side 3 way valve Gas Side 2 way valve 3 way valve 2 way valve 3 way valve If it does not stop gas leakage discharge whole refrigerants from the service port HSU 22HV03 R2 DB After flaring work again and vacuumize HSU 22HVA103 R2 DB fill up prescribed refrigerant from the gas cylinder 2 way v
12. irettiva 73 23 EEC Basso Voltaggio Direttiva 2006 95 EC Basso Voltaggio Direttiva 89 336 EEC Compatibilit elettromagnetica Direttiva 2004 108 EC Compatibilit elettromagnetica ROHS Il prodotto conforme alla normativa 2002 95 EEC sulla restrizione d uso di sostanze inquinanti negli apparecchi elettrici ed elettronici WEEE Informativa al consumatore come previsto dalla normativa europea 2002 96 CE riguardante i rifiuti di apparecchiature elettriche ed elettroniche SPECIFICHE DI SMALTIMENTO ll climatizzatore contrassegnato con questo simbolo ci significa che i prodotti elettrici ed elettronici non possono essere smaltiti insieme ai rifiuti domestici non differenziati Non cercare di demolire il sistema da soli la demolizioni dei sistemi di condizionamento nonch il recupero del refrigerante dell olio e di qualsiasi altra parte devono essere eseguiti da un installatore qualifi cato in conformit alla legislazione locale e nazionale vigente in materia l climatizzatori devo essere trattati presso una struttura spe cializzata nel riutilizzo riciclaggio e recupero dei materiali II corretto smaltimen to del prodotto eviter le possibili conseguenze negative all ambiente e alla salute dell uomo Per maggiori informazioni contattare l installatore o le autori t locali Le batterie devono essere tolte dal telecomando e smaltite separata mente conformemente alla legislazione locale e nazionale vigente in
13. it with the type of T 3 15A 250V A N PLP Ae 3 The wiring method should be in line with the local wiring standard NO ele eS 4 After installation the power plug should be easily reached Po a 5 POWER PLUG Indoor unit Outdoor unit Indoor unit HSU 07HV03 R2 HSU 22HV03 R2 DB HSU 12HVO3 RAl HSU 22HVA103 R2 DB HSU 18HV03 R2 HSU 12HVB03 R2 HSU 07HVA103 R2 DB HSU 09HVA103 R2 DB HSU 12HVA103 R2 DB DB DB DB Outdoor unit DB BB Power cable mod 07 09 12 3G1 5mm mod 18 22 3G2 5mm HSU 18HVA103 R2 claw of the clip 5 Easily demount cleaning of indoor unit 1 Top inlet can be taken down Open the inlet grille press the claw of the clip on the unit then take down the top inlet according to figure 1 Figura 1 2 Vertical flap can be taken down Overturn the vertical flap press the claw of the clip then take down vertical flap according to figure 2 3 Horizontal louvers can be taken down Figure 2 After taking down vertical flap Horizontal louvers are appeared draw c Daft g the middle louver and take down the horizontal louvers according to figure 3 Era 2 Figure 3 Outdoor unit 1 Installation o
14. l cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable after installing the indoor unit a 1 Insert from outside the room cable into left side of the wall hole in which the pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop Indoor unit When connecting the cable before installing the indoor unit e Insert the cable from the back side of the unit then pull it out on the front side e Loosen the screws and insert the cable ends fully into terminal block then tighten the screws e Pull the cable slightly to make sure the cables have been properly inserted and tightened e After the cable connection never fail to fasten the connected cable with the wiring cover Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person The type of connecting wire is HOSRN F or HO7RN F mod 07 09 12 4G1 5mm mod 18 3G2 5mm 1x1 0mm 3G2 5mm connect to 1 N 2 L O of the terminal 1G1 0mm connect to 3 C of the terminal mod 22 4G1 0mm 2 If the fuse on PC board is broken please change
15. length of connecting pipe is less than10m Max Elevation Ne 3 Connection e Use the same method on indoor unit Loosen the screws on terminal block and insert the plugs fully into terminal block then tighten the screws e Insert the cable according to terminal number in the same manner as the indoor unit e f wiring is not correct proper operation can not be carried out and controller may be damaged e Fix the cable with a clamp 4 Attaching Drain Elbow e f the drain elbow is used please attach it as figure Note Only for heat pump unit Outdoor unit 6 Purging Method To use vacuum pump Detach the service port s cap of 3 way valve the valve rod s cap for 2 way valve and 3 way s connect the service port into the projection of charge hose low for gaugemanifold Then connect the projection of charge hose center for gaugemanifold into vacuum pump l Open the handle at low in gaugemanifold operate vacuum pump If the scale moves of gause low reach vacuum condition in a moment check O again y Vacuumize for over 15min And check the level gauge which should read 0 1 MPa 76 cm Hg at low pressure side After the completion of vacuumizing close the handle Lo in gaugemanifold and stop the operation of the vacuum pump Check the condition of the scale and hold it for 1 2min If the scale moves back in spite of tightening make C flaring work again t
16. materia EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS CE All the products are in conformity with the following European provision Low Voltage Directive 73 23 EEC Low Voltage Directive 2006 95 EC Electromagnetic CompatibilitY 89 336 EEC Electromagnetic CompatibilitY 2004 108 EC ROHS The products are fulfilled with the requirements in the directive 2002 95 EEC of the European parliament and of the council on the Restriction of the use of Certain Haz ardous Substances in Electrical and Electronic Equipment EU RoHS Directive WEEE In accordance with the directive 2002 96 CE of the European parliament herewith we inform the consumer about the disposal requirements of the electrical and electronic products DISPOSAL REQUIREMENTS Your air conditioning product is marked with this sym bol This means that electrical and electronic products shall not be mixed with unsorted household waste Do not try to dismantle the system yourself the dis mantling of the air conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation Air conditioners must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed of correctly you will help to prevent potential negative consequences for the environment and human health Please contact the
17. on el resto de resi duos dom sticos no clasificados No intente desmontar el sistema usted mismo El des mantelamiento del acondicionador de aire as como el tratamiento del refrigerante aceite y otros compo nentes debe ser efectuado por un instalador compe tente de acuerdo con las normas locales y nacionales aplicables Los acon dicionadores de aire deben ser tratados en instalaciones especializadas para su reutilizaci n reciclaje y recuperaci n Al asegurarse de desechar este pro ducto de la forma correcta esta contribuyendo a evitar posibles consecuen cias negativas para el entorno y para la salud de las personas Contacte por favor con el instalador o con las autoridades locales para obtener m s infor maci n Las pilas del control remoto deben extraerse y eliminarse por sepa rado y de acuerdo con la normativa local y nacional aplicable Haier AIR CONDITIONERS Haier Industrial Park No 1 Haier Road Qingdao P R China Contains fluorinated greenhouse gases covered by the Kyoto Protocol A Q INFORMAZIONI IMPORTANTI SUL REFRIGERANTE UTILIZZATO Questo prodotto contiene gas fluorurati ad effetto serra inclusi nel Protocollo di Kyoto Non liberare tali gas nell atmosfera Tipo di refrigerante R410A Valore GWP 1975 GWP potenziale di riscaldamento globale Compilare con inchiostro indelebile e la carica di refrigerante di fabbrica del prodotto e2 la quantit di refrig
18. rait s dans un centre sp cialis dans la r utilisation le recyclage et la valo risation des mat riaux L limination correcte de ces appareils permet d vi ter les effets nocifs sur l environnement et la sant humaine Pour plus de renseignements contacter l installateur ou les autorit s locales Les piles doi vent tre retir es de la t l commande et limin es s par ment conform ment a la l gislation locale et nationale en vigueur en la mati re Haier AIR CONDITIONERS Haier Industrial Park No 1 Haier Road Qingdao P R China CONFORMIDAD EUROPEA DE LAS REGULACIONES PARA LOS MODELOS CE Todos los productos estan en conformidad con las siguientes Normativas Europeas Bajo Voltaje directiva 73 23 EEC Bajo Voltaje directiva 2006 95 EC Compatibilidad electromagn tica 89 336 EEC Compatibilidad electromagn tica 2004 108 EC ROHS Los productos cumplen los requisitos de la directiva 2002 95 EEC del parla mento Europeo y el consejo regulador Del uso de materiales peligrosos en equipamientos el ctricos Y electr nicos EU RoHS Directiva WEEE De acuerdo con la directiva 2002 96 CE del parlamento Europeo Informa mos al consumidor acerca del reciclage de los productos Electr nicos y el ctricos REQUISITOS PARA LA ELIMINACI N Su acondicionador de aire est marcado con este s mbolo Esto significa que los productos el ctricos y electr nicos no deben mezclarse c
19. to be fixed against the wall then temporarily fasten the plate with one steel nail 2 Make sure once more the proper level of the plate by hanging a thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 Find the wall hole location A using a measuring tape A 80mm When the mounting plate is fixed side bar and lintel e Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar e Refer to the previous article When the mounting plate is first fixed for the position of wall hole 2 Making a Hole on the Wall and Fitting the Piping Hole Cover e Make a hole of 70 mm in diameter Outdoor side slightly descending to outside the wall Wall hol D all hole Thickness Install piping hole cover and seal it at wall off with putty after installation 70mm Section of wall hole Piping hole pipe 3 Installation of the Indoor Unit Drawing of pipe Rear piping e Draw pipes and the drain hose then fasten them with the adhesive tape Left Left rear piping e In case of left side piping cut away with a nipper the lid for left piping e In case of left rear piping bend the pipes according to the piping direction to the mark of hole for left rear piping which is marked on heat insulation materials Indoor unit 1 Insert the
20. ugh space around Refer in the above figure to drawings e Place where the distance of more than Im from televisions radios wireless apparatuses and fluorescent lamps can be left e In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Power Source e Before inserting power plug into receptacle check the voltage without fail The power source is the same as the corresponding name plate O Install an exclusive branch circuit of the power e A receptacle shall be set up in a distance where the power cable can be reached Do not extend the cable by cutting it Selection of pipe e To this unit both liquid and gas pipes shall be insulated HSU HSU 12HVB03 R2 D as they become low temperature in operation HSU OZHVATOS R b HSU 18HV03 R2 DB HSU 22HV03 R2 DB HSU 08 VOS HALO HSU 12HV03 R2 DB HSU 18HVA103 R2 DB HSU 22HVA103 R2 DB HVA103 R2 Use optional parts for piping set or pipes covered with HSU 12HVA103 R2 equivalent insulation material Liquid pipe 6 35mm 1 4 6 35mm 1 4 The thickness of the pipe must be 0 8 mm at least DB DB Gas pipe 9 52mm 3 8 12 7mm 1 2 Indoor unit 1 Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1 Carry out based on the neighboring pillars or lintels a proper leveling for the plate