Home

Operating Instructions SWINGDOOR Power Drive 1401

image

Contents

1. Instructions MUST be observed Use for the Intended Purpose The TORMAX drive is built using state of the art technology and recognised safety rules it is intended exclusively for use with automatic internal and external doors in pedestrian areas of for example banks restaurants hotels hospitals public build ings historic buildings offices and factory buildings Any other use over and above this use is considered to be not for the purpose in tended and can lead to bodily injury as well as damage to the user s or third party property The manufacturer is not liable for such injury or damage which results from use not for the purpose intended the risk for such events rests solely with the op erator Basic Safety Measures Appropriate Behaviour Only use the system if it is in perfect condition Arrange for malfunctions which can prejudice safety to be rectified immediately by specialist staff Relevant Regulations The operating maintenance and service conditions are to be maintained as di rected by the manufacturer In addition to the operating instructions the relevant legal regulations as well as safety technical and work medical regulations for accident prevention and envi ronment protection of the country in which the door system is operated are also applicable Unauthorized alterations to the system exempt the manufacturer from any liability for resulting damage Operating Instructions SWINGDOOR Power Drive 1401 T 1
2. evident by unusual behaviour of the door and or as a result of an error message on the control panel Error messages appear on the control panel as a flashing E followed by two figures Some malfunctions can be quickly rectified by briefly switching off the power supply to the door drive remember that some models have a battery module If the malfunction cannot be rectified or if it re occurs after a short time you should arrange for it to be rectified by a fitter from your TORMAX dealer In this case note the error number and pass the information to the specialist If the door moves very quickly and in an uncontrolled manner the system MUST be deactivated as described in section 3 4 until the malfunction has been rectified Door Behaviour Action e In spite of the safety sensor the Further operation in all operating modes except OFF or door collides with people OPEN is dangerous and must therefore not be permitted until the malfunction has been rectified by the TORMAX dealer s fitter The door will no longer open au If there is no interruption to the power supply tomatically a Check the position of the operating mode selection switch b Remove any objects from the area scanned by the safety sensor c It is possible that the overheating protection system has been activated Wait for 15 minutes until the tem perature has dropped e The door remains open If there is no interruption to the power supply a Che
3. power supply semi permanently You must ensure that doors on emergency exits can be used as an escape route at all times Components and notices which no longer provide the required safety due to wear or damage must be replaced or repaired by a TORMAX dealer 3 5 Operating Modes Operating Mode OFF The door is held closed by the drive Systems which have an electric door lock are also locked The door will only re open after receiving an impulse from a key switch If the door is changed to the OFF operating mode when it is opening or is already open the hold open time is interrupted and the door immediately closes In the case of double swing doors the door can only be switched to the operating mode OFF when the leaves are overlapped Operating Instructions SWINGDOOR Power Drive 1401 T 1182 e 9 O Operating Mode AUTOMATIC 1 The door can behave differently depending on the settings installed by the installer during commissioning Push and Go If the door is manually pushed in the opening direction it reacts as if to a command to open it opens automatically waits for the hold open time and then closes Time Control If the door receives a valid impulse it opens waits for the hold open time and then closes E Step Control If the door receives a valid impulse it opens and remains open lt closes immedi ately at the next valid impulse Systems with an Electric Door Lock 4 The lock unlocks at every va
4. specialist training and experience and are sufficiently fa miliar with the relevant accident prevention regulations Health and Safety Regula tions guide lines and generally acknowledged rules of technology with the result that they are capable of assessing the safety condition of power driven doors Such groups of people include for example specialist staff of the manufacturing or sup plying company and persons with appropriate experience employed by the opera tor Specialist staff must provide their assessment objectively from the standpoint of accident prevention and must not be influenced by other e g economic factors Repairs on electrical components must be performed by a specialist electrician who must work in accordance with the relevant regulations the power supply either by removing the power plug or by a system switch with a A If any work is being carried out on the door the door must be visibly isolated from lockable OFF position Scope of Maintenance Work The maintenance work which must be carried out is listed in the system test book The findings of the inspections must be entered along with the date and the signa ture of the person carrying out the inspection 12 Operating Instructions SWINGDOOR Power Drive 1401 T 1182 e 4 2 Inspections by the System Operator Scope of the Inspection The operator of an automatic door system must check all functions of the auto matic door and the safety devices at regula
5. 182 e 5 2 2 Organisational Measures General Doors are to be operated and maintained in such a way that the safety of users maintenance personnel or a third party is ensured at all times area these features must not be deactivated so that the door can continue to be used Servicing TORMAX Door Systems The necessary instructions Operating Instructions must be available to all persons who operate check or maintain the doors A If malfunctions occur in safety facilities e g safety sensors for monitoring the swing Personnel directed to carry out any activity on the door must have first read and understood the Operating Instructions Mechanical and electrical work on the door system and its controls may only be carried out by skilled staff or by specialists from TORMAX dealer All other persons are prohibited from carrying out repairs or modifications on the system Designations Notices on doors and switch gear must be clearly legible easily understood and durable Information necessary to ensure personal safety marking of the escape routes and for maintenance purposes must be displayed 2 3 Safety Devices Following a hazard analysis TORMAX has provided appropriate safety devices in the control system of this type of drive to protect against bodily injury and material damage These devices must be state of the art and comply with the Machinery Directive 98 37 EEC CEN and CENELEC standards and the corresponding na tional
6. 82 e 7 3 Operation 3 1 Commissioning AN Unlock the mechanical lock if fitted Switching on Systems without an operating mode switch e Switch on the power supply power plug and or system switch Systems with an operating mode switch 4 e Switch on the power supply power plug and or system switch Select the required operating mode on the operating mode switch e g AUTOMATIC Recommissioning If a door is taken out of commission for a lengthy period it must be checked as in Section 4 2 prior to being recommissioned and if necessary repaired to ensure that the safety of persons is always assured 3 2 Function in Normal Operations The TORMAX door drive opens and closes the door automatically The user can influence the door s behaviour by the selection of the operating mode on the operation mode switch 4 see section 3 5 The operating mode OFF must be se lected before locking the door mechanically Triggering the Opening Movement of the Door The door is prompted to open automatically by opening activators such as e Sensors 4 motion detectors 4 contact mats etc or manually e with Push and Go buttons 4 key switches manual switches etc Safety Devices Door systems may only be operated if all safety devices are available and opera tional 3 3 Function in the Event of a Power Failure In the event of a power failure the door is moved into the pre defined end position open or clos
7. IO A TORMAX AUTOMATIC T 1182 e 10 06 Operating Instructions for automatic swing doors SWINGDOOR Power Drive 1401 Contents 1 About these Instructions 4 2 Safety 5 5 6 6 2 1 General Safety and Accident Prevention Instructions 2 2 Organisational Measures 2 3 Safety Devices 3 Operation 8 3 1 Commissioning 8 3 2 Function in Normal Operations 8 3 3 Function in the Event of a Power Failure 8 3 4 Decommissioning 9 3 5 Operating Modes 9 1 3 6 Resetting the Panic Fitting 1 4 Maintenance 12 4 1 Periodic Maintenance 12 4 2 Inspections by the System Operator 13 5 Trouble Shooting 16 6 Additional Information 17 6 1 Technical Data 17 6 2 Warranty Claims 17 6 3 Optional Extras 17 6 4 Disposal 17 First issued 5 06 Update 10 06 Printed on environmentally friendly paper which was bleached using a chlorine free process Landert Motoren AG and Landert GmbH are certified to ISO 9001 Operating Instructions SWINGDOOR Power Drive 1401 T 1182 e 3 1 About these Instructions Adressee Status These instructions are intended for operators and users of automatic TORMAX door system they assume that the system was installed and tested by specialist staff and is therefore ready for operation Area of Application This document applies to swing doors with TORMAX automatic opening systems type SWINGDOOR Power Drive 1401 Explanation of Symbols We have marked all passages in these Operating Instructions relating t
8. ce more Er SOSE T1134 6 T1134 7 UL NY 14 Operating Instructions SWINGDOOR Power Drive 1401 T 1182 e Safety Facilities in Opening and Closing Direction The safety sensor system etc Checks Place an obstruction in the swing area of the door gt The door reverses before it encounters the obstruction T1134 8 Safety Facilitiy for the Swing Area Reflective light scanner 4 safety contact mat 4 etc Checks e Activate the safety device in the swing area when the door is closed gt The door remains closed e Activate the safety device in the swing area when the door is open gt The door remains open T1134 9 If the door is already in motion its movement is not interrupted by the safety de vices for the swing area Panic Fitting Checks Separate the drive from the power supply system switch power plug or by using the operating mode switch Select operating mode OFF Push the door in the opposite direction to the opening direction and release the panic fitting e Push the door leaves back into the exit position Checking the System for Signs of Excessive Wear Checks e Examine the surfaces of the door system visually for recognisable damage and defects e Listen for unusual noises when the door is moving Operating Instructions SWINGDOOR Power Drive 1401 T 1182e 15 5 Trouble Shooting Malfunctions become
9. ck the position of the operating mode selection switch b Remove any objects from the area scanned by the safety sensor or the opening activator c If your door system is programmed to open in the event of a power failure it is possible that the overheating protection system has been activated Wait for 15 minutes until the temperature has dropped e Reset of error message Press one of the selection buttons of the control panel to reset an error message 16 Operating Instructions SWINGDOOR Power Drive 1401 T 1182 e 6 Additional Information 6 1 Technical Data Mains connection 1x230VAC 1x115VAC Frequency 50 60 Hz Power consumption 4 250W Protective system drive IP 67 7 days water up to the upper edge of the case Protective sys control box IP 55 Temperature range 20 C to 50 C Opening angle 0 to 99 Drive marking CE Equivalent continuous sound pressure level lt 70 dB A Power supply to sensor 24VDC 0 8A Power supply to lock 24 VDC 1A Application category 1 3 1 0 123 2 DIN 18650 1 2005 12 6 2 Warranty Claims Malicious or wilful damage to and contamination of system components as well as modifications to the drive and control system by third parties renders all warranty claims null and void 6 3 Optional Extras The following are some of the optional extras which are available electro magnetic lock key switch security featu
10. ed by the spring incorporated into the drive 8 Operating Instructions SWINGDOOR Power Drive 1401 T 1182 e Emergency Opening Closing The automatic door can be activated manually without altering the operating mode Emergency Power Supply battery module The emergency power supply will continue to operate the door in the pre set operat ing mode for a limited period The emergency power supply is automatically switched off when the batteries have been exhausted The door operates as normal without further intervention when power is restored the batteries are automatically re charged Further information is contained in the Operating Instructions for the battery module 3 4 Decommissioning Monitoring The TORMAX processor control system monitors a large number of the door s func tions and displays malfunctions on the control panel 4 see Trouble Shooting in section 5 If the malfunction is relevant to safety the control system automatically places the door drive in a safe condition Deactivation in the Event of a Malfunction Door drives must be deactivated as soon as malfunctions or faults occur which prejudice the safety of persons You must arrange for the malfunctions of defects to be rectified immediately by qualified staff The door is deactivated by switching off the power supply Doors may only be approved for re use if the fault has been rectified repair or the danger removed the drive separated from the
11. lid opening impulse The door lock must be manually unlocked with the door button before it is possible to open the door with the Push and Go system Operating Mode AUTOMATIC 2 Corresponds to operating mode AUTOMATIC 1 but a different sequence of move ments can be set by the installer during commissioning e g a slower opening movement different open positions and a longer hold open time oO Operating Mode EXIT The door only opens on receipt of an impulse from inside or a key switch impulse The external activator is also disregarded when the door is open The door behaviour is determined by the last operating mode selected AUTOMATIC 1 or AUTOMATIC 2 O Operating Mode OPEN The door is opened by the drive and permanently held in the open position The open position is determined by the last operating mode selected AUTOMATIC 1 or AUTOMATIC 2 P Additional Operating Mode P MANUAL OPERATION The additional operating mode P is freely programmable by the installer MANUAL OPERATION is active without programming the door can be freely moved and opened manually This operating mode is primarily suitable for cleaning the door leaf 10 Operating Instructions SWINGDOOR Power Drive 1401 T 1182 e Altering the Operating Mode Doors fitted with drives but without an operating mode selection switch 4 or a con trol panel 4 are set to operating mode AUTOMATIC 1 Operating Mode Selection Switch Control Panel 4 Symbols for LED
12. o your safety with this symbol gt gt This symbol warns you about electric currents In order to ensure that the door system functions perfectly you MUST be sure to follow the instructions in text which is highlighted in grey Failure to do so can result in damage Functions marked with this symbol correspond to the basic settings However they can be reprogrammed by installation staff This symbol indicates optional components which are not installed in all systems Operating Mode Symbols Operating mode OFF Operating mode AUTOMATIC 1 Operating mode AUTOMATIC 2 Operating mode EXIT Operating mode OPEN 09600 a Operating mode MANUAL OPERATION Languages These Instructions are available in various languages Please enquire at your TORMAX dealer Other Applicable Documents The tests which must be carried out during the system s periodic checks are listed in the system test book see Section 4 1 for further information The test book should be kept close to the relevant door System test book T 879 e 4 Operating Instructions SWINGDOOR Power Drive 1401 T 1182 e 2 Safety 2 1 General Safety and Accident Prevention Instructions The Operating Instructions and particularly the following safety instructions must be carefully read and observed prior to commissioning Instructions to which your attention is specially drawn see Section 1 for explanations of the symbols in these Operating
13. r intervals and at least every 3 months in order to ensure that malfunctions or changes in the system prejudicial to safety are recognised at an early stage If malfunctions should be recognised during these periodic inspections you must arrange for these to be rectified immediately by a TORMAX dealer see the rear side of these Operating Instructions for the address When conducting this inspection always bear in mind that a switching error in the system is possible If there is inadequate clearance available no part of the body should be used to test the functions a piece of wood rubber or similar material should be used instead The inspection work to be undertaken by the operator requires very little time but is essential to ensure that the system is operating perfectly and safely The inspection work to be undertaken by the operator consists of Checking the Opening Activators If there is an operating mode switch available e Set operating mode AUTOMATIC 1 Automatic Opening Activators radar or infra red motion sensors 4 contact mats 4 etc Check A a il Approach the door in the normal way gt The door opens at the correct time and closes after the set hold open time 71134 3 Check e Approach the door slowly like older per Ka as sons with a short pause before reaching x the door approximately 5 seconds gt The door open
14. requirements Electronic Reversing An electronic switch monitors the door when it is closing and opening If the door encounters an obstruction when opening it stops for a short period and then closes If it encounters an obstruction when closing it waits for the safety period and then attempts to close once again The reversing movement can be switched off by the installer 6 Operating Instructions SWINGDOOR Power Drive 1401 T 1182 e External Safety Devices Safety in the Opening Direction 4 safety sensor system etc The safety device on the door leaf which moves with the leaf recognises persons or objects in the door leaf s opening area The opening movement is immediately interrupted and the door closes when the safety system is activated Safety in the Closing Direction 4 safety sensor system etc The safety device on the door leaf which moves with the leaf recognises persons or objects in the door leaf s closing area The door immediately opens waits for the safety period and then closes again when the safety system is activated Safety for the Swing Area 4 safety reflective light scanner safety mat etc The safety device recognises persons or objects in the door s swing area The door is prevented from moving if a safety device has been activated If the door is already moving the opening or closing movement which has already started is completed Operating Instructions SWINGDOOR Power Drive 1401 T 11
15. res and a range of activators Please ask your TORMAX dealer for more information 6 4 Disposal This system must be properly dismantled at the end of its working life and its disposal carried out in ac cordance with national regulations We recommend a that you contact a specialist disposal company Before opening the case remove the tension on the spring right up to the stop as in the drawing Contents subject to technical changes Operating Instructions SWINGDOOR Power Drive 1401 T 1182e 17 IO TO p M AX Your first choice for automatic doors AUTOMATIC TORMAX SLIDEDOOR TORMAX SWINGDOOR TORMAX FOLDDOOR TORMAX REVOLVEDOOR Manufacturer Advice sales installation Repairs and service TORMAX CH 8180 B lach Z rich Phone 41 0 44 863 51 11 Fax 41 0 44 861 14 74 Homepage www tormax com E Mail info tormax com TORMAX is a Division and a registered trade mark of Landert Motoren AG
16. s operating mode Selection OFF button 1 upwards AUTOMATIC1 Door electrically A locked AUTOMATIC2 CE TORMAX wae __ Additional operating EXIT ne O Selection OPEN www tormax com button 2 111822 e downwards The control panel can display causes of malfunctions as well as the operating mode see section 5 Control Panel Lock 4 The control panel can be protected against mis use by an external key switch Any change to the settings by means of the control panel is therefore prevented 3 6 Resetting the Panic Fitting 4 Separate the drive from the power supply system switch power plug or with the operating mode switch Select operating mode OFF e Push the door leaves back into the initial position Operating Instructions SWINGDOOR Power Drive 1401 T 1182e 11 4 Maintenance The responsibilities of maintenance personnel must be clearly defined AN Keep hands or other parts of the body well away from moving parts Spare parts must meet the manufacturer s technical requirements Only genuine TORMAX spare parts must be used 4 1 Periodic Maintenance Maintenance Interval The maintenance interval is determined with regard to the frequency of use However maintenance work must be carried out by specialist staff at least once per year Requirements for Maintenance Personnel Specialist staff are persons who possess sufficient knowledge in the field of powered doors as a result of their
17. s normally even when approached slowly The door must not close pi i 2 prematurely YA gt Operating Instructions SWINGDOOR Power Drive 1401 T 1182e 13 Inspection of the Manual Opening Activators Push Buttons 4 Key Switch 4 etc Checks on time control systems 17 e Operate the corresponding activator briefly a gt The door opens and closes after the pre _ set hold open time u T1134 5 1 e Operate the activator for about 20 sec onds gt The door opens and remains open When the activatoris no longer operated the door closes after the pre set hold open time Checks on step control systems Trigger the corresponding activator briefly gt The door opens closes and remains in the OPEN position CLOSED position until the activator is triggered once more Inspection of the Safety Facilities The safety devices have a higher priority than the activators this aspect must be kept in mind and checked during the following inspection procedures Electronic Reversing if the reversing system was switched off by the installer this inspection procedure does not apply Check Place an obstruction in the opening area and then in the closing area gt After the door has encountered the obstruction when opening it stands still for a short time and then closes again gt After the door has encountered the obstruction when closing it opens again waits for the safety time and then tries to close on