USER MANUAL

image

Contents

1.
2. USER MANUAL for Line Interactive 1000 1400 2000VA UPS Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models Line Interactive 1000 1400 2000 that should be followed during installation and maintenance of the UPS and batteries Safety CAUTION This UPS utilizes voltages that may be hazardous Do not attempt to disassemble the unit The unit contains no user serviceable parts Only factory service personnel may perform repairs Internal battery voltage is 24Vdc Sealed lead acid 6 cells battery Connection to any other type of receptacle other than a two pole three wire grounding receptacle may result in s shock hazard as well as violate local electrical codes In the event of an emergency turn the power switch to the off position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related item
3. allation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA e The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible Wichtige Sicherheitshinweise Bitte lesen Sie diese Hinweis sorgfaltig durch m Vor jedem rcinigen ist das Ger t vom Stromnetz zu trennen Verwenden Sie Keine Fl ssig oder Aerosolreiniger Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung m Das Ger t ist vor Feuchtigkeit zu sch tzen m ffnen Sie niemals das Ger t Das Ger t darf aus Gr nden der elektrischen Sicherheit nur von authorisicrtem Servicepersonal ge ffnct Werdcn m Bei der Installation is darauf zu achten das der Gesamtableitstrom der USV und der and der USV angeschlossenen Verbraucher den Maximalwert von 3 5mA nicht berschreiten m VORSICHT Explosionsgetahr bei unsachgem en Austausch der Batterie Ersatz nur durch denselben order einem vom Hersteller empfoblenem hnlichen Typ Entsorgung gebrauchter Batterien nach Angaben des Herstellers System Description Front Panel 1 Fault LED Y 2 AC Mode Load Level LEDs Backup Mode Battery OF Capacity LEDs 3 AC Mode Green Lighting Backup Mode Green Flashing 4 Power ON OFF Switch Back Panel Communication Port gt Circuit Breaker Cooling Fan Modem Phone Line Surge Protection AC Input Ins
4. d plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as shown Incoming Internet line 6 Serial Cable Connection To allow for unattended system shutdown for your operating system connect the serial cable as per diagram below 7 Turn On Off To turn on the UPS unit press the power switch lightly To turn off the UPS unit press the power switch again 8 DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn on the UPS 9 Battery Removal Follow the Chart 1 to Chart 3 to replace the batteries Disconnecting all sources of supply before battery replacement Remove the front panel Chart 1 Remove the battery cover Chart 2 After removing battery cover gently extract the battery by disconnecting the two wires connecting to the Blazer Be sure to replace the same type of batteries and dispose of old batteries properly at an appropriate recycling facility Chart 3 Software Installation WinPower WinPower is a brand new UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multi computer systems while power failure With this software users can monitor and control any UPS on the same LAN no matter how fa
5. r from the UPS le Be rg Ver 18 Spie Logs WPS Tools Monier Preference Language Hain JEEE Ek Rosi lan o al 3000 4 y CACA Apo FIA MY vio le zi heb ce Wyld SLE TI Ad Sel kT Installation procedure 1 Goto the website http www ups software download com winpower htm 2 Choose the operation system you need and follow the instruction described on the website to download the software 3 When downloading all required files from the internet enter the serial No 5110 1 01220 0100 478DF2A to install the software When your computer restarts the WinPower software will appear as a green plug icon located in the system tray near the clock Trouble Shooting Symptom Possible Cause i 1 Missing battery 1 Charge battery up to 8 hours 2 Battery defect 2 Replace with the same type of battery 3 Power switch is not 3 Press power switch pressed again Overload of the UPS Verify that the load matches the UPS capability specified in the specs noncritical load low hours or more 3 Battery defect due to 13 Replace with the high temperature same type of battery operation environment or improper operation to battery installed well the software 2 Cable is not properly 2 Check the RS 232 connected cable is firmly connected to COM1 COM2 of the computer and confirm the setting again broken breaker cord properly If any abnormal situations occu
6. r that are not listed above please call service people immediately Specification MODEL Oooo oo 1400 200 CAPACITY VA W 1000VA 600W 1400VA 840W 2000VA 1080W 115VAC or 220 230 240VAC INPUT Voltage Range 85 140VAC 162 290VAC 115VAC or 220 230 240VAC Voltage Regulation Ber Battery Mode wa OUTPUT 50Hz or 60Hz Frequency Regulation aten Moda Output Waveform Modified Sinewave Batten Tvoe 12V7Ah 12V9Ah x 2pcs y tye x 2pcs or REW45 12 x 2pcs BATTERY Back up Time al2 76 23 minutes 25 minutes 26 minutes load with 15 monitor Recharge Time 8 Hours to 90 after complete discharge TRANSFER TIME 4 6ms Typical The 1st green LED lighting INDICATOR The 1st green LED flashing Backup Mode The 2nd to 5th green gradually lighting indicating battery a city AC Mode The 2nd to 5th green LEDs gradually lighting indicating load level Capa Backup Mode Sounding every 10 seconds AUDIBLE Battery Low Sounding every second ALARM Sounding every 0 5 seconds Continuous sounding PROTECTION Full Protection Overcharge and Overload Protection PHYSICAL a iss 368 3X140 2X180 4 WEIGHT Net Weight 13 8kgs 14 2kgs 16kgs 0 40 C 0 90 Relative Humidity non condensing ENVIRONMENT INTERFACE Windows family Sun Solaris IBM Aix Compag True64 UnixWare FreeBSD HP UX Linux and MAC O O D o 5 O m lt O 5 3 5 Z e D D E D lt Oo 0 3 I ep N GO N
7. s such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose of battery or batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hand Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on the top of batteries Disconnect charging source prior to connecting or disconnecting batteries terminal 2 3 4 5 e Servicing of batteries should be performed or supervised by qualified personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number of the sealed lead acid batteries e This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen e During the inst
8. tallation and Operation Installing the UPS is as easy as following the steps shown Be aware of the Power Switch must be kept in the ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure 1 Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping If any damage is discovered repack the unit and return it to the place of purchase 2 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from monitor at least 20cm to avoid interference 3 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours 8 hours 4 Computer Connection Connect one computer related device into each of the power receptacles supplied on the back of the UPS maximum of three devices 5 Modem Phoneline Connection Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable an