1. TEL LINE ETO7 AC DC 10 24V 230V 50Hz Alarm Control Panel O RING TIP Fig No 2 Fig No 3 The system can be installed only in a metal or non flammable plastic box When the metal box is also used as power supply ground transformer it is necessary to ground the box using yellow green colour cable For the connection of ground 230V trans former use 3x0 75 mm2 1 thread double isolated cable The initial winding of the ground transformer must be connected through 0 5A fuse 230V power supply cables cannot be grouped with low voltage cable group For the connection of power supply and output connectors use 1 thread 2x0 75 mm2 cable For the connection of input output connectors use 0 50 mm2 1 thread cable 1 7 Light Emitting Indicators Functionality Connection Strength Indicator To identify connection strength GSM indicator is used To ensure the best quality of the network adjust the position of GSM antenna and find the best possible connection by watching the frequency of indicator blinking GSM indicator blinking Meaning Off No connection Every 3 seconds The connection is not reliable Every second Satisfactory Several times per second Good Indicator is lit Excellent It is recommended to install the antenna remotely from communicator panel Thus you will ensure better quality of audio signal We do not recommend installing the antenna in a metal box It is also used few others indicators device activity in
2. To ensure maximum system operation reliability we recommend do not use prepaid cards If the balance is insufficient the system will not be able to inform users about the alarm IMPORTANT Power supply at Alarm Control Panel must be disconnected before any installation or tuning work Device installation and Pre operation il Fasten the system in the box using fastening holders 2 Place SIM card in the holder but make sure that SIM card PIN code is disabled PIN code can be disabled by putting SIM card into mobile phone and following proper menus SIM card should not have any remaining SMS messages Connect the antenna the device cannot be turned on without antenna 4 Connect the circuit as shown in fig no 2 connect telephone line output of the Alarm Control Panel RING TIP to TEL LINE connectors of communicator ETO7 In this case power supply is usually used as AUX output of Alarm Control Panel 5 When AC power supply ground transformer is used connect according to circuit no 3 In this case you do not need to connect any other power supplies 6 The system should start in less than a minute STATUS indicator should be blinking every five seconds indicating connection to GSM network If the indicator is blinking very frequently i e several times per second it is possible that SIM card is inser ted incorrectly or PIN code request is not disabled
3. connectors DEFAULT connect power supply for 5 seconds disconnect power supply disconnect connectors DEFAULT 3 2 ET07 Configuration Program System configuration is performed by using program software ET07 Configuration Tool that can be downloaded from internet website www eldes It Before connecting the cable to the computer via USB or RS232 type port read ET07 Configuration Tool user manual that can be found in HELP section of the program 3 3 Technical Support Indicator STATUS is off and not blinking no external power supply circuit not properly connected blown fuse no network signal Indicator STATUS is blinking several times per second SIM card is not inserted SIM card PIN code request has not been disabled SIM card not active System does not deliver any SMS messages SIM card account depleted incorrect SMS central number no network signal user telephone number is not programmed in users list user telephone number is indicated improperly read more about it in ETO7 Configuration Tool user manual which can be founf in Help section of the program If your problem could not be fixed by the self guide above please contact your distributor or ELDES technical support by e mail support eldes It More up to date information about your device and other products can be found at the manufacturer s website www eldes lt USER MANUAL ELDES ETO7 V1 0 17 Pagaminta Lietuvoje Made in Lithuania CgenaHo B JIu
4. transmits information from the Alarm Control Panel to the monitoring station via GSM audio connection signal as well as to registered users via SMS message An additional computer program ET07 Configuration Tool is also used for configurations which are necessary for the system to operate in the second and third modes i e to send SMS messages to the registered users The device is connected to the compu ter via USB or RS232 type connection depending on which type of connection is implemented in the card see fig 1 1 3 Technical Specifications Electrical and Mechanical Specifications Supply voltage 11 24V 50 Hz 300mA max ar 11 24V 300mA max Current used in standby mode 70mA max GSM modem frequency 900 1800 1900 MHz Supported protocols CONTACT ID 4 2 Maximum number of users to whom SMS messages are delivered 5 Dimensions 139x84 mm Operating temperature range 20 4 55 C Generated phone line voltage 48V Generated phone line current 25mA Generated phone line impedance 600 Ohm Ringing voltage of generated phone line 72V 25 Hz Dial tone of generated phone line 350 Hz 12 1 4 Connection Circuit For configurations GSM antenna SIM CARD NyA GSM MODEM Connection for telephone AC DC 1 1 3 5mm O INFO O STATUS Ocsm TELLINE
5. On the Alarm Control Panel you should enable tonal DTMF number dialling mode activate CONTACT ID or 4 2 data transmis sion protocol and enter telephone number of security service panel ATTENTION It is also necessary to enter telephone number of security service on the Alarm Control Panel when you do not need to transmit data to security service and you are using only SMS messaging mode In such a case you can use any telephone number you can use the number consisting of one digit 2 1 Informing Security Service Mode If you want the device to operate in this operating mode you must ensure that all connectors in connec tor group SET MODE PROG are not short circuited jumper is not used When this mode is enabled communicator ETO7 only retransmits data sent from Alarm Control Panel via CONTACT ID or 4 2 protocol to security service panel via GSM audio connection channel The device does not require any additional configurations 2 2 Informing Users via SMS Messages Mode This operation mode is enabled by putting a jumper on MODE connectors in connector group SET MO DE PROG as demonstrated in the example Other connectors must not be short circuited When this operation mode is used the information about the secured object is delivered only to user users and security service is not informed In this case the device decodes the data sent from the Alarm Control Panel via CONTACT ID protocol to user understandable text and sends it
6. via SMS message This decoding is performed according to the preset parameters which can be specified by the user only by using the program ET07 Configuration Tool for more information please refer to user manual of this program SMS messages can be received by up to 5 users 2 3 Informing Security Service and Users via SMS Messages Mode This operation mode is enabled by putting a jumper on SET connectors in connector group SET MODE PROG as demonstrated in the example Other connectors must not be short circuited When this operation mode is used the information about the secured object is received by the user users as well as security service Device retransmits the data sent from the Alarm Control Panel via CON TACT ID protocol to the panel of security service and decodes this data to user understandable text and sends it via SMS message indicator INFO informs only about decoding The text is created by the user This decoding is performed according to the preset parameters which can be specified by the user only by using the program ET07 Configuration Tool for more information please refer to user manual of this program SMS messages can be received by up to 5 users O O O O SET MODE PROG SET MODE PROG SET MODE PROG 3 Appendix 3 1 Restoring Factory Default Parameters To restore factory default parameters disconnect power supply short circuit connect
7. User Manual v1 0 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around be x GSM communicator ETO7 further referenced as system contains a radio transceiver operating in GSM900 and GSM1800 bands Don t use the system where it can interfere with other devices and cause any potential danger Don t use the system with medical devices if this is required in the manual of the medical device Don t use the system in hazardous environment Don t expose the system to high humidity chemical environment or mechanical impacts Don t attempt to personally repair the system System labelling sticker is at the bottom of the device System ETO7 is a device mounted in limited access areas Any system repairs must be done only by qualified safety aware personnel Mains power must be disconnected before any installation or tuning work starts The system installation or maintenance must not be done during stormy conditions The system must be powered by main 11 24V 50Hz 300mA AC or 11 24V 300mA DC power supply which must be appro ved by LST EN 60950 1 standard and be easily accessible Any additional devices linked to the system ETO7 computer alarm control panel etc must be approved by LST EN 60950 1 standard External power supply can be connected to AC mains only inside installation room with automatic 2 pole circuit breaker capable of Phase disconnec
8. dicator STATUS and working mode indicator INFO Device Activity Indication STATUS indicator blinking Meaning Off No power supply or some fault is present Blinking several times per second SIM card is used improperly is not used Indicator is lit The device is working properly and ready for use Working Mode Indication INFO indicator blinking TS off The device is in passive mode Blinking several times per second The device retransmits the data sent from Secu rity Control Panel to the panel of security service this indication is possible then device is working in first mode Indicator is lit The device decodes the data sent via CONTACT ID protocol to textual user understandable information USER MANUAL ELDES ETO7 V1 0 15 2 System Pre operation Communicator ETO7 can operate in 3 modes 1 Informing security service mode transmits information from the Alarm Control Panel via GSM audio connection signal only to security service panel 2 Informing users via SMS messages mode transmits information from the Alarm Control Panel via SMS messages only to registered users 3 Informing security service and user mode transmits information from the Alarm Control Panel via GSM audio connec tion signal to security service panel as well as to registered users via SMS messages This chapter describes pre operation and system operation when each of the above mentioned modes is enabled ATTENTION
9. onality 1 6 System Installation z 1 7 Light Emitting Indicators Functionality s sssssssssssssssssssserssssessessse System Pre operation 2 1 Informing Security Service Mode 2 2 Informing Users via SMS Messages Mode 2 3 Informing Security Service and Users Mode Appendix 3 1 Restoring Factory Default Parameters 3 2 ETO7 Configuration Program re SS lechnical SUPPONE e none rare start using the system A quick start guide is located in first two chapters 1 General Information 1 1 Function Communicator ETO7 is for transferring information from the Alarm Control Panel to the monitoring station via GSM audio con nection channel or and users via SMS message The system van be used in the following applications Property security To make and receive telephone calls via GSM audio connection channel 1 2 Operation Description Communicator ETO7 works over GSM network The communicator transmits CONTACT ID and 4 2 protocol messages and fully imitates telephone line When dialling a number with a telephone or via Alarm Control Panel tonal DTMF number dialling mode must be enabled The user can also call from communicator to the telephone Communicator ET07 can operate in 3 modes i e 1 transmits information from the Alarm Control Panel to the monitoring station via GSM audio connection signal 2 transmits information from the Alarm Control Panel only to the registered users via SMS message 3
10. oo Power e l oo ALARM oo CONTROL PANEL RING TIP AUX 1 5 Connectors and LED Indicators Functionality Main Units Light Emitting Diodes LED GSM MODEM GSM network 900 1800 1900 MHz modem INFO Working mode indicator SIM CARD SIM card STATUS Device activity indicator ANT GSM antenna SMA type connector GSM GSM network quality indicator FUSE 3A fuse Connector Functionality Labelling Explanation AC DC Power supply connection pins AC DC 1 1 3 5mm Alternative power supply connection pins Connected in parallel with AC DC connection Internal diameter of the plug is 1 1 mm external diameter of the plug is 3 5 mm TEL LINE Pins connected to the Alarm Control Panel pins RING and TIP Connected in parallel with RJ11 connection RJ11 RJ11 type connection for telephone Connected in parallel with TEL LINE connection DEFAULT Connectors for restoring factory default settings RS232 COM port connection USB Mini USB port SET Connectors for enabling the 3 operation mode of the device MODE Connectors for connecting the 2 operation mode of the device PROG Not used USER MANUAL ELDES ETO7 V1 0 13 1 6 System Installation NOTE Due to GSM network characteristics it is recommended to use the system ETO7 with the same GSM operator which is used by system users Thus you will ensure the quickest SMS message delivery and receipt NOTE
11. ot guarantee against such events EL DES UAB will not take any responsibility regarding personal property or revenue loss while using the system ELDES UAB responsibility according to local laws does not exceed value of the purchased system ELDES UAB is not affiliated with GSM ope rators providing cellular services therefore is not responsible for network services coverage or its operation Manufacturer Warranty The system carries a 24 month warranty by the manufacturer ELDES UAB Warranty period starts from the day the system has been purchased by the end user The warranty is valid only if the system has been used as inten ded following all guidelines listed in the manual and within specified operating conditions Receipt with purchase date must be kept as a proof The warranty is voided if the system has been exposed to mechanical impacts chemicals high humidity fluids corrosive and hazardous environ ment or other force majeure factors Package Content 1 System ETOT ssssssscsssssscssssscscassasssssssssssosssasestnascessnaacs 2 ETO7 user manual 3 GSM antenna About User Manual Quick Start This document describes remote informing system ETO7 its operation and installation It is very important to read User Manual before CONTENT General Information TM rro 1 1 2 Operation Description 1 3 Technical Specifications 1 4 Connection Circuit 1 5 Connectors and LED Indicators Functi
12. tBe www eldes lt
13. ting circuit in the event of short circuit or over current con Ea dition Open circuit breaker must have a gap between connections of Groundin Bs more than 3mm y AC 230V 50 Hz DC 24V USB cable Fuse F1 type 5x20 mm 3A Slow blown Blown fuse cannot be replaced by the user and the replacement fuses have to be exactly the same as indicated by the manufacturer The device is fully turned off by disconnecting 2 pole switch off device of the external power supply or any other linked device that the system ET07 is powered from P The WEEE Waste Electrical and Electronic Equipment marking on this product see left or its documentation indicates that in the EU the product must not be disposed of together with household waste Copyright ELDES UAB 2009 All rights reserved It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from ELDES UAB ELDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this COMMUNICATOR ET07 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of confor mity may be consulted at www eldes It ce Limited Liability The buyer must agree that the system will redu ce the risk of fire theft burglary or other dangers but does n
Download Pdf Manuals
Related Search
Related Contents
Benutzerhandbuch Une Gestion des ressources humaines à l`interface des Mode d`emploi bref AOC V27M Computer Monitor User Manual Healing at the Cell Level Part 4 Betriebsanleitung Tourno compact / de luxe ACM100 User`s Manual - Chicago Marine Electronics Gf,kgjogùfjopùjophblkgmù jkhgùf johpù jop - Plateforme e Copyright © All rights reserved.