1. UM aAxcs LL 0 CANICOM User s guide 500 Pro DECLARATION CE DE CONFORMITE EC DECLARATION OF CONFORMITY Directive R amp TTE 1999 5 CE NUM AXES d clare que declares that le collier d ducation the training collar CANICOM 500 PRO satisfait a toutes les dispositions de la Directive N 1999 5 CE du 07 04 99 du Conseil Europ en complies to all dispositions of the European Council Directives below N 1999 5 CE et est conforme aux normes suivantes and complies with standards below ETSI EN 300 220 CE NUM AXES 745 rue de la Bergeresse Z A C des Aulnaies BP 30157 45161 OLIVET CEDEX FRANCE T l 33 0 2 38 63 36 56 Fax 33 0 2 38 63 31 00 WARNING Any person with individual device for cardiac assistance pacemaker defibrillator must take precautions when they use CANICOM 500 PRO This device emits some static magnetic fields a magnet is located in the remote control Frequency 869 Mhz at 250 mW The device complies with the European Standard ETSI EN 300 220 Thank you for choosing a NUM AXES product Before using your CANICOM 500 PRO please read the instructions in this guide carefully and keep it for future reference Before using CANICOM 500 PRO we advise you to have your dog checked by your vet to ensure it is fit to wear a collar Check your dog s neck regularly the repeated rubbing of the contact points against the animal s skin may cause irritation If this hap
2. s guide CANICOM 500 PRO indice A 2 12 e First use from new Fitting the battery in the CANICOM receiver collar Unscrew the 4 screws of the top of CANICOM Insert the battery 3 Volt Lithium CR 2 paying attention to follow polarity indicated on the battery housing ref Diagram 4 A beep sound low pitch is emitted indicating the correct installation of the battery If you do not hear any beep sound after inserting the battery immediately remove it from its housing Check the polarity before trying again Before putting the lid back in place check that the rubber seal is in its groove Retighten moderately the 4 screws Polarity of the battery Polarity of the battery Seal Diagram 4 Activate deactivate the remote control Remote control is supplied with battery fitted Activate press for 1 second the On Off red button located on the side of the remote control ref Diagram 1 Indications appear on the LCD screen Deactivate press for 1 second the On Off red button located on the side of the remote control ref Diagram 1 The LCD screen is Off To increase the battery life of the remote control and receiver collar you should deactivate the units if you are not using them for a long period Activate deactivate the CANICOM training collar A magnet located in the remote control is used to switch the CANICOM receiver collar On or Off Activate move the remote cont
3. and the groove must be clean too in order to avoid any problem with the waterproof function 8 Firmly screw up the 4 screws in order to maintain your product s water tightness aid NOTE if the 5 seconds have passed before having time to code the collar or if the code is badly recorded in the collar you can start again by pressing the push button The coding system located in the collar memorizes up to 9 different codes This memory can become saturated if you have encoded your collar with several remote controls In this case the red indicator LED flashes after you press the push button to code In order to erase this memory press continuously on the push button until the LED is Off the memory is empty and you can recode your collar with a remote control _ Diagram 7 Push button for coding Red indicator LED For further information regarding the CANIBEEP RADIO PRO beeper collar operation settings cautions for use technical specifications please read the user s guide provided with the collar e How to use the remote control The CANICOM 500 PRO remote control is designed to operate with one CANICOM training collar and or one yellow CANIBEEP RADIO PRO beeper collar How to use the remote control with a CANICOM receiver collar black button ad beeper If you press the black beeper button ad on the remote control the receiver collar will emit sound signals There is no time limit for this
4. flash stimulation Both functions are extremely interesting and useful since they can be adapted to any dog and any situation continuous stimulation Should be typically used for training at a location that is familiar to the dog at the beginning Because the stimulation is continuous use the lowest intensity and take advantage of the length of the stimulation rather than of the intensity so your dog has time to understand flash stimulation Use this function to correct your dog A low stimulation will attract its attention it will feel something unpleasant at the precise moment it is behaving badly e Cautions for use The CANICOM receiver collar is totally waterproof Your dog can swim in water In order to maintain water tightness we recommend the replacement of the seal located in the receiver collar every year The remote control is shower proof only it is only designed to remain a short time in the rain Put it in a dry place as soon as possible If the remote control falls into the water it could be damaged in an irreversible way Your dog should not wear a tag metallic collar or any other kind of collar together with the training collar CANICOM Avoid placing the remote control close to objects sensitive to magnetic fields which could be irreversibly damaged Do not place or keep the unit in places exposed to high temperatures Remove the battery from the receiver collar and the remote control
5. D ee ee eee 11 GuUarahtes COnultlS RS arca 11 DAS DAS PP RE R 11 Collection and recycling of your device at the end Of its life oocccccccccccccncccccnnncncncnnnnnnnnnnn nana naar nn rra 11 e Contents of the product CANICOM 500 PRO CANICOM receiver collar equipped with short contact points 3 V Lithium CR2 battery for the collar CANICOM 500 PRO remote control equipped with a 3 V Lithium CR2 battery screwdriver 2 contact points neon test lamp short or long pair of long contact points a eu Strap Red mark area where the uN this users guide On Off switch magnet is located e Description of the product On Off button LCD screen retro lightning Booster button Y On Off indicator 200 PRO LCD AS oem radio reception indicator Continuous stimulations limited to 8 seconds battery level indicator Stimulation level adjustment RECEIVER COLLAR Flash stimulations Diagram 2 shorter than 1 second Beeper P ad Buttons designed to operate a Battery level CANIBEEP RADIO PRO collar FR ME indicator Magnet position indicator Radio this magnet allows you to Locate the dog transmission switch On Off the training or indicator beeper collar and to re code the training Deactivate beeper collar or beeper collar with the temporarily or completely Enero COS Stimulation level indicator REMOTE CONTROL from 1 to 15 Diagram 1 LCD SCREEN Diagram 3 User
6. flashes slow green weak battery flashes quickly red Replace it with a new 3 V Lithium CR2 battery See First use from new Fitting the battery in the CANICOM receiver collar Check the receiver collar operates correctly NUM AXES advises to use the same type and same brand of batteries as those supplied in your new purchased product Other brands of batteries may not operate or may not be completely compatible with your product You can purchase the suitable batteries from NUM AXES or from your distributor e Changing the contact points Two different series of contact points are supplied The length of the contact points must be sufficient to have proper contact with the dog s skin enabling the device to operate correctly If you have a long haired dog and the short contact points fitted to the collar in the factory are inadequate remove and replace them with the long ones supplied with the kit Carefully tighten them manually do not use a key e How to check that your CANICOM 500 PRO is functioning properly You can check that your CANICOM 500 PRO is operating correctly at any time Before doing so make sure that the receiver collar is turned Off indicator light off You can place the neon test lamp in contact with each of the contact points by unscrewing them then by screwing them up in order to grip wires of the lamp under the contact points Turn On the remote control and receiver collar Pr
7. range Ref Re coding procedure Coding of the remote control and CANIBEEP RADIO PRO beeper collar The synchronization of the remote control with your CANIBEEP RADIO PRO collar is necessary only at the first use of the collar Coding enables the remote control and the collar to work together IMPORTANT before beginning the coding make sure no other person is using his CANICOM 500 PRO or other products from the NUM AXES range close by your receiver collar could accidentally record the code of his remote control CODING PROCEDURE FOR THE 1 USE 1 To begin the coding procedure your remote control and CANIBEEP RADIO PRO collar must be switched On 2 Unscrew the 4 screws of the top of CANIBEEP RADIO PRO collar with a Philips screwdriver 3 Briefly press on the push button located in the case of the collar ref Diagram 7 a red indicator LED will show Once the red LED light shows you have only 5 seconds to synchronize the remote control and the collar 4 Move your remote control away from the collar pressing continuously on the yellow button of the remote control until you see the red indicator LED going Off The collar emits a beep sound the collar has correctly recorded the code of the remote control Check the coding of your collar by testing the operation of the CANIBEEP RADIO PRO Once you have finished the coding put the top back in place paying attention to the rubber seal It must be clean well positioned in its groove
8. unit if you are not using it for a long period e Guarantee NUM AXES guarantees the product against production defects for 2 years after purchase All postage and packing charges will be the purchaser s sole responsibility Guarantee conditions 1 The guarantee will be valid only if the proof of purchase invoice or sales receipt without cancellation is submitted to the distributor or to NUM AXES The guarantee is limited to the original purchaser 2 This guarantee does not cover the following changing the batteries changing the strap direct or indirect risks incurred when sending the article back to the distributor or NUM AXES damage to the article caused by negligence or incorrect use ex bites breakage cracking use contrary to the instructions or not envisioned therein repairs performed by unauthorized persons loss or theft If the product is found to be defective NUM AXES will either decide to repair or to replace it No claim may be advanced against NUM AXES particularly in relation to incorrect use or breakdown NUM AXES reserves the right to modify the characteristics of its products with a view to making technical improvements or to comply with new regulations 6 The information contained in this guide may be subject to amendment without prior notice 7 Photos and drawings are not contractual AS e Spare parts You can purchase spare parts batteries strap from your supplier at any ti
9. d while the stimulations are being sent If you press the C button for more than 8 seconds the collar will automatically go into safety mode for a few seconds before restarting itself normally Note beep sounds can be associated to the stimulations by pressing first the C button and then the black beeper button LC button booster Press the Booster button to stop your dog instantaneously You can choose the stimulation level you think to be the best for an immediate effect As a result you do not need to press the button Those stimulations are transmitted by the two contact points located on the collar for as long as the button is pressed but no more than 8 seconds maximum If you press the Booster button for more than 8 seconds the collar will automatically go into safety mode for a few seconds before restarting itself normally Configuration of the Booster button select the stimulation level 01 press the button until the stimulation level flashes on the LCD screen press the or button to modify the stimulation level press the Booster button to confirm the level selected e O and O buttons stimulations level control buttons Use the O and O buttons for rapid adjustment of the stimulation level of the receiver collar 15 levels are available Level 1 very weak stimulations Level 15 strong stimulations Always start with the lowest level of stimulation User s guide CANICOM 500 PRO in
10. dice A 6 12 Retro lightning of the LCD screen You can light the LCD screen for approximately 6 seconds by pressing briefly the On Off red button approx Ya second How to use the remote control with a CANIBEEP RADIO PRO beeper collar From the remote control you can Locate the dog briefly or continuously press the yellow button Q on the remote control to activate a beep sound on the collar whenever your dog is pointing or moving Deactivate temporarily the collar briefly press 1 to 2 seconds the yellow button OO ine collar is in stand by it is temporarily switched Off no beep sounds whether the dog is pointing or moving The red indicator LED is still flashing to indicate that the collar is not definitely turned Off Reactivate the collar after it was temporarily deactivated if your collar has been temporarily deactivated press the yellow button you reactivate your collar on the last selected mode Completely switch off the collar if you continuously press the yellow button 60 approx 5 seconds you will completely switch Off your collar Warning you will not be able to remotely reactivate it For further information regarding the CANIBEEP RADIO PRO beeper collar operation settings cautions for use technical specifications please read the user s guide provided with the collar e Checking replacing battery of remote control Performance radio range of the remote control may deteriorate as batte
11. e remote control towards the collar so that the magnet position indicator on the remote control comes into contact with the area indicated on the back of the collar hold for at least 1 second ref Diagram 6 The collar will emit one low pitch beep sound and the red indicator light will flash briefly indicating the CANIBEEP RADIO PRO is Off Diagram 6 Activate deactivate a CANIBEEP RADIO PRO beeper collar with a CANICOM 500 PRO remote control Place these two areas together for 1 second To increase the battery life of the remote control and receiver collar you should deactivate the units if you are not using them for a long period For further information regarding the CANIBEEP RADIO PRO beeper collar operation settings cautions for use technical specifications please read the user s guide provided with the collar Coding of the remote control and CANICOM receiver collar Each remote control has its own individual radio operator code The coding of the remote control with the receiver collar enables the two units to work together IMPORTANT before beginning the coding first use of receiver collar or re coding make sure no other person is using his CANICOM 500 PRO or other products from the NUM AXES range close by your receiver collar could accidentally record the code of his remote control If that occurs re code the remote control with your receiver collar CODING PROCEDURE FOR THE 1 USE 1 2 Activa
12. ess the F or C button and modify the level of intensity of the stimulations the test lamp will come on with more or less intensity e Getting the best results The training instructions you send to your dog are sent from the remote control to the receiver collar by radio waves These radio waves are sensitive and the range reaches approximately 500 meters depending on geography and environment The performances of your CANICOM 500 PRO will be optimal if you follow these recommendations To obtain a good radio range do not cover the antenna when you hold the remote control in your hand The position of the receiver collar around the neck of your dog should be in the following way the On Off indicator is visible and is not in contact with the breast of the dog Check the batteries remote control and receiver collar before using the unit and replace them as soon as the level of load is weak The performances of the batteries decrease slightly in temperatures lower than 0 C If possible keep the remote control warm e g inside a pocket before using it e Fitting the CANICOM collar The strap must be adjusted so that the contact points are in contact with the skin of the dog If the strap ts too loose the collar is likely to move and repeated friction can irritate the skin of your dog Furthermore it will not function correctly If the collar is too tight the dog will have breathing difficulties Do not leave the c
13. function the beeper will continue to sound for as long as the button is pressed User s guide CANICOM 500 PRO indice A 5 12 A transmission symbol will appear on the LCD screen of the remote control The indicator light on the collar goes from flashing green to permanent green for as long as the button is pressed It is up to you to use the beeper button depending on the way you want to train your dog With the beeper button you can send a sound to your dog when it is disobedient draw its attention It s very important to always use the beeper in the same way in order not to disturb your dog e F button flash stimulations Press the F button to send a warning to your dog using flash stimulations transmitted by the two contact points located on the receiver collar for a defined length of time of less than one second A transmission symbol will appear on the LCD screen of the remote control The indicator light on the collar goes from flashing green to permanent red while the stimulations are being sent e button continuous stimulations Press the C button to send a warning to your dog using continuous stimulations transmitted by the two contact points located on the receiver collar this will last for as long as the button is pressed but limited to 8 seconds maximum A transmission symbol will appear on the LCD screen of the remote control The indicator light on the collar goes from flashing green to permanent re
14. if you are not using the appliance for 3 months or more The collar will memorize the configuration chosen coding It is necessary to replace the batteries every two years even if the unit has not been used for long periods Never leave a discharged battery in the unit leakage could damage your CANICOM 500 PRO Keep your CANICOM 500 PRO unit out of reach of children It is not a toy for you or your children e Maintenance Avoid cleaning the unit with volatile liquids such as solvents or cleaning fluids Use a soft cloth and neutral detergent In order to maintain water tightness we recommend the replacement of the seal located in the receiver collar every year User s guide CANICOM 500 PRO indice A 9 12 e Troubleshooting Should your CANICOM 500 PRO stop working or develop a fault first read this guide over then check the batteries and that you are using the product correctly If you encounter any problem re code the receiver collar ref re coding procedure Re initialize the system by removing the battery from its housing then with a metallic tool e g screwdriver scissors touch each of the 2 battery contacts for 2 seconds approximately ref Diagram 9 Insert the battery again one beep is emitted indicating the battery is in correct position Diagram 9 Restart your CANICOM collar using the remote control ae ee j j Reset connect the 2 supports of the battery If the problem persists contac
15. me e Collection and recycling of your device at the end of its life The pictogram EEE which appears on your product means that this one can not be thrown with household refuse You have to bring the device to a collection location suitable for treatment development recycling of electric wastes or bring it back to your distributor Adopting this process you do something for the environment you contribute to the preservation of natural resources and to the protection of human health User s guide CANICOM 500 PRO indice A 11 12 NUM AXES a Y E www humaxes com internationalsales numaxes com www ecma eu com FOR PET PROTECTION User s guide CANICOM 500 PRO indice A 12 12
16. ollar positioned at the same place for long periods i e over 3 hours because this can cause irritations If your dog must wear the collar for long periods regularly change the position on the neck of your dog Never leave the collar more than 8 hours per day on your dog Check your dog s neck regularly If irritations appear remove the collar until all signs of skin irritations have disappeared User s guide CANICOM 500 PRO indice A 8 12 e Starting out with the training collar You can start using the collar with 6 month old puppies that have already received some basic training stay sit or at least no Do not use the collar with dogs that are not in good physical shape i e cardiac problems epilepsy or have behavioural problems Your dog will need to get used to the collar for a few days let the dog wear the collar but do not use it Positive and effective training takes time Do not rush Choose a familiar area a place your dog is used to Define the level of stimulation from which your dog reacts by starting with the level of the lowest intensity and increasing gradually Choose the right moment to press the button at the exact time your dog does something wrong Give your dog plenty of encouragement it will learn faster and its desire to respond will only increase Do not hesitate to contact a professional trainer for any further advice e The difference between continuous and
17. pens remove the collar until all signs of skin irritation have disappeared Start with the lowest level of stimulation and define the level from which your dog reacts by increasing gradually Do not hesitate to contact a professional trainer for any further advice 1 12 Index Page Contents of the product CANICOM 500 PRO nan aa ornato 2 SSD ae AE Proquet tor a ido EE dd A A TAE AEA 2 SE CS SO SW ia 3 HOW tO USE NE remote Control essa 5 Checking replacing battery of remote Control 2223820 nanena A AAA 7 Checking replacing battery of CANICOM receiver collar ins 8 Changing the contact POINTS 288 dd nd in aie esse ina a a aa icicbnn 8 How to check that your CANICOM 500 PRO is functioning properly rss ennnnnne 8 Getting the best results sissies ccavecccccectacetsavertssdersen cies cdeendas ines ties deeesseseiee biases sdesieeae edneeeesscdteatiad eames davsisectasaxes es 8 Fitting tne CANICOM colla SE is cobs tostetecsann cinc aaa en 8 Stareing OuL With ENS training Collar sadacescsensvessedeasesenewssetanddcstdsvevaweianediuedevecsvede ced uedenatsuete tes aneaatensueisncdceesetetamdas 9 The difference between continuous and flash stimulation cece cece ce eeeeeeeeeeeeeeeeeeeeeeeeeaeeeaeaaaeaaaeaaueuaaanananaaags 9 CAUTIOUS OP ea Os a de a Da a as bl ed ees 9 A PS RAS OS EEE ZE 9 zed DIS AOC CIS Pe E ee ee ee oo 10 T pai eciecl else i ONS a O eo ee 10 CANICOM receiver collar battery life cadenas aaa 11 COR
18. rol towards the collar so that the magnet position indicator on the remote control comes into contact with the red mark on the collar hold for 1 second ref Diagram 5 The indicator light on the collar will flash in green indicating the CANICOM receiver is On Deactivate move the remote control towards the collar so that the magnet position indicator on the remote control comes into contact with the red mark on the collar hold for 1 second ref Diagram 5 The indicator light on the collar will flash from green to red and then off the CANICOM receiver is Off Place these two areas together for 1 second Diagram 5 Activate deactivate a CANICOM receiver collar with a CANICOM 500 PRO remote control To increase the battery life of the remote control and receiver collar you should deactivate the units if you are not using them for a long period User s guide CANICOM 500 PRO indice A 3 12 Activate deactivate the CANIBEEP RADIO PRO beeper collar A magnet located in the remote control is used to either switch On Off the CANIBEEP RADIO PRO beeper collar Activate move the remote control towards the collar so that the magnet position indicator on the remote control comes into contact with the area indicated on the back of the collar hold for at least 1 second ref Diagram 6 The collar will emit two low pitch beep sounds and the red indicator light will flash briefly indicating the CANIBEEP RADIO PRO is On Deactivate move th
19. ry becomes weak Be prepared to replace the battery To check the condition of the battery turn On the remote control and look at the battery level indicator on the LCD screen The symbols which appear indicate the following DI Battery fully charged ik Weak battery prepare to replace the battery L___ Dead battery your CANICOM 500 PRO switches to safety mode and the system locks up The battery must be replaced NUM AXES advises to use the same type and same brand of batteries as those supplied in your new purchased product Other brands of batteries may not operate or may not be completely compatible with your product You can purchase the suitable batteries from NUM AXES or from your distributor Rate the old battery with a new one as follows On the back of the remote control unscrew the screw and remove the battery cover Remove the old battery Insert the new battery 3 V Lithium CR2 paying attention to follow polarity indicated on the battery housing ref Diagram 8 Put the battery cover back in place Retighten the screw Check the remote control operates correctly Diagram 8 Replacing battery of CANICOM 500 PRO WARNING Make sure the polarity is correct User s guide CANICOM 500 PRO indice A 7 12 e Checking replacing battery of CANICOM receiver collar To check the condition of the receiver collar battery observe the indicator light located on the front of the receiver collar battery fully charged
20. t your distributor or check out on www numaxes com You can also contact NUM AXES at 33 2 38 63 03 84 or by Email internationalsales numaxes com Depending on the extent of the malfunction you may have to return your product for service and repair For all repairs please supply the following the complete product the proof or purchase invoice or sales receipt If you omit one of these items the After Sales Service will have to invoice you for any repair costs incurred e Technical specifications Remote control CANICOM receiver collar 3 V Lithium CR2 battery 3 V Lithium CR2 battery Battery life Continuous use In stand by Approximately 30 000 triggers Approximately 7 months Continuous use Approximately 2 months Rane approximately soometers Radio operator safety and By microcontroller By microcontroller coding Battery power indicator Indicator on the LCD screen Indicator light Temperature limitations Between 20 C et 40 C Between 20 C et 40 C Dimensions 108 mm x 55 mm x 24 mm 68 mm x 43 mm x 38 mm Weight with the battery 85 g 75 g without strap Collar adjustable to neck sizes from 20 to 50 cm User s guide CANICOM 500 PRO indice A 10 12 e Receiver collar battery life 7 months in stand by for a use of 4 hours a day 2 months in continuous use about 5 000 stimulations of 2 seconds at level 15 To increase the battery life of the receiver collar we recommend you to deactivate the
21. te the remote control press for 1 second the On Off red button located on the side of the remote control Activate the receiver collar move the remote control towards the collar so that the On Off switch magnet comes into contact with the red mark on the collar hold for 1 second ref Diagram 5 Move the remote control away from the receiver collar Press the black beeper button located on the side of the remote control A beep sound is emitted the receiver collar is then synchronized with your remote control RE CODING PROCEDURE for all coding procedures other than the 1 1 Activate the remote control press for 1 second the On Off red button located on the side of the remote control Receiver collar in position deactivate indicator light off move the remote control towards the collar so that the magnet position indicator comes into contact with the red mark on the collar hold for 6 seconds The indicator on the receiver collar lights in fixed green then flashes in red Move the remote control away from the receiver collar Press the black beeper button md located on the side of the remote control A beep sound is emitted the receiver collar is then synchronized with your remote control User s guide CANICOM 500 PRO indice A 4 12 Reprogram a CANICOM receiver collar The CANICOM receiver collar can be re coded indefinitely either with the same remote control or with a new remote control from the CANICOM