1.      Enter PIN    User s Guide Galaxy Galaxy e 27    28 e Galaxy User s Guide Galaxy    Glossary of Terms    DAC    Door Access Controller    DHCP    Dynamic Host Configuration Protocol    DNS    Domain Name System    VO  Input Output    LCU    Logical Control Unit    MDU    Magnetic Door Unit    PIN    Personal Identification Number     User s Guide Galaxy Glossary of Terms e 29    Reader    Reader for checking access cards    Security group    A group of persons with a common level of security  A person can  belong to several security classes     SNMP    Simple Network Management Protocol    TFTP    Trivial File Transfer Protocol    30 e Glossary of Terms User s Guide Galaxy    Index    A    Activate Alarm  ON  24   Activate alarm with forced start  24   Alarm Operations 24    G    Galaxy 3  Galaxy Planning Guide 21    Inactivate Alarm  OFF  25  Installation 5    P    Prerequisites 4  Hardware 4  License 4  Line 1 4    User s Guide Galaxy Index e 31    
2.    GALANT bo       Example of Galaxy installation  with two Galaxy 60     With Galaxy 60  four LCU9016 controllers can be used per control  panel     User s Guide Galaxy Galaxy e 23    Alarm Operations    This section describes how to activate the alarm  i e  alarm ON  and  the procedure for inactivating the alarm  alarm OFF      Activate Alarm  ON   Press B     Swipe card     Enter PIN    Steps   When B is pressed and the card swiped  the green status LED is lit     When the PIN is entered  the green status LED first flashes and  then turns to a constant red light  This indicates that the alarm is  activated     Note  If the readers status LED first flash with a green light  then  changes to red and then changes back to green means that there is a  section in the installation that is open  In such case  check doors  and windows and make sure that no person is present     Activate alarm with forced start  Sometimes used for systems with glass break detectors     Press 9B     Swipe card     Enter PIN    Steps   When 9B is pressed and the card swiped  the green status LED is    lit    When the PIN is entered  the green status LED first flashes and  then turns to a constant red light  This indicates that the alarm is  activated     Note  If the reader   s status LED flashes with a red light without  changing into a constant red t  the alarm will not be activated until  the concerned section is reset    Check the alarm status by pressing B  swipe card    Constant red light   Alar
3.   the Galaxy system manuals      User s Guide Galaxy Galaxy e 3    Prerequisites    This section describes the prerequisites that must be met in order  for the Galaxy system to fully function together with ARX  ACCESS     Hardware    The controllers must be equipped with communication cards of the  type    9014 II    or later  This in order to have access to the sixth  terminal block which enables connection to Galaxy     License    To make the Galaxy functions accessible in the ARX ACCESS  client you are required to have a license that covers these Galaxy  features  Without such a license the Galaxy functions are not visible  to the user  but all the standard ARX ACCESS features will work     Communication line 1    The controller that is assigned a serial interface  RS232  Tele  module  ISDN or TCP IP  must be connected to the first  communication line of the Galaxy control panel  communication  line 1     Units that not are assigned a serial interface can be connected to  any of the communication lines     NOTE  Only one controller per installation can be assigned a serial  interface  Therefore for the other controllers the option Serial  interface must be set to    None    in ARX ACCESS     4 e Galaxy User s Guide Galaxy    Installation    To connect a LCU9016 controller to a Galaxy control panel  central  unit   follow these steps     1  Connect the outgoing lines A and B from the control panel   Galaxy  to the connections marked    A    and    B    on the  terminal bloc
4. Off      If doors connected to the controller 4 and 5 in the example are  included in an alarm zone  the units can be used for alarm  operations  On Off      A real Tele module is present in the installation and therefore can  this unit not be simulated  Controller 4 and 5 acts as virtual RIO  units  or VRIOs   These door units can handle alarm signals from  for example an intruder alarm  In the case of a valid passage the  alarm is turned off    gently    so that no alarm is triggered  If the door    User s Guide Galaxy Galaxy e 21    is forced open the alarm is triggered and the communication is  performed via the RS485 bus     Note that control panels of type 128  500 and 512 can not be  configured to have ISDN or Tele module on Line 1  Such units  must be connected to the control panels S3 terminal block  For  more information regarding RIO addresses and communication  units  please see the Galaxy system manuals     LIE    LOUS016       LH    GALAXY 128  20051       Example of Galaxy installation  Galaxy 128 500 512     In order to increase the number of sections and groups in an  installation several Galaxy 60 control panels can be used  All  connected control panels can be administered and configured from  ARX ACCESS via the LCU9016 controller and with the Galaxy  Gold software  The communication between Galaxy Gold and the  control panel Galaxy 60 is handled by the LCU9016  mo additional  modems or other connections are necessary     22 e Galaxy User s Guide Galaxy    
5. User s Guide Galaxy    ARX ACCESS    ASSA ABLOY    O Copyright 2003 2008  ASSA ABLOY  ASSA ABLOY  F  rmansv  gen 11    SE 117 43 Stockholm    Phone   46  0 8 775 16 00  Fax   46  0 8 775 16 20    UG 559 012 921F    Contents    Galaxy 3  About Galaxy alarm 3  Prerequisites 4   Hardware 4  License 4  Communication line I 4  Installation 5  Galaxy in the installation tree 6  Add Galaxy control panel 6  Connect controller to Galaxy control panel 8  Galaxy in the alarm tree 10  Add Galaxy zone 10   Add DAC 14   Add virtual RIO  VRIO  16  VRIO inputs 17  VRIO outputs 20  Galaxy Planning Guide  basics  21  Alarm Operations 24  Activate Alarm  ON  24  Activate alarm with forced start 24  Inactivate Alarm  OFF  25  Disarm after Triggered Alarm 20  Summary Galaxy Alarm Operations 27  Glossary of Terms 29  Index 31    User s Guide Galaxy Contents e iii    iv e Contents User s Guide Galaxy    User s Guide Galaxy Galaxy e 1    Galaxy    About Galaxy alarm    As an additional feature ARX ACCESS can be integrated with the  Galaxy intruder alarm system  If these two systems are integrated  you will get an overall solution which covers both access control  and intruder alarm monitoring     A complete Galaxy system consists of a number of modules  which  controls the alarm systems different settings and functions  The  main modules are     e Control panel  central unit   e Key pad  e RIO  Remote Input Output  expansion module     For more information about the Galaxy intruder alarm  please see
6. alaxy control panel that the zone shall  belong to     2  Then select the option Add in the windows menu bar  and  click Galaxy zone        Alarm tree    Galaxy zone       Menu for adding Galaxy zone    3  The symbol for the zone is now added to the alarm tree on  the left hand side of the window     10    Galaxy User s Guide Galaxy       Alarm tree                Settings   Access categories   Pre alarm config   i Alpha Zone   E   I Gala Mame Galaxy zone 2   Group 141  wt    Alarm bypass by schedule    Schedule   Always off w    Time limited disarming    Time fin minutes                 Galaxy zone selected and the tab Settings active    4  Inthe right side of the window under the Settings tab  enter  a Name for the new zone and add a brief Description  You  must also select a Group  Galaxy alarm group  for the zone  and choose settings for Alarm bypass by schedule and Time  limited disarming     5  In the same window  under the Access categories tab you  can enter the access categories that shall be valid for this  zone  Add categories by clicking the Add button  select a  category and then click OK    User s Guide Galaxy Galaxy e 11       Alarm tree      Mame   Description  Full access    Remove    Galaxy zone selected and the tab Access categories active       6  On the third tab  Pre alarm config  the operator can set the  Time in seconds before the alarm goes on and also connect  to a number of relay outputs to the zone    NOTE  No pre alarm will sound if you turn on th
7. at  section that set off the alarm     Inactivate Alarm  Method 9A     The 9A method will turn off the alarm directly and the alarm event  is stored in the history menu on the MAP     To enter the door and confirm the alarm   Press 9A     Swipe card     Enter PIN    Approach the MAP to study what section that set off the alarm     26 e Galaxy User s Guide Galaxy    Summary Galaxy Alarm  Operations    Tip  Cut out and copy this page and  distribute it to users of the system     Alarm OFF  Press A     Swipe card     Enter PIN  Alarm ON  Press B     Swipe card     Enter PIN  Alarm ON  forced   Press 9B     Swipe card     Enter PIN   May be required for systems with glass break detectors      Disarm after triggered alarm   For a regular door   enter and then confirm the event on the MAP   Press 7A     Swipe card     Enter PIN    For elevator   go to floor and and confirm the event on the MAP   Press 7A     Enter floor no      Swipe card     Enter PIN    For a regular door   enter and confirm the alarm   Press 9A     Swipe card     Enter PIN    For elevator   go to floor and confirm alarm event  Press 9A     Enter floor no      Swipe card     Enter PIN    Several alarm groups  or floors    If several groups  or floors  are controlled from the same reader   the groups  or floors  ID number is entered after A or B    Alarm OFF group 2  Press A2     Swipe card     Enter PIN  Alarm ON group 2  Press B2     Swipe card     Enter PIN    Alarm ON  forced  group 2  Press 9B2     Swipe card
8. e alarm  via a Galaxy key pad  MAP      12 e Galaxy User s Guide Galaxy       Alarm tree    Settings   Access categories                          Alpha Zone    Galaxy CE1 Time in seconds before alarm goes on    a 4 UCOO1a   Relay holder  Tabl   Relay posi     UcOO1a Controll    Relay 1             Galaxy zone selected and the tab Pre alarm config active       7  Select the Add button to choose which relay output and unit   controller or DAC  that shall be added  Highlight a unit   select relay output and click OK     8  Inthe Alarm tree window  click OK if you want to save the  changes and close the window  Click Cancel if you want to  close the window and not save the changes  Click Apply if  you want to save the changes and at the same time keep the  window open     User s Guide Galaxy Galaxy e 13    Add DAC  To add a DAC to a Galaxy zone  do the following   1  Highlight the Galaxy zone that the DAC shall belong to     2  Then select the option Add in the windows menu bar  and  click DAC        Alarm tree    Brea          is  Menu for adding DAC  3  In the window that now opens  choose the DAC to add  from the list over Available DACs     NOTE  1  A DAC can not belong to a Galaxy zone and a  standard alarm zone at the same time    NOTE  2  If you have an elevator in your Galaxy  installation  each DAC can only belong to one Galaxy zone     4  The symbol for the DAC is now added to the alarm tree     s         Alarm tree  R  0At   O Alarm F   E    Alpha Zone Show alarm statu
9. e field Name  and add a brief description     6 e Galaxy User s Guide Galaxy           Installation tree    or See Name    Building A    E MEU 08b  DoorGrp   E Galaxy CE1   oof  Office B2   F C Storage C3       Installation tree window with a Galaxy control panel selected    5  Click OK if you want to save the changes and close the  window  Click Cancel if you want to close the window and  not save the changes  Click Apply if you want to save the  changes and at the same time keep the window open     User s Guide Galaxy Galaxy e 7    Connect controller to Galaxy control  panel  To add a controller to a Galaxy control panel  do the following     1  Highlight the Galaxy control panel that the controller shall  be connected to     2  Then select the option Add in the windows menu bar  and  click Controller to serial line     a      Installation tree       Menu for adding controller to serial line    3  The symbol for the controller is now added to the  installation tree on the left hand side of the window     8 e Galaxy User s Guide Galaxy           Installation tree    GG Installation tree   3    FC House B  ef  Building A Serial interface   R5232 w    E E Storage C3    The installation tree with a controller connected to Galaxy       4  For each controller connected to a Galaxy control panel   enter the correct Line number and choose type of Serial  interface for the connection     NOTE  Only one controller per installation can be assigned a serial  interface  Therefore for th
10. e other controllers the option Serial  interface must be set to    None        NOTE  If there already is one unit in the Galaxy installation that is  communicating with the control panel through to a certain serial  interface  it is not possible to use the same interface for the  connected controller     For example  you can not select the option    RS232    as serial  interface for the connected controller if there already is an external  PC communicating with the Galaxy control panel via the RS232  interface     User s Guide Galaxy Galaxy e 9    Additionally  it is possible to replace the serial interface RS232 by  tunnelling the traffic between a PC with the Galaxy Gold software  and the Galaxy control panel over a local area network  LAN  via  the connected controller  In such cases you should in Galaxy Gold  create a TCP IP connection with the controllers IP address and port  number 4900     Galaxy in the alarm tree    If Galaxy control panels and connected controllers have been added  in the Installation tree window  these units will automatically  appear in the Alarm tree view  In the alarm tree it is then possible to  add Galaxy alarm zones and set alarm group settings for that zone     In ARX ACCESS it is possible to choose if a controller shall act as  a virtual RIO  or VRIO  In such cases the controller communicates  with the Galaxy system in the same way as a traditional Galaxy  RIO     Add Galaxy zone  To add a Galaxy zone  do the following     1  Highlight the G
11. k in the lower right corner of the 9014 card in  the controller cabinet        Diagram of the terminal block in the lower right corner of the 9014  card    The first from the left on the terminal block is labelled FREE and  can be used to join any additional wires  The FREE connection is  not electrically connected to the 9014 card     For additional information regarding the LCU9016 controller  please study the    ARX ACCESS Installation Manual     For further  information about the Galaxy units  see the Galaxy system manual     User s Guide Galaxy Galaxy e 5    Galaxy in the installation tree    In the ARX ACCESS client the specific Galaxy functions are  managed through two windows  Installation tree and Alarm tree     In the installation tree you add the Galaxy control panels  central  units  that are available  and specify which ARX controllers that  will be connected     Add Galaxy control panel  To add a Galaxy control panel  do the following     1  Highlight the level in the installation tree where the control  panel shall be located under     2  Then select the option Add in the window menu bar  and  click Galaxy control panel     i      Installation tree    a oe     i Folder       Controller  Offline b       Galaxy control panel    Menu for adding Galaxy control panel    3  The symbol for the new control panel is now added to the  installation tree on the left hand side of the window     4  Inthe right side of the window  enter a name for the new  control panel in th
12. m ON    24 e Galaxy User s Guide Galaxy    Flashing red light   The alarm is waiting for the incorrect section to  be restored before the alarm is turned on     Inactivate Alarm  OFF   Press A     Swipe card     Enter PIN    Steps   When A is pressed and the card swiped  the red status LED is lit     When the PIN is entered  the red status LED turns to a constant red  light  This indicates that the alarm is turned off     User s Guide Galaxy Galaxy e 25    Disarm after Triggered Alarm    When you arrive to a site after an alarm has been set off and try to  inactivate the alarm the normal way  with A   Card   PIN  the  readers status LED will not change to a green light  In this case the  LED will stay red and the buzzer will sound  This indicates that the  alarm has been set off  and there are two ways of opening the door   by using the 7A  or 9A method     The 7A method can not be used if there are additional detectors  between the door and along the path to the MAP  Because the alarm  is still activated these detectors will set off the alarm once more  when you enter the door  In these cases the 9A method must be  used     Inactivate Alarm  Method 7A     The 7A method will pulse open the door but does not turn off the  alarm  The alarm is turned off with the MAP unit and the alarm  event is stored in the MAP     To enter the door and confirm read the alarm event on the MAP   Press 7A     Swipe card     Enter PIN    Enter the door and approach the MAP to confirm and study wh
13. ol for the new VRIO is now added to the alarm  tree on the left hand side of the window     4  Inthe right side of the window  enter a Name for the VRIO   and choose the appropriate Address for the unit  There are  addresses available in the range from 0 to 15     NOTE  On communication line 1 it is quite normal that the  addresses 0 and   are already occupied by the Galaxy control panel   This may differ from installation to installation and it is therefore  best to first check which addresses that are available     16    Galaxy User s Guide Galaxy    VRIO inputs    Each VRIO has eight inputs and for each of these you can choose  what type of action that shall be reported back to the Galaxy control  panel  central unit       The Galaxy control panel decides the alarm reaction if  for  example  a door is forced open  The control panel settings are  configured through the Galaxy Gold software     This is done in two steps  first if the action concerns a controller or  a DAC and secondly what type of action  function  shall be  reported    For the RIO inputs dedicated to a controller  you can choose from  the actions LCU tamper or External power supply failure        Alarm tree    i    B Alarm     d Alpha Zone jien dhatan   Galaxy CE1 Adre   0   S  Galaxy zone 2   bef DACOO1a 1  UCOl Input   S  4 UCOO1a              1 Hl ene   RIO ID DACILCU Functionality   UCOO1a YI LEU tamper    S   xternal power supply                                       m                         DACILCU F
14. our RIO outputs available for each VRIO you choose type  of output  DAC or Controller  and then which relay that shall be  connected to this output     For a DAC output there are four relays too choose from  and for a  Controller output there are three relays too choose from        Alarm tree  RJ Aa      O Alarm  g  g Alpha Zone     Galaxy CE1  S  Galaxy zone 2  ff DACOO1a 1  UCOL Input  g g ucoota    i  8  RIO ID DAC LCU Functionality             Name VRIOO3             Address 0                1004  1005  1006  1007  1008                      Output       RIO ID DACILCU Functionality  UCOO1a v       v LEE        Relay 3  OBC m                      Alarm tree with RIO output option selected    20 e Galaxy User s Guide Galaxy    Galaxy Planning Guide  basics     With a control panel of type Galaxy 60 all communication units can  be simulated by one controller of type SOLICARD ARX  LCU9016  The different Galaxy communication units are  TCP IP   ISDN  RS232 and Tele module     The communication units can work together with the controller  SOLICARD ARX LCU9016 if the units are not occupied by an  existing  physical  unit in the installation  The communication unit  are used for alarm operations  On Off  via the Galaxy central unit        LOUS016 LOLUISO1B    Example of Galaxy installation  Galaxy 60     In the example above  see figure   one controller simulates the  serial interface TCP P  ISDN or RS232  All readers connected to  this units can be used for alarm operations  On 
15. s when armed for   No one    Galaxy CE1     Galaxy zone 2 Authorised to enter armed area No  normal     me ent  OACOO1a 1  UCO    Hg UCOO1a Status indication time   10 0             Allow arm   Allow disarm      Permanent alarm indication   CJ Unlock door when disarming       Do not block door             The alarm tree with a DAC in a Galaxy zone selected       In the upper part of the window  on the right side  you can choose  alarm settings for the selected DAC  The three first options control  settings for alarm status and access to alarm zones     e   Show alarm status when alarm for  where the options are  No one  Authorized users or All     e Authorized to activated alarm zone  where the options are  No  Alarm authorized  Alarm authorized with PIN  Alarm    authorized with warning or Alarm authorized with PIN and  warning     e Time for showing status  is defined in seconds     In the same window there are five check boxes for additional alarm  settings for the DAC     e Allow arm  e Allow disarm    e Permanent alarm indication    User s Guide Galaxy Galaxy e 15    e Unlock door at disarmed area    e Do not block door    Add virtual RIO  VRIO     To each controller connected to Galaxy you can add a number of  virtual VRIO s     To add a VRIO  do the following   1  Highlight the controller that the VRIO shall belong to     2  Then select the option Add in the windows menu bar  and  click VRio           Alarm tree    ROA      vRIo P    Menu for adding VRIO    3  The symb
16. unctionality  DACOO1a 1                                  Alarm tree with RIO input option selected  LCU     User s Guide Galaxy Galaxy e 17    For the RIO inputs dedicated to a DAC  you can choose from the    actions     Door forced open  initiates alarm if the door is forced open   no information sent at valid passage     Door open o long  initiates alarm if the door stays open to  long after a valid passage     Door forced open or door open to long  same as the two  options above     Assault alarm  sends alarm when the PIN code is raised by  1000  Example  ordinary PIN    1234        assault PIN  2234        Invalid PIN  initiates alarm if an invalid PIN is entered    Free indication input  unbalanced input for logical  functions by the Galaxy control panel     Day Night input  same function as above but only acts if a  motorised lock is installed     Door open closed  sends status to the Galaxy control panel  regardless of if the passage is valid or not     18    Galaxy User s Guide Galaxy    Alarm tree    IR      GA         Alarm    Hy Alpha Zone   IG  Galaxy CE1    Galaxy zone 2  lf DACOO1a 1  UCO Input  Sg UCOOLa     H RIO ID DACILCU Functionality  DACOO1a 1 w   Door forced open v IA    Door open too long  Door Forced open or do  Assault alarm   Invalid PIN          Name VRIOOS          Address  0                            DAC LCU  DACOO1a 1                Alarm tree with RIO input option selected  DAC        User s Guide Galaxy Galaxy e 19    VRIO outputs    For the f
    