Operating Instructions Fire Alarm System EBL512

image

Contents

1. 101 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x press ESC NOTE_1 During the test the following information will be shown in all other c i e displays Zones in test mode 001 002 003 004 NOTE_2 If an alarm point e g a manual call point is in alarm state when the test mode is ended there will not be a fire alarm activated Instead the alarm point will be disabled and has to be re enabled again via menu H2 B5 NOTE_3 When the Fire door closing function is used the fire door will be closed when the detectors controlling the door are tested in test mode 102 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 25 Disable or re enable H2 A whole zone one or more alarm points within a zone and or control outputs can be disabled via menus H2 B1 B3 This possibility can be used when a temporary disablement is wanted e g craftsmen working in the premises etc The function Enhanced disablement is enabled as default i e disabled alarm points cannot activate Pre warning fire alarm or fault If this function is not enabled via Win512 version 2 7 x fault can be activated but not pre warning or fire alarm This is a violation to the ENS54 2 standard Addressable manual call points can be disabled but shall normally not be disabled However
2. 16 1 16 2 16 2 1 16 2 2 Pre warning reset Pre warnings are non latching i e they will be automatically reset when the alarm point zone is no longer above the pre warning level Outputs activated by pre warning will be de activated In some cases after a programmable delay time Fire alarm reset NOTE The detectors having activated fire alarm shall after reset be inspected tested and replaced when required One of the following alarm reset alternatives is valid This is selected via Win512 version 2 7 x All is default All All activated fire alarms alarm points zones will be reset by pressing Reset P3 once This is in accordance with the EN54 2 standard NOTE The push button has to be pressed for min 0 5 sec When all fire alarms are reset LEDs Fire L1 and Alarms queued L6 are turned off If there are other conditions e g a fault condition the corresponding information will be shown e g a fault message for the priority order see chapter The information area priority order page 23 All outputs for fire alarm are reset i e de activated If a key cabinet is installed the key to the building has to be put back into the key cabinet within 5 minutes If not a fault will be generated and a fault message will be shown in the display see chapter Key cabinet alarm reset page 52 Single Each fire alarm alarm point zone has to be reset one by one NOTE This fun
3. When a fire alarm is activated e g an addressable alarm point the presentation number Zone Address will be shown in the control unit display see page 40 as well as in the ext FBP 1826 1828 display There will also be shown a user definable alarm text if programmed All user definable text messages up to 40 alphanumeric characters each are created and downloaded included in the site specific data SSD via Win512 version 2 7 x See Planning Instructions chapter User definable text messages Each alarm point can have a unique text message Each zone can have a unique text message Each zone line input can have a unique text message The user definable text messages will be printed out when a printer is available 4 This is also valid for the Ext Presentation unit 1728 and the Alert Annunciation units 1735 1736 88 Panasonic Eco Solutions Nordic AB MEW01473 20 Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x New system program S W version download 20 1 The latest software S W version of the EBL512 G3 system program is factory downloaded before the delivery Due to continual development and improvement different S W versions can be found An EBLS512 G3 control unit in a mixed system has to have the software EBL512 G3 United version 2 7 x The valid S W version for the Main board 5010 and the MMI board 5011 respectively can be read in menu H4 U7 syste
4. Number of disablements by time channel 2 not open menu ESC U2 Disablement by time channel Scroll to another menu or press ESC 120 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 27 3 Open doors H4 U3 If any door in the system is open the following symbol is shown in the al display s symbol area a See also chapter Open door page 36 This menu is a dynamic list of all open doors in the system Menu According to chapter Access see page 98 Scroll to menu H4 H4 Present system status Mal U1 Disablement U2 Disablement by time channel U3 Open doors U4 Sensor values U5 Sensors activating SERVICE signal U6 Event log U7 Information Scroll to menu U3 U3 Open doors a When lt is pressed the disablements will be shown in the A dynamic list in which display Some examples you can scroll with W or Door open control unit 00 A yyyy mm dd hh mm If printer is mounted the Door open FBP x CU xx soft key Print will be yyyy mm dd hh mm visible else not Press ee Print for a print out of all ee items in the list If there are no open doors Open door 1 to 2 of 2 when lt is pressed the list view will not open ESC U3 Open doors Scroll to another menu or press ESC NOTE During printing Print will be replaced with Abort printing 121 Panasonic Eco Solutions Nordic AB MEW01473 Rev Ope
5. Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 33 Change access code for daily duties H10 For security reasons the default code should be changed Access According to chapter Access see page 98 Scroll to menu H10 H10 Change access code for daily duties rn Access code l New code Verify KKK Enter the old code the Access code The digits are replaced by new code and the new New code Verify ah in the display code again Incorrect access code NO change MEORE EKE ACInOT correct Try again H10 Change access code for daily duties The access code was correct and is now changed to the new code Scroll to another menu or press ESC X NOTE After change of access code it is recommended do Safe shutdown of the control unit see menu H8 S8 This will save the SSW data e g the new code in a Flash ROM see page 154 If the valid access code is unknown a back door code is available 167 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 34 Annual control The building occupier is highly recommended once a year to do some tests beside the monthly tests To avoid the Fault tx output s to be activated they can be disabled via menu H2 B9 or via an open door se chapter Open door page 36 Regarding the fault condition see chapters Fault page 54 and Fault messages
6. The p c b has to be replaced FAULT Checksum MMI program comaa o Vince sox A fault in the control unit xx MMI board 5011 software System fault is turned on This is a very serious fault Call for service personnel engineer immediately 512 A fault in the control unit xx S W The main board 1556 might have to be replaced This is a very serious fault Call for service personnel engineer immediately 512 G3 A fault in the control unit xx Main board 5010 software LED System fault is turned on This is a very serious fault Call for service personnel engineer immediately network x network 0 Check the TLON network cables connections Faulty TLON connection board 1590 5090 The control unit has no power Can be shown in conjunction with new S W download 60 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Can be shown in conjunction with new software download and or when commissioning a system This fault can be generated due to a bad TLON network i e communication problems One or more control units might have data stored that is not the same in all control units If a control unit restarts in conjunction with this fault a synchronization will start automatically otherwise a synchronization has to be started via menu H8 NOTE It is important that all control units that are supposed to exist SSD downloaded via Win512 are ru
7. 129 S2 Re connect loop zone line input S3 Acknowledge SERVICE signal S4 Clear weekly average S5 Test of alarm devices S6 Safe shut down of control unit S7 Activate address in alarm mode S8 Synchronize the control units S9 Change code for service maintenance 10 Change code for PC communication Scroll to menu S9 Sy S9 Change code for service maintenance code for service maintenance i sl Access code l New code Enter the old code the Access code The digits are replaced by new code and the new New code Verify ear 4 in the display code again Incorrect access code NO change The access code was not correct Try again Sy S9 Change code for service maintenance code for service maintenance The access code was correct and is now changed to the new code Scroll to another menu or press ESC NOTE After change of access code it is recommended do Safe shutdown of the control unit see menu H8 S6 This will save the SSW data e g the new code in a Flash ROM see page 154 If the valid access code is unknown a back door code is available 160 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 31 11 Change code for PC communication H8 S10 As a protection against unauthorised personnel programming the system via Win512 version 2 7 x an access code level 3B amp 4 for PC connection is required For secu
8. 2 7 x r Download software to control unit Software file Download option E No MMI board Communication setting COM pot amamen T R 2 Set the Main board 5010 in boot mode i e hold the Main board Boot button SW2 down and push the Main board RESET button SW1 momentarily Release the BOOT button The Main board LED D24 will be turned off while the Main board is in boot mode 3 Start the download i e click Start LED Operation L5 will be turned off LED Fault Disablements General fault L9 is turned on indicating that EBL512 G3 is in the boot mode LED System fault L7 will be turned on If it is an EBL512 G3 type 5000 i e with front another dialog box opens r Set MMI board in boot mode and press OK Set the MMI board 5011 in boot mode i e hold the MMI board BOOT button SW2 down and push the MMI board RESET button SW1 momentarily The buzzer stats sounding Release the BOOT button The MMI board LED D18 will be turned off while the MMI board is in boot mode 4 Click OK The buzzer will be silenced and the download starts The download status is indicated by the progress bar 5 When the progress bar has gone from red to green the download is completed and the following dialog box opens 90 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version
9. Blinking One or more supervised outputs type Alarm device have generated fault s This is also valid when the c i e has no contact with a unit with such an output e g 3377 3379 3364 etc P Fire brigade tx yellow Steady cont Output s for Routing equipment disabled via menu H2 B3 or B9 or via open door Blinking Routing equipment power supply output or one or more supervised outputs of type Routing equipment have generated fault s This is also valid when the c i e has no contact with a unit with such an output e g 3361 etc Routing equipment 13 Fault tx activated yellow One or more not acknowledged faults Output Fault condition for fault tx routing equipment is activated L12 fis Sensitive fault detection mode see menu H5 A2 is on Fire brigade tx delay The Alert Annunciation function is enabled i e time yellow channel controlling this function is on The AA function is described in the EBL512 G3 Planning Instructions chapter Alert Annunciation LED L14 will be on if the AA function is enabled for at least one alarm point zone Normally is only one time channel used for this function but two or more channels can be used The AA function can as an alternative be continuously on gt Main board 5010 term block J3 3 4 fuse F8 TS00mA L 250 V TRS See also chapter Fault acknowledge page 81 20 Panasonic Eco Solutions Nordic AB MEW0147
10. COM loop Scroll to another menu or press ESC 135 Panasonic Eco Solutions Nordic AB MEW01473 28 7 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Display statistics for communication H5 A6 The statistics can be used during commissioning service etc Number of pollings is the number of pollings questions sent out by the control unit to all the units connected on the COM loop Parity fault is the received number of parity faults and faults in relation to pollings Number of bit faults is the received number of bit faults and faults in relation to pollings No answer is the received number of answer faults no answers and faults in relation to pollings Bit length fault is the received number of bit length faults and bit length faults in relation to the pollings The number of Parity faults Number of bit faults No answer and Bit length faults shall normally be 0 or as close to 0 as possible If not there are some communication problems that have to be investigated Check the COM loop connections and the loop units All values are set to 0 after restart and or after re connection of COM loop via menu H8 S2 Text in display Comments According to chapter Access code for service and maintenance H5 and H8 see page 129 A1 Calibration of supervised outputs Sensitive fault detection mode Service mode for COM loop Display current cons
11. Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 1 Introduction EBL512 G3 Operating Instructions is a document intended to be used by the end user and the fire brigade personnel as well as service commissioning engineers Due to continual development and improvement different S W versions are to be found This document is valid for S W version United version 2 7 x On the date rev date of this document x 0 Since the EBL512 G3 control unit c i e is produced for many countries the look the texts the functions etc might vary Products Consists of one or more parts HW according to a Product Parts List A product has e atype number 5000 EBL512 G3 c i e Configured for 128 256 or 512 alarm points and with or without printer depending on article number 5001 EBL512 G3 c i e No front panel and no Plexiglas in the door Configured for 128 256 or 512 alarm points depending on the article number e an article number is often the same as the type no but a country code can be added e g SE for Sweden If also the letters PRT are added in the article number the product comes with a printer If digits are added to the article number they are showing the number of alarm points configured e g SOOOPRTSE 128 e a product name e g EBL512 G3 CU 128 alarm points with printer HW A HW e g a printed circuit board has e atype number e g 5010 e an article
12. OQoQQqoaoa es Ay Wy gt D Hy gt 74 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x PAUD SN Crer OOPER xx ASF5 lt gt CU AVTE SIVSCIIES LCoS x xx ASF4 lt gt CU is Sn eien Lec x xx ASF3 lt gt CU WINS Sin eee looa 2 xx ASB CU BAUE oM eire Ikeee x xx ASPI CU AUTT Sh cire eop x xXx A O0 CU Short circuit on the COM loop x one or more short circuit isolators are connected on the loop Check the specified and isolated segment on the loop e g CU lt gt ASFO between the control unit and short circuit isolator no 0 Each 10 minute is an attempt made to re enable the isolated segment again PAULTS Shore Circuit loop x Control vnit xx SCInn lt gt SCIinn SCI nn lt gt SCI nn describes between which Short Circuit Isolators 4313 the short circuit is located nn A B 00 01 02 03 04 05 06 amp 07 A amp B is the built in isolator in the EBL512 G3 c 1 e A direction and B direction respectively If no SCI is used the information will always be SCI A lt gt SCI B If one SCI no 0 is used the information will be SCI A lt gt SCIOO or SCIOO lt gt SCI B and so on There will also be a FAULT No reply message for each unit not found by the c i e If there are several short circuits on the loop the mess
13. On select On and press lt to turn on the sensitive fault detection mode On A2 Sensitive fault detection mode Scroll to another menu or a press ESC 131 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 28 4 Service mode for COM loop H5 A3 Action Menu ii Scroll to menu A3 NOTE The following is valid for an EBL512 G3 control unit If the control unit number CU XX is valid for an EBL512 control unit the function is different See system EBL512 Operating Instructions This mode can be used when commissioning an installation and by maintenance The COM loop communication polling will be turned off but there is still voltage 24 V DC on the loop in the A direction only in the B direction only or in both directions at the same time A volt meter can be used e g to check the voltage voltage drop on different places on the loop or to find a single break on the loop It is recommended to do this check also when EBL512 G3 is power supplied via the backup battery only since the battery voltage can be different compared with the rectifier voltage due to the battery condition backup duration etc The Service mode for COM loop is indicated by LED Fault Disablements General disablements L10 If you log off this menu the Service mode for COM loop will be terminated automatically NOTE If short cir
14. Output unit Addressable unit with programmable control outputs Connected to a COM loop see below Output Control output Defined or programmable function Relay output or voltage output supervised monitored in the c i e or an output unit Short circuit isolator ISO Addressable unit for automatic disconnection of a part segment of a COM loop see below in case of a short circuit on the loop According to EN54 2 One ISO is required per 32 alarm points on the COM loop Display unit DU Addressable unit for fire alarm presentation incl user definable text messages if programmed COM loop Loop a cable with two wires to which all the addressable units can be connected Starts in the c i e and it returns back to the c i e Control Unit C U C LE Control Unit Control and Indicating Equipment Unit to which the alarm points are connected via a COM loop Indicates fire alarm fault condition etc Fire Brigade Panel amp Control Panel see below included or not included Printer included or not included Fire Brigade Panel FBP Unit intended for fire alarm presentation etc for the fire brigade personnel Can be a part of the control unit front or a separate unit external FBP In the ext FBP a printer can be included or not included Control panel CP A part of the control unit front intended for the building occupier service personnel etc to communicate with the contro
15. Re enable output Disable re enable output type Disable re enable alarm devices Disable re enable routing equipment B10 De activate alert annunciation function B5 Re enable zone address Re enable zone address lo 02 If there are no zone zone address 002 01 addresses to re enable zone address 006 03 menu B5 will be shown zone address 073 01 again The disabled zone addresses will be shown in a list Use VW or A to select the zone address or write the zone address and press lt Re enable zone address 02 01 Re enable another zone zone address 006 03 address or press ESC zone address 073 01 Scroll to another menu or press ESC 109 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 25 6 Re enable output H2 B6 Disabled outputs are listed in menu H4 U1 from which it is possible to get a print out When all outputs have been re enabled The LED Fault Disablements General disablements L10 will be turned OFF if there are no other disablements in the system Menu According to chapter Access see page 98 Scroll to menu H2 H2 Disable or re enable Disable zone Disable zone address Disable output B4 Re enable zone Re enable zone address Re enable output B7 Disable re enable output type Disable re enable alarm devices Disable re enable routing equipment B1
16. The following types are available Product type no 4580 8 zones expansion board 4581 8 relay outputs expansion board Regarding the expansion boards see also the EBL512 G3 Planning Instructions and drawings The control units can be EBL512 units 1548 1549 or 1550 with S W version 2 7 x and EBL512 G3 units 5000 5001 with S W United version 2 7 x Printer 5058 is a spare part for the c i e type 5000 with a printer i e it comes without a mounting frame etc 13 Panasonic Eco Solutions Nordic AB MEW01473 3 1 3 3 2 3 3 3 4 3 5 3 5 1 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Power supply The main power source is a built in switched power supply rectifier 5037 230 V AC 24 V DC 6 5 A The second power source is a backup battery 2 x 12 V In the c i e is space for two 27 Ah batteries Larger batteries up to 65 Ah have to be placed outside the c i e The batteries and the power supply are connected to the Main board 5010 which handles the charging of the batteries etc See the EBL512 G3 Planning Instructions chapter Power supply for more information S W versions Due to continual development and improvement different S W versions can be found When installing a new control unit in a system with older control units you might have to update the S W in the old control units The same S W version is required in all control un
17. a programmable input in control unit no xx The fault is to be found in the external power supply equipment which has a fault output connected to a programmable input in control 64 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x unit Xx FAULT External presentation unit xx Control unit sox 1728 Ext Presentation Unit EPU The EPU xx connected to control unit no xx is programmed as another type in the SSD or a fault in the unit PAULIN External presenta c on UNIE XX expansion Poara EON e eO Uinie xx EPU 1728 The unit is programmed as another type of unit than the SSD says or fault in the unit 512 Fault in the SSI EBL512 settings downloaded via Win512 512 G3 The configuration settings have been changed in control unit no xx e g because of some external disturbance The main board has to be replaced The LED Fault is lit on a fan control module connected to control unit xx Fan no xx has been activated but the corresponding I O unit 3361 input has not been activated within the programmed time Check the fan and the cables connections NOTE In the Australian and New Zealand conventions this fault is not latched irrespective of if all other faults are latched Only valid in the New Zealand convention New Zealand FB Silence switch outside switch is turned on in control unit no xx i e from not act
18. alarm see above Key cabinet alarm is reset like a normal fire alarm see chapter Fire alarm reset page 50 This alarm will also generate a fault message see chapter Key cabinet alarm reset page 52 It is indicated by LED Fault L9 NOTE The Fault tx output s will not be activated by this fault Key cabinet opened in conjunction with a fire alarm If a normal fire alarm already is activated in the c i e the fire brigade personnel can open the key cabinet without activating any key cabinet alarm or fault Restoring the key after a fire alarm When all fire alarms in the system are reset see chapter Alarm reset page 50 the key has to be restored into the key cabinet within 5 minutes If not a fault will be generated see chapter Key cabinet alarm reset page 52 46 Panasonic Eco Solutions Nordic AB MEW01473 15 6 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Co incidence alarm 2 address zone dependence The co incidence alarm function is programmed via Win512 version 2 7 x for the alarm points zones in question When only one zone or one zone address alarm point is in alarm status the c i e buzzer sounds 0 8 5 sec and there is a Co incidence alarm presentation in the display Note that LEDs Fire L1 are not indicating a co incidence alarm The co incidence alarm will be automatically Reset after 5 minutes i e if the zone alarm point is no
19. any external equipment s fault output User definable fault message programmed via Win512 80 Panasonic Eco Solutions Nordic AB MEW01473 17 2 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Fault acknowledge The LEDs Routing equipment Fault tx activated L13 and Fault Disablements General fault L9 are turned on LEDs Fault Disablements Alarm devices L11 System fault L7 and or Fault Disablements Fire brigade tx L12 might be turned on as well Output s for routing equipment Fault tx is are activated Output s for general fault is are activated Output s for general charge fault might be activated One or more fault messages incl date and time are shown in the control unit display If Fault latching is selected in Win512 version 2 7 x default after the time might be shown Serviced the fault is already serviced corrected Example Fault messages shown in the control unit display FAULT No reply zone 123 address 01 technical number 000025 2009 10 02 15 22 serviced FAULT No reply zone 123 address 03 technical number 000027 2009 10 06 09 25 FAULT No reply zone 234 address 01 technical number 002112 2009 11 06 15 25 Number of not ackn faults in system 5 e Login according to chapter Access page 98 e Use menu H6 access level 2B for fault acknowledge see chapter FAULT Acknowledge H6 page 142 Menu H6 is a l
20. be replaced The main board 5010 shall be replaced since more components are broken 66 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x as well BAVET ILS Oure e Koco Fuse F9 on the output unit p c b is blown DAUL Haei C rrene loga lt L54 sp CU sex Autronica interface board BS4 The current consumption is gt 60 mA on the BS4 loop PAUD lnaiGila Woltage Lae loogivc xs CU Autronica interface board BS4 The BS4 loop voltage is gt 16V normally it is 14V 0 1V FAVT ID aceuollic lalisjolleny Winslic somone The display unit is not the same type as programmed Change the programming or the unit An interlocking input is not activated within the time set for fault activation 5 255 seconds The time is counted from the activation of the output in the interlocking combination area AAA point PP PAUL S Internal short Clrouit COM loogo x Control UiMIie sox Short circuit on the connection ribbon cable to or between the expansion boards 458x in the control unit xx EBL512 G3 The key cabinet has been opened without a prior fire alarm i e if somebody has opened the key cabinet illegally or The key cabinet has not been closed within 5 minutes after reset of all fire alarms in the system 67 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United vers
21. cabinet fault is acknowledged the LED Fault Disablements General fault L9 will be turned off i e if the key cabinet is closed and if there are no other faults in the system Co incidence alarm A Co incidence alarm can be manually reset with the Reset button P3 on the c i e front or automatically reset after 5 minutes i e if the alarm point zone is no longer in alarm status See also chapter Co incidence alarm 2 address zone dependence page 47 Alarm Acknowledgement Facility AAF reset NOTE The AAF function is used in conjunction with an AAF Control which today is available on the Australian market only 52 Panasonic Eco Solutions Nordic AB MEW01473 16 8 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x The indication in the control unit display during the Acknowledgement Period 10 60 sec and the Investigation Period 0 3 min respectively will automatically disappear when e the AA process ends because no detector in the AAF zone is over the fire alarm level e the AA process ends up in a fire alarm which has higher priority Regarding Fire alarm reset see above Quiet alarm reset Quiet alarms are non latching i e they will be automatically reset when the alarm point zone is no longer above alarm level Outputs activated by quiet alarm will be de activated In some cases after a programmable delay time 53 Panasonic Eco Solution
22. convention and language If no text is shown the soft key has no function When Evacuate is not used this soft key may be used for Alert Annunciation acknowledge In the New Zealand convention it is used for Acknowledge alarm Silenced Alarm devices is indicated by the symbol rx to the right in this area The symbol area The symbol area is at the top of the display see 6 1 above The symbol area Symbol Indicating The door is open in any c i e or external FBP in the system See also page 36 Loss of mains in any c i e or ext power supply unit in the system i e the unit respectively is out of 230 V AC and is power supplied via batteries The week average sensor value is over the service level for one or more analog smoke detectors in the system See also page 124 Note that the symbol area may be suppressed see 6 3 22 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 6 3 The information area priority order When the control unit system is in normal operation quiescent state i e no fire alarms no faults no disablements no service signals no zones in test mode no activated interlocking in outputs and or Alert Annunciation function not enabled only the LED Operation L5 should be lit and some system information is shown in the control unit display However the system information has the lowest priority and more imp
23. documentation NOTE After the TLON Network installation download it is highly recommended to restart the control units Add a Control Unit in a TLON network When adding a control unit to a running installation you have to have the same software S W version in all control units Often the new control unit has a newer version than the existing control units Normally the latest version is the best to use i e the control units in the running installation have to be upgraded As an alternative it is possible to download an earlier S W version in the new control unit Both alternatives are described in chapter New system program S W version download page 89 Open the current project in TLON Manager add one control unit and install download it according to the separate TLON network documentation Also see 18 2 1 above Open the SSD for the current system via Win512 version 2 7 x Add one control unit and the units connected to it and download the new SSD according to chapter Programming SSD download page 87 Make two TLON networks one It is very important that two or more presentation numbers Zone or Zone Address in the systems are not the same The system properties have to be the same Use one of the systems e g the largest and add to it the control units etc from the other system If it is known from the beginning that two systems shall be one in the future it is possible to give the control units
24. equipment B10 De activate alert annunciation function Scroll to menu B4 B4 Re enable zone Re enable zone lo If there are no zones to re zone 002 enable menu B4 will be zone 006 shown again The disabled zone 073 zones will be shown in a list Use Y or A to select the zone or write the zone number and press lt Re enable zone loz Re enable another zone or zone 006 press ESC Scroll to zone 073 another menu or press ESC 108 Panasonic Eco Solutions Nordic AB MEW01473 25 5 n lt n Scroll to menu B5 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Re enable zone address H2 B5 Disabled alarm points zone addresses are listed in menu H4 U1 from which it is also possible to get a print out Alarm point s and or zones disabled via the Single reset with automatic disablement encapsulation function see page 51 have to be re enabled via this menu A zone will be displayed as ZZZ 00 i e zone number and address 00 Re enabling via this menu has higher priority than automatic re enabling When all zone addresses have been re enabled The LED Fault Disablements General disablements L10 will be turned OFF if there are no other disablements in the system Menu According to chapter Access see page 98 Scroll to menu H2 H2 Disable or re enable B2 Disable zone address Disable output Re enable zone Re enable zone address
25. fault L9 After the fault is acknowledged via menu H6 the LEDs will be turned OFF if there are no other faults After any restart required individual disablements have to be done Memory fault In case of a fault in the Main board 5010 S W system program or the MMI board 5011 S W the following fault message might be shown Not shown in the display only via Win512 version 2 7 x in other control unit in the system or via the Web server This is also indicated by LED System fault L7 and the buzzer sounds steady continuous The Fault tx output is activated A new download of the S W system programs are required and or the Main board and or the MMI board have to be replaced NOTE After SSD download see chapter Programming SSD download page 87 the following messages might be shown Checksum fault in downloaded data Control unit will now restart After restart 96 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x FAULT Restart control unit nn code xx address yyyyyyyyy This means that the SSD have not been correctly downloaded A new SSD download has to be performed 97 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 23 Access To use the key pad in the control unit to get access to the menu tree it is necessary to
26. given the same address Check the units Earth fault is detected in control unit no xx System voltage is normally 24 V DC 24 V to earth is normally 12 5 V O V to earth is normally 11 5 V Voltage to earth lt 3 4 V Earth fault minus 63 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Voltage to earth gt 18 3 V Earth fault plus Check all cables for damage etc The function of the control unit cannot be guaranteed Call for service personnel engineer Check all cables for damage etc connected to the unit FAULT Papansin looeuccl x COmicic l unit sox This is valid for the exp boards 4580 amp 4581 i e no x mounted in the control unit no xx There is some internal fault on the board which has to be replaced This is valid for the I O Matrix board 4582 no x connected on COM loop x 0 3 in the control unit no xx There is some internal fault on the board which has to be replaced PAVIE ExternallEBE x Board lt CU Sox The control unit i e the 1582 board cannot communicate with the ext FBP or data converter z Check the connections 7 Check the cable break Check the address DIL Switch in the ext FBP Is correct address set Several ext FBPs have the same address Faulty ext FBP The fault is to be found in the external power supply equipment which has a fuse fault output connected to
27. if the control expression trigger condition for the output respectively is fulfilled true the output will not be activated The outputs in one or more control units can be disabled or the outputs in all control units Disabled control outputs are indicated by LED Fault Disablements General disablements L10 and shown in menu H4 U1 from which it is possible to get a print out When all outputs have been re enabled The LED Fault Disablements General disablements L10 will be turned OFF if there are no other disablements in the system The outputs will be disabled until re enabled again via this menu Menu According to chapter Access see page 98 Scroll to menu H2 H2 Disable or re enable F Disable zone Disable zone address Disable output Re enable zone Re enable zone address Re enable output Disable re enable output type Disable re enable alarm devices Disable re enable routing equipment B10 De activate alert annunciation function Scroll to menu B7 B7 Disable re enable output type Select output type Use VW or A to select extinguishing the output type in the list ventilation and press contr exting vent _ See NOTE below 5 Including Addressable siren 3377 and Addressable sounder base 3379 112 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7
28. in conjunction with a fire alarm __ 46 15 6 Co incidence alarm 2 address zone dependence 47 15 7 Alarm Acknowledgement Facility AAF 48 15 8 Quiet alarm 48 16 Alarm reset 50 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 16 1 Pre warning reset 50 16 2 Fire alarm reset 50 16 2 1 All 50 16 2 2 Single 50 16 2 3 Single with automatic disablement 31 16 2 4 Acknowledged and Isolated alarm 51 16 3 Heavy smoke heat alarm reset 52 16 4 Alert Annunciation 52 16 5 Key cabinet alarm reset 52 16 6 Co incidence alarm 52 16 7 Alarm Acknowledgement Facility AAF reset 52 16 8 Quiet alarm reset 53 17 Fault 54 17 1 Fault messages 56 17 2 Fault acknowledge 81 18 Commissioning an installation 83 18 1 Single Control Unit 83 18 2 Control Units in a TLON network 84 18 2 1 TLON network installation 84 18 3 Adda Control Unit in a TLON network 85 18 4 Make two TLON networks one 85 18 5 Delete a Control Unit in a TLON network 85 19 Programming SSD download 87 19 1 Check All Loop Units 87 19 2 Single Control Unit 87 19 3 Control Units in a TLON network 88 19 4 User definable text messages download 88 20 New system program S W version download __ 89 20 1 Single control unit c 1 e 89 20 2 Control Units in a TLON network 91 21 Upgrade number of addresses 92 21 1 Control Units in a TLON network 93 22 Restart 94 23 Access 98 24 Perform monthly test H1 100 25 Disab
29. in the system respectively the final control unit numbers right from the beginning in order to get the correct technical numbers in the system documents NOTE Two or more presentation numbers Zone or Zone Address in the systems must not be the same Delete a Control Unit in a TLON network Physically disconnect the control unit This action will generate faults in the other control units Acknowledge the faults Open the current project in TLON Manager delete the control unit according to the separate TLON network documentation 37 It is not possible to merge two TLON Networks into one or copy one system and paste into another system 85 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Open the SSD for the current system via Win512 version 2 7 x Delete the control unit and the units connected to it and download the new SSD according to chapter Programming SSD download page 87 86 Panasonic Eco Solutions Nordic AB MEW01473 19 Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Programming SSD download 19 1 19 2 The PC program Win512 version 2 7 x is in a mixed system used for programming of the site specific data SSD and to download it into the EBL512 control unit s the EBL512 G3 control unit s and or the 1728 1735 1736 1826 amp 1828 display units When the units are running i e
30. is not correctly connected or is missing TLON connection board 1590 5090 No communication connection with the TLON network The board for the TLON Network in control unit no xx has to be replaced FAULT Wire to exting system control unit XX Short circuit cut off on the wires from the 1583 German Fire Brigade interface board in control unit No xx to the connected extinguishing system equipment This is valid for the I O Matrix board 4582 no x connected on COM loop x in the control unit no xx Check the board type set with jumpers JP4 and JP5 on the I O Matrix board The type should be the same as programmed via Win512 FAULT Wrong type expansion board x COmcic l Unit Sox Valid for the 8 zones exp board 4580 and the 8 relay outputs exp board 4581 mounted in control unit no xx Check the type of board which should be the same as programmed via Win512 version 2 7 x The unit is not the same type as programmed Change the programming or the unit 78 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x address xx technical number xXxxxxx Check the type of unit which should be the same as programmed via Win512 FAULT Zone line input technical number XXXXXX Detector mounted in an ADB 2330 faulty removed detector or Ext line input to an ADB 2330 break on a wire or wrong no end of line resistor
31. logon with an access code for level 2B or 3A See also chapter Access levels page 25 Open the door in the control unit level 2A press the soft key Menu P4 and continue as follows tl EBL512 G3 United United A mixed system Control Unit XX XX 00 29 User definable text User definable text year month date yyyy mm dd hh mm hour minute Menu A Enter the code 4 digits Access code The digits are replaced by ee In the display NO ACCESS The access code was not correct Try again The access code was correct A main menu list is displayed Press lt to H1 Perform monthly test accept menu H1 or scroll H2 Disable or re enable jump to the wanted menu H3 Set calendar and clock H2 H10 and press lt H4 Present system status H5 Service H6 FAULT Acknowledge H7 Perform ZONE TEST H8 Maintenance H9 Interlocking outputs and inputs H10 Change access code for daily duties Escape menu NOTE When the Russian Ukraine Australian or the New Zealand language is selected the date is shown as follows dd mm yyyy 98 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Explanations Action in the table use push button key e g Text in display in the table what is shown in the control unit c 1 e display Comments in the table Comments to the text in the Action and Text in displ
32. longer in alarm status or via the Reset button P3 See chapter Alarm reset page 50 Example Co incidence alarm zone 123 address 45 within zone 123 Co incidence alarm Zone Address T 23 45 SMOKE User definable alarm text for 123 45 If more than one Co incidence alarm not dependent on each other are activated the LEDs Alarms queued L6 are blinking and the Co incidence alarms will be automatically scrolled each 5 second If two or more zones or alarm points zone addresses dependent on each other are in alarm status at the same time normal fire alarm see above will be activated in the system The co incidence alarm function can be turned on off via a time channel 47 Panasonic Eco Solutions Nordic AB MEW01473 15 7 15 8 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Alarm Acknowledgement Facility AAF One or more Alarm Acknowledgement Facility Controls are used in the system See EBL512 G3 Planning Instructions chapter Alarm Acknowledge ment Facility AAF for more information regarding the AAF function During the Acknowledgement Period 10 60 sec the following information a list if many is shown in the c i e display AAF zone zz activated dd mm yyyy hh mm During the Investigation Period 0 3 min the following information a list if many is shown in the c i e display AAF zone zz investigation in progress dd mm
33. or Zone interface 2335 2226 input break on a wire or wrong no end of line resistor or Zone interface 2226 No ext power supply or Multi purpose I O unit 3361 monitored zone line input Z break on a wire or wrong no end of line capacitor short circuit if not programmed for fire alarm at short circuit FAULT Zone line input Zone xxx Address xx expansion board x Valid for the 8 zones exp board 4580 zone line input x xxx xx zone address The board is mounted in control unit xx Break on the zone line wrong no end of line device short circuit if not programmed for fire alarm at short circuit FAULT Zone line input zone xxx address xx technical number xxxxxx Valid for the Multipurpose I O unit 3361 monitored zone line input Z Break on the zone line or wrong no end of line capacitor 470 nF or short circuit if not programmed for fire alarm at short circuit Nocontact ivi thimeanni Board Shown only in the affected control unit e Check that EBL512 G3 type 5000 is selected in the SSD Control unit properties e Fault in the Main board 5010 software or hardware Check the cable between the Main board and MMI board This is a very 79 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x serious fault Call for service personnel engineer immediately Programmable input is connected to
34. page 56 NOTE Most of the faults have a delay Each control unit should be tested as follows Perform monthly test menu H1 Remove one battery fuse e g F2 on the Main board 5010 The following fault message is to be shown FAULT Battery not connected CU xx NOTE xx is depending on control unit xx 00 29 Put back the fuse and acknowledge the fault menu H6 Remove fuse F4 on the Main board 5010 The following fault message is to be shown FAULT Supervised output 0 CU xx NOTE xx is depending on control unit xx 00 29 Put back the fuse and acknowledge the fault Check the manual call points the glass Take required measures Use the manual call point test key to activate fire alarm Check some control outputs Are they activated according to programmed control expressions 168 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 35 How to change paper in the printer When the paper roll is almost empty a red line appears on one edge of the paper Change the paper roll before it is completely empty Always have a spare paper roll on site paper width 58 mm Change the paper roll as follows e Read all instructions before changing the paper roll e Open the control unit door e Open the printer cover i e press the green illuminated release button in the middle on top of the printer front e Remove the remains of the ol
35. red optical indicator lamp External Indicator LED A unit with an LED Connected to an ASB CDB or a detector with a built in LED Old installations Also connected to an ADB Lit when the built in LED is lit Display LCD LCD Liquid Crystal Display Display in the c i e or Display unit for presentation of fire alarms fault messages etc a graphical monochrome LCD 320 x 240 dots and backlight Door open Door Key switch In EBL512 G3 there is a door switch which is activated when the control unit door is open In some other units this door switch is replaced with a key switch 11 Panasonic Eco Solutions Nordic AB MEW01473 2 17 2 18 2 19 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x When the door is open a message Door is open in this unit is shown in the LCD Site Specific Data SSD The SSD is unique for each installation All alarm points presentation numbers user definable text messages programmable outputs etc are created in the PC program Win512 version 2 7 x and also downloaded in EBL512 G3 United version 2 7 x with Win512 version 2 7 x Software S W System program The S W makes the control unit the microprocessor work It is factory downloaded but a new version can be downloaded in EBL512 G3 on site Mixed system EBL512 units 1548 1549 1550 with software EBL512 version 2 7 x together with EBL512 G3 units 5000 5001 wi
36. something is wrong in the downloaded SSD PAULE SSI external l presentation Unit Sox expansion board x Controlunit xx EPU 1728 There is no SSD Site Specific Data downloaded to the unit or something is wrong in the downloaded SSD FAULT Site specific data fire brigade penel ssy Exo Board K COnmcroll Wine sex FBP 1826 1828 There is no SSD Site Specific Data downloaded to the unit or something is wrong in the downloaded SSD 76 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x If the output is programmed for sounders type Alarm devices itis also indicated by LED Fault Disablements Alarm devices blinking If the output is programmed for fire brigade tx type Routing equipment it is also indicated by LED Fault Disablements Fire brigade tx blinking 512 x 0 SO Short circuit break on the connected cable equipment and or blown fuse F5 or F6 on the connection board x 1 S1 Short circuit break on the connected cable equipment and or blown fuse F7 or F8 on the connection board x 2 S2 Short circuit break on the connected cable equipment x 3 S3 Short circuit break on the connected cable equipment e Connected equipment might be stolen e Resistor s missing or not correct value see dwg 512 42 512 G3 x 0 SO Short circuit break on the connected cable equipment and or blown fuse F4
37. system EBL512 G3 United version 2 7 x 25 9 Disable re enable routing equipment H2 B9 Disabled outputs are listed in menu H4 U1 from which it is possible to get a print out Outputs for routing equipment fire brigade tx fault tx can be disabled and re enabled via this menu Can be useful during an installation and test period when only local alarms are required Disabled output is indicated by LEDs Fault Disablements General disablements L10 and Fire brigade tx L12 Disabled output will stay disabled until re enabled again via this menu Menu According to chapter Access see page 98 Scroll to menu H2 H2 Disable or re enable Disable zone Disable zone address Disable output Re enable zone Re enable zone address Re enable output Disable re enable output type Disable re enable alarm devices Disable re enable routing equipment B10 De activate alert annunciation function Scroll to menu B9 B9 Disable Re enable routing equipment Routing equipment for Fire Use Y or A to select Fault output type s De aa Press Disable or Re enable Blank space Escape menu Disable or Re Routing equipment for Fire Disable or Re enable enable Fault another output type or Fire and fault press ESC Scroll to another menu or press Blank space ESC Escape menu DIRELG RERET 116 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm
38. system EBL512 G3 United version 2 7 x Service mode loop of board 0 CU 00 Write BS4 loop number B Direction board number and EBL512 control unit number then select A direction or B direction Press lt 4 E g BS4 loop 3 Service mode CU 03 board 0 loop 3 Press 4 ESC or Esc board 0 CU 03 Supplied from A direction menu to leave the menu and A and terminate the service direction Escape mode lt menu 2d or ESC A8 Service mode for BS4 loop Scroll to another menu or press ESC 140 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 28 10 Display current consumption on BS4 loop H5 A9 NOTE The following is valid only for an EBL512 control unit with one or more BS4 boards 1584 If the control unit number CU XX is valid for an EBL512G3 control unit this menu is not valid The current consumption an average value for each BS4 loop can be displayed NOTE The resolution is not very high i e the displayed values give only a rough idea of the current consumption A very small current consumption cannot be presented correctly precisely Text in display Comments Menu According to chapter Access code for service and maintenance H5 and H8 see page 129 nae Sensitive fault detection mode Service mode for COM loop Display current consumption in unit Display current consumption on COM
39. to download the SSD until the TLON Network installation is ready In TLON Manager do the TLON Network programming for the project i e only the control units that shall be connected now When the TLON Network installation see below is ready download the SSD Later when one or more control units shall be added to the TLON Network Open the project in TLON Manager add the control unit s and install download it according to the separate TLON network documentation Open the SSD in Win512 version 2 7 x and add the control unit s and download the SSD to all control units TLON network installation A project a system with two or more control units is created in the PC program TLON Manager or has been created earlier A PC is connected to the modular connector J10 Network no 0 in the control unit main board 5010 Open the project in TLON Manager 35 In a mixed system see chapter Mixed system page 12 the EBL512 c i e has to have the software version 2 7 x and the EBL512 G3 c i e has to have the software EBL512 G3 United version 2 7 x 3 The TLON connection board is mounted on the main board 5010 Network cable connections are made on the main board 5010 terminal block TA 84 Panasonic Eco Solutions Nordic AB MEW01473 18 3 18 4 18 5 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x and install download the project see separate TLON network
40. type elWeleleye Use A or V to BS4 loop select a type and press Zone line input mers Addr zone interface Disconnect COM loop Write the required data or COM loop of control unit 00 use A or V to select and press lt Depending on the selected type the following will be shown eee Disconnect zone line input Zone line input of exp board 0 control unit 00 Disconnect addressable zone interface Input technical number fooo00 145 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Disconnect type 0 meoo Continue to disconnect or BS4 loop press ESC to menu S1 Zone line input Addr zone interface S1 Disconnect loop zone line input LED Fault Disablements General disablements L10 will light up Scroll to another menu or press ESC Don t forget to re connect the loop zone line again via menu H8 S2 146 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 31 3 Re connect loop H8 S2 Disconnected disabled loops zone lines via menu H8 S1 are indicated by LED Fault Disablements General disablements L10 and listed in menu H4 U1 NOTE When you re connect a COM loop all the statistics shown in menu H5 A6 will be erased and set to 0 When all loops zone lines have been re enabled The LED Fault Disablements
41. unit no xx FAULT No connection with MMI board GOmcieoll Unit sx This fault message cannot be shown in the control unit s display only via Win512 version 2 7 x via Web server and in other control units in the system Fault in the MMI board 5011 software or the MMI board Check the cable between the boards This is a very serious fault Call for service personnel engineer immediately FAULT No reply expansion board x COMcerOl Unit xx 70 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Valid for the 8 zones exp board 4580 and the 8 relays exp board 4581 mounted in the control unit no xx e EBL512 G3 cannot communicate with the board Check change the address Check the cables connections e Check if the Main board fuse F13 is broken Fuse T4A L 250V TRS This is valid for the I O Matrix board 4582 no x connected on COM loop x in the control unit no xx Check the board s address i e the I O Matrix board no Jumpers JP1 JP2 and JP3 on the board Check if the board is disconnected from the loop In spite of the control unit is communicating in both directions one or more units cannot be found e Check the unit s address DIL Switch in some unit or with programming tool 3314 in some units e Faulty unit e Detector removed from its base e Double break on the COM BS4 loop Note Single break gives the fault
42. when a whole zone is disabled the addressable manual call points will not be disabled for safety reasons This function can depend on convention country Up to 512 whole zones can be disabled via menu H2 B1 Up to 200 alarm points zones address can be individually disabled via menu H2 B2 and or COM loops zone interface inputs and or MIO inputs can be disabled via menu H8 S1 Alarm points disabled via time channels are not limited and must not be counted Up to 200 outputs can be individually disabled via menu H2 B3 Disabled output will stay in or return to the normal condition for the output respectively Collectively disabled outputs via menus H2 B7 B9 are not limited and must not be counted Up to 200 Interlocking outputs can be individually disabled via menu H9 C4 It is not possible to exceed the limits A warning will be shown Max disablements reached Disablement not performed Don t forget to re enable via menus H2 B4 B9 H8 S3 H9 C5 or use automatic re enablement for zones and alarm points Disablements are indicated by LED Fault Disablements General disablements L10 and are also shown in the display An example Zone 001 disabled yyyy mm dd hh mm Zone 002 address 01 disabled yyyy mm dd hh mm Number of disablements in system 2 NOTE See chapter The information area priority order page 23 regarding priority order Disablements and faults are indicated by a 2 sec bee
43. xx 00 29 Check fuse F9 F10 F11 and F12 respectively on the Main board 5010 in control unit no xx Fuse T4A L 250V TRS 512 Check the fuses F1 and F3 on the connection board 1555 Supervised output S3 is in some conventions configurations 57 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x supplied via F1 and F3 Indicated by LED L15 blinking in EBL512 and LED Fire brigade tx L12 blinking in EBL512 G3 512 G3 Power supply output 0 J3 3 4 xx 00 29 Check fuse F8 on the main board 5010 in control unit no xx Also indicated by LED Fault Disablement Fire brigade tx L12 blinking Fuse T500mA L 250V TRS This is valid for the external power supply 3366 connected on the COM loop The output might be turned off or the current output limit 4A is exceeded FAULT Alert annunciation unit xx COmccol unit sox 1735 1736 Alert Annunciation Unit AAU The AAU unit xx connected to control unit no xx is programmed as another type in the SSD or a fault in the unit FAULT Alert annunciation unit xx expansion boarde Cominco ini sox AAU 1735 1736 The unit is programmed as another type of unit than the SSD says or fault in the unit PAURE Alarm tiout 1560 boar x CU rex The zone line input x on the 1580 board placed in control unit xx master is used for a single slave unit control unit or seve
44. 0 Change code for PC communication Scroll to menu S8 S8 TE the control units ane Start synchronization Press Y i e select Yes Yes Press lt 4 to start the synchronization to be cont on the next page 158 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Synchronization in progress During the synchronization the progress symbol for each CU00 CU10 u control unit is shown CU01 CU11 0 In the example are CUIS amp CU02 CU12 CU16 not programmed CU03 CU13 CU04 CU14U CU05 CU06 CU07 CU08 CU09 Escape menu After a few minutes Synchronization completed Date and time for the latest yyyy mm dd hh mm completed synchronization CU00 v CU10 v The symbol v means that CU01 v CU11 v the synchronization CU02 v CU12v succeeded CU03 v CU13 v If the symbol v is missing CU04 v CU14 v CU05 v CU06 v CU07 v CU08 v CU09 v Escape menu S8 Synchronize the control units Scroll to another menu or press ESC the synchronization has failed 159 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 31 10 Change code for service maintenance H8 S9 For security reasons the default code should be changed Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page
45. 0 De activate alert annunciation function Scroll to menu B6 B6 Re enable output Re enable output type Select output type S 3361 3364 also used for R RU4 SU4 outputs conn to Expansion board EBL512 S CU voltage output S0 S3 R CU relay output RO R1 Press lt to accept Re enable loooo1 output 0 If there are no outputs to ea on the 000001 output 1 re enable menu B6 will be selected type the shown again i i Re enable control unit 90 SO sow Ine ithe o Use Y or A to select shown control unit 00 S1 l the output in the list or Re enable control unit fo RO write the output and press control unit 00 R1 a Re enable CU do exp board 0 output O CU 00 exp board 0 output 1 110 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Re enable output type SKIAIRRIZ Re enable another output S or press ESC Scroll to R another menu or press Expansion board ESC 111 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 25 7 Disable re enable output type H2 B7 All outputs programmed as type control general fire ventilation and extinguishing system can for the type respectively be disabled all at the same time or all outputs of these types can be disabled all at the same time Disabled control output means that even
46. 2 7 x r Download completed Restart control unit Click Yes and the control unit will restart Regarding the restart see also chapter Restart page 94 6 LED Operation L5 will be turned on and the other LEDs will be turned off 20 2 Control Units in a TLON network All control units connected to a TLON network shall have the same software version For download of new software in each control unit follow the procedure described above Since some control units do not have contact with some control units during the downloading the following faults might be generated FAULT Control unit xx has no contact with control unit xx network x yyyy mm dd hh mm FAULT CU xx has wrong information yyyy mm dd hh mm The faults have to be acknowledged 91 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 21 Upgrade number of addresses All EBL512 G3 settings are normally factory downloaded before delivery An EBL512 G3 control unit in a mixed system can be configured for 128 256 or 512 addresses i e not alarm points as in a normal EBL512 G3 control unit On site it is possible to upgrade the maximum number of addresses 128 gt 256 gt 512 but it requires a special sequence of actions e Use WinG3 version 1 1 x to download the normal software i e EBL512 G3 version 1 1 x See the chapter New system program S W versi
47. 3 16 4 16 5 16 6 16 7 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Heavy smoke heat alarm reset If a heavy smoke heat alarm has been activated it will be reset at the same time as the corresponding fire alarm is reset Also the output s will be reset i e de activated Alert Annunciation Regarding the function see chapter Alert Annunciation alarm AA alarm page 45 and EBL512 G3 Planning Instructions chapter Alert annunciation Reset of the AA alarm s can be done via push button Reset on an AA unit 1735 1736 or an AA controller 1740 or in the c i e NOTE Reset via an AA unit is possible only during the investigation time and of AA alarm s only not normal fire alarms If more than one AA alarm is activated they will be reset all at a time Key cabinet alarm reset A key cabinet alarm has to be reset like the normal fire alarms After reset a fault message is shown in the display to inform the user that the key cabinet has been opened FAULT Key cabinet control unit xx yyyy mm dd hh mm NOTE The date is for the Australian New Zealand Russian and Ukrainian languages shown as dd mm yyyy xx control unit number 00 29 If the key cabinet is closed again the status information is changed to serviced This key cabinet fault message is to be acknowledged the same way as normal faults see chapter Fault acknowledge page 81 When the key
48. 3 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Push buttons Keypad on the Control Panel CP Key push button Operation function 4 Enter Used to log on i e to get access to the menu tree via an access code and to accept a menu and accept input of data Also used by fault signal and service signal to acknowledge the selected fault analog smoke detector Left right keys are used to move the cursor in a menu Up down keys are used to scroll between the menus 1 9 and 0 Numeric key pad for the digits 0 9 Can be used to input data and in the menu system to jump to a menu with a corresponding number e g 5 for a jump to menu H5 DEL Used to clear delete all visible entry fields ESC Used to stop input of data or to step one step up in the menu system e g from a sub menu to the main menu NOTE To leave the menu system use the soft key Escape menu P4 21 Panasonic Eco Solutions Nordic AB MEW01473 6 Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x The display LCD 6 1 Symbol area Information area Soft key area 6 2 Areas in the display Next zone e Symbol area Some events are indicated with symbols see 6 2 below e Information area General area for all kind of information and the menu system e Soft key area The function of the soft key respectively is shown here i e it will vary depending on the situation
49. 4 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 25 2 Disable zone address H2 B2 Addressable alarm points also addressable manual call points connected to the COM loop can be individually disabled Disabled alarm points zone addresses are listed in menu H4 U1 from which it is also possible to get a print out Regarding disabled analog smoke detector The sensor values for a disabled analog smoke detector will not be saved i e only the values saved before and after the disablement will be used when calculating the week average sensor value Disabled alarm points zone addresses have to be re enabled via menu H4 B5 Menu According to chapter Access see page 98 Scroll to menu H2 H2 Disable or re enable n lt Tal Disable zone address Disable output Re enable zone Re enable zone address Re enable output Disable re enable output type Disable re enable alarm devices Disable re enable routing equipment B10 De activate alert annunciation function Scroll to menu B2 B2 Disable zone address a Disable zone loo address 00 press lt Write zone number and_ Disable zone 001 address of Press to disable the address e g 001 press lt and 01 Re enable time HER Press to disable without automatic re Yes enablement Default is current time 3 hours or Accept the time 3 hours
50. 5 s H 15 Low sensitivity 3 6 m amp Normal detection 15 s L 15 Normal sensitivity 3 m amp Slow detection 35 s N 35 High sensitivity 2 4 m amp Slow detection 35 s H 35 Low sensitivity 3 6 m amp Slow detection 35 s L 35 Heat algorithm Class A1 Al Heat algorithm Class A2 S A2 Heat algorithm Class B S B Decision algorithm Dec Default is N 15 and A1 respectively 53 If some other short name is wanted it can be changed in Win512 version 2 7 x Up to six characters can be used Analog multi detector 4300 only 123 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 27 5 Sensors activating SERVICE signal H4 U5 When SERVICE signal is generated in the system following symbol is shown in the display s symbol area Ly Regarding the SERVICE signal levels see Planning Instructions chapter SERVICE signal Menu H4 US is a list of the sensor s activating SERVICE signal NOTE SERVICE signal is only information that the sensor has to be replaced with a new clean sensor soon The SERVICE signal has to be acknowledged see chapter Error Reference source not found page 149 Menu According to chapter Access see page 98 Scroll to menu H4 H4 Present system status v U1 Disablement U2 Disablement by time channel U3 Open doors U4 Sensor values U5 Sensors activating SERVICE signal U6 Event l
51. 6 Event log U7 Information Scroll to menu U6 U6 Event log Select event log Use Y or A to select Interlocking log alog E g the Alarm General event log log a When lt is pressed the events will be shown in the A dynamic list in which display The most recent event is on top of the list you can scroll with Y or Some examples are shown below A Reset all alarms If printer is mounted the 2009 12 03 09 25 30 soft key Print will be visible else not Press FIRE ALARM zone 123 address 45 Print to select and print 2009 12 03 09 09 15 the events the latest hour day week or month FIRE ALARM zone 123 address 46 Scroll with Y or A to 2009 12 03 09 07 01 view more events If there are no events in the list when lt is Event 15 to 13 of 21 pressed the list view will Escape not open menu ESC U6 Event log Scroll to another menu or press ESC NOTE During printing Print will be replaced with Abort printing 125 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 27 7 Show information H4 U7 Menu H4 U7 can be used to show the following information for the specific control unit you currently use Main board version The S W system program version of the Main board 5010 e g United version 2 7 x MMI board version The S W system program version of the MMI board 5011 e g United version 2 7 x Max num
52. 8 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Commissioning an installation 18 1 Before you connect the power supply to a control unit all other cable connections shall be made Check once more that they are correct Single Control Unit 1 Take away the rectifier fuse F1 and the battery fuse F2 on the main board 5010 NOTE In a single standalone control unit there shall be no TLON connection board 1590 5090 plugged on the main board Connect the batteries to the main board 5010 terminal block J2 NOTE There shall be an in line fuses F on the cable between the batteries see drawing 512 G3 21 CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE DISPOSE USED BATTERIES ACCORDING TO THE INSTRUCTIONS Connect the rectifier to the mains 230 V AC NOTE It shall be connected to a household removable fuse for the fire alarm c i e only via a two way circuit breaker The mains cable shall be securely clamped and the wires shall be as short as possible The mains safety earth ground shall however be longer than the other wires to ensure that it is the last to be disconnected if the mains cable clamp should fail The lid protecting the screw terminals shall after the installation be correctly applied First replace the battery fuse F2 and then the rectifier fuse F1 on the main board 5010 LED Operation L5 indicate that the 24 V DC powe
53. Activate interlocking output 27 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 7 4 Access level 3A After the door has been opened Door open symbol in the symbol field the service maintenance personnel have access to level 2A and after access code for level 3A access to the following menus A6 Display statistics for communication A7 Activate address setting mode for DU S10 Change code for PC communication S5 Test of alarm devices 7 5 Access level 3B Used by Service maintenance commissioning engineers when a PC i e Win512 version 2 7 x is to be connected to EBL512 G3 for backup upload and download of site specific data SSD 7 6 Access level 4 Used by manufacturer or by personnel authorised by the manufacturer when a PC is to be connected to the control unit i e when Win512 version 2 7 x shall be used 28 Panasonic Eco Solutions Nordic AB MEW01473 8 Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Silence Alarm devices 8 1 In the control unit front the FBP part there is a push button Silence alarm devices P2 When the alarm devices are activated sounding and the push button Silence alarm devices is pressed the following will happen Px is shown in the display i e to the right in the Soft key area e The activated outputs programmed for sounde
54. C3 Reset interlocking output C4 Disable interlocking output C5 Re enable interlocking output Scroll to menu C2 C2 Activate interlocking output vag Activate interlocking output Write the area number and area oo point 00 point d press Press C2 Activate interlocking output Scroll to another menu or press ESC 163 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 32 3 Reset interlocking output H9 C3 All activated interlocking outputs are listed in this menu If the interlocking output is activated via its programmed control expression and with latching output selected in Win512 version 2 7 x the output has to be reset via this menu If the interlocking output is activated via its programmed control expression and with latching output not selected the output can be reset via this menu If the interlocking output is activated via menu H9 C2 the output has to be reset via this menu Text in display Comments Menu According to chapter Access see page 98 Scroll to menu H9 H9 Interlocking outputs and inputs a Scroll to menu C3 n lt n a reset alt ESC C1 Activated interlocking outputs inputs C2 Activate interlocking output C3 Reset interlocking output C4 Disable interlocking output C5 Re enable interlocking output C3 Reset interlocking output Reset interlocking
55. Display current consumption in unit Scroll to another menu or press ESC During the battery capacity check the voltage is measured with and without a resistor A difference between these two voltages gt 700 mV will result in a Low battery capacity fault 134 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 28 6 Display current consumption on COM loop H5 A5 The current consumption an average value for each COM loop can be displayed NOTE No or very small current consumption lt 10 mA cannot be presented correctly precisely Text in display Comments Menu According to chapter Access code for service and maintenance H5 and H8 see page 129 a Sensitive fault detection mode Service mode for COM loop Display current consumption in unit Display current consumption on COM loop Display statistics for communication Activate address setting mode for DU Service mode for BS4 loop Display current consumption on BS4 loop Scroll to menu A5 A5 Display current consumption on COM loop a Display current consumption on Write loop number and COM loop of control unit 00 control unit number and press lt press lt 0 If the control unit don t exist or don t answer Current consumption on COM loop 0 control unit The current consumption 00 is xxxx mA accuracy is 5 mA 2 or ESC A5 Display current consumption on
56. FAULT Restart control unit nn code 03 YYYY MM DD HH MM 38 NOTE The PC can only be connected to an EBL512 control unit i e not to an EBL512 G3 control unit 3 After SSD download the control unit will restart A number of faults might then be generated e g due to not connected units This will cause heavy traffic on the network which might affect delay the SSD download to the other units 87 Panasonic Eco Solutions Nordic AB MEW01473 19 3 19 4 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x If the download was not ok another fault will be generated FAULT Site specific data SSD CU nn YYYY MM DD HH MM This text message means that the SSD have not been downloaded properly i e a new download has to be performed Control Units ina TLON network The SSD for all control units can be downloaded via a PC Win512 version 2 7 x connected to one EBL512 control unit The download will be performed to the control units one at a time according to the chapter Single Control Unit above The download is performed in a consecutive order i e 0 1 2 3 4 29 amongst the selected control units but the control unit where the PC is connected will automatically be the last one to get the SSD downloaded When the SSD download to a control unit is completed that control unit will automatically restart see chapter Restart page 94 User definable text messages download
57. Flash ROM might be empty or the stored data might be old not valid 155 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 31 8 Activate address in alarm mode H8 S7 One alarm point zone address not a whole zone can be set in alarm The built in LED in the alarm point detector will be turned on to indicate the alarm NOTE All outputs standard and programmable which would have been activated by a real fire alarm from the same alarm point will now also be activated Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page 129 S2 Re connect loop zone line input S3 Acknowledge SERVICE signal S4 Clear weekly average S5 Test of alarm devices S6 Safe shut down of control unit S7 Activate address in alarm mode S8 Synchronize the control units S9 Change code for service maintenance S10 Change code for PC communication Scroll to menu S7 S7 S7 Activate address in alarm mode address in alarm mode be aed Select zone oo address 00 Write the zone number and press address e g 123 45 Press lt to start the fire alarm 156 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x First alarm 123 45 Alarm number 1 of 1 This manually activated Test mode fire alarm will be presented in all contro
58. General disablements L10 will be turned OFF if there are no other disablements in the system Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page 129 S2 Re connect loop zone line input S3 Acknowledge SERVICE signal Clear weekly average S5 Test of alarm devices S6 Safe shut down of control unit S7 Activate address in alarm mode S8 Synchronize the control units S9 Change code for service maintenance 10 Change code for PC communication Scroll to menu S2 S2 Re connect 52 Re connect loop zone line input zone line input oe Re connect type e NETeleys Use A or W to BS4 loop select a type and press Zone line input a Addr zone interface a Re enable COM loop a control unit 00 Write the required data and Ty i Depending on the press selected type the following will be shown Re enable zone line input Zone line input of exp board 0 control unit 00 Re enable addressable zone interface Input technical number flooo00 Re connect type e ieleleye Continue to re connect or BS4 loop press ESC to menu S2 147 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Zone line input Addr zone interface ESC S2 Re connect loop zone line input Scroll to another menu or press ESC 148 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instruction
59. Panasonic Operating Instructions MEW01473 Revision Fire Alarm System EBL512 G3 United version 2 7 X Author Jan Pettersson Date of issue 2012 04 05 Date of rev This page has deliberately been left blank Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Table of contents 1 Introduction 7 2 Definitions Explanations 9 2 1 PEWN AB 9 2 2 Alarm points 9 2 2 1 Smoke detector 9 2 2 2 Sensor 9 2 2 3 Analog detector 9 2 2 4 Analog Sensor Base ASB 9 2 25 Conventional detector 9 2 2 6 Conventional Detector Base CDB 9 2 2 7 Addressable 9 2 2 8 Conventional zone line input External line 10 2 3 Output unit 10 2 4 Output Control output 10 25 Short circuit isolator ISO 10 2 6 Display unit DU 10 2 7 COM loop 10 2 8 Control Unit C U C LE 10 2 9 Fire Brigade Panel FBP 10 2 10 Control panel CP 10 2 11 System 11 2 12 Network TLON LonWorks Echelon Node TLON Conn board Gateway Sub net Backbone net Router Repeater 11 2 13 LED 11 2 14 External Indicator LED 11 2 15 Display LCD 11 2 16 Door open Door Key switch 11 2 17 Site Specific Data SSD 12 2 18 Software S W System program 12 2 19 Mixed system 12 3 Overview 13 3 1 The EBL512 G3 system 13 3 1 1 Printer 13 3 1 2 Expansion boards 13 3 1 3 Power supply 14 3 2 S W versions 14 3 3 Documents 14 3 4 Applications 14 3 5 PCS W 14 3 5 1 Wi
60. SSW Win512 version 2 7 x Warm restart Automatically after download of FFD WASV SSD 00 alt 03 S W via a PC amp Win512 version S W SSW 2 7 x Cold restart Automatically due to external FFD WASV SSD 01 02 alt disturbance Cold restart S W SSw 04 20 NOTE During the restart the fault output relay for the Fault tx will be activated the supervised 24 V DC outputs SO S3 will be not supervised and SO S3 programmed as normally high will be low for a few seconds During the restart no fire alarm can be activated and the following is shown in the display Both rectifier mains and battery disconnected a If in the middle of a process also the SSW might be deleted a 7 The old S W will be deleted 48 Tf this happens call for service personnel engineer Depending on the restart reason also the SSW might be deleted 95 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x And after a few seconds if everything is all right else see Memory fault below A fault will be generated and the following text message will be shown in the display and the buzzer will sound FAULT Restart control unit nn code xx address yyyyyy Regarding code xx and address yyyyyy see page 73 This fault is also indicated by LEDs Routing equipment Fault tx activated L13 and Fault Disablements General
61. able text message the alarm text for fire alarm is shown if programmed Example pre warning zone 123 address 45 within zone 123 Pre warning Zone Address 123 49 sue User definable alarm text for 123 45 SMOKE after the presentation number is automatically added depending on the type of alarm point i e SMOKE HEAT MULTI or MCP NOTE The text Menu P4 is visible in the display only if the door in the CU is open If more than one pre warning is activated the LEDs Alarms queued L6 are blinking and the pre warnings will be automatically scrolled each five seconds Pre warnings are automatically reset see chapter Alarm reset page 50 15 2 Fire alarm The system can handle up to 15360 fire alarms but only 512 fire alarms can be shown in the c i e display If more than 512 fire alarms are activated no more fire alarms will be shown until one or more of the first 512 fire alarms are reset Outputs programmed for General pre warning and outputs programmed for the activated pre warning s 40 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x It is possible to have Selective alarm presentation i e only fire alarms from selected control units will be presented Set in Win512 Normally all fire alarms will be presented in all control units See also chapter The information area priority order page 23 In
62. accordance with the EN54 2 standard the following happens in case of a fire alarm e The buzzer in the c i e sounds 0 4 sec each 0 4 sec 0 4 0 4 sec e LEDs Fire L1 are blinking 0 4 0 4 sec e Output for routing equipment Fire brigade tx and outputs type Routing equipment are activated e Outputs for fire alarm are activated e Inthe c i e display a presentation number zone address is shown for the first fire alarm e Inthe c i e display a user definable text message alarm text is shown if programmed e Inthe c i e display is also some additional information presented One alarm point activating fire alarm Example fire alarm zone 002 address 03 within zone 002 First alarm 002 03 Alarm number 1 of 1 Zone Address 002 03 svo User definable alarm text for 002 03 After the presentation number is automatically added SMOKE HEAT MULTI or MCP depending on type of alarm point 20 In case of Selective alarm presentation only for the selected alarms Outputs programmed for General fire alarm and outputs programmed for the activated fire alarm s 41 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x More than one alarm point activating fire alarm Example fire alarm in zone 002 address 03 within zone 002 and nine other fire alarms of which the latest alarm is 003 11 in four d
63. ade panel xx expans on loogsccl CON rO UNE sox Alert Annunciation Unit 1735 1736 External Presentation Unit 1728 External Fire Brigade Panel 1826 1828 e The contact with the unit is interrupted Check the cable all connections and the 1587 board Is correct complete SSD downloaded via Win512 Check the address setting 1587 board the unit SW mode setting etc If there is a program memory fault in the unit there will be a fault message in the unit s display Memory fault in program area n n l or 2 The unit will not work PAUE OME OUNS WMI SKK e Fault in the output unit RAM e Fault in the output unit EPROM e Fault in the output unit EEPROM site specific data Replace the output unit output unit p c b FAULT Printer COntrol unit sox 72 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x This is valid for an EBL512 G3 type 5000 with printer Control unit no XX e Faulty printer e Printer not correctly connected e No paper SSW the data that is changed during operation i e week average sensor values not for 512 G3 access codes calibration values and event logs in control unit no xx e If the C U was made powerless i e mains and battery disconnected without first doing a Safe shut down of control unit via menu H8 this fault might be generated when the C U is powered again After fault acknowledge t
64. age shows the isolator just before the break in the A direction incl the following isolator There will also be shown FAULT Multiple ew eS oi NOTE Each 10 minute a check is performed if all short circuits are corrected repaired If so the communication automatically returns to communicate in the A direction only FAULT site specific data ssp control 3 NOTE The fault has to be acknowledged i e and it can last up to 10 minutes after the acknowledgement before the communication returns to communicate in the A direction only 75 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x The Site Specific Data SSD in control unit no xx is not downloaded correctly a checksum fault etc A new SSD download via Win512 is required BAULI S Site specifie data al annunciation unit xx Control FAULT Site specific data external presentation Unic SX COMcicOl unit sox BAULIS Site soecilric daca rire brigade J Erol Umie xx Alert Annunciation Unit 1735 1736 Ext Presentation Unit 1728 Ext Fire Brigade Panel 1826 1828 There is no SSD Site Specific Data downloaded to the unit or something is wrong in the downloaded SSD WAUIMES SSD alere EiMiINUIMCLEVELGiM Wine sox expanso lon boardi x Centro llunie sox AAU 1735 1736 There is no SSD Site Specific Data downloaded to the unit or
65. al fire is detected as soon as possible That s why more and more automatic fire alarm systems are installed In an automatic fire alarm installation especially if smoke detectors sensors are used everybody in the building needs to be informed how to avoid so called unnecessary nuisance fire alarms To avoid trouble and unnecessary expenses there are a couple of things to bear in mind Here are some advices and tips Tobacco smoke The detectors sensors cannot sense the difference between smoke and smoke They cannot separate tobacco smoke from smoke from a fire Intensive tobacco smoking in conjunction with bad ventilation can cause a fire alarm Welding grinding cutting sawing amp drilling These kind of jobs cause smoke Carpet welding Welding of plastic carpets causes a smoke that can be almost invisible but it still influences the smoke detectors sensors Cooking fumes toasting amp candles It is not only normal smoke that influences smoke detectors sensors It is all kinds of combustion products caused by cooking frying grilling toasting etc Warning Be careful when smoke detectors sensors are mounted near close to such activities Special environments In certain premises a special environment can exist which can influence smoke detectors sensors and cause alarm It can be ions from plastics flour dust oil haze aerosols strong perfumes strong ventilation insecticides disinfect
66. alues sensor values for each detector individually All evaluations and decisions are then made in the c i e Analog detectors are addressable an address setting tool is used for detector types 33xx 430x An analog detector has to be plugged in an analog sensor base ASB Analog Sensor Base ASB A sensor is plugged in an ASB which is connected to a COM loop see below Conventional detector Detector with only two statuses i e normal and fire alarm The detector contains a closing contact and a series alarm resistor Normally plugged in a conventional detector base CDB see below connected to a conventional zone line input with an end of line device Some types are connected directly on zone line Conventional Detector Base CDB A conventional detector is plugged in a CDB connected to a conventional zone line input Addressable A unit with a built in address device i e each unit is individually identified handled and indicated in the c i e The unit can be an I O unit with a zone line input to which one or more conventional alarm points can be connected Panasonic Eco Solutions Nordic AB MEW01473 2 2 8 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Conventional zone line input External line Input intended for one or more conventional alarm points End of line device in the last alarm point
67. and time in menu H3 118 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 27 Present system status H4 If printer 5058 an option for control unit 5000 is mounted it is possible to get a print out from some of the menus In this case the soft key Print P5 shall be used NOTE During printing Print will be replaced with Abort printing When Abort printing is pressed the soft key text immediately changes back to Print but the items already stored in the buffer will be printed up to five items Disablement H4 U1 This is a dynamic list of all disablements in the system Also alarm Single reset with automatic 27 1 point s and or zones disabled via disablement see page 51 are shown in the list In this case a zone 2 ss Scroll to menu H4 n lt n will be displayed as ZZZ 00 i e a zone number and address 00 Disablements by time channels are listed in menu H4 U2 According to chapter Access see page 98 H4 Present system status Pll U1 Disablement U2 Disablement by time channel U3 Open doors U4 Sensor values U5 Sensors activating SERVICE signal U6 Event log U7 Information When lt is pressed the disablements will be shown in the display Some examples Zone XXX address XX disabled yyyy mm dd hh mm Zone XXX is disabled yyyy mm dd hh mm Automatic re enabl Alarm points are disab
68. at all LEDs light up Press J The buzzer in the C U sounds and all dots in the display are shown All All dots are visible LEDs light up incl LEDs in units connected via I O Matrix board 4582 If printer 5058 an option for control unit 5000 is mounted it will print out Zones to be set in test mode 2 22 222 222 Start test 100 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Write zone numbers Zones to be set in test mode Press lt to start the test e g 001 002 003 001 002 003 004 mode 004 Zones in test mode LED Test mode L8 001 002 003 004 End test will light up Perform the tests The zone s will stay in test mode until the test mode is ended but after 60 minutes or if you press Esc menu you will be logged out from menu H1 Perform the test as quickly as possible since the output s for routing equipment fire brigade tx are disabled also the parts of the zones in test mode not visible for the test personnel are disabled In order to shorten the testing time any time delay for the detectors zones in test mode will be disabled i e fire alarm will be detected faster than normally In the tested alarm point the LED will light up and the LEDs Fire L1 in the c i e will light up approx 10 seconds then the alarm point will be automatically reset The printer if available will print out every tes
69. ay columns Use A and V to scroll between the main menus H1 H10 Use Enter to accept Some main menus have sub menus Use A and V to scroll between the sub menus e g B1 B9 Use to accept NOTE The menus are circular i e if you scroll with Y and the last menu is reached the first menu comes up next Quick jump can be used within each menu e g in menu H1 press 6 for a quick jump to menu H6 1 and then 0 within 1 sec 10 In some cases a cursor appearse g Disable zone Ho 0 It is then possible to type in digits with the numeric keys 0 9 Use lt gt A and VW to move the cursor in a menu Use ESC to go one step up in the menu system e g return from a sub menu to the main menu H1 H10 Use ESC or the soft key Esc menu to leave a main menu H1 H10 Use DEL to delete all visible entry fields Use the soft key Esc menu to leave the menu system It is always possible to leave any menu whenever the soft key Esc menu is available There will be an automatic log off 60 minutes after the last action i e if the key pad or a push button has not been used for 60 min and also when you close the door If you leave the menu system and if you don t close the door you don t need any access code to open the menu system again Some lists are dynamic lists i e the number of items per page depends on the size of each item Some lists are static lists i e a
70. ber of allowed loop units that can be used in this control unit i e 128 256 or 512 Convention Different countries have different conventions i e country specific functions default settings etc The convention is set in conjunction with the installation of Win512 version 2 7 x The convention can if required be changed via Win512 version 2 7 x Serial number The manufacturer s serial number year week number of the main board Name As written in the Win512 version 2 7 x dialog box System Properties Logical name Downloaded Date and time when the site specific data SSD was downloaded Control unit number 00 29 Menu According to chapter Access see page 98 Scroll to menu H4 H4 Present system status wal U1 Disablement U2 Disablement by time channel U3 Open doors U4 Sensor values U5 Sensors activating SERVICE signal U6 Event log U7 Information Scroll to menu U7 U7 Information To change the convention in Win512 version 2 7 x Level 2 has to be selected which require a special password 126 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Main board version vvvvvvvvvvvv If printer is mounted the MMI board version vvvvvvvvvvvv soft key Print will be Max number of allowed loop units xxx visible else not Press Convention cccccccccc Print for a print out Serial number xxxxxxx Name sssssssssss
71. ces in other control units or press ESC S5 Test alarm devices Scroll to another menu or press ESC 153 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 31 7 Safe shut down of control unit H8 S6 It s not recommended to power off a control unit i e no 230 V AC and no battery without first doing a safe shut down of control unit Safe shut down will save the SSW in a Flash ROM and put the CPUs at rest See also chapter Restart page 94 It s recommended to do a safe shut down after commissioning the installation and after the calibration of supervised outputs change of access code etc in order to save the new valid values codes etc Safe shut down can be performed from any control unit and any control unit can be selected A control unit without a front has to be shut down from another control unit NOTE By restart and power off the Fault tx output s will be activated Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page 129 S2 Re connect loop zone line input S3 Acknowledge SERVICE signal S4 Clear weekly average S5 Test of alarm devices S6 Safe shut down of control unit S7 Activate address in alarm mode S8 Synchronize the control units S9 Change code for service maintenance S10 Change code for PC communication Scroll to menu S6 S6 S6 Safe shut down of control unit ssi sh
72. ction is available only if it is set in Win512 version 2 1 x Press Reset P3 to reset the fire alarm currently shown in the middle of the display with large digits NOTE The push button has to be pressed for min 0 5 sec Output s programmed for that fire alarm alarm point zone will be reset i e de activated If more than one fire alarm is activated i e LEDs Alarms queued L6 are lit the next fire alarm in the queue will be shown in the middle of the display It has to be reset the same way as the first one 50 Panasonic Eco Solutions Nordic AB MEW01473 16 2 3 16 2 4 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x When all fire alarms are reset LEDs Fire L1 and Alarms queued L6 are turned off If there are other conditions e g a fault condition the corresponding information will be shown e g a fault message for the priority order see chapter The information area priority order page 23 All outputs for fire alarm are reset i e de activated If a key cabinet is installed the key to the building has to be put back into the key cabinet within 5 minutes If not a fault will be generated and a fault message will be shown in the display see chapter Key cabinet alarm reset page 52 Single with automatic disablement Like Single reset but incl the so called encapsulation function Normally when an alarm point or zone having activated fire a
73. cuit is detected when a COM loop is in service mode the loop will be disabled and a fault message will be displayed PAULP Slaoiwt Cilweult SCL A lt gt SCI B loop KX CoOmitieol UnNLE xx Independent of where the short circuit is situated on the loop Text in display Comments According to chapter Access code for service and maintenance H5 and H8 see page 129 A1 Calibration of supervised outputs Sensitive fault detection mode Service mode for COM loop Display current consumption in unit Display current consumption on COM loop Display statistics for communication Activate address setting mode for DU Service mode for BS4 loop Display current consumption on BS4 loop A3 Service mode for COM loop 132 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Service mode for COM loop ol CU 00 Write COM loop number B Direction and control unit number Both then select A direction B direction or Both Press lt 1 E g COM loop 3 Service mode for control unit 03 COM loop 3 Press lt ESC or Esc CU 03 and A Supplied from A direction only menu to terminate the direction service mode a Escape menu 2 or ESC A3 Service mode for COM loop Scroll to another menu or press ESC 133 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United
74. d paper roll e Place the new paper roll in the printer Make sure that it unrolls in the proper direction like the old one e Pull out 50 mm paper and close the cover e Tear off the paper then press the Paper feed button to the right on top of the printer front to check the paper feed function and tear off the paper e Acknowledge the printer fault e Close the control unit door 169 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 36 Replacing a TLON connection board and or the Main board By the TLON network programming some unique data will be stored in a memory on the 1590 5090 TLON connection board and some will be stored in a memory on the 5010 main board Replacing a TLON connection board 1590 5090 After replacing the board In TLON Manager version 1 2 do Replace Update and Save In TLON Manager version 2 0 do Replace and Update Save is aut done Replacing a TLON connection board 1590 5090 and also the Main board 5010 After replacing the boards In TLON Manager version 1 2 do Replace Update and Save In TLON Manager version 2 0 do Replace and Update Save is aut done Replacing the Main board 5010 After replacing the main board move the TLON connection board from the old main board to the new main board In TLON Manager version 1 2 do Update and Save In TLON Manager version 2 0 do Up
75. date Save is aut done 170 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 37 Battery maintenance The batteries 2 x 12 V 28 Ah e g Panasonic LC P1228AP are placed inside the control unit Larger batteries lt 65 Ah have to be placed outside the control unit e g in a separate battery cabinet etc The control unit supervise and charge the batteries and a fault will be generated for any trouble with the batteries The batteries rechargeable Sealed Lead Acid batteries shall fulfil UL94V 0 The batteries are normally maintenance free but the producer s instructions shall always be followed The ambient temperature affects the battery s capacity self discharge and life span The temperature should preferably not be higher than normal room temperature approx 20 22 C For highest safety the batteries used in a fire alarm installation should not be more than four years old CAUTION Risk of explosion if battery is replaced by incorrect type Dispose used batteries according to the producer s instructions and national regulations 171 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 38 How to avoid unnecessary nuisance fire alarms We all realise when life buildings production facilities etc shall be saved it is of utmost importance that an initi
76. ddresses don t have to be in sequence The connections on the COM loop don t have to be in sequence The address is for each unit set with the programming tool 3314 0 3 COM loop number 00 29 The control unit address number Don t have to be in sequence The connections to the TLON network don t have to be in sequence The address is set with a PC SW TLON Manager NOTE 37 Panasonic Eco Solutions Nordic AB MEW01473 14 2 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Presentation number For each fire alarm point input zone a presentation number NNN NN has to be programmed The presentation number is shown in the c i e display and ext FBP display to identify the point zone activating fire alarm It is also used to disable re enable fire alarm points zones and as trigger conditions in control expressions to activate programmable outputs Together with the presentation number a user definable 40 characters text message alarm text can be displayed if programmed NNN NN 00 99 01 99 The address within the zone 00 Only the zone number will be displayed e g used for conventional zone line inputs 001 999 Zone number NOTE Zone numbers 001 999 can be used but not more than 512 alarm points and or zones can be used per c i e This is in accordance with the EN54 2 standard 17 Also in the Alert Annuncia
77. dic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x This is indicating a break cut off or a missing end of line resistor on input x zone line on the 1580 board placed in control unit xx It can also be a detector that have been removed stolen from its base NOTE The input can as an alternative be used for a single slave unit control unit or several control units connected in parallel i e it is used for Redundancy in distributed system In such a case the output for routing equipment fire brigade tx in the slave unit respectively works as a detector 1584 Autronica interface board BS4 Cut off break on the BS4 loop This is indicating a single break on the loop Communication has to be performed in both directions to find all units Each 10 minute is an attempt made to comm in one direction again This is indicating a single break on the COM loop x when one or more short circuit isolators are connected on the loop Communication has to be performed in both directions to find all units The break is to be found in the specified segment e g ASF 3 lt gt CU between short circuit isolator no 3 and the control unit Each 10 minute is an attempt to comm in one direction made again 62 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x PAULUS Curc Oiric loos K COmeroOl wait
78. e disabled or the outputs in all control units Disabled alarm devices are indicated by LEDs Fault Disablements Alarm devices L11 and General disablements L10 and shown in menu H4 U1 from which it is possible to get a print out When all outputs have been re enabled The LEDs Fault Disablements Alarm devices L11 and General disablements L10 will be turned OFF if there are no other disablements in the system The outputs will be disabled until re enabled again via this menu Menu According to chapter Access see page 98 Scroll to menu H2 H2 Disable or re enable Disable zone Disable zone address Disable output Re enable zone Re enable zone address Re enable output Disable re enable output type Disable re enable alarm devices Disable re enable routing equipment B10 De activate alert annunciation function B8 Disable re enable alarm devices Select control unit fo All Write the CU number or Press gt and select All Blank space all CUs Press Disable or Re enable Escape menu 114 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Disable or Re Select control unit fo All Press ESC Scroll to enable another menu or press Blank space ESC Escape menu DIREI BERAE 115 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm
79. e even longer e g the Multipurpose I O unit 3361 has an internal delay time of 30 seconds which results in 45 30 75 seconds delay time in total 8 The buzzer in the control unit can be suppressed for faults generated in other control units Suppressed buzzer during fault is set via Win512 version 2 7 x 54 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x e Inthe c i e display can up to three fault messages be shown simultaneously In the display down to the left is displayed the number of not acknowledged faults e Ifa fault has been corrected serviced before it has been acknowledged the status information is serviced see above e Fire alarm presentation has higher priority than the fault messages however during fire alarm presentation the faults can be shown via the menu system see page 43 Faults normally latched have to be acknowledged which is done via menu H6 see page 142 This menu is a list of all faults in the system not corrected serviced and not acknowledged fault not corrected serviced but acknowledged fault acknowledged corrected serviced but not acknowledged fault serviced If a fault cannot be corrected it is important to contact service personnel engineer immediately NOTE As a reminder faults and disablements are indicated by a 2 sec beep when an open c i e door is being closed 2 Can via W
80. e following chapters are all different alarm types described The figures in this document show the essential information and might not look exactly as shown in the display Pre warning Activation of Pre warning is an option that has to be enabled via Win512 for the control unit respectively Note Pre warnings activated in any control unit in the system will always be presented in all control units and all programmable outputs in the system with trigger condition pre warning will be activated if not disabled An analog detector will generate a pre warning for a lower alarm level than the fire alarm level Pre warning can be used when an early warning and or an early action is required e g a soft computer shut down Normal alarm devices output type Alarm devices routing equipment etc will not be activated In case of a pre warning the following happens S See EBL512 G3 Planning Instructions Any programmable input can also be used to activate a pre warning e g for a High Sensitivity Smoke Detector system 39 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x e The buzzer in the c i e sounds 0 8 sec each 5 sec 0 8 5 sec e Outputs programmed for pre warning are activated e Inthe c i e display a presentation number zone address is shown for the first pre warning e Inthe c i e display a user defin
81. e test solely In test mode only the alarm points are tested i e no outputs no sounders will be activated during the test Alarm devices can be tested via menu H8 S5 If a real fire alarm is activated by an alarm point not in test mode the normal fire alarm functions will be activated i e fire alarm presentation outputs sounders activated routing equipment fire brigade tx activated etc See also chapter The information area priority order page 23 NOTE If the control unit door is left open the output s for routing equipment fire brigade tx might be disabled if set so in Win512 version 2 7 x There will be an automatic test mode ending one hour after the latest tested alarm point Text in display Comments Menu According to chapter Access see page 98 Scroll to menu H7 H7 Perform ZONE TEST lt 1 Zones to be set in test mode H2 222 222 272 Zones to be set in test mode Press lt to start the test 001 002 003 Moo mode Write the zone numbers e g 001 002 003 004 a Zones in test mode LED Test mode L8 001 002 003 004 End test will light up Perform the tests The zone s will stay in test mode until the test mode is ended but after 60 minutes or if you press Esc menu you will be logged out from menu H7 Perform the test as quickly as possible since the output s for routing equipment fire brigade tx are disabled also the parts of the zones in test mode n
82. ed version 2 7 x ne ese Fire Alarm Zone 002 Address 03 SMOKE YYYY MM DD hh mm User definable alarm text if progr Reset of the fire alarms see chapter Alarm reset page 50 15 2 1 Enter the menu during fire alarm By pressing the soft key Menu P4 during fire alarm you will get access to the menu system see Access page 98 NOTE Access code is required In this case a part of the display s alarm window will be temporarily suppressed to permit the display of the menu system First alarm 002 03 4 zones in alarm Latest alarm 003 11 menu H2 Disable or re enable H3 Set calendar and clock H4 Present system H5 Service H6 FAULT acknowledge H7 Perform zone test Test mode H8 Maintenance H9 Interlocking outputs and inputs H10 Change access code for daily duties Esc menu The normal alarm window will be automatically displayed again after the menu system is escaped or 5 minutes after the latest manoeuvre in the menu system The alarm window will also be automatically displayed again if any of the soft keys Esc menu P4 or ESC is pressed or push button Alarms queued P8 15 2 2 Acknowledged and Isolated alarm Acknowledged and Isolated alarm is a fire alarm function only used in New Zealand Acknowledged alarm 43 Panasonic Eco Solutions Nordic AB MEW01473 15 3 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x A fire alarm presented
83. ensor Zone XXX address AA needs service sensor has a border technical address xxxxxx Press lt to acknowledge 2010 02 03 19 09 35 the sensor Number of sensors xx 149 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x The service signal for the selected sensor is now Continue like above or acknowledged and the next sensor will be shown press ESC to menu S3 Sensor Zone XXX address AA needs service technical address xxxxxx 2010 02 03 19 09 35 Sensor Zone YYY address AA needs service technical address xxxxxx 2011 01 03 09 19 55 Number of sensors xx S3 Acknowledge SERVICE signal Scroll to another menu or press ESC The Service symbol 4 and the Service message will be turned off when all sensors have been acknowledged 150 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 31 5 Clear weekly average H8 S4 If a sensor analog smoke detector is replaced without having generated SERVICE signal its week average sensor value has to be cleared and set to the default value otherwise the new clean sensor will inherit the old sensor s value It is possible to clear the week average sensor value for each sensor individually via this menu NOTE First replace the sensor and then clear the week average value as soon as possible Authorised service
84. er Access see page 98 Scroll to menu H6 H6 H6 Acknowledge FAULTS 2 FAULTS PF Some examples of fault messages This is a list in which you can scroll The most recent fault is on top of the list A corrected fault is indicated by serviced FAULT Low battery capacity control unit 00 yyyy mm dd hh mm FAULT No reply zone 045 address 06 An acknowledged fault is technical number 000005 yyyy mm dd hh mm serviced FAULT No reply zone 021 address 05 technical number 000114 yyyy mm dd hh mm acknowledged Fault 1 3 is selected FAULT Low battery capacity control unit 00 yyyy mm dd hh mm acknowledged FAULT No reply zone 021 address 05 technical number 000114 yyyy mm dd hh mm acknowledged Fault 1 2 is selected indicated by acknow ledged To acknowledge a fault select it and press lt The selected fault has a boarder around it A corrected serviced fault that you acknow ledge will disappear from this list ESC H6 Acknowledge FAULTS Scroll to another menu or press ESC When the list is empty i e when all faults are acknowledged and corrected you will automatically return to menu H6 142 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 30 Perform ZONE TEST Test mode H7 Normally zones are tested during the monthly test via menu H1 Via this menu H7 it is possible to perform the zon
85. fixed maximum number of items per page NOTE In the following chapters are all the menus described The Text in display column shows the essential text and might not look exactly as shown in the display 99 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 24 Perform monthly test H1 The control unit and the installation shall be tested on a regular basis If one twelfth of the alarm points are tested each month the whole installation will be tested after one year In test mode only the alarm points are tested i e no outputs no sounders will be activated during the test Alarm devices can be tested via menu H8 S5 If a real fire alarm is activated for example by an alarm point not in test mode the normal fire alarm functions will be activated i e fire alarm presentation outputs sounders activated routing equipment fire brigade tx activated etc See also chapter The information area priority order page 23 NOTE If the control unit door is left open the output s for routing equipment fire brigade tx might be disabled if set so in Win512 version 2 7 x There will be an automatic ending of the test mode one hour after the latest tested alarm point zone See also chapter Perform ZONE TEST Test mode H7 page 143 Menu According to chapter Access see page 98 PF H1 Perform monthly test Check th
86. for approx 5 seconds and so 64 on NOTE Also disabled and silenced alarm devices will be tested The test will continue for one hour if not stopped via this menu H8 S5 or if a fire alarm is activated in the system Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page 129 S2 Re connect loop zone line input S3 Acknowledge SERVICE signal S4 Clear weekly average S5 Test of alarm devices S6 Safe shut down of control unit S7 Activate address in alarm mode S8 Synchronize the control units S9 Change code for service maintenance 10 Change code for PC communication Scroll to menu S5 S5 S5 Test alarm devices 2 alarm devices Pe ed Test alarm devices control unit do All Write control unit number or press gt for All Press lt to start the test Including Addressable siren 3377 and Addressable sounder base 3379 6t For the alarm devices 3377 and 3379 the tone with the highest priority level and type alarm device will be automatically selected 152 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Test of alarm devices in progress The test will continue for End test one hour if not stopped via this menu S5 or if a fire alarm is activated in the system Press lt to stop the test Test alarm devices control unit do All Continue like above to test alarm devi
87. g and connections on the board Check programming Win512 version 2 7 x PAURES 1569 Excel Slicing System Comczrol W gt e Fault in the extinguishing system equipment connected to the 1583 56 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x German Fire Brigade Panel interface board in control unit No xx FAULT 1583 GFBP interface board Control WNIT SS German Fire Brigade Panel interface board Fault on no communication to 1583 board in control unit No xx Check address setting and connections on the board Check programming Win512 version 2 7 x Check the fuses F1 and F2 on the 1583 board RAUDE ISG4 Murcwomiea loose x CU sox Autronica interface board Fault on no communication to 1584 board No x in control unit No xx Check address setting and connections on the board Check programming Win512 version 2 7 x FAULT 1587 board x CU xx External Fire Brigade Panel DU interface board Fault on no communication to 1587 board No x in control unit No xx Check address setting and connections on the board Check programming Win512 version 2 7 x IVAWILIES 24 Wi Or eee eoU pment CONnt eol WILE eae Check the fuses F2 and F4 on the connection board 1555 Supervised output S2 is also supplied via F2 and F4 PAULI 24V tor external ecuipment OUTO xX comaa Wine sox x Power supply output 1 4 J3 5 12
88. h Safe shut down the latest SSW data is saved When EBL512 G3 is powered up the RAM working memory will after the restart read the SSW data saved in the Flash ROM The date amp time and alarm counter values are stored in the memory of the real time clock i e the value will be retained also after the c i e has been de energized NOTE After any restart a new week average sensor value will be calculated within two minutes for all the analog smoke detectors During these two minutes all fire alarms from analog smoke detectors will be suppressed Thereafter a new average sensor value will be calculated each week Here follows a table describing the different reset alternatives and how the data respectively is affected 94 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Action Data etc Data etc Restart which will be which will be code deleted not deleted Power down de energize and SSW SSD then power up again Cold restart FFD WASV S W Via menu H8 S6 Safe shut down of FFD WASV SSD 00 alt 03 control unit Cold restart S W SSW Main board RESET button FFD WASV SSD 03 s w SSW MMI board RESET button SSD no fault s w SSW FFD WASV Reset command via Win512 version FFD WASV SSD 2 7 x or TLON Manager S W SSW Automatically after download of site FFD WASV SSD 03 specific data SSD via a PC amp S W
89. h the queued zones use the soft key Next zone P5 NOTE Fire alarms are Fire alarm Heavy smoke heat alarm Alert Annunciation AA alarm Key cabinet alarm Acknowledged alarm New Zealand only Isolated alarm New Zealand only Encapsulated reset aut disablement Press Reset P3 and approx 0 1 sec later also Alarms queued P8 See also page 51 gt Outputs of type Alarm devices will be de activated t The soft key P7 has the function Evacuate in the following conventions Belgian British Standard Hungarian Spanish and Ukrainian In all other conventions it has the function Alert Annunciation Acknowledge 19 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x LED indicators on the Control Panel CP LED indicator Indicating System fault yellow EBLS512 G3 is not running because of S W CPU or memory fault no contact between main board and MMI board or c i e restart fault code 00 03 Test mode yellow Zones are in test mode see page 100 and 143 Fault Disablements General fault yellow Fault s in the system i e not acknowledged fault s and or not corrected fault s See also page 142 L10 General disablements Disablement s in the system Also valid for Single yellow with automatic disablement see page 51 p Alarm devices yellow Steady cont Output s type Alarm device are disabled
90. he SSW will get default values and the fault will be corrected serviced Supervised outputs have to be calibrated via menu H5 A1 e Some external influence has caused a fault in the SSW This is very serious Call for service personnel engineer Control unit restart has occurred in control unit no nn See also page 94 xx 00 Power up Restart Power supply connected xx 01 Watchdog Reset xx 02 Accidental jump to reset vector xx 03 Restart after SSD Software download xx 04 19 Unexpected interrupt xx 20 S W monitoring fault NOTE xx 00 and 03 are normal Acknowledge the fault xx 01 02 or 04 20 appearing often call for service personnel engineer yy y memory address before restart Write down the address and inform the service personnel engineer FAULT Sensor technical number xxxxxx The analog smoke heat or multi detector is not all right i e the detector is faulty The detector s built in self verification function has reported a fault The detector has to be replaced 73 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x FAULT Sensor zone xxx address technical number xXxxxxx The analog smoke heat or multi detector is not all right i e the detector is faulty The detector s built in self verification function has reported a fault The detector has to be replaced BAU SNoOrt eii reunit CON Noo Conte
91. ication on a BS4 loop in one direction FAULT No reply techn no xxxxxx will be generated with a reduced delay time This function can be used to list all technical numbers behind a loop cut off NOTE Loop cut off and short circuit faults cannot be generated since they require communication in both directions at the same time When you leave this menu or if you are automatically logged out after 60 min the Service mode for BS4 loop will be terminated automatically and the communication will start in the A direction NOTE If short circuit is detected when a BS4 loop is in service mode the loop will be disabled and a fault message will be displayed BAULT Slao iet O sLie walt LOO x CoOmcrol wmi Independent of where the short circuit is situated on the loop Text in display Comments A1 Calibration of supervised outputs Sensitive fault detection mode Service mode for COM loop Display current consumption in unit H8 see page 129 Display current consumption on COM loop Display statistics for communication Activate address setting mode for DU Service mode for BS4 loop Display current consumption on BS4 loop Scroll to menu A8 A8 Service mode for BS4 loop An Autronica interface board 1584 is required in the control unit 139 According to chapter Access code for service and maintenance H5 and Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm
92. ifferent zones First alarm 002 03 Alarm number 1 of 10 Zone Address 02 03 SMOKE User definable alarm text for 002 03 Latest alarm 003 11 4 zones in alarm Next zone SMOKE after the presentation number is automatically added depending on the type of alarm point i e SMOKE HEAT MULTI or MCP User definable alarm text For each alarm point can an individual alarm text be shown if programmed or the default control unit alarm text if programmed For each zone it is an individual alarm text if programmed Up to 40 alphanumeric characters can be used Additional information First alarm Latest alarm Alarm number and number of zones in alarm LEDs Alarms queued L6 blinking 0 4 0 4 sec are indicating that more than one fire alarm is activated To scroll through the alarm points use the push button Alarms queued P8 Next zone Use the soft key Next zone P5 to scroll through the zones in alarm When scrolling through the zones the first alarm point activated in the next zone will be shown The Next zone button will be available only if there are alarms in more than one zone The first alarm will be automatically displayed again 20 seconds after the latest time the Alarms queued or Next zone buttons where used The printer if available will print each fire alarm e g 42 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 Unit
93. in the display can be acknowledged by pressing the soft key Acknowledge P7 Acknowledged alarms are indicated in the display by Acknowledged alarm in the same position as Heavy smoke Heavy heat see below This indication is the only difference between a normal fire alarm and an acknowledged alarm Acknowledged alarms have to be reset like normal fire alarms Isolated alarm A normal fire alarm or an acknowledged alarm presented in the display can be isolated as follows When the New Zealand FB Silence switch outside switch is turned OFF from activated to not activated any fire alarm and acknowledged alarm will be isolated disabled Isolated alarms are indicated in the display by Isolated alarm in the same position as Heavy smoke Heavy heat see below Isolated alarms do not activate any control outputs do not activate the output for routing equipment Fire brigade tx do not activate the c i e buzzer and do not activate the LEDs Fire L1 in the c i e Isolated alarms have to be reset like normal fire alarms Isolated alarms also have to be re enabled via menu H2 B5 or B4 before they can activate a new fire alarm again Heavy smoke alarm Heavy heat alarm An analog detector can activate a heavy smoke heat alarm for a higher alarm level than the normal fire alarm level i e a normal fire alarm is already activated by a detector activating a heavy smoke heat alarm Hea
94. in512 version 2 7 x be set to be not latched 55 Panasonic Eco Solutions Nordic AB MEW01473 17 1 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Fault messages Below follows a list of all fault messages in alphabetical order There is also an explanation to each fault Some of the fault messages are valid for EBL512 control units only some of the fault messages are valid for EBL512 G3 control units only and some of the fault messages are valid for Checksum fault in downloaded data Comcrcol wait will mow rcestaicec A fault in the downloaded Site Specific Data SSD After the restart a new fault will be generated FAULT Site Specific Data SSD control unit xx A new SSD download will probably solve the problem FAULT 1580 8 womes board x Control unir XX 8 zones expansion board DET8 Fault on no communication to 1580 board No x in control unit No xx Check address setting and connections on the board Check programming Win512 version 2 7 x AUILIES M561 Relay boae x Control tnit sox 8 relays expansion board Fault on no communication to 1581 board No x in control unit No xx Check address setting and connections on the board Check programming Win512 version 2 7 x BAUME 15821 PBE inter tace Doarcd x CU xx External Fire Brigade Panel interface board Fault on no communication to 1582 board No x in control unit No xx Check address settin
95. ing replacement of the sensors detectors Metal objects must absolutely not be stuck into the sensor detector Static electricity might destroy the detector Defective faulty discarded and replaced sensors detectors shall be taken care of as radioactive waste They shall be packed in chock absorbing material to make a stable parcel PLEASE NOTE Damaged sensors detectors shall also be packed in a sealed packet whose surface must not be contaminated that is not be soiled with loose radioactive dust National regulations have to be followed 174 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 40 Revision history 175 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 176 This page has deliberately been left blank Panasonic Panasonic Eco Solutions Nordic AB Jungmansgatan 12 SE 211 19 Malmo Sweden Tel 46 0 40 697 70 00 Fax 46 0 40 697 70 99 info pewnf eu panasonic com www panasonic fire security com ISO 9001 NATIONAL AOCREDITATION OFCERTIFCATION BODES
96. ing sprays etc If many odd and unnecessary alarms occur the environment must be examined and perhaps other detector types have to be chosen Steam hot air Smoke and heat detectors are influenced by steam and hot air e g from an oven dry blower heater etc 172 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Exhausts Exhausts from cars trucks lift trucks lawn mowers etc influences smoke detectors sensors If windows and doors are open exhausts can slip in that way Lack of maintenance Smoke detectors sensors are influenced by their environment and become dirty In an analog system like EBL512 G3 a Service signal is given when it is time to exchange the smoke detectors sensors to new ones The alternative is to exchange detectors at given periods to be on the safe side Change in activities or wrong choice of detector If the activities in the premises are altered the detector choice might also need to be altered Due to special environments see above an in appropriate detector type might have been chosen from the beginning and thus cause unnecessary alarms Miscellaneous Choosing another type of detector can solve certain problems Bear also in mind that the coverage area can be different for different types of detectors It is however not always the best action to change detector type Here is a list of othe
97. int out Sensor 001 03 technical address 000002 Momentary XX C Min XX C Algorithm XX Max XX C Escape menu a Start sensor ooo00 Write another technical number and press 4 or press ESC ESC U4 Sensor values Scroll to another menu or press ESC 122 Panasonic Eco Solutions Nordic AB MEW01473 Rev Xm Momentary sensor values for 24 hours Xwa weak average sensor value 14400 pollings during 24 hours Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Regarding the Performance factor The Performance factor can be 0 00 2 55 How the Performance factor Pf is calculated is shown to the left The Performance factor is normally close to 0 00 which means that the detector is mounted in a stable environment The momentary sensor values during 24 hours do not differ a lot from the week average sensor value In an unstable environment the Performance factor will be higher than 0 00 This could for example be the case in a factory e g dirty activities during working hours no or clean activities during the night and is not a problem as long as there are no nuisance false alarms or other problems Algorithms Table showing the algorithms and the shortenings respectively Algorithm Short name Normal sensitivity 3 m amp Normal detection 15 s N 15 High sensitivity 2 4 m amp Normal detection 1
98. ion 2 7 x The two wires L SA and C SB for COM loop no x 0 3 in control unit no xx have been mixed alternated Check correct the wire connections The communication with the unit not a detector is not all right i e the unit is out of order faulty and has to be replaced The unit detector is not all right i e the unit is out of order faulty and has to be replaced 512 Battery internal resistance is too high The battery might be too old Cables fuses etc for externally placed batteries might cause a voltage drop Check adjust the rectifier power supply voltage 24 V DC Check the charging voltage over the battery respectively 13 5 13 8 depending on the actual charging step Check the voltage over a disconnected battery fully charged gt 13 V NOTE The battery check is performed every 12 hour i e it can take up to 12 hours until the fault status will be corrected In the New Zealand convention only The battery charging is turned off 60 minutes every 24 hour A battery voltage lt 24 4 V during these 60 minutes will generate a fault If a fault is generated it will automatically be Serviced after these 60 minutes 512 G3 Battery in control unit no xx internal resistance gt 0 6 Q e The battery might be too old Cables fuses etc for externally placed batteries might cause a voltage drop Check adjust the rectifier power supply voltage 24 V DC 68 Panasonic Eco Sol
99. ist showing a maximum of 300 faults not acknow ledged faults and or acknowledged but not serviced corrected faults e All faults have to be individually acknowledged one by one by the key pad button Ww Use or w to scroll e Ifa fault has been corrected before it has been acknowledged the text Serviced is added after the time It still has to be acknowledged 3 Indicating that output for routing equipment Fault tx is activated 81 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x e When a fault is corrected serviced and acknowledged it will disappear from the list H6 e When all faults have been acknowledged output s for routing equipment Fault tx is are reset i e the LED Routing equipment Fault tx activated L13 will be turned off 32 e As long as there are faults i e not acknowledged faults and or acknowledged but not corrected faults the LED Fault Disablements General fault L9 will be lit and general fault and maybe general charge fault output s are activated e Faults corrected faults and acknowledged faults are shown in the General event log menu H4 U6 32 In the Australian and New Zealand conventions the LED L13 is turned on and the output s for routing equipment Fault tx is are activated until there are no faults in the system 82 Panasonic Eco Solutions Nordic AB MEW01473 1
100. its Documents The following documents are available e Planning instructions MEW01472 e Operating instructions this document e Drawings Normally information found in one of the documents is not found in another document i e the documents complement each other Applications The EBL512 G3 system is intended for small medium and large installations The intelligent control units offer the system designer and end user a technically sophisticated range of facilities and functions Programming PC software Win512 version 2 7 x and TLON Manager and commissioning of the control unit system is very easy Start with one control unit and then later when it is required add more units The TLON network makes it possible to install the control units in one building or in many buildings PC S W Win512 EBL512 G3 software United version 2 7 x is only used in a mixed system see chapter Mixed system page 12 For this reason Win512 version 2 7 x is used for programming and commissioning of one or more control units i e to e create download backup upload site specific data SSD e conventions configurations control unit amp system properties etc 14 Panasonic Eco Solutions Nordic AB MEW01473 3 5 2 3 5 3 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x e create download the user definable text messages alarm texts shown in the display in the C U and ext FBP Dis
101. ivated to activated state FAULT Fire brigade panel xx Control unit xx 65 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x FBP 1826 1828 Ext Fire Brigade Panel The ext FBP xx connected to control unit no xx is programmed as another type in the SSD or a fault in the unit FAULT Fire brigade panel xx expansion Conco vnit Sex FBP 1826 1828 Ext Fire Brigade Panel The ext FBP xx connected to expansion board x in control unit no xx is programmed as another type in the SSD or a fault in the unit FAULT Fuse 1580 8 zones board x control TLE Ses DET8 1580 8 zones expansion board Check for blown fuse on the 1580 board FAULI Huse 15392 EBE board x U xx External Fire Brigade Panel interface board 1582 Check for blown fuses on the 1582 board FAULT Fuse 1584 Autron board x CU xx BS4 1584 Autronica interface board Blown fuse on the 1584 board The fuse is not replaceable The board has to be replaced FAUNE Puse 1587 poard x CU xx External Fire Brigade Panel DU interface board 1587 Check for blown fuses on the 1587 board 512 The fuse is not replaceable More components might also be broken The main board 1556 has to be replaced 512 G3 Blown fuse F15 Loop 0 F16 Loop 1 F17 Loop 2 or F14 Loop 3 on the main board 5010 in control unit no xx Fuse T1 6A L 250V TR5 NOTE The fuse shall not
102. l Zone Address unit displays and all ext FBP displays and indicated 1 2 3 4 5 by the LEDs Fire L1 SMOKE and Fire brigade tx L4 This manually activated fire alarm has to be reset by the push button Reset P 1 zone in alarm Ea 157 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 31 9 Synchronize the control units H8 S8 After any control unit restart synchronization will start automatically Synchronization can also be started via Win512 version 2 7 x and via this menu H8 S8 The control units have to be synchronized when the following fault message is Shown FAULT Control unit xx has wrong information During the synchronization there will be information displayed for all control units in the system U rotating clockwise Synchronization in progress for the control unit CU respectively v Synchronization completed successfully for the control unit CU respectively lt Blank gt Synchronization failed for the control unit CU respectively Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page 129 S2 Re connect loop zone line input S3 Acknowledge SERVICE signal S4 Clear weekly average S5 Test of alarm devices S6 Safe shut down of control unit S7 Activate address in alarm mode S8 Synchronize the control units S9 Change code for service maintenance S1
103. l unit system 10 Panasonic Eco Solutions Nordic AB MEW01473 2 11 2 12 2 13 2 14 2 15 2 16 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x System Several control units connected via a TLON network co operating control units Network TLON LonWorks Echelon Node TLON Conn board Gateway Sub net Backbone net Router Repeater Brief explanations to the words expressions to be found in connection with a network See also separate TLON Technical description TLON TeleLarm Local Operating Network a LonWorks based network for communication between several units nodes The protocol is LonTalk and the transmission works with doubly terminated bus topology Echelon FTT 10 To connect a control unit to the network a TLON connection board has to be plugged in the control unit EBL512 G3 also supports redundant TLON system communication In this case two TLON connection boards have to be plugged in each control unit A network can be one channel FTT 10 or several channels connected via routers In the TLON Network a sub net a channel Routers are also used to increase the maximum cable length node to node in a network Router or Repeater is the same type of unit different configuration All network programming configuration are made with the PC program TLON Manager LED LED Light Emitting Diode Yellow green or
104. larm is reset when it still is in alarm status it will activate a new fire alarm within 20 seconds In accordance with the EN54 2 standard When Single with automatic disablement reset is performed an alarm point or zone still in alarm status will not only be reset but also disabled i e it will not activate a new fire alarm within 20 seconds It has to be re enabled via menu H2 B5 before it can activate a new fire alarm This function set via Win512 version 2 7 x is a violation to the EN54 2 standard LED Fault Disablements General disablements L10 is indicating one or more disablements in the system NOTE When All or Single reset is used automatic disablement encapsulation function can be used by pressing Reset P3 and approx 0 1 sec later also press Alarms queued P8 and hold them pressed for gt 0 5 sec The alarm point or the whole zone conventional currently shown in the middle of display with large digits will be reset and disabled Acknowledged and Isolated alarm Acknowledged alarm and Isolated alarm are fire alarm functions only used in New Zealand Acknowledged alarm Acknowledged alarms have to be reset like normal fire alarms Isolated alarm Isolated alarms have to be reset like normal fire alarms Isolated alarms also have to be re enabled via menu H2 B4 or B5 before they can activate a new fire alarm again 51 Panasonic Eco Solutions Nordic AB MEW01473 16
105. larm points combination 44 Tn a mixed system the maximum number of alarm points 128 256 or 512 is equal to the maximum number of addresses 92 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 21 1 Control Units ina TLON network All control units connected to a TLON network do not have to have the same max number of alarm points addresses set 93 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 22 Restart A restart will delete or not delete the data in EBL512 G3 Below follows an explanation of the different data abbreviations and a table showing how the data respectively is affected cold or warm restart FF Fire alarms and Faults D Disablements FFD Fire alarms Faults and Disablements SSW Sensor min max values amp performance factor access codes supervised output calibration values and event logs WASYV Week Average Sensor Values SSD Site Specific Data i e all the installation programming created and downloaded via Win512 version 2 7 x S W Software i e the system program EBL512 G3 United version 2 7 x Safe shut down of control unit menu H8 S6 will save the SSW data i e not the week average sensor values in a Flash ROM before you power off de energize EBL512 G3 Before the first Safe shut down this memory is empty After eac
106. le or re enable H2 103 25 1 Disable zone H2 B1 104 25 2 Disable zone address H2 B2 105 25 3 Disable output H2 B3 107 25 4 Re enable zone H2 B4 108 25 5 Re enable zone address H2 B5 109 25 6 Re enable output H2 B6 110 25 7 Disable re enable output type H2 B7 112 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 25 8 Disable re enable alarm devices H2 B8 114 25 9 Disable re enable routing equipment H2 B9 116 25 10 De activate Alert Annunciation function H2 B10 ____ 117 26 Set calendar and clock H3 118 27 Present system status H4 119 27 1 Disablement H4 U1 119 27 2 Disablement by time channel H4 U2 120 27 3 Open doors H4 U3 121 27 4 Sensor values H4 U4 122 27 5 Sensors activating SERVICE signal H4 U5 124 27 6 Event log H4 U6 125 27 7 Show information H4 U7 126 28 Service H5 128 28 1 Access code for service and maintenance H5 and H8 __ 129 28 2 Calibration of supervised outputs H5 A1 130 28 3 Sensitive fault detection mode H5 A2 131 28 4 Service mode for COM loop H5 A3 132 28 5 Display current consumption in unit H5 A4 134 28 6 Display current consumption on COM loop H5 A5 ____ 135 28 7 Display statistics for communication H5 A6 136 28 8 Activate address setting mode for DU H5 A7 138 28 9 Service mode for BS4 loop H5 A8 139 28 10 Display current consumption on BS4 loop H5 A9 ___ 141 29 FAULT Acknow
107. led by time channel in CU XX yyyy mm dd hh mm Disablement 1 to 3 of 7 Escape menu Press lt to show all disablements in the system U1 A dynamic list in which you can scroll with W or n A Pi If printer is mounted the soft key Print will be visible else not Press Print for a print out of all items in the list If there are no disablements when lt is pressed the list view will not open ESC U1 Disablement Scroll to another menu or press ESC 119 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 27 2 Disablement by time channel H4 U2 A Static list 4 items per page of all disablements by time channel s in the system NOTE All other disablements are listed in menu H4 U1 Menu According to chapter Access see page 98 Scroll to menu H4 H4 Present system status wa U1 Disablement U2 Disablement by time channel U3 Open doors U4 Sensor values U5 Sensors activating SERVICE signal U6 Event log U7 Information Scroll to menu U2 U2 Disablement by time channel wj When lt is pressed the disablements will be shown in the A static list 4 items per display Some examples page in which you can Zone XXX address XX disabled by time channel scroll with Y or A Zone XXX address YY disabled by time channel if theredre no ok disablements when lt is ne pressed the list view will
108. ledge H6 142 30 Perform ZONE TEST Test mode H7 143 31 Maintenance H8 145 31 1 Access code for service maintenance 145 31 2 Disconnect loop H8 S1 145 31 3 Re connect loop H8 S2 147 31 4 Acknowledge SERVICE signal H8 S3 149 31 5 Clear weekly average H8 S4 151 31 6 Test of alarm devices H8 S5 152 31 7 Safe shut down of control unit H8 S6 154 31 8 Activate address in alarm mode H8 S7 156 31 9 Synchronize the control units H8 S8 158 31 10 Change code for service maintenance H8 S9 160 31 11 Change code for PC communication H8 S10 161 32 Interlocking outputs and inputs H9 162 32 1 Activated interlocking outputs inputs H9 C1 162 32 2 Activate interlocking output H9 C2 163 32 3 Reset interlocking output H9 C3 164 32 4 Disable interlocking output H9 C4 165 32 5 Re enable interlocking output H9 C5 166 33 Change access code for daily duties H10 167 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 34 Annual control 168 35 How to change paper in the printer 169 36 Replacing a TLON connection board and or the Main board 170 37 Battery maintenance 171 38 How to avoid unnecessary nuisance fire alarms 172 39 Information regarding radioactive radiation source174 40 Revision history 175 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Panasonic Eco Solutions
109. loop Display statistics for communication Activate address setting mode for DU Service mode for BS4 loop Display current consumption on BS4 loop Scroll to menu A9 A9 Display current consumption on BS4 loop lt Display current consumption on BS4 loop a Write BS4 loop number board 0 control unit 00 press lt board number and EBL512 control unit number and press lt E g BS4 loop 3 board 0 CU 03 and lt If the control unit don t exist or don t answer Current consumption on BS4 loop 3 board 0 The current consumption control unit 03 is xxxx mA accuracy is 5 mA 2 or ESC A9 Display current consumption on BS4 loop Scroll to another menu or press ESC 6l An Autronica interface board 1584 is required in the control unit 141 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 29 FAULT Acknowledge H6 Regarding fault indication etc see chapter Fault page 54 See also chapter Fault acknowledge page 81 All faults and the status action are stored in the event log and can be listed see chapter Event log H4 U6 page 125 In menu H6 can be listed up to 300 faults Not corrected not serviced and not acknowledged faults no status Not corrected not serviced but acknowledged faults acknowledged Corrected serviced but not acknowledged faults serviced Menu According to chapt
110. lts 2 sec directly after the door to the c i e is closed Activated interlocking input 0 8 0 8 sec if this option is selected via Win512 version 2 7 x Press Silence buzzer P1 to silence the buzzer In case of a new alarm pre warning co incidence alarm etc or if the push button Silence buzzer is pressed again the buzzer will automatically sound again Silence buzzer by open door In Win512 can the function Silence Buzzer by Door Switch be selected The buzzer will then be turned off as long as the control unit door is open This function is a violation to the EN54 2 standard EBL512 G3 c i e type no 5001 This unit has no front and no built in buzzer 13 Incl Heavy smoke heat alarm AA alarm Key cabinet alarm and Acknowledged alarm New Zealand only 33 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 11 Disable Re enable all control extinguishing and ventilation outputs All control outputs programmed as type e Control general e Extinguishing e Fire ventilation e Control Extinguishing Fire ventilation can via menu H2 B7 be collective disabled for one several or all control units This is indicated by LED Fault Disablements General disablements L10 They will remain disabled until they are re enabled again via menu H2 B7 See also chapter Disable re enable output type H2 B7
111. m information or via a Web server On site new S W can be downloaded via WinG3 version 1 1 x EBL512 G3 type 5000 has both a Main board 5010 and an MMI board 5011 EBL512 G3 type 5001 has only a Main board 5010 On site new S W for the 1728 1735 1736 1826 amp 1828 units can be downloaded via Win512 version 2 7 x See the Technical Description for the unit respectively Single control unit c i e To download a new software system program version in an EBL512 G3 control unit a PC and WinG3 version 1 1 x has to be used The BIN file that shall be downloaded contains software for the main board 5010 software for the MMI board 5011 and a text file 1 e there is one BIN file for each language country 1 Connect the PC to the USB connector in the c i e and start WinG3 version 1 1 x In the Tools menu select Download Software to open the dialog box and do the required settings Select the path and the software file name e g English_EBL512G3_United270 BIN United270 United version 2 7 0 Mark the checkbox No MMI board if it is an EBL512 G3 type 5001 i e the MMI software and the text file will not be downloaded Select the COM port to be used on your PC 41 Software cannot be downloaded to an EBL512 G3 control unit via Win512 version 2 7 x WinG3 version 1 1 x has to be used 89 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version
112. message FAULT Cut off The unit cannot be found by the control unit e Check the unit s COM loop address with the programming tool 3314 Check the downloaded site specific data SSD The unit might be faulty The detector might be removed from its base There might be a double break on the COM loop Note A single break gives the fault message FAULT Cut off FAULT No reply alert annunciation unit XxxX Control unit xx FAULT No reply external presentation unit 71 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Z CGOMEROl Wnt xx FAULT No reply fire brigade panel xx Control unit zx Alert Annunciation Unit 1735 1736 External Presentation Unit 1728 External Fire Brigade Panel 1826 1828 e The contact with the unit is interrupted Check the cable all connections etc Is correct complete SSD downloaded via Win512 version 2 7 x Check the address and SW mode settings Check if the Main board fuse F19 is broken Fuse T1 6A L 250V TR5 If there is a program memory fault in the unit there will be a fault message shown briefly in the unit s display during start up Memory fault in program area n n 1 or 2 The unit will not work ly alori ehoumbinealercaem winie poarcdi x COntrol unit sox ly external presentation unit Doard x COnCrol unit sx FAULT No reply fire brig
113. n Alarms queued P8 to scroll amongst the alarm points zone address or the soft key Next zone P5 to scroll amongst the zones NOTE Fire alarms are Fire alarm incl test mode alarm Heavy smoke heat alarm Alert Annunciation AA alarm Key cabinet alarm Acknowledged alarm New Zealand only 18 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Push buttons on the Fire Brigade Panel FBP Operation function Used to silence the buzzer in the c i e when it is sounding Used to silence alarm devices sounders in the building when they are sounding Silenced Alarm devices is indicated to the right in the display s soft key area a symbol near this button see page 22 Reset green Used to reset a Fire alarms see below Co incidence alarms if not automatically reset For more information see Alarm reset page 50 NOTE P3 has to be pressed for gt 0 5 sec The operation function is shown above the key in the display i e the soft key area The function of a soft key may vary depending on the situation If nothing is shown above the key in the display the key has no function for the moment Alarms queued grey Used when LEDs Alarms queued L6 are lit to scroll browse through the queued alarm points zone address Function see chapter Fire alarm page 40 under LEDs Alarms queued NOTE To scroll browse throug
114. n512 14 3 5 2 TLON Manager 15 3 5 3 Web512 II Config tool 15 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 4 Control Unit 16 5 LED indicators and push buttons 18 6 The display LCD 22 6 1 Areas in the display 22 6 2 The symbol area 22 6 3 The information area priority order 23 6 4 System information in the LCD 24 6 4 1 User definable system information 24 7 Access levels 25 7 1 Access level 1 26 Ad Access level 2A 26 73 Access level 2B 27 74 Access level 3A 28 7 5 Access level 3B 28 7 6 Access level 4 28 8 Silence Alarm devices 29 8 1 Silence alarm devices inside switch 29 8 2 New Zealand FB Silence switch outside switch 30 9 Disable Re enable alarm devices 32 10 Silence buzzer 33 11 Disable Re enable all control extinguishing and ventilation outputs 34 12 Evacuate 35 13 Open door 36 13 1 Outputs for routing equipment Fire brigade tx and Fault tx 36 14 Technical number Presentation number 37 14 1 Technical number for COM loop units 37 14 2 Presentation number 38 15 Alarm types 39 15 1 Pre warning 39 15 2 Firealarm eeseseses i i Oh 4 15 2 1 Enter the menu during fire alarm 43 15 2 2 Acknowledged and Isolated alarm 43 15 3 Heavy smoke alarm Heavy heat alarm 44 15 4 Alert Annunciation alarm AA alarm 45 15 5 Key cabinet alarm 45 15 5 1 Key cabinet opened before a fire alarm 46 15 5 2 Key cabinet opened
115. nning and are connected to the TLON network The TLON network programming has to be done It could take 90 120 seconds until this fault is corrected 512 The control unit current consumption is gt 2 5A gt 3 6A in alarm state and because of this the battery charging is turned off and will be so until the current consumption has decreased to lt 2 5A lt 3 6 A again 512 G3 The control unit current consumption is gt 3 3A gt 6 3A in alarm state and because of this the battery charging is turned off and will be so until the current consumption has decreased to lt 3 3A lt 6 3 A again EAU Cue COM Loce x COELO Wale sox This is indicating a single break on the loop Communication has to be performed in both directions to find all the units A double break will give the message FAULT No reply It can also be indicating a too long COM loop cable i e all units are not found until the communication is performed in both directions NOTE Communication in both directions lasts for about ten minutes before a new attempt to communicate in one direction is performed If the break remains a new ten minutes period starts and so on If the fault is acknowledged and the break is corrected during a ten minutes period it will not disappear from the list until the end of the ten minutes period AUIS We okki npu LSSO loeeuecl i k C xe 8 zones expansion board DET8 61 Panasonic Eco Solutions Nor
116. number often the type no and sometimes is a country code added e g 5010SE e aproduct name e g Main Board 128 alarm points e ap c b number e g 9290 3B and can also have a configuration e g CFG 2 and a revision e g REV 2 e sometimes a S W S W A S W has e aversion number e g United version 2 7 x Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x e sometimes additional information such as Convention different functions facilities Language Number of addresses etc PC S W A PC S W is a program used for programming commissioning etc It has a version number Panasonic Eco Solutions Nordic AB MEW01473 2 Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Definitions Explanations 2 1 2 2 2 2 1 2 2 2 2 2 3 2 2 4 2 2 5 2 2 6 2 2 7 Definitions explanations abbreviations etc frequently used or not explained elsewhere in the document PESN AB Panasonic Eco Solutions Nordic AB Alarm points Units which can generate a fire alarm in the control unit i e analog detectors sensors conventional detectors manual call points etc Smoke detector Analog and conventional photoelectric optical smoke detectors are available Sensor Sensor Analog detector Analog detector Contains an A D converter The Control Unit pick up the digital v
117. o GIL ae Wow Short circuit on COM loop x short circuit isolator is not connected on the loop Check the loop NOTE As long as there is a short circuit the COM loop is disabled Each 10 minute is an attempt made to re enable the loop again PAULE SM Cire input x ISS loveeuecl x CU 8 zones expansion board DET8 This is indicating short circuit on input x zone line on the 1580 board The wires cable might have been damaged NOTE As long as there is a short circuit the zone is disabled Each minute is an attempt made to re enable the zone again BAUTIS TSNOr tiere loos x BS4 x CU vox 1584 Autronica interface board BS4 Short circuit or current consumption gt 167mA on the BS4 loop short circuit isolator is not connected on the loop Check the loop NOTE As long as there is a short circuit the BS4 loop is disabled Each 10 minute is an attempt made to re enable the loop again Hy gt Ux CU AS hO U xx ASFO lt gt ASF1 UW Sok ASIF I ASRA xx ASF2 lt gt ASF3 U xx ASF3 lt gt ASF4 U xx ASF4 lt gt ASF5 U xx ASF5 lt gt ASF6 WME oh eire loop x CU sox ASEO ASE orts cha reire leoo Kp CU sok ASPI CU ULES Sin caice looo lt CU x ASBO lt SCU Uit ES Sinai oop Hy gt Urt Sh eire keels 2 Hy gt ULE sSiaeanee LoCo x Hj gt We on eire Ieee x Hy gt Uit Sin erniae Iecis x Hy gt Urt oh eire loop x j gt We Sa etre Looe x
118. og U7 Information Scroll to menu U5 U5 Sensors activating SERVICE signal m Sensor Zone ZZZ address AA needs service A list in which you can technical address xxxxxx scroll with Y or A n If printer is mounted the Sensor Zone ZZZ address AA needs service soft key Print will be technical address xxxxxx visible else not Press 2010 02 03 19 09 35 Print for a print out of all items in the list If there are no sensors Number of sensors xx having generated SERVICE signal when ee a i d the list eas 1S eas the lis view will not open ESC U5 Sensors activating SERVICE signal Scroll to another menu or press ESC NOTE During printing Print will be replaced with Abort printing 124 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 27 6 Event log H4 U6 Three event logs 3 x 999 events are available 1 Alarm log alarm events e g fire alarm fire alarm reset etc 2 Interlocking log only interlocking events 3 General event log all other type of events The origin of the event e g CU00 see below can instead be Win512 Web512 or Ext External system no connected via Web server Menu According to chapter Access see page 98 Scroll to menu H4 H4 Present system status Mas U1 Disablement U2 Disablement by time channel U3 Open doors U4 Sensor values U5 Sensors activating SERVICE signal U
119. on download page 89 e Use WinG3 version 1 1 x to upgrade the maximum number of alarm points 128 gt 256 gt 512 see below NOTE In a mixed system the maximum number of alarm points is equal to the maximum number of COM loop addresses e Use WinG3 version 1 1 x to download the software for use in a mixed system i e EBL512 G3 United version 2 7 x How to change the maximum number of alarm points Connect the PC via USB to the EBL512 G3 control unit Start WinG3 version 1 1 x open a new installation and add a control unit with correct control unit number 1 Logon Tools Log on Control unit 2 Select the control unit icon right click and in the pop up menu select Upgrade number of alarm points A dialog box opens a ny Upgrade Erima Serial number Set number of alarm points 128 X Enter password 3 Click Read to get the Serial number for the control unit you are connected to as well as the valid number of alarm points 4 Report the Serial number to the producer in order to get a password 5 Write the new number of alarm points and the received password in the field respectively and click Write Follow the same procedure in each control unit 2 Software EBL512 G3 United version 2 7 x 4 To upgrade the maximum number of alarm points a special PC program is used to generate a password The password will be unique for every serial number and number of a
120. on the main board 5010 x 1 S1 Short circuit break on the connected cable equipment and or blown fuse F5 on the main board 5010 x 2 S2 Short circuit break on the connected cable equipment and or blown fuse F6 on the main board 5010 x 3 S3 Short circuit break on the connected cable equipment and or blown fuse F7 on the main board 5010 Fuse T500mA L 250V TRS Calibration not performed via menu H5 A1 Connected equipment might be stolen Resistor s missing or not correct value 1 5 resistors 33K NOTE The calibrated value has to be in the range 4K7 50K This fault message is valid for a COM loop output unit 3364 output If the output is programmed for sounders type Alarm devices it is also indicated by LED Fault Disablements Alarm devices blinking If the output is programmed for fire brigade tx type Routing equipment it is also indicated by LED Fault Disablements Fire brigade tx blinking Calibration not performed via menu H5 A1 Short circuit break on the connected cable equipment Connected equipment might be stolen End of line capacitor s missing or not correct value 1 5 capacitors 470 nF NOTE The calibrated value has to be in the range 470 nF 5 x 77 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 470 nF 2350 nF FAULT Temperature sensor control unit xx The sensor
121. onic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 28 2 Calibration of supervised outputs H5 A1 Supervised monitored outputs The voltage outputs SO S3 in each control unit The voltage outputs VOO VO1 in the COM loop output unit 3364 When all alarm devices sounders etc have been connected including required end of line devices and when the SSD is downloaded a calibration has to be done Function The calibrated range is 4K7 50K and 470 5x470 nF respectively If the actual value at any time differs from the calibrated value a small tolerance or if the calibrated value is outside the calibration range a fault will be generated Text in display Comments Menu According to chapter Access code for service and maintenance H5 and H8 see page 129 Calibration in progress Please wait A1 Calibration of supervised outputs Calibration is ready Scroll to another menu or press ESC Sensitive fault detection mode Service mode for COM loop Display current consumption in unit Display current consumption on COM loop Display statistics for communication Activate address setting mode for DU Service mode for BS4 loop Display current consumption on BS4 loop NOTE After the calibration it is recommended do a Safe shutdown of the control unit see menu H8 S6 This will save the SSW data e g the calibration values in a Flash ROM see
122. ons Fire alarm system EBL512 G3 United version 2 7 x 26 Set calendar and clock H3 The RTC component has a capacitor as a backup power supply Normally date day of the week and time only have to be set when the power is turned on the control unit for the first time If required the clock might be corrected so that the time stamps for fire alarms faults etc will be correct The calendar and clock can be set in any c i e for the whole system Every day at midnight the calendar and clock will be synchronised NOTE If you don t want to change anything press ESC instead of lt to return to menu H3 Menu According to chapter Access see page 98 Scroll to menu H3 WEER Eao Koo aaa YYWy MM DD hh mm The date amp time shown Tuesday was valid when this menu Wednesday was opened When Thursday required change the date Friday time and or weekday Saturday press Y or A to Sunday select the weekday The clock starts again as from the date time etc shown in the display when you press lt If no changes shall be done press ESC instead of van H3 Set calendar and clock Scroll to another menu or press ESC NOTE When the Russian Ukraine Australian or the New Zealand language is selected the date is shown as follows DD MM YYYY The capacitor can supply the RTC for a couple of days When the power has been turned off it is recommended to check set the date
123. or set another time max 24 hours select Yes and press 2 to disable with automatic re enablement 105 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Disable zone oo address 00 LED Fault press lt Disablements General disablements L10 will light up Disable another zone or press ESC Scroll to another menu or press ESC 106 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 25 3 Disable output H2 B3 All outputs can be individually disabled Disabled output will stay in or return to the normal condition for the output respectively Disabled outputs are listed in menu H4 U1 from which it is also possible to get a print out Menu According to chapter Access see page 98 Scroll to menu H2 H2 Disable or re enable n lt n B2 Disable zone address Disable output Re enable zone Re enable zone address Re enable output Disable re enable output type Disable re enable alarm devices Disable re enable routing equipment B10 De activate alert annunciation function Scroll to menu B3 B3 Disable output di Disable output type 36 1 3364 Select output type S 3361 3364 also used for R RU4 SU4 outputs conn to Expansion board EBLS512 R CU relay output RO R1 Press lt to accept d S CU voltage outp
124. ortant information suppresses less important In some cases also valid for the symbol area The priority order is is visible Routing equipment left isolated NOTE Fire alarms are Fire alarm Heavy smoke heat alarm Alert Annunciation AA alarm Key cabinet alarm Acknowledged alarm New Zealand only Isolated alarm New Zealand only The different type of events and the menu system are described in other parts of this document Regarding System information see 6 4 7 The AAF function is used in conjunction with an AAF Control which is available on the Australian market only 23 Panasonic Eco Solutions Nordic AB MEW01473 6 4 6 4 1 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x System information in the LCD EBL512 G3 control unit number date and time are displayed The exact look is convention language dependent One example EBL512 G3 Control Unit XX yyyy mm dd hh mm yyyy mm dd Date Year Month Day Control Unit XX 00 29 hh mm Time hour minute NOTE When the Russian Ukraine Australian or the New Zealand language is selected the date is shown as follows dd mm yyyy User definable system information User definable system installation information created and downloaded via Win512 can be displayed in the middle of the display One row a 40 characters is available This information is shown in all control units in the system One e
125. ot visible for the test personnel are disabled In order to shorten the testing time any time delay for the detectors zones in test mode will be disabled i e fire alarm will be detected faster than normally In the tested alarm point the LED will light up and the LEDs Fire L1 in the c i e will light up approx 10 seconds then the alarm point will be automatically reset The printer if available will print out every tested alarm point Zone xxx Address xx Time HH MM A sensor in test mode will not be able to activate fault 143 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x After 60 minutes or Zones in test mode You are no longer in menu Esc Menu 001 002 003 004 End test H7 but still in test mode NOTE See chapter The information area priority order page 23 regarding priority order When required Zones in test mode Press 4 to end test Menu code 001 002 003 004 End test Scroll to menu H7 a Please wait H7 Perform ZONE TEST The LED Test mode L8 is turned OFF If more zones are to be tested continue as above If not scroll to another menu or press ESC NOTE_1 During the test the following information will be shown in all other c i e displays Zones in test mode 001 002 003 004 NOTE_2 If an alarm point e g a manual call point is in alarm state when the tes
126. output Menu C3 is a list in which area Mot point 10 you can scroll If there are area 001 point 11 area 001 point 12 no activated outputs menu C3 will not open Press lt to reset the selected output Escape P Reset All Press Reset All to reset menu fimReset All r all interlocking outputs Press ESC to menu C3 C3 Reset interlocking output Scroll to another menu or press ESC 164 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 32 4 Disable interlocking output H9 C4 Interlocking outputs Type Interlocking can be individually disabled via this menu but not via menu H2 B3 All interlocking outputs can be collectively disabled by entering 000 00 The Interlocking Combination Area Point is to be entered to disable the output Up to 200 interlocking outputs can be disabled Disabled interlocking outputs are listed in menu H4 U1 from which it is also possible to get a print out The LED Fault Disablements General disablements L10 is also indicating one or more disabled interlocking outputs oo Access see page 98 om C2 Activate interlocking output C3 Reset interlocking output C4 Disable interlocking output C5 Re enable interlocking output Scroll to menu C4 C4 Disable interlocking output a Disable interlocking output Write the area number and area doo point 00 point and press lt pres
127. p when you close the control unit door 103 Panasonic Eco Solutions Nordic AB MEW01473 25 1 Menu Scroll to menu H2 n lt n Write the zone number e g 001 n lt n Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Disable zone H2 B1 When a whole zone is disabled all alarm points within the zone will be disabled except the addressable manual call points Not valid for the Australian and New Zealand conventions Disabled zones are listed in menu H4 U1 from which it is also possible to get a print out According to chapter Access see page 98 H2 Disable or re enable B2 Disable zone address Disable output Re enable zone Re enable zone address Re enable output Disable re enable output type Disable re enable alarm devices Disable re enable routing equipment B10 De activate alert annunciation function Disable zone loo press lt Disable zone o1 Press lt to disable press lt Re enable time H MM Press to disable without automatic re Yes enablement Default is current time 3 hours or Accept the time 3 hours or set another time max 24 hours select Yes and press 2 to disable with automatic re enablement Disable zone loo LED Fault press lt Disablements General disablements L10 will light up Disable another zone or press ESC Scroll to another menu or press ESC 10
128. page 112 34 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 12 Evacuate When the soft key Evacuate P7 is pressed all outputs programmed for sounders i e type Alarm devices will be collective turned ON steady This is indicated in the LCD The sounders will remain turned ON until they are turned OFF by pressing the soft key Evacuate off P7 NOTE 1 The alarm devices sounders will always be activated steady sound continuously irrespective of the fact that the outputs can be set to anything else for fire alarm e g intermittent NOTE 2 The text Menu above the soft key P4 is visible in the display only if the door in the c i e is open while the text Evacuate Evacuate off above P7 is always visible in the current conventions NOTE 3 The outputs will be turned ON even if they are disabled 14 The soft key Evacuate is only visible valid for the Belgian British Standard Hungarian Spanish and Ukrainian conventions S Alt when a programmable input is activated One input per c i e 16 Alt when the programmable input is de activated 35 Panasonic Eco Solutions Nordic AB MEW01473 13 Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Open door 13 1 A special key is used to open the control unit door to get access to the front system The same type of key i
129. page 154 58 Control unit outputs SO S3 One end of line resistor 33K in the last unit or one resistor 33K in up to five units 3364 outputs VOO VO1 One end of line capacitor 470 nF in the last unit or one capacitor 470 nF in up to five units 130 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 28 3 Sensitive fault detection mode H5 A2 To increase the possibilities to detect faults during the commissioning it is possible to use the Sensitive fault detection mode The time delay for each fault will then be reduced i e you might find some faults now instead of in the future The Sensitive fault detection mode turned on is indicated by the LED Routing equipment Fault tx activated L13 and the Fault output for routing equipment is activated NOTE Don t forget to turn off this mode after the commissioning Text in display Comments Menu According to chapter Access code for service and maintenance H5 and H8 see page 129 ma Sensitive fault detection mode Service mode for COM loop Display current consumption in unit Display current consumption on COM loop Display statistics for communication Activate address setting mode for DU Service mode for BS4 loop Display current consumption on BS4 loop Scroll to menu A2 A2 Sensitive fault detection mode a Sensitive fault detection mode Ojjj Press to turn off or
130. personnel only must do this Used incorrectly it can cause nuisance fire alarms The first week average sensor value after clearing will be calculated within one hour then each week Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page 129 ale S1 Disconnect loop zone line input Re connect loop zone line input Acknowledge SERVICE signal Clear weekly average Test of alarm devices Safe shut down of control unit Activate address in alarm mode Synchronize the control units Change code for service maintenance S10 Change code for PC communication Scroll to menu S4 S4 Clear weekly average ad Clear weekly average zone loo address 00 Write the wanted zone and press address and press lt ESC S4 Clear weekly average Continue like above or scroll to another menu or press ESC 151 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 31 6 Test of alarm devices H8 S5 The programmable outputs of type Alarm device can be collectively activated via this menu H8 S5 which makes it possible to test the alarm devices The test cannot be started if a fire alarm already is activated in the system One or all control units can be selected When the test starts the alarm devices will sound continuously steady for approx 5 seconds be silent for approx 25 seconds sound
131. play units NOTE WinG3 version 1 1 x is however used for download software to an EBL512 G3 control unit TLON Manager TLON Manager is used for the TLON Network programming Web512 Il Config tool The EBL512 G3 United version 2 7 x software is used for an EBL512 G3 control unit in a mixed system see chapter Mixed system page 12 For this reason Web512 II Config tool version 2 7 x is used for configuration of the Web server II 1598 15 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 4 Control Unit Figure 1 Left The EBL512 G3 Control Unit 5000 with printer The look might vary according to configuration country etc Right The EBL512 G3 Control Unit 5001 Depending on country convention configuration etc the look language and functions might vary Figure 1 shows an EBL512 G3 type 5000 with a front with texts in English Fronts with texts in other languages are available EBL512 G3 is housed in a grey metal cabinet The door has a Plexiglas ahead of the front and display see Figure 1 A key is required to open the door to get full access to the push buttons on the front i e the Fire Brigade Panel FBP and the Control Panel CP EBL512 G3 type 5001 has no front display and printer and is housed in a grey metal cabinet without a door 16 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm s
132. r actions programmed via Win512 version 2 7 x which can be used e Another alarm algorithm can be used e g during working hours e Alarm delay for smoke detectors sensors can be used e Two zone or two unit dependent co incidence fire alarm activation can be used e Inan installation with addressable detectors sensors e g EBLS512 G3 the affected detectors can be individually disabled or whole zones for temporary work in the premises Bear in mind that the smoke spreads and consideration must be taken to adjacent detectors zones Disablements can be done automatically via a time channel built in or external or via menu H2 B1 B2 Automatic re enabling can be used e If there is an alarm organisation for the personnel on site the alert annunciation function can be used e Pre warning can be used as information before a fire alarm is activated 173 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 39 Information regarding radioactive radiation source Today Panasonic have no ionization smoke detectors but old detectors connected to the EBL512 G3 installation might be old smoke sensors detectors of the ionization type They contain a small radioactive radiation source normally Americium 241 When these sensors detectors gets dirty and when service signal has been activated in the system contact your local dealer for clean
133. r different manoeuvres The CP has several LEDs for system status In the Australian front only below the P3 button there is also a Disable push button with which you can Disable zones in alarm 17 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 5 LED indicators and push buttons LEDs and push buttons can vary according to type and configuration convention country language See also Figure 2 page 17 LED indicators on the Fire Brigade Panel FBP LED indicator Indicating L1 Fire 5 red Fire alarms see below Quiet alarm normally Australia only See also chapter Alarm types page 39 Extinguishing red Output s for extinguishing equipment activated Or a programmable input type Extinguishing is activated ea Ventilation yellow Output s for fire smoke ventilation equipment activated Or a programmable input type Ventilation is activated Fire brigade tx red Output Fire alarm for fire brigade tx routing equipment and or corresponding programmable output s of type Routing equipment is are activated Or a programmable input type Activated routing equipment is activated Test of routing equipment in progress see menu H1 Operation green The c i e is powered via the rectifier and or the battery Alarms queued 2 red More than one alarm point zone have activated fire alarm Use push butto
134. r service and maintenance H5 and H8 see page 129 a Sensitive fault detection mode Service mode for COM loop Display current consumption in unit Display current consumption on COM loop Display statistics for communication Activate address setting mode for DU Service mode for BS4 loop Display current consumption on BS4 loop Scroll to menu A7 A7 Activate address setting mode for DU al Activate address setting mode for DU Write control unit number Control unit io 1587 board 0 display unit 00 All 1587 board no only for EBL512 and the unit s address or select press p All Le all display units on the selected control unit 1587 board a A7 Activate address setting mode for DU Scroll to another menu or press ESC The address is thereafter edited in the display unit DU respectively 138 Panasonic Eco Solutions Nordic AB MEW01473 28 9 Action Menu Ei Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Service mode for BS4 loop H5 A8 NOTE The following is valid only for an EBL512 control unit with one or more BS4 boards 1584 If the control unit number CU XX is valid for an EBL512G3 control unit this menu is not valid The communication direction is normally automatically changed every minute to ensure that the wires are okay all the way To make trouble shooting easier e g during the commissioning it is possible to lock the commun
135. r supply is okay rectifier and or battery The c i e will now restart see chapter Restart page 94 The site specific data SSD created in Win512 version 2 7 x can now be downloaded see chapter Programming SSD download page 87 See also chapter Calibration of supervised outputs H5 A1 page 130 Cable tie shall be mounted to keep the mains wires well separated from the 24 V DC wires Follow National regulations 83 Panasonic Eco Solutions Nordic AB MEW01473 18 2 18 2 1 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Control Units ina TLON network In a TLON network there is two or more control units connected A TLON connection board 1590 5090 is required in each control unit connected to the network One TLON connection board 1590 5090 has to be plugged in each control unit Network no 0 3 Network no 0 When the 1590 5090 board is on place and the network cables are connected for each control unit do as for a single control unit see 1 6 above When all control units are powered the TLON network installation see below has to take place before the site specific data SSD can be downloaded see chapter Programming SSD download page 87 If you know that one or more of the control units are to be started up later do as follows In Win512 version 2 7 x create the SSD only for the control units that shall be connected now Wait
136. ral control units connected in parallel i e the board is used for Redundancy in distributed system The input x is in fire alarm state but there is no activated fire alarm in any control unit and no fault on the TLON Network Check the connections e g of the alarm resistor in the slave unit units PAUDI Alarm input cechi NO XXX XX The zone line input Input 0 on the 3361 unit with technical number XXXXXX is used for a single slave unit control unit or several slave units connected in parallel i e the unit is used for Redundancy in distributed system 58 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x The Input 0 is in fire alarm state but there is no activated fire alarm in any control unit and no fault on the TLON Network Check the connections e g of the alarm resistor in the slave unit units AUIS INS ICOM IOC x CONE rO basic xox ASF 2370 Addressable short circuit isolator This message is only shown when the control unit works in Sensitive fault detection mode menu H5 A2 A short circuit shorter faster than the time delay for an ordinary fault has occurred on the COM loop Can be used for commissioning maintenance purposes Batteries 2 x 12 V are missing or not connected correctly Fuse es F2 F3 on the charger board 1557 1657 is are blown Other battery fuse is blown e g when the bat
137. rating Instructions Fire alarm system EBL512 G3 United version 2 7 x 27 4 Sensor values H4 U4 The very first week average sensor value is calculated within 2 minutes after SSD download amp restart During these 2 minutes can no fire alarm be activated and the Weekly value 00 0 will be shown The Performance factor and Min Max values are updated each night 00 00 i e the values shown are from the previous day Menu According to chapter Access see page 98 Scroll to menu H4 H4 Present system status ma U1 Disablement U2 Disablement by time channel U3 Open doors U4 Sensor values U5 Sensors activating SERVICE signal U6 Event log U7 Information Scroll to menu U4 U4 Sensor values Wl n Start sensor fooo00 Write the technical number and or press lt to start as from sensor 000001 a When 4 is pressed the sensor values will be shown in the A list in which you can display An examples which shows the values from an analog scroll with Y or A multi detector 4300 and an analog heat detector 3308 if printer 8 mounted the soft key Print will be Sensor 001 01 technical address 000001 visible E Demot Biss Momentary XX X m Weekly XX X m Perf factor X XX m Min XX X m If there are no sensors Algorithm X XX Max XX X m analog detectors when Momentary XX C Min XX C lt is pressed the list Algorithm XX Max XX C view will not open Print for a pr
138. rity reasons the default code should be changed NOTE This code requires eight 8 digits Text in display Comments Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page 129 a S2 Re connect loop zone line input Acknowledge SERVICE signal Clear weekly average Test of alarm devices Safe shut down of control unit Activate address in alarm mode Synchronize the control units Change code for service maintenance 10 Change code for PC communication Scroll to menu S10 S10 Change code for PC communication a Access code New code Verify Enter the old code the Access code The digits are replaced by new code and the new New code kkkkkkkk Verify Saaki He oe ae akak ak ak ae in the display code again Incorrect access code NO change The access code was not correct Try again S10 Change code for PC communication The access code was correct and is now changed to the new code Scroll to another menu or press ESC NOTE After change of access code it is recommended do Safe shutdown of the control unit see menu H8 S6 This will save the SSW data e g the new code in a Flash ROM see page 154 161 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 32 Interlocking outputs and inputs H9 32 1 Activated interlocking outputs inputs H9 C1 Te
139. rmal fire alarm see above except for the c i e output for routing equipment fire brigade tx which will not be activated directly There will also be a title i e Alert annunciation or Alert annunciation acknowledged will be added to the normal fire alarm information The AA alarm has to be acknowledged within an acknowledge time and reset within an investigation time otherwise the output s for routing equipment fire brigade tx will be activated See EBL512 G3 Planning Instructions for more information regarding the AA function Acknowledgement and reset of the AA alarm can be done on an AA unit 1735 1736 or an AA controller 1740 See also chapter Alert Annunciation page 52 15 5 Key cabinet alarm The fire brigade uses a key cabinet to store a key to the building 45 Panasonic Eco Solutions Nordic AB MEW01473 15 5 1 15 5 2 15 5 2 1 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x One programmable input per c i e can be used to connect a key cabinet Key cabinet opened before a fire alarm If the key cabinet is opened before a fire alarm e g if somebody illegally breaks into the key cabinet a key cabinet alarm will be activated Example Key cabinet alarm xx Control Unit number 00 29 First alarm 000 00 Alarm number 1 of 1 Alarm from key cabinet control unit XX When printer is available the Key cabinet alarm will be printed like a normal fire
140. rs i e type Alarm devices will be turned OFF de activated If the push button Silence alarm devices is pressed again the sounders will automatically sound again In case of a new alarm the sounders will automatically sound again Silence alarm devices inside switch NOTE The functions in this chapter are normally used in New Zealand The button Silence alarm devices P2 is called the inside switch and has the following function The inside switch toggles between two states e Alarm devices disabled All programmable outputs of type Alarm devices are disabled i e they cannot be activated e Alarm devices not disabled All programmable outputs of type Alarm devices are enabled i e they can be activated If the inside switch is in its disabled state when the c i e door is being closed the buzzer will beep steady continuously and the message Silence switch left active will be shown in the display For priority order see chapter The information area priority order page 23 NOTE The inside switch has no function if the outside switch see below is activated ON 10 E g during Fire alarm or Alert Annunciation alarm Including Addressable siren 3377 Addressable sounder base 3379 and Addressable beacon 4380 29 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 8 2 New Zealand FB Silence switch o
141. s 000 00 All interlocking outputs If more interlocking outputs shall be disabled continue the same way Press ESC to menu C4 2 disable C4 Disable interlocking output Scroll to another menu or alt press ESC ESC 165 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 32 5 Re enable interlocking output H9 C5 Disabled interlocking outputs are listed in menu H4 U1 from which it is also possible to get a print out Interlocking outputs Type Interlocking can be re enabled via this menu but not via menu H2 B6 If all interlocking outputs have been collectively disabled via 000 00 in menu H9 C4 they have to be re enabled via this menu and 000 00 er Access see page 98 Tae C2 Activate interlocking output C3 Reset interlocking output C4 Disable interlocking output C5 Re enable interlocking output Scroll to menu CS C5 Re enable interlocking output Re enable interlocking output This is a list in which you aren ot point 01 can scroll If there are no area 004 point 01 disabled outputs menu C5 will not open 000 00 All interlocking outputs Press lt to re enable the selected output Press ESC to menu C5 a PA Re enable interlocking output Scroll to another menu or alt press ESC area 04 point 01 ESC o p 166 Panasonic Eco Solutions Nordic AB MEW01473 Rev
142. s Fire alarm system EBL512 G3 United version 2 7 x 31 4 Acknowledge SERVICE signal H8 S3 When SERVICE signal is generated in the system following symbol is shown in the display s symbol area L See also chapter Sensors activating SERVICE signal H4 U5 page 124 When service signal from a sensor is acknowledged the sensor is given a default week average sensor value same as for a new clean sensor i e 1 i e first replace the sensor and then acknowledge the service signal as soon as possible The first week average sensor value after acknowledge will be calculated within one hour then each week NOTE If a sensor is replaced without having generated service signal it has to be reset to the default week average sensor value via menu H8 S4 page 151 Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page 129 S2 Re connect loop zone line input S3 Acknowledge SERVICE signal S4 Clear weekly average S5 Test of alarm devices S6 Safe shut down of control unit S7 Activate address in alarm mode S8 Synchronize the control units S9 Change code for service maintenance 10 Change code for PC communication Scroll to menu S3 S3 S3 Acknowledge SERVICE signal sid SERVICE signal Sensor Zone ZZZ address AA needs service This is a dynamic list in technical address xxxxxx which you can scroll 2009 12 03 09 09 15 Use V or A to select a sensor the selected S
143. s Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 12345678901 23456789012345678901234567890 First alarm 002 03 Alarm number 1 of 1 ISOLATED alarm Zone Address 002 03 svo User definable alarm text for 002 03 31 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 9 Disable Re enable alarm devices Outputs programmed for sounders i e type Alarm devices can via menu H2 B8 be collective disabled for one several or all control units This is indicated by LED Fault Disablements General disablements L10 and Alarm devices L11 which are steady ON In case of a fire the sounders will remain disabled i e the alarm devices will not sound until they are re enabled again via menu H2 B8 See also chapters Disable output H2 B3 page 107 and Disable re enable alarm devices H2 B8 page 114 32 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 10 Silence buzzer The buzzer in the control unit will sound for Fire alarm 0 4 0 4 sec Co incidence alarm 2 zone or 2 unit dependent fire alarm When only one zone or one zone address alarm point is in alarm status 0 8 5 sec Pre warning 0 8 5 sec Quiet alarm 0 8 5 sec Fault continuous Disablements and Fau
144. s Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 17 Fault All faults are delayed in order not to generate any unnecessarily faults e g for COM loop and zone line input faults the delay time is approx 45 seconds 7 In case of a fault condition the following will happen in the c i e e The buzzer in the c i e will sound continuously steady e The fault condition output for routing equipment Fault tx will be activated e Programmable output s for general fault will be activated and output s for general charge fault might be activated e LED Routing equipment Fault tx activated L13 will be turned on indicating that the fault condition output for routing equipment Fault tx is activated e LED Fault Disablements General fault L9 will be turned on e LEDs Fault Disablements Alarm devices L11 System fault L7 and or Fault Disablements Fire brigade tx L12 might be turned on as well e A fault message incl date time and status will be shown in the c i e display Example fault message FAULT No reply zone xxx address xx technical number xxxxxx yyyy mm dd hh mm serviced Number of not ackn faults in system 1 Menu NOTE When the Russian Ukraine Australian or the New Zealand language is selected the date is shown as follows dd mm yyyy 7 Some units may also have an internal delay time which makes the delay tim
145. s also used to open the ext FBP door If any door in the system is open the following symbol is shown in the Set H display s symbol area See also chapter Open doors H4 U3 page 121 Outputs for routing equipment Fire brigade tx and Fault tx Via Win512 version 2 7 x the following can be programmed default settings shown Disable routing equipment by door switch None Open door in a C U or an ext FBP will not disable the output s for routing equipment Fire brigade tx and fault tx O Any control unit door Open door in any C U will disable the output s for routing equipment Fire brigade tx and fault tx in all C U s O Any door Open door in any C U or any ext FBP will disable the output s for routing equipment Fire brigade tx and fault tx in all C U s Disabled outputs for routing equipment are indicated by the LEDs Fault Disablements General disablements L10 and Fire brigade tx L12 and listed in menu H4 U1 36 Panasonic Eco Solutions Nordic AB MEW01473 14 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Technical number Presentation number 14 1 Technical number for COM loop units The technical number NNNNNN is used when programming all units connected to the COM loops Technical number is also used to identify which unit has generated a fault NN N NNN 001 127 The technical address on the COM loop The a
146. sssssssssssss Downloaded YYYY MM DD hh mm Control unit NN Escape menu U7 Information Scroll to another menu or press ESC 127 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 28 Service H5 When commissioning an installation and by maintenance e g when you power on and when you are programming a control unit system menu H5 can be used for certain information and help Only authorised personnel have access to the level 3A menus Access code for level 3A is required Via a PC and Win512 version 2 7 x access code for level 3B you can e download backup upload the site specific data SSD e create and download software S W settings configurations control unit and system properties e create and download the user definable text messages alarm texts shown in the display in the control unit ext FBP and other Display units Via a PC and TLON Manager you can create and download install the TLON network configuration project Has to be connected to the RS232 connector J1 in an EBL512 control unit 7 Connected to the modular connector J10 for TLON network 0 in an EBL512 G3 control unit or J2 in an EBL512 control unit 128 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 28 1 Access code for service and main
147. sumption Valid for Charger board 1657 512 G3 The fault is activated 1 300 minutes after Loss of mains i e no 230 V AC e Blown mains fuse e Blown fuse F1 on main board 5010 Fuse T6 3A H 250V 5x20 mm ceramic 69 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x The delay time 1 300 minutes is the same as programmed for the control unit see above This fault is valid for external power supply equipment which has a fault output connected to a programmable input in the EBL system The fault is activated 1 300 minutes after the input is activated e Loss of mains i e no 230 V AC to the ext power supply equipment e Blown mains fuse e Check the programmable input connections The delay time is the same as for the control unit see above This fault is valid for the external power supply unit 3366 and the addressable 2 voltage outputs unit 3364 connected on the COM loop The fault is activated after 1 300 minutes after Loss of mains i e no 230 V AC to the 3366 unit e Blown mains fuse Fuse F1 blown on the 3366 unit s charger board 3367 Fuse T5A L 5x20 mm 3364 unit o Terminal no 8 Mains OK not connected to the 3366 unit J7 4 or 0 V o No mains signal from the 3366 unit FAULT Multiple faults COM 1l00p x Contao MNE Break cut off short circuit in more than one segment on the COM loop in control
148. system EBL512 G3 United version 2 7 x 25 10 De activate Alert Annunciation function H2 B10 Normal function For alarm points zones programmed for Alert Annunciation via Win512 version 2 7 x is normally the AA function enabled via a time channel e g enabled daytime during working hours and disabled night time As an alternative the AA function can be continuously enabled Off Via this menu H2 B10 it is possible to de activate continuously disable the AA function i e the AA function will be disabled for the alarm points zones programmed for Alert Annunciation in spite of the time channel is on or if they are programmed to be continuously enabled The AA function will stay de activated disabled until re activated re enabled again via this menu Menu According to chapter Access see page 98 Scroll to menu H2 H2 Disable or re enable n lt n Disable zone address Disable output Re enable zone Re enable zone address Re enable output Disable re enable output type Disable re enable alarm devices Disable re enable routing equipment B10 De activate alert annunciation function Scroll to menu B10 B10 De activate alert annunciation function ma Alert annunciation function Noldan Select Normal or Off Off B10 De activate alert annunciation function Scroll to another menu or press ESC 117 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructi
149. t mode is ended there will not be a fire alarm activated Instead the alarm point will be disabled and has to be re enabled again via menu H2 B5 NOTE_3 When the Fire door closing function is used the fire door will be closed when the detectors controlling the door are tested in test mode 144 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 31 Maintenance H8 31 1 Access code for service maintenance Access code to level 3A is required for menu H8 31 2 Disconnect loop H8 S1 Before physical connection disconnection of loop units etc the loop or zone line shall be disconnected disabled i e there will be no voltage on the loop to avoid damage on the units and the c i e Zone line input requires an 8 zones expansion board 4580 1580 in the control unit an Addressable multipurpose I O unit 3361 or an Addressable zone interface 2226 2335 2821 connected on a COM loop Menu Procedure according to chapter Access code for service and maintenance H5 and H8 see page 129 S1 Disconnect loop zone line input S2 Re connect loop zone line input S3 Acknowledge SERVICE signal S4 Clear weekly average S5 Test of alarm devices S6 Safe shut down of control unit S7 Activate address in alarm mode S8 Synchronize the control units S9 Change code for service maintenance 10 Change code for PC communication mon Disconnect
150. t the Plexiglas in the door is provided with a hole for access to the Alarms queued button P8 see Figure 1 page 16 Normally a person on site trained in order to perform monthly tests dis ablements etc 25 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 7 1 Access level 1 With the door closed anybody has access to the push button Alarms queued P8 to scroll browse through the queued alarms 7 2 Access level 2A A After the door has been opened Door open symbol E in the symbol field the user fire brigade personnel have access to the push buttons keypad to do the following Push Operation function button P i P2 Silence all alarm devices sounders P3 Reset fire alarms see below NOTE Fire alarms are Fire alarm incl heavy smoke heat alarm Alert Annunciation AA alarm Key cabinet alarm Co incidence alarm if not reset automatically Acknowledged alarm New Zealand only Isolated alarm New Zealand only Silence the buzzer in the c i e 26 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 7 3 Access level 2B J After the door has been opened Door open symbol in the symbol field the building occupier has access to level 2A and after access code for level 2B or 3A access to the following menus C2
151. ted alarm point Zone xxx Address xx Time HH MM A sensor in test mode will not be able to activate fault After 60 minutes or Zones in test mode You are no longer in menu Esc Menu 001 002 003 004 End test 4 H1 but still in test mode NOTE See chapter The information area priority order page 23 regarding priority order When required Zones in test mode Press lt 4 to end test Menu code 001 002 003 004 End test Test of routing equipment The LED Test mode is turned OFF Yes Some national regulations also require a routine test of the routing equipment Press press 4 i e select No for no test If so the monthly test is completed see below or Press Y and lt i e select Yes to start such a test If so the following will happen in the system e The c i e Fault tx output will be de activated note that this output is activated in normal state indicated by the LED Fault tx activated L13 60 seconds count down starts e After 30 seconds also the c i e Fire brigade tx output and corresponding programmable outputs type routing equipment will be activated indicated by the LED Fire brigade tx L3 e After another 30 seconds the test will be ended and the outputs and LEDs will return to normal W and 4 Test of routing equipment in progress nn starts at 060 and will nnn seconds left count down to 000 Monthly test is completed Press J Scroll to another menu or
152. tenance H5 and H8 Access code to level 3A is required If login to level 2B was made with code for level 3A no code is required here Text in display Comments Menu According to chapter Access page 98 Scroll to menu H5 or MEIA H8 f H8 Maintenance a Access code If login was made with code for level 3A no code is needed Enter code for level Access code The digits are replaced 3A 4 digits with in the display NO ACCESS This info is shown if you enter a not correct access code Try again H5 A1 Calibration of supervised outputs The access code was Code for level 3A Sensitive fault detection mode correct 4 digits Service mode for COM loop Press lt or scroll to the Display current consumption in control unit wanted menu and press Display current consumption on COM loop maT Display statistics for communication Activate address setting mode for DU Service mode for BS4 loop Display current consumption on BS4 loop H8 S1 Disconnect loop zone line input The access code was Code for level 3A S2 Re connect loop zone line input correct 4 digits S3 Acknowledge SERVICE signal Press lt or scroll to the S4 Clear weekly average wanted menu and press S5 Test of alarm devices Mm S6 Safe shut down of control unit S7 Activate address in alarm mode S8 Synchronize the control units S9 Change code for service maintenance 10 Change code for PC communication 129 Panas
153. teries are placed outside the control unit In the New Zealand convention only Battery voltage is below 24 4 V This check is done every 14 minute every 30 second in the New Zealand convention i e after correcting the fault it might take up to 14 min 30 seconds until it disappears from the fault list 512 G3 e Battery voltage is below 18 9 V e Batteries 2 x 12 V are missing or not connected correctly Fuse F2 on the Main board 5010 is blown Other battery fuse is blown This check is done every 14 minute but when the fault is generated the check is done every 30 sec Fuse T6 3A H 250V 5x20 mm ceramic The charging function in the external power supply 3366 connected on the COM loop is not OK The p c b has to be replaced Batteries 2 x 12 V are missing or not connected correctly Check the output unit battery connections fuse F3 on the power supply board in the output unit 59 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x FAULTS Charger Control wni xx The battery charging function is not OK The main board 5010 may have to be replaced The fault is to be found in the external power supply equipment which has a charging fault output connected to a programmable input in control unit no xx TAUTE ClBieoaling OUTE UNIE ESSES The charging function in the external power supply unit is not OK
154. th software EBL512 G3 United version 2 7 x in a TLON Network i e a mixed system EBL512 G3 United version 2 7 x can only be used in a mixed system 12 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 3 Overview 3 1 The EBL512 G3 system EBL512 G3 is a microprocessor controlled intelligent fire alarm system intended for analog addressable smoke detectors as well as conventional detectors and manual call points Programmable control outputs and output units are available Up to 508 addresses can be connected to each control unit c i e EBL512 G3 is available in several types versions and configurations It can be connected to a TLON network i e in a system with up to 30 control units Each control unit has access to all information Product type no 5000 EBL512 G3 c i e With or without a printer With front and display 5001 EBL512 G3 c i e Without front display and printer No door EBL512 G3 is designed according to the European standard EN54 part 2 and 4 The Swedish front conforms to SS3654 3 1 1 Printer The control unit EBL512 G3 type 5000 can be delivered with a printer PRN included in the article number or without a printer In Ext Fire Brigade Panel 1826 it is possible to mount an optional Printer 1835 3 1 2 Expansion boards In the control unit c i e it is possible to mount up to six expansion boards
155. the power is turned on and the TLON network is running the SSD download can take place The PC has to be connected to the D connector J1 in an EBL512 control unit Start Win512 version 2 7 x Log on to the control unit access code for level 3B shall be entered via the PC Win512 version 2 7 x In Win512 version 2 7 x menu Tools Download SSD you select the unit s to which the SSD shall be downloaded Check All Loop Units In the Win512 version 2 7 x COM loop icon pop up menu select Check All Loop Units This function can be used after or before the download of SSD The function is as follows The control unit will find all units that are connected on the COM loop The addresses 0 127 will be reported to Win512 For all 430x 33xx units and some of the other units the type of unit will also be reported All differences compared to the Win512 SSD will be listed in the Win512 log view and can be saved and or printed out NOTE During this check the COM loop will be disconnected disabled and no alarms or faults can be activated Disconnected COM loop is indicated by the LED Disablements L10 Single Control Unit Start the downloading from Win512 version 2 7 x A text message will be shown in the control unit display Downloading SSD When the download is completed the control unit will restart see chapter Restart page 94 After the restart another text message will be shown in the display
156. tion Units and Presentation Units Display Units 38 Panasonic Eco Solutions Nordic AB MEW01473 15 Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Alarm types 15 1 In case of a fire analog detectors sensors conventional smoke and or heat detectors manual call points and programmable inputs can activate fire alarm If somebody illegally breaks into a key cabinet this will also activate a fire alarm i e a key cabinet alarm A fire alarm could be an Alert Annunciation alarm i e the activation of the routing equipment fire brigade tx is delayed during an acknowledgement time and an investigation time respectively The analog detectors can also activate two other types of alarm i e Pre warning and Heavy smoke alarm Heavy heat alarm Two unit dependent addressable alarm points normally only smoke detectors and 2 zone dependent zones can activate a Co incidence alarm Quiet alarm is normally used for fan control only and will not activate fire alarm In the Australian convention only an Alarm Acknowledgement Facility function can be used During the Acknowledgement Period and the Investigation Period respectively there will only be an indication in the c i e display NOTE Special hardware is required Acknowledged and Isolated alarm is a fire alarm function only used in New Zealand Regarding the different alarm types etc see the following chapters NOTE In th
157. umption in unit Display current consumption on COM loop Display statistics for communication Activate address setting mode for DU Service mode for BS4 loop Display current consumption on BS4 loop Write control unit number and loop number and press n lt li g If the control unit don t exist or don t answer 136 Panasonic Eco Solutions Nordic AB MEWO01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Number of pollings nnnnnnn Note The values are not Parity fault 000000 00 0 live updated Number of bit faults 000000 00 0 No answer 000000 00 0 Bit length fault 000000 00 0 A6 Display statistics for communication Scroll to another menu or press ESC 137 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 28 8 Activate address setting mode for DU H5 A7 This function can be used by commissioning service engineer to activate the address setting mode in the following Display Units connected to the c i e e Ext Presentation unit 1728 e Alert Annunciation units 1735 amp 1736 e Ext FBPs 1826 amp 1828 A specific unit or all units connected to one c i e can be activated for address setting NOTE The units have to be in operation and in quiescent condition i e the units have to have an address already Text in display Comments Menu According to chapter Access code fo
158. ut S0 S3 a i Disable ooo output 0 Write the data for the Depending on the press lt output respectively selected type the Press lt to accept following will be Disable CU Ko S 0 LED Fault Disablements shown press General disablements Disable CU Jo R 0 L10 will light up press lt Disable control unit fo exp board 0 output 0 Disable output type 361 3364 Disable another output or S press ESC Scroll to R another menu or press Expansion board ESC 107 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 25 4 Re enable zone H2 B4 Disabled zones are listed in menu H4 U1 from which it is also possible to get a print out Re enabling via this menu has higher priority than automatic re enabling When all zones have been re enabled The LED Fault Disablements General disablements L10 will be turned OFF if there are no other disablements in the system NOTE It is not possible to collectively re enable a number of alarm points zone address that are individually disabled via menu H2 B2 Menu According to chapter Access see page 98 Scroll to menu H2 H2 Disable or re enable Disable zone Disable zone address Disable output Re enable zone Re enable zone address Re enable output Disable re enable output type Disable re enable alarm devices Disable re enable routing
159. ut down of control unit it oe Shut down control unit do Write control unit number Yes and press Y for Yes Tf not a fault FAULT Read write site data SSW CU xx might be generated when you power up the control unit again 154 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Ready for shut down break the power The SSW is now saved and Automatic restart within xxx seconds the Main board and MMI board CPUs are at rest xxx will start at 300 seconds and countdown to 000 before You can now power off the the control unit will restart automatically control unit If not the control unit will restart automatically after 5 minutes 300 seconds Power off Power on FAULT Restart control unit nn code xx After a restart power on or address yyyyyyyyyy see page 94 there will after 5 min yyyy mm dd hh mm always be a fault generated The code will be 00 and the address 0 This fault has to be acknowledged see chapter FAULT Acknowledge H6 page 142 NOTE Before the very first safe shut down the Flash ROM is empty Then every time safe shut down is performed the valid data will be saved in the Flash ROM i e any old data will be overwritten When the c i e is powered up the data stored in the Flash ROM will be used WARNING If safe shut down is not performed just before a c i e power down then by power on the
160. utions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Check the charging voltage over the battery respectively 13 5 13 8 depending on the actual charging step Check the voltage over a disconnected battery fully charged gt 13 V In the New Zealand convention only The battery charging is turned off 60 minutes every 24 hour A battery voltage lt 24 4 V during these 60 minutes will generate a fault If a fault is generated it will automatically be Serviced after these 60 minutes The battery should normally be replaced NOTE The battery check is performed every 4 hour i e it can take up to 12 hours until the fault status will be corrected System voltage lt 21 V DC in control unit no xx Check the power supply rectifier 1537 5037 output voltage which shall be 24 V DC Replace 1537 5037 if required System voltage lt 21 V DC in the external power supply unit 3366 Check the power supply rectifier 1537 output voltage which shall be 24 V DC Replace 1537 if required The delay time 1 300 minutes is programmable via Win512 version 2 7 x Max 30 min according to the EN54 2 standard Default value depending on convention 512 The fault is activated 1 300 minutes after Loss of mains i e no 230 V AC Blown mains fuse Blown fuse F1 on Charger board 1557 1657 Battery charging has been turned off for some security reason e g too high current con
161. utside switch NOTE The functions in this chapter are valid for the New Zealand convention only The New Zealand FB Silence switch is also called the outside switch since it is placed outside the c i e The outside switch is a key switch connected to a programmable input with the trigger condition New Zealand FB Silence switch The outside switch can be in two states The outside switch is turned ON i e from not activated to activated state e All programmable outputs of type Alarm devices are disabled i e they cannot be activated The inside switch see above has no function e The c i e built in buzzer is silenced e A fault is generated FAULT FB Silence switch active The outside switch is turned OFF i e from activated to not activated state e FAULT FB Silence switch active will be Serviced e Any fire alarm ALARM and acknowledged alarm ACKNOWLEDGED will automatically be disabled isolated Le it has to be re enabled via menu H2 B5 Indicated by LED General disablements on the c i e front e Any fire alarm ALARM and acknowledged alarm ACKNOWLEDGED will automatically change the state to Isolated alarm see below and in the fire alarm list presented in the display ALARM or ACKNOWLEDGED will be replaced with ISOLATED An example Since this fault is always latched it has to be acknowledged via menu H6 30 Panasonic Eco Solution
162. version 2 7 x 28 5 Display current consumption in unit H5 A4 NOTE The following is valid for an EBL512 G3 control unit If the control unit number CU XX is valid for an EBL512 control unit some information is not shown Control unit The total current consumption including the charging current at 24V for the selected control unit c 1 e when it is connected to the mains 230 V AC i e this function is not working by battery backup Charging The battery charging current for the selected control unit c i e Also the battery temperature is shown Action Text in display Comments Menu According to chapter Access code for service and maintenance H5 and H8 see page 129 A1 Calibration of supervised outputs A2 Sensitive fault detection mode Service mode for COM loop Display current consumption in unit Display current consumption on COM loop Display statistics for communication ii Activate address setting mode for DU Service mode for BS4 loop A9 Display current consumption on BS4 loop Scroll to menu A4 ADI E Waele dccTaimere alsielanlelielamiamelalit Select control unit fo press lt Write control unit number and press lt l I No reply from control unit If the control unit don t exist or don t answer Current consumption in control unit 00 From rectifier xxxx mA Charging xxxx mA battery temperature xx C Low capacity voltage diff xxxxx mV 2 or ESC A4
163. vy smoke heat_alarm is to confirm heavy or increasing smoke heat and can be used for special actions e g activation of smoke ventilation etc The following happens in case of a heavy smoke heat alarm e Outputs programmed for heavy smoke heat alarm are activated e Each heavy smoke heat alarm is presented with a title i e Heavy smoke or Heavy heat will be added to the normal fire alarm information LED Fault Disablements General disablements L10 is indicating that one or more zones alarm points are isolated disabled 23 See EBL512 G3 Planning Instructions General heavy smoke heat alarm and individual alarm points zones 44 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x First alarm 002 03 Alarm number 1 of 1 Heavy smoke Zone Address 002 03 svo User definable alarm text for 002 03 The printer if available will print each heavy smoke heat alarm e g Heavy Smoke Zone 002 Address 03 SMOKE YYYY MM DD hh mm User definable alarm text if progr Heavy smoke heat alarm will be reset when the fire alarm respectively is reset see chapter Alarm reset page 50 15 4 Alert Annunciation alarm AA alarm When the AA function is enabled indicated by the LED Routing equipment Fire brigade tx delay L14 the indications print outs actions etc are the same as for a no
164. x Select control unit o All Write the CU number or press P and select All Blank space all CUs Press Disable or Re enable Escape menu DIRELG RERE Disable or Re Select control unit o All Disable or Re enable enable another output type Blank space control unit the procedure is similar for all types or press ESC Scroll to Escape another menu or press menu ESC NOTE When the output type contr exting vent is selected outputs of these three types will be disabled all at the same time This can be done for one or more Selected control units or All control units To indicate such a disablement the output trigger conditions Control Disabled Control Unit xx and General Control Disabled respectively can be used 5l NOTE Outputs disabled for a specific control unit e g CU 03 can not be collectively re enabled via all CUs You have to re enable the outputs for the specific control unit s e g CU 03 113 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 25 8 Disable re enable alarm devices H2 B8 Outputs programmed as type alarm device sounder can be disabled all at the same time Disabled alarm devices means that even if the control expression trigger condition for the output respectively is fulfilled true the output will not be activated The outputs in one or more control units can b
165. xample EBL512 G3 Control Unit 00 Panasonic Electric Works Nordic AB 2011 02 02 10 58 24 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 7 Access levels EBL512 G3 has different access levels 1 4 for different kind of users Access levels 2 and 3 are divided in sub levels A B Access Access code Required action Users Action level password 1 N A Anybody Scroll browse Door closed through the queued alarms 2A N A Fire brigade key Fire brigade Fire alarm handling personnel 2B PERE Fire brigade key Building Installation handling access code for level occupier daily duties e g 2B or 3A installation monthly tests dis owner ablements etc 3A nae Fire brigade key Service Service access code for level maintenance maintenance 3A personnel commissioning etc 3B webs PC Win program Service Service connected PC maintenance maintenance access code for level commissioning commissioning etc 3B engineer via Win512 version 2 1 x 4 wees PC Win program Manufacturer Changing factory connected PC settings access code for level 3B and level 4 The access codes can be changed To change a code you have to use the valid code or use a code for a higher access level Retailers are informed regarding the default access code respectively 8 The c i e door is closed bu
166. xt in display Comments Menu According to chapter Access see page 98 Scroll to menu H9 H9 Interlocking outputs and inputs ta C2 Activate interlocking output C3 Reset interlocking output C4 Disable interlocking output C5 Re enable interlocking output Scroll to menu C1 C1 Activated interlocking outputs inputs a Interlocking area AAA point PP output active Menu C1 is a list in User definable text message if progr which you can scroll Depending on da hike activated output and or YYyy mMM ae soul II I RII Mele AOSD A Ate Set PAIN IO IIIS le Me Press ESC to menu input the following Interlocking area AAA point PP input output active C1 will be shown User definable text message if progr yyyy mm dd hh mm Interlocking area AAA point PP input active User definable text message if progr yyyy mm dd hh mm C1 Activated interlocking outputs inputs Scroll to another menu or press ESC 162 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x 32 2 Activate interlocking output H9 C2 The output in each interlocking combination area point can be manually activated via this menu The corresponding interlocking input will be monitored in the same way as if the output was activated by its control expression Reset has to be performed via menu H9 C3 er Access see page 98 a C2 Activate interlocking output
167. xx SCL ii lt gt SCI in This fault is indicating a cut off break on COM loop x or the COM loop voltage is too low at the end of the loop i e lt 12 V DC SCI n lt gt SCI n describes between which Short Circuit Isolators 4313 the cut off is located n A B 0 1 2 3 4 5 6 amp 7 A amp Bis the built in isolator in the EBL512 G3 A direction and B direction respectively i e if no SCI is used the information will always be SCI A lt gt SCI B If only one SCI is used i e 4313 no 0 the information will be SCI A lt gt SCI 0 or SCI O lt gt SCI B and so on If it is a single break cut off on the loop there will be no other fault messages If there are several breaks on the loop the message shows the last isolator before the break in the A direction incl the following isolator There will also be a FAULT No reply message for each unit that EBL512 G3 cannot find and FAULT Multiple faults NOTE Each 10 minute a new attempt is made to communicate in one direction only When all breaks are repaired corrected the communication automatically returns to communicate in one direction only FAULT Display unit xxxxxx Display unit out of work Fault in the display unit EEPROM site specific data Download the data again or change the EEPROM and download the data again FAULT Double addresses techn no XXXXXX Two or more units connected to a BS4 loop 1584 board have been
168. ystem EBL512 G3 United version 2 7 x Yb Fire L DO L2 4 Extinguishing lt P1 Silence L3 gt Ventilation buzzer am lt L4 a ee piece Silence alarm devices P GSS lt L6 See P4 P7 P8 Alarms queued Panasonic L7 L8 gt Systemes Testmode HER L9 L10 gt General fault i General disablements ze m zw L11 L12 gt of naman Of reve 4 5 L 6 C7 jC A L13 L14 S beL _o esc J Figure 2 The EBL512 G3 front with display The Fire Brigade Panel FBP is the upper part and the Control Panel CP is the lower part The look might vary according depending on language country etc A front with texts in English is shown in the figure See also chapter LED indicators and push _ buttons page 18 The fire brigade personnel use the FBP to see which alarm point zone s having activated fire alarm and to take required operational control of the system In the graphical display the information in the upper part is depending on how many alarm points zones having generated fire alarm In the middle part a user definable text message alarm text is shown for each alarm point zone in alarm if programmed The CP is to communicate with the system i e for commissioning monthly tests maintenance etc Access codes for different access levels are required A keypad is used to get access to the system a menu tree with main and sub menus and fo
169. yyyy hh mm Quiet alarm One or more smoke detectors via Win512 version 2 7 x programmed for Quiet alarm have passed the fire alarm level Quiet alarm is used for fan control stop or start is depending on the type of fan Quiet alarm is normally used in conjunction with one I O Matrix board 4582 one application board for fan control and one I O unit for fan control 3361 for control of each fan Indications and actions Detector LEDs are turned on i e also a connected ext LED LEDs Fire L1 are blinking 0 4 0 4 sec the buzzer sounds 0 8 5 sec and there is a Quiet alarm presentation incl a title Quiet alarm in the display 25 The AAF Control is today available on the Australian market only 26 The Fan control panel 4593 can be used for control of up to eight fans 48 Panasonic Eco Solutions Nordic AB MEW01473 Rev Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Quiet alarm Zone Address T 23 45 SMOKE User definable alarm text for 123 45 Programmable outputs for quiet alarm e g 3361 outputs controlling supply air fans and standard fans i e any output with a control expression containing the trigger conditions Quiet Alarm Zone or Quiet Alarm Zone Address Quiet Alarms are automatically reset see page 53 49 Panasonic Eco Solutions Nordic AB MEWO01473 16 Operating Instructions Fire alarm system EBL512 G3 United version 2 7 x Alarm reset