Home

Lataa käsikirja / asennusohje

image

Contents

1. 0 Temp Alert GSM SMS Air Conditioner IR Controller for A C Management 22 Meeting Room Office ow i AIC Management AAY 2012 02 22 Thur 10 00 High Temp alarm Switch on the A C 4 2012 02 22 Thur 10 00 Class Room Hospital AIC us gt Management 2012 02 22 Thur 10 00 pana anee DEEA Swithced ON A C Switched OFF A C Set as 16C KING PIGEON lt lt www GSM M2M com lt me gt GSM Temperature Alarm p E E De GSM SMS Air Conditioner IR Controller Table of Contents 1 Brief Introduction 3 2 Safety Directions 3 3 Standard Packing List 4 4 Mainly FeatureS 4 5 Physical Layout and Installation Diagram 5 5 1 Control Unit physical layout 5 5 2 Interface instruction for installation 6 5 3 Recommen
2. E g the country code is 0086 or 86 The user cell phone number is 13600000000 and has been assigned as a SMS Alert number the simcard number in the panel is 13512345678 When you setup the number as the authorized number please setup as 008613600000000 or 86136000000000 Not 13600000000 8 Ifthe password is correct but the the command is incorrect the RTU5014 will return SMS Format Error Please check Caps Lock in Command So please check the Command or add the country code before the telephone number or check the input is in ENGLISH INPUT METHOD and CAPS LOCK If password incorrect then will not any response SMS 9 Once the GSM Unit received the SMS Command will return SMS to confirmation if no SMS return please check your command or resend again 10 The SMS commands that you will certainly use in the GSM units are the following 7 1 Setup New Password pwd is the GSM Unit password default is 1234 P is the identification character of this command if successful the unit will return Set Success The password is 4digits Example The original password is 1234 you want change it to 6666 then you can send the command below 1234P6666 7 2 Setup Authorized number The GSM Unit supports upto 6 authorized phone number each number can be setup as different rights to receive alarm message Serial Number 1 6 A is the identification ch
3. B Time command then the existing SMS text message will not be changed After the GSM Unit received will return Time SMSTextmessage Page 12 of 18 King Pigeon Hi Tech Co Ltd Page 120f18 Ver 1 0 File No RTU501410 lt m GSM Temperature Alarm if Pt GSM SMS Air Conditioner IR Controller Inquiry Settings The user can send SMS Command to inquiry the settings the command is After the GSM unit received will return Time SMSTextmessage I ips 1 This function only valid when the air conditioner was switched on 2 Before change to Enable this function please connect the PIR Motion detector firstly 7 5 Setup Automatically Report Time The user can setup interval time to report the GSM Unit current status to the first authorized number The SMS command is D D is the identification character of this command 0 99 unit is hour stands for how many hours does the GSM Unit should report its current status to the first authorized number Default is 0 stands for disable this function 7 6 External AC Power Status Monitoring The GSM Unit will automatically monitoring the external AC power while AC power goes off will send AC Power Goes OFF to the first authorized number immediately and while the external AC power goes on will send AC Power Goes ON to the first authorized number immediately When the backup battery voltage lower than 3 6V will send the SMS Backup Battery low voltage to the f
4. Programmable by SMS Commands with password protection VV V WV Based on GSM Network applied to many applications 5 Physical Layout and Installation Diagram 5 1 Control Unit physical layout IR Transmitter GSM Battery GSM SMS Air Conditioner IR Controller RTUSO4 Page 5 of 18 King Pigeon Hi Tech Co Ltd Page5of18 Ver 1 0 File No RTU501410 KI PIGEON lt ma o GSM Temperature Alarm w A GSM SMS Air Conditioner IR Controller LED Indicator Instruction POWER External DC Power status LED indicator IR IR transmission indicator when transmission IR will on otherwise will off GSM GSM Module Status indicator registering GSM Network flicks quickly registered successful flicks slow No GSM Signal will be off Battery Charging battery will on otherwise will off RUN GSM Unit Status ON stands for switched on off stands for switched off Low Volt Low voltage indicator will on when backup battery low voltage till recovery A C ON Air Conditioner ON Matching IR Coding of the air conditioner indicator only in matching code status will MATCH on otherwise will off The air conditioner status indicators Will on if the related function is on Otherwise Others will off 5 2 Interface Instructions for installation At the backside of the panel please use the tool to remove the screw and you can see the below Connector Interface DC9 18V positive input 1A
5. and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registered electrician be sought before any Installation work commences King Pigeon Hi Tech Co Ltd its employees and distributors accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook King Pigeon Hi Tech Co Ltd its employees and distributors accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook Page 2 of 18 King Pigeon Hi Tech Co Ltd Page2of18 Ver1 0 File No RTU501410 lt me gt GSM Temperature Alarm v a GSM SMS Air Conditioner IR Controller 1 Brief introduction The GSM SMS Air Conditioner IR Controller is special for operating air conditioner by SMS commands monitoring onsite temperature Also the GSM SMS Air Conditioner IR Controller can be used for automatically turn on Heating function when low temperature alarm occurrence or turn on COLD function when high temperature alarm occurrence or automatically turn OFF the Air Conditioner while nobody onsite The GSM SMS Air Conditioner IR Controller can be used for temperature monitoring Class Room Public Room Waiting Room Hospital Stations Fresh Food Warehouse Office Meeting Room Laboratory Library and anywhere that need intelligent manage air conditioner or monitoring tempera
6. for power on the GSM Unit DC9 18V negative input 1A for power on the GSM Unit DC9 18V Page 6 of 18 King Pigeon Hi Tech Co Ltd Page6of18 Ver1 0 File No RTU501410 a GSM Temperature Alarm p p a A Gsm sms air conditioner IR Controller DIN Digital Input Dry Contact for human movement detector Digital Input GND Digital GND 3 3V 3 3V Direct Current Output Positive for 3 3V Temperature Sensor Temp Input Temp Temperature Sensor input DS18B20 sensor only GND Temperature Sensor input GND 5 3 Recommend Detectors Recommend Detectors Name Descriptions Photo PIR 01 Wired For Human movement detection in indoor wall installtion Suitable wall installation type PIR Motion DC12V Powered up Sensor Output Type NC Default is NC Gross Weight 0 16Kg External Size 10CM 6 5CM 5 5CM a CPIR 03 Wired For Human movement detection in indoor Ceiling PIR Suitable Ceiling installation type Motion Sensor DC9 16V Powered up Output Type NC Default is NC Gross Weight 0 18Kg External Size 11CM 11CM 4 0CM DS18B20 Replace the inbuilt temperature sensor can be extend the Temperature temperature sensor outside the housing Sensor Measurement range of 55 C to 125 C and is accurate to _0 5_C over the range of 10 to 85 C Wire length is 100cm 6 Matching Air Conditioner Operation 6 1 Initialize t
7. for the applications that required keep the environment temperature in the expected range Like fresh food warehouse public room hospital and so on Please see below to setup them High Temperature Alarm switch on the air conditioner SMS Command After the GSM unit received will return H ENS Groupcode HTON HTON is the identification character of this command Groupcode AA BB CC DD or 99 a quickly control Combination command see 8 4 Quickly Control Combination Commands if the Group 99 stands for disable this function Default is disabled Page 11 of 18 King Pigeon Hi Tech Co Ltd Page 110f18 Ver 1 0 File No RTU501410 lt m gt 6SM Temperature Alarm v Pt GSM SMS Air Conditioner IR Controller When switched on the air conditioner by the condition of this command will send SMS to authorized numbers the SMS Content is High Temp alarm Switch on the A C Low Temperature Alarm switch on the air conditioner SMS Command After the GSM unit received will return H ENS Groupcode LTON LTON is the identification character of this command AA BB CC DD or 99 a quickly control Combination command see 8 4 Quickly Control Combination Commands if the Group 99 stands for disable this function Default is disabled When switched on the air conditioner by the condition of this command will send SMS to authorized numbers the SMS Content is Low Temp alarm Switch ON the A C Inqui
8. is Auto Mode COLD pwd COOL Mode is Cool Heat pwd HEAT Mode is Heat Dry pwd DRY Mode is Dry Wind pwd WIND Mode is WIND WIND Mode Low Wind pwd LWIND Low wind Middle Wind pwd MWIND Middle wind High Wind pwd HWIND High wind Auto Wind pwd AWIND Auto wind Temperature Change pwd T Value Set as xx 1234T16 to change the Page 17 of 18 King Pigeon Hi Tech Co Ltd Page 170f 18 Ver 1 0 File No RTU501410 a _ GSM Temperature Alarm O ESM SMS air conditioner in controtter Mode Temperature Degree C temperature to 16degree Table3 Quickly Control Combination Command Definition After setup the GSM Unit please write down the definition it is very useful for saving your time for you review After installed successful then tear off this for review in further eee eee eee ee eee eee err e eee eee eer eee eee errr reece ere err erreur ec e ere erreur rece rere reece errr erreur cece eee errr reer reece reece erry Quickly Control Combination Command Definition Serial No SMS Command Combination Command Definition 1 pwd AA 2 pwd BB 3 pwd CC 4 pwd DD High Temperature Threshold Value C Alarm will Switch ON Air Conditoner Yes No Low Temperature Threshold Value C Alarm will Switch ON Air Conditoner Yes No Air Conditioner Brand Menu Code Table 4 Installation Schedule Before setup the GSM Unit please write down the installation plan f
9. A C Brand Combination Menu Code Menu Code A C Brand A C Type Qty A C Brand A C Brand A C Type Qty SUNBURG 4 AKIRA 2 Daotian 4 KLIMATAIR 4 a TOYO 4 oe LOREN SEBO 3 GLEE 1 NIKKO 2 Page 16 of 18 King Pigeon Hi Tech Co Ltd Page 16 0f 18 Ver 1 0 File No RTU501410 KING PIGEON ot ie GSM Temperature Alarm GSM SMS Air Conditioner IR Controller operation please see below mentioned Huawei 1 ELCO 1 KT02_D001 1 ELECTER 6 KT02_D002 1 FEDDERS 1 KTY001 1 SPEED 1 KTY002 1 TADIAIR 4 KTY003 1 TADIRAN 9 KTY004 1 51 55 100 types of Other Small Brands KTY005 1 60 64 107 types of Other Small brands ALPIN 4 AMCOR 7 AMICO 1 BOERKA 1 CONSUL 1 57 JOHNSO 1 NISO 1 SOGO 1 UNI AIR 2 NORCA 1 ips A C Type Qty Stands for how many types air conditioners under this Brand and each type with unique IR Code E g LG has 10 types means it has 10 groups IR code so while match the LG Air Conditioner must setup the menu code 9 firstly and then continue tol match the LG IR Code Groups from its first Group till it matched The matching Table 2 Operation SMS Command Table Operation SMS Command Table Mode Function SMS Command Return SMS SMS Example Status Mode ON pwd ON A C ON 12340N 1234 is password OFF pwd OFF A C OFF 1234O0FF 1234 is password Function AUTO pwd AUTO Mode
10. Executed Definition the Combination Command The quickly control Combination command can be defined by user self The commands are below GroupCode AA BB CC DD stands for the 1st group Combination command 2nd group Combination command 3rd group Combination command 4th group Combination command ON Stands for Status Mode command ON Cannot be OFF Command1 Stands for Function Mode Command AUTO COOL HEAT DRY WIND Command2 Stands for Wind Mode command LWIND MWIND HWIND AWIND Commands3 Stands for Change Temperature command Txx the xx is the value of the temperature T ips The Command1 Command3 cannot be blank these commands are incorrect wd Groupcode ON Command1 Command2 wd Groupcode ON Command1 Command3 A wd Groupcode ON Command2 Command3 A Example Setup the first group quickly control Combination command as switch on the air conditioner clod mode middle wind and temperature is 20degree If the password is 1234 then please send the SMS Command Page 14 of 18 King Pigeon Hi Tech Co Ltd Page 140f18 Ver 1 0 File No RTU501410 lt m GSM Temperature Alarm lt m p a GSM SMS Air Conditioner IR Controller 12344AA HON COOL MWIND T20 to the GSM Unit after the GSM unit received it will return SMS AA ON COOL MWIND T20 After you setup it then when you send 1234AA to the GSM unit it will carry out these commands o
11. aracter of this command Function 1 Code 1 2 3 It is for alarm receiving attribute setting 1 stands for when alarm occurrence the GSM unit will dial as well as send SMS to this number 2 stands for when alarm occurrence the GSM unit only send alarm SMS to this number doesn t dial 3 stands for when alarm occurrence the GSM unit only dial this number doesn t sends SMS Telephone Number authorized number must include country code max 18 characters Page 9 of 18 King Pigeon Hi Tech Co Ltd Page9of18 Ver 1 0 File No RTU501410 KING PIGEON lt m o GSM Temperature Alarm w A GSM SMS Air Conditioner IR Controller E g if you want to setup 13512345678 as the third authorized number and the password is 1234 country code is 0086 when alarm occurrence this number can receive both SMS and incoming from the GSM Unit Then you can send 1234 3A1 008613512345678 to the GSM Unit Will return Tell Empty Tel2 Empty Tel3 008613512345678 1 Tel4 Empty Tel5 Empty Tel6 Empty Inquiry the Authorized number After received this command the GSM Unit will return the SMS as abovementioned E g If you want to know the authorized number list and the password is 1234 then you can send 1234A to check it Remove the Authorized Number Please overwrite it with another new number or removed it by this SMS Command Tips If setup the authorized number as receive dial from the GSM unit th
12. d Detectors 7 6 Matching Air Conditioner Operation 7 6 1 Initialize the GSM unit 7 6 2 Matching the GSM Unit and Air Conditioner 7 7 UU see lt ee esse ese c cece cece cess SoS Se Se SS SSS SS SSE SS Se SSIS SS SS SE ESSER 8 7 1 Setup New Password 9 7 2 Setup Authorized number 9 7 3 Setup Temperature High Low threshold Alarm Value 10 7 4 Setup Nobody Onsite Automatically Switch OFF the Air Conditioner 12 7 5 Setup Automatically Report TiMe 13 7 6 External AC Power Status Monitoring 13 8 Operation Instructions 13 8 1 Inquiry the IMEI Code and firmwa
13. e GSM unit will dial them one by one once or till answered the call 7 3 Setup Temperature High Low threshold Alarm Value The GSM Unit inbuilt a temperature sensor already measures temperatures from 55 C to 125 C 67 F to 257 F 0 5 C accuracy from 10 C to 85 C but the temperature accuracy will be effected by the GSM Unit if the user want to extend it to other place or want to get accurate temperature the user can extend the DS18B20 Temperature Sensor The GSM Unit reserved 3 3V power for this DS18B20 Temperature Sensor to save the wiring cost The user can setup temperature high and low threshold value when the onsite temperature high or low than the threshold value will send SMS or dial to the authorized numbers Please see below to setup the threshold value If the temperature unit is Celsius the command is For setup the High threshold value For setup the Low threshold value After the GSM Unit received these commands will return H ENS or L ENS Page 10 of 18 King Pigeon Hi Tech Co Ltd Page 10o0f18 Ver 1 0 File No RTU501410 lt ma GSM Temperature Alarm w A GSM SMS Air Conditioner IR Controller H H is the identification character of this command Stands for the high temperature value 99 999 999 stands for disable this function Default when the temperature higher than this value will send SMS and dial to the authorized numbers The SMS C
14. e the table so send 1 234MENU 9 to the GSM unit to match them The SMS command must be CAPTIAL LETTER 6 When the GSM Unit received this SMS will alert by two quickly didi sounds 7 Put the GSM Unit IR Transmitter towards to the air conditioner and away the air conditioner less than 2meters 8 Press the Learn Button again the MATCH LED will on and the GSM Unit will send IR signal of the ON function to the Air Conditioner to match it the A C ON LED will on and IR LED will be on while every IR transmission 9 After the air conditioner received the IR signal it will response to ON function firstly and then will automatically match the Fan Temperature plus Temperature Reduce and OFF code after matched the OFF code the MATCH LED will be off and the air conditioner will be switched off Restart the GSM unit to save this code the matching code operation finished 10 If the air conditioner received the IR Signal but no response the ON function means this IR Code unmatched to the air conditioner please press the Learn button once to stop the matching and press it again to let it match the next IR Code of this Air Conditioner Brand till it successful 11 Test how to operate the air conditioner via GSM SMS Commands please see chapter 8 7 Programming Notice 1 The default Password is 1234 2 Before powered on the GSM Unit please insert the SIMCard inside after power on the unit the buzzer will a
15. he GSM unit The GSM Unit should be initialized before programming and operating it please follow below steps to initialize it After initialized the parameters will set as factory default Switch off the GSM Unit and insert the SIMCard firstly connect the battery Press the RESET button 1 2 3 Switch the Switch to ON side to powered on the GSM Unit holding 5seconds after heard 1Second Di sound alert then loose the RESET Button 4 Restart the GSM unit then will enter to work mode 6 2 Matching the GSM Unit and Air Conditioner After initialized the GSM Unit please follow below steps to match the GSM SMS Air Conditioner IR Page 7 of 18 King Pigeon Hi Tech Co Ltd Page 7of18 Ver1 0 File No RTU501410 lt me gt GSM Temperature Alarm v a GSM SMS Air Conditioner IR Controller Controller to compatible with the air conditioner 1 Find out the air conditioner menu code see Affix Table 1 Connect the Air Conditioner to AC power and power on it 3 Switch off the GSM Unit firstly and press the Learn button and hold it the LEARN LED will be on Switch on the GSM unit it will make two didi short sounds stands for the GSM unit registering the GSM Network after registered the GSM Network it will alert by two quickly sounds 5 Loose the Learn Button and edit the SMS content jpwd MENU Menucode then send to the GSM Unit E g for LG Air Conditioner the default password is 1234 and LG Menu code is 9 Se
16. irst authorized number immediately 8 Operation Instructions 8 1 Inquiry the IMEI Code and firmware version The user can inquiry the IMEI Code and the firmware version by SMS command the SMS Command is After the GSM Unit received will return IMEI Code XXXXXXXXXXXXX Version V 8 2 Inquiry the GSM Unit current status The user can inquiry the GSM Unit current status by dial in the GSM unit through authorized numbers or send SMS command The SMS Command is Will return Page 13 of 18 King Pigeon Hi Tech Co Ltd Page 130f18 Ver 1 0 File No RTU501410 KING PIGEON _ GSM Temperature Alarm pe GSM SMS Air Conditioner IR Controller Actual temp is xx Degree C A C is XXX AC Power is ON OFF GSM Signal is xxx I ips The GSM Signal value from 15 30 stands for the gsm signal is normally 8 3 Remote Operate the Air Conditioner by SMS Commands The user can send SMS command to control the Air Conditioner the SMS command list see Affix Table 2 8 4 Quickly Control Combination Commands The GSM Unit supports 4 Group quickly control Combination commands in order to quickly and easily to operate the air conditioner no need to send separate command one by one Quickly Control Combination Commands Serial No SMS Command Return SMS Example 1 pwd AA Executed 1234AA 1234 is the password 2 pwd BB Executed 3 pwd CC Executed 4 pwd DD
17. irstly it is very useful for saving test and installation time After installed successful then tear off this Schedule for review in further eee eee eee ee eee eee eer eee eee rere eee reece reer ee re err err er eee eee erreur reer r reer ere errr creer ee creer ere err e reer rere reece erry your Installation Schedule SIMCard Number in the GSM Unit Installation Address Alert Method Authorized Type Serial Number User Name Phone Number SMS amp Call SMS Call 1 2 3 4 5 6 Notice Please mark V if for enable and X for disable The End Any questions please help to contact us feel free Http www GSM M2M com Page 18 of 18 King Pigeon Hi Tech Co Ltd Page 180f18 Ver 1 0 File No RTU501410
18. lert by 1 long Di sound to alert if the MCU can not communicate to the GSM Module or not find out the SIMCard or Simcard installed failure or no gsm signal the GSM Unit will restart automatically 3 All the settings are through SMS commands please edit the below SMS commands in your cell phone then send to the GSM unit The unit cannot support PIN Code Protected SIMCard 4 You can program the GSM unit with SMS commands using your phone It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted in it we also use a Password that makes it impossible for anybody who doesn t know it to access the system by chance 5 Remember that commands must be CAPITAL LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other character Page 8 of 18 King Pigeon Hi Tech Co Ltd Page 8of18 Ver1 0 File No RTU501410 lt m gt 6SM Temperature Alarm m Pt GSM SMS Air Conditioner IR Controller 6 The pwd in the commands is means the password when you use it please in stand of it by the digital number the capital letters PWD is the command letter use PWD directly 7 In some GSM operators they use different SMS parameter the units can t return the SMS confirmation in some gsm operators but it can performance the functions correctly Also you can try to add the country code before the number see the below settings For example
19. ne by one Delete the Quickly Control Combination Command The user can delete the Quickly Control Combination Commands by SMS Command the SMS Command format is below GroupCode AA BB CC DD stands for the 1st group Combination command 2nd group Combination command 3rd group Combination command 4th group Combination command Inquiry Settings The user can send SMS Command to inquiry the settings the command is After the GSM unit received will return Groupcode ON Command1 Command2 Command3 Example If password is 1234 then send 1234 MBBz to inquiry the 2nd Group Code settings 9 Technical specifications Rated Voltage 9 18V 1ADC Standby Consumption 30 35mA Not charging battery Working Consumption 400mA Working temperature 10 C 60 C Storage temperature 20 C 60 C Relative humidity 10 90 No condensation GSM frequency 900 1800MHz Default or 850 1900Mhz Optional SIM Card Supporting 3V SIM Card GSM Antenna 50 Q SMAAntenna interface Communication protocol GSM PHASE 2 2 include data service Digital Inputs 1 Dry Contact For human movement detection Temperature Sensor Inputs 1 inbuilt one DS18B20 can extend to external 55 C to 125 C 67 F to 257 F 0 5 C accuracy from 10 C to 85 C Backup Rechargeable Battery 3 7V 900mAH lithium batteries standby 8 hours External Size 150mmX92 6mmX30mm WXDXH Net Weight 0 50Kg 10 Warranty 1 Thi
20. ner management Vv Upto 6 authorized phone numbers each number can be used to receive call or SMS or both of call and SMS while alarm occurrence gt Intelligent professional air conditioner IR Encoder with compatible of almost all of the brand air conditioners See Air Conditioner Compatibility of RTU5014 gt One human movement detector if no body movement in the room then will turn off the air conditioner automatically It is useful for saving power consumption in public rooms Page 4 of 18 King Pigeon Hi Tech Co Ltd Page4of18 Ver 1 0 File No RTU501410 a gt GSM Temperature Alarm GSM SMS Air Conditioner IR Controller gt One Temperature Sensor inbuilt external connection is available measures temperatures from 55 C to 125 C 67 F to 257 F 0 5 C accuracy from 10 C to 85 C can setup high and low temperature alarm threshold value to alert the authorized users and automatically turn on the Air Conditioner to preset working mode gt Supports 4 quick operation combine commands the users can quickly operate the air conditioner by only one simply SMS command gt External AC Power monitoring AC On OFF will send SMS to authorized phone numbers Vv Timer Report Can setup every x hours automatically send its status Value to the authorized numbers Rechargeable Backup Battery inside can last 8hours Secure Using caller ID and password for identification unknown callers are ignored
21. ontent is HighTemp Alarm Actual temp is xx Degree C Air Conditioner AIC is xxx Status e g ON or OFF AC Power is ON OFF L Lis the identification character of this command Stands for the low temperature value 99 999 99 stands for disable this function Default when the temperature lower than this value will send SMS and dial to the authorized numbers The SMS Content is Low Temp Alarm Actual temp is xx Degree C A C is XXX AC Power is ON OFF ENS ENS is the identification character of this command Stands for the ensure time of temperature exceed the pre set value means when temperature exceed the value and last for how many seconds then consider is an alarm event 000 999 default is 300 seconds this parameter is in order to avoid false alarm Tips The temperature value can accept minus symbol and decimal like 20 degree then please input 20 for temperature value gt 0 then no need input e g 20 degree then please input 20 not 20 Also can setup as decimal e g 19 50 X Setup Air Conditioner response to the temperature High Low threshold value alarm The GSM Unit supports intelligent management temperature when the temperature higher than the threshold value it can automatically turn on the air conditioner to cold or other mode when the temperature lower than the threshold value it can automatically turn on the air conditioner to heat or other mode This is very useful
22. or might bring disturbance or danger Page 3 of 18 King Pigeon Hi Tech Co Ltd Page3of18 Ver1 0 File No RTU501410 lt mai gt GSM Temperature Alarm lt v a GSM SMS Air Conditioner IR Controller Interference All wireless equipment might interfere network signals of GSM unit and influence its performance Avoid Use at Gas Station Do not use GSM Gate Opener at a gas station Power off GSM unit when it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal shielded by covering the mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer D o gt eD 3 Standard Packing List GSM SMS Air Conditioner IR Controller X 1 GSM Antenna X 1 Inbuilt DS18B20 Temperature X1 Inbuilt Backup Battery X 1 Inbuilt User Manual X 1 Optional Accessories DS18B20 Temperature Sensors 12V1A AC DC Adaptor Wired PIR Motion Detector PIR 010r CPIR 03 4 Mainly Features Vv Can be operated from anywhere no distance limitation Vv No call charges for inquiry the GSM SMS Air Conditioner IR Controller rejects the call from authorized number then return status on the first ring Vv Multiple applications temperature monitoring intelligent air conditio
23. re version 13 8 2 Inquiry the GSM Unit current statUS 13 8 3 Remote Operate the Air Conditioner by SMS CommandS 14 8 4 Quickly Control Combination CommandsS 14 9 Technical specificationsS 15 10 Quality Warranty 15 11 AffixTableS 15 Table 1 Brand Air Conditioner Menu Code 16 Table 2 Operation SMS Command Table 17 Table 3 Quickly Control Combination Command Definition 18 Table 4 Installation Schedule 18 This handbook has been designed as a guide to the installation and operation of RTU5014 GSM SMS Air Conditioner IR Controller Statements contained in the handbook are general guidelines only
24. ry Settings The user can send SMS Command to inquiry the settings the command is After the GSM unit received will return H ENS Group L ENS 4 Group 7 4 Setup Nobody Onsite Automatically Switch OFF the Air Conditioner The GSM Unit supports intelligent management the user can setup how long nobody onsite then switch off the air conditioner automatically to save the power consumption This is very useful in lots of public rooms e g Class Room office room and so on The GSM unit will defect the connected wired PIR Motion Detector if the any person movement then will active the wired PIR Motion sensor continually and the GSM unit will not send IR signal to switch off the air conditioner if the PIR motion sensor hasn t been activated continually then stands for nobody onsite the GSM unit will send IR signal to switch off the air conditioner The user can setup how long nobody movement then switch off the air conditioner automatically The SMS Command is pudsBsTimertsSuSTextmessager pudsBeTimoss B B is the identification character of this command Time 000 999 unit is minute Stands for how long not active the Wired PIR Motion Detector should switch off the air conditioner default is 000 stands for disable this function SMSTextmessage Stands for SMS text message content that will send to the first Authorized Number while switch off the air conditioner by this condition Max 60characters If use the jpowd
25. s system is warranted to be free of defects in material and workmanship for one year 2 This warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by purchasers 11 Affix Tables Page 15 of 18 King Pigeon Hi Tech Co Ltd Page 150f18 Ver 1 0 File No RTU501410 KING PIGEON Se Table 1 Brand Air Conditioner Menu Code _ GSM Temperature Alarm GSM SMS Air Conditioner IR Controller Brand Air Conditioner Menu Code Menu Code A C Brand A C Type Qty A C Brand A C Brand A C Type Qty 0 Gree 21 26 Samsung 20 1 Aucma 20 27 Toshiba 10 2 Haier 19 28 Hitachi 20 3 AUX 20 29 National 30 Panasonic 4 Midea 20 30 carrier 20 5 CHANGHONG 20 31 FUJISU 20 6 Chigo 20 32 Sharp Sampo 20 7 Huabao 10 33 Daikin 20 8 Kelon 10 34 HYUNDAI 10 9 LG 10 35 Kolin 10 10 TCL 20 36 Shangling 7 11 Galanz 10 37 Electrolux 4 12 Hualing 20 38 Yingyan 9 13 Chunlan 10 39 Yutu 7 14 FRESTECH 10 40 Yangzi 6 15 Hisense 10 41 SAST 3 16 Weili 34 42 Chuanghua 4 17 Shinco 10 43 XIAOYA 3 18 GALUHA 7 44 Xinle 4 19 FEILU 10 45 KONKA 2 20 DongBao 20 46 Whirlpool 5 21 Dongxinbao 9 47 YORK 5 22 Changling 12 48 Panda 3 23 Lanbo 13 49 KangLi 3 24 Sanyo NEC 52 50 ROWA 3 25 Mitsubishi 49 Other
26. ture or control temperature in expected range The GSM SMS Air Conditioner IR Controller equips professional air conditioner IR encoder which with the compatible of almost all of the brand air conditioners The user can send SMS Commands to turn ON OFF change the air conditioner mode to Cool Dry Heat and Auto The GSM SMS Air Conditioner IR Controller inbuilt a temperature sensor inside measure range 55 C to 125 C the temperature sensor also can be extend to outside if required The user can setup high and low threshold value of the temperature when occurrence it will send SMS text message to alert the authorized users immediately Just dial from Authorized User number the GSM SMS Air Conditioner IR Controller will reject at the first Ring no communication cost then return the current temperature Air Conditioner Status AC power status and other information Also the user can setup the interval time to report these information to authorized number automatically Moreover the GSM SMS Air Conditioner IR Controller supports intelligent management while the temperature higher or lower than the threshold value it can automatically turn on the air conditioner and change to the preset mode also it can automatically turn off the air conditioner while detecting nobody movement in the setting time to save power consumptions 2 Safety Directions Safe Startup hd Do not use GSM unit when using GSM equipment is prohibited