Baxi EcoBlue System Owner's Manual
Contents
1. 7 3 Re pressurising the System ic l am bar Normal Pressure Requires Repressurising Tap In Open AHS Positi In Open Position Pipe Fitted For Repressurising Remove after use EcoBlue System 1 If the water pressure is too low the installation must be re pressurised 2 The normal operating water pressure is between 1 and 2 bar If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated E117 displayed Ensure that the filling loop is disconnected Contact your installer 3 It may be necessary to repressurise the system occasionally when the water pressure falls below 0 7 or E118 displayed A filling device the filling loop will be fitted on the system Normally this will be situated on pipework close to the boiler RS If the water pressure requires regular re pressurising a fault or leak is indicated Seek advice from your installer 4 If you are unsure of its position or cannot identify it consult the installer who fitted the boiler 5 The filling loop consists of two isolating taps and a separate filling pipe with connection fittings 6 Only when repressurising should the filling pipe be connected between the two taps Ensure that the nuts on the pipe ends are tightened onto the taps 7 Fully open one of the taps first and then while watching the pressure gauge carefully open the second t
2. EcoBlue System Safety 2 DANGER If you smell gas Turn off the gas supply at the meter Open windows and doors in the hazardous area Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Warn any other occupants and vacate the premises Telephone the National Gas Emergency Service on 0800 111 999 GP IS If a water or gas leak occurs is suspected the boiler can be isolated at the inlet valves by turning their taps through 90 1 4 turn downwards For advice please contact your Installer Annual Service Provider or heateam The Service Division of Baxi You can contact heateam on telephone number 0844 871 1525 When contacting heateam it will be useful to have the benchmark checklist at the back of the Installation amp Service Manual to hand as it includes details relevant to the boiler and installation AN WARNING Do not touch flue chimney pipes Depending on the settings of the appliance the temperature of flue chimney pipes may exceed 60 C Do not touch radiators for long periods Depending on the settings of the appliance the temperature of radiators may reach 85 C Take precautions with domestic hot water Depending on the settings of the appliance domestic hot water temperature may reach 65 C CAUTION
3. gt System Pressure between 0 5 and 2 5 bar Sule gt 5 external timer Turn Room Thermostat to maximum setting typical example shown 15 20 Ensure timer is set for Central Heating ON see any instructions supplied with timer EcoBlue System If the reading falls below 0 7 bar repressurise the system as described in section 7 4 Error Code 118 showing low pressure 7212141 02 06 14 Is the E and R symbol illuminated or flashing YES Operation OR gt Is the Spanner symbol illuminated or flashing YES To display the water pressure press P until is shown i will alternate with the system pressure NOTE When the pump is running the gauge under the boiler may show a slightly different reading to the display 7212141 02 06 14 Flame _ RES Failure A q I Spanner 1 7 a 1 4 4 symbol hk 44 Press the Reset Button CONTACT If it does YOUR INSTALLER SERVICE ENGINEER Reset Button If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible EcoBlue System 17 outdoor sensor relay kit 18 THES
4. United Kingdom en User Guide Gas Fired Wall Mounted Condensing System Boiler EcoBlue System 12 15 18 24 28 32 Please keep these instructions in a safe place If you move house please hand them over to the next occupier Model Range Baxi EcoBlue 12 System G C N 47 077 95 Baxi EcoBlue 15 System G C N 47 077 96 Baxi EcoBlue 18 System G C N 47 077 97 Baxi EcoBlue 24 System G C N 47 077 98 Baxi EcoBlue 28 System G C N 47 077 99 Baxi EcoBlue 32 System G C N 47 470 01 Dear Customer Thank you for purchasing this appliance Most illustrations in this document show the 12 15 18 24 28 models Where the detail for 32 model differs it is described in the text or shown ina specific diagram Please read this manual carefully before using the product and keep it in a safe place for future reference In order to ensure continued safe and efficient operation we recommend that the product is regularly maintained Our Service and After Sales organization can assist with this We hope you will receive many years of satisfactory service 2 EcoBlue System THE MARK OF QUALITY FOR THE INSTALLATION COMMISSIONING AND SERVICING OF DOMESTIC HEATING AND HOT WATER SYSTEMS Baxi Heating UK Ltd 2014 All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means or stored in any retrieval system of any nature inc
5. see the Table of Error Codes 2 When the spanner is displayed the error cannot be reset by the user Please contact your Installer Annual Service Provider or heateam The Service Division of Baxi to arrange your Annual Service You can contact heateam on 0844 871 1525 When contacting heateam it will be useful to have the benchmark checklist at the back of the Installation amp Service Manual to hand as it includes details relevant to the boiler and installation 3 fault errors be reset by pressing the d R button and holding for two seconds L Error Codes 117 and 118 can be reset by restoring the correct system pressure as described in 7 4 AN WARNING If an error code different from those described in the Table of Error Codes appears on the display or a certain fault appears frequently contact heateam EcoBlue System 23 Troubleshooting 8 2 Fault Finding Problem There is no domestic hot water The radiators are cold The boiler is not working 24 EcoBlue System 1 If the boiler is not working also check section 5 3 Operation Checking Procedure amp Basic Fault Identification or contact your Installer Possible Causes The boiler is not working The water pressure is too low lt 0 5 bar Insufficient flow The temperature set point for the heating is too low The heating mode is deactivated The radiator valves are not open The boiler is
6. 5 2 Frost Protection 5 3 Operation Checking Procedure amp Basic Fault Identification 4 1 9 9 5 9 2 53668655 16 Settings Sack fuss Stee ab che toes 18 6 1 Siting the Boiler Temperature ssescssescccssstssssessscessssissesdiects ninn O RRE RR ERNE 18 6 1 1 Boiler Flow Temperature sie ciscsasssenvae cssescsaccecsgnecesassssicuassatscsagseenvaiscsieasecatetaguacchiaisthdsazsacsceagteniadeqsseiseaateieasics 18 6 1 2 Inactive BUTLOMS erent e i a ana R 6 1 3 On Off Selector Button 6 1 4 Display eeeese eee eeseeenteeessnnseesnnsteesnnssseecnnsseecsnnseessnnssceesnnseeessnsseessnnsacessnnsesennnaeessnnassesennseesonness isk ee eee dec ee 7 1 General 7 2 Maintenance Instructions 7 3 Repressurising the System 7 4 VENTING the 5 7 5 Draining th System ai 7212141 02 06 14 EcoBlue System 10 11 12 Contents Troubleshooting E ENEO E E EE EEE E EE 23 8 1 Error Codes teroseeessssseossusenuseueosonsesscseososososeseosonsseseseososeseosseasossacesssasoessesoseasoseecssaseeoseeseoseseoeseososcseosssososcueososososeuessesoeoseseesoseeessesesseeeene 23 8 2 Fault Finding bassssesssssneeseneaeossnessossacsssrsesesueasoscucssosoacoensosossneososs
7. Do not neglect to service the appliance Contact a qualified professional or take out a maintenance contract for the annual servicing of the appliance 7212141 02 06 14 2 Safety 2 2 Recommendations 7212141 02 06 14 AN CAUTION Only qualified professionals are authorised to work on the appliance and the installation The appliance has an integral frost protection mode as long as there is power to the boiler Regularly check the water pressure in the system recommended pressure is 1 5 bar RS See section 7 4 Keep the appliance accessible at all times Do not remove or cover the user information and serial number labels affixed to the boiler control flap They must remain legible throughout the lifetime of the appliance 2 2 1 Benchmark Commissioning Checklist 1 Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations England and Wales 2 All installations must be notified by the installer to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued to the customer who shoul
8. or cold water pointlessly Fit a water saving shower head to save up to 40 energy Take showers rather than baths A bath consumes twice as much water and energy 7212141 02 06 14 12 Warranty 12 1 General 12 2 Terms of Warranty 7212141 02 06 14 Warranty 12 Baxi would like to thank you for buying one of our appliances and for your trust in our product In order to ensure continued safe and efficient operation it is essential that the product is regularly inspected and maintained Your installer annual service provider or our service division heateam can assist with this 12 2 1 Standard Warranty Terms and Conditions Warranty Registration Service amp Repair For the warranty to be activated and maintained please make sure Benchmark Checklist is completed by your installer Warranty is registered with Baxi The boiler has an annual service Please be aware that if you do not activate your warranty a basic one year warranty will apply For full terms and conditions visit www baxi co uk terms Benchmark Checklist This checklist will be completed by your installer and records whether the boiler has been installed correctly This checklist can be found at the back of the Installation and Service Manual and should be retained over the life of the boiler Ways to Register Your Warranty If your boiler is eligible for a promotional warranty your installer will register the product on your behalf
9. A 150mm Min y 450mm Min lt gt For Servicing Purposes amp Operating the This is MINIMUM recommended dimension Greater clearance will aid installation and maintenance Controls 5mm Min In Operation gt Technical Specifications 295mm 7212141 02 06 14 3 Technical Specifications 3 1 Technical Data 32 Central Heating Primary Circuit Pressures Safety Discharge Max Operating Min Operating bar 2 5 0 5 Recommended Operating Range 1 2 Temperatures Boiler Flow Temp adjustable 25 C to 80 C max 5 C Electrical Supply 230V 50Hz Appliance must be connected to an earthed supply Electrical Protection IPX5D without integral timer IPX20 with integral timer External Fuse Rating 3A NOTE All data in this section are nominal values and subject to normal production tolerances Dimensions amp Clearances These must be maintained in the event of any alteration in the property e g additional cupboards etc 5mm Min gt lt 450mm 5mm Min gt _ 175mm Min 300mm Min if using 80 125mm flueing system ae 7212141 02 06 14 A 763mm 150 yY This is MINIMUM recommended dimension Greater clearance will aid installation and maintenance 450mm Min For Servicing Purposes amp Operating the Cont
10. E BUTTONS Settings 6 Settings 6 1 Setting the Boiler Temperature BABA Display Screen Boiler Flow INACTIVE Temperature except when an Adjustment is connected On Off saar Button C Ty Boiler Flow Temperature Displayed The values displayed are the temperature as measured at the boiler not necessarily that at the radiator or tap Because of differences in systems seasonal variations in mains water temperature etc some adjustment of the temperatures may be required to achieve the desired results Your installer will be able to offer advice Where Outdoor Sensor fitted If the control system includes an Outdoor Sensor the temperature display and Central Heating buttons perform different functions than those described Display This shows a simulated room temperature set point NOT the boiler temperature III Buttons They will alter the displayed temperature and for optimum use should be used to change the displayed temperature to the same as selected on the room thermostat By selecting a temperature different to the room thermostat altered comfort levels may be achieved Buttons When DHW mode these buttons active The boiler flow temperature set point will be shown on the display this must be AT LEAST the same temperature as the cylinder thermostat and can be changed using these butto
11. Re pressurising amp Venting the system If in doubt seek advice from your installer After draining and re pressurising the concentration of system corrosion inhibitor and anti freeze may become excessively diluted seek advice from your installer 7212141 02 06 14 8 Troubleshooting 8 1 Error Codes m Display typically after reset Burner Flame Indicates burner is on Table Of Error Codes Examples of Error Codes Z Z ml al a When this symbol flashes a Domestic Hot Water or Central Heating demand is indicated 420 Central Heating NTC Fault H28 Flue NTC Fault H10 Central Heating Return NTC Fault 1108 Safety Thermostat Operated pump fault 4111 Safety Thermostat Operated over temperature my 117 Primary System Water Pressure Too High m 118 Primary System Water Pressure Too Low 1259 Circulation Fault Primary 128 Flame Failure no lock out 13024 Flue NTC Operated 133 Interruption Of Gas Supply or Flame Failure 9 15119 Flame Failure 1608 Fan or Fan Wiring Fault 384 False Flame 7212141 02 06 14 Troubleshooting 1 In the unlikely event of an error occurring the display will show one of two symbols or In both cases the display will also show symbol and the numeric value of the error
12. a value 3 Press 1 to return to the normal display 7212141 02 06 14 7 7 1 7 2 Maintenance General Maintenance Instructions 7212141 02 06 14 Maintenance 7 1 The boiler does not require any special maintenance However the boiler must be serviced annually in accordance with the Installation and Service Manual and the relevant section of the Benchmark Service Record completed in order to maintain the warranty L Taking out a maintenance contract is recommended AN CAUTION Maintenance operations must be performed by a qualified competent person Use only genuine spare parts 2 The painted panels should be wiped with a damp cloth and then dried completely DO NOT USE ABRASIVE CLEANING AGENTS 1 The central heating installation should be checked regularly Proceed as follows e Check the water pressure the central heating installation If the water pressure is lower than 0 7 bar the water must be topped up If necessary top up the CH installation recommended water pressure between 1 and 2 bar e Check radiators for leaks and especially in damp areas for rust Open and close the radiator valves several times a year to ensure they can still be rotated e Only clean the outside of the boiler with a damp cloth Do not use abrasive cleaning agents AN CAUTION Only a qualified installer may clean the inside of the boiler EcoBlue System 19 20 Maintenance
13. acosonssesessososeseosossseseososeossueseoscaeosoasseossesssseseoesscseosossseessesepseseoesaseeoseeeaeos 24 Decommissioning E E cetsnceenscessssncesssascsseacdstaassesencesseacetisccestoacsessansstaeeseusivevesauesscdesstadeseesceseuasesreasesrenewess 25 9 1 Decommissioning Procedure bessesesssseseeesseasossnsssosesesesssscoeseasoseneososeseosonsseosssoesseseososessossssseosoesesseseoesseueossssseosseoessneecssanseoseseaeos 25 Disposal K KSENA KESSA KKPANNK ASau eSsE 10 1 Disposal Recycling Environmental EAE 11 1 Energy Saving Warranty aus yo lassi sk casas ES N D E L asadsesouatuentuseas ings EE 27 12 1 General 27 12 2 Terms of Warranty EEPE IT A PE EOE AT A 27 12 2 1 Standard Warranty Terms Conditions 27 EcoBlue System 7212141 02 06 14 1 Introduction 1 Introduction 1 1 General 1 2 Additional Documentation 1 3 Symbols Used 7212141 02 06 14 AN WARNING Installation repair and maintenance must only be carried out only by a competent pers
14. and will provide you with the relevant documentation In such cases there is no further action required on your part For a standard two year warranty please use one of the following methods Freephone 0800 013 7989 Register online at www baxi co uk registration Return the enclosed registration card EcoBlue System 27 12 28 Warranty Serial Number Label User Label EcoBlue System Boiler Control Flap Annual Service An annual service must be completed every 12 months from the date of installation This service must be completed by your Gas Safe registered installer e heateam the service division of Baxi telephone 0844 871 1525 or another Gas Safe registered engineer If you experience a problem with your boiler Please check that there is a gas electricity and water supply to the boiler Contact your installer because the fault may not be related to the boiler If your installer confirms that the fault is with the boiler simply call heateam on 0844 871 1525 heateam is open Monday to Friday 8am 6pm weekends and Bank Holidays 8 30am 2pm excluding Christmas Day and New Year s Day Before calling heateam please have the following information to hand Boiler serial number e g BMY073450028CP see opposite for location of serial number Your installer s name and address Proof of purchase if you do not have the boiler serial n
15. ap 8 The system pressure is shown at all times on the pressure gauge and can be viewed on the display when there is power to the boiler 9 To check the water pressure on the boiler display press 1 P until i is shown This will alternate with the system pressure When the pump is running the pressure gauge may show a slightly different reading to the display 10 When the figures on the display or needle on the pressure gauge indicate between 1 and 2 bar turn both taps off 11 Disconnect the filling pipe from the taps a small amount of water may be present and remove it Keep the pipe in a safe place for future use 12 If blanking caps are available fit them to the taps Go to the How to videos section of the Information amp advice page at www baxi co uk for further details 13 When the correct pressure is restored the boiler will reset automatically 7212141 02 06 14 7 4 Venting the System 7212141 02 06 14 Maintenance 1 If any air is present in the appliance or system it must be removed in order to prevent nuisance noises that may occur during heating or when drawing off hot water Proceed as follows 1 Open the valves of all the radiators connected to the system 2 Set the room thermostat to the highest possible temperature and any timers to ON 3 Wait until the radiators are warm 4 Switch off the boiler 5 Vent the radiator
16. d on receipt write the Notification Number on the Benchmark Checklist 3 This product should be serviced annually to optimise its safety efficiency and performance The service engineer should complete the relevant section of the Benchmark Service Record in the Installation amp Service manual after each service 4 The completed Benchmark Checklist amp proof of annual servicing where applicable will be required in the event of any warranty work EcoBlue System 10 3 Technical Specifications 3 1 Technical Data 12 15 18 24 28 Central Heating Primary Circuit Pressures bar Safety Discharge 3 Max Operating 2 5 Min Operating 0 5 Recommended Operating Range 1 2 Temperatures Boiler Flow Temp adjustable 25 C to 80 C max 5 C Electrical Supply 230V 50Hz Appliance must be connected to an earthed supply Electrical Protection IPX5D without integral timer IP20 with integral timer External Fuse Rating 3A NOTE All data in this section are nominal values and subject to normal production tolerances Dimensions amp Clearances These must be maintained in the event of any alteration in the property e g additional cupboards etc 5mm Min 390mm gt lt 5mm Min a ee 175mm Min 300mm Min if using 80 125mm flueing system y HL 700mm EcoBlue System
17. e DANGER Risk of a dangerous situation causing serious physical injury WARNING Risk of a dangerous situation causing slight physical injury CAUTION Risk of material damage Signals important information Signals a referral to other instructions or other pages in the instructions 4 gt EcoBlue System 1 4 Abbreviations Glossary 1 5 Extent of Liabilities EcoBlue System Introduction 1 DHW Domestic hot water CH Central heating GB Great Britain IE lreland BS British standard HHIC Heating and Hotwater Industry Council YY YV vV V 1 5 1 Manufacturer s Liability Our products are manufactured in compliance with the requirements of the various european applicable Directives They are therefore delivered with marking and all relevant documentation In the interest of customers we are continuously endeavouring to make improvements in product quality All the specifications stated in this document are therefore subject to change without notice The manufacturer will not accept any liability for loss damage or injury arising as a result of gt Failure to abide by the instructions on using the appliance gt Failure to regularly maintain the appliance or faulty or inadequate maintenance of the appliance P Failure to abide by the instructions on installing the appliance This company declares that no substances harmful to health are contained in the appliance or used durin
18. em 13 4 Description of the Product 44 Standard Delivery 1 The literature pack contains gt Literature pack Installation amp Servicing Manual e User Guide Instructions e Registration Card Envelope e Fernox Leaflet Wall Template 45 Accessories amp Options Exes 1 Various timers external controls etc are available as optional extras gt Outdoor Sensor Wired gt Mechanical Thermostat gt Mechanical Timer 24 hr Plug in gt Digital Timer 7 day Plug in gt Single Channel Timer Wired gt Two Channel Timer Wired gt RF Digital Programmable Room Unit Wireless gt RF Mechanical Programmable Room Unit Wireless gt Condensate Discharge Pump and Pipe Trace Heating gt Flue Accessories elbows extensions clamps etc refer to the Flue Installation Guide supplied in the literature pack gt Remote relief valve kit gt Boiler discharge pump gt 1M Condensate Drain Pipe Trace Heating Element gt 2M Condensate Drain Pipe Trace Heating Element gt 3M Condensate Drain Pipe Trace Heating Element gt 5M Condensate Drain Pipe Trace Heating Element Any of the above MUST be fitted ONLY by a qualified competent person Further details can be found in the relevant sales literature and at www baxi co uk 14 EcoBlue System 7212141 02 06 14 5 5 1 5 2 Operation Shutdown Frost Protection 7212141 02 06 14 O
19. g appliance manufacture The appliance is suitable only for installation in GB and IE and should be installed in accordance with the rules in force and only used in a suitably ventilated location In GB the installation must be carried out by a Gas Safe Registered Installer It must be carried out in accordance with the current and relevant requirements of legislation and guidance Where no specific instructions are given reference should be made to the relevant British Standard Code of Practice In IE the installation must be carried out by a competent Person and installed in accordance with the current edition of I S 813 Domestic Gas Installations the current Building Regulations and reference should be made to the current ETCI rules for electrical installation Incorrect installation could invalidate the warranty and may lead to prosecution 7212141 02 06 14 Introduction 7212141 02 06 14 1 5 2 Installer s Responsibility The installer is responsible for the installation and initial start up of the appliance The installer must adhere to the following instructions gt Read and follow the instructions given in the manuals provided with the appliance gt Carry out installation in compliance with the prevailing legislation and standards gt Ensure the system is flushed and inhibitor added gt Install the flue chimney system correctly ensuring it is operational and complies with prevailing legislatio
20. luding in any database in each case whether electronic mechanical recording or otherwise without the prior written permission of the copyright owner except for permitted fair dealing under Copyrights Designs and Patents Act 1988 Applications for the copyright owner s permission to reproduce or make other use of any part of this publication should be made giving details of the proposed use to the following address The Company Secretary Baxi Heating UK Limited Brooks House Coventry Road Warwick CV34 4LL Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety efficiency and performance Benchmark is managed and promoted by Heating and Hotwater Industry Council For more information visit www centralheating co uk 7212141 02 06 14 Contents Contents Vat 1 1 4 General 5 1 2 Additional Documentation 5 1 3 Symbols Used H 5 1 4 Abbreviations Glossary 6 1 5 6 1 5 4 Manufacturer s Liability 6 1 5 2 Installer s Responsibilit
21. n and standards regardless of location of the boiler s installation gt Only the installer should perform the initial start up and carry out any checks necessary gt Explain the installation to the user gt Complete the Benchmark Commissioning Checklist this is a condition of the warranty gt Warn the user of the obligation to check the appliance and maintain it in good working order p Give all the instruction manuals to the user 1 5 3 User s Responsibility To guarantee optimum operation of the installation you must observe the following instructions gt Read and observe the instructions given the manuals supplied with the appliance gt Seek the assistance of a qualified installer for the installation and initial commissioning p gt Ask the installer to explain the installation gt Have the required annual inspection and maintenance carried out by a qualified installer and ensure the Benchmark Service Record in the Installation Manual is completed this is a condition of the warranty gt Keep the manuals in good condition and near to the appliance This appliance must not be used by people with a lack of experience or knowledge unless they are supervised by someone familiar with the appliance or if they have been instructed on how to operate the appliance correctly Do not allow children to operate or play with the appliance EcoBlue System 2 2 1 Safety General Safety Instructions
22. not working The water pressure is too low lt 0 5 bar The temperature set point for the heating is too low No demand for heating No power supply The water pressure is too low lt 0 5 bar The boiler is indicating an error The gas pressure is too low Condensate drain blocked Solution Check that the boiler is being supplied with power Check fuses and the switches Check whether the gas valve is properly open If the property has a prepayment meter ensure it has sufficient credit Re pressurise the system Flow must be at least 2 5 litres per minute Increase the value with the CH temperature button or if a room thermostat is connected increase the temperature on the room thermostat Activate the heating mode Open the valves of all radiators connected to the system Check that the boiler is being supplied with power Check fuses and switches Check whether the gas isolation valve is properly open If the property has a prepayment meter ensure it has sufficient credit Re pressurise the system Increase the value with the CH temperature button or if a room thermostat is connected increase the temperature on the room thermostat Ensure that timers amp thermostats are calling for heat Check that the boiler is being supplied with power Check the fuses and switches Re pressurise the system Press the Reset button Correct the error if possible Check whether the gas i
23. ns Your installer will be able to offer advice EcoBlue System 6 44 Boiler Flow Temperature To increase or decrease the boiler temperature 1 Press 111 to increase the boiler flow temperature 2 Press wir to decrease the boiler flow temperature This sets the temperature at which the heated water flows L from the boiler The temperature of radiators and domestic hot water will depend upon the setting of various controls e g Thermostatic Radiator Valves cylinder thermostat Your installer will be able to recommend the optimum boiler temperature setting according to the controls fitted and your requirements FIM and are pressed together 2 will il be displayed Pressing either button again will scroll through the display and P26 amp P64 will be shown Press d R to return to normal display 6 1 2 Inactive Buttons 1 Both ily and mm are inactive unless an outdoor sensor is connected 6 1 3 On Off Selector Button 1 Press 1111 button until the Boiler mode symbol appears Boiler On mode N B If only W is displayed the boiler will not operate IEY See 6 1 1 to set the required temperature 6 4 4 Information Display 1 The table opposite shows information that can be displayed by pressing the 1 P button 2 Depending upon boiler model and any system controls connected to the appliance not all information codes will be displayed and some that are will not have
24. on This document is intended for use by competent persons All Gas Safe registered engineers carry an ID card with their licence number and a photograph You can check your engineer is registered by telephoning 0800 408 5500 or online at www gassaferegister co uk This manual is intended for the user of the Baxi EcoBlue System boiler If the appliance is sold or transferred or if the owner moves leaving the appliance behind you should ensure that the manual is kept with the appliance for consultation by the new owner and their installer The appliance is designed as a boiler for use in residential domestic environments on a governed meter supply only The selection of this boiler is entirely at the owner s risk If the appliance is used for purposes other than or in excess of these specifications the manufacturer will not accept any liability for resulting loss damage or injury The manufacturer will not accept any liability whatsoever for loss damage or injury arising as a result of failure to observe the instructions for use maintenance and installation of the appliance Various timers external controls etc are available as optional extras Full details are contained in the relevant sales literature In these instructions various danger levels are employed to draw the user s attention to particular information In so doing we wish to safeguard the user s safety prevent hazards and guarantee correct operation of the applianc
25. outed except by a qualified professional 7212141 02 06 14 43 Control Panel Description Boiler Information View Standby Reset Esc Description of the Product 4 Key to Controls 1 R Standby Reset Esc Button 1 Boiler Information View Button BBB 6 gt m mr m THESE BUTTONS INACTIVE except when an Boiler Flow outdoor sensor relay kit is connected On Off Selector Button Display showing all available characters 7212141 02 06 14 Increase CH Temperature Button wir Decrease CH Temperature Button Inactive Button Except when an outdoor sensor relay kit is connected Inactive Button On Off Selector Button Temperature Adjustment When Wiis displayed Boiler On the boiler will respond to timed Heating or Hot Water demand L N B If only jay is displayed the boiler will not operate Display Description 1 DHW CH OFF frost protection still enabled See Section 5 2 for information Indicates an error that prevents burner from igniting Error Not resettable by user Water pressure too low RI Indicates an error resettable by the user Generic error Burner lit DHW mode symbol will flash with demand 1111 Heating mode symbol will flash with demand Ne Units for temperature PSI Units for pressure bar EcoBlue Syst
26. peration 5 1 If it is anticipated that the boiler will not be used for a long period or the property is to be unoccupied it is recommended that the system drained if the electricity amp gas supplies are to be turned off Your installer will be able to offer advice 1 The boiler incorporates an integral frost protection feature that will operate in On mode and also when in standby mode 1 displayed 2 If the boiler temperature falls below 5 C then the boiler will operate until the water temperature has been raised 3 Further protection may be required for the system Consult your installer for details EcoBlue System 15 5 Operation 5 3 START Is there electricity to the boiler Is the display lit Make sure the gas YES YES supply is turned ON gt and check if other gas appliances are operating e g fire cooker If the property has a prepayment meter ensure it has sufficient credit NO Burner Flame is on If no gas consult your supplier Check electrical supply to boiler is switched on Indicates burner Operation Checking Procedure amp Basic Fault Identification Is the Burner Flame NO showing YES 101 Boiler operating satisfactorily gt YES Is the Room Thermostat if yes fitted set high enough Is the Timer ON calling for heat Is the Central Heating
27. rols 5mm Min In Operation Technical Specifications 345mm gt EcoBlue System 11 4 4 1 Serial Number User Label 4 2 12 Description of the Product Description of the Product General Description Label Boiler Control Flap Operating Principle EcoBlue System 1 The Baxi EcoBlue System boilers are fully automatic gas fired wall mounted condensing boilers They are room sealed and fan assisted and will serve central heating and stored domestic hot water 2 The boiler is set to give a maximum output of 12 model 12 kW 12 7 kW Condensing 15 model 15kW 15 9 kW Condensing 18 model 18 kW 19 kW Condensing 24 model 24 kW 25 4 kW Condensing 28 model 28 kW 29 6 kW Condensing 32 model 32 kW 33 8 kW Condensing 3 The boiler is factory set for use only on Natural Gas G20 4 The boiler model serial number and Gas Council number are also shown on the information label behind the boiler control flap Fig 1 This is for user reference Ey The boiler is set by use of the button see Section 6 1 4 2 1 In Operation 1 Whilst the boiler is in operation cooled flue gases are discharged through the flue gas discharge pipe This may appear as a cloud of steam which is normal 2 Condensed water is discharged from the boiler heat exchanger into a pipe the condensate drain This pipe must never be altered or re r
28. s Work from the lowest radiator in the property 6 Open the bleed vent with the key keeping a cloth pressed against the vent 7 Wait until water comes out of the bleed vent and then close AN WARNING The CH water in the radiators will still be hot 8 Switch the boiler on 9 After venting check that the water pressure in the system is still adequate ILZ If the water pressure is lower than 0 7 bar the water must be topped up If necessary repressurise the system recommended pressure between 1 and 2 bar 10 Reset the room thermostat to the desired temperature EcoBlue System 21 7 5 22 Maintenance Draining the System EcoBlue System 1 It may be necessary to drain the CH system if radiators need to be replaced or removed if there is a major water leak or if there is a risk of freezing Proceed as follows 1 Open the valves of all the radiators connected to the system 2 Switch off or disconnect the boiler s electrical isolation point fused spur 3 Wait until all the radiators are cold 4 Connect a drain hose to the lowest draining point Place the end of the hose in a drain or at a place where drained water will not cause any damage 5 Open the CH system drain valve Drain the system AN WARNING The CH water may still be hot 6 When water stops flowing from the draining point close the draining valve 057 See Sections 7 4 amp 7 5 for
29. solation valve is fully open Open the gas isolation valve Check drain especially any external runs in freezing temperatures 7212141 02 06 14 9 Decommissioning 9 1 Decommissioning Procedure 10 Disposal 10 1 Disposal Recycling 7212141 02 06 14 Decommissioning Disposal 9 10 AN CAUTION Only qualified professionals are authorised to work on the appliance and installation 1 If you the boiler needs to be decommissioned either temporarily or permanently the following should be performed e Switch off the boiler e Switch off the boiler s electrical connection e Close the boiler gas valve e Drain the CH system TS See section 7 6 Draining the Installation AN WARNING Removal and disposal of the boiler must be carried out by a qualified installer in accordance with local and national regulations EcoBlue System 25 11 26 Environmental 11 Environmental 11 1 Energy Saving EcoBlue System Tips on saving energy gt gt v Do not cover radiators Do not hang curtains in front of radiators Install reflective panels behind the radiators to prevent heat losses Insulate the pipes in rooms that are not heated cellars and lofts Install loft insulation amp double glazing Use draught excluders where necessary Upgrade any older boiler external controls Turn down room thermostats by 1 Close the radiators in rooms not in use Do not run hot
30. umber To ensure the highest level of customer service heateam will text to you your engineer appointment details if you provide a mobile phone number Following your engineer visit we will ask you to rate your level of satisfaction with our service via text message 7212141 02 06 14 5 7212141 02 06 14 EcoBlue System 29 5 30 EcoBlue System 7212141 02 06 14 5 7212141 02 06 14 EcoBlue System 31 All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject to our standard Conditions of Sale which are available on request BAXI A Trading Division of Baxi Heating UK Ltd 3879156 Brooks House Coventry Road Warwick CV34 4LL After Sales Service 0844 871 1525 Technical Enquiries 0844 871 1555 Website www baxi co uk e amp oe PART OF BDR THERMEA 7212141 02 06 14
31. y 7 1 5 3 User s Responsibility 7 Safety 8 2 1 General Safety INStructiOns 8 2 2 RecommendaloNS 9 2 2 1 Benchmark Commissioning Checklist 9 Technical Specifications Dba arn ceeds 10 3 1 Technical Dala 2 10 Description Of the Product creer eer cree tree eter teeeentteessteecssenconsenennsenensesnenseansnsesnnenenensnensneneenseesaneecstseessunsectunscensesenuneenaneees 12 4 1 General Description 12 4 2 Operating Principle 4 2 1 Operation 12 4 3 Control Panel Description 13 44 Standard Delivery 4 5 Accessories amp Options 4 5 1 Optional Extras Operation 5 1 SFU WV