Home

CP-System User's guide

image

Contents

1. E BI A rectangular coupling TYPE2 A2 h prey BI A round rectangular tee piece A3xB3 I A round coupling 902 dt Systems Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Round fittings an annex to specifications made in CP System A round pipe A round duct fit A truncated round duct A real fitting with a nipple ending F 0 and a muff ending E gt 0 A two segment elbow D2 t a IF A segmented elbow D2 A round rectangular tee piece D3 r aD3 A3xB3 L5 y L3 E a L3 oD o2 D 202 a D w L L L Q A cross A cross with reducer A reducing cross A taper tee piece 9D3 oD3 D3 oD3 L3 4 L3 h n LKO o2 a Taht 02 aD N e A tee piece branch A tee piece branch oblique A round cap A round flange E oD L p 7 g D P dpi external XY2 ASS gD gD oD vyz oD S Q o aro ae E93 EV Le e A muff A nipple A coupling A taper saddle A formed saddle A pressed saddle B ii gt S am 902 no 902 602 oh 4 N 4 gt HH elh E a ote a Era oD Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk
2. L A left edge R A right edge An example of drawing by edge with the distance from walls y NZ NI N NI The direc N y tion of Y drawing Z P1 P4 The edge Right The distance 300 E So N The direction of drawing When sequence is drawn it is necessary to join pipes using tee piece Join pipes ducts command should be used to do this easy point P7and P8 LLL LLL LLL MMANSASMAASSAS XSAN he edge Left he distance 300 45 62 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Joining pipes ducts cable trays To create installation quickly and easy a user should draw only pipes ducts cable trays or sequences of pipes ducts cable trays and then join them using a versatile command Join pipes ducts CP System lengthens or shortens joined pipes ducts cable trays intelligently as well as inserts optimal fittings automatically Once a user has run the Join pipes ducts command he should select pipes ducts cable trays to join them Depending on how they are placed on the drawing appropriate fittings will be suggested to insert A dialog presenting parameters of appropriate fittings is the same as in the Pipes Ducts Cable trays command Some parameters and dimensions are disabled For example joining pipes ducts cable trays by means of reducer disables
3. O Sot Show category Use Current unit millimetres Cable trays plan 2D S Cable trays steel T Cable tray J Bend E Elbow Type Reducer Producer and type A Fuler TK REM A Fuller bend E Tee piece Cross Cable tray tuncated Elements Z Z o User objects defining Installation and drawing Wh Cable tray Cable tray Installation Type KPz Blacha 0 55 8 50 Product KPZ 100850 055 Dimensions Dimension A Cable ladders Dimension B Floor trays Options Plastic trays Protective pipes ir Installation fit th and height fit Continue with a pipe Hoos Join object Producer Specify a producer Select to set all parameters by yourself Description Current unit centimetres 76 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Lighting and other objects Lighting and other objects Lighting The Objects and lighting command enables a user to select and to insert binding lights into projects Catalogues of binding lights were prepared ac cording to catalogues of known manufacturers In the program there are also general binding for which a user can specify any dimensions After a user has inserted an object in a drawing he can specify their parameters manufacturer type etc These data will be considered for specifications Binding lights as CAD objects are inserted in the same
4. A user can copy and distribute the LLview11 exe program for free This program is translated into many languages it has a small size and does not need any special hardware configurations Thanks to it a user can create files in LL format and make them available with a viewer Both LL files and a viewer can be attached to an e mail and sent between coop erating companies from any countries No one should have any problems with opening and printing LL files Command line From AutoCAD 2006 and in IntelliCAD it is a possible to turn off com mand line AutoCAD IntelliCAD and CP System application display im portant information in a command line Because of it a user should turn on a command line with at least two visible lines Ma4 lnh Model Layout A Layout E corner rectang C hamfer Elevation Fillet Rotated Square Thickness Width lt Select f irst corner of rectangle gt ther corner of rectangle Ready 3 1490 1 2640 0 0000 O ByLayer ByLayer Standard Standard Command line of AutoCAD program A user can turn on a dynamic command line from AutoCAD 2006 A dy namic command line displays only one line furthermore it can slow down an application e g during editing many objects simultaneously That is why a dynamic line is turned off by many commands of CP System The dynamic command line of AutoCAD Turning off both classical and dynamic command line is particularly in convenient because a user will not
5. E F 50 2 00 Supply air Tee piece D 300 D3 300 L 400 L3 200 a 90 400 1 00 Supply air Tee piece branch D 300 D2 200 D3 200 L 423 xY 2 250 xY 3 300 423 1 00 The Area column contains the area of an element in m or total area of all elements exported in a given row of a specification e g 15 209 m for 300 duct The Sum column contains total length of pipes ducts cable trays in meters A column Sum is used only in specifications with an option Summing data markered e g the total length of 300 ducts is 16 14 m System Name Article Area Sum Supply air A pressed saddle D2 160 D 200 L 200 a 90 0 151 1 00 Supply air Duct D 160 0 461 0 92 Supply air Duct D 200 2 262 3 60 Supply air Duct D 300 15 209 16 14 Supply air Elbow D 300 R 450 a 90 F 50 1 884 2 00 Supply air Tee piece D 300 D3 300 L 400 L3 200 a 90 0 565 1 00 Supply air Tee piece branch D 300 D2 200 D3 200 L 423 xY 2 250 xY 3 300 E F 20 0 961 1 00 Fittings Type or dimensions of fittings are exported in a column TYPE All dimensions are com patible with dimen sionns on drawings in the list of 2D fittings The Area column can For fittings the be considered in air column Sum conditioning installa contains total tions This column amounts of contains the area in fittings of a m of elements calcu given type lated according to EN 14239 norm e g there are two 90 elbows with 300 diameter and the
6. Note The commands work correctly in drawings in which a structure of layers of CP System program is used CAD Profi Options Show 2D layers Show 3D layers Show all layers Freeze layer groups gt Blocks descriptions Thaw layer groups gt Axes Hidden Add block to library Details Ta User object library BF User symbols library Dimensions in block Special il Title tables 5S Specification Architecture Heating AX About Aircondition P Hep Plumbing Electrical installation Controlling 110 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Extending contents of the program Extending databases of the program Extending contents of the program The program has an open structure Thanks to this a user can add new elements as well as extend available databases It is also possible to add user s pipes ducts cable trays symbols objects parametrical devices tables and frames etc Command Add block to library is a very convenient tool to do that This command adds automatically blocks to the working folder Extending databases of the program There are available buttons that enable a user to extend and edit databases of the program in many dialogs a Add The button enables a user to add a new element to database The most often this element is added to the User category Copy Copying a selected element to the User category With the use of c
7. 401 339 200 9185 6200 160 Other commands to insert objects 9185 Pump 2 l 100 339 In CP System program there are additional commands that enable a user to insert objects Plumbing objects plan Radiators Duct devices etc Example Duct devices can be inserted in 2D ducts from which they copy properties of the system supply air exhaust air etc Dialogs can be little bit different than described before thanks to that a user can select and insert required object as easily as possible 49 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Plans and sections Radiators In the Radiators command there are databases with catalogues of radia tors They are displayed in a dialog A user can enter dimensions of radiators on his own only for the first element on the list The rest of radiators have specified a type and that is why their dimension should not be changed Radiators a Search Heaters Name Length Thickness Height Z El Panel heater m Pane heater 100 Panel heater with thermostat E11 A 300 ae bee 11 300 400 40 eee ae ia 11 300 600 60 11 300 800 80 Convector 3 Radiator 1 30071000 100 Typical heater 11 300 1200 120 30 11 300 1400 140 30 6 30 6 6 6 6 Panel heater 6 11 300 1600 160 6 30 6 6 6 6 6 30 30
8. A very convenient way is to create 3D model based on 2D plans 3D model is used to obtain e g per spective as well as isometric views 3D technology also allows to detect potential mistakes and conflicts easier and makes the documentation to be more readable and clear The 2D 3D command generates 3D model based on 2D plans It is also possible to make the reverse operation inserting 2D blocks based on 3D model The command can only be used for devices that have defined 2D and 3D blocks simultaneously Once a user has run the command he should select the object s The next step is either to enter a value of level on which inserted objects will be placed or to choose one of options Layer or Point Enter level or Layer Point lt 1300 gt Selecting the Layer option causes all objects on a given layer to be proc essed The objects are placed on a level specified in triangular brackets Selecting the Point option enables a user to specify 3D point The Z coordi nate of this point specifies value of level on which a new 3D object will be placed Note e The 2D 3D command is not available in IntelliCAD program 91 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Attributes and descriptions Attributes and descriptions During inserting symbols and objects CP System adds to them descriptions parametrical data etc These data are stored as an attribut
9. Dimetry 45 angle Miniatures There is used a miniature view of symbols and objects in some dialogs A user can change the size of miniatures and their style aoe gt H a a Angular v ziea ES Esl Gate valve Safety valve Pump Miniatures with labels Miniatures without labels 3D style size 70 flat style size 80 Option Enable 3D blocks in IntelliCAD In IntelliCAD there is an additional option Enable 3D blocks in IntelliCAD Only if a user uses IntelliCAD version where edition of 3D objects is possi ble can his option be turn on Option Set high level of warnings Many messages and warnings are displayed in a command line by CP System It is related to informational messages which are not critical When a user has turned on high level of warnings some messages will be displayed in a dialog and it will be necessary to close them 18 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Settings and interface of CP System CAD Profi Options On line update Manufacturers libraries are updating systematically in CP System program Content is expanded and new functions are added System of automatic program updating by the Internet was introduced in order to update new elements quickly This program works similarly to Windows updating When a user has turned on the Pro po
10. It allows a user to add new catalogues to CP System at any time He can do this by installing of new libraries obtained from manufacturers Many libraries of manufacturers are available in the program Products library command enables a user to select an active library Once a com mand has been run a dialog is displayed in which a user can select a re quired library A Select folder S E Cablofil E C CP Producers on line Download CAD Efar w EMB Fujitsu H E Gestra S E Graziadio S E Immergas E Junkers A Ksb Legrand Polna SA S O Reflex w Salmson User data S O Vailant Viessmann 2 wio O Wilo CAD Library Online g Cancel ok After a user has selected a library a dialog is displayed in which he can look through devices or schemas of selected manufacturers Structure of libraries can be different for every manufacturer Because of that dialogs with elements from libraries can be also completely different There are the same options as e g in Plumbing objects plan or Paramet rical objects commands in every library 90 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Command 2D 3D The Working folder library is intended to create new CAD libraries and to extent the contents of the program by a user see page 111 Command 2D 3D A user can use 3D objects in his own designs
11. Numbering command must be used to remove numbers from objects totally In order to remove numbers a user should start the Numbering command and then select an object that has got a number P1 It is also possible to select a text with a number CP System will suggest a mode of removing numbers Bricscad 9 This object has already got a number W1 Do you want to switch to remove number mode After a user has activated a mode of removing of numbers he should select required objects or numbers P2 P3 Assigning of numbers as well as texts and leaders are removed for selected objects W 1 WI W2 w3 xX P3 P1 W 6 W 6 W 4 a P2 Wo 99 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Numbering of objects Copying objects with numbers During copying numbered objects target elements are treated as ob jects without numbers Copied objects should numbered again if necessary If texts of numbers are copied during copying e g by means of CAD com mand Copy then these copies are only graphical objects with no meaning They are invalid from CP System s point of view The invalid texts of num bers should be removed from a drawing To do that a user can use the mode of removing numbers in the Number ing command After the command has been started a user should select invalid text and then select removed
12. Tel 46 35 7777030 www jl systems dk Settings and interface of CP System Commands repeating CPX Commands repeating CPX Either a right mouse button or ENTER are used to repeat the last command in AutoCAD or IntelliCAD It is often necessary to use alternately CAD pro gram commands e g copy as well as CP System commands e g inserting symbols That is why CPX command was introduced It repeats the last command of CP System application To use this command a user should enter CPX command in AutoCAD or IntelliCAD command line and press ENTER CAD Profi Options The CAD Profi Options command is used to specify basic parameters of CP System program W Settings Units Block layer millimetres automatic O centimetres O metres vV Sets the global linetype scale factor current for unit variable _Itscale C Extended layer name Variable _Itscale 100 O fired Thumbnails Isometric style Thumbnails size 70 Angle J 3 3D style thumbnails O45 Thumbnails labels O Other Propose checking of updating on line every 15 days v Update now Set high level of warnings V Enable 3D blocks in IntelliCAD requires ACIS AT Program registration 4 Units It is recommended that a user creates drawings at a scale of 1 1 in CAD programs The scale of the drawing is specified only during printing Example Real dimensions of inserting device are 600 mm x 400 mm If
13. Type is equivalent to a pa rameter Symbol or Mark Example A table contains columns No Symbol Type Description Sum In this case a user should select columns Type and Name in Specification Wizard The Sum column will be filled when the Summing option is active A column No is filled when the Ordinal number on print option is active W Legend specification Specification style O Legend Settings Multiline Single line O up down with serial number 6 columns 4 columns H E numbering 6 columns ll data in a Name or Description box Layers in CP System Layers of AutoCAD are being created automatically during designing in CP System program In order to manage these layers easy a lot of commands in main menu of the program are available Using the CAD Profi Options command a user can specify on which layers the program is to place various elements It is recommended to turn on automatic managing of layers It is also possi ble to insert all elements on a current layer manual managing of layers by a user or on a layer with a fixed name 108 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Layers in CP System Automatic managing of layers allows a user to keep order in a created draw i
14. are divided in this option If there are many objects to process an operation can be long lasting Therefore a status of processing is displayed in the command line e g Done 70 The Select option allows a user to select any pipes ducts cable trays to divide After choosing the option the length of sections should be specified The byPipe option enables a user to select pipes ducts cable trays intelli gently After choosing the option an object belonging to a given system should be selected Afterwards the other objects should be selected e g using window selection mode Only elements compatible with a previously selected object will be selected elements belonging to the same system or installation the other will be filtered out An example of using the byPipe option Select pipe or Layer All Select byPipe P Select 2D pipe auser should select an object from a required system Select 2D pipes a user should select other objects Specify length of segment lt 500 000 gt 1000 73 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Electric schemas Electric schemas Schemas of electrics are created similarly to schemas of plumbing heating or air conditioning installations Intelligent symbols cable trays as well as func tions for descriptions are available In electric module there are a lot of symbols They were divided into two basic
15. bt Stop valve p4 Four way valve pd Three way valve D4 Angular valve pt Safety valve D4 Routing control valve D4 Swing check valve pa Pump D4 Pump pa Pump Gate valve Safety valve Pump Control val _Cap valve Non return D4 Pressure reducing valve p4 Ball valve D4 Flanged ball valve pt Ball valve Stop valve Routing c Pressure r Drain cock Shutting flap Drain valve pe Control valve pt Drain cock pt Sludger De Filter Four way Swingche Ballvalve Sludger_ Butterfly v Non retum be Filter pt Cap valve Shutting flap s Diiu niske Angular v Ball valve Non return Show norms v System Supply Angle Mirror and isometry Symbols size Mirror x Mirror Y Seale O Rotate aAnge 9 Isomety Current unit millimetres IEG Hep Seach Cancer _ bE Insert symbol Insert symbol Insert repeatedly Symbol options e Scale it specifies size of inserted symbols see page 23 Some symbols size has to be fixed so possibility to change a scale is disabled for them In this case a default scale is set An example of such symbols can be views of plumbing objects that are 26 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas used on plans The scale suits to v
16. button The command works in two modes Legend and Specification The Legend mode is used to make any defined legends or tables A 106 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Specifications user can specify a total width of a table distances between particular col umns and rows as well as the size and the style of the text A legend can contain a header with a title of a specification and with titles of particular columns The Description column has a special meaning After a user has turned on the All data in a Description column a legend will be created where all data from a drawing will be consolidated to one column When turning off this option it is possible to create tables that contain many columns When a user selects the Block column in a Specifications Wizard leg ends containing views of symbols and objects will be created Particular symbols in a legend can be placed on layers that are compatible with layers of symbols in a drawing Thanks to this symbols in a legend will have colours and other properties of original objects from a drawing Note Legends containing symbols are created only on the base of a cur rent drawing summary graphical legend containing data from several drawing cannot be created The width of particular columns of legends are specified proportionally to the width
17. cable trays and fittings Parameters of bends and elbows are specified in the left part of the dialog but some of them e g installation manufacturer type are copied from pipes ducts cable trays The reference edge and the offset A sequence of Installation and drawing pipes ducts cable trays can be p Masda Bi Sion or drawn by axis by left or by right Sc Offset 5 Axis R The Offset parameter specifies P Lek the distance of a geer and tee pipe duct cable tray from speci fied points The distance is counted from the axis or from a selected reference edge Producer The manner of drawing During drawing a user should specify points P1 P2 etc In case of drawing by axis with no distance pipes ducts cable trays as well as appropriate el bows and bends are inserted along the path of drawing Flex pipes Round pipes Rectangular pipes with bends Rectangular pipes with elbows In case of drawing with a given distance pipes ducts cable trays as well as appropriate elbows and bends are inserted in a distance from specified points 61 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings OO li lok P Distance 300 mm The direction of drawing f 4 x ar left edge A wall A left and a right edge are set in the direction of drawing of pipes ducts cable trays
18. rows up Move selected rows down Remove selected rows and Copy selected rows x The Save as a structural wall button enables a user to save a whole definition of a wall It is also possible to save walls that consist of single layers It is used to store various thickness for walls of specified types e g a supporting wall 18 cm a supporting wall 24 cm etc In case of adding to a list structural walls whole list of layers is replaced with elements from an added wall Drawing of walls After a user has selected layers of a drawn wall and clicked a button OK he should specify points between of which the program will draw segments of a wall The way of drawing is similar to drawing lines in CAD program During drawing it is possible to use various options in the command line Specify first point for a wall Specify next point or Undo Specify next point or Close Undo The Close option enables a user to close boundary of a building or room automatically The Undo option enables a user to move back to a previous point Thanks to that it is possible to correct designed walls without cancel ling of drawing Walls can be drawn by axis by left or by right edge Left and right edge are determined by the direction of pipes drawing points P1 P2 While a designer is drawing by left or right edge he can specify the distance from drawn points Thanks to that it is possible to draw walls in distance from other element
19. 30 Panel heater Smooth tubular heater 11 300 1800 180 30 Finned tubular heater 11 300 2000 200 30 Smooth collector tubular heater 300 2300 230 30 Finned collector tubular heater 300 2600 260 30 L Connections 300 3000 300 30 Purmo H 300 H 300 H 450 OOOOoOoOoOoOoOoooo0 moO View and insertion point Parameters Insertion point System On Length Thickness Height Levet O Scheme Panel heater Current unit centimetres x Cancel Plumbing objects In the main dialog there are miniatures of views of objects They enable quick selection of a re quired element Double dr Oval sink Single wa Toilet bow Wall urinal Toilet bow Washbasi Washing mpi machir Toilet bowl Wall urinal Washing Rectangle Floor inlet Shower tray Storm valve Toilet bow Dishwasher Oval sink Shower tr 50 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Pipes ducts cable trays and fittings A user can design plans and sections of plumbing installations air condition installation and cable trays During drawing installations pipes ducts cable trays and fittings elbows reductions tees are available Each fitting is a parametrical object that is drawn with the use of a
20. Back Left side Right side Schema specifying the type of added blocks One device can have a several separated blocks dwg files with various views in CP System program After a user has finished the command the names of dwg files added to a library will be preceded by prefixes indicating a type of a block 2D 2D block plan e g 2D_ju001 dwg 3D 3D model e g 3D_ju001 dwg PD front view e g PD_ju001 dwg TD back view e g TD_ju001 dwg RD right side view e g RD_ju001 dwg LD left side view e g LD_ju001 dwg The Automatic option enables automatic recognizing of type of added blocks on the base of prefixes of name files 2D PD 3D etc In case of adding symbols to the program a user should select the With no adjustment option thanks to what names of destination blocks will not changed Prefix of block names possibility of specifying a fixed prefix that will be added to every name of a block Various blocks have to have unique names in AutoCAD and IntelliCAD programs Using prefixes allows a user to change names of blocks easily names of files without manual edition of every block Add to database saving information about added blocks to data bases In case of turning off the Add to database option dwg files will be processed as well as files of s d slides will be created Processing blocks without saving in database can be used e g to update blocks that
21. D P2 f Ea N D gt me J 4 P2 i a 64 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Two pipes ducts cable trays that are not coaxial and with different diameters inserted at the same angle An asymmetrical reducer is inserted Two pipes ducts cable trays that are not coaxial and with the same diameters inserted at the same angle A fuller is inserted Two pipes ducts cable trays with the same diameters inserted at different angles An elbow or a tee piece are inserted For tee pieces main pipe duct cable tray should be selected as a first one Two pipes ducts cable trays with different diameters inserted at a 90 angle regarding to them selves A reducer elbow or a tee piece are inserted P2 P1 gt HH 7 ure or Sy Pid a ai o gt fee De H C P1 P2 D gt 65 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings For tee pieces main pipe duct cable tray should be selected as a first one Two pipes ducts cable trays with different diameters inserted at an angle other than 90 regarding to themselves A tee piece is inserted A main pipe duct cable tray should
22. Dishwasher Washbasin lt gt Angle Mirror and isometry Symbols size Mirror X O Rotate Scale Angle 0 Inserting symbols on schemas The inserting point for all plumbing objects is defined on the level of the floor Therefore before inserting the first symbol a user should draw a section of ceilings Inserting symbols of plumbing objects on schemas a user should always select a point lying on an upper edge of a floor P1 a 44 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Plans and sections Plans and sections A designer can design various plans and sections of installations in CP System program During designing a user can use objects as well as pipes and 2D fittings Various types of objects are included in CP System e Heaters are available in the Radiators command It is possible to use radiators on plans and schemas Usual objects are available in the Plumbing objects command Usual objects present views of devices in a very general way e g views that are compatible with norms or simplification of views For usual objects it is possible to specify only the external dimensions length width height Parametrical objects are available in the Parametrical objects com mand These objects display real views of devices such as containers dis tributors pumps etc A user can specify man
23. Load bearing wall Wall installation W Curtain wall C Isolation E Air space Structural walls O Examples W Outer concrete wall isolated 24 8 4 12 E Outer wall 36 6 4 12 E Load bearing wall 24 Concrete 35 E Concrete 25 E wall installation 7 Sort V Show category User Help Definition of layers of a wall Name Thickness E Concrete E Mineral wool E Air space W Clinker Wall installation Load bearing wall E Isolation Edge of drawing and distance O left Distance lo Current unit millimetres Before drawing walls it is necessary to specify layers of walls or select a previously saved definition of a structural wall 78 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Architecture Walls Selection of layers of a wall In order to add a single layer material to a list that contains a definition of a drawn wall a user should highlight a required element in the right part of a dialog and then click the Add an element to a list button Layers of a wall can also be added to the list by a double click or selection of the Add to a list option from context menu a right mouse button An element that is being added is inserted at the end of the list with default thickness It is pos sible to change thickness of every layer of a wall An order of elements added to a list can be organized with the use of buttons Move selected
24. When an angle is specified from 30 to 120 the texts are readable enough Matching of an attribute angle 30 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Cross symbols The Cross symbols command is used to insert symbols in a cross of two pipes W Plumbing heating Cross symbols Armature a pd Four way valve ot Three way valve D4 Angular valve od Angle safety valve pt Overflow valve od Three way cock pd Four way cock D4 Thermostatic valve angle pe ot Angle safety valve pa Non tetum valve with discha p4 Angle safety valve straight fl D4 Direct acting safety valve p4 Two way valve with servo de D4 Angle floating valve D4 Angle check valve D4 Angular cock Thermosta Non retum Angle che Three way Angle safe Angular c Three way Four way Direct acti Thermic st Heat exch Two way When a user has selected a symbol and specified his size scale he should press the button OK Then he should specify a first pipe P1 and a second pipe P2 The symbol will be inserted automatically in the point of crossing of specified pipes P1 PZ gt Notes If specified pipes are crossing at a right angle automatic fitting and breaking of pipes will occur 31 JL Systems Group Slottsmollan 302 31 Halmstad Sverig
25. a dialog is also possible to add additional data to a right panel and to organize them Specifications can be printed in a vertical or a horizontal order More columns can be selected for a horizontal order Using additional parameters If additional parameters were defined during describing ON ps 8 objects they will be available in a left panel of a dialog Flow now These parameters can be added to a right panel of fhe course and thanks to this they will be taken into account in Layer a specification Lenath Defining additional parameters is described on the page 95 101 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Specifications Options of specifications The Summing data option enables a user to make summary specifications with summing of amount of the same objects The lengths of pipes area of ducts and fittings etc can also be included The Sort option is used to sort data on plots initially Data can also be sorted in the next dialog containing initial preview of plot The Skip special symbols option causes blocks with no NAME attribute or with empty NAME attribute not to be taken into account in specifications Blocks that are used to describe a drawing symbols of pipe slope marks of amounts of electric pipes are not taken into account in specifications as well A column with ordinal number adding a column wi
26. as if only a block being created was visible on the screen Files created during adding blocks to library of objects Blocks are saved in folder C CadProfi Producers Working_folder Block Slides are saved in folder C CadProfi Producers Working_folder Slides Files of data about blocks C CadProfi Producers Working_folder cp_DevicesN uuc A user can edit these data after pressing Library editing button in dialog Add blocks to library Files created during adding blocks to library of symbols Blocks are saved in folder C CadProfi Producers Working_symbols Block Slides are saved in folder C CadProfi Producers Working_symbols Slides Files of data about blocks C CadProfi Producers Working_symbols S ymbWorkN uuc A user can edit these data after pressing Library editing button in dialog Add blocks to library Notes e C CadProfi a default folder of CP System program e Some releases of IntelliCAD program create slides preview only with a part of a screen Therefore by trial and error method a user should specify an optimal view during adding blocks to libraries In case of errors closing and reopening of IntelliCAD should be made 114 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Extending contents of the program Edition of data in libraries Edition of data in libraries The program enables a user to edit basic data such as name of devi
27. be selected as a first one Two pipes ducts cable trays with different forms inserted at various angles regarding to themselves A round rectangular rectangular round tee piece is inserted A main pipe duct cable tray should be selected as a first one Joining of coaxial flex pipes ducts with round pipes ducts The same diameters no fitting is inserted ig i ok P1 66 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Joining a flex pipe duct with a round pipe duct Both are inserted at the 2 same angle alles A round reducer is inserted Joining a flex pipe duct with a rectan IP 2 gular pipe duct that are inserted at the same angle inserted Three round pipes ducts with a differ ent diameters Two pipes ducts are coaxial and the third one is inserted at A rectangular round reducer is a different angle E gt A tee piece with reducer or a re D gt ducing tee piece are inserted l H i gt gt e Joining flex pipes ducts with other pipes ducts that are inserted at differ ent angles rules as for round pipes ducts e Some joining cannot be done because there are no appropriate fittings to do them e g there are no flex tee pieces e Itis impossible to join pipes ducts cable trays belonging to different systems If this joining is
28. click a title of a required column Re click causes data to be displayed in inverse order It is possible to sort many columns In this case a user should sort the lowest priority columns as a first In order to remove all rows of data a user should mark a required rows and press the Delete button If a designer wants to change the width of a column he should place a cursor between columns A cursor will change itself for two way arrow that enables change of the width of column by dragging Selected columns can be hidden in this way This possibility is useful for hiding empty columns or columns that are redundant on plots but were important by sorting data A title of plot should be specified in a window of preview It is also possible to define a header of a plot address as well as logo of company W Data printing from current drawing You can sort data and specify width of columns Title REMERA Down XK Remove Control valve Flanged ball valve Pressure reducing valve Safety valve Stop valve Swing check valve User data Csv export Print The Print button enables a user to print or export data to many formats The Csv export button enables a user to export data to a csv file that can be loaded to MS Excel Open Office or other applications The Draw button is used to create a graphical legends and also to fill drawing specifications tables 104 JL Systems Group Slottsmollan
29. command a user should create a slide a file that contains a preview of a schema The file of the slide should be saved in the C CadProfi UserData Components Sanit Slides folder e Add an entry to the file C CadProfi UserData Components Sanit Schem_hs uuc which contains definitions of available schemas Details about edition of a file are de scribed at the beginning of this file Notes In order to edit uuc files a user can use e g a system notepad The folder C CadProfi is a default folder of an installation of CP System program Many ready schemas are also placed in manufacturers libraries which are an integral part of CP System 43 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Plumbing objects schemas The plumbing objects are special kinds of symbols that are used on schemas of plumbing installations It is necessary to keep the vertical scale on plots That is why symbols of plumbing objects are inserted in standard size The size only depends on the unit of designing mm cm m therefore an option of changing of a symbol scale is disabled Plumbing objects can be inserted on the right or left side of verticals For some symbols Mirror X option must be turned on A user should insert symbols of plumbing objects at an angle 0 Washing Oval sink Double w Shower tr
30. command is described in details in chapters about edition of schemas on page 32 A user can add his own symbols and marks to the program with the use of the Add block to library command User s symbols are added automatically to special Working_symbols library see page 111 89 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Manufacturers libraries General commands Except for commands and objects used directly during designing of installa tions commands and functions supporting designing of installations are also available Manufacturers libraries Objects from libraries of manufacturers CP System includes CP Manufacturers libraries module Because of that devices of known manu facturers are available not only general and parametrical objects All objects from manufacturer libraries have views that present in details particular de vices Most devices includes technical data as well as catalogue cards Manufacturers libraries can occupy much space on hard disk and that is why during installation of the program a user can choose only some libraries He can also install selected manufacturers libraries without copying data on a hard disk in such case objects from manufacturers libraries will be inserted directly from CD ROM Libraries are also distributed by manufacturers that have license for CP Manufacturers program
31. command to edition of fittings was used In this command a new dis tance between axes was entered XY2 300 Pipes plan 2D Duets round amp Tee piece branch Installation Producer and type Producer Type Product i Dimensions Diameter D Diameter D2 Diameter D3 Length L Length automatically Distance XY3 i Dimensions E and F Dimension E Dimension F Options installation f Distance XY2 v Description Current unit millimetres Installation and drawing Specify the distance XY2 200 200 00 300 00 300 I supply air 450 400 400 767 oO 600 E 0 F 0 o o m A dialog for edition of fittings 70 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Change of the system for fittings All elements that belong to the given system or to the installation in the pro gram CP System are placed automatically on a separated layers If a user wants to change the system for selected elements he can move them on the other layer In AutoCAD IntelliCAD program there are many ways of changing a layer of objects Using a versatile command to match properties is a very conven ient way ss Buttons Match properties on the standard toolbar of AutoCAD and Match in the program IntelliCAD Example In order to change t
32. drawing pipes in isometry To shift quickly between planes during drawing the F5 key can be used Drawing in isometry e Dimetry there is a polar tracking available in AutoCAD program The polar tracking makes drawing at specified angle easier Having selected rectangular Snap and Additional angle for dimetry polar tracking will be activated which is adapted to design drawings in angle dimetry During drawing in isometry ORTO mode should be turned off 39 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Active polar tracking mode H Drawing dimetry e Dimetry Polar tracking option is not available in IntelliCAD program That is why a cursorObliquity option is available in the command line This op tion is used to change an oblique angle of graphic cursor compatible with current angle of dimetry An angle of dimetry is specified in CAD Profi Op tion dialog page 18 During drawing pipes in dimetry in IntelliCAD a user should use ORTO mode which can be turned on or turned off by F8 key During drawing a pipe a user should Slope graphic cursor specify the next points The curso rObliquity option is available in the UR command line In order to select the i option a user should write letter O in the command line and press En ter An oblique angle of cursor will be changed If a designer wants to y gt restore normal
33. enter distance or segmentLength Dynamically L Specify length of segment lt 1000 000 gt 1000 3404 igl P1 1000 1000 1000 404 Note During dividing of numbered objects numbers are removed Therefore it is recommended to number objects after ending edition of installation 72 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Dividing many pipes Using Divide pipes ducts command a user can divide many pipes into sections Once the command has run a user should select an option Layer All Select byPipe These options make pipes ducts cable trays to be selected in a different way Select pipe or Layer All Select byPipe The Layer option is used to divide all objects lying on a given layer After choosing the option an object lying on a required layer should be selected Afterwards a user should specify the length of sections Since pipes ducts cable trays belonged to the given system or installation are lying on a specified layer the Layer option can be used to divide quickly all ob jects from a given installation e g a user can divide all ducts lying on 2DL_PRE_o layer The All command is used to divide all pipes ducts cable trays in a whole drawing After choosing the option the length of sections should be speci fied All objects including not visible currently on the screen
34. libraries symbols used during designing schemas and symbols used on architectural plans Many symbols can be used both on plans and on schemas Since the beginners can have problems with finding required sym bols the CP System gt Electrics commands gt Symbols all command is available in main menu In order to find a symbol it is recommended to use the Search button which displays a dialog with all currently available ele ments Particular symbols are grouped in thematic categories It is possible to sort the elements of libraries and to display them by norms Automatic sign A amp Others a w Switchgear controlgear and protecti EN 60617 7 2004 Architectural and topographical insta EN 60617 10 2002U E E Lighting H E EN 60417 1 2002U Measuring instruments C2 EN 60617 3 2003 Production and conversion of electric co CEN 60617 9 2002U E E Industrial automation and measureme ce EN 60617 11 2004 w Equipment for fire protection and fire H E EN 60617 8 2004 Alarm Installations EN 60617 6 2004 E E Installations H E EN 60417 6 2004 w Telecommunications 150 6790 1998 Grounding IS0 6790 4k 1997 Passive elements w E EN 60417 10 2002U Active elements EN 60617 4 2003 S E Semiconductor device a RR ER gt Diodes Semiconductor diode E E Transistors Light emitting diode LED Thyrtistors Temperature sensing diode S E Others Variable capacitance
35. necessary a user should do it by inserting needed fittings manually e Duct device and rectangular or round pipe duct both are inserted J at the same angle P2 P L A rectangular round or rectan Q gular round reducer is inserted depending on a form of both duct device and pipe duct 67 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Edition of fittings The 2D edit and info command is used to obtain information about pipes ducts cable trays and fittings in a drawing Once a user has run a command and specified a required fitting a dialog will be displayed in which all parameters and dimensions of a selected element are presented If a user selects a pipe duct cable tray he can change its length directly A direct change of the length of a pipe duct cable tray In order to change the length of a pipe duct cable tray a user should select the end of the object P1 and then specify a new point as the other end of the object P2 Ht Lengthening or shortening a pipe duct cable tray Except for a direct change of the length a user can lengthen or shorten pipes ducts cable trays Unlike direct change of the length during a lengthening or a shortening only the length of the pipe duct cable tray is changed while a position of the element is not changed During lengthening or shortening a user c
36. others S C S E Fire Safety Armchair Cabinet Couch tou Desk 2 Furniture and equipment Furniture Genera Armchair h Atmehair Comer case Couch tou Diop Tab Bookshelf Chair Comer case Couch tou Aimehair Cabinet Chai Dh Chest of drawers lt LB Comer case Dimensions Types data descriptions Length Width Height Levet Column Loudspeaker Search Cancel Current unit centimetres Symbols and marks This command enables a user to describe objects There are available level indicators marks of architectural woodwork as well as a label of rooms The Marks command is described more detailed in chapters about edi tion of schemas of installation see page 32 In architectural module this command works in the same way A user can create his own libraries with the use of the Add block to library command User s symbols are added automatically to a special li brary Working_symbols see page 111 83 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Mechanics Parts Mechanics CP System Mechanics can be used by designers during creating detailed drawings In CP System there is a extensive set of standardized elements that is es sential for every designer Most of CP System modules are intended for designers who create projects in architecture Because of
37. required fitting A miniature with all dimensions for selected fitting is displayed under a list of available fittings In order to enlarge the miniature a user should click a right mouse button on it A list with parameters of selected fitting is on the right side of the window A list of parameters consists of a few sections Marks or are used to open and close particular sections A description which explains in details Producer and type Elements selection from database the meaning of an active parameter is below the list A user can turn it on or Z Description off by means of Description option A user can select parameters from the databases or from lists 51 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings choosing a parameter from the databases BB supply ar selecting parameter from a list Pipes plan 2D a Duets rectangle Installation and drawing Duct D Bend E Elbow Type Duct Installation B Supply air gt Reducer Manufacturer and type Reducer rectangle round A Fuller AP Fuller bend cD Tee piece Product E Tee piece simple Dimensions amp Reducing tee piece 500 A E Tee piece rectangle round gt Cross Dimension B 00 Copy dimension by entering 2 points gt Cross simple Options Copy dimension by selecting a fitting gt Redu
38. select a required dimension he should mark a particular type on the list For some objects like distributors are available databases specifying all dimensions with exception of the length of connections every time can be different length of a connection Inserting these objects a user should spec ify essential dimensions on his own If a device that is not in a program databases must be inserted a user should select a parametrical object that is the most similar to an inserted device and select the Enable all dimensions option After a user has pressed the OK but ton the program will demand entering appropriate dimensions The dimen sions should be entered in a current unit m cm or mm Note It is impossible to check dimensions before inserting an object When a user specifies wrong data an object can be deformed It is also possible that an object will not be inserted in a An example of inserting of an object drawing with a too large flange Before a user inserts an object he can see an enlarged preview of it A user should click a right mouse button on the miniature of an object to see an enlarge view Wl Parameters Specify all parameters Parameter Value L H1 21 5 H 16 78 3 Al 24 3 A2 10 c 16 5 B 16 Right mouse button enlarging miniatures Cc 14 47 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Plans a
39. texts by the window of selection Other objects being inside a window of selection will not be removed Copied objects with invalid numbers Source objects Renumbering copied objects Edition of numbered pipes ducts cable trays and fittings Every command that make pipe duct cable tray to be divided into two separated elements causes the assigned numbers to them to be re moved Numbers are removed during inserting parametrical armature or duct devices in pipes or ducts some joining e g by means of tee pieces in the Divide pipes ducts command during removing symbols by means of the Remove symbols command 100 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Specifications Specifications The Specifications command enables a user to obtain various specifica tions of data To obtain specification easy and quickly a user can select one of prepared templates and direct printing In case of creating specifications in AutoCAD 2007 or higher or in Bricscad v8 x or higher the program bases on Unicode characters Thanks to this a user can obtain multilingual plots e g Russian Polish German and other texts can be placed on one specification Specifications created in previous releases of AutoCAD IntelliCAD program are compatible with codepage of a current language of CP System or operating system After the command ha
40. 0 LT 4 an P1 P2 400mm long closed shape Change of the length of shape for 500mm i e change of scale X 500 86 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Mechanics Steel shapes Steel shapes are inserted as blocks in CP System program Scale X for side views suits the lengths of shapes In case of cross sections the length of shape suits scale Z of block Therefore by changing scale X or scale Z a user can change the length of a shape inserted in a drawing e g using CAD command Properties In order to display the Properties in AutoCAD a user should click combina tion of Ctrl 1 buttons or select an appropriate command from main menu of AutoCAD The Properties command is in main menu Change in IntelliCAD The Properties is also displayed after double click a required object Properties bar Block Reference Block Reference Color E ByLayer E General Layer 2DH_OBP_WIL Color E ByLayer Linetype ByLayer Layer 2DH_OBP_WIL Linetype scale 1 Linetype ByLayer Plot style ByColor 7 i Lineweight a yyer Linetype scale 1 Hyperlink Plot style ByColor Lineweight ByLayer Position x 6545 3902 Hyperlink Position Y 1505 9667 E Geometry Position Z 0 E Insertion point 6 6183 2 4675 0 0000 Sake Scale 1 6 6183 Scale Z 1 2 4675 9 0000 Name 2hpn_stratos_z_025_1_6a_g0 Da Rotation 90 Block Unit Unitless 1 U
41. 2 C Double stand pump E WiolL E BF C Double stand pump hese e ILE 65 8 40BF Expand all ILE 80 8 42BF Collapse all IL E 80 9 48BF 21 145 IL E 100 5 21BF 234 12 IL E 100 5 268F 234 12 ILE 100 6 298F 234 12 ILE 100 8 33BF 27112 QiwiloPL Wilo IL 1450 rpm CiwiloL 2900 rpm Oi wilotPn 14501 Layers Object style v Axes Details hatch V Insert as block 7 Hidings Texts 7 With attributes View OE Enter all dimensions O Plan Info on website How to add new elements Enter all dimensions Stand pump Current unit centimetres Option of parametrical objects Layers eliminating layers that contain axes details hidings and others a user can specify a precision of drawing of parametrical objects Style of an object Parametrical objects can be inserted as blocks that contain attributes Thanks to this a user can edit technical parameters insert descriptions and create specifications automatically Parametrical objects can be inserted without attributes or as an exploded object 46 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Plans and sections Dimensions of objects Once a user has selected a view of a device a list containing sizes of de vices appears All dimensions are shown in a current unit If a user wants to
42. 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Specifications Printing data After pressing the Print button a dialog with options of printing is displayed Print Options Print setup Export Media HP LaserJet 3392 PCL 6 A Preview v P Preview B File HTML Format Direct to Options 4 First Page E Pages al ORange s Enter pages or rang ex 1 3 4 10 Pf TIFF Picture Rich Text Format RTF A Pinwriter TTY 5 Text Format Microsoft Excel Format a XML Format s Microsoft XPS Format Print A user can print data directly on a printer or export them to various formats xls txt rtf pdf html xml and many other During direct printing it is comfortably to display a final preview thanks to what making any corrects will be possible An interesting option is a possibil ity of sending the first page of specification on the other printer than the rest of pages This option can be used to print the first page consisting of logo of company on colour printer and the rest pages on a monochromatic printer gt gt i if VIR An SSB Ba ASAP Report data PROFI 1 cphs_850a Control valve 3 2 CPHS_872 Flanged ball valve 1 3 ophs_010a Pressure reducing valve 1 _4 ophs_008a Safety valve 1 5 CPHS_oo1 Stop valve 1 6 ophs 014a Swing check valve 1 D
43. 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Settings and interface of CP System Menu and toolbars Multisymbols Symbols DA Cross symbols Marks amp Delete symbols a Mirror symbols TE Pipes scheme 8 Pipes Ducts edit HRE Schemes 9 Plumbing objects scheme 7 Plumbing objects plan T Radiators g Parametrical objects 16 Parametrical armature Pipes plan ci Pipes sequence al Join pipes ca Divide pipes w 2D edit and info 64 Multisymbols E Symbols gt Marks TE Ducts scheme 8 Pipes Ducts edit 1 Duct devices Outlets NA Supply air centrals OE Ducts D Ducts sequence ca Join ducts ey Divide ducts w 2D edit and info Plumbing toolbar ae fom oe ITa goad Plumbing Multisymbols Symbols Cross symbols Marks Pipes schema Schemas Plumbing objects schema Plumbing objects plan Radiators Parametrical objects Parametrical armature Pipes plan Pipes sequence Air condition toolbar Noo ung mp a Multisymbols Symbols Marks Ducts schema Duct devices Outlets Supply air centrals Ducts plan Ducts sequence Mechanics toolbar Ba Steel shapes T b Q EV g Water supply devices e Mechanics Symbols hydraulics and pneumatics e Parts TE Lines hydraulics and pneumatics e Steel shapes Lines edit e Water supply devices of Marks e Symbols hydraulics and pneumat
44. 60 See eet eee ete ae eS A flex elbow Flex elbow is exported as a flex pipe with specified length in specifications A flex fuller Flex fuller is exported as a flex pipe with specified length in specifications 136 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Rectangular fittings an annex to specifications made in CP System A rectangular pipe L hi zN mi B E A rectangular duct fit C L A BI A rectangular truncated duct L ZT An elbow A2 t IF a t E A rectangular bend JT ane E R 4 Al A rectangular bend TYPE2 A2 A rectangular bend TYPE3 AQ TE Fir 4 A rectangular bend TYPE4 Ai 5 A2 R F ii r oa a B B A rectangular reducer A rectangular round reducer A fuller bend ee Fo HE Fy E A A2 ES wo IN A F K VAl lt A2 B2 m D _ A L amp 7 L E7 B B BLA A tee piece A tee piece simple A reducing tee piece A rectangular round tee piece NAS R A3 A3 aD3 ts e We As S A A 2 A A2 A2 B2 Ma LA a j o AE r A x A A cross A cross simple A reducing cross A rectangular round cross N AS A3 Ad ODS R Eea Ik ee A A2 A A w A a Eh k CE na I ODF A tee piece branch An internal cap An external cap A flange L rol fb mk A TI A rectangular coupling A2 R f
45. 81 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Architecture Architectural woodwork parametrical objects Architectural woodwork parametrical objects There are typical windows and doors in CP System It is also possible to insert elements on plans horizontal sections as well as in views of eleva tions or vertical sections In case of inserting windows on plans a user can specify the thickness of a wall Thanks to this windows are fitted to the thick ness of walls After inserting windows or doors in walls it is necessary to cut out manually redundant segments of walls using of the _TRIM command Walls will be corrected automatically in the future releases of CP System Windows and doors are parametrical objects for which specifying dimensions is possible Databases containing elements prepared on the base of norms and products of known companies are available for windows and doors During inserting parametrical objects a user can enter dimensions manually In order to do this he should mark the Enter all dimensions option before clicking the OK button A Doors windows x Windows Atticle S R BR n Don E Windows with sil intemal elongated a By dimensions of hole window Window double 120 120 50 50 G pea m Window double 150 150 50 50 Ter Te Window double 180 1800 50 50 Window double 210 20 50 50 T Window single for public building
46. AC Electrics Edition of schemas Distance Space P3 P4 W Pipes scheme gt ae x a E C Heating Selected pipes Supply Name Layer Line type Type of pipe E Return E Supply 2DH_PLS_s continuous DN50 E Heating water supply i Retun 2DH_PLS_r dashed DN5O Heating water retum Overflow pipe BB Air release E Filling drain E Supply of air devices I Return of air devices E Heat network supply W Heat network retum Safety pipe E Safety pipe drain left S E Steam condensate center Water O tight i Warm water E Cold water Y Draw by type of pipe E Circulation Soft water Mineral free water Rectangle snap Non it water i Garden water I Silted water Fuel E Refrigerating engineering D Ba cii Drawing settings v Show category User Current unit millimetres Cancel A user can add new definitions of pipes and installations CP System He can also create sets that consist of several pipes a Define new A designer can add his own types of pipes or installations For this purpose colour linetype and lineweight should be determined in an appropriate dialog New pipes are added automatically to the User category Copy pipes Copying selected pipe to the User category Edit pipe style Changing of parameters of pipes colour linetype etc Remove a pipe Removing of selected definitions of user s pipes When a user has removed an e
47. AD Profi Configuration program to configure AutoCAD IntelliCAD settings A user will be asked for choosing a required CAD program in main window of configuration program and then for pressing the Configure CAD button Configuration program will do suitable changes In case of using AutoCAD any changes will be done in a current AutoCAD profile A user can also create a new profile in AutoCAD program and later he can configure it using CAD Profi Configuration program This may be necessary e g during using a few various applications For more information about profiles see AutoCAD user s guide When a user has already finished the configuration he can start AutoCAD IntelliCAD using either its icon or its shortcut Additional main menu and toolbars will be activated in CAD program CP System program is developed as an application of AutoCAD program as well as the other solutions that base on IntelliCAD AutoCAD Architec tural Desktop AutoCAD Mechanical and other However additional components LTX for CP System or LT Extender make CP System to be used with AutoCAD LT W CP Configuration CAD CAD Profi program can work with various CAD programs Language Select appropriate CAD program to configure its setting in English order to be able to work with CAD Profi application press button Configure CAD The Following CAD programs have been detected Manufacturers libraries viewing Professional CAD s
48. ASAD PROFI e mail info cadprofi com http www cadprofi com CP System User s guide Copyright 2009 CAD Profi JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Contents Introduction About CAD Profi programs Important information about working in CP System Installation Installation of the program Installation of additional components Configuration of CP System to the CAD program Registration and activation of the program Settings and interface of CP System Menu and toolbars Commands repeating CPX CAD Profi Options HVAC Electrics Edition of schemas Multisymbols Symbols Cross symbols Marks Removing symbols and armature Mirroring symbols and armature Pipes Schematic pipes Pipes in isometric drawings Layers of pipes Defining and edition user s pipes or installations Specifying and changing type of pipe Libraries of typical schemas Plumbing objects schemas Plans and sections Parametrical objects Other commands to insert objects Pipes ducts cable trays and fittings Inserting 2D pipes ducts cable trays and fittings Drawing a sequence of 2D pipes ducts cable trays Joining pipes ducts cable trays Edition of fittings Dividing 2D pipes ducts cable trays ooun A 12 13 13 16 16 21 21 21 26 31 32 34 35 36 36 39 41 41 42 43 44 45 46 49 51 51 60 63 68 72 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030
49. LE Layers A user can use automatic managing of layers in CP System program by using of internal structure of layers It is very comfortable property because a user does not have to create layers and place objects on individual layers Layer structure of CP System program is used to automatic creating of speci fications numbering and in commands that make possible quick turning on or off layer groups e g quick hiding of all objects belonging to central heat ing system These commands recognize objects among others by layers That is why it is recommended to use system of automatic managing of layers If a user turns on the Extended layer name option CP System program will create separated layers for objects that belong to various installations Example symbols of plumbing are inserted on 2DH_SYM layer When a user has turned on Extended layer name option symbols inserted in pipes Supply Return etc will be on layers 2DH_SYM_s 2DH_SYM_r etc Using of the extended layers structure is necessary by creating separated specifications for individual kinds of installations e g Inlet Outlet Supply Return However a lot of layers will be created in a drawing in this case A user can turn off an automatic managing of layers in CP System If the Current layer option is active all objects will be inserted on a current layer that can be changed by a user If Fixed layer option is turn on all objects will be inserted on a f
50. a P 2 command he should specifies a pipe where the symbol will be in gt a serted P1 Pg fats or RY gt 2 CP System indicates the end of 7 2K the pipe which is a point of refer P1 Pit P2 N ence to set the distance P1 3 Next a user can specify the distance or specify a point P2 which sets a new point of reference P2 This point is set as a perpendicular pro jection of P2 point 4 When P2 point has been set a user should press ENTER 24 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas e Into many pipes thanks to this option a user can insert quickly a selected symbol in many pipes After choosing E this option it is necessary to select points P1 and P2 that will set line breaking of de manded lines This option works only if one element is selected Intelligent copying of symbols To make a designing quicker CP System program allows a designer to do an intelligent copying of symbols from a current drawing In order to copy symbols it is necessary to start the Multisymbols com mand and then select the Select symbols Pg option Program will hide a dialog and a user will be able to select copied symbols P1 P2 P3 Sym bols will be copied in his order as they were selected in a drawing It is pos sible to select the same symbol many times If a designer wants to finish
51. a unit is specified as mm 600 x 400 dimension object will be inserted in drawing unit cm 60 x 40 dimension object will be inserted in drawing unit m 0 6 x 0 4 dimension object will be inserted in drawing unit 16 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Settings and interface of CP System CAD Profi Options When a user designs projects on building plans he needs to check the unit of a source drawing The best way is to use the Distance _DIST command to measure the distance between two points for instance a door Depending on that distance a user needs to set unit of designing for CP System program There is also possibility of rescaling the whole building plans to fit the size of drawing to required scale For instance if a drawing had been drawn in cm a user can rescale it 10x and use mm to design in CP System Sometimes building plans are drawn for example at a scale of 1 50 CP System cannot work in a scale that is why a user has to rescale such draw ings to standard units mm cm or m The Set the global linetype scale factor for unit variable _Itscale com mand activates automatic setting of density of dotted or dashed lines Den sity of lines is appropriate to CP System installation projects architectural drawings etc In case of mechanic projects a user is recommended to spec ify optimal linetype scale by himself for instance using _LTSCA
52. a user can also specify a type of a symbol of a cross section Z Z or without a symbol as well as a point of inserting the beginning the axis the end ae i or N N Without a symbol 58 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Defining user s fittings When designing a user sometimes needs to use untypical fittings In this case he E Elements 2 Z should define his own fittings CP System 1 Flange H H A Fuller will consider them during numbering as P Fuler bend well as creating specifications gt Reducer aia sg pran E Reducer rectangle round In order to define an additional fitting it is gt Reducing cross necessary to draw it and to start the E Reducing tee piece Pipes Ducts Cable trays command The B Teepiece is selecting User objects defin ie aha next step IS se ec g J c Tee piece branch Ing option It is necessary to specify a new d Tee piece rectangle round name for a new fitting A user can also k User obiects defining Ducts round v enter other parameters e g manufacturer or type After a user has pressed the OK button he should select objects which a new fitting consists of and specify a base point If a given fitting is often used it can be add to the libraries of the program with the use of a Add blocks to the libraries command see pa
53. ad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Then he must press right mouse button to display context menu A selected dimension can be copied either by specifying two points or by selecting a fitting When Copy dimension by selecting a fitting option is used a user has to select a fitting to copy dimension from If the selected fitting does not have a given dimension an appropriate message is displayed in the command line and a user can continue selecting fittings For example a tee piece does not have dimension E so that if a reducer was selected in a dialog before a dialog was hidden a dimension E was to be copied and a tee piece was selected a message Cannot copy a dimension E from selected fitting will be displayed and a user will be able to continue selecting or to finish command by pressing ESC Parameters of fittings Installation and drawing Installation selecting of an installation or a system Installation can specify a flowed factor e g fuel oil gas milk or system supply return supply air exhaust air etc In the list of available installa Installation and drawing tions there are the most often H Fresh ai recycled z Type Beny Supply air used types of installations If a a Exhaust a roducer an e it user wants to select other types a E og a of installation he should select Recirculation the Oth
54. an set the length by specifying a point P2 specify completely new length specify the change of the length in percentages Us specify increase of the length t o ll After a user has selected a command he should select a pipe duct cable tray To specify a new length a user should select the changeLength command in the command line Then he should enter a required value The length can also be set by selecting any point P2 Alerts and options displayed in a command line Specify CAD Profi fitting Specify point or changeLength Edit L Specify point or enter new length or Delta Percent 5000 The Delta option indicates change of increase of the length of an object In case of entering a negative value the object will be shortened 68 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings The Percent option indicates change of the length of an object in percent ages in relation to a current length If a user enters value 200 the length will be doubled but if he enters value 50 the length will be reduced by half The Edit option enables a user to change a cross section and other P1 parameters After a user has se c gt lected the Edit option a dialog with all current parameters of pipe duct cable tray will be dis An example of changing of diameter of a played pipe Edition of fittings To edit fitting
55. ass 3 4 denotes a mass of a given element 1K Welded square structural tubing Cold formed welded structural hollow sect E IA Welded square structural tubing Cold formed welded structural hollow sect E Additional parameters t Ww Attributes Name Data Welded square structural tubing Number Equipment Quantity Weight Characteristics Order No Producttype Article 25x25 Producer EN 10219 22000 Other lt Options Show all attributes C Draw frame C Rotate text Leac Text style normal or isometric O Normal Isometric Tent size Scale 1 50 Height 1 O Isometric tumed round Sa Additional parameters t Up Dom Attributes Name Number Equipment Quantity Weight Characteristics Order No Producttype Article Producer Other Material Data Welded square structural tubin aluminum 25x25 Aluminum Options Z Show all attributes C Rotate text Text style normal or isometric O Noma Isometric Save attributes Insert text Cancel C Draw frame Leader Text size Scale 1 50 Height fr O Isometric tumed round pisai Changing parameters of steel shape for aluminum shape The specification of shapes can be created with the use of the Specification command Mechanics steel profiles should be selected as a type of a specification A user can create summary specificati
56. ate the program without losing data that he saved by himself During updating standard databases are overwritten or placed in the other folder and user s databases remain untouched A user can save his data in the UserData folder This folder is placed in main folder of the program e g C CadProfi If a user wants to save all changes in user s databases he should archive all the UserData folder When a user re installs CP System or transfers it to the other computer he can copy content of the UserData folder to new installation It is also possible to copy UserData data in one company JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Installation Installation of the program Installation In order to install CP System program a user needs to have rights either of advanced user or administrator Once the application has been installed it can be used by a user with limitations It is important that a user has rights to save in a folder where the program is installed Installation of the program After inserting the CD to the CD ROM driver a user will see a window where he can either start an installation of the program or choose the other options If the window does not appear it will mean that a function of an automatic playing was turned off for a CD ROM driver Then a user should start the autorun exe program placed in the Start folder on the CD ROM driver Once an ins
57. be able to see the state of currently processed command 7 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Introduction Important information about working in CP System Expansion of libraries and catalogues of manufacturers A user can expand libraries of symbols and objects of CP System Once the program has been installed a user can install new libraries of manu facturers e g the ones that have been created after buying CP System Both user s and manufacturers libraries are stored in folder Producers This folder is placed in main folder of the program e g C CadProfi lf a user wants to save any changes that were done in manufacturers librar ies as well as in his own symbols and objects libraries he should ar chive all or only selected libraries from the folder Producers After possible re installing of the CP System or during transferring it to the other computer a user can transfer content of the Producers folder to new installation There is also possible to copy libraries in one company User s database folder UserData A user can define various parameters or expand standard databases He also can for instance specify additional kinds of installations and pipes or ducts define additional parameters for objects e g price colour cur rency etc Standard databases were separated from user s ones in CP System Thanks to that a user can upd
58. bles grouped in categories A user should fill tables by edition of their attributes with the use of the _DDATTE command Categories of tables Tables typical drawing tables Specifications tables used to make specifications in a drawing Legends typical legends that contain recommended layers of pipes for plumbing and air conditioning installations User s empty tables that can be defined by a user User s tables should be created in Tab_usergb1 dwg to Tab_usergb5 dwg files gb denotes language version of the program e g for English gb Files of user s tables are stored in folder C CadProfi xx Blocks Tables_gb C CadProfi xx it is a default folder of CP System After creating tables a user should create slides for them The slides should be saved in the Tab_usergb1 sld to Tab_usergb5 sld files in folder C CadProfi xx Slides The CAD command _MSLIDE is used to create slides Note Legends and specifications can be also created by means of a Specification Wizard 96 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Numbering of objects Numbering of objects Numbering system enables a user to assign numbers to symbols and objects created by CP System Objects data as well as numbers are used in de scriptions and specifications During an automatic numbering a separated numbering for various installa tions and objects is used Examp
59. both diameters and distance of axes of reducer because these parameters must be compatible with diameters and position of pipes ducts cable trays On the other hand length of a reducer and dimen sions E and F can be changed It is also possible to join pipes ducts cable trays and fittings as well as joining fittings If a fitting is one of the selected objects to join it can happen that a fitting has too little room to be inserted A message is displayed in such case but a user can still insert a fitting It must be moved e g by means of CAD command _MOVE subsequently Example e Step 1 pipes are drawn l es ff ff ff 7 fof ff ff fF 7 7 FP e Step 2 pipes are being joined by using appropriate fittings reducers fullers tee pieces SS SES 63 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings The rules of joining One pipe duct cable tray A cap a flange a muff or a nipple is inserted and a pipe duct cable tray may be lengthen shorten Two three or four coaxial pipes ducts cable trays with the same diameters No fitting is inserted Two coaxial pipes ducts cable trays with different diameters inserted at the same angle A symmetrical reducer is inserted By inserting a reducer length of a first selected pipe duct cable tray is not changed Je
60. ces catalogue numbers dimensions etc To edit a user should run a command Add blocks to library and press a button Library editing V Add standard attributes Edition data of a library Add marker of the base poini A user should specify in dialog e Name name of an object that will be displayed in a dialog as well as in specifications e Short name up to 10 15 characters It is displayed below miniatures of blocks in dialogs e Category name of category in which a device will be available e Catalogue number if added objects present a specific device a user can enter a catalogue number that will be taken into account in specifica tions e Dimensions length width height Dimensions can be entered or measured In order to measure e g the length a user should select the most convenient view and then press the button Length 530 A dialog will be closed and a block with a selected view will be inserted in a drawing Two points should be selected distance between them deter mines a value of length After selecting the second point dialog will be re displayed The height of a device can be measured on front view or on 3D model Dimensions are not available for symbols Possibility of scaling of a block during inserting in a drawing Parametri cal blocks can be added to CP System When inserting these blocks in a drawing a user can specify dimensions of a device by himself An
61. cify extra parameters They will be available stored in attributes so they are for all CAD Profi objects invisible in standard commands of AutoCAD IntelliCAD used to edit attributes e x D e f additional parameters for CP Hews System objects were filled then ence Color these data would be stored even in case of removing definitions of these parameters However they will not be taken into account in specifications e When defining parameters CP System assigns automatic identi fiers to them After removing a given parameter and adding it again to the program other iden tifier will be assigned to it Be cause of it a user should avoid redundant operations of removing or adding parameters e Definitions of removed parameters can be retrieved at any time If an object has parameters that are not on the list then the Recover parame ters button B is visible After pressing this button identifiers of re trieved parameters will occur A user should enter required names of pa rameters in place of identifiers 95 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Drawing frames and tables Drawing frames and tables Both a frame and a table are important elements of every drawing The Frames and tables command allows a user to insert typical frames and tables easy There are available horizontal and vertical frames as well as ta
62. cing cross Cancel gt Cross rectangle round Tee piece branch Width and height fit Duct truncated Continue with a pipe Elements 2 Z D Cap 1 Flange amp Coupling 4 User objects defining Ducts round Manufacturer Type Installation fit HOSA Join object Enlarging right mouse button Dimension A Specify dimension A v Description Current unit millimetres Copy dimensions gt Cancel A dialog with a selected rectangular duct Copying dimensions During drawing a user often needs to insert elements similar to the elements that have already been inserted in a drawing In this case copying dimen sions by using button Copy dimensions is the easiest way to do this Once a user has pressed the button he must specify a required fitting It is impor tant not to specify fittings with completely different parameters than an ele ment selected in a dialog because ambiguity of interpretation of data can occur For example if an elbow is selected in a dialog and during copying dimen sions a reducer will be specified then CP System will not be able to specify the radius or the angle of the elbow because a reducer does not have such parameters It is also possible to copy single dimensions To do that a user must click an appropriate field in the list of parameters to activate it e g a diameter D 52 JL Systems Group Slottsmollan 302 31 Halmst
63. command In this command there are various ob jects to built on pipes e g in line pumps e Block pump of X company Unless the company is in manufacturers libraries a user should look for it in the Parametrical objects command because there are objects which are not inserted in pipes e g block pumps or pumps with foundation board e During edition of schemas symbols of pumps are available in the Sym bols as well as Multisymbols commands 45 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Plans and sections Parametrical objects In Parametrical objects Parametrical armature Switchgears Steel shapes commands and others there are available objects for which a user can define many dimensions A flange valve is an example for which a user should define both length width height and dimensions of flanges and other Databases containing standardized elements as well as elements prepared on the base of types of some manufacturers are available for every paramet rical object Inserting parametrical objects a user can enter dimensions manually That is why parametrical objects can be used for any devices even for these that are not in standard databases of CP System program W Parametrical armature EO Amature _ Aricle Flanges E wioiLE w Condensation drains IL E 40 9 39 Pumps ILE 50 10 36 Ch Stand pump ILE 65 6 24 Oh Stand pump ILE 80 5 2
64. constructi Window double 240 2400 50 50 T Window double for public building construc a By dimensions of window w A View C Doors Window double 270 z0 50 s50 1 Parameters Specify all parameters Parameter Value Info on website How to add new elements Enter all dimensions Window double Current unit milimetres Hep J seach J coca f oK During inserting a window a user should specify the point of inserting P1 centre of a window as well as the second point to specify an angle of insert ing P2 After the window or the door has been inserted it is necessary to remove redundant parts of walls using _TRIM command P Pe A view after inserting the window A final view of a wall 82 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Architecture Furniture equipment Furniture equipment The Furniture and equipment command enables a user to select and insert furniture plumbing objects etc A user can specify any dimensions or select types from available databases for most objects After a user has inserted objects in the project he can specify their parameters manufacturer type etc These data will be considered during creating specifications Detailed description of work with objects is discussed on page 46 W Furniture and fittings Bathroom kitchen fittings w Bathroom kitchen fittings
65. cross oD 004 s E 132 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Round fittings Z aD O 4P Z GI A cross Z Z ne io EDS a L3 paan A cross with reducer TNA joo A reducing cross A tee piece branch A view for tee piece branch Z Z 133 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Round fittings A tee piece branch oblique aD An internal cap eL An external cap 9 D A flange During inserting flanges a user can turn off considering them in specifica tions A muff 134 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Round fittings L kt A nipple i i gD mi ae A round coupling T A round coupler is used to join round D pipes to rectangle devices or pipes 2E L L A formed saddle gore A pressed saddle p D 2 ep ra I1 ss A taper saddle i f oD 135 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Flex pipes Flex pipes L A flex pipe e Flex air conditioning pipe aaa e Protective pipe in Electrics
66. ct with the CAD Profi Server Policy of keeping privacy of users during on line update To save user s privacy the program neither send nor collect any user s data The only elements which are sent e A serial and an ID number of CAD Profi program e information about installed components of CAD Profi program These data are necessary to specify availability of updates for a computer They are also necessary to check rights to download updates as part of a program subscription with a given serial number 20 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas HVAC Electrics Edition of schemas A user can create any installations schemas in CP System program Design ing of schemas a user can use intelligent symbols pipes and functions that are used to describe drawings and to create specifications All CP System symbols have specified properties and that is why they be have in an intelligent way for instance match automatically an inserting angle to a pipe and break automatically a pipe in a connection points Sym bols can be described automatically as well as can be used to automatic creation of specifications Multisymbols Symbols and Marks commands are used to insert symbols into drawings Multisymbols F Multisymbols command allows a user to select many symbols that will be inserted into a drawing at the same time Symbols are gr
67. diode varz Symbols Tunnel diode Esaki Electrodes gt Breakdown diode unidirectional E Vacuum tubes w et Breakdown diode bidirectional Y lt f E lt i gt C Sort C Show noms CO Sot Show norms Symbols are also available in Multisymbols Marks Cross symbols com mands These commands enable a user to insert many symbols at once automatic inserting symbols in cross of lines as well as inserting marks Some marks are filled automatically on the base of properties of described objects 74 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Electric schemas All properties of symbols and all options of particular commands were de scribed in details in previous chapters e Multisymbols page 21 We recommend to familiarize with the proper ties of symbols ways of inserting many symbols inserting symbols in lines inserting a symbol in many lines and with an intelligent copying symbols e Symbols page 26 In this chapter there are described options of symbols inserting symbols inserting symbols in lines inserting symbols repeatedly It was also explained how to insert symbols at a constant angle multivariant symbols or symbols containing texts e Cross symbols page 31 Automatic inserting symbols in a cross of two lines Using this option a user can insert easily thyristors switchers transistors etc 1 gt PI e Ma
68. ds X X A designer should enter the distance of joining from a base point of selected symbol Base point 0 5 0 5 Notes There are additional parameters in a dialog These parameters are grayed because they are reserved only to develop the program as well as for manu facturers of devices that prepare new libraries to CP System 117 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Edition of data in libraries List of 2D fittings The most often rectangular steel air conditioning fittings and ducts are joined by means of flanges Air conditioning fittings and ducts are drawn on the base of EN as well as DIN norms in CP System According to these norms flanges do not have to be displayed on a drawing Thanks to this pipes ducts and fittings from CP System program can be used in any projects of installa tions that use various technologies materials and ways of joining e g instal lations with steel pipes ducts plastic installations etc There should be specified kind or type or technology of used air condi tioning ducts in a project An appropriate note should be placed e g in a describing part It is possible to insert flanges by means of an appropriate command of CP System if necessary A designer is also responsible for decision whether flanges inserted in a drawing are to be taken into account in specifications or not Rectangular eleme
69. e Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Marks The command allows to insert various marks that are used by designing installations During inserting some marks a list that consist of values suitable for a given symbol occurs for example for a symbol of mark of pipe a list that contains standard sizes of pipes occurs W Line diameter Article Value 5 O Marks of pipes Routing designation In order to change texts that are contained in symbols of marks a user should use a command of AutoCAD IntelliCAD Attributes edition _DDATTE or CP System command Attributes and descriptions see page 92 Edit Attributes Block CPHS_2551S0 Tag Prompt Value VAL Value I DN VAL PRE 25 NAME Name Routing designatial GROUP Group NUMBER Number PRODUCER Producer ARTICLE Article PRODUCT TYPE Product type ORDER NO Order No CHARACTER Characteristics DN DN PN PN TEMPERATURE Temperature FLOW Flow POWER Power rating VOLTAGE Voltage WEIGHT Weight OTHER Other a j Value 25 OK Cancel Help 32 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Automatic marks In CP System there are symbols which can be filled automatically These symbols copy data from described objects That Z Leader is why during automatic inserting marks a designer sho
70. e aime ET onts Aor i changed for icad_org Isp Svein S himord cl This file will be loaded patterns SM hicalsrd dil S Icadauth dl automatically by CP Sample Mhieosatrd dll 3 Icadauto dll System application 11 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Installation Registration and activation of the program If a user specifies these settings he should close IntelliCAD program The next run of IntelliCAD will also load CP System automatically Notes about using AutoCAD LT Assistant Using CAD Profi programs in AutoCAD LT it is strongly recommended to close the Assistant Registration and activation of the program During starting of CAD Profi program dialog Registration of the applica tion is displayed A user can either activate the program or press the Close button to start the program Dialog Registration of the application is being displayed until the activation code is entered A user has to enter the code within 30 days Otherwise CAD Profi program will not be run any more Wl Registration of application activation of licence If a user has connection to EEE P E the Internet he can activate a elt en noir sorters ete eee tet i you will receive codes which must be written down to the fields of particular modules the program automatically by using the Activate by the Non egistered modules will work for 29 more days Active licences In
71. ective and flexible pipes and much more elements are available They are drawn by means of lines with the same colour but lying on different layers In order to change a type of cable a layer of this element must be changed Cables can be described automatically with the use of special symbols of marks The Cable trays schematic command enables a user to define any types of cable trays The newly defined elements are added to the User category A user can copy and edit their style It is impossible to edit a style of original cable trays If their definition must be changed they must be copied to User category and edited in any way by the user Commands Cable trays as well as Cable trays sequence enable a user to draw 2D cable trays Drawing of them is very similar to drawing plumbing pipes or air conditioning ducts see page 51 It is possible to specify any dimensions for drawn cable trays or to select them from databases Note Although cable trays cable ladders floor or plastic trays and other 2D elements look similarly on plans joining automatically elements of various systems is not possible gt t X amp E E O Curent Selected pipes M Gener i Layer Line ype 2DE_PLS_N Continuous 2DEPLSF Dashed 2DEPLSO Continuous E Plasti Protective and flexible pipes Sets of pipes Olet Space 20 center O tight Drawing settings Rectangle snap
72. ed files of s d slides in which are miniatures previews displayed in dialogs The Add blocks to library command automates the process of preparing all files which CAD library consists of and adds them to a special Working folder objects or Working folder symbols library In order to add blocks saved in dwg or dxf files to CP System a user should start the Add blocks to library command in a new drawing and then specify a source folder A button enables a user to select a folder on a disk If a current drawing is not empty a user can add a block that consists of ele ments in a drawing For a created block a user should also specified the name of a file in which the block will be saved By default blocks are added to library Working folder objects folder Work ing_folder on a disk If a user marks an option Add to symbols folder blocks will be added to a library Working folder symbols folder Work ing_symbols on a disk Names of target symbols can be changed only in special version of the program that is intended to create catalogues of manu facturers Add objects to library Select source of blocks and add them to selected library Source of blocks Objects from drawing Source folder D CadProf 6 05 Destination folder and blocks category Destination folder Add to symbols folder Category Heating Armatur Unit and scale of source blocks Specify unit of so
73. egistry This name can be obtained from a distributor of IntelliCAD program An exemplary entry for different versions of IntelliCAD e BricsCAD IntelliCAD RegICADKey Bricscad e ProgeCAD IntelliCAD RegICADKey Progecad Once a user has added the entry CAD Profi Configuration program will find given version of IntelliCAD and will make appropriate configurations Some distributions of IntelliCAD program are not compatible with a kernel of Intelli CAD Some problems can occur in these distributions by automatic configu ration of CP System and manual configuration is necessary There is also another possibility A user can specify settings in IntelliCAD program by himself To do this Choose the Options command from the main menu Tools and then activate tab Paths Files Add the path C CadProfi xx or other depend ing on a folder where CP System was installed in the position Menus Options General Paths Files Display Crosshairs Snapping User Paths Location Fonts D MntelliCAD_4 Prem Fonts Help D lntelliC4D_4_Prem Help Xrefs C Documents and Settings Adam Moje doku Menus C ACadprofiD InteliCAD_4_ Prem Hatch patterns D MinteliC4D_4 Prem Patterns D InteliCAD_ s fie System Files File Log file icad log Template icad dwa Alternate font txt Font mapping icad fp Browse 2 Anuluj If icad lsp file is in a folder where IntelliCAD is in stalled its name should be m
74. em using by AutoCAD IntelliCAD programs e Layers A user can set an automatic managing of layers to unchecked in the CP System settings However it is not recommended because some objects properties depend on layers For instance when a user makes specifica tions he can choose automatically objects from given module e g elec trics symbols If automatic managing of layers is unchecked a command will not be able to identify symbols of a given module Plot styles that specify optimal lineweights on layout are added to CP System These styles are matched to automatic layers structure JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Introduction Important information about working in CP System Toolbars In programs AutoCAD IntelliCAD a user can adapt both menus and tool bars Using CAD Profi Configuration program he can attach and detach CP System to or from the CAD application When a user attaches an ap plication to the program a standard CP System menu and toolbars are loaded At the same time any changes made in toolbars and menus will be overwritten Specification print preview A user can create specifications and professional plots in CP System He can save a print preview in pdf files or in his own format in files with LL extensions To browse LL files a user can use LLview13 exe file which is placed on the disk in main CP System folder e g C CadProfi xx
75. er Edit item Selecting this item causes the dialog with all defined types of installations to be displayed A user can specify an additional types of installations After se lecting the Add button a dialog will be displayed where a name and a style of added instal lation should be specified The style of an installation includes definitions of colour linetype and lineweight Defining installations see page 41 Type Other Edit W Select installation e m S O Supply air E Supply air W Supply air 1 W Supply air 2 E Supply air Fresh air I Fresh air d E Fresh air r W Supply air Copy W Supply air Add to favourites Exhaust air Add a o Others 53 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Type for some fittings a user can select a type A selected type of a fitting with dimensions is displayed on a preview Installation and drawing Installation E Fresh air recycled Bend x Producer and type Bend TYPE2 Producer Bend TYPES Bend TYPE4 Tyne Examples of typed fittings e Rectangular bends Bend Bend TYPE2 Bend TYPE3 Bend TYPE4 JUU e Round elbows Elbow Two segment elbow Segmented elbow and Segmented elbow with revisory door W Pi
76. er can select many objects during removing but CP System will remove only these symbols which are treated as armature views of valves pumps that were inserted in 2D pipes etc In order to remove symbols a user should start the command and then select symbols P1 P2 P3 The program will be removing symbols until a user press the Enter or the Esc button An additional options for removing are available in command line restoring symbols Specify a symbol to delete or Multiple Undo When a designer has chosen the Multiple button M option he should select required symbols P5 P6 and press the Enter button During selec tion he can select other objects e g pipes etc All elements which are not symbols or armature will not be removed bas 34 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Mirroring symbols and armature During edition of schemas or plans a user often has to mirror a direction of inserting symbols He can use the Mirror symbols command to do that quickly After starting the command it is necessary to select a required symbol Spe cial markers are displayed around the selected symbol To mirror a selected symbol a designer should click an appropriate marker When the symbol has been mirrored a next symbol can be selected The operation ends when Enter or Esc button is
77. er can specify all parameters of a drawn sequence WK Pipes plan 2D Ducts rectangle Installation and drawing Installation B Supply air Reference edge Axis Pipes flex Offset 5 0 Producer and type Elbow parameters Producer Radius 75 1 5 Product Dimensions Radius as a multiplier of width v Diameter D Type Elbow Mi Options Limit max anal Two segment elbow Installation fit Segmented elbow Diameter Fit Dimension E 0 Join object Dimension F 0 Reference edge Specify reference edge Description v Always show dialog Help l Cancel Current unit centimetres Subsequent running a command makes a user to begin drawing with current settings or to select an option Settings It allows to display dialog with all parameters of a drawn sequence The S letter should be entered in the com mand line and the Enter key should be pressed to run the dialog lt x Settings Supply air 4 50 B 50 Axis Distance 0 ecify first point or Settings Ready 391 24890584 21 72716494 0 00000001 2DL_PRE_i ByLayer ByLayer Standard Stand Parameters of a pipe duct cable tray are placed in the right part of a dialog The meaning of all parameters is the same as in Pipes Ducts Cable trays commands 60 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts
78. ertical dimensions of devices has to be kept on plots Because of that the program sets automatically appropriate size of symbols and disables possibility to change it An angle of rotation If the Angle option is active a symbol will be in serted with a specific angle If the Rotate option is active it will be possible to rotate a symbol during inserting it in a drawing look page 23 Angle and Rotate options are switched for many symbols by the program For instance Rotate option is set for symbol of a pump Thanks to that during inserting of the symbol it is possible to specify a direction of supply of a pump e Mirror this option allows a user to insert a mirror image of a symbol After a user has marked the Mirror X or Y option a preview of a selected symbol is updating systematically After turning on the mirror X or Y some texts in preview are displayed backwards or upside down In spite of that preview during inserting in a drawing texts are corrected auto matically see additional information about attributes at page 30 Isometry designing axonometric drawings CP System makes suitable transformation of inserted symbols Symbols are given a slope that suit to a current angle of isometry When a designer has marked the Isometry option meaning of others op tions related to rotating and mirroring is changed An angle of isometry is a default angle of inserting symbols This angle is specified in CAD Profi Op tions dial
79. es The Attributes and descriptions command enables a user to edit attributes and place them in a drawing as a text Attributes are also used during creating specifications It is possible to edit only objects created by CP System After a user has run a command and select a required object a dialog is displayed in which par ticular attributes can be edited The Save attributes button saves data and ends the command The Insert text button also saves data and allows to insert selected texts into drawing W Flanged ball valve lba Additional parameters Attributes Name Number 23 Group Weight Voltage Power rating Flow Temperature PN DN Characteristics Order No Product type Article Producer Other Options Text size 7 Show all attributes Draw frame Scale 1 100 Rotate text Height 2 Text style normal or isometric Normal O Isometric O Isometric turned round Cancel Save attributes Insert text In order to insert one line of a text a user should select highlight a required attribute However in order to insert a few lines of a text a user should se lect all required attributes During selecting a designer should click on names of attributes and keep the Shift or Ctrl buttons pressed The text is inserted in the same order as in the dialog omitting empty lines The Up Down buttons enable a user to organize the list Organizing the list does not c
80. es hatching etc Additional information about creating drawings are available in the Pipes chapter page 36 as well as in the Attrib gt utes and descriptions chapter page 92 Automatic isometric view User s symbol utomatic isometric vie Inserting symbols A designer can insert symbols in any point or in existing pipes When a user has selected a symbol and specified its options he should press the Insert symbol button to insert the symbol in a drawing It is also possible to insert repeatedly a selected sym pE Insert symbol V bol In order to do that a user should press the button Insert symbol and choose the Insert repeatedly option To finish Insert repeatedly the operation Esc button must be pressed All symbols which are in a library have specified properties that make a de signing easier For example e symbol of a stop valve can be inserted in a pipe with automatic fitting an angle and breaking a pipe e symbol of clung temperature sensor can be inserted in a pipe but will not break a pipe e some symbols do not have possibilities to fit to a pipe e symbols with visible texts attributes display additional dialog that is used to edit attributes Inserting symbols in pipes When a user wants to insert a symbol in a pipe he should specify P1 point on a pipe or any line If Rotate option is active a designer should specify the second point to specify an angle of inserted symbol An angle of sy
81. es to rectangle devices or pipes 127 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Round fittings Round fittings L A round pipe e Round air conditioning duct e Pipe gD e Protective pipe in Electrics i as View Z or Z Co rectangular pipe duct Duct Z Z is exported as 2D Z pipe duct in specifications Y L r A round duct fit The length of fitting element is ex ported with 10 extra length in speci fications es A round truncated duct A truncated duct on one or both ends is only used in drawings during at taching to other ducts or objects at specified angle In specifications the truncated duct is exported as 2D duct which a total length including cuts l 4 128 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Round fittings Endings of fittings Round fittings of air conditioning instal lations have nipple endings on which pipes can be put round ducts A user can also select muff ending that enables a user to put directly a fitting on other fitting Notes about E and F dimsensions For all fittings when E gt 0 and or F gt 0 do muff ending If E 0 and or F 0 do standard long nipple ending A round elbow Real fitting with nipple endi
82. et scale of drawings either during printing or when he works in paper space It is necessary to enter scale in some commands The most often this scale is used to specify an appropriate size of texts Linetype scale A user can design in various units mm cm m in CP System If he wants to change linetype scale CP System will change automatically a global scale factor A default global scale factor is 99 9 for designing in mm 9 99 in cm and 0 0999 in m Default linetype scale is appropriate for building projects as well as projects of installations whereas it is often necessary to change linetype scale for mechanical projects If a global scale factor is 1 0 in saved drawing CP System will change it for one of default values when a drawing is open A user should set any linetype scale other than 1 0 or default values by himself to make CP System not to change a global scale factor Changing of linetype scale is done by the command _LTSCALE JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Introduction Important information about working in CP System Once a command has been started a user should enter a required value e g 5 This value will be correct e g for most mechanical drawings drawn in mm Here is an example of changing of linetype scale Command _ltscale Enter new linetype scale factor lt 99 9000 gt 5 During starting some com EHEZ mands in mechanical In
83. ew with high head mso Countersunk Hat niob bots with cross recess M60 0 Slotted raised countersunk head screws mso Countersunk raised head screws with type H orZcrossr CM 10 0 O Slotted countersunk flat head screws Gmi20 O Round head niob bolts Gmie0 O Round head niob bolts M200 C Eye bolts threaded up to the head style 1 M240 O Eye bolts threaded up to the head style 2 O Eye bolts threaded up to the head style 3 O Eye bolts style 1 M Cun hatha ahin 9 lt OSot C Show noms Layers Object style Axes Z Details hatch Z Insert as block E Hidings Texts Z With attributes View OD O Hiding Info on website How to add new elements Enter all dimensions Hexagon head bol Product grade A and B Current urit milimetres Cancel Ok 84 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Mechanics Parts If a user specifies dimensions by himself then the program does not check whether they are correct so it s possible that a deformed object will be inserted 1A Parameters Specify all parameters Parameter Value L A Al B Cancel Contents of a catalogue can be looked through by types of elements or norms Many objects from the Parts command require man ual specifying one or more dimensions In this case a dialog is displayed in which a user should enter neces sary dimens
84. example of this object is bathtub One block presenting a bathtub can be inserted with the various lengths e g 170 or 200 cm Before inserting blocks a user should check out appropriate options in a column Fix XYZ in order to make specifying dimensions to be possible This option is not available for symbols 115 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Extending contents of the program Edition of data in libraries e Armature a user can specify in this column whether a given view e g 2D can be treated as an armature or not Armature can be inserted in 2D pipes ducts in CP System To do this properly a block has to be prepared in special manner Blocks of armature have to have a base point on the left side this is a first point of joining of a pipe The second point of joining of a pipe is specified by the length that should be entered in the Length original field Base point The length or 116 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Extending contents of the program Edition of data in libraries Edition of data of symbols For symbols library a user can specify additional properties e Break X X if the Break option is turned on a symbol will be inserted in a pipe with automatic breaking in points of joining Points of joining are specified in fiel
85. f devices CP Manufacturers is included in CP System program e CP Symbols it is a program containing complete libraries of sym bols for various branches as well as basic commands supporting sche mas edition Available modules HVAC Electrics Mechanics and Architecture CP System a comprehensive application that supports computer designing of installations There are available two basic modules HVAC and Electrics in which a designer can create any sche mas plans and sections The following modules are also available Architecture it contains elements that support creating of architec tural projects Mechanics it contains an extensive set of standardized elements used in mechanical and structural projects CAD Profi programs can work as applications for various CAD programs It means that CAD program is understood as AutoCAD or IntelliCAD program in this manual Many commands in these programs work similarly If there are any differences it is described in details CAD Profi Programs can cooperate with the following CAD programs AutoCAD from 2000 version e AutoCAD LT from 2000 version Most IntelliCAD distributions from 4 0 version in AutoCAD LT there is necessary to install additionally LTX or LT Extender program JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Introduction Important informatio
86. fixed angle of inserting e Connection points for symbols that have a fixed angle of inserting are fitted to vertical and horizontal pipes 29 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Using of multivariant symbols Appearance of some symbols should be different depending on an angle of inserting Such symbols have got prepared variants in CP System Inserting these symbols at various angles the program selects automatically appro priate variant of a symbol Example during inserting a D 90 angle symbol of thermometer in a vertical pipe an angle 90 or in horizontal pipe an angle 0 various variants of a sym P D bol are chosen o angle real Note During inserting a basic variant of a symbol is visible When an angle has been specified an appropriate variant of symbol is selected automatically Symbols including texts visible attributes For most symbols that include texts visible attributes CP System program sets automatically an angle of the texts Thanks to that texts are always displayed correctly Ways of configuring texts e Without fitting texts can be inserted at any angle e A fixed angle 0 e Anangle 0 or 90 If a symbol is introduced at a 90 angle text will also be rotated at an angle of 90 In other cases an angle of a text is 0 e Automatic angle from 30 to 120
87. from Electrics are drawn by means of flex pipes and flex fittings However flex fittings are treated as flex pipes so in specifications all flex elements are treated as flex pipes with specified length Creating specifications of 2D fittings Pipes ducts cable trays In order to take into account the length and amount of particular segments of pipes ducts cable trays in a specification this specification should be created with Length and Duct pes columns 118 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Edition of data in libraries In order to export only the total length of pipes ducts cable trays with speci fied cross section a user should not take into account columns Number Length and Duct pcs in specification There is amount of segments pipes ducts cable trays with given length in a column Duct pcs e g 6 segments 1800 mm long There is the length of elements in mm in a col umn Length e g 1800mm long segments System Name Article Ductpes Length Sum Supply air pressed saddle D2 160 D 200 L 200 a280Q 200 1 00 Supply air Duct D 160 1 918 0 92 Supply air Duct D 200 2 1800 3 60 Supply air Duct D 300 1 1675 1 68 Supply air Duct D 300 1 814 0 81 Supply air Duct D 300 1 904 0 90 Supply air Duct D 300 6 1800 10 80 Supply air Duct D 300 1 911 0 91 Supply air Duct D 300 1 1036 1 04 Supply air Elbow D 300 R 450 a 90
88. g is to be joined another fitting a user should specify the object inserted previously P1 a Most fittings e g elbows tee pieces crosses reducers fullers are joined closer end of an element P3 For some fittings e g elbows tee pieces a user should specify a point P3 as a direction of inserting b A part of fittings e g couplings are joined a side of a selected pipe duct cable trays 57 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings e Ifa fitting is to be inserted in any point a user should specify the insertion point the beginning of an object P1 and then a second point the end of an object P2 or specify value of an angle P1 gt gt PIE PS For some fittings e g elbows tee pieces a user should specify a point P3 as a direction of inserting For a given type of fitting point P3 sometimes is necessary sometimes not e g a reducer can be either symmetric or asym metric An asymmetric reducer requires point P3 to specify a direction of inserting while a symmetric one doesn t require P3 Fittings Z Z Z Z pipes ducts cable trays represent vertical segments along Z axis Only a symbol of a cross section is seen on plans for these objects That is why their length should be specified in a dialog before inserting them into a drawing For Z Z fittings
89. ge 111 An example of defining of rectangular tee piece branch A defined fitting consists of a rectangular duct and a bend The easiest way to draw a new fitting is to use the Ducts command Using this command a designer should insert a rectangular duct and a bend at an angle 90 In order to use a new fitting in various installations a user should move all elements on a layer 0 Thanks to that colour of a newly defined fitting and colour of an installation will be compatible Then Ducts command should be run and a user should select a position User objects defining A user should enter e g Tee piece TYPE X in a field Name and he also should set a required installation e g supply air oO The next step is selecting P2 elements that belong to a newly defined fitting P1 P2 and specify the base point of the fitting P3 During defining the fitting is inserted automatically on a layer belonging to the se P1 lected installation E 59 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Drawing a sequence of 2D pipes ducts cable trays The Pipes Ducts Cable trays sequence command enables a designer to draw many segments of pipes ducts cable trays with automatic inserting elbows or bends When a command is running first time a dialog will be displayed in which a us
90. ged For example if a drawing does not contain plumbing pipes an appropriate option is grayed All changes can be applied to all or selected pipes 42 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Libraries of typical schemas A user can use the Ready schemas command to insert typical fragments of schemas such as a container connection schema various schemas of dis tributors a supply schemas of heating circuits typical schemas of a boiler rooms schemas of furnace rooms in drawing etc Heating circuits ET onisine conection 12 Floor heating circuit Dte Heating circuit contro 3 way valve Pra Heating circuit control 4 way valve Pra Heating circuit 1 Bra Heating circuit 2 ata Heating circuit with 3 way valve Pte Heating circuit with room thermostat U ytkownika Container connection v Sort Help Search Cancel OK Current unit centimetres A schema that is inserted in a drawing is usually exploded into its compo nents objects blocks representing devices are not broken Thanks to that a user can edit a drawing add descriptions etc A user can add his own and most often used schemas to the program To do this a user should e Save a required schema using the WBLOCK command Block should be saved in the folder C CadProfi UserData Components Sanit Block_schem e Using the MSLIDE
91. hange the order of attributes saved in a given object Because of that the order of attributes will not be changed when the same object will be processed once again A click in a value of attribute in a column Data enables a user to edit a selected attribute directly The Clear button erases data for selected attrib utes 92 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Attributes and descriptions Global edition of attributes The Attributes and descriptions command allows a user to edit attributes of many objects simultaneously After a command has been started the following text will be displayed in the command line Select CAD Profi object or Multiple The Multiple letter M allows to edit many objects simultaneously After selecting objects a dialog box is displayed in which all attributes from se lected blocks are available If values of attributes are various the Varies text occurs If the text is not changed then the given attribute will not be changed for any object an attribute is omitted during saving data The re maining data are saved in all selected objects kkk Attributes Data Name Varies DN Varies Manufacturer Armature Inserting texts The size of a text on plots in mm as well as target scale of plots should be specified in dialog After pressing the button Insert text a user should selec
92. have been added previously to the library Add standard attributes adding attributes to blocks Attributes are used to describe objects as well as to create specifications in CP 113 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Extending contents of the program Adding blocks to library System In case of adding complex blocks e g schemas to the library the option Add standard attributes should be turned off e Add marker of the base point marker of the base point is visible as a red cross This marker is added only to slides miniatures of blocks This marker specifies a point of inserting blocks in drawings e Colour of slides choosing of colour for slides of created blocks Col our of slides is set only for elements of blocks which were drawn on layer 0 with the colour ByLayer After a user has pressed the OK button the program runs If blocks are added from a source folder then particular blocks from this folder are inserted into drawing These blocks are modified and saved in a library If source blocks already exist they will be overwritten If the Objects from drawing option is marked a user should select objects and specify a base point for created block after pressing OK A slide a miniature for a created block is being created simultaneously A view of a slide is compatible with a current view Therefore a user should set view and zoom
93. he system e g from supply air for exhaust air in air conditioning installation it is necessary to start the Match properties command select a source object and then select all object for which a layer is to be changed Note Round rectangular and flex objects that belong to the same system are placed on different layers Example For air conditioning layers are as described below round objects are placed on 2DL_PRO_xxx layer rectangular objects are placed on 2DL_PRE_xxx layer flex objects are placed on 2DL_PFX_xxx layer The beginning of a name of a layer 2DL denotes air conditioning installa tion middle part PRO PRE or PFX denotes a form of an object and the last part xxx means a system or installation supply return etc Exhaust air Supply air 2DL_PRE_o 2DL_PRE_i 2DL_PRO_o 2DL_PRO_i ANN N N NNNN N N N N NN NNN ANININ NANANA NANNE NEME MEMENENE PD ES Flex NN NN N N NNNN N NNNNNN ANI N N NNNN NN NNNMNNN 2DL_PFX_o 2DL_PFX_i Note A user can turn off an automatic structure of layers for symbols and objects in CP System For pipes ducts cable trays and fittings layers specify the system or the installation Therefore these elements are placed on various layers even if an automatic structure of layers is off 71 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes duct
94. ics e Lines hydraulics and pneumatics e Marks 14 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Settings and interface of CP System Menu and toolbars zi Multisymbols Symbols all A Symbols schemes O Symbols plan T Symbols maps lines pillars 2 Marks 7H Cross symbols amp Delete symbols g Mirror symbols objects oo Objects and lighting an Switchgears Circuits numbering E Cable trays electrics Cable edit h Cable trays a Cable trays sequence a Join cable trays ch Divide cable trays Y 2D edit and info Walls O Doors windows M Furniture and equipment Z Symbols and marks A Safety and evacuation symbols T Evacuation and tour routes HA Dimension A Dimension editing 124 Dimensions regen 4 Edit extension lines Electrics toolbar Ar TA a OHR ce by Electrics Multisymbols Symbols schema Symbols plan Symbols maps lines pillars Marks Cross symbols Objects and lighting Switchgears Circuits numbering Cable trays schema Cable trays plan Cable trays sequence Architecture toolbar znne gr aAa A Architecture Walls Doors windows Furniture and equipment Symbols and marks Safety and evacuation symbols Evacuation and tour routes Dimension Dimension editing Dimension regen Edit extension lines 15 JL Systems Group Slottsmollan 302 31 Halmstad Sverige
95. ill be downloaded from server is displayed under the list of available updates 3 Downloading files a user downloads all available updates Updated program has an option of transfer resuming If a connection with server is disconnected downloading updated files will be resume from discon nected place During downloading big updates the program can work in the background and a user can continue his work in CAD program 4 Installation after downloading files a user has to install them It is necessary to close CAD program during the installation When a cor rect installation has finished CAD Profi Configuration program can start This program configures CP System to a CAD program with all changes that were downloaded in updates By installing of updates it is possible to turn on the Make a copy of updated components options It guarantees that copies of all updated files will be saved Later these copies can be used to restore previous version of the program using the Restore previous version button Notes e After restoring previous version of the program it is recommended to start CAD Profi Configuration in order to configure Cp System to CAD program with parameters of previous version e CAD Profi on line Update program requires connection to the Internet using http protocol If it is corporate network administrators may sometimes introduce limitations on the Internet access Then updated program will not be able to conne
96. ined in pcp files A user can find more information about layers and plot styles in the Layers in CP System chapter at page 108 Defining and edition user s pipes or installations A user can specify additional types of pipes or installations They are saved in UserData folder see page 8 and111 After pressing the Add button a dialog will appear where a user should specify the name and the style of an added installation A style of an installation contains colour definition linetype definition as well as a definition of lineweight for schematic pipes one line pipes and for 2D pipes W Edit installation User installation Name New element 1 Text notation of pipe max 25 signs Category Trade Add to most recently used installations Schematic pipes Line color 7 Line type continuous Line weight New01 Main Heating Plumbing heating Pipes 2D a m Line type F By layer Line weight 0 15 mm v continuous 41 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas The colour has an influence on the lineweight in plots in CP System program That is why after changing of a colour the program will suggest an appropriate lineweight Unless styles of plots files ctb of CP System program see also information at page 108 are used during printing a user can selec
97. ing a user can number automatically suffixes In order to turn on this way of numbering a user should mark the Fix number option as well as Number suffix Then CP System will number automatically the last segment in a whole number An example of multilevel numbering W4 7 1 W4 7 2 W4 7 3 W4 7 1 2 1 W4 7 1 2 2 W4 7 1 2 3 7 1 2 1 7 1 2 2 7 1 2 3 97 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Numbering of objects Numbering Type of numbering Prefix V Use automatically free numbers V Prefix from system name C Allow number repeating Automatic position Draw leader Size of numbers Height 2 Current unit millimetres During numbering a user can assign automatically next free numbers After turning off the Use automatically free numbers option a user can number objects starting from any given number CP System monitors process of numbering thanks to that assigned numbers are unique in a given sequence of numbers If a user turn on the Allow number repeating option he can repeat numbers in a given sequence During numbering of objects a user can insert texts of numbers with a leader The point of inserting of numbers is specified by a user It is possible to turn on the Automatic position option in which texts of numbers will be inserted directly in numbered objects The size of te
98. ings e g supply pipe in plumbing installations should be red For objects which have colour independent of a norm a user should use colours that enable to assign lineweight on plots 109 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Layers in CP System Plot styles CadProfi Color and CadProfi Mono have 4 lineweights defined A table of colours for particular lineweight is displayed below Colour of print 0 15 mm 0 35 mm 0 5 mm 0 7 mm szer obiektu black 13 23 11 21 15 25 17 27 19 29 colour 16 26 14 24 10 20 12 22 18 28 Colours 18 28 19 29 do not have defined the width of print i e they have set the width of an object and are not used in CP System program That is why a user can use them in any way in CP System no conflict with a structure of program layers will occur Show 2D 3D layers Show all layers These commands enable a user to show or hide quickly 2D or 3D layers The Shows all layers command turn on visibility of all layers in a drawing Note The commands work correctly in drawings in which structure of layers of CP System program is used Freeze layer groups Thaw layer groups These commands allow a user to lock and unlock all layers of a given trade e g plumbing heating air conditioning or electrics installations quickly
99. ions During inserting some objects e g screw joining two points should be specified The first point is a base point of an inserted block while by means of the sec ond one the automatic length i e the distance from the base point to a nut is calculated For screw joining CP System controls minimum and maximum length of a joining for selected type of screws An example of a screw joining In order to insert a screw joining i e a screw and a nut a user should select an appropriate type of joining in a dialog and a required size of a screw Then he should specify a point of inserting P1 and the thickness of a joining P2 in a drawing Note A user should select the appropriate length of a screw in a dialog Selecting for instance 30mm length screw for 40mm joining is a mistake Too short Proper length of A screw with a too screw a screw short thread 85 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Mechanics Steel shapes Steel shapes The command works in the same way as the Parts command During inserting steel shapes in 2D view specifying the length of a drawn shape is necessary Similarly to other objects a user can specify his own dimensions It allows to create very untypical solutions A Steel Shapes Steel Shapes Atticle 8 Sio O L shapes equal angles 10x5 L shapes unequal angles ore U shapes economic Sis U shapes ha
100. ixed layer which name is specified in a dialog The colour the linetype and other prop erties of a fixed layer can be specified using appropriate commands of CAD program Note CP System identifies type of pipes by means of layers That is why schematic pipes or ducts or cable trays and fittings are always in serted on automatic layers Additional information about layers a user can find on page 108 17 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Settings and interface of CP System CAD Profi Options Style of isometry A user can create isometric drawings in CP System It is possible to create rectangular dimetry and dimetry at any angle When inserting symbols in axonometric drawings CP System match auto matically an obliquing angle It is done according to an angle that is specified in CAD Profi Options dialog Most often an angle 30 is used for isometry and an angle 45 is used for dimetry A user can specify other angle between 5 and 85 While a user is creating an isometry AutoCAD program or IntelliCAD makes a special snap and grid mode available A graphic cursor is matched to an upper a right or a left isometric plane in snap and grid mode For other kinds of an we axonometric drawing H CP System program allows switching ve automatically a obliqu a ae ing angle of a graphic i G cursor compatible with a current isometric Isometry 30
101. lected pipes can be organized using buttons Move up Move down Delete and Copy 2 Ba After clicking the OK button a designer should specify points between of which the program will draw pipes The way of drawing is similar to drawing lines in CAD program Pipes can be drawn in two views Type of installation or Type of pipe When a user wants to draw pipes in a view Type of installation he should uncheck an option Draw by type of pipe In such case selected pipes will be placed on appropriate layers according to data included in internal data bases On the other hand if a user wants to draw pipes in a view Type of pipe he must check an option Draw by type of pipe and in column Type of pipe of the list of selected pipes specify required type of a given pipe e g DN50 In such case pipes will be drawn with linetype determined by entered text Example drawing pipes moved away from a wall supply and Return should be added to the list of selected pipes Specify the distance from a Oki Space 20 wall and the space between O conter ERES pipes O right istance 0 Select drawing on the left edge When a user has clicked the OK button he should select points lying on the edge of a wall P1 P2 P3 P4 Pipes will be drawn automatically with a given distance from a wall 36 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HV
102. lement by mistake he can retrieve it In order to do this he should select the Restore removed option from a context menu directly after removing a pipe p Add to favourites Copying a pipe to the Favourites category In this way a designer can create a list of the most often used pipes x Ep 37 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Note Only pipes defined by a designer and placed in the User or Favourites category can be removed and edited Add element to a list Adding a highlighted pipe or set of pipes to a list of pipes f Save as set of pipes Sometimes it is necessary to draw specified pipes next to each other CP System allows to save such pipes as set Adding a set of pipes to a list of selected pipes causes removing all previ ously selected pipes The edge of drawing distance It is possible to draw pipes by axis by left or by right edge Left and right edge are determined by the direction of pipes drawing points P1 P2 While a designer is drawing by left or right edge he can specify the distance from drawn points Thanks to that it is possible to draw pipes e g along the walls Distance Left edge Right edge pi osme TTT pp n TIL Mle 38 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl
103. les of sequences of automatic numbering e Numbering of plumbing pipes and fittings a unique numbering for installations supply return gas etc e Numbering of air conditioning ducts fittings and objects a unique numbering for particular systems supply air exhaust air etc e Numbering of plumbing symbols objects and armature common num bering is used for all objects e In case of using additional libraries of symbols a unique numbering will be used for particular modules CAD Profi Electrics CAD Profi Architecture CAD Profi Mechanics After a user has started the Numbering command he should select an object or a symbol that has been drawn in CP System program If a selected object does not have any number yet then a dialog with options of number ing is displayed If a selected object has already got a number a user can switch the program to mode of removing numbers Assigning numbers In a dialog a user should specify the way of numbering as well as the size and appearance of inserted numbers The way of numbering A number can consist of three parts Number can only be a whole number integer from 0 to 32767 Prefix any text Prefix is most often used to mark an installation or a system e g V4 can denote fourth outlets system The Prefix from system name option is used to automatic assigning prefixes based on names of systems Suffix any text In case of using multilevel number
104. mbol inserting is always fitted to an angle of pipe P27 P1 P2 P1 pry vi gt 2 Z 2 Without rotate With rotate 28 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Note During inserting symbols in pipes a user can use extended structure of layers in which a symbol layer depends on a name of a pipe layer Additional information are available in the Layers in CP System chapter on page 108 Inserting symbols in any points In order to insert a symbol a designer should specify a P1 point If the Angle option is active a symbol will be inserted at angle specified in the dialog If the Rotate option is active a user should specify a second point P2 to specify an angle of an inserted symbol P1 P1 JL JL 0 angle 30 angle Without rotate With rotate Using symbols inserted with a fixed angle Some symbols are inserted with a fixed angle in order to keep correctness of a project Examples can be electricity meters sludgers separators etc These symbols should be inserted at angle 0 In CP System there are many symbols that have a fixed angle of inserting Inserting this kind of symbols in horizontal or vertical pipes causes automatic breaking of pipes In other cases pipes are not breaking P1 i A Vertical pipe Horizontal pipe Oblique pipe Notes e The Angle and Rotate options are ignored for symbols that have a
105. mechanical designs we recommend to set module CP System sug fixed linetype scale Factor k in command line set variable _Itscale gests turning off automatic matching of linetype scale Automatic settings of linetype scale Factor The automatic matching of can be set in dialog box Settings linetype scale to units can Do you want to set fixed scale Factor be turn on again in any moment in the dialog box ee j CAD Profi Options Don t show this message again e When dialogs are not displayed e g in the Save command Some CP System commands block displaying standard AutoCAD Intel liCAD dialogs CP System restores displaying of them after a user has finished such commands normally Sometimes a user breaks a CP System command e g by pressing ESC keystroke In such cases CP System may not restore displaying of stan dard dialogs If a user wants to restore displaying of them he should set variables FILEDIA and CMDDIA to 1 In order to do that a user should enter a name of the variable in command line and set its value to 1 Command filedia Enter new value for FILEDIA lt 0 gt 1 Command cmddia Enter new value for CMDDIA lt 0 gt 1 A user can restore displaying of standard dialogs by means of CAD Profi Op tions command e Cartesian coordinate system The most CP System commands can be used in UCS However some commands require the coordinate system to be set to WCS It is the de fault coordinate syst
106. n about working in CP System Important information about working in CP System Designing in CP System is compatible with general rules of designing in AutoCAD IntelliCAD programs The most important benefit of the program is that the program automates the most drawing activities and provides an extensive base of objects and solutions ready to use in created projects CP System commands work in an intuitive way However it is strongly rec ommended to read this user s manual because it allows a user to use full possibilities of the program To work comfortably in CP System it is necessary to get to know the most important assumptions of the program Compatibility with dwg dxf formats Designs that are drawn in CP System are saved in dwg or dxf format These drawings can be edited in CAD programs even without loading CP System application Standard drawing CP System inserts layers text styles dimension styles and linetypes definitions saved in a template file into every new drawing A file nor mal dwg normal_lIt dwg is a template file for AutoCAD AutoCAD LT whereas a file normal_ic dwg is a template file for IntelliCAD These files are stored in a folder Block General By changing template files a user can change or expand standard defini tions of styles that are being loaded Drawing scale A user should make all projects to a scale of 1 1 in model space and in selected unit of designing mm cm m A user specifies targ
107. nd sections Inserting of parametrical objects Inserting an object in any point In order to insert an object a user should specify a point P1 and then the second point P2 specifying an angle Container Instead of specifying the point P2 a user can enter a value of an angle in the command line side view Inserting of an object in 2D pipe In order to insert an object in a pipe a user should specify a P1 point that is placed close to the end of the 2D pipe CP System defines automatically the end of the P1 pipe that is a reference point Then a user should specify a point of inserting of an object He can also enter a distance from the refer ence point from the beginning of a pipe or specifying a P2 point a point of inserting is a perpendicular projection of the P2 point in the command line For many objects a point P3 can be specified It specifies a way of inserting of an object e g position of a handle of a valve 48 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Plans and sections Examples of parametrical objects inserted with its own dimensions Frame of dimensions Pump 1 Pump 2 Flanges D1 9185 DN65 200 DN80 D2 165 DN50 185 DN65 Other dimensions H1 180 160 H2 225 200 ut 100 100 Le
108. ng F 0 and muff ending E gt 0 E gt O t A two segment elbow A segmented elbow A segmented elbow with revisory door 129 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Round fittings An elbow Z or Z view directed up or down Z Z elbow is exported as 2D round elbow in specifications Presented view is also used for all types of round elbows segmented etc A reducer e Asymmetric reducer e An asymmetric reducer e An asymmetric reducer with a shift on Z axis Z 0 in specifications A fuller A fuller TYPE2 three segmented A segmented fuller 130 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Round fittings View for fullers Z Z Symbol on higher side oD3 l 3 A tee piece aD i Z O F Re A tee piece Z Z a ah nal D _ Q L E A tee piece with reducer gD f D2 p D5 A reducing tee piece 131 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Round fittings A round rectangular tee piece A3xB3 A round rectangular tee piece Z Z A taper tee piece A taper tee piece Z Z 003 o A
109. ngs In order to obtain proper colours and lineweight on plots of drawings created in CP System a user should use CadProfi Color ctb and CadProfi Mono ctb plot styles These files should be copied from a CAD Profi folder e g C CadProfi xx PlotStyle to a CAD folder e g C Program Files AutoCAD Plot Styles Files pcp are used in IntelliCAD program C CadProfi xx it is a default folder of CP System program Structure of layers Name of created layers consists of several segments segments are sepa rated by signs _ A prefix of layer name specifies the trade of designing and a type of created drawing 2D 3D isometry etc e The second segment specifies a type of an object e g symbol pipe duct etc e Another segments of name of layers specify a specific installation type of material type of pipe etc e g S supply R return These seg ments are created when the Extended layer name option is checked in the dialog CAD Profi Option page 18 There are also special layers for special purposes details axes hidings On special layers objects such as texts of tables etc are placed Colours of layers Colours of automatic structure of layers in CP System are adapted to black background of graphical screen of AutoCAD Only some colours in range from 10 to 249 are used for keeping ergonomics If a colour is specified by a norm it is recommended to use colours compati ble with a norm in draw
110. ngular round tee piece Z Z A cross 124 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Rectangular fittings A cross Z Z A cross simple ve EE A cross simple Z Z B4 A reducing cross A rectangular round cross 125 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Rectangular fittings A rectangular round cross Z Z A2 A tee piece branch AxB yY A3 A view for tee pieces branch Z Z A cap external paer L B A A cap internal 126 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Rectangular fittings A coupling e Filleting with zero radius e Filleting with nonzero radius on one or both sides R A2 h BI A lt 7 A coupling TYPE2 e Chamfer distance zero e Chamfer distance nonzero on one or both sides A2 IA A flange During inserting flanges a user can turn off considering them in specifica tions Il A round rectangular tee piece This element is available in a list of round fittings A round coupling This element is available in a list of round fittings A round coupler is used to join round pip
111. nit Factor 1 1 E Misc OTHER Update ww cadprofi com PRICE Name 2hpn_stratos_2z_030_1_8a_gl EQUIPMENT Path QUANTITY Rotation 90 WEIGHT E Attributes wean POWER OTHER Update www cadprofi com FLOW PRICE TEMPERATURE EQUIPMENT PN PNIO X WANTITY The Properties dialog in Bricscad The Properties dialog in AutoCAD Fittings have defined a unit mass Thanks to this a user can obtain informa tion about the length and the mass of elements that are inserted in a draw ing He can also obtain automatically full specifications of steel or other metals Most CP System shapes are steel elements prepared according to specified norms A user can specify any dimension It allows to insert untypical shapes aluminum shapes copper ones and other If untypical sections are inserted it is necessary to correct the type the kind of material and unit mass or total mass of inserted elements These parameters can be corrected easily with the use of the Attributes and descriptions command This command enables change data for many selected objects simultaneously see page 92 87 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Mechanics Steel shapes An example of marking the mass of shapes e The mass 1 76 m denotes a unit mass 1 76 kg per one meter of length of a given shape During creating specifications the program counts the mass of an element taking into consideration his length e The m
112. nts in CP System are drawn without an axis to distinguish them from objects with other cross section Most elements have various views in CP System program e g 2D view side view Thanks to this it is possible to draw both plans and cross sections with pipes or ducts and fittings that are placed horizontally or vertically in relation to a plane of a given drawing Vertical views of fittings or pipes ducts are marked as Z Z views in CP System All names of Z Z fittings and pipes are used only to distinguish views In specifications all Z Z elements are treated as 2D elements In specifications a surface of pipes ducts and fittings can be calculated Calculations concerning the surface are based on EN 14239 norm A user can also include dimensions or types of fittings or pipes ducts Only elements selected from databases of manufacturers have got the type In other case the type is not specified and main dimensions of elements are included in specifications These dimensions are compatible with dimensions on drawings in the list of 2D fittings We recommend to print and to attach it to a specification of elements The list is placed in file Manual pdf in sub folder File_gb Cable trays protective pipes cable ladders and other elements are available in Electrics module Some fittings presented in a list of 2D fittings are not used in electrics and therefore they are not available in this module Flex pipes or flex protective pipes
113. of columns that are set in a main window of data After setting a cursor of a mouse between columns the cursor will change for two way arrow that enables a user to change the width of selected columns Width_of_table Header of table Frame of table Legend Distance between columns Consider column Sum Blockname Name CK Valve y Distance between rows Dec Safety vive Oryginal All data in column Description i Tes Stop valve KSB DN100 PN16 107 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Layers in CP System The Specification mode is used to fill template tables of drawing specifi cations Tables of specifications are prepared on the base of the suitable norms That is why tables of specifications have precisely specified order the width of columns the size and the style of texts etc When inserting tables of specifications a user should pay attention to choose the same columns in Specification Wizard and a given type of tables Otherwise tables will not filled in a correct way The All data in a column Name op tion enables a user to consolidate various data to a column containing various descriptions Note Specified system of names of particular parameters is established in the program such as Name Type DN PN etc Using other names is required in some tables e g a parameter
114. oftware Full compatibility with dwg CAD Location Autodesk Mechanical Desktop 2008 C AMDT 2008 AutoCAD LT 2006 C ACLT2006GB AutoCAD LT 2009 C ACLT20096B BricsCAD Bricscad C BricsCad_en Bricscad V8 en_US C Bricsys_en8 2 Bricscad V8 pl_PL C Bricsys_pl8 2 Bricscad 9 en_US C Bricscad_V9en Bricscad V9 pl_PL C Bricscad_ 9en Select CAD Profi program Check updates OcP Manufacturers OcP Symbols cP System o xX Restore CAD Configure CAD Restoring of CAD program settings To restore previous settings of CAD program the Restore CAD button is used Once it has been done it is recommended to rerun CAD program Only if CAD program is turned off can a user do configuration and restoring its settings Otherwise changing of setting may not give any effects 10 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Installation Configuration of CP System to the CAD program Notes about IntelliCAD program During configuration of CP System to IntelliCAD it is recommended to use CAD Profi Configuration program This program searches automatically the most popular distributions of IntelliCAD If a user uses untypical distributions he should add line RegICADKey NameICAD in C CadProfi xx cpabout ini file which is placed in Setting section NamelCAD is a main name of a key of IntelliCAD program which is used in HKEY_CURRENT_USER Software branch in r
115. og page 18 Turn symbol allows a user to SR Angle Mirror and isometry insert reverse symbol e i di Fi Tuma symbol rected in the opposite direc Rotate Ra tion Symbol orientation Symbol orientation allows a O Angl e Mlisometn user to insert symbol that is rotated towards a selected iso metry axis Symbol orientation can be different in particular isometry axes It means that by the same settings a given symbol inserted in a right axis may have a horizontal orientation however inserted in a left axis may have a vertical orientation So if a user wants to design efficiently he should gain experi ence designing in CP System J Poe ao Isometric views for symbols are generated dynamically Some symbols were not expected to be used in axonometric drawings For such symbols isometric views can be generated incorrectly 27 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas A user can add new symbols to CP System by himself see page 111 These symbols can also be used in axonometric drawings It is sufficient to add usual symbols to the program and isometric views will be created auto matically by the program During defining his own blocks a designer should avoid using complex objects like solids multilines hatching etc During defining his own blocks a designer should avoid using complex objects like solids multilin
116. ols with an ability to change their order size angle or distance e Most recently selected symbols option a allows a user to select sym bols that have been used recently during using Multisymbols command e Find option Ga displays additional dialog where a user can find symbols according to given words D4 Clean opening on a line Clean opening on a line Clean opening on a line Clean opening on a line gt Clean opening riser pd Cleaner gt Cleaner pd Climaconwector pd Clock Z Clock Da Closed cooling tower Searching parameters A Clothes dryer Any part of name D4 Clung temperature sensor Da Clung temperature sensor p Clung thermostat pd Cock Da Column with specified number of trays v lt gt Clung thermostat Match case Multisymbols option System during inserting a few symbols CP System is drawing pipes be tween particular symbols If a user inserts single symbol in a drawing a pipe will not be drawn Using extended structure of a layer a selected pipe speci fies a layer where a symbol will be inserted For instance the Supply pipe symbol will be inserted in 2DH_SYM_s layer the Return pipe symbol will be inserted in 2DH_SYM_r layer If System is turned off or if extended layer name is not used symbols will be inserted in 2DH_SYM layer 22 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Elec
117. ometry CP System activates isometric mode of a graphic cursor Thanks to this specifying position and an angle of inserting text along demanded axis is easier axes are placed at an angle 30 150 and 270 in isometry Only if a current angle of isometry is set on 30 will isometric cursor be set automatically If a user wants to insert text in dimetry he can enter an angle of inserting in the command line It is the most convenient way This angle has to be com patible with an angle specified in a dialog CAD Profi Options page 18 If specified angle is other than 30 then CP System assumes that the dimetry will be designed Therefore a graphic cursor is switched in normal mode rectangular snap and grid 94 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Attributes and descriptions Defining and using additional parameters Most objects have standard attributes in which a user can specify basic parameters If additional parameters are necessary for description of objects it is possible to define them In order to do this a user should select a button Sa Addtional parameters and then specify names of additional parameters These parameters will be available for every object of CP System Data included in additional parameters can be used in specifications or de scriptions Notes W Additional parameters bd Additional parameters are not Spe
118. on of elements If a button occurs on the right side of the given field when the field is active then a user can choose a m E o E E O 200 m m m o m i A x 315 typical dimension from a database 355 Dimensions a wm Dimension A 50 Typical dimensions Dimension 42 50 Lengths of tee pieces reducers and other fittings Lengths of fittings are specified automatically After turning off the Length automatically option a user can enter any lengths Lengths automatically Iv Length L 35 2 Length L3 30 1 Angles of elbows tee pieces and other fittings e For elbows angles must be different from 0 The maximum angle for elbows is 180 Only 90 angle is available for some fittings e g reducing elbows e For tee pieces and crosses the angle must be greater or equal 5 and less or equal 175 Angle Alfa 930 Radius R 75 1 5 Use multiplier 56 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Inserting fittings Pipes Ducts Cable trays When inserting pipes ducts cable trays a user should specify an insertion point the beginning of an object P1 and then a second point the end of an object P2 The object will be drawn between these two points P2 P1 Fittings Most fittings can be inserted with automatic joining other fittings or in any point e Ifa fittin
119. ons as well as complete lists of elements E Data printing from current drawing You can sort data and specify width of columns Title Report data t Up Dom X Remove Number Name L shapes equal angles L shapes equal angles L shapes equal angles L shapes equal angles L shapes equal angles Welded square structural tu Producer EN 10056 1 2000 EN 10056 1 2000 EN 10056 1 2000 EN 10056 1 2000 EN 10056 1 2000 EN 10056 1 2000 EN 10219 2 2000 Article 20x 20 3 20 20 3 20 20 3 40x 40 4 40x 4044 40 40 4 25x25 Weight 0 10 0 10 0 10 0 33 0 33 0 33 2 46 Length 113 113 113 138 138 138 1500 Help User data Cancel Draw Csv export Print More information about creating specifications is in chapter Specifications on page 101 88 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Mechanics Symbols and marks Symbols and marks Typical marks of surface roughness are in CP System After a user has selected a symbol with numerical value a window is dis played in which typical values are contained amp Roughness surface S E General symbols roughness g O With a numerical value Ra O With a numerical value Rz E Obtained by take layers of material H E Obtained without take layers of material E Obtained before the process lt W Roughness Ra Article Value Class The Marks
120. opying a user can create a subcategory Favourites in which he can place the most often used elements Edit The button enables a user to change selected elements X Remove Removing selected elements from databases of a user Note A user can remove and edit only elements that have been added by himself User s data are saved in the UserData folder This folder is placed in main folder of the program e g C CadProfi xx Particular data are saved in uuc files A structure of these files is similar to a structure of csv files Because of that advanced users can edit them in any text editor e g notepad while the other should use only appropriate com mands of CP System to edit uuc files In order to keep user s changes a user should archive a whole UserData folder Thanks to this he will be able to restore all data when CP System will be moved to the other computer or will be reinstalled During updating user s data are attached automatically to every new version of CP System program 111 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Extending contents of the program Adding blocks to library Adding blocks to library Every CP System library consists of CAD blocks as well as a database in which names and other parameters are defined Blocks are saved in dwg files that must have an appropriate structure During adding new blocks there are also creat
121. ored When inserting symbols in pipes a user can use Rotate option This option is used to dynamic specifying a rotating of symbol regarding a pipe It is very comfortable during inserting symbols of pumps valves etc 23 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas rar ae E gt lt PL 0 angle Rotate ou 2 Inserting in a pipe with rotation P q Pe Inserting in a pipe 30 angle without rotation SS Inserting symbols A user can use following options to insert Angle Fotate Saree symbols 30 b 20 Q e Insert symbols it is a default option which can be used to insert symbols in ot Insert symbols X pipes or in any points Inserting a symbol Insert symbols in a pipe causes automatic breaking of Inextension Into specified point pipe in connected points Into many pipes e Into specified point this option allows to insert a sym r5 bol in any point When a user specifies a point lying on a P pipe the pipe will not be broken This option is used for instance to insert sensors etc e In extension this option makes possible of precise PL specifying a point of an inserting symbol towards other objects that are in the drawing Example of using in extension option inserting symbol in a pipe in the point that was indicated on the base of other symbol 1 When a user has selected
122. ouped in categories It makes easier quick choosing symbols used to designing specified kind of installation Plumbing heating Multisymbols Symbols categories and libraries Symbols to insert gt Armature x w t R H e Stop valve Three way valve Pump Non return valve Ball valve Stop valve Eimer Safety valve Control val v System Gate valve Routing c Pressure r Sludger EN Distance between symbols Distance 200 Stop valve Swing che Ball valve Angle Rotate Symbols scale Flanged b 200 Insert symbols Current unit millimetres 21 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas First a user has to choose a category of symbols and later select by clicking miniatures of demanded symbols Selected symbols will be added to a list of symbols This list can be organized in an easy way for example by dragging or by using of buttons X amp 4 Move down Delete Copy Move up A user can also choose symbols by using Select symbols Most recently selected symbols or Find commands e Select symbols command allows a user to select symbols from a current drawing During selecting symbols a dialog is hidden Selecting symbols directly on the drawing makes designing faster It also allows a user to do intelligent copying of symb
123. pes plan 2D Duets round A Installation and drawing mm Duct Installation E Fresh air recycled D Elbow E Reducer Elbow x eA Fuller Producer and type z ab as wo segment elbow ey Tee piece Producer Segmented elbow By Tee piece with reducer Type Segmented elbow with revisory door BY Reducing tee piece DSS 54 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Manufacturer and type Manufacturer and type selection of elements based on databases of manufacturers After a user has selected a given manufacturer an appropri ate dialog containing available dimensions of fittings will be displayed CP System draws fittings in two modes e Drawing based on norms or databases of manufacturers If a user wants to activate this mode he should select a required manufacturer or a norm After that it is impossible to enter user s dimensions because they are disabled e Drawing based on user s dimensions In order to ag Producer and type activate this mode in the Producer br Manufacturer field a user Type should select When a manufacturer norm has been selected a database with available elements will be displayed Types Article S A Symmetric R 100 CO 500x500 R 100 15 E a 50 C 500x500 R 100 30 amp Symmetric R 150 500500 R 100 45 J E As
124. ppropriate procedures Thanks to that a user can draw any fittings according to specified dimensions For fittings there are available databases containing definitions of standardized elements as well as elements of selected manufacturers Fittings are available in the following commands e Pipes this command contains typical pipes and fittings used during designing of plumbing heating installations e Ducts this command contains ducts and fittings used during designing air conditioning installations e Cable trays this command contains elements of trays used to design ing electrics e Pipes Ducts Cable trays sequence this command enables a user to draw many sections of pipes ducts cable trays and insert elbows automatically e Join pipes ducts cable trays this command allows to join easily pipes ducts cable trays with automatic inserting suitable fittings e g el bows bends reducers fullers tee pieces crosses etc All these commands display dialog with a list where a user can specify pa rameters for particular fittings A set of available parameters depends on the type of a selected fitting The meaning of parameters is similar for many fittings Therefore it is strongly recommended to read the rest part of this chapter Inserting 2D pipes ducts cable trays and fittings Pipes Ducts Cable trays command allows to insert a single fitting into a drawing Once the command has been run a user can select a
125. pressed The Mirror symbols command can be used only for symbols and objects created by CP System When a user selects other elements markers of mirroring are not displayed Example Using the Multisymbols command it is possible to insert many symbols at once in a drawing It is possible that some symbols are inserted improperly The easiest way to change their position is to use the Mirror symbols com mand Mirroring isometric symbols 35 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Pipes Schematic pipes There are different kinds of pipes in the program Each one has specified colour linetype and lineweight on plots These parameters are compatible with the norms Drawn pipes are placed automatically on particular layers It is possible to draw a single pipe or many pipes at once In the right part of dialog there is a list of pipes that are being drawn When a user wants to add a pipe to this list he should select a required element from a list of all pipes and press the Add an element to a list button He can also add pipes by double clicking or by selecting from context menu a right mouse button Choice of more than one pipe causes that pipes are being drawn with a given distance and with a specified order That is why the list of se
126. radius R 450 1 5D 119 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Rectangular fittings Rectangular fittings A rectangular duct L e Air conditioning duct Cable duct U cable tray AxB Closed profile cable tray Examples An air duct cable tray or closed cable tray B ERZ AA U profile cable tray in Electrics Z Z or Z view T vertical pipe duct Duct Z Z is exported as 2D pipe duct t or rectangular cable tray in specifica B L L tions Z A rectangular duct fit The length of fitting element is ex ported with 10 extra length in speci BI fications C L A A truncated rectangular duct J A truncated duct on one or both ends is only used in drawings during at taching to other ducts or objects at specified angle In specifications the L truncated duct is exported as 2D duct which a total length including cuts BI A 120 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Rectangular fittings A rectangular bend For truncated bends S dimension is greater than 0 S dimension is not exported for 2D bends 7i AD F A rectangular bend TYPE2 A rectangular bend TYPE3 A rectangular bend TYPE4 A2 Ds J IF JE ii A rec
127. rks page 32 Special symbols used to describe drawings Auto matic marks and symbols are described For them a user can select pa rameters from appropriate databases Below there is presented an example of automatic marking the size of schematic cable tray W Electrical Symbols all Automatic sign cable ray sian wy Cable ladders sign wo Floor tray sign E Switchgear controlgear and protective Architectural and topographical installatic g io E Lighting S E Measuring instruments Production and conversion of electrical Industrial automation and measurement Equipment for fire protection and fire figh a Alarm Installations Installations Cable ladd Telecommunications Grounding a Passive elements Active elements Floor tray selecting of a symbol automatic mark of cable trays Cable tray DEE e Removing symbols page 34 A user can remove one or many sym bols e Mirror symbols page 35 A convenient way to mirror symbols inserted in lines This command can be also used to other objects of CP System program 75 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Cable trays Cable trays The Cable trays schematic and Cable trays commands are used to draw cable trays see page 36 Cable trays cable ladders floor trays plas tic trays prot
128. s cable trays and fittings Dividing 2D pipes ducts cable trays When designing installations a user can draw pipes ducts cable trays with out concentrating on lengths of particular segments because it is possible to divide a long sections of pipes ducts cable trays into shorter elements The Divide pipes ducts command allows a user to do that quickly and easy A user can divide one or many pipes ducts cable trays depending on a used option Once a user has run the command he can select a pipe duct cable tray or one of available options in the command line Select pipe or Layer All Select byPipe If a user selects a pipe duct cable tray then CP System will activate a mode of dividing of a single pipe The following message will occur in the com mand line Select point enter distance or segmentLength Dynamically It is possible to select directly the point of divid P2 ing P2 or enter the distance of a dividing measured from the beginning of the selected object P1 The Dynamically option enables a designer to divide an object into variable length sections P1 Successive points should be specified to make dividing The segmentLength option is used to divide a whole selected object into fixed length sections A new length must be entered to make dividing CP System divides the object starting from the end lying closer to the selected point P1 Example of using the segmentLength option Select point or
129. s a user should start the 2D edit and info command select an edited fitting and change required dimensions and parameters in a dialog All elements of the dialog that is used to edit are the same as in the com mand used to insert fittings An important difference between this two com mands is that options used to automatic setting of dimensions e g the length are default turned on in a command to insert fittings These options are default turned off in an edition command it allows a user to specify all dimensions easily When editing a user can specify single dimensions of fittings or select typical fittings from databases of manufacturers or norms He can also change a type of a fitting e g an elbow can be changed for a segmented elbow a two segment one or an elbow with revisory door een ee An example of changing type of a fitting During editing of fittings the Copy option is available It behaves the same way as in the command used to insert fittings 69 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Example of edition of a tee piece branch e Pipes were joined using a tee piece branch The distance between branches is 200 mm e During designing it was necessary to move one of the pipes 100 mm up it caused the distance of the branches to be 300 mm now e In order to correct a drawing a
130. s been started a dialog is displayed in which a user should select a type of specification There are many prepared templates that are used to obtain various specifications A user can make separated or summary specifications for symbols objects as well as pipes ducts cable trays and fittings of appropriate installations Examples of templates e CAD Profi selected objects symbols and pipes creating summary specification with all types of elements inserted by CP System When creating specification a user can select objects from a current drawing e CAD Profi all symbols automatic creating specification with all symbols inserted by CP System When creating specification a user has not to select objects in a drawing all objects other than symbols will be filtered out e CAD Profi all symbols summary automatic creating specification with summing the amount of the same symbols e Selected CAD objects a very versatile template that enables a user to create specification with any objects CAD objects like lines arcs cir cles etc are taken into account as well e Plumbing heating pipes 2D fittings 2D a template to create specifi cations with elements of plumbing heating installations For every template various data are available They can be presented in tables All available data are placed in a left panel of a dialog Columns to print are placed in a right panel of
131. s in a drawing Drawing with the distance is used e g for partition walls P1 _ Axis of a wall direction of drawing gt a P 2 Pl A left edge of a wall gt P2 Pl A right edge of a wall gt P2 79 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Architecture Walls An example of drawing a partition wall In order to draw a partition wall a user should e Select the left edge of drawing in the dialog e Specify the distance which suits the width of the room e g 360 cm e During drawing select points P1 and P2 that are lying on the side wall of the building Pe The drawn The distance wall from the left edge P1 Defining and editing user s walls After a user has installed the program predefined materials and structural walls are available These elements can neither be changed nor removed by a user A user can define his own elements of walls on the basis of those materials Defined elements are stored in UserData folder see page 8 and 111 After pressing the Add button a dialog will appear where a user should specify a name and a style of an added material or a wall He should specify colour linetype lineweight and default thickness of the wall in the style The colour has an influence on the lineweight in plots in CP System pro gram That is why after changing of a colour the program will suggest an appropriate lineweight Unless s
132. se checking of updating on line _Updaterow _ option CP System will be reminding Levey 7 deve Bj Ueda roa about possibility of on line update every 7 15 or 30 days If a computer is connected with the Internet at that particular moment a user can run Updating program This program allows a user to check available updates and download them as well as installing selected updates The Update now button allows a user to run Updating program in any moment Program update runs in a few steps 1 Checking of updates the program is connecting with CAD Profi Server checks and displays all updates that can be downloaded for the given computer CAD Profi Updating on line Check updates Select 3 Download Install www cacl profi com Welcome to CAD Profi Update In order to check existing updates click Check updates If you want to restore previous version click Restore previous version Check all available updates including previously installed components i Restore previous version i Help x Cancel Check updates 19 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Settings and interface of CP System CAD Profi Options 2 Selecting updates A user can select updates that he wants to download in particular moment If a selected update is not selected a user will be able to download it later Total size of files that w
133. selecting symbols he should press ENTER or right mouse button Once symbols have been selected the Multisymbols dialog will be displayed again A user can specify all options of inserted symbols in this dialog Insert ing symbols takes place the same way as for symbols selected from program libraries e g inserting in a point or in a pipe P4 P5 FA P2 Copying of three symbols with inserting them in new pipe Note If a selected object is not compatible with the Multisymbols command it will not be added to a list of copied symbols Copying symbols from different modules for example symbols from plumbing heating and electrics is not allowed 25 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Symbols The command inserts single symbols When a user start the command a dialog with libraries of symbols will be displayed To make searching symbols easier symbols that are available in Multisymbols command are also available in Symbols command All symbols are grouped in categories in the dialog When a designer has selected a required category miniatures of all symbols from a given category will be displayed Moving a cursor over a miniature of a symbol a user will see its full name After checking Sort checkbox a list of categories and symbols will be sorted W Plumbing heating Symbols Armature ot p4 Gate valve
134. settings of a cursor J he should again select the curso rObliquity option An exemplary text from the com mand line during specifying another points of a pipe Specify the first point of a pipe or cursorObliquity Specify the next point or Undo cursorObliquity Specify the next point or Close Undo cursorObliquity Drawing dimetry in IntelliCAD Note about using the command line In order to select options a user should enter a letter or several letters which are capitalized in name of options In order to choose the Undo op tion in the example a user should enter a letter U and press Enter He can press a right key of a mouse or a spacebar instead of the Enter key 40 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Layers of pipes Every kind of pipe is drawn on a different layer In the main menu there are additional commands that make managing layers easier A user can use these commands to quick hide or show all layers that belong to the various installations Plot styles that are included in C CadProfi xx PlotStyle folder are matched to structure of program layers A user can choose either files to monochromatic plots CadProfi Mono ctb or to colour plots CadProfi Color ctb ctb files should be copied to appropriate folders of Auto CAD or AutoCAD LT program Plot styles of IntelliCAD program have been def
135. systems dk HVAC Electrics Edition of schemas Linetype scale Particular pipes are drawn with various types of lines for instance Return is drawn with dashed ea Kr g line DASHED Global scale factor is set using the CAD command _LTSCALE Default the LTSCALE 200 factor is set default to 1 00 in new drawings If E the value of this factor is too low or too high the pattern of this line can be not seen and the whole line seems to be continuous line A designer can set units to millimeters centime ____ dos ese ters or meters in CP System program And he bt Dq has to match the global scale factor to the edited schema For instance during drawing schemas _LTSCALE 50 in mm and with size of symbols 200 a user should set a global scale factor to a value from 50 to 200 Pipes in isometric drawings In order to design comfortably usual drawings 2D or various types of axonometric drawings a user can select optimal CAD settings in the Drawing settings section Only if one pipe is selected will mode of isometric drawing be available e Isometry a special mode of snap and grid is available in AutoCAD or IntelliCAD program A graphic cursor in this mode is adapted to design the isometry in which axes are set at an angle 30 150 and 270 In order to turn on this mode a user should select the Isometry option with an activa tion of a left upper or right plane A designer should turn on the ORTO mode during
136. t a point specifying the beginning of the first line of a text P1 as well as a point specifying an angle P2 Instead of a second point a user can enter the value of an angle e g 0 or 90 In order to insert texts more quickly the Rotate text option can be turned off In this case text will be inserted hori zontally The style of inserted text depends on current style in CAD program Inserted text can be edited subsequently with the use of appropriate com mands of CAD program It is also possible to insert texts in frames In order to do this a user should select the Draw frame option A leader can also be added to a frame Stop valve DN6S MST0140 Note e The Descriptions button is used to display descriptions and catalogue cards for selected object if a description is available in database Most often catalogue cards are attached to objects from manufacturers library 93 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Attributes and descriptions Descriptions in axonometric drawings The Attributes and descriptions command enables a user to insert texts in axonometric drawings In order to insert text in isometry or dimetry a user should select the option Text style Isometric or Isometric turned round Text style normal or isometric O Normal Isometric O Isometric tumed round When inserting text in is
137. t other lineweight Text mark is used during creating a name of a pipe It should be unique for all pipes Add to most recently used installations including an added element in a short list of installation in the 2D Pipes command Specifying and changing type of pipe Schematic pipes can be drawn in two views Type of installa tion or Type of pipe To change a view of pipes a user can use a Pipe Ducts Conductors edit command There are a few edit modes for specifying type of pipes A user can change an existing type of pipe for another type either by selecting it from a list or by entering a new name of the type It is also possible to copy the type from a pipe in a drawing by clicking Copy from pipe button A user can also change view of pipes either for Type of installation or for Type of pipe To do this an appropriate button should be checked W New type of pipe Edit mode O Edit type of pipe Change for a view Type of pipe Change for a view Type of installation O Delete type of pipe Type of pipe Apply to Plumbing heating V Aircondition Electrics O Apply to selected pipes Opel Cancel C To clear type of pipe a button Delete type of pipe must be on Clearing type of pipe means that it is impossible to change a view for such pipes Only pipes belonging to installations existing in a drawing can be chan
138. t rolled ne U shapes yield strength over 430 MPa T shapes hot rolled 1548 Z shapes yield strength over 490 MPa 15x8 Z shapes yield strength up to 490 MPa 15x10 H shapes Hot olled parallel flange steel IPE Dir O16 H shapes Hot rolled wide flange steel beams Di amp 20 shapes Hot rolled as Welded square structural tubing Cold formed wel G30 Welded round structural tubing Cold formed welc 35 Welded square structural tubing Cold formed wel 40 Welded rectangular structural tubing Cold formec 45 Welded round structural tubing For precision ape 350 Welded square structural tubing For precision ap Eso Welded rectangular structural tubing For precisio gt 79 oo 0o0o0op00000000000 a Mn Ctnal Darn lt S gt Geo o Show noms Layers Object style v Axes Details hatch M Insert as block v Hidings Texts M With attributes View On OView1 OView 2 Info on website How to add new elements OView 3 OView 4 Enter all dimensions Flat steel bars Hot rolled Current unit millimetres Help Search Cancel OK An example of drawing steel shapes After a user has selected a shape he should specify the beginning point P1 as well as the length and an angle of a drawn element P2 eee il i o eS 500 0 400 mm O gt 500 mm 0 88 kg 0 70 kg 400
139. talling program has been run a user should follow instructions appearing on the screen Choosing installed components All modules of CP System program are placed on a CD ROM disc During installation of the program a user can install all available components They will work 30 day after first running of the program with no limitations After that they will be disabled unless activation codes will be entered A user receives activation codes for the modules that were bought There are a lot of producers blocks PDF files as well as other components in CP System A user can install the program remaining selected libraries on CD However CP System will display an alert box with a request to insert appropriate CD every time a user wants to use these libraries Installation of additional components CAD Profi programs are developed all the time Once a user has received the newest version he can add additional components To add new or updated components a user has to run the installation pro gram This program will find a previous version and it will install new compo nents in the same folder on the hard disk JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Installation Configuration of CP System to the CAD program Configuration of CP System to the CAD program Configuration of settings of CAD program When a user has finished an installation of CP System he should run C
140. tangular bend Z or Z view directed up or down Z Z bend is exported as 2D rectan gular bend in specifications Presented view is also used for Z Z TYPE2 TYPE3 and TYPE4 bends Ar Sap Aoa A A2 pom I3 P A Io Y LZ IZ A 121 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Rectangular fittings A2 itt An elbow AxB b A A2 An elbow Z Z Ay F Zl tN 1 E E A WHE Fez A rectangular reducer e Asymmetric reducer e An asymmetric reducer A A2 e An asymmetric reducer with displacement by Z axis Z gt 0 A2 B2 in specifications L r XZ A l D I A rectangular round reducer Pa A fuller A 122 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Rectangular fittings A fuller bend A view for fullers Z Z Symbol on higher side A tee piece gt A tee piece Z Z A tee piece simple 123 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk List of 2D fittings Rectangular fittings Z ACY 3 8 a A tee piece simple Z Z A Ft L3 A reducing tee piece A _7 A2 B2 A4 B3 a tes A A rectangular round tee piece A recta
141. tems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Settings and interface of CP System Menu and toolbars Settings and interface of CP System Menu and toolbars When a user has started CAD program additional toolbars and additional main menu of CP System will appear Main toolbar Th Previous library Th B A ca p A TS 20 30 AL Attributes and descriptions e Products library Numbering e Previous library Plumbing heating e 2D 3D Plumbing heating commands P e Attributes and descriptions Aircondition commands e Numberi ng Q Electrics e Tables Frames Electrics commands e Specifications D Mechanics e Add block to library Mechanics commands 5 e Users objects library Architecture e User s symbols library Architecture commands e CAD Profi Options S CAD Profi Options e About e Help Show 2D layers Show 3D layers PEE Geis dye CP System Edit toolbar CP System edit Freeze layer groups x Al Thaw layer groups A Ay 8 a ey Add block to library e Delete symbols ir User object library e Mirror symbols ee ty artes SY e Pipes ducts conductors edit m Title tables e Join pipes ducts cable trays 3 Specification e Divide pipes ducts cable trays Ay About e 2D edit and info Help Commands of CP System Edit toolbar are used to edit objects created in all modules 13 JL Systems Group Slottsmollan
142. ternet button If the activa 5 ID number 3504729112 713 tion by the Internet is not STEETS roon possible Another activation Status of modules entering activation codes met hod butto ns ho u l d be Producers found folders 18 HVAC pressed In this case a form Electo will be displayed which needs Mechanics to be sent by an e mail A Acitecture user can also print it and Z Do you want to send data needed for user registration send it either by fax or by aon nee E mail Sumame name Jan kowalski After that he ll receive activa ina Desing L i ountry Poland tion codes which he should Address Druga street 297 124 enter in appropriate fields of Code town 01 099 Mikowice the dialog Telephone Fax 047 1234567 E mail lian kowalski designing ord Dealer Close Another activation method Activation via the Internet gt Notes e When the checkbox Do you want to send data needed for user registra tion is checked only information in dialog will be sent We encourage you to register because only registered users are informed about new CAD Profi versions If a user is registered he can also get access to updating or to take additional components by the Internet e Authorization codes are appropriate only for one computer If a user wants to transfer the license to other computer he needs to activate program once again 12 JL Sys
143. th an ordinal number Header of a company this option enables a user to print a header of a company on the first page of specification Data for a header as well as company logo are specified in another dialog containing initial preview of plot Specification Select type of specification Selected objec mbols and pipes CAD Profi Available columns Printed columns Area Number Blockname Add all gt gt System Characteristics Name Diameter Form Dimensions Add gt Producer Duct pes Article Flow DN Group lt Delete lt lt Delete all Specification print setup Summing data Landscape print Open data Sort C Header of a company Save data Skip special symbols C Ordinal number on print 102 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Specifications Summary specifications Except for creating specifications from a current drawing a user can also create specifications for designs that consists of several drawings In order to create a specification from several drawings a user should create a temporary file in which data from every drawing will be saved Then this file can be printed as a summary specification The Save data button is used to create a file with temporary data After pressing this button a user should specify a file in which data will be saved If an e
144. that a default a global scale factor for lines is matched to architectural projects In mechanical designs it is essential to change the linetype scale factor A default value of factor is 99 9 during designing in mm 9 99 during designing in cm and 0 0999 during designing in m in CP System If a global scale factor is 1 0 in saved drawing CP System will change it for one of default values when a drawing is open A user should set any linetype scale other than 1 0 or default values by himself to make CP System not to change a global scale factor Changing of linetype scale is done by the command _LTSCALE Once a command has been started a user should enter a required value e g 5 Here is an example of changing of linetype scale Command _ltscale Enter new linetype scale factor lt 99 9000 gt 5 Parts In CP System there is an extensive set of standard elements for which vari ous views are available In case of necessity of using element with non stan dard dimensions a user should mark the Enter all dimensions option and then specify required dimensions in a dialog W Mechanical Standards Bolts A Aricle 5 Ius O Hexagon head bolts Product grade B MIERIZ O Hexagon head bolts Product grade C M16a16 Hexagon head bots Product grade B Reduced shank A 449 5 O Hexagon socket head cap screw Ones O Square head boks C Square head bolts with collar SLE C Knurled thumb screw with low head M40 C Knurled thumb scr
145. trics Edition of schemas gt lt lt t gt lt 4 D 1 4 Various pipes drawn between symbols Distance between symbols inserting a few symbols a user should specify distance between them He can do this in two ways First one specifying the length of sections that are drawn between symbols Second one specifying the distance between base points of particular symbols If a user set distance 0 symbols will be drawn one after the other This op tion is used for instance during inserting a few symbols of distributors 300 Distance between symbols Distance 0 between symbols 300 gt A Distance between base points Symbols scale specifying a size of inserted symbols Designing schemas dimensions of symbols does not have to be the same as real dimensions If a user wants to have readable drawings he should keep an appropriate ratio between other symbols and objects In CP System there are schemas where 200 scale symbols were used It is recom mended to use mm unit for this scale a If a user uses cm units then the rec ommended scale will be 20 and for Scale 200 Scale 100 m units the recommended scale will be 0 2 Angle Rotate a user can specify a fixed angle of inserting symbols or turning on an option rotate and insert symbols at any angle When symbols are inserting in pipes an angle of inserting depends on an angle of a pipe an angle specified in dialog is ign
146. tyles of plots files ctb of CP System pro gram see also information at page 108 are used during printing a user can select other lineweight Text mark is used to name a layer on which a wall will be placed 80 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Architecture Walls Edit materials of walls Materials of walls of a user Name Max brick Text notation max 25 signs Max Category Basic materials Default thickness of a wall 115 mm Parameters of a layer of a wall Line type continous SSS eel Line weight 0 50 mm Line color 9 Elements defined by a user can be copied removed and edited with the use of appropriate buttons or context menu This menu occurs when a right mouse button is pressed Copy Copying selected element to the User category Edit Changing colour linetype and other parameters of a wall x Delete Removing of selected definitions of user s walls When a user has removed an element by mistake he can retrieve it In order to do this he should select the Restore removed option from a context menu directly after removing an element p Add to favourites Copying an element to the Favourites category Thanks to that a user can create a list of the most often used materials or types of walls Note Only walls defined by a designer and placed in the User or Favourites category can be removed and edited
147. uld select a described object and then specify the point of mark For some symbols it is possible to turn on the option of inserting symbols with leaders A user should use appropriate symbols to describe various objects For example the Mark of rectangular duct symbol is used to describe a size of diameter of an air duct If a designer uses this symbol to other objects Cp System will not be able to read expected data In this case a symbol will be described in wrong way In case of marking many objects e g description of pa Insert symbol J air ducts the best solution is to choose the Insert Insert symbol repeatedly option In order to do this a user should Insert repeatedly open options available under the Insert symbol button Examples of automatic marks e Diameter of air ducts e Types of pipes symbols of marks inserted in pipes e Size of armature symbols of marks with automatic leader e Nominal size of pipes 315 anaes H DN25 250 ae X Y Ojo OjO r DN100 N a z N z p P 33 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Edition of schemas Removing symbols and armature The Delete symbols command is used to automatic removing symbols and armature If removed symbols were inserted in pipes CP System merges these pipes During removing numbered symbols numbers are also removed A us
148. urce blocks If source blocks are scaled set parameters for destination blocks to be scaled to meter unit O mm O cm im Scale 1 1 Options Type Automatic Prefix of blocks names v Add to database Color of slides 2 v Add standard attributes v Add marker of the base point Help Library editing Cancel JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Extending contents of the program Adding blocks to library In a dialog there should be specified parameters of added blocks Unit and scale unit of source blocks should be specified If source blocks are drawn in scale then a user should set parameters for blocks to be rescaled to a unit meters Example real device has got dimensions 20 cm x 30 cm A block presenting this device has got dimensions 200 x 300 It means that the block has been drawn in mm Because of it a user should mark unit mm and scale 1 1 in a dialog If new symbols are added to the program a user should enter such a value of scale as if target symbols have dimensions about 1x1 A lot of original symbols included in CP System have such dimensions Example Symbol on a drawing is 200 long A target symbol is to be 1 long A user should rescale source block 200 times So an entered scale must be 1 200 0 005 Category specifying the name of a category of added blocks Type 2D 3D Front
149. uring exporting data a user can specify parameters of export in details e g only export of data or export data with keeping formatting 105 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Specifications A program to display LL files A preview of plot can be saved in LL files To browse LL files a user can use LLview13 exe file which is placed on the disk in main CP System folder e g C CadProfi xx Example Export data to xls format Excel with keeping formatting e A user should select printing to Microsoft Excel format a Microsoft Excel Format v Options for the export module e Additionally he should specify options of module of data export Excel Export Options Please adjust the settings for the XLS export JPEGs Output Output pat All pages into one table In order to export with keeping formatting a user should turn off the Ex port data only from objects of a table option Export data to xls format without keeping formatting e A user should select printing to Microsoft Excel format e Additionally he should specify options of module of export data In order to export data only without keeping formatting a user should mark the Export data only from objects of a table option In order to create a drawing legend or specification using Specification Wiz ard a user should press the Draw
150. way as other objects described in details on the page 46 Lighting amp Search E Detais Lighting Name Lenath X Width Y Height Z Producer Lighting C Binding light double 140 40 10 Lighting fluorescent lamp ED AGE LIGHT Bining sinde ight MEZZO TCL 653 354 AGE LIGHT Binding light double Binding light triple Binding light quadruple Binding single built in light Binding light dual built in OPTIMA 304 2x36W BRILUX Binding built in light triple MARENA 218 18W BRILUX Binding built in light x4 MARENA 236 36W BRILUX Binding light of raster MARENA 258 58w BRILUX Binding light with protective grid C THORN S E Other Gevso Philips E POLAM REM i CG Binding industral 133 Ex 218W 732 POLAMAEt S E Binding for builtin 147 218W 67 4 POLAMREt 8 E Binding type downlights 147 236W 1284 POLAMREL Binding FAREL 147 258W 158 4 POLAM AEt eG Binding extemal 203 2x18W 752 POLAMAE S Binding hanging ceiling aana aeaa aana lt RUBIN Plus PPS 2x18W 63 9 33 7 AGE LIGHT 8 5 AGE LIGHT C Sot View and insertion point Parameters Insertion point System Om Length Width Height Level RUBIN Plus PPS 2x36 Current unit centimetres Switchgears In CP System there are many types of cabinets and distribu gt tors It is also possible to specify user s dimensions of cabinets se iad z p view and their types NKVS2 1100 SV Switchgears are used in the Front view same wa
151. www jl systems dk Introduction About CAD Profi programs Electric schemas 74 Cable trays 76 Lighting and other objects 77 Lighting 77 Switchgears 77 Architecture 78 Walls 78 Defining and editing user s walls 80 Architectural woodwork parametrical objects 82 Furniture equipment 83 Symbols and marks 83 Mechanics 84 Parts 84 Steel shapes 86 Symbols and marks 89 General commands 90 Manufacturers libraries 90 Command 2D 3D 91 Attributes and descriptions 92 Defining and using additional parameters 95 Drawing frames and tables 96 Numbering of objects 97 Specifications 101 Using additional parameters 101 Options of specifications 102 Printing data 105 Layers in CP System 108 Show 2D 3D layers Show all layers 110 Freeze layer groups Thaw layer groups 110 Extending contents of the program 111 Extending databases of the program 111 Adding blocks to library 112 Edition of data in libraries 115 List of 2D fittings 118 Rectangular fittings 120 Round fittings 128 Flex pipes 136 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Introduction About CAD Profi programs Introduction About CAD Profi programs CAD Profi software consists of programs CP Manufacturers CP Symbols and CP System CP Manufacturers the program is a kind of electronic catalogues that contain libraries of blocks of known manufacturers It is distributed by manufacturers o
152. xisting file is specified then data will be added to existing data In order to create summary specification a user should start the Specifica tions command in every drawing select the same template and save data to the same file The Open data button is used to print data from a tempo rary file The temporary file has structure that is compatible with csv format so this file can be used to export data to MS Excel or to MS Access databases Data of CP System can be exported to various file formats xls pdf rtf The way of exporting is described in a further part of this chapter Selecting objects to a specification After pressing the Next gt button a user should select objects that are to be considered in a specification All CAD methods can be used to select ob jects CP System filters selected objects For instance when creating speci fications for symbols CP System selects only symbols After a user has selected objects a window that contain obtained data is displayed P2 njis Bi 103 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Specifications Window of data Sorting data setting the width of columns in plots as well as removing selected rows or hiding redundant columns is possible in a window In order to sort data a user should
153. xts of numbers depends on height target scale of plot and the unit of designing After a user has specified settings of numbering he should select objects as well as the position of texts with numbers In order to finish numbering a user should press the ENTER or Esc buttons After starting numbering it is possible to number objects that can be as signed to a given sequence of numbering It means that if a user starts num bering for example outlets then he can only use pipes fittings and objects of outlets to finish the command In order to number other installations he should start again the Numbering command In case of selecting an object that does not belong to a given sequence of numbering or a selected object has already got a number then the following message is displayed in the command line e g gt Object is not compatible with previously selected object gt This object has already got a number 1 98 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk General commands Numbering of objects 1 W2 W3 l 5 2 1 W 5 An example of various sequences of numbers in one drawing Removing numbers During numbering numbers are assigned to objects Additionally texts of numbers with a leader if necessary are inserted An assigned number is stored directly in an object Removing the text with a number will not cause a number from an object to be removed Therefore the
154. y as other parametrical objects in CP System Detailed description of parametrical objects is on the page 46 77 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk Architecture Walls Architecture CP System Architecture is intended for designers of trade installations This module is sufficient supplement to design or edit building plans much faster Architects can treat it as a basic program which allows to create architectural documentation using walls as well as other elements more quickly and easy After installing CP System a default unit is Bos mm Most architectural projects are de signed in cm In order to change the unit a user should start the CAD Profi Options command and mark centimeters button millimetres O centimetres O metres Sets the global linetype scale factor for unit variable _Itscale Walls A user can draw single layer walls or structural walls in CP System program During starting designing in CP System it is necessary to define a required materials or structural elements of walls because of very big variety of mate rials used in buildings It is also possible to save definitions of structural walls which a user will use in his projects t xk amp E o m gt SG Walls by material Examples B Concrete W Bricks W Clinker Air brick Expanded polystyrene E Mineral wool Walls by purpose Examples
155. y dimensions for parametrical objects Parametrical armature is available in the Parametrical armature com mand The armature similarly to parametrical objects displays real views of devices armature pipe equipments flanges pumps in in line system etc These objects can be inserted in 2D pipes Objects from manufacturers libraries are available in the Products li brary and Previous library commands Products libraries were created together with manufacturers of devices Therefore they contain extensive and current source of objects blocks used during designing Products libraries are being updated all the time and are offered by manufacturers also in the Internet After a user has installed CP System program he can install new libraries which will be added automatically to the structure of the program It can happen that similar devices often can be found in different libraries or commands in CP System For example pumps are in commands Paramet rical objects Parametrical armature and Products libraries If a user wants to insert views of devices in a project he should use rules presented on examples of various pumps e Wilo Stratos 40 1 8 pump Wilo catalogue is in manufacturers libraries so a user should look for pumps in manufacturers libraries e X company pump that can be built on pipes Unless X company is in manufacturers libraries a user should look for the pump in the Para metrical armature
156. ymmetric A 100 C 500x500 R 100 60 Asymmetric R 150 C 500x500 R 100 90 H Filter Set filter If a button Filter is checked only main dimensions e g diameter of a fitting are displayed To display all elements a user should uncheck the button e To turn off filtering a user should uncheck the Filter option O e To establish user s criteria of filtering a button Set filter should b pressed 55 JL Systems Group Slottsmollan 302 31 Halmstad Sverige Tel 46 35 7777030 www jl systems dk HVAC Electrics Pipes ducts cable trays and fittings Dimensions A user can draw fittings with any dimensions In order to do this a user should select an option in the Manufacturer field While a user is drawing using his own dimen sions the fields in which he can enter re quired dimensions are active He can also select typical dimensions All dimensions are visible on miniatures of particular elements Therefore only exem plary dimensions and options will be de scribed Cross section for fittings A user should specify diameter D D2 for round Bi Dimensions fittings For rectangular ones width A A2 as well ae as height B B2 should be specified 20 a 80 CP System creates 2D drawings However a de a signer should specify correct heights of fittings It is necessary to get correct data for subsequent specifi cati

Download Pdf Manuals