1. to Auto mode by pressing Off again Lock amp Unlock Press unlock to unlock the presence detector so that the settings can be modified Press lock to lock the presence detector after the settings have been made to save the changed setting For all settings the presence detector must be unlocked the setting selected and the presence detector locked again before the setting is activated If the presence detector is not locked it will lock automatically after 2 minutes and any modified settings will be saved Reset If pressing reset all setting made by the IR Remote will be deleted The presence detector will run according to the setting made on the knobs Test Load will be switched ON for 2 sec every time movement is detected Lux Fixed settings for 10 30 100 400 1000 lux and a user defined lux value Learn actual lux User defined lux value works in the range 10 1000 lux Press the button Learn actual lux until the presence detector s red and green LED s are flashing This means the presence detector has enter into learning mode Learning time is 10sec If the Learn actual lux was successfully it s confirmed by the LED s which goes On Then presence detector returns to Auto mode If Learn actual lux is out of the range of 10 1000 lux the LED s in the presence detector will after 10sec flash quickly for 5sec to Main Office ACelSHOP
2. 1321009508 which will control the load according to it s settings 1321009511 has the same detection range as 1321009508 To get complete coverage when using more sensors it IS recommended to calculate with approx 20 overlap in the in ultrasonic detection range See Fig 3 Main Office ACelSHOP ApS Lille Strandstraede 14 DK 1254 Copenhagen K CVR No 28115067 ACelSHOP ApS Unit 17 Premier Park Acheson Way Trafford Park Manchester M17 1GA Phone 161 874 1486 Fax 161 877 2013 E mail sales acelshop co uk Installation Flush mount with a standard junction box or surface mounted by using the surface mounting base When using the surface mounting base there are 7 pairs of fixing holes with various distances from 41mm to 85mm NOTE The direction of the ultrasonic sensor should aim to the main detection area to achieve the best detection coverage Connection See connection diagram Fig 4 6 After connecting the detector to power it takes approx 30sec for the detector to warm up During this time the load will be switch ON Hereafter the detector will run according to it s settings Limiting the detection range of PIR sensor If the detection range is too large it can be reduced by fitting the enclosed lens mask It makes it possible to reduce the maximum detection range of 8 m to 6 m or 2 m and the angle of 360 can be reduced in steps of 30 Fig 8 Settings The settings can be m
3. ACel DT PIR ULTRASONIC SENSOR IMPORTANT NOTICE This device should be installed by a qualified electrician in accordance with the latest edition of the IEE Wiring Regulations and any applicable Regulations User Manual Operation The presence detector 1324009508 integrates advanced PIR and Ultrasonic technologies in one unit The combination of these technologies helps to eliminate false triggering problems even in difficult applications It is suitable for indoor application which is ideal for using in open plan office multi stall public restroom conference room under ground parking lots classroom library etc By using the knobs on 1324009508 or the IR remote control 1324009524 Accessory the time ultrasonic sensor sensitivity lux sens function compensation for air flow and triggering method can be adjusted Function The presence detector has an integrated light sensor that ensures lighting is only switched on when it detects movement and the daylight level lux level is below the preset level The light stays on as long as movement is detected and the off delay ensures that the light remains switched On for a period after the last detected movement The presence detector can be used with its factory settings or the settings can be modi fied using the remote control IR Remote 1324009524 accessory It is also possible to switch the light On Off with a push button The pus
4. ApS Lille Strandstraede 14 DK 1254 Copenhagen K CVR No 28115067 ACelSHOP ApS Unit 17 Premier Park Acheson Way Trafford Park Manchester M17 1GA Phone 161 874 1486 Fax 161 877 2013 E mail sales acelshop co uk indicate that Learn actual lux was unsuccessfully In that case the following values will be used Lux level is above 1000 lux the presence detector will use 1000 lux as lux setting The presence detector is increase or decrease by 10 which is indicated by the green LED flashing When the sensitivity of presence detector is at its highest or Ultrasonic sensors detects movement In US only mode load will be turned on when Ultrasonic sensors detects movement PIR only lowest level the green LED stays Lux level is below 10 lux the presence detector will use 10 lux as lux setting Memo The Memo button is uses to store and duplicate the values of Timel and Lux 1 Press Unlock at the sensors where the setting should be learned from the sensor must have setting learned via IR remote 2 Press Memo for more than 3 sec to save the settings after 3 sec the green LED will flash as an indication for saved settings 3 Press Lock 4 On the sensor to which the setting shall be transferred press Unlock 5 Press Memo the green LED will flash as an indication for saved settings 6 Press Lock Time 1 and Lux are now transferred T
5. Off delay time is too long 2 Detector has false triggering 3 Incorrect wiring Proposed solution 1 Check the set off delay and adjust it if necessary to a lower value 2 Check for any objects which may cause false triggering and remove them from the detectors range 3 Refer to wiring diagrams See Fig 4 Fig 6 Problem Red LED does not turn on Possible cause 1 PIR is not chose as the triggering method 2 The movement is out of the PIR detection range 3 The lens mask is used an it covers the movement Proposed solution 1 Choose PIR sensor as the triggering method 2 The movement should be in the valid detection range 8m 3 Remove or reposition the lens mask Problem Green LED does not turn on Possible cause 1 Ultrasonic sensor is not chose as the triggering method 2 The movement is out of the detection range Proposed solution 1 Choose ultrasonic sensor as the triggering method 2 The movement should be in the valid detection range 10x16 m Problem False triggering Possible cause There are heat sources airflow highly reflective objects or any objects which may be swayed in the wind within the detection range Proposed solution Avoid aiming the detector toward any heat sources such as air conditioning electric fans heaters or any highly reflective surfaces Make sure there are no swaying objects within the detection range NOTE Effects that might have in
6. fluents on ultrasonic detection Airflow Airflow can cause false triggering of the ultrasonic sensor If air flow is thought to cause false triggering try setting the Sens Knob to ON This function will reduce the sensitivity of ultrasonic sensor approx 10 40 according to the strength of the airflow Sound wave absorbing materials The sensitivity and range can be affected by the materials such as carpet sound absorbable materials curtains etc Wiring A reverse connection in between N and L will cause lower sensitivity of ultrasonic sensor sensitivity and also reduce the detection range Technical data Input Power supply 230 V 10 50 Hz Power consumption Output Relay contact potential free Load Incandescent lamps Fluorescent tubes not Compensated 1200 VA Halogen incandescent lamps 2300 W Energy saving bulbs 58 x 18 W Max compensation capacity 140 uF Max inrush current 165 A 20 m sec Performance Lux range Time delay Detection range Ultrasonic 0 x 16 meter 138 m2 68 meter 50 m2 Installation and ceiling height 2 3 meter Protection degree Insulation class Ambient temperature 0 C 45 C Approvals CE according to NO 230 V u 10 A 2300 W EN 60669 2 1 Main Office ACelSHOP Aps Lille Strandstraede 14 DK 1254 Copenhagen K CVR No 28115067 ACelSHOP ApS Unit 17 Premier Park Acheson Way Trafford Park Manchester M17 1GA Phone 161 874 1486 Fax 161 877 2013 E
7. h button will switch On the light regardless the lux level When the light is switch On with the push button it stays On as long as movement is detected and the Time off delay has not run out If the light is switch Off with the push button it stays Off as long as movement is detected and the off delay has not run out Installation Position The detector responds to movement and heat in relation to its surroundings Avoid positioning the detector close to heat sources such as cookers electric radiators ventilation systems or any moving objects cause by air flow etc Also surfaces that are highly reflective like large window or glass sections can cause unwanted activation Fig 1 It s recommended that the detector is mounted on the ceiling If the detector is mounted suspended from the ceiling the ultrasonic range is decreased Location The recommended installation height of this detector is 2 3m and 2 5m is the optimal mounting height The detection range of PIR sensor can reach up to 8m and ultrasonic sensor is an oval shape of 8m x 10m with small movement 1 e hand wave and an oval shape of 10m x 16m with large movement 1 e walk The detection angle is 360 for both PIR and ultrasonic sensors See Fig 2 Enlarging the detection range By using the presence detector 13240095011 it is possible to enlarge the detection range It is possible to connect up to 2 pcs 1321009511 to one
8. ime For setting the off delay press Time I and then one of the 6 preset settings 1 5 15 30 and 60 minutes as well as Pulse interval of I seconds On 9 sec Off US and US Press US or US to set the sensitivity of ultrasonic sensor Each time one of the buttons are pressed the sensitivity of On for approx 2sec The default sensitivity is 80 Sens Press Sens On or Sens Off to turn the compensation for air flow On or Off Trigger method Setting the triggering method Press the corresponding button PIR US PIR only PIR US or US only This setting is use to select the desired detection method Terminology Trigger method PIR US PIR and US Where a defined detection or detection of minor motion 1s necessary choose this triggering method It can also reduce false triggering problem For example a classroom an open plan office etc Load will turn on when both PIR and Ultrasonic sensors detects movement When load is On either PIR or Ultrasonic detecting movement will keep the load On US only or PIR US PIR or US When there is high level of minor motion or obstacle furniture or partitions existing in the monitored space or it is a multi stall space For example a multi stall public restroom an office with partitions etc In PIR US mode load will be turned on when either PIR or If the monitored space is free of obstacle or has high level of airflow
9. mail sales acelshop co uk Aam JD a oe D 2 Side view Top view al el WI f RI gt Classroom E Conference room L PIR o8ny a ee f arr 16m US 16m 1 23 Ultrasonic Body Motion EZ PIR Body Motion 16 x 10 m Oval 138 m2 8 m 50 m2 Ultrasonic Small Motion M PIR Small Motion 10x8m Oval 66 m2 4 m 12 5 m2 Main Office ACelSHOP ApS Lille Strandstraede 14 DK 1254 Copenhagen K CVR No 28115067 ACelSHOP ApS Unit 17 Premier Park Acheson Way Trafford Park Manchester M17 1GA Phone 161 874 1486 Fax 161 877 2013 E mail sales Q acelshop co uk SRL 12 1324009508 ACel DT PIR Master 20 overlap 1324009508 ACel DT PIR Master 1324009511 ACel DT PIR Slave 1324009508 ACel DT PIR Master NY IO e Meter A Sens PIR only US only LONO IL PIRUS PIR US 230 V HVAC Main Office ACelSHOP ApS Lille Strandstraede 14 DK 1254 Copenhagen K CVR No 28115067 ACelSHOP ApS Unit 17 Premier Park Acheson Way Trafford Park Manchester M17 1GA Phone 161 874 1486 Fax 161 877 2013 E mail sales acelshop co uk Main Office ACelSHOP ApS Lille Strandstraede 14 DK 1254 Copenhagen K CVR No 28115067 ACelSHOP ApS Unit 17 Premier Park Acheson Way Trafford Park Manchester M17 1GA Phone 161 874 1486 Fax 161 877 2013 E mail sales acelshop co uk
10. odified on the knobs below the cover or by using the IR Remote 1324009524 accessory Factory setting Fig 7 Lux 100 lux Time Off delay 15 minutes Meter 80 approx 8 x 13 meter Sens OFF Trigger method PIR US Lux Setting the lux level between 10 and 1000 lux Indications of 10 100 300 and 1000 are approximately Time Setting the off delay This has 6 preset settings 1 5 15 and 30 minutes as well as Pulse interval of 1 seconds On 9 sec Off and test setting Under test Load will be switched ON for 2 sec every time a movement is detected Meter Setting the detection range This has 4 preset settings min setting which is approximately 2 x 3 m 4x6m 7x8 m and max setting which is approximately 10 x 16 m Sens Turning the compensation for air flow On or Off Trigger method Setting the triggering method This has 4 preset settings PIR US PIR US and PIR US This setting is use to select the desired detection method IR Remote Settings when using the IR Remote 1321009524 accessory On amp Off By pressing the On button load will be switched On for 8 hrs It s confirmed by the LED s which will be flashing The presence detector can be returned to Auto mode by pressing On again By pressing the Off button load will be switched Off for 8 hrs It s confirmed by the LED s which will be flashing The presence detector can be returned
11. or the detection area Is needed to be well specified For example a small scale office with air conditioning a small conference room etc In PIR only mode load will be turned on when PIR sensors detects movement The detector is equipped with 2 led s a red and a green The LED s are used to indicate wherever the movement was detected by PIR or ultrasound Red LED indicates PIR and the green indicates ultrasound Sens The sensitivity Sens function is used to reduce the sensitivity against air flow Meter The meter setting is used to reduce the sensitivity of the ultrasonic detection range Time The time setting is used to set the off delay before the load switches OFF after the last detected movement Lux The lux setting is used to set the light level for when below the load can switch ON Main Office ACelSHOP Aps Lille Strandstraede 14 DK 1254 Copenhagen K CVR No 28115067 ACelSHOP ApS Unit 17 Premier Park Acheson Way Trafford Park Manchester M17 1GA Phone 161 874 1486 Fax 161 877 2013 E mail sales acelshop co uk Trouble shooting Problem Load does not turn on Possible cause 1 Incorrect wiring 2 The ambient light level is too high Proposed solution 1 Refer to wiring diagrams See Fig 4 Fig 6 and check if the load is malfunctioned 2 Check the set Lux value and adjust it if necessary to a higher lux value Problem Load does not turn off Possible cause 1
Download Pdf Manuals
Related Search
Related Contents
GT10Q-SU/HU User`s Manual USA/Canada ROLE DU CHS SEMIS ET GERMINATION Konig Surgical Instruments Recommended Cleaning and manual para realizar la inscripción vía web a los programas de Slant/Fin Lynx LX-85A User's Manual Guide d`utilisation audio de LTspice PHOBOS BT A25 PHOBOS BT A40 - BFT Guía de referencia rápida Copyright © All rights reserved.