        User's manual and installation instruction Personal
         Contents
1.      Gas smoke    alarm  The Propane detector is best tested with a short squirt of gas from a cigarette  lighter directly into the external low mounted sensor housing    Motion detector test    The outside mounted motion detectors are best tested by walking in the detector zone until the alarm  sounds  This should normally be approximately 30 seconds     False alarms    NX 4 will normally react on the propellant gas in spray cans and many other chemicals  If the air  quality gets poor because of insufficient ventilation or cigarette smoke  the alarm can react  If you  desire to accept the poor air quality  reduce the sensitivity settings to the desired level    The    Gas    and    Gas Smoke    detectors are sensitive to alcohol and will normally react if alcohol is  handled near the NX 4  If you are breading on the NX 4 after consuming alcohol  it shall react     Smokers may experience alarms even if they are not smoking at the moment  This is because of the air  quality is generally poorer than normal and a small added pollution could be enough to trigger the  alarm  If so  a lower sensitivity setting or added ventilation may be required    NX 4 is very sensible to car exhaust so if NX 4 is ON while driving  you will experience alarms when  driving in tunnels  close behind other cars or in heavy traffic  However  this should not be a problem  because NX 4 is normally OFF while driving  It does not harm anything to have it ON  but if motion  detectors are installed  the ala
2.     NX 4 is normally used when you are sleeping  Flip the power switch to    ON    position and the red     Heating    lamp will light  After a heating period of 2 3 minutes  the green lamp will light and NX 4 is  ready  but the CO2 detector will have a heating time of 30 minutes before it works    The sensitivity of the three gas detectors must be adjusted before the NX 4 is ready for use  When this  is done  the sensitivity is adjusted only when needed or if you are entering a new climate zone or  season of the year     Sensitivity adjustment     Let the NX 4 be powered for an hour or more   Turn the sensitivity knob for the    Gas    sensor up to the point the alarm triggers   Then turn the knob down two scale marks  or more  from the point the alarm trigged   Repeat this procedure for all three sensibility adjustments   Readjust the sensitivity when entering a new climate zone or season of the year  or if needed  otherwise   e When first installed or out of use for a long time  readjust the sensitivity after a day or two     Many people in a small space will normally require less sensitivity because of generally poorer air  quality  Too high sensitivity setting will increase the risk of unwanted alarm  Very low sensitivity  setting  turned all the way down  will not totally disable the alarm  but a higher density of gas is  required to trigger the alarm  In general there is no need to set a very high sensitivity  NX 4 will react  very well to gas anyway  Do your own exper
3.    5       p  gt    D aH    Fuse sikring  FU2  0 5A    The table below shows all the connections and their functions   Se the chapter    Technical  specifications    for electrical data                                             Terminal block J1 Propane CO2 sensor input   Terminal block J3 Motion detector  positive signal  1  5V DC out 1  12V ut  2   GND 2 GND  3 Signal input 3 Signal input  active positive  Terminal block J2 External outputs Terminal block J4 Motion detector  negative signal  1 All gas detectors combined 1  5V out  2 Propane gas separate 2 GND  3 Motion delayed 3 Signal input  active low  4 Extra alarm sounder Terminal block J6 Power supply in and lamp output  1 12   24V input  Power supply   2 GND  3 12 24 V out to lamps                   NB  The external signal outputs are unfused and will be destroyed if overloaded     Users manual NX 4b Page 7    Basic wiring     The illustration shows the power supply and propane CO2 detector connected to the unit    The power line is shown with a 15 Amp fuse  but smaller fuse can be sufficient if not outside mounted  lamps are used and connected directly to NX 4 without relay  More about this in the chapter     Installation                nd   II Fuse sikring    15A  Propane CO2 detector       NX 4 main unit 12 24V    Different types of wire can occur  When there is referred to color    Red brown    it means one of the  colors  not both     Wiring external motion detectors    Connect motion  detectors type NX M2  to 
4.    All the built in  functions in the NX 4 will provide an added insurance against these hazards  You might look at NX 4  as your    electronic night watch         Motion detectors are optional     Users manual NX 4b Page 2    What functions does NX 4 have   1  Warning of    narcosis    gases     Alarms many toxic gases with anesthetic or suffocative effect on humans  The four sensors will  together cover a very wide range of known and unknown gases  Two of the sensors are located in the  main unit to detect light gases and two are located low in the external unit to detect heavy gases like  propane  CO2 and other    narcosis    gases    Many of these gases will  in best case  in medium concentrations  make you sleep very heavy  If you  wake up you may act unconcerned to robbery  In stronger concentrations gas is life threatening    NX 4 will sound the alarm long before these gases reaches dangerous concentrations  If outside lamps  are connected to NX 4  they will flash when the    Gas    alarm is trigged  This will help to attract  attention from people near by     2  Warning of propane butane gas     This sensor is located in the external sensor unit and is installed by the floor in order to detect the  heavy propane gas as early as possible  This sensor is also very sensitive for hydrogen from over  charged batteries     3  Warning of fire     The    Gas smoke    sensor detects smoke by sensing the CO gas generated from the fire  It also detects  many other pollutions  ex
5.   If the best location is too far from the bed to hear the alarm  install an extra alarm  sounder by the bedside    A logical place to install NX 4 is beside the electrical distribution center often located above the door  in motor homes or at the wardrobe locker in caravans  At these locations you often get easy access to  electricity  To make the installation easy it is highly recommended to install NX 4 on a panel or locker  that has access for the wiring from behind  Also keep in mind tat the external Propane CO2 sensor also  shall be installed near by  In general the location of NX 4 is not critical in order to detect gas     Attachment    Remove the four screws retaining the front of the NX 4  enclosure  Attach NX 4 to the wall with two screws  trough the holes shown  Drill holes for the wires trough  the wall in the slots in the enclosure   If the wires shall  not go trough the wall  drill holes in the side of the NX 4  enclosure   When all wires are connected  reinstall the    front  Be careful not to bend the red indicator lamps in    _    the process  attachment holes               Install the external Propane CO2 sensor approximately 10 20 cm above the floor  The location is not  critical  Attach it by removing the protective film on the double sided tape or put a screw through the  lower part of the enclosure  Route the wire to the NX 4 unit  preferably behind a panel  inside a locker  or inside the door gasket      Power supply    If external outside lamps are no
6.  detectors are used  they have to be cleaned on regular basis  Clean with a cloth and  mild soap water  Avoid flushing directly at the detectors     Users manual NX 4b Page 10    Technical specifications NX 4                    Operating voltage  11 30V DC   Power requirements  2W   approx  140mA at 12V and 70mA at 24V   Relay output for external lamps J6 pin3   Max 10A load   Operating temperature  10 30   C   External alarm outputs  All alarm outputs are active as long as NX 4 is alarming         gt     Combined output for all J2 pin 1   Active low  Max load approx  0 4A each  47k pull up          gas detectors resistor  Low level  lt  1V   Separate output for the J2 pin2   Active low  Max load approx  0 4A each  47k    pull up     propane detector resistor  Low level  lt  1V         gt     Output for delayed motion   J2 pin3   Active low  Max load approx  0 4A each  47k    pull up     resistor  Low level  lt  1V        Output for extra alarm J2 pin4   12V approx  10 15mA max load  Volume adjustable   sounder Active low analog output        Motion detector inputs       12V output in 12V systems   J3 pin    10 12V  max approx  200mA load       12V output in 24V systems   J3 pin    12V  max approx  50mA load                            SV output in J4 pin 1   5V  max approx  50mA load  Current limited by a 10  12 24Vsystems ohm resistor in series   Signal input positive J3 pin3   3 5 30V positive signal  Approx  20k input  imp   Signal input negative  J4 pin3   Active below 1 
7. 5V  Approx  20k input  imp   Delay time at stage 2 for the motion Approx  6 30 sec  provided the signal is constant from  detector alarm detectors  Adjustable with internal potentiometer   Dimensions  L  W  H  143x82x38mm  Weight  210g               With Propane CO2 detector connected  but without any other external equipment   NX M2 motion  detectors power consumption can be neglected      To visualize the power consumption of NX 4  a 12V 70 Ah battery will be emptied in 7 weeks if used  only at night     Connection terminals overview                                                    Connector J1 Propane sensor Connector J3 Motion detectors with positive signal  1 Red brown  5V 1  12V out  2 Green GND Ground 2 GND   Ground  3 White Signal 3 Signal input  active high positive  Connector J2 External outputs Connector J4 Motion detectors with negative signal  1 All gas detectors combined 1  5V out  2 Propane gas separately 2 GND  Ground  3 Motion  delayed 3 Signal input  active low negative  4 External alarm sounder Connector J6 Power input and lamp output   1 12   24V Power supply   2 GND   Ground   3 12 24 V output to external lamps                   Users manual NX 4b Page 11    CE Approval   NX 4 meets the following standards     Immunity  EN 50082 2  Emission  EN 50081 1    Safety    NX 4 is made as a safety aid device  It can   t guaranty safety  If NX 4 shall be used in environments  where NX 4 shall provide vital safety alone  special requirements apply  Consult the ma
8. Nor      Tronix    User   s manual  and installation instruction    NX  4b    x NX 4   Motion     Vol  Personal Safety System  os Gas  smoke and motion    Oia  Delayed Instant detection alarm     Gas      O Alarm ready       Heating    Propane CO2 3   Sens  ON    Nor Tronix Norway    vl      Sens   rN  vi    Gas Smoke   Sens   oN   i OFF   via   t     CE       Personal Safety System for  mobile homes  Alarm for gas  smoke and motion      Motion detectors optional     Rev  13b  Page 1    Users manual NX 4b    Introduction    Thank you for purchasing a NX 4 security system  Since your and others safety may relay on proper  function of this product  we ask you to carefully read this manual so you can fully understand how to  use it  how it works and how to install it  It is not very complicated     Table of contents     Whatis NX  intended forn nemenin a ated lees oe E E E Pause wasnt 2   1  Warning Of narCOSiS    BASES racapein ape reaa E A EAER AEE ETERA EARE 3   2  Warning Of PropAane Dutan    Qas  pene eciiieri iia aAa A AEE aAA aS EAA EAEri AE ri aaa 3   Bs Warmingof fire necndoni s e a a e a A AA 3   4o Warning Of perons nearDy ieser ia A T AA AA a EN E AE Aaa 3  What eases do  s th   NX A d  tect  assitir te e eie e a a eii 3  How to use the NXA nncs iacent e a EER A EE E REEE EES 4  How to test the NX  Arrien a N E T E dy E E TEE 5  False alarms soseri E A E a Janeen es asa went 5  Tnstall  tioNesns ine a a ATE E E ETEA E AAE O ERNE 6  Connec ton arnee r gaea e kame a r 
9. er    Adjusting the sensitivity for the Motion Detectors         Users manual NX 4b Page 4    How to test the NX 4    Test shall be performer regularly and always after a long period of storage    Turn up the sensitivity adjustment knobs just until the alarm sounds and back again  At this time also  note how much you have to turn up the sensitivity up to trigger the alarm  This shall normally be 2 3  scale marks  Repeat this procedure for all three sensitivity adjustment knobs  The CO2 detector   located in the external low mounted sensor housing  is tested by blowing directly at the sensor with a  few deep breaths  You can use a flexible straw or tube to make it easier for the breath to hit the sensor   The CO2 content in your breath is just enough to trigger the alarm  Remember that the CO2 detector  has 30 minutes warm up time before it can be tested  The CO2 detector has automatic sensitivity  adjustment and will not be tested or affected by the    Propane CO2    sensitivity adjustment knob   Propane and CO2 alarm is indicated with the same lamp on NX 4  but you can distinguish the two by  different sound and flash pattern  CO2 gives an uneven pulsating tone and a flashing lamp  all other  gases gives even pulsating tone and constant light  in the indicator lamp on NX 4     A more reliable test is to apply real gas  When NX 4 has been powered for a while  hold an open  bottle of alcohol in front of NX 4 and blow over the bottle against NX 4  This should give    Gas    and
10. haust and bad air quality in general  This detector may alarm even if no  smoke is evident  This is in most cases because of poor ventilation     4  Warning of persons nearby     NX 4 can be equipped with outside mounted motion detectors  option  to detect persons close to the  vehicle  Occasional by passers will not create an alarm  but if motion persists in the alarm zone for  certain amount of time  the indoor alarm will sound  One detector on each side will alarm if a person  walks around the vehicle  but not if someone just passes by     Connection of external equipment     NX 4 has several external alarm outputs for connection of equipment like additional alarm sounder   forwarding of alarm signals to a cellular phone alarm sender  external flood lights  propane gas shut  off valve and so on     What gases does the NX 4 detect     NX 4 has four different gas detectors  Each detector has a specific target gas  but they all will also  overlap each other to a certain extent  Together they will detect most gases that are toxic  anesthetic   explosive or suffocative  Two of the sensors are located in the external low mounted Propane CO2  sensor housing                             NX 4 Main unit Eksterne Propan CO2 sensor  Gas sensor  Gas smoke sensor  Propane sensor  CO2 sensor   Toluene Hydrogen Propane butane CO2  Ethanol Ethanol Hydrogen  Hydrogen sulfide Propane butane Ethanol  Amonia CO  Hydrogen Methane                   Users manual NX 4b Page 3    How to use the NX 4
11. ia e ea en a ea date et S 7  Basie WHN ig a paisa eaa a a neta a a a a gan So a a E a 8  Wiring external motion detectors 4 3  doxcatscacciuds dpacseataus tesuosdatagouzeced sees cueeceta ean Bebe 8  Adjusting the sensitivity for the motion detectors 2 0    eee eeeseeceeneeceseeeceeneeceeeeecssneeeeneeeeeaeeeenae 9  Connection of external outside Lights o  scsccccciveccecdacassiausageacaasncecasa se deacdaawnsatennedeadeanvenaseebedeeedenes 9  Connecting external lamps with extra relay  ccciiiscc Seccdecasscesdkcesonsecdenweddacosecsdndsecessacstocsetanscensss 9  Connecting extraalarmi soundet  nan ee Saisie vases i onda Bante a ins 10  Connection of extra outputs with relay          eee ceesscecssncecssececeeccecssecececeecseeeecseeeeeseeeeseeeenaeeees 10  IAIN ATIC Cvs cae hidinen ies ostesd ea a heat cans coed fuse ae cee seta al cea E wi Meas cat te oe 10  Technical specifications NXA eenia nae Ea eae a ens eas 11  COnMECHOM pO CV V W ooo os ccc e aaea kas E aoa acouses a EEEa N E aes 11  CE Approval isrener e a ea a e e o na nay aE oisg 12  Safety enn E n O E E a a a a a anG 12  Ma a n E 12  LVS acs sa hace a A a pestene an ea gas Uma cheeses aoe a sane goes 12    What is NX 4 intended for     NX 4 is a personal safety alarm system primarily intended for use in mobile homes where health and  life can be endangered if you are attacked with narcosis gas by robbers  gas leakage from your own  gas apparatus  fire or unknown persons  which may be robbers  close to the vehicle
12. iments to see how sensitive you want the alarm to be   The CO2 detector has fixed sensitivity and is not affected by the    Propane CO2    sensitivity knob  The  COz sensor is connected to the Propane sensor input so high CO2 concentrations will flash the     Propane CO2    lamp and alarm with an uneven pulsating tone  Any other gas will give constant light  in even pulsating tone and light the respective lamp  This way there will always be possible to  determine witch sensor that triggered the alarm     If outside mounted motion detectors are connected     The motion detectors have two stages  The first stage is triggered immediately when motion is  detected  No alarm will sound  but the    Instant    lamp and outside light will light  if outside lamp is  connected   The next stage is delayed and gives an audible inside alarm if motion persists in the  detection zone  If you are at a    safe place    where people normally pas by  you don   t want an audible  alarm when outside motion is detected  Turn down the volume knob for    Motion     all the way or  something in between if you want a discreet alarm if motion is detected outside    If outside lamp is connected it is useful to leave the NX 4 powered in order to make a welcome light  for your selves when coming home in the dark  Automatic outside lamps also have a frightening effect  on burglars    The delay  or sensitivity  is adjustable with the Motion detector sensitivity adjustment knob inside the  NX 4  see the chapt
13. nder can be  desired if the NX 4 is located  far away from the bed or if you  have a hearing damage  Almost  any 12V type of sounder  consuming no more than 10   15mA will work  also use 12V  types in 24V circuits     When you are adjusting the  volume at the outside detector  alarm  the volume at the extra  sounder also is adjusted     Buzer lydgiver       Connection of external outputs with relay    The external outputs are signal outputs with limited current capacity  Extra relay must in most cases be  used  This example shows how to connect a powerful siren  The same circuit can be used for all  outputs at terminal block J2  The outputs can be combined by directly connecting them together at J2   Se the chapter    Technical specifications    for more information about the electrical characteristics in    Alarm horn       Fuse sikring  15A    Maintenance    No particularly maintenance is required  but regularly readjusting of the gas detector sensitivity is  recommended  This will ensure proper function and avoid false alarms   Regularly do a full function test as described in the chapter    How to test NX 4        If NX 4 is used constantly  we recommend sending the unit for service and possible sensor  replacement after approximately 6 years     If NX 4 has been exposed to high air humidity or left OFF for a longer period of time  it may be  required to leave it ON for a day or two before you readjust the sensitivity and doing a quick function  test     If outside motion
14. nufacturer for  information     Warranty    1 year from the date of purchase  The warranty cover faults related to manufacturing  The warranty  does not cover damages by incorrect connection  use or normal wear     Service   If your NX 4 needs service  consult your dealer     Remember to provide an exact fault description     Manufacturer   Nor Tronix    Norway  www nor tronix no    Your dealer   Nor        Tronix    Users manual NX 4b Page 12    
15. oid false alarms from animals  sunlight  warm winds   occasional by passers and so on     Connection of external outside lights    You can connect this output to an already  existing outside lamp with a wire directly from  NX 4 to the lamp without any fuse or switch  in between  The lamp will automatically be  turned on by NX 4  when powered  or  manually with the existing light switch  NX 4  is not damaged if you supply current in to the  lamp output  You can also connect this output  to the hazard lights or parking lights if desired   Maximum load is approximately 100W  if  extra relay is not used   Suitable lamps can be  outdoor lamps for motor homes or caravans   working lights for tractors  extra lights for  cars  backing lamps and so on    See more about wire gauge and fuse size  requirements in the chapter    Installation   power supply             Jord  Gnd     II Fuse sikring  15A         12 24V    Connecting external lamps with extra relay    If you want to connect  more lamps requiring  more current than NX 4  can deliver directly   approx 100W   an  extra relay can be used   With an extra relay you  also take load away  from NX 4 so you can  supply NX 4 from a  low capacity circuit   This can in many cases  simplify the installation  if NX 4 is already  connected to a circuit Fuse sikring  without the capacity to 15A  supply the lamps                   Jord  Gnd     Fuse sikring    Users manual NX 4b Page 9    Connecting additional alarm sounder    Extra alarm sou
16. rm will sound constantly  and outside lamps light  if installed       The motion detectors reacts on everything hotter than the background  as long as it moves  That  includes animals  sunlight behind a branch moving in the wind  warm gusts and humans  This will  cause the light to come on  if equipped   but no alarm will sound at this point  If the motion in the  detection zone persists for a while  the alarm will sound  This delay will in most cases eliminate false  alarms  but if false alarms still occur  you can reduce the sensitivity  More detectors create more  false   detections and often requires lower sensitivity setting   False detections lights the outside light  but  that is not considered a problem   Also see the chapter    Adjusting the sensitivity for the motion  detectors         Users manual NX 4b Page 5    Installation    Location    Install the NX 4 main unit approximately in the height of your head in a free and open place in the  living area where it is easy to reach  Do not install it inside a locker  NX 4 will react on alcohol  so  avoid placing NX 4 close to a cellaret if possible  NX 4 will react on    spent air    human breath with  alcohol  perfume and human    wind    so if the ventilation is poor  this may create    false     alarms   Therefore install NX 4 at an open location where such gases are thinned out before they reach NX 4   It is not recommended to install NX 4 too close to a bed and absolutely not in a small closed sleeping  compartment
17. t used  NX 4 can be powered from any circuit without any noticeable  power capacity because NX 4 consumes very little power  2W   If outside lamps are connected  directly to NX 4 the power must be taken from a circuit with larger capacity than the already existing  load and the extra lamps together  Alternatively install a relay for the lamps in order to reduce the  power requirement to the NX 4 unit   An alternative to heavy gauge wires to NX 4     If Outside lamps are connected  the fuse inside NX 4  for external lamps  must be smaller than the  fuse on the circuit it is powered from  This way the NX 4 will keep on working as a gas alarm even if  the outside lamps are short circuited and the fuse blows  Change the existing 10A fuse with a smaller  one if the power of the lamps are considerable less than this    In motor homes  preferably power NX 4 from a circuit that is turned off when the main switch is off     Two Propane sensors    Some motor homes has double deck floor  If desired  NX 4 can be equipped with two propane sensors  connected in parallel  One in the living area and one below the floor     Users manual NX 4b Page 6    Connection   All wire terminal blocks are referred to as J1  J2  J3 and so on  Each       J block    has numbered pins  The  illustration below shows the NX 4 internals when the front is removed  Also note the location of the  internal fuses     Fuse sikring    Motion bevegelse  J1 9 FU1  10A    Sensitivity f  lsomhet          H  r   LEP  ey   
18. terminal block J3   Many detectors can be  connected in parallel    Terminal block J4 is  for detectors with active  high positive signal  Se  the chapter     Technical  specifications    for more  information     I you want to totally  disable the motion  detector function  not  only the alarm sound  that you can turn off on  the NX 4 main unit   Yellow  you can install an Green Blue  external switch on the   power cable to the   motion detectors  J4 pin   1     Different types of wire can occur  When there is referred to color    Red brown    it means one of the  colors  not both     Bevegelse folsomhet   Motion sensitivity       Users manual NX 4b Page 8    Adjusting the sensitivity for the motion detectors    The sensitivity for the motion detectors can be adjusted to your needs  Normally  the mid position of  the adjustment wheel is a good starting point if you have one or two detectors   The adjustment wheel  is yellow and located inside the NX 4 unit   If more than two detectors are used  lower sensitivity may  be desired  If you are experiencing false alarms  turn down the sensitivity  More info in chapter    False  alarms      Maximum sensitivity is when the knob is turned fully clockwise  and the opposite  Do your  own test of the sensitivity by walking into the detection area and see how long it takes before the  alarm reacts  A good starting pint is about 30 seconds   If you are standing still you are invisible to the  detectors   Do not set it too sensitive to av
    