Home
USER GUIDE Concens C3CONxW Actuator controller for up
Contents
1. ations may arise which require a particular action These situations are described below Low battery level If the battery level goes below a warning level while operating the actuators three short buzzer tones are sounded This means that the battery requires recharging and the actuators can therefore only be driven in one direction normally in Flat battery If the battery level goes below a minimum level while operating the actuators one short buzzer tone is sounded The actuators will stop immediately and the controller will shut down The battery must be charged You must wait at least one minute before inserting a new battery into the controller If you are using actuators with position feedback hall effect you will need to perform 0 point calibration See section 4 below Extreme battery load The battery may become too hot if it is subject to extreme load due to repeated operations in rapid succession thereby activating the battery s safety thermostat The controller will shut down and the battery must be allowed to cool for at least half an hour before being used again You must wait at least one minute before inserting a different battery into the controller If you are using actuators with position feedback hall effect you will need to perform 0 point calibration See section 4 below NB An alarm only sounds during operation of the actuators No alarm will sound while the system is inactive even if the battery is close to re
2. concense excellent electric actuators USER GUIDE Concens C3CONxW Actuator controller for up to 4 actuators Rev 01 July 2012 Concens A S resundsvej 7 T 45 7011 1131 www concens com DK 6715 Esbjerg N F 45 7610 5010 info concens com Denmark VAT DK10132266 concense excellent electric actuators 1 Contents 2 VTM eee AA ceweacueasncanecasetaneoacscasuraeme sen someone yaa A 2 gt WROD Al NNN 2 4 VON 3 FRE gt RER EE REE EE SE ENE NE EN EEE 4 TN 4 2 Introduction The Concens C3 series is a range of battery based actuator controllers developed especially for mobile applications The controller can manage up to 4 actuators and may be used with a wired or wireless remote control This manual describes the models which have a wired remote control W models The controller may be configured using PC software which may be ordered separately from Concens This allows patterns of operation stroke length speed etc for the connected actuators to be adjusted 3 Preparation Before the system may be used the battery must be charged using the accompanying charger It takes 5 8 hours to fully charge a battery Battery mounted in charger The yellow LED lights up when the charger is connected to power Place the battery in the charger by sliding it in and rotating it until it is pulled into place by the magnets The green LED will flash at approx 1 second intervals while the battery is being charged Once charging i
3. oller sounds a beep when the battery is inserted e lf the actuators cannot be operated perform a 0 point calibration as explained in section 4 The following table lists the alarms which can be sounded by the controller what causes them and the action required in each situation Note the waiting times in the right column as it is important that these are observed Alarm Voltage Description Buzzer tones Operation Wait before level inserting battery ALI 23V_ Insert battery Not possible Limit to permitted operation None Not possible gt prg seconds Caa mo PRAAT oraa RT 17 6V operation 3 x short drive i in gt 30 poem as er um ng an 17 6V Insert battery 3 x short Not possible gt 30 seconds s av shutdown tast _smutscown gt minute gt Shutdown 1 x short shuts down gt I minute If none of the above resolve the problem please contact the supplier User Guide C3CONxW Rev 01 Page 4 of 4
4. ore the position and the controller will have to be 0 point calibrated again e lf the battery s safety thermostat is activated due to overload the battery must be allowed to cool for at least half an hour before being used again A new battery may be inserted into the controller after one minute e f two or more actuators which operate in parallel become misaligned the controller will automatically shut them down It will then be necessary to perform 0 point calibration again as described in section 4 Batteries e Always use batteries which are in good condition and fully charged when inserted into the controller e You can extend the lifetime of the battery by occasionally recharging it even though it is not fully discharged e lf the battery level drops below the critical level and the system shuts down you must wait at least one minute before inserting a different battery and using the system again e If the system is not to be used for an extended period several days or weeks the battery should be removed from the controller to avoid deep discharge which can cause lasting damage to it Handling e Avoid getting metal shavings or other magnetic objects on the battery poles or in the controller 6 Troubleshooting If problems or irregularities arise you should go through the points below in consultation with a technician where appropriate e Check that all connectors are correctly attached to the controller e Check that the contr
5. quiring recharging It is therefore recommended that you always keep a charged battery on hand when using the system 0 point calibration If you use actuators with position feedback hall effect you will need to perform 0 point calibration on the controller so that the innermost position of the actuators can be recorded This must be done for all actuators which use position feedback The controller will sound two long buzzer tones following the beep when the battery is inserted if O point calibration is required It is also possible to initiate manual 0 point calibration by holding in both buttons for the relevant actuator s for 12 seconds The controller sounds a beep followed by 2 long buzzer tones and 0 point calibration can be performed by pressing the in button and holding it so that the given actuator s is are driven in Hold down the button until the actuators have been driven fully in The controller has now been 0 point calibrated and the system may be used normally The actuators can only be driven in during 0 point calibration User Guide C3CONxW Rev 01 Page 3 of 4 concense excellent electric actuators 5 Tips It is recommended that you follow the tips below to achieve the best results and avoid problems in daily operation General e Always wait at least two seconds after the last actuator has stopped before removing the battery from the controller Otherwise controllers using position feedback may not have time to st
6. s complete the green LED remains permanently lit Remove the battery by rotating it 90 degrees It will then be ejected and be ready for use Once the battery is fully charged insert it into the controller Follow the same procedure as for the charger If everything is OK the controller will simply sound a beep three seconds once the battery is in place If the system has any faults the beep will be followed by two or five buzzer tones e 2 long buzzer tones The controller requires 0 point calibration See section 4 below e 5 short buzzer tones The battery must be charged See above It is not possible to operate the actuators The two fault notifications maybe sounded successively if both faults are present User Guide C3CONxW Rev 01 Page 2 of 4 concense excellent electric actuators Battery controller and remote control Battery mounted in the controller ready for use When the battery requires recharging transfer it to the charger as described above It is recommended that you keep an extra battery on hand to avoid disruption to operation Always wait at least two seconds after the last actuator has stopped moving before removing the battery Otherwise the controller may not have time to store the position and it may be necessary to perform O point calibration as described in section 4 4 Normal operation During normal operation the actuator is driven in an out using the appropriate buttons on the remote control Situ
Download Pdf Manuals
Related Search
Related Contents
Hamilton Beach 40616 Use and Care Manual SERIES 6103 Service Manual B Difco™ QC Antigens Shigella Calculer le salaire charnière ou la garantie Attwood 69212T User's Manual Philips CT0892BLK 892 Mobile Phone 2.6" Black Manual de instalación & Modo de Empleo Calentador de piscinas In LG Electronics 37LD345H Flat Panel Television User Manual 安全データシート (MSDS) Copyright © All rights reserved.