Installation Manual SV60 XXX

image

Contents

1. component voltage ratings conductor current ratings fuse sizes and size of controls connected to the PV output A PV module can produce more current and or voltage than reported at STC Sunny and cool weather and reflection from snow or water can increase current and power output List of applicable series of solar modules Polycrystalline SV72 SV60 SV54 SV48 SV36 V72 D SV60 D SV54 D 5 48 D SV36 D YYY family YYY family YYY family YYY family YYY family YYY family YYY family YYY family YYY family YYY family SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Monocrystalline SV72 E SV60 E SV54 E SV48 E SV36 E SV36 5 E SV72 ED SV60 ED SV54 ED SV48 ED SV36 ED SV36 5 ED Page 10 of 10 YYY family YYY family YYY family YYY family YYY family YYY family YYY family YYY family YYY family YYY family YYY family YYY family Rev 5
2. the same type of modules in combined source circuit 4 1 General Wiring SOLVIS recommends that all wiring be double insulated with a minimum rating of 90 C All wiring should use flexible copper Cu conductors Minimum size should be determined by the applicable codes We recommend a size not less than 4 mm The insulation type should be appropriate for the type of installation method used and must meet IEC 61730 and Safety Class Il requirements 4 2 Grounding All module frames and mounting racks must be properly grounded in accordance with appropriate respective national electrical code Proper grounding is achieved by bonding the module frames and all metallic structural members together continuously using a suitable grounding conductor Grounding conductor or strap may be copper copper alloy or other material acceptable for use as an electrical conductor per respective National Electrical Codes The grounding conductor must then make a connection to earth using a suitable earth ground electrode Aluminium frame HEX unit to 16 cable Wire bolt and slot ounting wash hex nut Figure 5 Tyco grounding bolt Important For optimal performance SOLVIS modules must be used in configurations with galvanic insulated inverters where the positive polarity of the PV array is connected to ground protected by a fuse Failure to comply with this requirement can reduce the performance of the system 4 3 Series Connect
3. the surface of the glass grains of sand glass splinters iron oxides etc Make sure that cloths brushes and other tools are clean and in good conditions at all times during cleaning Abrasive powders razor blades scrub sponges and pads must not be used on solar glasses Use of such materials will invalidate the product warranty Modules that are mounted flat 0 tilt angle should be cleaned more often as they will not self clean as effectively as modules mounted at a 15 tilt or greater We recommend that PV modules are mounted at a minimum tilt angle of 6 with respect to the horizon in order to facilitate the self cleaning of their front glass from dirt during ordinary raining SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Page 9 of 10 Rev 5 SOLIS Installation Manual and Safety Instructions 6 Specifications Module electrical ratings are measured under Standard Test Conditions STC of 1000 W m irradiance with AM 1 5 spectrum and cell temperature of 25 C Electrical characteristics for specific SOLVIS PV modules are located on the product label and product datasheet Under normal conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at standard test conditions Accordingly the values of Isc and Voc marked on this module should be multiplied by a factor of 1 25 when determining
4. 65 0015 INSTALLATION MANUAL AND SAFETY INSTRUCTIONS Rev 5 SOLVIS PHOTOVOLTAIC MODULES FAMILY D 6 2243733 018 80258164780 SOLVIS Installation Manual and Safety Instructions COMtentS siiri ee alal ai 1 de 40 30 513 senne TE 9 1 1 1 Disclaimer of fabio 1 1 2 International Electrotechnical Commission IEC Listing Information 1 1 3 Limited Warranty acco 1 1 3 1 Limited Product Warranty Ten 10 Year Repair Replacement or Refund PER 1 1 3 2 Limited Power Warranty 1 1 3 3 Exclusions and IMIRIONSaliibalababaslesslo 2 1 3 4 Limitation of Warranty 2 1 3 5 Obtaining Warranty Performance i 3 2 General sale culi 4 2 1 Safety Precautions seo 4 2 2 Packing removal and temporary storage nnn 4 St SAI 5 dl Seen 5 3 2 Instalator suerinensis nesini 5 33 Mod le an a AAA 5 3 3 1 Site Considerations 5 3 3 2 Mounting Configurallofiszssssze ardea dieta lead 5 dala 8 4 1 GENIALI AA AIA ATA ADI ARONA TARA ARDA 8 42 Ground eraclito aiar 8 4 3 Series COMISO 8 4 4 Parallel Conneciioni sarei 8 5 MANIA 9 6 SSDS CIIGATOINS io AAA ARA 10 Table of Contents SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this man
5. d present a safety hazard modules should not be mounted in manner that the front top glass faces downward e g on a tracking structure that positions the module with the junction box facing skyward during sleep mode Clearance between the module frames and structure or ground is required to prevent wiring damage and allow air to circulate behind the module SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Page 5 of 10 Rev 5 SOLVIS Installation Manual and Safety Instructions When installed on a roof the module shall be mounted over a fire resistant roof covering rated for the application The module is only IEC listed for use when its factory frame is fully intact Do not remove or alter the module frame Creating additional mounting holes may damage the module and reduce the strength of the frame Modules may be mounted using the following methods only 1 Frame Holes Secure the module to the structure using the factory mounting holes Four M6 1 4 stainless steel bolts with nuts washers and lock washers are recommended per module Figure 1 PV module Te Aluminum Frame M6 Stainless screw Flat Stainless Washer TZ HEX Stainless Nut with washer Figure 1 Screw fitting for illustration only Spring Stainless Washer 2 Pressure Clamps or Clips Mount the module with the clips on the side frame of the module Th
6. der normal application installation and use and service conditions If the PV modules fail to conform to this warranty then for a period ending ten 10 years from date of delivery to the original end customer the Customer SOLVIS will at its option either repair or replace the product or refund the purchase price as paid by the Costumer The repair replacement or refund remedy shall be the sole and exclusive remedy provided under the Limited Product Warranty and shall not extended beyond the ten 10 year period set forth herein This Limited Product Warranty does not warrant a specific power output which shall be exclusively covered under clause 2 hereinafter Limited Power Warranty 1 3 2 Limited Power Warranty e SOLVIS additionally warrants if within twelve 12 years from date of delivery to the Costumer any PV modules exhibit a power output less than 90 of the Minimum Peak Power as specified at the date of delivery in SOLVIS Product datasheet provided that such loss in power is determined by SOLVIS at its sole and absolute discretion to be due to defects in material or workmanship SOLVIS will replace such loss in power by either providing to the Costumer additional PV modules to make up such loss in power or by providing monetary compensation equivalent to the cost of additional PV modules at the option of SOLVIS Minimum Peak Power if not expressed directly in SOLVIS Product Datasheet is defined as Nominal Power minus Power Tole
7. e side frames are attached to the longer sides of the module The centerline of the clips should be 1 4 1 8 from the end of the module length Installers should ensure the clamps are of sufficient strength to allow for the maximum design pressure of the module Figure 2 Clips and clamps are not provided by SOLVIS Figure 2 Clamp fitting for illustration only Figure 3 Landscape and portrait orientation installation SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Page 6 of 10 Rev 5 SOLVIS Installation Manual and Safety Instructions 3 End Mount End mounting is the capture mounting of the length of the module s end frame to a supporting rail The end frames are on the shorter sides of the module Refer to the products respective datasheet for dimensions and mounting holes position Figure 4 Mounting grounding and drainage holes positions SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Page 7 of 10 Rev 5 SOLVIS Installation Manual and Safety Instructions 4 Wiring To achieve the desired electrical output modules can be connected in series and or parallel as long as certain conditions are met Use only
8. her obligations or liabilities on the part of SOLVIS unless such other warranties obligations or liabilities are expressly agreed to in writing signed and approved by SOLVIS SOLVIS shall have no responsibility or liability whatsoever for damage or injury to persons or property or for other loss or injury resulting from any cause whatsoever arising out of or related to the product including without limitation any defects in the module or form use or installation Under no circumstances shall SOLVIS be liable for incidental consequential or special damages howsoever caused Loss of use loss of profits loss of production loss of revenues are therefore specifically but without limitation excluded e SOLVIS aggregate liability if any in damages or otherwise shall not exceed the purchase price paid to SOLVIS by the Customer for the unit of product or service furnished or to be furnished as the case may be which gave rise to the warranty claim e In jurisdiction not allowing limitations on implied warranties or the exclusion of damages the above limitations or exclusions may not be applicable SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Page 2 of 10 Rev 5 SOLVIS Installation Manual and Safety Instructions 1 3 5 Obtaining Warranty Performance If you feel you have a justified claim covered by this Limited Warranty immediately notify the a Installer
9. ion Modules may be wired in series to produce the desired voltage output The maximum number of modules connected in series are defined by sum of single module Voc 1 25 up to the maximum system voltage Overcurrent protection rating is calculated by module Isc 1 56 Do not exceed the maximum system voltage 4 4 Parallel Connection Modules may be combined in parallel to produce the desired current output The maximum number of modules in parallel connection depends on inverter s capacity Every series string or module must be fused prior to combining with other strings Bypass diodes are factory installed in the modules Please refer to applicable regional and local codes and also inverter producer for additional fusing requirements and limitations on the maximum number of modules in parallel SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Page 8 of 10 Rev 5 SOLVIS Installation Manual and Safety Instructions 5 Maintenance Inspect all modules annually for safe electrical connections sound mechanical connection and freedom from corrosion Glass of PV modules can be washed with plenty of clean water and Soft paper towels soft brushes soft cloths or tissues Once cleaned the glass should be rinsed with clean water and carefully wipe with a soft cloth Before washing the glass with AR coating make sure to remove all residues and particles that could scratch
10. ion within the following maximum and minimum operating temperatures Maximum Operating Temperature 85 Minimum Operating Temperature 40 C Care should be taken to provide adequate ventilation behind the modules especially in hot environments Design Strength SOLVIS modules are designed to meet a maximum positive or upward e g wind and negative or downward e g static load load of 2400 Pa Pascal 2400 kg m and snow load of 5400 Pa when mounted in one of the mounting configurations specified in section 3 3 2 When mounting modules in snow prone or high wind environments special care should be taken to mount the modules in a manner that provides sufficient design strength while meeting local code requirements Excluded Operating Environments Certain operating environments are not recommended for specific SOLVIS modules and are excluded from the SOLVIS Limited Warranty for these modules 3 3 2 Mounting Configurations Modules may be mounted at any angle from horizontal to vertical Select the appropriate orientation to maximize sunlight exposure Specific information on module dimension and the location of mounting and grounding holes is provided below Figure 4 We recommend that PV modules are mounted at a minimum tilt angle of 6 with respect to the horizon in order to facilitate the self cleaning of their front glass from dirt during ordinary raining In order to prevent water from entering the junction box which coul
11. ng but not limited to installation application or removal by any party other than SOLVIS authorized dealer non observance of SOLVIS installation manual users and or maintenance instructions repair or modifications by someone other than an approved service technician of SOLVIS power failure surges lighting flood fire accidental breakage or other events outside SOLVIS control Cosmetic defects originating from normal wear and tear of PV module materials while in use PV modules installed in locations which in SOLVIS absolute judgment may be subject to direct contact with salt water e The Limited Warranties do not cover any transportation costs for return of the PV modules or for reshipment of any repaired or replaced PV modules or cost associated with installation removal or reinstallation of the PV modules e When used on a mobile platform of any type the Limited Power Warranty applying to any of the PV modules shall be limited to twelve 12 years as per provisions of clause 1 3 2 hereof e Warranty claims will not apply if the type or serial number of the PV modules is altered removed or made illegible 1 3 4 Limitation of Warranty Scope e Subject to the limitations under applicable law the limited warranties set forth herein are expressly in lieu of and exclude all other express or implied warranties including but not limited to warranties of merchantability and of fitness for particular purpose use or application and all ot
12. rance SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Page 1 of 10 Rev 5 SOLVIS Installation Manual and Safety Instructions e SOLVIS additionally warrants if within twenty five 25 years from date of delivery to the Costumer any PV modules exhibit a power output less than 80 of the Minimum Peak Power as specified at the date of delivery in SOLVIS Product datasheet provided that such loss in power is determined by SOLVIS at its sole and absolute discretion to be due to defects in material or workmanship SOLVIS will replace such loss in power by either providing to the Costumer additional PV modules to make up such loss in power or by providing monetary compensation equivalent to the cost of additional PV modules at the option of SOLVIS Minimum Peak Power if not expressed directly in SOLVIS Product Datasheet is defined as Nominal Power minus Power Tolerance 1 3 3 Exclusions and limitations e Warranty claims must in any event be filed within the applicable Warranty period e Warranty claims may only be made by or on the behalf of the original end customer or a person to whom title has been transferred for the PV modules e The Limited Warranties do not apply to any of the following PV modules which in SOLVIS absolute judgment have been subjected to misuse abuse neglect or accident alteration improper installation application or removal includi
13. structions for later reference in an easy reachable place 2 2 Packing removal and temporary storage e Modules must be stored in dry and ventilated spaces e Leave modules unpacked in their original packing until you are ready to install them e Carry the modules with both hands e Do not put weight on the modules e Do not remove any identification labels from the modules e If storing uninstalled modules outdoors for any period of time always cover the modules and ensure that the glass faces down to stop water from collecting inside the module and on top of the glass SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Page 4 of 10 Rev 5 SOLVIS Installation Manual and Safety Instructions 3 Installation 3 1 General Before install and operate this manual must be well understood 3 2 Notes on Installation A gap between PV module frame and installation object is necessary for cooling air circulation Do not seal this gap The recommended standoff height is minimum 10 cm 4 inch 3 3 Module Mounting SOLVIS Limited Warranty for PV Modules is contingent upon modules being mounted in accordance with the requirements described in this section 3 3 1 Site Considerations SOLVIS modules should be mounted in locations that meet the following requirements Operating Temperature All SOLVIS modules must be mounted in environments that ensure operat
14. t try to disassemble the module e Do not use modules that are damaged e g front glass is broken or back sheet is torn e Do not open the junction box on the back side of the module e Contact your module supplier if maintenance is necessary e Installation should be performed only by authorized personnel e Use only equipment connectors wiring and supporting constructions designed for use in photovoltaic systems e Remove all metallic jewelry prior to installing this product to reduce the chance of accidental exposure to live circuits e Use insulated installation tools to reduce risk of electrical shock e Do not stand on drop scratch or allow objects to fall on modules e To avoid damage to the backsheet do not scratch or hit the backsheet e Do not drill holes in the frame as this can compromise the frame strength and cause corrosion of the frame e Do not scratch the frame as this may remove the anodized coating of the frame and cause corrosion of the frame e Do not use junction box or connecting wires for transportation help or for holding the module e Do not treat the back side of modules with paint glue or sharp objects e If the front glass is broken or the back sheet is torn contact with any module surface or module frame can cause electric shock e Do not install or handle the modules when they are wet or during periods of high wind e SOLVIS SV60 modules have been qualified for Application Class A e Save these in
15. ual may be changed without prior notice Rev 5 SOLVIS Installation Manual and Safety Instructions 1 Introduction This manual provides information for SOLVIS photovoltaic PV modules Serial number 1YYMM00001 99999 Ex 1130100004 e 1 production site SOLVIS factory Production year and month e 00001 99999 Production number This document is applicable to SOLVIS polycrystalline and monocrystalline photovoltaic modules 1 1 Disclaimer of Liability The installation techniques handling and use of this product are beyond company control Therefore SOLVIS does not assume responsibility for loss damage or expense resulting from improper installation handling or use 1 2 International Electrotechnical Commission IEC Listing Information This product meets all requirements listed by IEC 61215 edition 2 for terrestrial PV modules The IEC standard covers flat plate PV modules and panels intended for installation on buildings and those intended to be freestanding This product is not intended for use where artificially concentrated sunlight is applied to the module 1 3 Limited Warranty 1 3 1 Limited Product Warranty Ten 10 Year Repair Replacement or Refund Remedy SOLVIS d o o Brezje bb P O B 113 HR 42000 Vara din Croatia SOLVIS warrants that for ten 10 years from the date of delivery its Photovoltaic modules PV modules shall be free from defects in materials and workmanship un
16. who sold the PV modules or b any authorized SOLVIS distributor of the claim in writing or c send such notification to SOLVIS directly In addition please enclose evidence of the date of delivery of the PV module If applicable your installer or distributor will give advice on handling the claim If further assistance is required please write to SOLVIS for instructions The return of any PV modules will not be accepted unless prior written authorization has been given by SOLVIS SOLVIS is a trademark of SOLVIS d o o Vara din Croatia The content of this manual may be changed without prior notice Page 3 of 10 Rev 5 SOLVIS Installation Manual and Safety Instructions 2 General Safety 2 1 Safety Precautions Danger PV modules are sources of voltage when exposed to light Module interconnects pass direct current DC when the module is under load Do not connect or disconnect modules when they are under load Direct current can arc across gaps and may cause injury or death if improper connection or disconnection is made or if contact is made with module leads that are frayed or torn Before installing this device read all safety instructions in this manual e Cover all modules in the PV array with an opaque material before making or breaking electrical connections e installations must be performed in compliance with all applicable regional and local codes e Do not attempt to repair any part of the module e Do no