        A4910 – Lubri User's Guide
         Contents
1.    User   s Guide am    Whdashe    A4910     Lubr  WH          Applications   7 Monitoring and control of lubrication process  7 Measurement of rolling bearing condition       Ref  No   12112009    ADASH spol  s r o  A4910     Lubri    Contents   IMT OGU GC HOM siss A E vet secgneseusansa 3  What Will You Get with Your Instrument         0      cece ceeseeeeeeeeeceneeeeeeneeseeaseeeeeseeseaneeseenseesoees 4  Instrument and Accessories ies iics dc sieicilccrawctetdiareantaiiasoanresie qroasnnnatastovanrntuaiienanunnd sumer nnmlssuaeusneanaa taauumarasauauarnsesoaias 4  ESTOS You SCN aie en taste eases E O 6  QUICK  Stati scria a a A a a E 7  Two Possible Ways to Measure              ccccccccceececeeeeeceeeeeseeeeeeeeeeeeeeeeseeeeeseeeseeeesseeeeeseueesseeeessneeeseeeeeas 7  istrument Preparation aisia a iia eaa a aa aE Ea a aA aiaa 8  Lubrication and MEASUPEMENL              cccccccecccececeeeceeceeeceeeceeeeeeeeeesaeeseeeseeeseeeseeetaeeseeeseeeaeeeseeeaeeesaeees 8  Determining of Lubrication Interval and Amount of Lubricant                     ssccsssesseeseeeees 10  Goal of Maintenance in Lubrication ProCeSs              ccccccceecccesceeaececaeececeeceeeecesseeeeseeeesseeessesessaes 10  Procedure for Lubrication OptiMIiSation               cccccccccceecccceceeseeeeceeeceseeeeeeeeeeseeeeeseecesseeeesseeeeseeeeeeas 10  How Much Lubricant Needs to Be Added                 cccccccccescccesecceeecececeucecaueeceeeceeesaeeseueessueeseaeenaaes 11  instrument DESC HID TION sssrin 
2.    ii Blinking signals a low    signal level from  bearing    Picture on the left shows greasers signalling proper instrument start  Middle picture shows  measurement before lubrication and right shows measurement after lubrication    Warning    If the display stays off after switching on the instrument  the batteries are weak     change  them     9    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    Determining of Lubrication Interval and  Amount of Lubricant    Goal of Maintenance in Lubrication Process    The goal of maintenance is a long lifetime of rolling bearings  We need to optimise lubrication to  achieve this  To achieve the best possible state of lubricated bearings and save lubricant at the same  time  we need to determine regular intervals  when we are going to perform lubrication  Another  question is the amount of lubricant for each of the lubrication points    Starting points are intervals and amounts determined by a manufacturer  We had performed a large  amount of testing on bearings directly in manufacturing  We have found that the intervals  which are  determined by manufacturers  are always too long  and that at the end of these intervals the bearings  are not working under optimum condition     Procedure for Lubrication Optimisation    The A4910 Lubri instrument enables you to measure an act
3.  232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri     for attachment at cooling ribs   Both pads have an M6 threads for screwing on the sensor        Pad Installation    You will need the following  angle grinder  files  sand paper  degreaser  spirits  thinner   measurement  pads  and glue    The surface where you need to attach the pad needs to be prepared as follows      remove paint  corrosion and eventual unevenness by grinding     degrease    Both types of pads are being attached to a measuring location by METAL TECH SG glue   See www thortex com   product  You can use other glues with similar properties     It is dual component epoxy glue with characteristics suitable for this purpose   The two components react chemically when handled and after proper mixing and drying create a hard  material  which is resistant to pressure  temperature and humid environment     In case of the simple pad proceed as follows  With a sharp knife cut about 3 mm thick slice and by wet  fingers work into homogeneous matter  From this make about 2     3 mm thick cylinder and put it on a  rough side of the pad        Then press the pad onto the previously prepared  cleaned spot and turn back and forth under steady  pressure to glue it onto the machine  Make sure the glue is being pushed out evenly around the  circumference of the pad  The purpose is to create as thin a layer o
4.  cz    ADASH spol  s r o  A4910     Lubri    Before You Start    ignoring any recommendations mentioned below may cause failure of the instrument     Operating with power higher then 24 V can cause an accident        1  Never connect any other type of sensor than ICP into the socket marked ICP   If unsure  contact your supplier     2  Never plug the A4910 into 110   230 V voltage     3  To power the A4910  use batteries  rechargeable batteries  with max  nominal voltage of 1 5  y     4  To power the A4910 use only alkaline or rechargeable  NiCd  NiMH  batteries   Regular carbon zinc batteries are not suitable     WARNING   Use correct battery polarity     Incorrect polarity will cause destruction of the  instrument        6    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    Quick Start    The aim of this chapter is to introduce you to A4910 Lubri  and  without reading a complete User   s  Guide  try this instrument in practice     Two Possible Ways to Measure    A sensor  a standard accelerometer with sensitivity of 100mV g and ICP power   which needs to be  mounted on a bearing housing  is used to measure lubrication     We have two possibilities how to do this     1 The sensor is mounted on a lubrication head    This option enables a quick service since the lubrication head is transferred together with the sen
5.  not much going  on in the beginning  which means that the lubricant is pushed toward the bearing  however it is not  there yet  At the moment when the lubricant reaches the bearing  the column decreases  usually its  upper red part disappears and only the green lower part remains  and noise in the headphones  decreases also  We need to add a little more lubricant  and if there is no further decrease  we end the  lubrication process     If  at the beginning of measurement  the greaser in the lower right hand corner starts to blink  then the  signal from a bearing is very low  We have either new or a very well greased bearing  In this case we  suggest using headphones to finish lubrication     Before we start lubricating another bearing we piece to reset after the previous measurement  It is    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    necessary  since  during bearing operation  values showing bearing status are different for every  bearing  The values are different even for bearings of the same type used on different machines or  under different loads  Reset is done by a short push of the Mode button  A lubrication value in the  upper right display corner will start blinking during reset     Complete switch off is done by a long push of the Mode button     New measurement    is signalled by  A blinking    
6. 32 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri       f  1 Push gently    Battery compartment opening       ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    Correct polarity    Connecting of Headphones    The instrument is equipped by a 0 5 W amplifier for listening to a bearing noise  We can connect the  headphones by a stereo 3 5 mm jack marked PHONES on the top of the instrument  see picture in the    sensor connecting chapter   Suitable volume can be set by arrows A or Y     When the instrument is switched on or off  range is changed  or the sensor is connected or  disconnected  a short  unpleasant crack can be heard due to a transitional effect  This is not a defect     Be careful not to overload the headphone amplifier by excessive volume  This will distort a  signal in the headphones     You can use any headphones with nominal impedance higher than 8 Q     15    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    Measurement pad instalation    Selection of Measurement Point    Two conditions are important for exact measurement o
7. 910     Lubri    Instrument Operation    Mode button    Mode button is used to switch the instrument on off and for measurement reset  The button needs to  be pushed for a longer time to switch off     Buttons A and Y    These buttons are use to control volume in headphones  Arrow A increases volume  arrow Y  decreases it     Error Indications    Errors are indicated on an instrument display   If there is a problem with cable or sensor  the display will show    ICP ERR     see picture   If we get an  ICP ERR  we need to check      connecting cable  broken or short circuit      sensor    If there is another internal fault  the display will show    CPU ERR     see picture   If the error constantly  repeats itself  contact your supplier or manufacturer        Sensor and instrument power supply errors    Changing Batteries    To power the instrument  use AA size alkaline batteries or NiMH rechargeable batteries with  nominal voltage of max  1 5 V  Use of regular carbon zinc batteries is not recommended    The batteries are accessible after you open a small lid on a bottom of the instrument  You can open  the lid by pushing on its bottom side  hinge side   the upper side then opens easily     see the picture   DO NOT APPLY FORCE    Correct polarity is shown in the picture     Do not forget to switch the instrument off before you open the battery compartment lid   Never handle the batteries when the instrument is switched on        13    ADASH Ltd   Czech republic  tel    420 596 2
8. a a ENE 12  Horument Operationen E e ceeueaeaers 13  E Or NOCAUT emote en eee rr er a Eee ee Oe ee eee 13  Chanongo i oye ia  2  i  Rese semester rca ete rte er ane E R R 13  Connecting of FASC ACDINOINCS ssc  ircs cosets css gacs ates oe aca eenntehcae a ceb ine eaeice sna cance ince eae aesdieeee 15  Measurement pad instalation              cccccssseecesseeceesseeeenseeeenseeeeenseeeeeseeeonseeeesseesonseesoeseessoees 16  Selection   f MEASUFEMENT POUT wees ceslitsccieiiedccteierns a a o catia ei 16  Preparation of Measurement Point                ccccccecccceececeeeeeceeeeceeeeeseasesseecesecessaeeessaeeessaeeeseneesseaeenes 16  Typesof Measurement PACS iti cussstses cosiuenst aa e a o aE eerie 16  Pad MSU AU oN nan a A a eaten aeeonaiates 17  Bearing Condition Measurement for Diagnostic PUrPOSGG              ccceeseeeeeeseeeeneeeeeeneeseees 19  Technical Specifications Adash 4910     Lubri                c ceeceeseeeeseeseeeseeseeeseenseeeseenseeseeennees 20    2    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    introduction    There is an increasing demand for an instrument which is able to simply check lubrication of rolling  bearings and also the condition of these bearings     Every machine does have in its specifications how much lubricant every one of its bearings uses in a  specific amount of operati
9. al AC signal 8 Q   0 5 W for external headphones  listening to measured    signal   Power    2x1 5V  AA alkaline batteries  or 2x1 2V  NIMH AA rechargeable batteries   Consumption    max  400 mA using headphones  Dimensions    150 x 60 x 35 mm    Weight    approx  250 g       20    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    
10. ant Needs to Be Added    The result of lubrication interval optimisation procedure is also the lowest value of a bearing condition   Our goal is to reach this value by regular lubrication  We add lubricant long enough to reach this  reference value    We need to realise  however  that a bearing is being worn out  and so its working condition worsens   That is why it is not possible to constantly reach  during its lifetime  its original reference value during  lubrication     The lubrication rule is then as follows     Lubricate while the bearing condition value decreases  then stop     11    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    Instrument Description    Input connector for  lubrication sensor  connector  BINDER  712    Output headphone  connector   Stereo jack 3 5mm    measured value    Bar indicating  lubrication state    Volume up    Volume down    ON OFF Switch       ADASH 4910  Lubri  Batteries   rechargeable  batteries     Adash 4910     Lubri     Note  The A4910 Lubri instrument has the LB TRUE RMS measurement method preset  this method  is capable of numerical evaluation of a bearing state     12    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4
11. bricant is ideal  This way  it is ensured that we do not under or over lubricate     When we use this instrument we can shorten recommended lubrication intervals  since the instrument  always exactly determines the ideal amount of lubricant needed     As a result of using the A4910 Lubri instrument  your machines will be maintained in their best    lubrication condition  The instrument enables you to make the whole lubricating process simpler and it  normally reduces the consumption of very expensive lubricants     3    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    What Will You Get with Your Instrument     Instrument and Accessories    The instrument case contains      instrument A4910   Lubri     lubrication and bearing condition sensor    magnetic base for sensor     coiled cable to connect sensor     headphones     1 5V alkaline battery    ADASH 4910  Lubri       The complete lubrication set  4    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri       Application example    5    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash
12. ered into a  computer  If you want to successfully diagnose rolling bearing conditions use the following  suggestions     1  Make a list of machines and bearings you want to measure  Mark each measuring place    2  Measure every bearing at the same place under the same operational conditions    3  Mark the values only after proper bearing lubrication    4  Determine a reference value for each bearing  Measure the reference value at a time when the  bearing is in a good operational condition  the best is after a successful installation of a new bearing    5  Record all measurements into a notebook or computer    6  We are capable to determine conditions of rolling bearings based on increasing values      if there is an increase of 100  against a reference value  we need to understand it as a warning and  the bearing should be investigated in detail at the earliest opportunity      if there is an increase of more than 400   a critical change in operational conditions of the bearing  took place  This bearing should be replaced as soon as possible     19    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    Technical Specifications Adash 4910     Lubri     lt 7 Technical Specifications     Input    1x ICP powered accelerometer with 100 mV g sensitivity for measurement and recording of  lubrication  Output    1X monoaur
13. f glue as possible at the  attachment location      WARNING  DO NOT PUSH OUT ALL THE GLUE      Extra glue can be removed or smoothed around the pad  Cover the pad by its cover    When using T pad the amount of glue depends on the distance between cooling ribs  so it is not  possible to exactly determine this amount  Just as with the simple pad you have to clean and  degrease the space between ribs where the T pad is going to be attached  This space needs to be  filled by sufficient amount of glue so after inserting of the T pad only the cylindrical part of the pad  would stay exposed  Pack the glue around the pad then cover the pad with a cover     17    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri       Placement of measurement pads on a machine    18    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    Bearing Condition Measurement for Diagnostic  Purposes    This instrument also takes measurements of rolling bearing conditions in addition to lubrication  measurements  For this purpose an actual value of bearing condition is displayed at the upper right  side of the display  It is possible to follow a time trend  if these values are recorded or ent
14. f lubrication state    Firstly  to pick a suitable attachment place for the lubrication sensor  i e  place as close as possible to  the bearing  The bearing housing is ideal for this  If this is not possible  we should choose a part of a  machine  which is in as firm as possible contact with the bearing  Covers etc  are not suitable as  measurement points     the points have to be as rigid as possible    The other condition is preparation of the measurement place     gluing on a measurement base     Note  If your company performs vibration diagnostics on its machines  you can utilize measurement  points that have been created for this purpose for bearing lubrication measurements also     Preparation of Measurement Point    In order to obtain a quality measurement  we need to properly prepare these places  It is necessary  in  regularly performed lubrications  to always attach a sensor the same way at the same place  In order  to perform bearing lubrication measurements  we need to attach a sensor through magnetic base or   even better  screw it on  For practical reasons most users use the magnetic base  since screwing  takes more time  The magnetic base is a very strong magnet firmly screwed on to the sensor  which is  then magnetically attached to a surface of a machine  The quality of the attachment significantly  influences the measurement results  If the sensor rocks or jumps etc  the measurement is useless   Also a thick layer of paint or corrosion lowers the usefulness 
15. ion sensor with ICP power  The sensor must  be a standard accelerometer with 100 mV g sensitivity  The instrument is equipped with its own  source of ICP power for connected sensor    The sensor needs to be connected at the right side plug using the supplied cable  Then a magnetic  base needs to be screwed on to the sensor     connector to plug in  headphones   stereo jack 3 5mm     connector to plug  in the sensor       Top view of the connectors    Lubrication and Measurement    If the instrument is ready  we need to attach a lubrication head  If a sensor is not a part of lubrication  head  we attach it  by using a magnetic base  to a formerly prepared and glued measuring base  Do  not forget to remove the cover of magnetic base  which protects the magnet from weakening in  storage    Switch on the instrument by pressing Mode  Provided that the batteries are OK  the instrument display  will show running bands and greasers  red and green   Then the instrument will automatically measure  an actual lubrication state  If your headphones are connected  you will be able to clearly hear the    bearing noise  Using A and Y arrows you can increase decrease its volume  On the left side of the  display is a column  whose height indicates a bearing lubrication state  After the instrument is switched  on  it always reaches a maximum level  We need to slowly start adding lubricant  while monitoring the  height of the column on the display and the noise in the headphones  Usually there is
16. of a measurement  The surface of the  magnetic base is carefully ground and the same type of surface is needed on the machine  This is  of  course  practically impossible  since we are only capable to create an evenly ground surface of 3x3 cm  in a workshop  Even if we were able to create such a surface  it would not last since a quality of  bearing housing steel  for example  is not high  and it quickly succumbs to corrosion  This renders the  place unusable     The solution is to use measuring pads  They are small cylinders with diameter of approx  26 mm and  10 mm tall with ground surface  They are made from magnetic stainless steel  They are glued to  appropriate places on a machine with a special glue  which ensures perfect transfer of high frequency  vibration  The pad is covered by a plastic cover  which is only removed at the time of measurement   Another advantage of the cover is that in case of a machine being painted your measurement point is  preserved  Painting over the measuring pad destroys it     All you need to do before gluing one of the pads is to degrease and roughly grind a machine surface in  an appropriate spot  The pads last indefinitely  or until they are forcibly removed     Types of Measurement Pads    We supply two basic types of the measurement pads for measuring location preparation  They are  a  simple measuring pad for easily accessible places on a machine and special T pad for electric motors    16    ADASH Ltd   Czech republic  tel    420 596
17. onal hours  A task of each technician or engineer is to regularly check all the  lubricated points and maintain lubricant at sufficient levels  Either state  lack or excess of lubricant  are  harmful for a rolling element bearing  The result is always excessive stress on the bearing and  consequently excessive wear  Every lubricating point has a lubrication time interval  in hours of  service  and also an amount of lubricant that needs to be replenished  This manner of lubrication  control has a significant disadvantage     The amount of lubricant that any bearing actually needs for proper operation changes during its  lifetime  Longer lubricating intervals in the case of a new machine are usually not sufficient for a  machine after several years of operation     It is clear that it would be useful to be able to determine a state of a bearing somehow and replenish  only as much lubricant as is actually needed  Controlled lubrication increases bearing service life and  lowers costs for lubrication and repairs     We have collected a large amount of knowledge by researching machine long term operation and  lubrication here at ADASH and we have applied it in developing the instrument A4910   Lubri  It is  simple to operate  and user s training takes less than one hour  The main use of this instrument is in  the lubrication replenishment process  During this process the instrument measures the actual  lubrication condition of a bearing and tells the operator when the amount of lu
18. sor   The disadvantage is a partial loss of sensitivity  since the lubrication head attenuates the measured  signal    2 The sensor is mounted next to lubrication point on a bearing housing  measurement pad  recommended     This option enables a perfect measurement  The disadvantage is a longer preparation  since the  lubrication head and sensor must be mounted separately        1  Sensor is on the lubrication head 2  Sensor is mounted next to lubrication point    If vibration diagnostic measurements are performed on a machine  then a measurement pad is already  mounted  This pad can be used also for lubrication measurements     A procedure for mounting of a measuring base is shown at the end of this Guide     T    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    Instrument Preparation    The preparation of this instrument for measurement is easy  All you need to do is to put in batteries  and plug in the lubrication sensor and screw it on a magnetic base     Remark  The battery  rechargeable battery  space is behind a door in the base of the instrument   Open the door by pressing its lower edge  the edge with hinge  then you can easily replace the  batteries     see chapter  Instrument Description     Battery Change     Plugging in the Lubrication Sensor    Lubrication measurements require plugging in a lubricat
19. ual working condition of a bearing  a  numerical value up on the display   We can utilise this measurement for optimisation of lubrication   using the following steps     1 We need to lubricate a machine thoroughly    2  Then we measure and record a  reference  value of the bearing condition    3  We need to repeat this measurement regularly in 1 10th lubrication intervals recommended by a  manufacturer    4  If the condition value of the bearing increases to double of its reference value  then further  lubrication is needed  and time from reference measurement to this new lubrication is our new  optimum lubrication interval     Remark  In case that we overlubricate a bearing at the initial reference lubrication  the bearing  condition value can initially decrease  until the amount of lubricant in the bearing reaches an optimum   minimum  value  Than we use this time and value as our initial reference     Example   The manufacturer recommended lubrication interval is 600 service hours  The reference value is  0 25g  The control measurements are performed every 60 service hours  see Table      p60  026       The measured value reached double of the reference value in 240 service hours  Optimum lubrication  interval is then 240 service hours     10    ADASH Ltd   Czech republic  tel    420 596 232 670  fax   420 596 232 671  email  info adash cz  For more technical and contact information visit www adash net  www adash cz    ADASH spol  s r o  A4910     Lubri    How Much Lubric
    