Home

DM1210N Manual - Pacific Micro Systems

image

Contents

1. O C Output 1 2 Normal Ov O C Output 1 2 Inverted Ov Using the internal open collector transistor max sink current is 100mA SOFTWARE UPGRADES Upgrading DM1210N Software e Connect the DM1210N to the PC via the Network connector e Run DMxxConfig exe e Click Search for DM1210N s e Selected the DM1210N to upgrade from the list box e Click on Utilities e Select Upgrade Software e Select the upgrade file to upload to the DM1210N e Click Go to upload the file DM1210N Pacific Micro Systems
2. 64 4 475 9084 PO Box 9285 Mobile 64 25 449 061 Wellington 6012 Email trevor pacmicro com NEW ZEALAND Internet www pacmicro com DM1210N O Pacific Micro Systems OUTLINE This Data Multiplexer DM1210N receives data from a number of different Satellite Navigators GPS s Lorans etc capable of sending NMEA0182 3 Furuno CIF JRC format Koden 8805 8811 Kaijo Denki format or Simrad EK500 depth format These can be converted to NMEA0183 and transferred to any other output The data can also be input and output on an UTP 10Meg Ethernet port Features 1 Ethernet port 10Mb UDP 12 Current Loop RS422 or RS232 asynchronous serial Inputs 10 Serial Outputs 10 x Current Loop or RS422 asynchronous serial Outputs 4 of the 10 also have RS232 asynchronous serial Outputs User selectable baud rates to allow high thru put of data Conversion of NMEA0183 Furuno CIF to NMEA0183 or Furuno CIF serial data Full transfer capabilities between all Inputs amp Outputs allowing flexible data combining Filtering of NMEA 0183 data thru any input or output ie All GGA VTG ZDA etc NMEA0183 or Furuno CIF sentences can be generated from trigger and depth pulses with selectable NMEA0183 depth sentence ie SDDBT SDDBS etc Output in Meters Fathoms or Feet depth output with selectable sound velocity factors between 1450 and 1550 m s Convert Simrad ITI net position to TLL sentence for display on plotter Convert Furuno Sonar target data to TTM sentence
3. for display on plotter Capability to change NMEA0183 talkers on any outputs Generates log pulses from NMEA0183 sentence VTG or VHW in 100 200 or 400 PPNM Generates NMEA0183 sentence VTG or VHW from 100 200 or 400 PPNM input Alarm output when predefined conditions are met ie No GPS No DGPS etc Galvanic isolation between input supply data inputs and outputs RFI shielded housing Status LEDs on all inputs and outputs 4 x binary inputs outputs DM1210N Pacific Micro Systems PARTS SUPPLIED 1x DM1210N Interface Pacific Micro Systems DM1210N INSTALLATION 1 Run a two core screened data cable from each serial source to the required serial input 2 Run a two core screened data cable from each output to the data destinations 3 Run a standard UTP Cat5 patch cable crossover between the DM1210N Network port and the network port on the target PC or a straight thru cable to a hub that the PC is also plugged in to 4 Run the supply cable to a suitable 11 35v supply Red Black volts Black volts Note The DM1210N has DC isolation between its power supply input and ground This makes it suitable for interfacing to any computer installation and all isolated ground equipment without affecting the integrity of the battery positive or negative relative to ground DM1210N O Pacific Micro Systems DM1210N OPERATION 1 The RX LED s are normally off and flashing on when receiving serial d
4. DATA MULTIPLEXER DM1210N Operation and Installation Manual O Pacific Micro Systems LIMITED WARRANTY Pacific Micro Systems warrants its products to be free from defects in materials and workmanship for a period of one year from date of sale to the original owner or fifteen months from date of sale from Pacific Micro Systems This warranty provides for the repair or replacement at our option of any parts found to be defective in normal and intended use provided that such defects are in our opinion due to faulty material or workmanship This warranty does not apply to products which have been improperly installed subjected to extremes beyond the limits of our specifications or which have been physically damaged Nor does it apply to products found to be defective due to abuse lightning or any other electrical discharge salt or fresh water spray or improper or unauthorised repair Pacific Micro Systems will pay shipping method to be of our choice and insurance for return of said product provided that the returned product proved defective under the terms and conditions of this warranty The obligation of Pacific Micro Systems shall be limited to the repair or replacement only In no event shall Pacific Micro Systems be liable for any special collateral incidental or consequential damages for 1 breach of any provisions hereof including without limitation provisions regarding warranties guarantees and or indemnities or 2
5. any claims by the purchaser concerning the goods without limitation claims of loss of goodwill loss of profit or revenues loss of use cost of removal installation or reinstallation personal injury of any kind to the purchaser or anyone else The forgoing warranty is in lieu of all other warranties whether expressed or implied or arising by law custom or conduct including without limitation the warranties of merchantability and or fitness for any particular purpose Pacific Micro Systems policy is one of continued development For this reason Pacific Micro Systems reserves the right to change specifications without notice and without incurring any obligation to similarly alter products previously purchased Copyright O 1992 2007 Pacific Micro Systems All rights reserved No part of this manual or software whether on disk or in hardware supplied by Pacific Micro Systems may be reproduced in any form without the express written permission of Pacific Micro Systems DM1210N O Pacific Micro Systems Version 1 01 1 September 2007 Contents Page OUTLINES 2 O 1 PARTS SUPPLIED occ Ng aaa Na Ng aa 2 INSTALLATION 5 ist 2 DMI210N OPERATION ss ee open ica 3 DMxxConfig EXE DM1210N CONFIGURATION 3 SPECIFICATION Sn e Ge ei 4 CONNECTION DE PAILS tics snang e Na aaa a nan usa n seo ae 5 SOFTWARE UPGRADES ioana oa a aa i a 8 Designed and manufactured by Pacific Micro Systems Telephone 64 4 475 9004 136 Curtis Street Facsimile
6. ata 2 As data is received in 1 thru 12 the appropriate RX LED will flash 3 As data is transmitted out 1 thru 10 the appropriate TX LED will flash DMxxConfig EXE__ DM1210N CONFIGURATION Due to the extensive capabilities available in the DM1210N configuration is accomplished though the Configuration program DMxxConfig exe Connect the DM1210N Network port to the PC network port via a cross over cable or standard cable and network hub and launch the program DMxxConfig EXE Click on the button Search for DM1210N s All DM1210N s on the network will be listed in the list box Highlight the DM1210N Serial Number and IP Address of the DM1210N to configure Click on the Get Config menu item to get the selected DM1210N s current configuration Change the configuration as required using the Options and Transfer Menu Items Update the DM1210N by clicking on the Update Config Menu Item DM1210N O Pacific Micro Systems SPECIFICATIONS Serial data capabilities Inputs 1 thru 12 RS232 or Current Loop RS422 Outputs 1 thru 10 Current Loop orRS422 Outputs 7 thru 10 RS232 Input Output 1 Baud Rate up to 115200 Input Output 2 thru 10 Baud Rate up to 38400 Input 11 12 Baud Rate up to 38400 Serial Formats Received NMEA0183 Furuno CIF Serial Format Transmitted NMEAO0183 CIF Transmitted Data NMEA0183 4800 8 data bits no parity 1 stop bit CIF 4800 7 data bits even parity 2 stop bits Use
7. r 50 115200 5 8 data bits None Odd Even parity 1 or 2 stop bits Digital In 0 5v Digital Out Current sink 100mA External supply required 50v max Power Requirements 11 35 vdc 50 200 mA DC isolation between power supply input and ground is provided Weight 620 grams Dimensions 170 x 150 x 40 mm Mounting Table top or wall mounted Pacific Micro Systems has a policy of continued development and therefore reserves the right to change specifications without notice DM1210N O Pacific Micro Systems CONNECTION DETAILS ve DC In 11 36 Ground 2 ve DC In 11 36 Current Loop Input RXI Signal Current Loop Input RX Return Current Loop Input RX2 Signal Current Loop Input RX2 Return Current Loop Input RX3 Signal Current Loop Input RX3 Return Current Loop Input RX4 Signal Current Loop Input RX6 Return Current Loop Input RX9 Return C DM1210N O Pacific Micro Systems CONNECTION DETAILS cont Description Current Loop Input RX12 Return Description Ground RSA422 Output TX3 Ground DM1210N O Pacific Micro Systems CONNECTION DETAILS cont Description RS232 Output TX7 RS232 Output TX8 Ground RS422 DATA OUTPUT POLARITY Sy RS422 TX OV DM1210N Pacific Micro Systems 8 5v RS422 TX 0v PPNM Connections Jil Description Analogue Out Analogue Out 2

Download Pdf Manuals

image

Related Search

Related Contents

Active Key AK-B4100    INSTALLATION MANUAL FOR ROTAID SOLID PLUS HEAT  Bedienungsanleitung CombiMaster® Plus  TFC .NET PROYECTO FINAL DE CARRERA Manual de Usuario  User Manual SPListX for SharePoint  アースクリーンK 取扱説明書  PDFファイル  Husqvarna Automobile Parts HUV 4214 User's Manual  Humax CX PVR-9200C DVR User Manual  

Copyright © All rights reserved.
Failed to retrieve file