1. BORRINGIA    MAKE EVERY Day A LITTLE BIT EASIER    User   s Manual    Aqua Shower Trolley       ena   gt t  I E 074 r    y iii aAA  ae 5 AT e  ENV T       Pr   a R    TRPPETTE LE Ke    Vrirreveee            a Soa    a m  os  d      b    i            gt     d _  ihe RS                   8   A       Technical Data    Contents   l  Introduction  2  Area of Use  5  Taking Aqua into use  4  User Instructions  5  Maintenance  6  Trouble Shooting  7   8     Warranty    Rev 1  07 03 01    9   BORRINGIA   BORRINGIA  User S Manual MAKE ser Day A LITTLE BIT EASIER    1  Introduction   Aqua  electrically height adjustable shower trolley with elevating head section    125mm castors with foot operated central brake  Folding guardrails in both sides   Hand control for electrical functions   Integrated battery and wall charging station  Optional Equipment  Back up battery    The Aqua Shower Trolley provides for problem free showering both for the carer and weak  patients  who cannot sit  The trolley is comfortable thanks to the height adjustable headboard and  foldable guardrails  which are infinitely variable  This means that most patients obtain an optimal  body support  The optional extra long trolley means that there is always amble access for head and  foot care  even with very tall users     The electrical lifting function provides optimal working positions for the carer both during  showering and transfer to  amp  from the trolley  The trolley can be tilted electrically  This increase
2. ong version   Length  external  Short version   Length  internal  Short version   Width  internal   Total width  guardrails vertical  Total width  guardrails horizontal  Total width  1 guardrail horizontal  Height of guardrails   Length  head section   Castors   Height of mattress  trolley horizontal  Max height  Trendelenburg   Minimum clearance  Length width  undercarriage  Thickness of mattress   Length of drain tube   Weight   Power needs   Max user weight   Max weight on head section    Warranty is granted on   1  Frame  amp  Mattress  2 years    2430 mm  2140 mm  2190 mm  1900 mm  550 mm   780 mm  1000 mm  890 mm   240 mm   650 mm   125 mm  430 960 mm  1340   1410 mm  130 mm  1390 670 mm  30 mm   1000 mm  80kg   230V  50Hz   200kg   60kg    2  Other parts  castors  batteries  actuators etc    1 year    If the trolley is incorrectly used  the warranty is not valid     
3. s  comfort and safety  If needed a patient can quickly be put into either Trendelenburg or Anti   Trendelenburg position     2  Area of Use  For washing   showering of weak patients     3  Taking Aqua into use     Upon reception  Unpack the trolley and check it thoroughly for  transport damages  Put the plug into a wall socket and control that all  electrical functions work  In case of damages or malfunctioning  contact  your dealer prior to taking the trolley into use     4  User Instructions     The electrical functions of the  trolley are operated on the hand  control  see illustration     1  Trendelenburg    1     2  Anti Trendelenburg    2 5    3  Lowers the trolley    4  Raises the trolley        The trolley can be controlled both  by the carer and the patient     5  Maintenance     9   BORRINGIA   BORRINGIA  User S Manual MAKE ser Day A LITTLE BIT EASIER    Adjusting the head section    1  Lift the section manually to the desired height and let go  It locks  automatically into place   2  In order to lower the head section  release the handle situated  underneath the mattress at the headboard whilst lowering the head  section with the other hand     Caution  The head section should not be exposed to more than 60 kg   The castors are equipped with a foot operated central brake     Adjusting the guardrails   1  The guardrails can be adjusted when the release handle is pushed   down  using hand or foot    2  Move rail to the desired position and let go      r  3  Adjustmen
4. t is step less  etal  4  Cannot be adjusted in Tren    delenburg position             Head   amp  Footboards    Can be removed for additional length   The head   amp  footboards are fixated  with thumbscrews underneath the mattress  at both ends           Keep the trolley free of dirt  hair  soap etc     Moving parts should regularly be controlled  tightened and lubricated  with acid free Vaseline     Cleaning    Clean the trolley with a soap water solution and a brush sponge   Wipe the trolley thoroughly dry after washing    Cleaning agents     The trolley  Household detergents  excluding alcohol  amp  chloride  agents     Mattress  Only soap water    The trolley should never be cleaned in autoclaves or put into hospital  washing streets     A yearly Service inspection is recommended     Contact your dealer for a service contract     6  Trouble Shooting     7  Technical Data     8  Warranty     User   s Manual    Malfunction of electrical functions       BORRINGIA    MAKE EVERY Day A LITTLE BIT EASIER    1  Has the plug been inserted into the wall socket    2  Does the wall socket supply power  Try another socket   3  Has the battery been charged      4  Are all plugs driven all the way home in the control box   situated  under the undercarriage     5  Is there any visual deformation to the trolley     6  Are there any visual cracks in cables     For further assistance  contact your dealer     Measurements  amp  Weight     Length  external  Long version   Length  internal  L
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Philips AJ3977 User's Manual  Installation Manual  Scaricamento - Officeserv.it  User Manual [  ] - American Industrial Systems, Inc.  YSS100 Setting Software  Manual de Instrucciones Balanza de grúa  SBS TEBB5200PW  Handbook - (MDP) Project - University of Cambridge  Page 6  Owner`s Manual    Copyright © All rights reserved. 
   Failed to retrieve file