Home

User's Guide

image

Contents

1. can provide you a supply voltage cord Part No M01112 suitable for feeding the charger from a cigarette lighter connector Connection to 90 265 VAC supply voltage ILC4 ILC4 may alternatively be fed from a 90 265 VAC mains with the help of a MICA IL 2 Part No 11274_2 mains adapter available as an accessory from your retailer The red POWER indicator is lit at the charger and it indicates proper connection to the supply voltage Never connect the MICA ILC4 directly to the mains or other AC source The power supply should be continuous and may not be supplied via a timer or any kind of switch CHARGING Insert a MICA IL lamp on the charger The yellow CHARGING indicator stays lit during the entire charging cycle At full charge the green READY indicator turns on Red LED POWER Yellow LED CHARGING Green LED READY Stays on when supply Indicates on going Indicates fully charged voltage is OK charging cycle battery In a fault situation all LED s are turned off Lamp type Battery Charge time IL 600 IL 6000 GT IL60 NiMH with 9 0Ah NiMH battery 11h IL 60 IL 600 with 5 5Ah NiCd battery 7h IL 80 ATEX LED IL 800 5h 30min MICA ILC4 ILC4 VAC is suitable for charging all types of MICA IL lamps The battery voltage will become low during prolonged storage Therefore a new lamp should always be charged prior to use A battery typically gains its full capacity after about five complete charge
2. discharge cycles The lamp can be stored in the charger without a risk of overcharge At the end of a charging cycle MICA ILC4 automatically switches on a When the use of a lamp involves short duty cycles between charging cycles it is recommended that the lamp is left on e g after every 10 cycles of use so that the battery capacity will become entirely empty NOTE the lamp s electronic control circuitry will automatically turn off the lamp before there is any risk of battery deep discharge This procedure prevents the memory effect occurring in NiCd batteries SERVICING ILC4 In a fault situation all indicators are turned off NOTE The red POWER indicator also turns off in a fault situation if any lamp is inserted in the charger that is if the red indicator does not turn on when you remove the lamp from the charger the power feed to the rack is at a fault For repair of a damage caused to the charger please send the unit to an authorized MICA service Your local MICA retailer will help you in servicing and provide the necessary spare parts SPARE PARTS ILC4 1 M11226 ILC4 Update module 2 M00347 ILC Aluminium profile 3 MH0124_2 ILC Bottom Back plate assy NOTE When ordering spare parts always mention type and serial number of your lamp and charger ACCESSORIES ILC4 IL_2 IL 2 AC DC transformer 230 VAC 12 VDC M12200 IL 5 Supply changeover unit M01112 Cigarete lighter cable 12 24 V M01113 12 30 VDC 3m cable Ser
3. ILC4 amp ILC4 VAC Charging Holder User s Guide MICA Read these instructions carefully to extend the life of your ILC4 amp ILC4 VAC Charger by correct handling For more information on other MICA products please contact your retailer ready charging 9 Use of the Mica product must be controlled and accepted by the operator Personnel using the MICA product must be authorised by the operator or a designated representative The operator is responsible for the correct use and maintenance of the product Repair of the MICA product must be carried out by a competent party that is authorised by the manufacturer MICA ILC4 amp ILC4 VAC Charger User s Guide INSTALLATION Mount the MICA ILC4 charger with four screws in a position leaving sufficient space above the charger for insertion of a lamp battery into the charger and removal therefrom The MICA ILC4 charger is specified for use in both indoors and vehicle installations Connection to 12 24 VDC supply voltage ILC4 Use a proper supply voltage cable Part No M01113 for connecting the charger to the vehicle s battery power bus or other 12 24 VDC supply Note correct polarity the red conductor must be attached to the positive polarity When connecting the charger supply voltage cable directly to the vehicle s power bus attach a 10 A fuse box as close as possible to the battery terminal to protect the charger supply voltage line Optionally your MICA retailer
4. ial number MICA ILC4 TECHNICAL SPECIFICATIONS x Input voltage 12 24VDC Different in ILC4 VAC S Charging time 6 11 hours Charge current 800 900mA Z Trickle charge current 100mA 5 Operating temp range 0 40 C 5 Dimensions Hx W xD 153x 138x 88 mm 2 Weight 485gr basic ILC4 WARRANTY MICA lamps and ILC4 Charger are guaranteed for two year from date of purchase against all defects in materials and workmanship in accordance with general warranty conditions Warranty will expire if the electronic circuitry is tampered with or the components thereof are otherwise damaged For warranty servicing please include a copy of purchase action document with the shipment of the defective equipment SPECIAL ILC4 VAC CHARGER Distinctions of MICA ILC4 VAC charging unit in comparison with ordinary ILC4 charging unit Installation and commissioning MICA ILC4 VAC is being installed directly into the VAC network Take care that any timer or similar device should not interrupt the supply voltage Maintenance Only trained electrician should maintain charging unit MICA ILC4 VAC Please contact local retailer for arranging the service Supply voltage 85 264 VAC 50 60Hz Weight 860g The device has electronics inside please use required actions when mag disposing of the device 3 2014 ATEXOR OY We reserve the right to make changes to these user instructions without advance notice eATEXOR

Download Pdf Manuals

image

Related Search

Related Contents

  ASUS NW9152 User's Manual    User Manual - Utilecon Services, LLC  Samsung YP-R0 User Manual  RTS01 - AEM Corp  USER MANUAL - Appliances Online  User Manual - RandersonHall Ltd  Catalogue des transmissions homocinétiques  TouchKit TouchScreen Controller User Manual  

Copyright © All rights reserved.
Failed to retrieve file